04_MUNITIONS.pdf
PDF 23 MB Posted
- Solicitation number
- W912DS19R0021
About this file
Drawings 04 Munitions
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-001
D D
IC
K
E Y
G E
N E
R A
L N
O T
E S
A N
D D
E S
IG
N
C R
IT
E
R
IA
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-0
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
GENERAL NOTES
I. GENERAL
A. THESE GENERAL NOTES PRESENT AND/OR SUMMARIZE KEY PROJECT
INFORMATION FOR THE READER'S CONVENIENCE. SEE ALSO INDIVIDUAL
PLAN NOTES AND PROJECT SPECIFICATIONS FOR FURTHER DETAILS AND
REQUIREMENTS.
B. ALL REFERENCES TO REFERENCE STANDARDS HEREIN ARE TO MOST
RECENT ISSUE IN EFFECT AS OF THE DATE OF THESE DOCUMENTS,
UNLESS NOTED OTHERWISE IN PROJECT SPECIFICATIONS OR ON THE
PLANS.
C. ELEVATIONS. ALL ELEVATIONS ARE REFERENCED TO FINISHED FLOOR EL.
100'-0". ALL ELEVATIONS SHOWN ON PLANS ARE REFERENCED TO THE
SITE ELEVATION DATUM SHOWN ON FOUNDATION PLANS UNLESS NOTED
OTHERWISE.
D. SUBMIT SHOP DRAWINGS, PROJECT DATA AND SAMPLES AS SPECIFIED IN
PROJECT SPECIFICATIONS SECTION 01 33 00.
1. IDENTIFY PROMINENTLY ON DRAWINGS EACH AND ALL RESUBMITTALS
BY NUMBER.
2. IDENTIFY ANY CHANGES WHICH HAVE BEEN MADE OTHER THAN THOSE
REQUESTED BY THE CONTRACTING OFFICER.
3. SUBMITTALS FAILING TO CONFORM TO THE ABOVE WILL BE RETURNED
FOR RESUBMITTAL.
E. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE
AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S
SOLE RESPONSIBILITY TO DETERMINE THE ERECTION PROCEDURE AND
SEQUENCE, AND TO ENSURE THE SAFETY AND STABILITY OF THE BUILDING
AND ITS COMPONENT PARTS DURING ERECTION. ALL NECESSARY
TEMPORARY BRACING AND TIE-DOWNS REQUIRED TO STABILIZE AND
SUPPORT THE STRUCTURE DURING ALL CONSTRUCTION PHASES SHALL BE
FURNISHED AND INSTALLED BY THE CONTRACTOR. SUCH MATERIAL SHALL
REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE
PROJECT. IF REQUIRED, TEMPORARY BRACING AND TIE-DOWNS SHALL BE
DESIGNED BY A LICENSED ENGINEER EMPLOYED BY THE CONTRACTOR.
F. CONSTRUCTION LOADS IMPOSED ON STRUCTURAL MEMBERS SHALL NOT
EXCEED THE DESIGN CAPACITY OF THE STRUCTURE AT THE TIME SUCH
LOADS ARE IMPOSED.
G. ALL DIMENSIONS OF EXISTING CONDITIONS SHALL BE VERIFIED PRIOR TO
COMMENCING WORK. DISCREPANCIES BETWEEN EXISTING CONDITIONS OR
BETWEEN THE DRAWINGS AND SPECIFICATIONS SHALL BE COMMUNICATED
TO THE CONTRACTING OFFICER.
H. WORK THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER
DRAWINGS. EACH DISCIPLINE'S DRAWINGS MAY NOT BE CONCLUSIVE.
VERIFY ALL DRAWINGS FOR TOTAL CONSTRUCTION.
I. ALL SECTIONS, DETAILS, MATERIALS, AND METHODS SHOWN AND/OR
NOTED ON ANY SHEET SHALL APPLY TO ALL OTHER SIMILAR LOCATIONS,
U.N.O.
II. DESIGN CRITERIA
A. BUILDING CODES AND DESIGN REFERENCES
2015 INTERNATIONAL BUILDING CODE
ASCE 7-10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES.
UFC 4-010-01, MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS
OCCUPANCY LEVEL - LOW OCCUPANCY
B. SUPERIMPOSED DESIGN LOADS
1. DEAD LOADS
ROOF DEAD LOAD - 24 psf MIN. ROOF DEAD LOAD - 11.0 psf
2. LIVE LOADS
ROOF LIVE LOAD - 20 psf FLOOR SLAB - 150 psf
3. SNOW: GROUND SNOW LOAD = 35 psf.
A. EXPOSURE FACTOR, Ce = 1.0 (EXPOSURE C, PARTIALLY EXPOSED) B. SLOPE FACTOR, Cs = 1.0 C. THERMAL FACTOR, Ct = 1.0
D. IMPORTANCE FACTOR = 1.1
E. FLAT ROOF SNOW LOAD, Pf = 30 psf F. SLOPED ROOF SNOW LOAD = 30 psf
G. DRIFT LOADS - REFER TO SNOW LOADING DIAGRAM
4. WIND: (RISK CATEGORY III)
A. ULTIMATE DESIGN WIND SPEED, Vult = 120 MPH B. NOMINAL DESIGN WIND SPEED, Vasd = 93 MPH
C. EXPOSURE CATEGORY - C
D. INTERNAL PRESSURE COEFF., GCpi = +/-0.18
5. SEISMIC
A. RISK CATEGORY III, IMPORTANCE FACTOR =1.25
B. MAPPED SPECTRAL RESPONSE ACCELERATIONS
Ss = 0.24g S1 = 0.07g
C. SITE CLASSIFICATION - D
D. DESIGN SPECTRAL RESPONSE ACCELERATIONS
SDS = 0.26g SD1 = 0.11g
E. SEISMIC DESIGN CATEGORY - B
F. RESPONSE MOD. FACTOR, R, AND SEISMIC RESPONSE COEFF., C :
BEARING WALLS SYSTEMS, ORDINARY REINFORCED CONCRETE
SHEAR WALLS, R = 4.0, Cs = 0.08
G. DESIGN SEISMIC BASE SHEAR = 171.2 kips
H. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
6. FUTURE EXPANSION: NO PROVISION FOR FUTURE EXPANSION HAS
BEEN MADE THAT WILL IMPACT DESIGN PROVISIONS OF STRUCTURES
AND FOUNDATIONS UNDER THIS CONTRACT.
C. FOUNDATIONS
1. ALLOWABLE BEARING PRESSURE
SPREAD AND CONTINUOUS FOOTINGS - 3,000 psf
2. FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE RECOMMENDATIONS
OF THE GEOTECHNICAL EXPLORATION REPORT BY CEMS ENGINEERING
DATED JUNE 25, 2018. REPORT IS AVAILABLE FOR INFORMATION ONLY UPON
REQUEST FROM THE CONTRACTING OFFICER.
3. ALL OPEN FOUNDATION EXCAVATIONS TO BE INSPECTED AND APPROVED BY
THE CONTRACTOR'S LICENSED GEOTECHNICAL ENGINEER PRIOR TO
PLACING CONCRETE. UNSATISFACTORY MATERIALS ENCOUNTERED SHALL
BE EXCAVATED AND REPLACED WITH SATISFACTORY MATERIALS. REFER TO
SHEET CG101 FOR OVER-EXCAVATION REQUIREMENTS.
III. TESTING AND INSPECTION
A. FOUNDATIONS AND EARTHWORK. GEOTECHNICAL ENGINEER/TESTING
LABORATORY SHALL BE ENGAGED FOR QUALITY CONTROL AND VERIFICATION.
SEE SPECS. ALL OPEN FOUNDATION EXCAVATIONS SHALL BE INSPECTED
AND APPROVED BY THE CONTRACTOR'S LICENSED GEOTECHNICAL
ENGINEER PRIOR TO CONCRETE PLACEMENT.
B. MATERIALS AND PROCEDURES. TESTING LABORATORY SHALL BE ENGAGED
FOR MATERIAL TESTING AND INSPECTION. SEE SPECS.
C. SPECIAL INSPECTOR. A SPECIAL INSPECTOR WILL BE ENGAGED BY THE
CONTRACTOR TO INSPECT ELEMENTS AS REQUIRED. SEE SPECIFICATIONS.
IV. EARTHWORK
A. SITE PREPARATION. REFER TO CG112 FOR GRADING AND EARTHWORK
REQUIREMENTS. REFER TO SPECIFICATIONS.
B. STRUCTURAL FILLS. FILL MATERIAL COMPACTED IN 8" LIFTS
FOR HEAVY EQUIPMENT COMPACTORS, 4" LIFTS FOR HAND-OPERATED
EQUIPMENT. SEE SPECIFICATIONS FOR ACCEPTABLE FILL MATERIAL.
1. SUBGRADE UNDER BUILDING FOUNDATIONS: MINIMUM DENSITY 95% ASTM
D1557.
2. SUBGRADE UNDER SLABS-ON-GRADE: MINIMUM DENSITY 95% ASTM
D1557.
3. GRANULAR SUBBASE UNDER SLAB-ON-GRADE: VAPOR BARRIER ON LAYER OF
COMPACTED CRUSHED STONE. A THIN LAYER OF APPROX. 1/2" OF FINE
GRADED MATERIAL SHALL BE ROLLED OR COMPACTED OVER THE CRUSHED
STONE TO PREVENT PUNCTURE OF THE VAPOR BARRIER. 1/2" LAYER SHALL
BE PART OF THE CRUSHED STONE THICKNESS.
