01 35 29.13 Contaminated Site

View the file

Other files

File Type Posted
SF1442_W911S8-17-R-0001_0002.pdf PDF
4. Technical Exbhibit C Statement of Work 19 Dec 2016.pdf PDF
JBLM Paving W911S8-17-R-0001 Contractor QUESTIONS 22 Dec16.pdf PDF
Pre-Proposal Conference Contractor Attendees.pdf PDF
33 71 02UNDERGROUND ELECTRICAL DISTRIBUTION.pdf PDF
SF30 W911S8-17-R-0001 0002.pdf PDF
Attachment 1- Sample Project 19 December 2016.pdf PDF
32 12 21-BITUMINOUS ROAD-MIX SURFACE COURSE.pdf PDF
01_45_00_10_Quality_Control_19_Dec.pdf PDF
33 71 02 JBLM DESIGN STANDARDS-UNDERGROUND ELECTRICAL DISTRIBUTION.pdf PDF
Site Visit Briefing W911S8-17-R-0001 JBLM Paving -29 Nov 2016.pdf PDF
SF30 W911S8-17-R-0001 0001.pdf PDF
W911S8-17-R-0001_Amendment_0001.pdf PDF
01 57 19-TEMPORARY ENVIRONMENTAL CONTROLS.pdf PDF
01 42 00-SOURCES FOR REFERENCE PUBLICATIONS.pdf PDF
13. Attachment 5 - Past Performance Questionaire.docx DOCX document
32_84_24_(Irrigation_Sprinkles).pdf PDF
26_56_13.00_40_Lighting_Poles_and_Standards.pdf PDF
14. Attachment 6 Insurance Certificate of Compliance.docx DOCX document
01 78 23-OPERATION AND MAINTENANCE DATA.pdf PDF
32_17_24.00_10_(Pavement_Markings).pdf PDF
1. RFP W911S8-17-R-0001 Paving IDC.pdf PDF
01 50 00-TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS.pdf PDF
01 32 01 00 10 Project Schedule.pdf PDF
7. TE F General Decision Number WA160001 Dtd 19 Aug 16.pdf PDF
31_11_00_Clearing_ _Grubbing.pdf PDF
5. TE D-Table of Contents.pdf PDF
3. TE B Proposal Item Descriptions(09-27-16).pdf PDF
10. Attachment 2-Experience Document.docx DOCX document
6. TE E Standards Plans Drawings 25Aug16.pdf PDF
31_23_00.00_20_Excavation_ _Fill.pdf PDF
32_11_24_CSBC_for_Flexible_Pavement.pdf PDF
32_31_26_(Wire_Fence_ _Gate).pdf PDF
32_31_13.53_(High_Security_Fence).pdf PDF
26_56_19.00_40_Roadway_Lighting.pdf PDF
32_93_00_(Exterior_Plants).pdf PDF
31_00_00_Earthwork.pdf PDF
2. TE A ELIN Proposal Schedule 11 Oct 16.xlsx XLSX spreadsheet
33_11_00-WATER_DISTRIBUTION.pdf PDF
01 45 00 10 Quality Control.pdf PDF
01 30 00 Administrative Requirements.pdf PDF
33_30_00-SANITARY_SEWERS.pdf PDF
01 78 00- CLOSEOUT SUBMITTALS.pdf PDF
32_01_13_BITUMINOUS_SEAL_AND_FOG_COATS.pdf PDF
16. Attachment 8-JBLM Installation Access Information.docx DOCX document
32_92_19_(Seeding).pdf PDF
32_12_10_(Tack_Coat).pdf PDF
12. Attachment 4 - Relevant Contract Reference Sheet.docx DOCX document
00 10 01 - Supplementary Requirements.pdf PDF
32_12_15.13_HMA_for_Airfields.pdf PDF
Show 40 more

Latest 50 of 74 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 01 35 29.13 Page 1

