This document provides details for an invitation for bid for a new crane barge. The U.S. Army Corps of Engineers Marine Design Center is soliciting bids to procure a crane barge to replace an existing vessel currently in operation by the Detroit District. The new barge is to be built and classed by the American Bureau of Shipping as a Maltese Cross A-1 Steel Barge for Great Lakes service. Key specifications include a length of 150 feet, beam of 50 feet, depth of 10 feet, and design waterline of 5 feet. Bidders must fabricate and deliver the barge to the St. Mary's Falls Canal in Sault Sainte Marie, Michigan, and liquidated damages are associated with the procurement. The solicitation requires bid guarantees, payment and performance bonding. Bids are due by email to Amanda.Bellnier@usace.army.mil on August 29th at 10:00am EDT.
View the file
Other files for this federal contract opportunity
Show all 50
New Crane Barge has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Est. Est. Est. Est. Est. Est. Est. Est. Est. Est.
V HP KW D.F KW D.F KW D.F KW D.F KW D.F KW D.F KW D.F KW D.F KW D.F KW D.F KW
1 DECK WINCH NO. 1 480V 7.50 5.59 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.00 0.00 0.00 0.00
2 DECK WINCH NO. 2 480V 7.50 5.59 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.20 1.12 0.00 0.00 0.00 0.00
3 DECK WINCH NO. 3 480V 7.50 5.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
4 DECK WINCH NO. 4 480V 7.50 5.59 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
5 SPUD WINCHES NO.1 480V 50.00 37.25 0.00 0.00 0.00 0.00 0.80 29.80 0.70 26.08 0.00 0.00 0.00 0.00 0.80 29.80 0.80 29.80 0.00 0.00 0.00 0.00
6 SPUD WINCHES NO.2 480V 50.00 37.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
7 SPUD WINCHES NO.3 480V 50.00 37.25 0.00 0.00 0.00 0.00 0.90 33.53 0.80 29.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
8 SPUD WINCHES NO.4 480V 50.00 37.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
9 DECK WASH DOWN PUMP 480V 25.00 18.63 0.20 3.73 0.20 3.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
10 GENERATOR NO. 1 RADIATOR FAN 480V 10.30 7.67 0.05 0.38 0.20 1.53 0.20 1.53 0.20 1.53 0.05 0.38 0.20 1.53 0.20 1.53 0.20 1.53 0.00 0.00 0.00 0.00
11 GENERATOR NO. 2 RADIATOR FAN 480V 10.30 7.67 0.05 0.38 0.20 1.53 0.20 1.53 0.20 1.53 0.05 0.38 0.20 1.53 0.20 1.53 0.20 1.53 0.00 0.00 0.00 0.00
12 STANDALONE GENERATOR RADIATOR FAN 480V 8.80 6.56 0.20 1.31 0.05 0.33 0.05 0.33 0.05 0.33 0.20 1.31 0.05 0.33 0.05 0.33 0.05 0.33 0.00 0.00 0.00 0.00
13 MACHINERY ROOM SUPPLY FAN 480V 3.00 2.24 0.50 1.12 0.40 0.89 0.50 1.12 0.40 0.89 0.50 1.12 0.40 0.89 0.50 1.12 0.40 0.89 0.00 0.00 0.00 0.00
14 MACHINERY ROOM RETURN FAN 480V 5.00 3.73 0.50 1.86 0.40 1.49 0.50 1.86 0.40 1.49 0.50 1.86 0.40 1.49 0.50 1.86 0.40 1.49 0.00 0.00 0.00 0.00
15 CRANE SERVICE LOAD 480V 54.00 40.23 0.09 3.62 0.20 8.05 0.09 3.62 0.20 8.05 0.16 6.44 0.50 20.12 0.09 3.62 0.20 8.05 0.00 0.00 0.00 0.00
16 175KVA ISOLATION TRANSFORMER NO.1 (SHORE POWER) 480V - 140.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
17 EQUIPMENT POWER PANEL - P1 - - 27.02 - 0.00 - 18.61 - 0.00 - 18.61 - 0.00 - 18.61 - 0.00 - 18.61 - 0.00 - 18.61
18 EQUIPMENT POWER PANEL - P2 - - 95.01 - 8.00 - 20.01 - 20.00 - 32.01 - 8.00 - 20.01 - 20.00 - 32.01 - 10.00 - 22.01
19 EQUIPMENT POWER PANEL - L1 - - 48.75 - 5.40 - 14.89 - 4.98 - 17.48 - 5.10 - 16.67 - 3.59 - 14.89 - 1.58 - 6.18