4. BACKFILL WITHIN 3' OF RETAINING WALLS SHALL BE PLACED IN LOOSE
LIFTS NOT TO EXCEED 4" AND SHALL BE COMPACTED WITH HAND-
OPERATED EQUIPMENT. AVOID OVER COMPACTION, HEAVY EQUIPMENT
SHALL NOT BE PERMITTED WITHIN 10' OF WALLS.
5. EXCEPT FOR RETAINING WALLS, FOUNDATION WALLS HAVE NOT BEEN
DESIGNED TO RESIST LATERAL LOADS. BACKFILLING SHALL BE PERFORMED
SUCH THAT THE ELEVATION OF BACKFILL ON BOTH SIDES OF THE
FOUNDATION WALL IS ESSENTIALLY EQUAL (NOT TO EXCEED A
DIFFERENCE OF 2 FT) TO AVOID UNBALANCED LOADS.
6. GROUNDWATER LEVEL MAY BE ENCOUNTERED AT THE PROPOSED
FOUNDATION ELEVATIONS. NO FOOTINGS OR SLABS SHALL BE PLACED ON
OR AGAINST SUB-GRADE CONTAINING FREE WATER OR FROZEN SOILS.
SHOULD WATER ENTER A FOOTING EXCAVATION AFTER SUB-GRADE
APPROVAL, THE SUB-GRADE SHALL BE RE-INSPECTED BY THE TESTING
LABORATORY AFTER REMOVAL OF WATER. CONTRACTOR SHALL FURNISH
ALL REQUIRED DEWATERING EQUIPMENT TO MAINTAIN A DRY EXCAVATION
UNTIL BACKFILL IS COMPLETE.
C. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
V. CAST-IN-PLACE REINFORCED CONCRETE
A. DESIGN CODE. ACI 318 - STRENGTH DESIGN. REFERENCE STANDARD:
ACI 301. CONTRACTOR TO MAINTAIN COPY AT JOB SITE.
B. MIX DESIGN SHALL BE DOCUMENTED IN ACCORDANCE WITH SECTION
03 30 00.00 10 OF THE PROJECT SPECS AND ACI 301, CHAPTER 3
"PROPORTIONING". MIX DESIGNS WHICH ARE SUBMITTED WITHOUT THE
REQUIRED DOCUMENTATION WILL BE REJECTED. FIELD SLUMPS
RECORDED AT JOB SITE SHALL NOT EXCEED THE SLUMP ESTABLISHED
FOR THE MIX DESIGN.
C. CONCRETE. REFER TO SPECS.
1. ALL CONCRETE FOR BUILDING CONSTRUCTION SHALL HAVE A COMPRESSIVE
STRENGTH OF 4500 psi AT 28 DAYS.
2. REFER TO SPECIFICATIONS FOR AIR-ENTRAINMENT.
D. FORMWORK
1. SEE SPECS.
2. KEYS INDICATED ARE TO BE 2" x 4" NOMINAL CONTINUOUS, UNO.
3. RUSTICATION STRIPS, CHAMFERS, DRIPS, MISC. EMBEDS, ETC. SEE
PLANS AND/OR ARCHITECTURAL DRAWINGS.
4. OPENINGS FOR MEP TRADES. ALL HOLES FOR OTHER TRADES WHICH
MUST BE CUT OR FORMED AND WHICH ARE NOT SHOWN ON THE
STRUCTURAL DESIGN(S) DRAWINGS SHALL BE SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW AND APPROVAL.
E. REINFORCEMENT
1. REINFORCING BARS. DEFORMED, GRADE 60, ASTM A615.
ASTM A706 WHERE SPECIFIED AND FOR WELDING APPLICATIONS.
A. FABRICATION: ACI SP-66 "ACI DETAILING MANUAL"
2. WELDED SMOOTH WIRE FABRIC - ASTM A185. FLAT SHEETS.
3. WELDING - ACI 301, SECTION 3.2.2.2.
4. CORNER BARS. PROVIDE CORNER BARS SAME SIZE AND SPACING AS
HORIZONTAL REINFORCEMENT AT INTERSECTIONS OF ALL WALLS AND
WALL FOUNDATIONS.
5. SPLICES. CONTINUOUS REINF. BARS INCLUDING CORNER BARS SHALL
BE LAPPED THE LENGTH SHOWN IN THE DEVELOPMENT / LAP SPLICE
TABLE SHOWN ON THE DESIGN DRAWINGS.
6. MINIMUM COVER FOR PROTECTION TYPICAL, U.N.O.
A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3"
B. FORMED SURFACE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS - 2"
#5 AND SMALLER - 1 3/4"
C. STRUCTURAL SLABS AND WALLS NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND - 3/4"
D. BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS,
AND SPIRALS NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND - 1 1/2"
7. HOOKS INDICATED ARE ACI/CRSI STANDARD 90 DEG. OR 180 DEG.
HOOKS. BAR LENGTHS SHOWN ARE OUT-TO-OUT AND DO NOT INCLUDE
HOOK LENGTH.
F. SLAB & WALL OPENINGS. COORDINATE WITH MECHANICAL, PLUMBING AND
ELECTRICAL TRADES. FIELD REQUIREMENTS NOT SHOWN ON STRUCTURAL
PLANS MUST BE APPROVED BY THE CONTRACTING OFFICER. ANY
STRENGTHENING OR ADDITIONAL REINFORCEMENT REQUIRED SHALL
BE FURNISHED BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO
THE GOVERNMENT. PLUMBING SLOTS ARE TO BE FILLED WITH CONCRETE TO
SAME THICKNESS AS SLAB OR WALL AFTER PIPING HAS BEEN INSTALLED.
SEE TYPICAL PENETRATION DETAILS FOR REQUIREMENTS.
G. EMBEDDED PIPES OR CONDUIT. MAXIMUM DIAMETER - 1/3 x SLAB OR
WALL THICKNESS, SPACED MINIMUM OF 3 DIAMETERS ON CENTER.
H. GROUT. HIGH STRENGTH, NON-SHRINK STRUCTURAL GROUT. SEE SPECS.
I. CONCRETE FINISHES. SEE SPECS.
1. FORMED SURFACES:
A. PAINTED OR EXPOSED TO VIEW: CLASS A
B. INTERIOR PIT WALLS: CLASS B
C. CONCEALED OR AS NOTED ON PLANS: CLASS C
2. FLATWORK SURFACES:
A. INTERIOR SLABS EXPOSED TO VIEW: TROWELED WITH SURFACE
TREATMENT
B. INTERIOR SLABS TILED OR CARPETED: TROWELED
C. EXTERIOR STAIRS, STOOPS OR RAMPS: BROOMED
D. SIDEWALKS, PAVEMENTS: REFER TO CIVIL DRAWINGS AND
SPECIFICATIONS.
J. CURING AND PROTECTION. SEE SPECS.
K. SLABS ON GRADE
1. CONTRACTION JOINTS SHALL BE PLACED AS SHOWN ON PLANS.
SLAB CONSTRUCTION JOINTS MAY BE LOCATED AT CONTRACTION
JOINT LOCATIONS AT THE CONTRACTOR'S OPTION.
2. SEE CONTROL JOINT AND CONSTRUCTION JOINT DETAILS. JOINT
MAXIMUM SPACING IS 20'-0".
3. FILL SAWED CONTRACTION JOINTS AND EXPANSION JOINTS IN SLABS
WITH JOINT SEALANT.
L. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
VI. CONCRETE MASONRY
A. DESIGN CRITERIA. ACI 530
B. CONCRETE MASONRY UNITS:
1. HOLLOW UNITS: ASTM C90, NORMAL WEIGHT.
2. CONCRETE BUILDING BRICK: ASTM C55.
C. DESIGN F'm = 1,500 psi
D. MORTAR. ASTM C270, TYPE S (1800 psi). MASONRY CEMENT SHALL NOT
BE USED FOR REINFORCED CONCRETE MASONRY CONSTRUCTION.
E. GROUT. ASTM C476 (2000 psi). SEE SPECS FOR GROUTING POUR
HEIGHT, CLEAR CELL DIMENSIONS, AND CLEANOUT REQUIREMENTS.
F. REINFORCEMENT.
1. HORIZONTAL JOINTS: LADDER TYPE JOINT REINFORCING SHALL BE
USED. SEE SPECS.
2. VERTICAL AND HORIZONTAL REINFORCEMENT: ASTM A615, GRADE 60.
3. HORIZONTAL BOND BEAM REINFORCEMENT: (2) #5 BARS FOR WALLS
WITH 1 VERTICAL BAR; (1) #5 FOR WALLS WITH 2 VERTICAL BARS.
G. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
VII. STRUCTURAL STEEL
A. DESIGN, FABRICATION, AND ERECTION. AISC SPEC., FOR THE DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS.
B. TYPE OF CONSTRUCTION. SIMPLE TYPE PR
C. GRADE STEEL. WIDE FLANGE SHAPES - ASTM A992 (GRADE 50)
CHANNELS, ANGLES, AND MISC. SHAPES - ASTM A36
TUBE (HSS) SHAPES - ASTM A500, GRADE B (46 ksi MIN. YIELD STRENGTH).
