ADDENDUM_08202019_CG805.pdf

PDF 337 KB Posted

Attached to
Explosive Ordnance Disposal Technical Facility, Picatinny Arsenal, New Jersey
Solicitation number
W912DS19R0021
Issued by

About this file

Drawing amendment 0004 - ADDENDUM_08202019_CG805

View the file

Other files

File Type Posted
ADDENDUM_08202019_21_13_26.01_64.pdf PDF
ADDENDUM_08202019_CU112.pdf PDF
ADDENDUM_08202019_CU101.pdf PDF
ADDENDUM_08202019_2FP501.pdf PDF
ADDENDUM_08202019_2FP001.pdf PDF
ADDENDUM_08202019_2FA101.pdf PDF
ADDENDUM_08202019_2FP101.pdf PDF
ADDENDUM_08202019_TOC_with_DELETION.PDF PDF
Amendment_0005.pdf PDF
ADDENDUM_08202019_21_13_13.00_10.pdf PDF
ADDENDUM_08202019_CU111.pdf PDF
ADDENDUM-08202019-CG701.pdf PDF
ADDENDUM_08202019_CG804.pdf PDF
ADDENDUM_08202019_CG802.pdf PDF
ADDENDUM_08202019_CG712.pdf PDF
ADDENDUM_08202019_CG710.pdf PDF
ADDENDUM_08202019_CG711.pdf PDF
ADDENDUM_08202019_2A112.pdf PDF
ADDENDUM_08202019_CG803.pdf PDF
Amendment_0004.pdf PDF
ADDENDUM_08072019_-_Munitions_Building_Door_Hardware_.pdf PDF
ADDENDUM_08072019_-_Drawings.pdf PDF
ADDENDUM_08072019_-C-002.pdf PDF
01_22_00.00_10_PRICE_AND_PAYMENT.pdf PDF
ADDENDUM_08072019_-_SPEC_08_34_59_ARMORY_DOORS.pdf PDF
Sign-in_Sheet_for_Site_Visit.pdf PDF
Amendment_0003.pdf PDF
Amendment_0002.pdf PDF
VisitorControlMap_20190227.pdf PDF
02_SITE_E.pdf PDF
01_GENERAL.pdf PDF
02_SITE_A2.pdf PDF
02_SITE_A1.pdf PDF
Amendment_0001.pdf PDF
02_SITE_C.pdf PDF
02_SITE_D.pdf PDF
05_MAGAZINES.pdf PDF
04_MUNITIONS.pdf PDF
02_SITE_B.pdf PDF
03_ROBOTICS.pdf PDF
EOD_RTA_Submittal_Register.pdf PDF
W912DS19R0021.pdf PDF
EOD_RTA_Drawing_Submittal.pdf PDF
2019-07-17_RTA_SUBMITTAL_EOD_Picatinny__-_FULL_SET.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STABILIZED CONSTRUCTION ENTRANCE

INLET PROTECTION DETAIL

"SUPER" SILT FENCE DETAIL

TYPICAL RIP RAP CHANNEL

NOTE:

PROVIDE AS SHOWN ON THE PLANS.

FILTER FABRIC OR

GRAVEL BEDDING

TRAPEZOIDAL

STANDARD RIP-RAP LINED CHANNELS

2'

3:1 MAX SIDE

SLOPE

S E

D I M

E N

T

A

N D

E

R O

S I O

N

C O

N T

R O

L

D

E T

A I L S

U S

A

R M

Y

C

O R

P S

O

F

E

N G

I N

E E

R S

J U

L Y

P E

O D

C

G d w g

CG805

W D

S D

X

J

L O

C K

M

S

O U

T H

M

M

A Y

E R

M

P

O E

A N

S I

D

RTA SUBMITTAL

P I C

A T

I N

A

S

E N

A L

N

W

J

R S

E Y

E X

P L O

S I V

E

O

R D

N A

N C

E

D

I S

P O

S A

L

E

O D

T E

C H

N O

L O

G

C

I L I T

Y

F Y

P

N

N E

W

Y

O R

K

D

I S

T R

I C

T

N E

W

Y

O R

K

N

W

R

K

U S

A

R M

Y

C

O R

P S

E

N G

I N

E E

R S

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

F I L E

N A

M E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

A

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C T

US Army Corps of Engineers

C A

T E

G O

C

D

E

D E

S C

R I P

T I O

N

P P r o j e c t s

C

A D

B

I M

S h e e t s C i v i l P

E O

D C

G d w g u g a m

A D

D E

N D

U M

AutoCAD SHX Text

SCALE: NO SCALE

AutoCAD SHX Text

NOTE: "SILTSACK" OR APPROVED EQUAL STORM SEWER INLET PROTECTION.

