ADDENDUM_08072019_-_Munitions_Building_Door_Hardware_.pdf
PDF 113 KB Posted
- Solicitation number
- W912DS19R0021
About this file
ADDENDUM_08072019_-_Munitions_Building_Door_Hardware
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MUNITIONS BUILDING
ADDENDUM 08/07/2019
Hardware Set No. B2-01 For use on mark/door #(s):
100A Each to have:
HARDWARE BY MANUFACTURER
Hardware Set No. B2-02
100B 100C 114A Each to have:
1 EA CONT. HINGE (A31031G) 224HD EPT 628 IVE
1 EA POWER TRANSFER EPT10 CON 689 VON
1 EA FINAL CORE (E09241L) 1C72 626 BES
1 EA ELEC PANIC HDWE (GRADE 1,
TYPE 1, FUNCTION 03)
RX-QEL-98-NL-CON-24VDC 626 VON
1 EA RIM CYLINDER (E09222) 80-116 626 SCH
1 EA CLOSER (C002 PT-4A, PT-4C, PT-
4D, PT-4F, PT-4G, PT-4H)
SC71A SS 689 FAL
1 EA GASKETING (R3E164) 429AA-S AA ZER
1 EA RAIN DRIP (R3Y976) 142AA AA ZER
1 EA THRESHOLD (J35100) 65A-223 A ZER
1 EA WIRE HARNESS CON-26P SCH
1 EA WIRE HARNESS CON-6W SCH
1 EA DOOR CONTACT (A153.25) 679-05 WD/HM AS REQ'D WHT SCE
1 EA POWER SUPPLY (ANSI/UL 294
FOR ACCESS CONTROL; ULC-
S318.)
PS902 900-2RS 120/240VAC VON
CARD READER BY OTHERS
DOORS REQUIRE SPECIAL 3/8 INCH UNDERCUT FOR ADA TYPE THRESHOLD.DESCRIPTION OF
OPERATION:PRESENTING VALID CREDENTIAL TO READER WILL RETRACT LATCH FOR
ACCESS.REQUEST TO EXIT SWITCH IS FOR USE BY ACCESS CONTROL CONTRACTOR.DOOR
POSITION SWITCH IS FOR USE BY ACCESS CONTROL CONTRACTOR.EMERGENCY ACCESS BY
MECHANICAL KEY OVERRIDE.FREE EGRESS AT ALL TIMES.
Hardware Set No. B2-03
101A Each to have:
1 EA CONT. HINGE (A31031G) 224HD 628 IVE
1 EA CONT. HINGE (A31031G) 224HD EPT 628 IVE
2 EA FLUSHBOLT (L04261) FB358/FB458 AS REQ'D 626 IVE
1 EA FINAL CORE (E09241L) 1C72 626 BES
1 EA ELEC PANIC HDWE (GRADE 1,
TYPE 3, FUNCTION 03)
RX-QEL-9875-NL-CON-
24VDC
626 VON
1 EA MORTISE CYLINDER (E09211) 80-110 XQ11-948 626 SCH
1 EA OH STOP & HOLDER (C08511) 79H 626 GLY
1 EA CLOSER (C002 PT-4A, PT-4C,
PT-4D, PT-4F, PT-4G, PT-4H)
SC71A SS 689 FAL
1 EA GASKETING (R3E164) 429AA-S AA ZER
1 EA RAIN DRIP (R3Y976) 142AA AA ZER
1 EA GASKETING (R3E734) 326AA-S AA ZER
1 EA WIRE HARNESS CON-6W SCH
1 EA WIRE HARNESS CON-26P SCH
2 EA DOOR CONTACT (A153.25) 679-05 WD/HM AS REQ'D WHT SCE
1 EA POWER SUPPLY (ANSI/UL 294
FOR ACCESS CONTROL; ULC-
S318.)
PS902 900-2RS 120/240VAC VON
CARD READER BY OTHERS
DOORS REQUIRE SPECIAL 3/8 INCH UNDERCUT FOR ADA TYPE THRESHOLD.
DESCRIPTION OF OPERATION:
PRESENTING VALID CREDENTIAL TO READER WILL RETRACT LATCH FOR ACCESS.