D. CONNECTIONS. AISC MANUAL STANDARD CONNECTIONS UNLESS NOTED.
1. HIGH-STRENGTH BOLTS: ASTM F3125, GRADE A325 BEARING TYPE
INSTALLED IN CONFORMANCE WITH "SPECIFICATIONS FOR STRUCTURAL
JOINTS USING ASTM A325 OR A490 BOLTS", RESEARCH COUNCIL ON
RIVETED AND BOLTED STRUCTURAL JOINTS. UNO, STANDARD AISC
"USUAL GAGE" DIMENSIONS SHALL BE USED FOR LOCATING HOLES FOR
BOLTS, EXPANSION ANCHORS, ETC. IN ALL ANGLES, BEAM FLANGES, ETC.
2. WELDS: AWS D1.1, SERIES E70XX. ALL WELDS SHALL BE SUBJECT TO
INSPECTION AND NONDESTRUCTIVE EXAMINATION AS REQUIRED IN
SPECIFICATIONS. WHERE WELD SIZE IS NOT INDICATED ON THE
DRAWINGS, USE MINIMUM SIZE FOR PREQUALIFIED JOINTS PER AWS
D1.1.
3. ANCHOR RODS: ANCHOR RODS SHALL CONFORM TO ASTM F1554,
GRADE 36, AS INDICATED.
4. SIMPLE SHEAR CONNECTIONS: STEEL FABRICATOR SHALL DESIGN
BEAM CONNECTIONS FOR 50% OF THE UNIFORM LOAD CAPACITY OF
THE BEAM, UNLESS NOTED OTHERWISE.
E. TOLERANCES. AISC CODE OF STANDARD PRACTICE 2010, SECTION 6.4,
7.12, AND 7.13.
F. CAMBER. PROVIDE POSITIVE CAMBER AS NOTED ON PLANS. WHERE NO
CAMBER IS NOTED, RESIDUAL MILL CAMBER IS TO BE UPWARDS.
G. ROOF OPENINGS. VERIFY SIZE AND LOCATION OF REQUIRED
OPENINGS WITH MECHANICAL, PLUMBING, OR OTHER TRADES AS
NECESSARY TO ASSURE CORRECT FRAMING AND SUBMIT ON SHOP
DRAWINGS. PROVIDE SUB-SUPPORT AS REQUIRED FOR DECK CLOSURES
TYPICAL, INCLUDING AT COLUMNS. COORDINATE WITH DECK SUPPLIER.
H. SHOP DRAWINGS. SUBMIT ERECTION AND FABRICATION
SHOP DRAWINGS, SEE SPECS.
I. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
VIII. ADHESIVE AND EXPANSION ANCHORS
A. ADHESIVE ANCHORS SHALL CONSIST OF AN EQUAL TWO-COMPONENT
STRUCTURAL GRADE EPOXY INJECTION MATERIAL CONFORMING TO ASTM
C881. ROD MATERIAL SHALL MEET MIN. MATERIAL SPECIFICATIONS OF
ASTM A193, GRADE B7 OR APPROVED EQUAL.
B. REINFORCING BAR ANCHORS SHALL BE DEFORMED, GRADE 60, ASTM A615.
C. ADHESIVE ANCHORS SHALL MEET THE MINIMUM MATERIAL
SPECIFICATIONS OF ASTM A193, GRADE B7 OR APPROVED EQUAL.
EXPANSION ANCHORS SHALL BE GALVANIZED, CARBON STEEL.
D. ANCHORAGE SYSTEMS SHALL BE APPROVED BY THE CONTRACTING OFFICER.
E. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S PRINTED
LITERATURE AND SHALL INCLUDE THE BRUSHING AND CLEANING OF DRILLED
HOLES WITH COMPRESSED AIR. INSTALLERS SHALL BE TRAINED BY THE
MANUFACTURER'S REPRESENTATIVE. EMBEDMENT DEPTH SHALL BE AS
INDICATED ON THE STRUCTURAL DRAWINGS.
F. CONTRACTOR SHALL TAKE PRECAUTIONS NECESSARY DURING THE
DRILLING PROCESS TO AVOID DAMAGING EXISTING REINFORCEMENT.
ABANDON HOLES THAT INTERFERE WITH REINFORCEMENT, HAVE
INCORRECT DIAMETER OR SPALLING DAMAGE, AND FILL WITH GROUT.
DRILL HOLES AS REQUIRED.
G. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-002
D D
IC
K
E Y
G E
N E
R A
L N
O T
E S
A N
D D
E S
IG
N
C R
IT
E
R
IA
C O
N T
'D
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-0
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
GENERAL NOTES CONT'D
IX. METAL ROOF DECK
A. DESIGN, FABRICATION, & ERECTION. STEEL DECK INSTITUTE (SDI) MANUAL
OF CONSTRUCTION WITH STEEL DECK
B. MATERIAL. ASTM A653 TYPE SS (33 ksi MIN. YIELD STRENGTH)
C. METAL ROOF DECK
1 1/2" DEEP, 0.0474" THICK (18 GAGE) TYPE B WIDE RIB
WITH THE FOLLOWING MINIMUM SECTION PROPERTIES:
Ix = 0.289 in4/ft; S(+) = 0.318 in3/ft; I(-) = 0.295 in3/ft; S(-) = 0.327 in3/ft
D. INSTALLATION.
1. WHERE POSSIBLE, EXTEND OVER 3 OR MORE SUPPORTS.
DECK ATTACHMENTS SHALL BE IN ACCORDANCE WITH SDI SPECS AND
SHALL BE ADEQUATELY SHOWN ON DECK SHOP DRAWINGS FOR FIELD
INSTALLATION. ANCHOR TO RESIST THE NET UPLIFT PRESSURE AS SHOWN
ON THE PLANS.
2. DECK ATTACHMENT FOR 1.5B18 DECK SHALL BE WITH #12 TEK SCREWS
ON 36/7 PATTERN WITH #10 TEK SCREW SIDELAP FASTENERS AT 12" OC MAX.
3. OTHER MECHANICAL FASTENERS OR WELDS ON A PATTERN PRODUCING
STRENGTH AND STIFFNESS AT LEAST EQUAL TO THE ATTACHMENT SHOWN
MAY BE SUBMITTED FOR APPROVAL. WELDED SIDELAPS NOT PERMITTED.
E. ACCESSORIES. RIDGE, HIP, AND VALLEY PLATES ATTACHED
DIRECTLY TO STEEL DECK INCLUDED. GAGE TO MATCH ROOF DECK.
F. FINISH. G90 GALVANIZED
G. SHOP DRAWINGS. SUBMIT SHOP DRAWINGS.
H. SPECIAL INSPECTION. REFER TO SPECIFICATIONS.
X. OPEN-WEB STEEL JOISTS
A. DESIGN, FABRICATION, AND USE. SJI SPECS.
B. DETAILS. JOISTS TO BE WELDED OR BOLTED TO SUPPORTS. REFER TO
SECTIONS AND DETAILS FOR JOIST SEAT DEPTHS. EXTEND BOTTOM CHORD
OF JOIST TO COLUMN ON COLUMN LINES. PROVIDE VERTICAL STABILIZER
PLATE TO RECEIVE BOTTOM CHORD.
C. PAINT. PRIME AND PAINT IN ACCORDANCE WITH SPECS.
D. CONCENTRATED LOADS. ATTACH IN SUCH A MANNER OR AT SUCH AS
LOCATION (I.E. PANEL POINTS) SO THAT LOCAL BENDING IS NOT INDUCED
IN THE CHORDS EXCEPT AS INDICATED. FOR ALL CONCENTRATED LOADS
NOT OCCURRING AT JOIST PANEL POINTS, AN EXTRA WEB MEMBER MUST
BE FIELD APPLIED.
E. BRIDGING AND/OR DIAGONAL BRACING TO BE COLLINEAR WHERE EXPOSED
TO VIEW. ANY BRIDGING SHOWN ON PLANS IS A MINIMUM REQUIREMENT.
ACTUAL BRIDGING REQUIREMENTS SHALL BE DETERMINED BY THE JOIST
SUPPLIER AS RECOMMENDED BY THE SJI.
F. JOIST SEATS TO BE DESIGNED FOR ROLLOVER FORCE OF 600 LBS.
G. SUBMIT SHOP DRAWINGS INCLUDING SNOW LOAD, WIND UPLIFT, AND
SPECIAL JOIST DESIGN CALCULATIONS. SEE SPECS.
ARCH- ARCHITECT(URAL)
BO- BOTTOM OF...
BRG- BEARING
CJ- CONTROL JOINT
CL- CENTERLINE
CLR- CLEAR
COL- COLUMN
CONC- CONCRETE
CONT- CONTINUOUS
CONST- CONSTRUCTION
DIA- DIAMETER
DIAG- DIAGONAL
EA- EACH
EF- EACH FACE
EL- ELEVATION
EQ- EQUAL
EW- EACH WAY
EXP- EXPANSION
FF- FINISHED FLOOR
FTG- FOOTING
HORIZ- HORIZONTAL
JBE - JOIST BEARING ELEVATION
JT- JOINT
LLB- LONG LEG BACK TO BACK
LLH- LONG LEG HORIZONTAL
LLV- LONG LEG VERTICAL
MAT'L- MATERIAL
MAX- MAXIMUM
MCJ- MASONRY CONTROL JOINT
MECH- MECHANICAL
MFR- MANUFACTURER
MIN- MINIMUM
NTS- NOT TO SCALE
OC- ON CENTER
OPH- OPPOSITE HAND
PL- PLATE
REINF- REINFORCING
REQ'D- REQUIRED
SIM- SIMILAR
STD- STANDARD
THRU- THROUGH
T&B- TOP AND BOTTOM
TO- TOP OF...