20 GEN.LIGHTING/RECEP. PANEL - L2 - - 21.04 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69 - 9.69
21 GEN.LIGHTING/RECEP. PANEL - L3 - - 37.94 - 13.82 - 13.34 - 13.82 - 13.34 - 13.82 - 13.34 - 13.82 - 13.34 - 13.82 - 13.34
22 HVAC POWER PANEL - L4 - - 7.13 - 4.31 - 3.57 - 5.20 - 2.67 - 4.31 - 3.57 - 5.20 - 3.49 - 5.20 - 3.49
23 DECK LOAD PANEL - L5 - - 64.44 - 4.68 - 4.68 - 2.92 - 2.92 - 4.68 - 9.36 - 3.07 - 3.07 - 3.07 - 3.07
TOTAL 699.40 60.53 104.58 132.16 168.65 59.32 119.38 97.39 140.95 43.35 76.38
24 HOT WATER UNIT HEATER NO.1 - MACHINERY ROOM 480V 4.03 3.00 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80
25 HOT WATER UNIT HEATER NO.2 - MACHINERY ROOM 480V 4.03 3.00 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50
26 HOT WATER UNIT HEATER NO.3 - MACHINERY ROOM 480V 4.03 3.00 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80 0.00 0.00 0.60 1.80
27 HOT WATER UNIT HEATER NO.4 - MACHINERY ROOM 480V 4.03 3.00 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50
28 HOT WATER UNIT HEATER - GENERATOR ROOM 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
29 HOT WATER UNIT HEATER - BOILER ROOM 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
30 HOT WATER UNIT HEATER - FWD WINCH ROOM 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
31 HOT WATER UNIT HEATER - AFT WINCH ROOM 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
32 HOT WATER UNIT HEATER - STORAGE SPACE (FR.9-FR.17) 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
TOTAL 27.02 0.00 18.61 0.00 18.61 0.00 18.61 0.00 18.61 0.00 18.61
33 SPACE HEATER - GALLEY/MESS 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
34 SPACE HEATER - DAY ROOM 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
35 SPACE HEATER - 6 CREW 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
36 SPACE HEATER - DECK OPERATOR CONTROL HOUSE 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
37 SPACE HEATER - CONTROL HOUSE/OFFICE 480V 4.03 3.00 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40 0.00 0.00 0.80 2.40
38 480V, 3P, OUTLET NO.1 (Appleton ACP603BC) 480V 53.69 40.00 0.20 8.00 0.20 8.00 0.50 20.00 0.50 20.00 0.20 8.00 0.20 8.00 0.50 20.00 0.50 20.00 0.25 10.00 0.25 10.00
39 480V, 3P, OUTLET NO.2 (Appleton ACP603BC) 480V 53.69 40.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TOTAL 95.01 8.00 20.01 20.00 32.01 8.00 20.01 20.00 32.01 10.00 22.01
CONNECTED LOAD
LOAD DESCRIPTION SUMMER SUMMER SUMMERWINTER WINTER
EQUIPMENT POWER PANEL - P2 (480VAC, 3PH, 3W)
WINTER
MAIN SWITCHBOARD (480VAC, 3PH, 3W)
USACE 3265 150FT CELRE CRANE BARGE AC LOAD ANALYSIS
EQUIPMENT POWER PANEL - P1 (480VAC, 3PH, 3W)
OPERATION CONDITION 1 OPERATION CONDITION 2
SUMMER WINTER
OPERATION CONDITION 5OPERATION CONDITION 3
Operating Condition 2: Lifting two spuds simultaneously, barge service loads and crane general service loads except crane diesel heater loads.
Operating Condition 3: Crane general service, crane heating and barge service loads.
Operating Condition 5: Shore Power Connection loads.
Operating Condition 4: Lifting one spud, barge service loads and crane general service loads except crane diesel heater loads.
ITEM NO.
OPERATION CONDITION 4
SUMMER WINTER
LEGEND:
Operating Condition 1: Barge service loads and crane general service loads except crane diesel heater loads.