AutoCAD SHX Text

SCALE: NO SCALE

AutoCAD SHX Text

LENGTH OF STABILIZED CONSTRUCTION ENTRANCE

AutoCAD SHX Text

% SLOPE

AutoCAD SHX Text

LENGTH (L) FOR COARSE GRAINED SOIL

AutoCAD SHX Text

LENGTH (L) FOR FINE GRAINED SOIL

AutoCAD SHX Text 0 - 2%

AutoCAD SHX Text

50 FT

AutoCAD SHX Text

100 FT

AutoCAD SHX Text 2% - 5%

AutoCAD SHX Text

100 FT

AutoCAD SHX Text

200 FT

AutoCAD SHX Text > 5%

AutoCAD SHX Text ENTIRE SURFACE STABILIZED WITH FABC BASE COURSE SAP BY LOCAL ORDINANCE OR OTHER GOVERNING BODY.

AutoCAD SHX Text 25' R

AutoCAD SHX Text 25' R

AutoCAD SHX Text

EXISTING GROUND

AutoCAD SHX Text PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC R.O.W.

AutoCAD SHX Text

1 1/2" - 4" DIA. STONE

AutoCAD SHX Text

FILTER FABRIC

AutoCAD SHX Text ADDITIONAL LENGTH OR TOP DRESSING MAY BE REQUIRED BY THE DISTRICT AS CONDITIONS DEMAND.

AutoCAD SHX Text ALL SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY MUST BE REMOVED IMMEDIATELY.

AutoCAD SHX Text

BAG DETAIL

AutoCAD SHX Text

INSTALLATION DETAIL

AutoCAD SHX Text

INLET FILTER BAG

AutoCAD SHX Text

DUMP STRAPS

AutoCAD SHX Text

INSERT 1" REBAR FOR REMOVAL OF BAG FROM INLET

AutoCAD SHX Text

LUMBER

AutoCAD SHX Text

WIDTH=W

AutoCAD SHX Text

INLET GRATE

AutoCAD SHX Text

LENGTH=L

AutoCAD SHX Text

CURB OPENING

AutoCAD SHX Text

DEPTH=D

AutoCAD SHX Text

LUMBER

AutoCAD SHX Text

PROVIDE OVERFLOW SLOTS FOR FLOOD OVERFLOWS

AutoCAD SHX Text

DUMP STRAP (TYP.)

AutoCAD SHX Text

INSERT 1" REBAR FOR REMOVAL OF BAG FROM INLET

AutoCAD SHX Text

DUMP STRAPS (2 EACH)

AutoCAD SHX Text

EXPANSION RESTRAINT (1/4" NYLON ROPE, 2" FLAT WASHERS)

AutoCAD SHX Text

SCALE: NO SCALE

AutoCAD SHX Text

CHAIN LINK FENCING

AutoCAD SHX Text

EXISTING GROUND

AutoCAD SHX Text

FILTER CLOTH

AutoCAD SHX Text

EMBED FILTER CLOTH 6" MINIMUM INTO GROUND

AutoCAD SHX Text

16" MIN. 1ST LAYER FILTER CLOTH

AutoCAD SHX Text

2-1/2" DIA. GALVANIZED OR ALUMINUM POSTS

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

33" MIN. POST AND 2ND LAYER FILTER CLOTH

AutoCAD SHX Text

EXISTING GROUND

AutoCAD SHX Text

CHAIN LINK FENCE WITH ONE LAYER OF FILTER CLOTH

AutoCAD SHX Text

2-1/2" DIA. GALVANIZED OR ALUMINUM POSTS

AutoCAD SHX Text

33" MIN.

AutoCAD SHX Text

36" MIN.

AutoCAD SHX Text

6" MIN.

AutoCAD SHX Text

16" MIN.

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FENCE POSTS, MAX. 8 FT. O.C.

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

SCALE: NO SCALE

File details come from the government source that posted it.