TYP- TYPICAL
UNO- UNLESS NOTED OTHERWISE
VERT- VERTICAL
w/- WITH
WP- WORKING POINT
ABBREVIATIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A
2S-201
2S-201
2S-201
2S-201
2S-202
155' - 0"
116' - 5 3/4"
3' - 4 1/2" 2' - 1 3/4"
15' - 0"
9 3/4"
4' - 4 1/4" 12' - 10"
/4
/2
/2
/2
/4
/4
/2
/2
/2
/2
/2
/2
/2
/2
/2
/4
A
2S-302
B
2S-302
C
2S-302
D
2S-302
1 2 3 4 5 6
A
A
2S-302
A
2S-302
A
2S-302
B
2S-302
B
2S-302
26' - 6" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 23' - 0" 18' - 6"
11' - 4" 3' - 4"
1' - 8"
3' - 4" 12' - 2" 6' - 0" 8' - 0" 9' - 0" 6' - 0" 11' - 0" 4' - 0" 6' - 0" 5' - 0" 9' - 6" 6' - 0" 10' - 6" 7' - 0" 6' - 0" 2' - 0" 8' - 0"
10' - 3 3/4" 6' - 4 1/2" 18' - 1 1/2"
3' - 4 1/2"
19' - 7 1/2"
3' - 4 1/2"
17' - 1 1/2"
3' - 4 1/2"
17' - 1 1/2"
3' - 4 1/2"
21' - 7 1/2"
3' - 4 1/2"
4' - 7 1/2"
3' - 4 1/2"
19' - 9 3/4"
11' - 8" 5' - 0" 9' - 4"
2S-202EL = 94' - 3"
TO SLAB
E
2S-302
N 766,704.31 E 477,580.16
N 766,674.93 E 477,632.47
CONT. FOOTING (TYP)
A
2S-303
6' - 2"
10" 3' - 4" 1' - 10"
FDN DRAIN,
REFER TO
CIVIL
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-110
D D
IC
K
E Y
F O
U N
D A
T
IO
N P
L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-1
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 1/8" = 1'-0"
FOUNDATION PLAN
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. REFER TO 2S-001 FOR GENERAL NOTES.
M A
R K
D E
S C
R
IP
T
IO
N D
A
2S-201
2S-201
2S-201
2S-202
A
2S-302
B
2S-302
C
2S-302
D
2S-302
1 2 3 4 5 6
A
F
2S-302
5" CONC. SLAB w/
#3@12" OC, EW ON
VAPOR RETARDER
ON 6" CAPILLARY
WATER BARRIER
FF EL 100'-0" =
SITE EL = 849.0'
A
2S-302
A
2S-302
A
2S-302
B
2S-302
B
2S-302
C J
C J
C J
C O
N S
T J
T
C J
C J
C J
C J
C J
CJ
CJCJCJCJ
CJ
CJ
26' - 6" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 23' - 0" 18' - 6"
/4
/2
/2
/2
/4
11' - 4" 3' - 4"
1' - 8"
3' - 4" 12' - 2" 6' - 0" 8' - 0" 9' - 0" 6' - 0" 11' - 0" 4' - 0" 6' - 0" 5' - 0" 9' - 6" 6' - 0" 10' - 6" 7' - 0" 6' - 0"
2' - 0"
8' - 0"
116' - 5 3/4" 3' - 4 1/2"
2' - 1 3/4"
15' - 0" 18' - 0"
/4
/2
/2
/2
/2
/2
/2
/2
/2
/2
/4
"9
" 1
10' - 3 3/4" 6' - 4 1/2" 18' - 1 1/2"
3' - 4 1/2"
19' - 7 1/2"
3' - 4 1/2"
17' - 1 1/2"
3' - 4 1/2"
17' - 1 1/2"
3' - 4 1/2"
21' - 7 1/2"
3' - 4 1/2"
4' - 7 1/2" 3' - 4 1/2"
19' - 9 3/4"
11' - 2" 5' - 0" 8' - 8"
3' - 8" 3
CJ
CJ
CJ
2S-202
C J
E
2S-302
5' - 11 1/2"
/2
TRENCH CL
1 TYP
N 766,704.31 E 477,580.16
N 766,674.93 E 477,632.47
A
2S-303
CJ
10" 3' - 4" 1' - 10"
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-111
D D
IC
K
E Y
F L O
O R
S L A
B P
L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-1
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1/8" = 1'-0"
FLOOR SLAB PLAN
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. REFER TO 2S-001 FOR GENERAL NOTES.
SHEET NOTES
1. FLOOR DRAIN; SEE DETAIL ON SHEET
2S-301 AND PLUMBING DRAWINGS FOR
SIZE AND LOCATION
2. TRENCH DRAIN; REFER TO PLUMBING
DRAWINGS FOR PREFABRICATED
TRENCH DETAILS.
X
2S-201
2S-201
2S-201
2S-202
1 2 3 4 5 6
A
A
2S-351
26' - 6" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 23' - 0" 18' - 6"
19' - 0"
C
2S-351
8" CONC. SLAB
w/ #4@12" OC, EW T&B
TOP OF SLAB
EL = 110'-0"
2S-202
110' - 0" (TYP)
TO WALL EL =
E
2S-351
E
2S-351
2S-351
D
2S-351
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-120
D D
IC
K
E Y
E L E
V A
T E
D S
L A
B P
L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-1
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 1/8" = 1'-0"
ELEVATED SLAB PLAN
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. REFER TO 2S-001 FOR GENERAL NOTES.
M A
R K
D E
S C
R
IP
T
IO
N D
A
2S-201
2S-201
2S-201
1 2 3 4 5 6
A
A
2S-361
26' - 6" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 23' - 0" 18' - 6"
" 22K6
22K6
1' - 2" (6) EQ SPA = 25' - 4" (4) EQ SPA = 20' - 0" (6) EQ SPA = 26' - 0" (3) EQ SPA = 15' - 0" (6) EQ SPA = 26' - 0" (5) EQ SPA = 23' - 0" (4) EQ SPA = 17' - 4" 1' - 2"
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
+ 24' - 9 1/8"
W18X40
B
2S-361
C
2S-361
C
2S-361
A
2S-361
D
2S-361
E
2S-361
W X
S L O
P E
D
22K6
F
2S-361
A
2S-362
A
2S-362
INDICATES SPAN DIRECTION OF 1 1/2"
METAL ROOF DECK
LEGEND
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-130
D D
IC
K
E Y
R O
O F
F R
A M
IN
G
P L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-1
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 1/8" = 1'-0"
ROOF FRAMING PLAN
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. REFER TO 2S-001 AND 2S-002 FOR GENERAL
NOTES.
2. TOP OF STEEL ELEVATIONS ARE REFERENCED
FROM FINISHED FLOOR ELEVATION 100'-0".
3. W18X40 BEAM CONNECTIONS SHALL BE
DESIGNED FOR SERVICE LOADS AS FOLLOWS:
DL 8.64 kips LL 8.22 kips SNOW 13.00 kips WIND 10.53 kips
M A
R K
D E
S C
R
IP
T
IO
N D
A
TO SLAB
100' - 0"
JOIST BEARING
115' - 0"
A 30' - 0" 30' - 0"
(1) #6 ON
SLOPE (TYP)
(1) #6 BENT
(3) #6 @ 6" OC
(1) #6 EA SIDE
OF OPENING, TYP
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
TO SLAB
100' - 0"
JOIST BEARING
115' - 0"
123456 18' - 6" 23' - 0" 26' - 0" 15' - 0" 26' - 0" 20' - 0" 26' - 6"
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
TO SLAB = 94' - 3"
TO SLAB
100' - 0"
JOIST BEARING
115' - 0"
1 2 3 4 5 6 26' - 6" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 23' - 0" 18' - 6"
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
TO SLAB
100' - 0"
JOIST BEARING
115' - 0"
A 30' - 0" 30' - 0"
12(1) #6 ON
SLOPE (TYP)
(1) #6 BENT
(3) #6 @ 6" OC
(1) #6 EA SIDE
OF OPENING, TYP
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-201
D D
IC
K
E Y
W A
L L E
L E
V A
T I O
N S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-2
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1/8" = 1'-0"2S-110
WALL ELEVATION1
SCALE: 1/8" = 1'-0"2S-110
WALL ELEVATION3
SCALE: 1/8" = 1'-0"2S-201
WALL ELEVATION4
SCALE: 1/8" = 1'-0"2S-110
WALL ELEVATION2
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
1. ELEVATIONS SHOWN DEPICT THE 7" STRUCTURAL
(INTERIOR) WYTHE WITH THE EXTERIOR WYTHE
AND INSULATION NOT SHOWN FOR CLARITY.