REQUEST TO EXIT SWITCH IS FOR USE BY ACCESS CONTROL CONTRACTOR.
DOOR POSITION SWITCHES ARE FOR USE BY ACCESS CONTROL CONTRACTOR.
EMERGENCY ACCESS BY MECHANICAL KEY OVERRIDE.
FREE EGRESS AT ALL TIMES.
Hardware Set No. B2-04
102A 103A 104A 105A 106A 108A 109A 110A Each to have:
1 EA CONT. HINGE (A31031G) 224HD 628 IVE
1 EA PANIC HDWE (GRADE 1, TYPE 1,
FUNCTION 01)
LD-98-EO 626 VON
1 EA CLOSER (C002 PT-4A, PT-4C, PT-
4D, PT-4F, PT-4G, PT-4H)
SC71A SS 689 FAL
1 EA RAIN DRIP (R3Y976) 142AA AA ZER
1 EA GASKETING (R3E164) 429AA-S AA ZER
1 EA THRESHOLD (J35100) 65A-223 A ZER
1 EA DOOR CONTACT (A153.25) 679-05 WD/HM AS REQ'D WHT SCE
DOORS REQUIRE SPECIAL 3/8 INCH UNDERCUT FOR ADA TYPE THRESHOLD.
DESCRIPTION OF OPERATION:
DOOR POSITION SWITCH IS FOR USE BY ACCESS CONTROL CONTRACTOR.
Addendum 08/07/2019*****************************************************************
Hardware Set No. B2-05 For use on mark/door #(s):
107A
VAULT DOOR HARDWARE WILL BE PER MANUFACTURER AS SPECIFIED IN SECTION 08 34
59 ARMORY DOORS
***************************************************************** Addendum 08/07/2019
Hardware Set No. B2-06
108B 109B 110B Each to have:
3 EA HINGE (A8111) 5BB1HW 4.5 X 4.5 652 IVE
1 EA FINAL CORE (E09241L) 1C72 626 BES
1 EA CLASSROOM LOCK (F05) L9070BDC 17A 626 SCH
1 EA CLOSER (C001/C002/C004 PT-4A,
PT-4C, PT-4D, PT-4F, PT-4H)
SC71A REG ARM MOUNT 689 FAL
1 EA WALL STOP (L52101) WS406/407CVX 630 IVE
Hardware Set No. B2-07
111A 116A 116B Each to have:
1 EA CONT. HINGE (A31031G) 224HD 628 IVE
1 EA STOREROOM LOCK (F07) L9080BDC 17A 626 SCH
1 EA FINAL CORE (E09241L) 1C72 626 BES
1 EA CLOSER (C006 PT-4A, PT-4C, PT-
4D, PT-4F, PT-4G, PT-4H)
SC71A SSHO 689 FAL
1 EA RAIN DRIP (R3Y976) 142AA AA ZER
1 EA GASKETING (R3E164) 429AA-S AA ZER
1 EA THRESHOLD (J35100) 65A-223 A ZER
1 EA DOOR CONTACT (A153.25) 679-05 WD/HM AS REQ'D WHT SCE
DOORS REQUIRE SPECIAL 3/8 INCH UNDERCUT FOR ADA TYPE THRESHOLD.
DESCRIPTION OF OPERATION:
DOOR POSITION SWITCH IS FOR USE BY ACCESS CONTROL CONTRACTOR.
Hardware Set No. B2-08
112A 115A Each to have:
3 EA HINGE (A8112) 5BB1 4.5 X 4.5 652 IVE
1 EA FINAL CORE (E09241L) 1C72 626 BES
1 EA STOREROOM LOCK (F07) L9080BDC 17A 626 SCH
1 EA CLOSER (C002 PT-4A, PT-4C, PT-4D,
PT-4F, PT-4H)
SC71A HDPA 689 FAL
Hardware Set No. B2-09
113A Each to have:
3 EA HINGE (A8111) 5BB1HW 4.5 X 4.5 652 IVE
1 EA PRIVACY LOCK (F22) L9040 17A L583-363 L283-722 626 SCH
1 EA CLOSER (C001/C002/C004 PT-
4A, PT-4C, PT-4D, PT-4F, PT-4H)
SC71A REG ARM MOUNT 689 FAL