TAI-1240 USACE_150'x50'x10' CELRE CRANE BARGE MDC Project: 3265, Hull No: 866
07/05/2021 Rev 1
CONNECTED LOAD
LOAD DESCRIPTION SUMMER SUMMER SUMMERWINTER WINTERWINTER
USACE 3265 150FT CELRE CRANE BARGE AC LOAD ANALYSIS
OPERATION CONDITION 1 OPERATION CONDITION 2
SUMMER WINTER
OPERATION CONDITION 5OPERATION CONDITION 3
ITEM NO.
OPERATION CONDITION 4
SUMMER WINTER
40 GENERATOR NO.1 BATTERY CHARGER 120V - 0.50 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30
41 GENERATOR NO.2 BATTERY CHARGER 120V - 0.50 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30 0.60 0.30
42 24VDC BATTERY CHARGER NO.1 120V - 0.75 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08
43 24VDC BATTERY CHARGER NO.2 120V - 0.75 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10 0.08
44 STANDALONE GENERATOR BATTERY CHARGER 120V - 0.50 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15
45 GENERAL ALARM BATTERY CHARGER 120V - 0.25 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08 0.30 0.08
46 CRANE HEATER 120V - 1.00 0.00 0.00 0.90 0.90 0.00 0.00 0.90 0.90 0.00 0.00 0.90 0.90 0.00 0.00 0.90 0.90 0.00 0.00 0.20 0.20
47 GENSETS NO.1 BLOCK HEATER 120V - 1.50 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.20 0.30
48 GENSETS NO.2 BLOCK HEATER 120V - 1.50 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.50 0.75 0.00 0.00 0.20 0.30
49 SWITCHBOARD SPACE HEATERS 120V - 1.50 0.20 0.30 0.90 1.35 0.00 0.00 0.90 1.35 0.00 0.00 0.90 1.35 0.00 0.00 0.90 1.35 0.00 0.00 0.20 0.30
50 STANDALONE GENERATOR BLOCK HEATER 120V - 1.50 0.00 0.00 0.00 0.00 0.00 0.00 0.20 0.30 0.00 0.00 0.90 1.35 0.00 0.00 0.20 0.30 0.00 0.00 0.20 0.30
51 WINCH ROOM NO. 1 HEATER 120V - 1.00 0.00 0.00 0.20 0.20 0.00 0.00 0.80 0.80 0.00 0.00 0.20 0.20 0.00 0.00 0.50 0.50 0.00 0.00 0.20 0.20
52 WINCH ROOM NO. 2 HEATER 120V - 1.00 0.00 0.00 0.20 0.20 0.00 0.00 0.80 0.80 0.00 0.00 0.20 0.20 0.00 0.00 0.50 0.50 0.00 0.00 0.20 0.20
53 WINCH ROOM NO. 3 HEATER 120V - 1.00 0.00 0.00 0.20 0.20 0.00 0.00 0.80 0.80 0.00 0.00 0.20 0.20 0.00 0.00 0.50 0.50 0.00 0.00 0.20 0.20
54 WINCH ROOM NO. 4 HEATER 120V - 1.00 0.00 0.00 0.20 0.20 0.00 0.00 0.80 0.80 0.00 0.00 0.20 0.20 0.00 0.00 0.50 0.50 0.00 0.00 0.20 0.20
55 FUEL OIL BOILER NO.1 208V - 5.96 0.10 0.60 0.35 2.09 0.10 0.60 0.35 2.09 0.10 0.60 0.35 2.09 0.10 0.60 0.35 2.09 0.00 0.00 0.00 0.00
56 FUEL OIL BOILER NO.2 208V - 5.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
57 PRESSURE SET PUMP 120V - 0.56 0.30 0.17 0.30 0.17 0.10 0.06 0.10 0.06 0.30 0.17 0.30 0.17 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
58 SANITARY/BLACK WATER TRANSFER PUMP 208V 5.00 3.73 0.20 0.75 0.10 0.37 0.20 0.75 0.10 0.37 0.20 0.75 0.20 0.75 0.20 0.75 0.10 0.37 0.00 0.00 0.00 0.00
59 LUBE OIL TRANSFER PUMP 120V 0.75 0.56 0.20 0.11 0.10 0.06 0.20 0.11 0.10 0.06 0.20 0.11 0.20 0.11 0.20 0.11 0.10 0.06 0.00 0.00 0.00 0.00
60 FUEL OIL TRANSFER PUMP 120V 0.75 0.56 0.20 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.20 0.11 0.00 0.00 0.00 0.00
61 BILGE PUMP (POTABLE) 120V 1.00 0.75 0.20 0.15 0.20 0.15 0.20 0.15 0.20 0.15 0.20 0.15 0.20 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