SHEET NOTES
TO WALL
110' - 0"
123456 18' - 6" 23' - 0" 26' - 0" 15' - 0" 26' - 0" 20' - 0" 26' - 6"
7' - 6" 2' - 0" 6' - 0" 7' - 6" 10' - 0" 6' - 0" 10' - 0" 4' - 6" 6' - 0" 4' - 6" 10' - 6" 6' - 0" 9' - 6" 7' - 6" 6' - 0" 6' - 6"
(1) #6 EA SIDE
OF OPENING, TYP
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
TO SLAB
100' - 0"
TO WALL
110' - 0"
A
SLAB
TO SLAB = 94' - 3"
(1) #6 EA SIDE
OF OPENING, TYP
(1) #4x4'-0" LONG
DIAG BAR EACH
CORNER OF
OPENING, TYP
MINIMUM
2'-0" 3" TY
P.
M
IN
IM
U
M
#4x4'-0" LONG, EA CORNER
(1) #5 HORIZ TOP
AND BOTTOM
(1) #6 VERT
EA SIDE
NOTES:
1. CONTRACTOR SHALL COORDINATE OPENING
LOCATIONS AND DIMENSIONS WITH ARCHITECTURAL,
MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS.
2. OMIT ADDED REINFORCING AT OPENINGS OF 12" OR
LESS AND RE-ROUT SLAB AND WALL REINFORCING
ACCORDINGLY.
3. OPENINGS SHALL BE SHOWN ON SHOP DRAWINGS AND
REINFORCED ACCORDINGLY.
4. HOOK ALL INTERRUPTED BARS AT OPENING.
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-202
D D
IC
K
E Y
W A
L L E
L E
V A
T I O
N S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-2
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1/8" = 1'-0"2S-110
WALL ELEVATION1
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"2S-110
WALL ELEVATION2
1. ELEVATIONS SHOWN DEPICT THE 7" STRUCTURAL
(INTERIOR) WYTHE WITH THE EXTERIOR WYTHE
AND INSULATION NOT SHOWN FOR CLARITY.
SHEET NOTES
NOT TO SCALE
TYPICAL OPENINGS FOR CONCRETE WALLS
1/4" WIDE SAWCUT,
FILL w/ SEALER
CONC SLAB,
SEE PLAN
FF EL
SEE PLAN
SLAB CONTROL JOINT (CJ) SLAB CONSTRUCTION
JOINT (CONST JT)
VAPOR BARRIER
CAPILLARY
WATER BARRIER
CUT EVERY OTHER BAR
(KEEP BAR 2" CLR OF JOINT)
C J
CJ
C J
SLAB ON GRADE JOINTS
DISCONTINUOUS AT
INTERSECTION WITH
PERPENDICULAR JOINT
(2) #4 x 4'-0" AT
SLAB MID-DEPTH
EDGE OF SLAB
(2) #4 x 4'-0" ADDITIONAL
AT ALL RE-ENTRANT
CORNERS NOT ALIGNED
WITH CONTROL JOINT
RE-ENTRANT
CORNER
JOINT INTERSECTION DETAIL
D
/4
D /3
D S
E E
P L
A N
2"2"
KEY
CONC SLAB,
SEE PLAN
FF EL
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
D /3
D S
E E
P L
A N
FLOOR SLAB RE-ENTRANT CORNER
CONC SLAB,
SEE PLAN
WWR 6x6-W2.9xW2.9
ROUGHEN SLAB
BEFORE PLACEMENT
OF EQUIPMENT PAD
NOTE:
COORDINATE EQUIPMENT
PAD SIZE AND LOCATION
w/ MECHANICAL
FF EL
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
FF EL
SEE PLAN
FLOOR
DRAIN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
CONC SLAB,
SEE PLAN
NOTES:
1. SET UP DRAIN AS REQUIRED TO RECEIVE
FLOOR FINISH. SEE ARCH DRAWINGS.
2. SEE ARCH AND PLMB DRAWINGS FOR
SIZE AND LOCATION OF FLOOR DRAINS.
/2
FLOOR DRAIN
2' - 0" RADIUS
UNO
CL
SLOPESLOPE
(6) 3/4" DIA x6" STUDS
EQUALLY SPACED IN
RADIAL PATTERN
PIPE, REFER TO
MECHANICAL AND
ELECTRICAL FOR
PENETRATION
LOCATIONS
3/8" GALVANIZED PIPE
SLEEVE, COORDINATE
SIZE AND LOCATION
WITH MECHANICAL
CONTINUOUS WALL
REINFORCEMENT
NOT SHOWN FOR
CLARITY
INSIDE DIA. OF PIPE
SLEEVE TO BE 1/2"
LARGER THEN
OUTSIDE DIA OF PIPE
PLAN AT CORNER PLAN AT INTERSECTION
ADD CORNER BAR
TO MATCH FTG/WALL REINF
ADD CORNER BAR
TO MATCH FTG/WALL REINF
REINFORCING CONTINUOUS
THROUGH INTERSECTION
SEE SCHEDULE
LAP SPLICE
S E
E S
C H
E D
U L E
L A
P S
P L
IC
E
SEE SCHEDULE
LAP SPLICE
SEE SCHEDULE
LAP SPLICE
PLAN AT THERMOMASS
WALL CORNER
ADD CORNER BAR
TO MATCH FTG/WALL REINF
SEE SCHEDULE
LAP SPLICE
S E
E S
C H
E D
U L E
L A
P S
P L
IC
E
(1) #4 ACROSS
DOOR OPENING
FOUNDATION
WALL, SEE PLAN
1/2" EXP.
JT. MAT'L
#4 x4'-0" LONG @ 12" OC w/ 5" HOOK 1" CLEAR
1" C
LR1
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-301
D D
IC
K
E Y
T Y
P
IC
A L F
O U
N D
A T
IO
N
S E
C T
IO
N
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
NOT TO SCALE
SLAB JOINTS
NOT TO SCALE
EQUIPMENT PAD
NOT TO SCALE
FLOOR DRAIN
NOT TO SCALE
PIPE PENETRATION
NOT TO SCALE
TYPICAL FOUNDATION AND WALL DETAILS
NOT TO SCALE
ADDITIONAL SLAB REINFORCING AT DOORWAY
M A
R K
D E
S C
R
IP
T
IO
N D
A
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
ROUGHENED
CONST. JT.
#5@12" OC
(4) #4, CONT
#4@12" EW
1/2" EXP. JT. MAT'LFINISHED GRADE,
REFER TO CIVIL
3' - 0"
11" 1' - 2" 11"
4" 3" 7"
#3@16" EW
#4@12"
TO SLAB
100' - 0"
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
ROUGHENED
CONST. JT.
#5@12" OC
(4) #4, CONT
#4@12"
1/2" EXP. JT. MAT'L
3' - 0"
11" 1' - 2" 11"
CONC WALL,
BEYOND
6"
/2
/2
CONC STOOP,
REFER TO CIVIL
ADDITIONAL REINF
@ DOORWAY, SEE
TYP DETAIL 2S-301
1" EXP JT MAT'L
(1) #4, ACROSS
DOORWAY
(3) #3
(3) #4
TO SLAB
100' - 0"
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
ROUGHENED
CONST. JT.
#5@12" OC(4) #4, CONT
#4@12" EF
1/2" EXP. JT. MAT'L
3' - 0"
1' - 0" 1' - 0" 1' - 0"
#4@12" EW, EF
TO SLAB
100' - 0"
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
#5@12" OC
(4) #4, CONT
1/2" EXP. JT. MAT'L
3' - 0"
CONC WALL,
BEYOND
TO SLAB
100' - 0"
11" 1' - 2" 12' - 0" 8" 3"
ROUGHENED
CONST. JT.
#4@12" OC,
EW, T&B
#4@12" EWFINISHED GRADE,
REFER TO CIVIL
#3@16" EW
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
ROUGHENED
CONST. JT.
#4@12" EW
WATER STOP
WATER STOP
ELASTOMERIC
WATER PROOFING
MEMBRANE
ELASTOMERIC
WATERPROOFING
MEMBRANE
#4@12"
2x4 KEY
NOTE 1
FILTER
FABRIC
#4@12" EW, EF
CANT
FDN DRAIN,
REFER TO
CIVIL
FILTER FABRIC
1'-0" CRUSHED
STONE
CANT
NOTE 2
FILTER FABRIC6" CRUSHED
STONE
NOTES:
1. EXTEND WATERPROOFING MEMBRANE TO 2'-0" BEYOND PIT WALL.
TOP OF MEMBRANE SHALL TERMINATE 1'-0" BELOW FINISHED FLOOR.
2. TURN MEMBRANE AT INTERSECTING WALL AND EXTEND 2'-0".
PROVIDE CANT AT CORNER.
TO SLAB = 94' - 3"
TO SLAB
100' - 0"
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
CONC SLAB,
SEE PLAN
PREFABRICATED
TRENCH DRAIN,
REFER TO PLUMBING
COORD w/
TRENCH MFR
1' - 6"
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-302
D D
IC
K
E Y
F O
U N
D A
T
IO
N S
E C
T
IO
N S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 3/4" = 1'-0"2S-110
SECTIONA
SCALE: 3/4" = 1'-0"2S-110
SECTIONB
GRAPHIC SCALE: = 1'-0"
1' 0 2' 3'1' 4'6"
3/4"
SCALE: 3/4" = 1'-0"2S-110
SECTIONC
SCALE: 3/4" = 1'-0"2S-110
SECTIOND
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
2S-111 2S-111 2S-111 2S-111
SCALE: 3/4" = 1'-0"2S-110
SECTIONE
2S-111
SCALE: 3/4" = 1'-0"2S-111
SECTIONF
ROUGHENED
CONST. JT.