SECTION 01 35 29.13

HEALTH, SAFETY, AND EMERGENCY RESPONSE PROCEDURES

FOR CONTAMINATED SITES

11/15

PART 1 GENERAL

1.1 REFERENCES

1.2 DESCRIPTION OF WORK

1.3 SUBMITTALS

1.4 REGULATORY REQUIREMENTS

1.5 PRECONSTRUCTION SAFETY CONFERENCE

1.6 ACCIDENT PREVENTION PLAN/SITE SAFETY AND HEALTH PLAN

(APP/SSHP)

1.7 SITE DESCRIPTION AND CONTAMINATION CHARACTERIZATION

1.8 TASK SPECIFIC HAZARDS, INITIAL PPE, HAZWOPER MEDICAL

1.9 STAFF ORGANIZATION, QUALIFICATION AND RESPONSIBILITIES

1.10 TRAINING

1.11 PERSONAL PROTECTIVE EQUIPMENT

1.12 MEDICAL SURVEILLANCE PROGRAM

1.13 EXPOSURE MONITORING/AIR SAMPLING PROGRAM

1.14 HEAT STRESS MONITORING AND MANAGEMENT

1.15 SPILL AND DISCHARGE CONTROL

1.16 MATERIALS TRANSFER SAFETY

1.17 DRUM AND CONTAINER HANDLING

1.18 CONFINED SPACE ENTRY PROCEDURES

1.19 HOT WORK

1.20 IGNITION SOURCES

1.21 FIRE PROTECTION AND PREVENTION

1.22 ELECTRICAL SAFETY

1.23 EXCAVATION AND TRENCH SAFETY

1.24 GUARDING OF MACHINERY AND EQUIPMENT

1.25 LOCKOUT/TAGOUT

1.26 FALL PROTECTION

1.27 HAZARD COMMUNICATION

1.28 ILLUMINATION

1.29 SANITATION

1.30 ENGINEERING CONTROLS

1.31 PROCESS SAFETY MANAGEMENT

1.32 SIGNS AND LABELS

1.33 WASTE DISPOSAL

SECTION 01 35 29.13 Page 2

1.34 TANK PURGING FOR PERMIT-REQUIRED CONFINED SPACE

ENTRIES

1.35 TANK INERTING (NO ENTRY)

1.36 TANK ATMOSPHERE TESTING

1.37 TANK LIFTING

1.38 TANK DEMOLITION

1.39 TANK CLEANING

1.40 SITE CONTROL MEASURES

1.41 PERSONAL HYGIENE AND DECONTAMINATION

1.42 EMERGENCY EQUIPMENT AND FIRST AID REQUIREMENTS

1.43 EMERGENCY RESPONSE AND CONTINGENCY PROCEDURES

1.44 CERTIFICATE OF WORKER/VISITOR ACKNOWLEDGEMENT

1.45 INSPECTIONS

1.46 SAFETY AND HEALTH PHASE-OUT REPORT

PART 2 PRODUCTS (NOT USED)

PART 3 EXECUTION (NOT USED)

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN PETROLEUM INSTITUTE (API)

API RP 2219 (2005; R2012) Safe Operation of Vacuum Trucks in Petroleum Service

INTERNATIONAL SAFETY EQUIPMENT ASSOCIATION (ISEA)

ANSI/ISEA Z358.1 (2014) American National Standard for Emergency Eyewash and Shower Equipment

NATIONAL INSTITUTE FOR OCCUPATIONAL SAFETY AND HEALTH (NIOSH)

NIOSH 85-115 (1985) Occupational Safety and Health Guidance Manual for

Hazardous Waste Site Activities

U.S. ARMY CORPS OF ENGINEERS (USACE)

SECTION 01 35 29.13 Page 3

EM 385-1-1 (2014) Safety and Health Requirements Manual

ER 385-1-95 2007; Errata 2007) Safety -- Safety and Health Requirements for Munitions and Explosives of Concern (MEC) Operations EM 385-1-97 (2013) Explosives - Safety and Health Requirements Manual