62 BALLAST PUMP (POTABLE) 208V 8.00 5.96 0.20 1.19 0.20 1.19 0.20 1.19 0.20 1.19 0.20 1.19 0.20 1.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
63 HEATING WATER CIRCULATING PUMP NO.1 208V 3.00 2.24 0.20 0.45 0.50 1.12 0.20 0.45 0.50 1.12 0.20 0.45 0.50 1.12 0.20 0.45 0.50 1.12 0.00 0.00 0.00 0.00
64 HEATING WATER CIRCULATING PUMP NO.2 208V 3.00 2.24 0.00 0.00 0.50 1.12 0.00 0.00 0.50 1.12 0.00 0.00 0.50 1.12 0.00 0.00 0.50 1.12 0.00 0.00 0.00 0.00
65 WATER HEATER 120V 6.00 0.10 0.60 0.50 3.00 0.10 0.60 0.50 3.00 0.10 0.60 0.50 3.00 0.10 0.60 0.50 3.00 0.10 0.60 0.50 3.00
TOTAL 48.75 5.40 14.89 4.98 17.48 5.10 16.67 3.59 14.89 1.58 6.18
66 DECK OPERATOR CONTROL HOUSE LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
67 CONTROL HOUSE/OFFICE LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
68 DECK OPERATOR CONTROL HOUSE RECEPTACLES NO.1 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
69 DECK OPERATOR CONTROL HOUSE RECEPTACLES NO.2 120V - 1.80 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36
70 CONTROL HOUSE/OFFICE RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
71 MAIN DECK AFT PORT FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
72 MAIN DECK AFT PORT FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
73 MAIN DECK AFT STBD FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
74 MAIN DECK AFT STBD FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
75 AFT WINCH ROOM LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
76 GENERATOR ROOM LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
77 MACHINERY ROOM LIGHTING NO.1 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
78 MACHINERY ROOM LIGHTING NO.2 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
79 BOILER ROOM LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
80 STORAGE (P) LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
81 STORAGE (C) LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
82 AFT WINCH ROOM RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
83 GENERATOR ROOM RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
84 MACHINERY ROOM RECEPTACLES NO.1 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
85 MACHINERY ROOM RECEPTACLES NO.2 120V - 1.80 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54
86 BOILER ROOM RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
87 STORAGE (P) RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
88 STORAGE (S) RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
89 STORAGE (C) RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
90 FWD WINCH ROOM LIGHTING 120V - 0.10 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05 0.50 0.05
TOTAL 21.04 9.69 9.69 9.69 9.69 9.69 9.69 9.69 9.69 9.69 9.69
EQUIPMENT POWER PANEL - L1 (208/120VAC, 3PH, 4W)
GEN. LIGHTING/RECEP. PANEL - L2 (208/120VAC, 3PH, 4W)
TAI-1240 USACE_150'x50'x10' CELRE CRANE BARGE MDC Project: 3265, Hull No: 866
07/05/2021
CONNECTED LOAD
LOAD DESCRIPTION SUMMER SUMMER SUMMERWINTER WINTERWINTER
USACE 3265 150FT CELRE CRANE BARGE AC LOAD ANALYSIS
OPERATION CONDITION 1 OPERATION CONDITION 2
SUMMER WINTER
OPERATION CONDITION 5OPERATION CONDITION 3
ITEM NO.
