This document contains calculations for selecting resilient mounts for machinery and winches on a new crane barge procurement. The U.S. Army Corps of Engineers Marine Design Center is soliciting bids for the fabrication and delivery of a 150-foot-long by 50-foot-wide steel crane barge to operate on the Great Lakes out of Sault Sainte Marie, Michigan. The barge must be ABS-classed and meet intact stability standards. It will have a design waterline of 5 feet and 4 inches of camber. Liquidated damages and payment and performance bonds are required. Bids are due by August 29th at 10:00am EDT to the specified USACE contact. The calculations provided determine the disturbing frequency, natural frequency, required spring stiffness, and recommended resilient mounts for two air compressors that will be installed on the barge based on their specifications and load ratings.
View the file
Other files for this federal contract opportunity
Show all 50
New Crane Barge has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Proj No.
Date:
10/5/2021
AIR COMPRESSOR PARTICULARS:
1 Make BOSS Model FT4 210 DUS 210 CFM Final Tier 4 Diesel Air Compressor Weight (Static) 2620 lbs Max. load acting on a mount (dynamic) 1915.61 lbs
RPM 2400
Disturbing frequency of system (fd) 40.00 Hz Maximum transmissibility allowed (T) 10 %
Ratio of disturbing frequency to natural frequency,(fd/fn) 3.32 in
Spring stiffness required to obtain the desired natural frequency, = 28441.03 lbs/in
( 4977.18 ) kN/m
2 Make SAYLOR BEALL Model UL-758-14
21.2 CFM Final Tier 4 Diesel Air Compressor Weight (static) 670 lbs Max. load acting on a mount (dynamic) 446.51 lbs
RPM 900
Disturbing frequency of system (fd) 15.00 Hz
(fn) 4.52 Hz
Static deflection (ds) 0.4790 in Spring stiffness (K) 932.25 lbs/in
( 163.14 ) kN/m Note:
UNIT CONVERSION: Prep By BS Chk By CT App By
PROJECT TITLE:
TAI-1240 CRANE BARGE
SUBJECT:
RESILIENT MOUNT SELECTION AND TRANSMISSIBILITY CHECK
When the vibration frequency is not known, calculations of the disturbing frequency (Hz) can be done based on the operating speed (RPM).
1 lbs/inch = 0.175 kN/m
Natural frequency
Required static deflection (in) is calculated based on the natural frequency (Hz) of system which needs for 90% isolation or 10% transmissibility, (ds)
For selecting resilient mount, it is advisable to select a mount with a maximum load rating equal or greater than the calculated load per mount and a spring rate (K) less than the calculated spring rate.
= 0.0674
12.06 HzNatural frequency, considering the system needs 90% isolation, (fn)
Selected Standard Items
1 AIR COMPRESSOR, BOSS MAKE
REF: Prep By BS Chk By CT Apv By
2 AIR COMPRESSOR, SAYLOR BEALL MAKE
REF: Prep By BS Chk By CT Apv By