ER 385-1-92 (2007) Safety and Occupational Health Requirements for

Hazardous, Toxic, and Radioactive Waste (HTRW) Activities

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

10 CFR 20 Standards for Protection Against Radiation

29 CFR 1904 Recording and Reporting Occupational Injuries and Illnesses

29 CFR 1910 Occupational Safety and Health Standards

29 CFR 1910.120 Hazardous Waste Operations and Emergency Response

29 CFR 1926 Safety and Health Regulations for Construction

29 CFR 1926.65 Hazardous Waste Operations and Emergency Response

49 CFR 171 General Information, Regulations, and Definitions

49 CFR 172 Hazardous Materials Table, Special Provisions, Hazardous

Materials Communications, Emergency Response Information, and Training Requirements

1.2 DESCRIPTION OF WORK

This section requires Contractors to implement practices and procedures for working safely and in compliance with OSHA and USACE regulation while performing cleanup activities on uncontrolled hazardous waste sites.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Work Zones; G

SECTION 01 35 29.13 Page 4

Drawings including initial work zone boundaries: Exclusion Zone (EZ), including restricted and regulated areas; Contamination Reduction Zone (CRZ); and Support Zone

(SZ).

Decontamination Facilities; G

Drawings showing the layout of the personnel and equipment decontamination areas or facilities.

SD-03 Product Data

Exposure Monitoring/Air Sampling Program

Personnel exposure monitoring/sampling results.

Site Control Log

Record of each entry and exit into the site, as specified.

Employee Certificates

A certificate for each worker performing cleanup operations with potential for contaminant-related occupational exposure signed by the safety and health manager and the occupational physician indicating the workers meet the training and medical surveillance requirements of this contract.

1.4 REGULATORY REQUIREMENTS

Comply with EM 385-1-1, OSHA requirements in 29 CFR 1910 and 29 CFR 1926 with work performed under this contract, especially OSHA's Standards 29 CFR 1926.65 and 29 CFR 1910.120 and state specific OSHA requirements where applicable. Submit to the Contracting Officer for resolution matters of interpretation of standards before starting work. The most stringent requirements apply where the requirements of this specification, applicable laws, criteria, ordinances, regulations, and referenced documents vary.

1.5 PRECONSTRUCTION SAFETY CONFERENCE

Set up a preconstruction safety conference prior to the start of site activities and after submission of the Contractor's APP/SSHP. The objective of the meeting will be to discuss health and safety concerns related to the impending work, discuss project health and safety organization and expectations, review and answer comments and concerns regarding the APP/SSHP or other health and safety concerns the Contractor may have. Ensure that those individuals responsible for health and safety at the project level are available and attend this meeting.

1.6 ACCIDENT PREVENTION PLAN/SITE SAFETY AND HEALTH PLAN (APP/SSHP)

Develop and implement a Site Safety and Health Plan and attach to the Accident Prevention Plan (APP) as an appendix (APP/SSHP). Address all occupational safety and health hazards (traditional construction as well as contaminant-related hazards) associated with cleanup operations within the APP/SSHP. Cover each SSHP element in Section 28.A.01 of EM 385-1-1 and each APP element in Appendix A of EM 385-1-1. There are overlapping elements in Section 28.A.01 and Appendix A of

SECTION 01 35 29.13 Page 5

EM 385-1-1. SSHP appendix elements that overlap with APP elements need not be duplicated in the APP/SSHP provided each SOH issue receives adequate attention and is documented in the APP/SSHP.

The APP/SSHP is a dynamic document, subject to change as project operations/execution change. The APP/SSHP will require modification to address changing and previously unidentified health and safety conditions. It is the Contractor's responsibility to ensure that the APP/SSHP is updated accordingly.