OPERATION CONDITION 4
SUMMER WINTER
91 GALLEY/MESS LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
92 GALLEY REFRIGERATOR RECEPTACLE 120V - 2.40 0.30 0.72 0.10 0.24 0.30 0.72 0.10 0.24 0.30 0.72 0.10 0.24 0.30 0.72 0.10 0.24 0.30 0.72 0.10 0.24
93 GALLEY MICROWAVE RECEPTACLE 120V - 2.40 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72
94 GALLEY COFFEE MAKERS RECEPTACLE 120V - 2.40 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72
95 GALLEY COOKING RANGE RECEPTACLE 120V - 2.40 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72 0.30 0.72
96 GALLEY COUNTERTOP RECEPTACLE#1 120V - 3.60 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08
97 GALLEY RECEPTACLES 120V - 1.80 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54
98 WORK SHOP/STORAGE LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
99 DAY ROOM LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
100 6 CREW LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
101 HEAD PORT LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
102 HEAD STBD LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
103 FWD WINCH ROOM LIGHTING 120V - 0.10 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06 0.60 0.06
104 WORK SHOP/STORAGE RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
105 DAY ROOM RECEPTACLES NO.1 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
106 DAY ROOM RECEPTACLES NO.2 120V - 1.80 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54
107 CREW RECEPTACLES NO. 1 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
108 CREW RECEPTACLES NO. 2 120V - 1.80 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54 0.30 0.54
109 HEAD PORT RECEPTACLE 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
110 HEAD STBD RECEPTACLE 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
111 FWD WINCH ROOM RECEPTACLES 120V - 1.80 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90 0.50 0.90
112 MAIN DECK EXTERIOR LIGHTING (PORT) 120V - 0.10 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04
113 MAIN DECK EXTERIOR LIGHTING (STBD) 120V - 0.10 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04
114 MAIN DECK FWD PORT FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
115 MAIN DECK FWD STBD FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
116 MAIN DECK FWD PORT FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
117 MAIN DECK FWD STBD FLOOD LIGHT 120V - 0.06 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02 0.40 0.02
118 MAIN DECK EXTERIOR LIGHTING (PORT CENTER) 120V - 0.10 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04
119 GALLEY COUNTERTOP RECEPTACLE#2 120V - 3.60 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08
120 GALLEY COUNTERTOP RECEPTACLE#3 120V - 3.60 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08 0.30 1.08
121 MAIN DECK EXTERIOR LIGHTING (STBD CENTER) 120V - 0.10 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04 0.40 0.04
TOTAL 37.94 13.82 13.34 13.82 13.34 13.82 13.34 13.82 13.34 13.82 13.34
122 FWD WINCH ROOM EXHAUST FAN 208V 0.75 0.56 0.60 0.34 0.50 0.28 0.90 0.50 0.50 0.28 0.60 0.34 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
123 AIR HANDLER UNIT 208V 2.50 1.86 0.50 0.93 0.50 0.93 0.50 0.93 0.20 0.37 0.50 0.93 0.50 0.93 0.50 0.93 0.20 0.37 0.50 0.93 0.20 0.37
124 WORKSHOP/STORAGE SUPPLY FAN 208V 0.75 0.56 0.60 0.34 0.50 0.28 0.90 0.50 0.50 0.28 0.60 0.34 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
125 WORKSHOP/STORAGE EXHAUST FAN 208V 0.75 0.56 0.60 0.34 0.50 0.28 0.90 0.50 0.50 0.28 0.60 0.34 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
126 BOILER ROOM SUPPLY FAN 208V 1.00 0.75 0.60 0.45 0.50 0.37 0.90 0.67 0.50 0.37 0.60 0.45 0.50 0.37 0.90 0.67 0.70 0.52 0.90 0.67 0.70 0.52