#4@12" OC,
EW, T&B
#4@12" EW, EF
CONC SLAB,
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
ROUGHENED
CONST. JT.
#4@12" EW
WATER STOPWATER STOP
ELASTOMERIC
WATER PROOFING
MEMBRANE
ELASTOMERIC
WATERPROOFING
MEMBRANE
3" 8" 14' - 0" 1' - 0" 1' - 0"
#4@12"
2x4 KEY
NOTE 1
CANT
FDN DRAIN,
REFER TO
CIVIL
NOTE 1
FILTER
FABRIC
FILTER FABRIC
CANT
1'-0" CRUSHED
STONE
FILTER FABRIC 6" CRUSHED
STONE
NOTE:
1. TURN MEMBRANE AT INTERSECTING WALL AND EXTEND 2'-0".
PROVIDE CANT AT CORNER.
TO SLAB = 94' - 3"
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-303
D D
IC
K
E Y
F O
U N
D A
T
IO
N S
E C
T
IO
N S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 3/4" = 1'-0"2S-110
SECTIONA
2S-111
GRAPHIC SCALE: = 1'-0"
1' 0 2' 3'1' 4'6"
3/4"
TO WALL
110' - 0"
A
6" 6"
STEEL COLUMN,
SEE SCHEDULE
/2
/2
#3 CLOSED
TIES
#3 CLOSED
TIES @ 12" OC
CONTINUOUS WALL
REINFORCEMENT
NOT SHOWN FOR
CLARITY
B
2S-351
TO SLAB
SEE PLAN
CONC SLAB,
SEE PLAN
#4@12" EW, EF
ROUGHENED
CONST JT
1' - 0"
A
COL
LINE
#3 CLOSED
TIES
ANCHOR RODS,
REFER TO COLUMN
SCHEDULE (4) #6 BARS
VERTICAL
1' - 0"
CONTINUOUS WALL
REINFORCEMENT
NOT SHOWN FOR
CLARITY
TO WALL
110' - 0"
COL
LINE
#4@12" EW, EF
8" CMU w/ #4
VERT @ 48" OC
DOWEL SIZE AND
SPACING TO MATCH
CMU WALL REINF
6"
A
6"
TRIANGULAR WIRE TIES 1/4" DIA
@16" OC AND CORRESPONDING
TO THE SAME LOCATION AS HORIZ
JOINT REINFORCEMENT
(1) #4 BAR AT
GROUTED CELL
STEEL COLUMN,
SEE SCHEDULE
TYP
2" CMU FACE
SHELL
CONC WALL
BELOW, TYP
TO SLAB
SEE PLAN
CONC SLAB,
SEE PLAN
#4@12" EW, EF
ROUGHENED
CONST JT
1' - 0"
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-351
D D
IC
K
E Y
F R
A M
IN
G
S E
C T
IO
N
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 1 1/2" = 1'-0"2S-120
SECTIONA
SCALE: 1 1/2" = 1'-0"2S-120
SECTIONC
GRAPHIC SCALE: = 1'-0"
1' 0 2'
1 1/2"
6" 1'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1 1/2" = 1'-0"2S-351
SECTIONB
SCALE: 1 1/2" = 1'-0"2S-120
SECTIONE
SCALE: 1 1/2" = 1'-0"2S-120
DETAIL1
SCALE: 1 1/2" = 1'-0"2S-120
SECTIOND
JOIST BEARING
115' - 0"
5 1/2"
4" 3" 7"
6"
METAL ROOF
DECK, SEE PLAN
WP
STEEL JOIST,
SEE PLAN
1/2"x5"x8" PL, w/
(2) 1/2" DIA WELDED
STUDS, MIN 5" EMBED
#4@12" EW#3@16" EW
HEIGHT OF EXTERIOR
FACE OF CONCRETE
SHALL BE COORD WITH
ROOF INSULATION
THICKNESS
A
STEEL COLUMN,
SEE SCHEDULE
STEEL JOIST,
SEE PLAN
STEEL JOIST,
SEE PLAN
STEEL BEAM,
SEE PLAN
METAL ROOF
DECK, SEE PLAN
WP
COLUMN
CAP PLATE
1/4" RIDGE
PL, CONT
METAL ROOF
DECK, SEE PLAN
STEEL JOIST,
SEE PLAN
1/2"x6"x10" PL, w/
(6) 1/2" DIA WELDED
STUDS, MIN 5" EMBED
(3) #6 @ 6" OC
#3@16" EW
STEEL BEAM,
SEE PLAN
1/4"
1/4"
3/8"x7" x6" LONG PL @ 2'-0" OC, w/ (2) 1/2" DIA
WELDED STUDS, MIN
5" EMBED
HEIGHT OF EXTERIOR
FACE OF CONCRETE
SHALL BE COORD WITH
ROOF INSULATION
THICKNESS
A
STEEL JOIST,
SEE PLAN
STEEL JOIST,
SEE PLAN
STEEL BEAM,
SEE PLAN
METAL ROOF
DECK, SEE PLAN
WP
1/4" RIDGE
PL, CONT
8" CMU w/ (1) #4
VERT @ 48" OC
SEE TYP ATTACHMENT
OF CMU TO STRUCTURE
DETAIL 2S-500
8" SLOPED
CMU BOND
BEAM
METAL ROOF
DECK, SEE PLAN
STEEL BEAM,
SEE PLAN
SEE TYP ATTACHMENT
OF CMU TO STRUCTURE
DETAIL 2S-500
8" SLOPED CMU BOND
BEAM
8" CMU w/ (1) #4
VERT @ 48" OC
6"
JOIST BEARING
115' - 0"
4" 3" 7"
6"
METAL ROOF
DECK, SEE PLAN
WP
STEEL BEAM,
SEE PLAN
1/2"x5"x8" PL, w/
(2) 1/2" DIA WELDED
STUDS, MIN 5" EMBED
#4@12" EW#3@16" EW
HEIGHT OF EXTERIOR
FACE OF CONCRETE
SHALL BE COORD WITH
ROOF INSULATION
THICKNESS
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-361
D D
IC
K
E Y
R O
O F
F R
A M
IN
G
S E
C T
IO
N
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONA
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONB
GRAPHIC SCALE: = 1'-0"
1' 0 2'
1 1/2"
6" 1'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONC
SCALE: 1 1/2" = 1'-0"2S-130
SECTIOND
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONE
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONF
METAL ROOF
DECK, SEE PLAN
#3@16" EW
3/8"x7" x6" LONG PL @ 2'-0" OC, w/ (2) 1/2" DIA
WELDED STUDS, MIN
5" EMBED
STEEL JOIST,
SEE PLAN
#4@12" EW
1' - 2" SEE PLAN
HEIGHT OF EXTERIOR
FACE OF CONCRETE
SHALL BE COORD WITH
ROOF INSULATION
THICKNESS
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-362
D D
IC
K
E Y
F R
A M
IN
G
S E
C T
IO
N
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-3
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE: 1 1/2" = 1'-0"2S-130
SECTIONA
GRAPHIC SCALE: = 1'-0"
1' 0 2'
1 1/2"
6" 1'
GROUT FILL CELLS AT VERT
REINF, MORTAR CROSS WEBS
ADJACENT TO FILLED CELLS.
LOW LIFT GROUTING SHALL
BE USED.
WHERE REINF TERMINATES AT
HIGHEST BOND BEAM, PROVIDE
STD 90° HOOK. REINF SIZE
SHALL MATCH FDN DOWELS
AND RUN CONT THROUGH
INTERMEDIATE BOND BEAM
LEVELS. PROVIDE VERT REINF
POSITIONER HARDWARE.
SPECIFIED WALL
WIDTH, SEE PLAN
FIRST COURSE
SHALL BE SET IN
FULL MORTAR BED
CONCRETE FDTN
SEE PLAN
VERT REINF SPACING,
SEE ELEVATIONS/SCHEDULE
CMU BOND BEAM @
4’ - 0” MAX, REINFORCING
CONT. ACROSS VERTICAL
CONTROL JOINTS
VERTICAL CONTROL
JOINT
WIRE LATHE OVER
NON GROUTED CELLS,
SHEET METAL OR FELT
ARE NOT PERMITTED
LAP SPLICE, SEE
SCHEDULE ON 2S-601
HORIZ. JOINT REINFORCING
"LADDER TYPE" PROVIDE
PREFABRICATED L'S AND T'S
AT WALL INTERSECTIONS.
SEE SPECS
CONCRETE
STEM WALL
8" LINTEL
UNIT w/ (2) #5
STEEL BEAM
BOTTOM FLANGE
8" BOND BEAM
CUT BLOCK
AS REQ'D
VERTICAL REINF
SEE ELEVATIONS
L6x6x1/2"x4" LONG
(LLV) @ 4'-0" OC MAX
1/4"
L6x4x1/2"x4" LONG
(LLV) @ 4'-0" OC MAX
1/4"
NOTE:
FIELD POSITION ANGLES SNUGLY
AGAINST THE WALL AND WELD IN
PLACE.