Submit amendments to the APP/SSHP to the COR as the APP/SSHP is updated. For long duration projects resubmit the APP/SSHP to the COR annually for review. The APP/SSHP must contain all updates.

1.6.1 Acceptance and Modifications

Prior to submittal, the APP/SSHP must be signed and dated by the Safety and Health Manager and the Site Superintendent. Submit for review 30 days prior to the Preconstruction Safety Conference.

Deficiencies in the APP/SSHP will be discussed at the preconstruction safety conference, and be revised to correct the deficiencies and resubmitted for acceptance. Onsite work must not begin until the plan has been accepted. Maintain a copy of the written APP/SSHP onsite. Changes and modifications to must be made with the knowledge and concurrence of the Safety and Health Manager, the Site Superintendent, and the Contracting Officer. Bring to the attention of the Safety and Health Manager, the Site Superintendent, and the Contracting Officer any unforeseen hazard that becomes evident during the performance of the work, through the Site Safety and Health Officer (SSHO) for resolution as soon as possible. In the interim, take necessary action to re-establish and maintain safe working conditions in order to safeguard onsite personnel, visitors, the public, and the environment.

Disregard for the provisions of this specification or the accepted APP/SSHP will be cause for stopping work until the matter has been rectified.

1.6.2 Availability

Make available the APP/SSHP in accordance with 29 CFR 1910.120, (b) (1) (v) and 29 CFR 1926.65,

(b) (1) (v).

1.7 SITE DESCRIPTION AND CONTAMINATION CHARACTERIZATION

1.7.1 Project/Site Conditions

Refer to the following reports and information for the site description and contamination characterization as identified on the Delivery Order, which may include but not limited to the following.

1.7.1.1 CERCLA Documents

1.7.1.2 RCRA Documents

1.7.1.3 UST Documents

1.7.2 Ordnance and Explosives (OE)

Stop work and contact the Contracting Officer (CO) if ordnance and explosives (OE), explosive media or chemical agent contaminated media (CACM) are discovered during hazardous waste site cleanup activities. Proceed with work after the CO gives permission and, according to ER 385-1-95 requirements.

SECTION 01 35 29.13 Page 6

1.8 TASK SPECIFIC HAZARDS, INITIAL PPE, HAZWOPER MEDICAL SURVEILLANCE AND

TRAINING APPLICABILITY

Task specific occupational hazards, task specific HAZWOPER medical surveillance and training applicability and task specific initial PPE requirements for the project are listed on the Task Hazard and Control Sheets at the end of this section. It is the Contractor's responsibility to reevaluate occupational safety and health hazards as the work progresses and to adjust the PPE and onsite operations, if necessary, so that the work is performed safely and in compliance with occupational safety and health regulations.

1.9 STAFF ORGANIZATION, QUALIFICATION AND RESPONSIBILITIES

1.9.1 Safety and Health Manager

Safety and Health Manager must be an Industrial Hygienist certified by the American Board of Industrial Hygiene, a safety professional certified by the Board of Certified Safety Professionals, a health physicist certified by the American Board of Health Physicists, or as identified on the Delivery Order.

1) The Safety and Health Manager must have the following additional qualifications:

a. A minimum of 5 years experience in developing and implementing safety and health programs for projects similar to that described on the Delivery Order.

b. Documented experience in supervising professional and technician level personnel.

c. Documented experience in developing worker exposure assessment programs and air monitoring programs and techniques.

d. Documented experience in managing personal protective equipment programs and conducting PPE hazard evaluations for the types of activities and hazards likely to be encountered on the project.

e. Working knowledge of state and Federal occupational safety and health regulations.

2) The Safety and Health Manager will:

a. Be responsible for the development, implementation, oversight, and enforcement of the

APP/SSHP.

b. Sign and date the APP/SSHP prior to submittal.

c. Conduct initial site-specific training.

d. Be present onsite or during remedial activities and at the startup of each new major phase of work.

e. Visit the site as needed for the duration of activities, to audit the effectiveness of the

f. Be available for emergencies.