127 GENERATOR ROOM SUPPLY FAN 208V 0.75 0.56 0.90 0.50 0.50 0.28 0.90 0.50 0.50 0.28 0.90 0.50 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
128 GENERATOR ROOM EXHAUST FAN 208V 0.75 0.56 0.90 0.50 0.50 0.28 0.90 0.50 0.50 0.28 0.90 0.50 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
129 AFT WINCH ROOM EXHAUST FAN 208V 0.75 0.56 0.60 0.34 0.50 0.28 0.90 0.50 0.50 0.28 0.60 0.34 0.50 0.28 0.90 0.50 0.70 0.39 0.90 0.50 0.70 0.39
130 HEAD EXHAUST FAN (BELOW DECK) 120V 0.03 0.02 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01
131 HEAD EXHAUST FAN (DECK) 120V 0.03 0.02 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01 0.50 0.01 0.60 0.01
132 GALLEY EXHAUST FAN 120V 1.27 0.95 0.50 0.47 0.50 0.47 0.50 0.47 0.20 0.19 0.50 0.47 0.50 0.47 0.50 0.47 0.20 0.19 0.50 0.47 0.20 0.19
133 CONDENSER UNIT 120V 0.25 0.19 0.50 0.09 0.50 0.09 0.50 0.09 0.20 0.04 0.50 0.09 0.50 0.09 0.50 0.09 0.20 0.04 0.50 0.09 0.20 0.04
TOTAL 7.13 4.31 3.57 5.20 2.67 4.31 3.57 5.20 3.49 5.20 3.49
134 WELDING RECEPTACLES - STERN 60 AMPS 120/240V - 11.52 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15 0.20 2.30 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15
135 DECK RECEPTACLE - 60 AMPS #1 (GFCI) 120/240V - 11.50 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15 0.20 2.30 0.10 1.15 0.10 1.15 0.10 1.15 0.10 1.15
136 DECK RECEPTACLE - 60 AMPS #2 (GFCI) 120/240V - 11.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
137 DECK RECEPTACLE - 60 AMPS #3 (GFCI) 120/240V - 11.50 0.10 1.15 0.10 1.15 0.00 0.00 0.00 0.00 0.10 1.15 0.20 2.30 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
138 DECK RECEPTACLE - 32 AMPS #1 (GFCI) 120/240V - 6.14 0.10 0.61 0.10 0.61 0.10 0.61 0.10 0.61 0.10 0.61 0.20 1.23 0.13 0.77 0.13 0.77 0.13 0.77 0.13 0.77
139 DECK RECEPTACLE - 32 AMPS #2 (GFCI) 120/240V - 6.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
140 DECK RECEPTACLE - 32 AMPS #3 (GFCI) 120/240V - 6.14 0.10 0.61 0.10 0.61 0.00 0.00 0.00 0.00 0.10 0.61 0.20 1.23 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TOTAL 64.44 4.68 4.68 2.92 2.92 4.68 9.36 3.07 3.07 3.07 3.07
DECK LOAD PANEL - L5 (208/120VAC, 3PH, 4W)
HVAC POWER PANEL - L4 (208/120VAC, 3PH, 4W)
GEN. LIGHTING/RECEP. PANEL - L3 (208/120VAC, 3PH, 4W)
TAI-1240 USACE_150'x50'x10' CELRE CRANE BARGE MDC Project: 3265, Hull No: 866
07/05/2021
CONNECTED LOAD
LOAD DESCRIPTION SUMMER SUMMER SUMMERWINTER WINTERWINTER
USACE 3265 150FT CELRE CRANE BARGE AC LOAD ANALYSIS
OPERATION CONDITION 1 OPERATION CONDITION 2
SUMMER WINTER
OPERATION CONDITION 5OPERATION CONDITION 3
ITEM NO.
OPERATION CONDITION 4
SUMMER WINTER
141 Design & Service Margin (Exc. Spuds) 55.04 6.05 10.46 6.88 11.28 5.93 11.94 6.76 11.12 4.34 7.64
142 Total Load (Inc. Margin) 754.44 66.58 115.03 139.05 179.93 65.25 131.32 104.15 152.07 47.69 84.02
143 100 0 0.00 1 100.00 1 100.00 1 100.00 0 0.00 1 100.00 1 100.00 1 100.00 0 0.00 0 0.00
144 100 0 0.00 1 100.00 1 100.00 1 100.00 0 0.00 1 100.00 1 100.00 1 100.00 0 0.00 0 0.00
145 75 1 75.00 0 0.00 0 0.00 0 0.00 1 75.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00
146 133 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 1 133.00 1 133.00
% 88.77% 57.52% 69.52% 89.97% 87.00% 65.66% 52.08% 76.03% 35.85% 63.17%
- 1 2 2 2 1 2 2 2 1 1
WINTER
Item No.
SUMMER WINTERWINTER
OPERATING CONDITION - 04
eKW
SUMMER WINTER WINTERSUMMER
OPERATING CONDITION - 03
SUMMER
SUMMARY
MARGIN SECTION
ELECTRIC LOAD PER GENSET
NO OF GENSET ON LOAD
10.0%
Power Source
GENSET # 1
GENSET # 2
Standalone Generator
Shore Power (Thomas & Betts DS2404MP000)
OPERATING CONDITION - 01 OPERATING CONDITION - 02 OPERATING CONDITION - 04
SUMMER
TAI-1240 USACE_150'x50'x10' CELRE CRANE BARGE MDC Project: 3265, Hull No: 866