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-500
D D
IC
K
E Y
T Y
P
IC
A L M
A S
O N
R Y
D E
T A
IL
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-5
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
NOT TO SCALE
TYPICAL MASONRY CONSTRUCTION
NOT TO SCALE
TYPICAL CMU LINTEL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
TYPICAL ATTACHMENT OF CMU WALL TO STRUCTURE
DEVELOPMENT / LAP SPLICE LENGTH IN 8" MASONRY
# OF BARS
BAR SIZE
DEVELOPMENT LENGTH, in.
LAP SPLICE LENGTH, in.
DEVELOPMENT / LAP SPLICE LENGTH IN CONCRETE
BAR SIZE
DEVELOPMENT LENGTH, in.
LAP SPLICE LENGTH, in.
11 64 82
NOTE: FOR HORIZONTAL REINFORCEMENT SO PLACED THAT
MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER
BELOW THE REINFORCEMENT, MULTIPLY THE VALUES BY 1.3.
T H
R E
A D
" ASTM F1554, GR. 36
ANCHOR RODS
TYPE: 3/4" DIA.
1/4"
G R
O U
T
S E
E S
C H
E D
COL
LINE
COLUMN BEARING
ELEVATION SEE
COLUMN SCHEDULE
1/4"
2 1/2"
/2
C
C/2 C/2
B
B /2
B /2
C COLUMNL
TO SLAB TO SLAB
100' - 0" 100' - 0"
TO WALL TO WALL
110' - 0" 110' - 0"
Column Locations A-1, A-2, A-3, A-4, A-5, A-6
124' - 9 1/8"
110' - 1 3/4"
W X
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-601
D D
IC
K
E Y
S C
H E
D U
L E
S
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-6
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
COLUMN LOCATIONS
SCALE: 3/4" = 1'-0"
TYPICAL ANCHOR ROD DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL BASE PL DETAIL
GRAPHIC SCALE: = 1'-0"
1' 0 2' 3'1' 4'6"
3/4"
BASE PL DIMENSIONS
ANCHOR ROD NO.
3/4"x12"x12"
(4)
COLUMN
BEARING EL
= 100'-0"
NOTES: 1. COLUMN TOP OF STEEL ELEVATIONS ARE TO WORKING
POINT AT COLUMN CENTER LINE. IN CASES WHERE
COLUMN CAP PLATES ARE REQUIRED, TOP OF COLUMN
ELEVATION IS TO THE TOP OF CAP PLATE AT COLUMN
CENTER LINE.
2. ALL CAP PLATES ARE 1/2"
COLUMN SCHEDULE
6' - 0" 6' - 0"
-30.6
NET WIND UPLIFT PRESSURES
ZONE
ROOF FASTENER DESIGN
WIND UPLIFT PRESSURE (PSF)
-53.32
-78.73
JOIST DESIGN NET
WIND UPLIFT PRESSURE (PSF)
ZONE
-27.7
-39.1
-61.8
W
S
9 PSF
P
S F
P
S F
9' - 0"
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L
O S
IV
E
O R
D N
A N
C E
D
IS
P O
S A
L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
W F
O Y
B R
E N
N E
R
M P
O E
2S-602
D D
IC
K
E Y
W
IN
D U
P L
IF
T D
IA
G
R A
M A
N D
U N
B A
L A
N C
E D
S N
O W
L O
A D
D
IA
G R
A M
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
S
-6
RTA SUBMITTAL
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NOT TO SCALE
WIND UPLIFT DIAGRAM
GENERAL NOTES
1. REFER TO 2S-001 FOR GENERAL NOTES.
UNBALANCED SNOW LOAD DIAGRAM
2A-201
2A-201
2A-200
2A-200
2A-300
2A-300
2A-300
2A-300
DETORQUING
FINAL EXPLOSIVE
CLEAN REMOVAL
WATER JET
MACHINING
BAND SAW
10' - 4" 6' - 4" 18' - 2" 3' - 4" 19' - 8" 3' - 4" 17' - 2" 3' - 4" 17' - 2" 3' - 4" 21' - 8" 3' - 4" 4' - 8" 3' - 4" 19' - 10"
11' - 6" 3' - 0"
2' - 0"
3' - 0" 12' - 4" 6' - 0" 17' - 0" 6' - 0" 15' - 0" 6' - 0" 14' - 6" 6' - 0" 17' - 6" 6' - 0" 2' - 0"
1' - 2" 10' - 6" 14' - 4" 20' - 0" 26' - 0" 15' - 0" 26' - 0" 15' - 0" 8' - 0" 17' - 10" 1' - 2"
INERT ITEMS
STORAGE
MECHANICAL &
ELECTRICAL
X-RAY
DISASSEMBLY
TOILET
TELECOM
JAN.
STEAM OUT
STORAGE VAULT
MRFDK
155' - 0"
C O
R R
ID
O
R
2A-310
2A-310
SECURE
STORAGE
116' - 6" 3' - 4" 35' - 2"
2A-400
6' - 0"
6' - 0"
2A-300
2A-300
EQUIPMENT
ROOM
14' - 0"
BUILDING GROSS SQUARE FOOTAGE = 9,384
DOCK CANOPY (1/2) = 65
GROSS SQUARE FOOTAGE = 9,449
AUTHORIZED GROSS SQUARE FOOTAGE = 10,234
1. REFER TO STRUCTURAL DRAWINGS FOR FINISH
ELEVATIONS.
2. TYPICAL DOORS SHALL BE LOCATED 4" FROM NEAREST
WALL UNLESS OTHERWISE INDICATED.
3. SLOPE FLOORS TO DRAIN WHERE SPECIFICALLY
NOTED. REFER TO STRUCTURAL AND MECHANICAL.
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L O
S
IV
E O
R D
N A
N C
E D
IS
P
O S
A L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
F Y
P
N
J U
L Y
W
D S
-1 -D
-0
B D
U R
H A
M
M S
IE
V
E R
M P
O E
2A-110
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
K B
L A
N F
O R
D
D
IM
E N
S
IO
N P
L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
A
A -1
RTA SUBMITTAL
SCALE: 1/8" = 1'-0"
DIMENSION PLAN
04'8' 16' 24'8'
GRAPHIC SCALE: ⅛" = 1'-0"
BUILDING SQUARE FOOTAGE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
GENERAL NOTES
INDICATES DOOR NUMBER. REFER TO DOOR SCHEDULE
2A-600.
INDICATES WINDOW TYPES. REFER TO SHEET 2A-520.
INDICATES LOUVER TYPE. REFER TO SHEET 2A-530.
INDICATES WALL TYPE CONSTRUCTION. REFER TO
SHEET 2A-540 FOR WALL TYPES.
INDICATES WALLS THAT MUST BE CONTINUOUS FROM
CONCRETE FLOOR SLAB EXTENDED TO UNDERSIDE OF
DECK ABOVE AND BE SEALED.
A
B
LV
2A-201
2A-201
2A-200
2A-200
2A-300
2A-300
2A-300
2A-300
DETORQUING
FINAL EXPLOSIVE
CLEAN REMOVAL
WATER JET
MACHINING
BAND SAW
A
A
A
A
B
A
A
A
A
A
STORAGE VAULT
INERT ITEMS
STORAGE
MRFDK
DISASSEMBLY
X-RAY
MECHANICAL &
ELECTRICAL
STEAM OUT
A
A
A
A
A
B
A
B
B
C
TELECOM
JAN.
TOILET
2 2
2 2 2 2
C O
R R
ID
O
R
2A-310
2A-310
A
SECURE
STORAGE
2A-400
3 *
A
2A-300
2A-300
EQUIPMENT
ROOM
A
B
A
A 15
5 5 5
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L O
S
IV
E O
R D
N A
N C
E D
IS
P
O S
A L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
B D
U R
H A
M
M S
IE
V
E R
M P
O E
2A-111
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
K B
L A
N F
O R
D
N O
T E
P L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
A
A -1
RTA SUBMITTAL
04'8' 16' 24'8'
GRAPHIC SCALE: ⅛" = 1'-0"
LEGEND
SCALE: 1/8" = 1'-0"
NOTE PLAN
FLOOR PLAN TAG NOTES
1 PRE-FINISHED METAL DOWNSPOUT, REFER TO
ELEVATIONS.
2 CAST IRON BOOT. REFER TO CIVIL.
3 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE
BOLLARD.
4 OVERHEAD COILING DOOR: 10'-0" W X 12'-0" H.
5 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.
MOUNT AT 42" A.F.F.
6 KNOX BOX TO BE PROVIDED AND INSTALLED BY THE
CONTRACTOR. CONTRACTOR TO COORDINATE
REQUIREMENTS WITH THE FIRE DEPARTMENT.
7 FLOOR DRAIN, REFER TO PLUMBING DRAWINGS.
8 ABA COMPLIANT HI-LOW ELECTRIC WATER COOLER,
REFER TO DETAIL 1/2A-580 AND PLUMBING DRAWINGS.
9 METAL LADDER. REFER TO DETAILS 1/2A-581 AND
2/2A-581.
10 TRENCH. REFER TO STRUCTURAL DRAWINGS.
11 CANOPY ABOVE. REFER TO SHEET 2A-580.
12 PINK WATER TANK AND PIT. REFER TO MECHANICAL
AND STRUCTURAL.
13 METAL RAILING. REFER TO DETAILS 3/2A-581 AND
4/2A-581.
14 EYEWASH. REFER TO PLUMBING.
15 TWO HOLES AT CONCRETE WALL SHALL BE PROVIDED
FOR INSTRUMENT MANIPULATION DEVICES. 1 1/2"
DIAMETER HOLES SHALL BE 3'-0" A.F.F. AND 2'-0"APART
(CENTERED ON WINDOW).
M A
R K
D E
S C
R
IP
T
IO
N D
A
X-RAY
WATER JET
MACHINING
BAND SAW
DETORQUING
FINAL EXPLOSIVE
CLEAN REMOVAL
INERT ITEMS
STORAGE
TOILET
MECHANICAL &
ELECTRICAL
STORAGE VAULT
DISASSEMBLY
MRFDK
TELECOM
JAN.
STEAM OUT
C O
R R
ID
O
R
1 1
1 1 1
6 7
1 1
SECURE
STORAGE
EQUIPMENT
ROOM
CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
FURNISHINGS, FIXTURES, AND
EQUIPMENT
GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
C.F.C.I.
FF&E
G.F.G.I.
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L O
S
IV
E O
R D
N A
N C
E D
IS
P
O S
A L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
B D
U R
H A
M
M S
IE
V
E R
M P
O E
2A-112
N E
W Y
O R
K D
IS
T
R
IC
T
F
E D
E R
A L
P L
Z N
E W
Y O
R K
N
Y
K B
L A
N F
O R
D
E Q
U
IP
M E
N T
P L A
N
P
IC
A T
IN
N
Y A
R S
E N
A L N
J
A
A -1
RTA SUBMITTAL
04'8' 16' 24'8'
GRAPHIC SCALE: ⅛" = 1'-0"
SCALE: 1/8" = 1'-0"
EQUIPMENT PLAN
EQUIPMENT SCHEDULE
EQUIP.
NO. EQUIPMENT IDENTIFICATION NEW / EXISTING
APPROX.
FOOTPRINT
ROOM
NO. VOLTS AMPS PHASE PLUG MODEL NO. REMARKS/OTHER UTILITIES
1 GROUNDED WORK BENCH NEW / FF&E 96"X36" VARIOUS GRAINGER 13E337 GROUNDING
2 GROUNDED WORK BENCH NEW / FF&E 72"X30" VARIOUS GRAINGER 16Y106 GROUNDING
3 GROUNDED TOOL CABINET NEW / G.F.G.I. 60"X24" VARIOUS ULINE H 7210 GROUNDING
4 VERTICAL DRILL PRESS NEW / G.F.G.I. 36"X24" 100 120 15 1 NEMA / 5-15 PALGREN 9680209
5 HORIZONTAL LATHE NEW / G.F.G.I. 72"X36" 100 240 30 1 INTER CONNECT JET GHB 1340A COMPRESSED AIR DROP FOR BLOW GUN
6 SCALE NEW / G.F.G.I. 36"X36" 100 120 15 1 NEMA / 5-15 OPTIMA WCB1483742
7 PAINT BOOTH NEW / G.F.G.I. 60"X36" 100 120 20 1 NEMA / 5-20 MARATHON FINISHING SPB-52 VENT TO OUTSIDE / PROVIDE MAKEUP AIR / 12" VENT WITH ADAPTOR KIT. 10 FEET MAX
RUN
8 PINK WATER TANK NEW / C.F.C.I. 100 GROUNDING / REFER TO PLUMBING DRAWINGS
9 AIR COMPRESSOR NEW / C.F.C.I. 96"X48" 101 480 FUSED @ 50A 3 INTER CONNECT INGERSOLL RAND
IRN30H-TAS (OR EQUAL)
GROUNDING / CONDENSATE TO DRAIN, 120 GALLON TANK W/ PSG-7 OIL WATER
SEPARATOR
10 HIGH POWERED PUMP EXISTING / G.F.G.I. 36"X36" 116 480 100 3 INTER CONNECT MOVE FROM BUILDING 816
11 LIFT TABLE NEW / G.F.G.I. 96"X36" 102 GRAINGER 13E255
12 X-RAY READER EXISTING / G.F.G.I. 48" LONG 103 120 15 1 NEMA / 5-15 MOVE FROM BUILDING 816
13 NOT USED
14 HYDRAULIC BULLET PULLER EXISTING / G.F.G.I. 24"X24" 103 120 15 1 NEMA / 5-15 MOVE FROM BUILDING 816
15 PAN PRESS EXISTING / G.F.G.I. 24"X24" 103 120 15 1 NEMA / 5-15 MOVE FROM BUILDING 816
16 PEDESTAL VICE EXISTING / G.F.G.I. 12"X12" 103 GROUNDING / MOVE FROM BUILDING 816
17 MRFDK BARRICADED FUZE DISASSEMBLY UNIT EXISTING / G.F.G.I. 72"X36" 104 120 20 1 NEMA / 5-15 MOVE FROM BUILDING 816
18 IMPROVED MRFDK BARRICADED FUZE
DISASSEMBLY UNIT
EXISTING / G.F.G.I. 96"X36" 104 120 20 1 NEMA / 5-15 MOVE FROM BUILDING 816
19 SHELVING UNIT NEW / FF&E 72"X36" 105 & 107 GROUNDING
20 THERMAL CHAMBER NEW / G.F.G.I. 51"X65" 105 230 60 1 INTER CONNECT THERMOTRON S-27-8200
21 NOT USED
22 NOT USED
23 INDUSTRIAL TUMBLER EXISTING / G.F.G.I. 36"X24" 105 120 15 1 NEMA / 5-15 MOVE FROM BUILDING 816
24 SANDBLASTING MACHINE NEW / G.F.G.I. 36"X36" 105 120 15 1 NEMA / 5-15 ALLSOURCE 41800 COMPRESSED AIR 20 CFM, 80 PSIG
25 NOT USED
26 DETORQUING MACHINE EXISTING / G.F.G.I. 72"X36" 106 GROUNDING / MOVE FROM BUILDING 816
27 PAINT SHAKER EXISTING / G.F.G.I. 34"X40" 105 120 15 1 NEMA / 5-15 MOVE FROM BUILDING 816
28 REMOTE OPERATED BAND SAW EXISTING / G.F.G.I. 110"X80"X86"H 108 220 60 3 INTER CONNECT MOVE FROM BUILDING 816
29 WATER AND ABRASIVE JET CUTTING SYSTEM EXISTING / G.F.G.I. 72"X36" 109 120 30 1 INTER CONNECT COMPRESSED AIR 11 CFM @ 110 PSIG; 5 GPM WATER FEED / MOVE FROM BUILDING 816
30 STEAM CLEANING SYSTEM NEW / G.F.G.I. 72"X36" 110 NEW, CUSTOM SYSTEM GROUNDING
31 STEAM GENERATOR NEW / C.F.C.I. 30"X16" 116 220 50 3 INTER CONNECT SPEEDYLECTRIC STEAM
GENERATOR 15A-2 (OR
EQUAL)
32 AUTOCLAVE NEW / G.F.G.I. 36"X36" 110 GROUNDING / IPS CUSTOM SUPPLIED UNIT. BENCHTOP OR ON CART
33 LASER ENGRAVER NEW / G.F.G.I. 115"X114" 100 230 60 3 INTER CONNECT KERN LASER SYSTEMS LC50
34 VISE (HEAVY DUTY) NEW / G.F.G.I. --- VARIOUS WILTON 8100M BOLT TO TABLE
35 MILLING MACHINE NEW / G.F.G.I. 96"X54" 100 208 30 3 INTER CONNECT JET JTM-4VS AIR DROP FOR BLOW GUN
36 PUMP CHILLER EXISTING / G.F.G.I. 42"X40" 116 230 50 3 INTER CONNECT MOVE FROM BUILDING 816
37 LASER CHILLER NEW / G.F.G.I. 36"X36" 100 230 30 3 INTER CONNECT KERN LASER (SUPPLIED WITH ENGRAVER)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
LEGEND
M
2A-300
2A-300
2A-300
2A-300
2A-300
2A-300
2A-570
2A-580
2A-570
1. REFER TO SHEET 2A-570 FOR ROOF DETAILS.
2. REFER TO STRUCTURAL DRAWINGS FOR ROOF
FRAMING.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR ROOF MOUNTED EQUIPMENT.
4. ROOF SLOPES ARE NOMINAL, REFER TO STRUCTURAL
DRAWINGS FOR JOIST BEARING ELEVATIONS.
5. WHEN MULTIPLE LAYERS OF INSULATION ARE USED,
JOINTS OF SUCCESSIVE LAYERS SHALL BE OFFSET
FROM THE PREVIOUS LAYER.
6. GUTTER LENGTH SHALL NOT EXCEED 50 FEET WITHOUT
AN EXPANSION JOINT. EXPANSION JOINTS SHALL BE
INSTALLED TO COMPLY WITH THE SMACNA
ARCHITECTURAL SHEET METAL MANUAL.
SHEET ID
1 2 6 7
D R
A W
N B
Y
D E
S
IG
N B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
A N
S I D
F
A
C A
T E
G O
R Y
C O
D E
3 4 5 8 9 10
G
E
D
C
B
E X
P L O
S
IV
E O
R D
N A
N C
E D
IS
P
O S
A L
E O
D
T E
C H
N O
L O
G Y
F A
C
IL
IT
Y
M U
N
IT
IO
N
S D
IS
A
S S
E M
B L Y
F A
C
IL
IT
Y
J U
L Y
W
D S
-1 -D
-0
B D
U R
H…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.