SECTION 01 35 29.13 Page 7

g. Provide onsite consultation as needed to ensure the APP/SSHP is fully implemented.

h. Coordinate any modifications to the APP/SSHP with the Site Superintendent, the SSHO, and the Contracting Officer.

i. Provide continued support for upgrading/downgrading of the level of personal protection.

j. Be responsible for evaluating air monitoring data and recommending changes to engineering controls, work practices, and PPE.

k. Review accident reports and results of daily inspections.

l. Serve as a member of the Contractor's quality control staff.

1.9.2 Additional Certified Health and Safety Support Personnel

As required by the Delivery Order, retain health physics support from a health physicist certified by the American Board of Health Physics to develop radiation protection requirements of the APP/SSHP and, when necessary, visit the site to help implement ionizing radiation protection requirements of the APP/SSHP. Retain safety support from a safety professional certified by the Board of Certified Safety professionals to develop written occupational safety procedures for the APP/SSHP and, when necessary, visit the site to help implement APP/SSHP requirements. Retain industrial hygiene support from an industrial hygienist certified by the American Board of Industrial Hygiene to develop occupational health practices for the APP/SSHP and, if necessary, visit the site to help implement APP/SSHP requirements.

1.9.3 Site Safety and Health Officer

Designate an individual and one alternate as the Site Safety and Health Officer (SSHO). The name, qualifications (education and training summary and documentation), and include work experience of the Site Safety and Health Officer and alternate in the APP/SSHP.

1). The SSHO must have the following qualifications:

a. A minimum of 2 years experience in implementing safety and health programs at hazardous waste sites, in the hazardous waste disposal industry, at underground storage tank removal projects, in the chemical or petroleum processing industry, and radioactive waste cleanup projects where Level B and Level C personal protective equipment was required.

b. Documented experience in construction techniques and construction safety procedures.

c. Working knowledge of Federal and state occupational safety and health regulations.

d. Specific training in personal and respiratory protective equipment, confined space entry and in the proper use of air monitoring instruments and air sampling methods including monitoring for ionizing radiation.

2). The Site Safety and Health Officer must:

SECTION 01 35 29.13 Page 8

a. Assist and represent the Safety and Health Manager in onsite training and the day to day onsite implementation and enforcement of the accepted APP/SSHP.

b. Be assigned to the site on a full time basis for the duration of field activities. The SSHO can have collateral duties in addition to Safety and Health related duties. If operations are performed during more than 1 work shift per day, a site Safety and Health Officer must be present for each shift and when applicable, act as the radiation safety officer (RSO) as defined in paragraph 06.E.02 of EM 385-1-1 on radioactive waste cleanup projects.

c. Have authority to ensure site compliance with specified safety and health requirements, Federal, state and OSHA regulations and all aspects of the APP/SSHP including, but not limited to, activity hazard analyses, air monitoring, monitoring for ionizing radiation, use of PPE, decontamination, site control, standard operating procedures used to minimize hazards, safe use of engineering controls, the emergency response plan, confined space entry procedures, spill containment program, and preparation of records by performing a daily safety and health inspection and documenting results on the Daily Safety Inspection Log in accordance with 29

CFR 1904.

d. Have authority to stop work if unacceptable health or safety conditions exist, and take necessary action to re-establish and maintain safe working conditions.

e. Consult with and coordinate any modifications to the APP/SSHP with the Safety and Health Manager, the Site Superintendent, and the Contracting Officer.

f. Serve as a member of the Contractor's quality control staff on matters relating to safety and health.

g. Conduct accident investigations and prepare accident reports.

h. Conduct daily safety inspection and document safety and health findings into the Daily Safety Inspection Log. Track noted safety and health deficiencies to ensure that they are corrected.

i. In coordination with site management and the Safety and Health Manager, recommend corrective actions for identified deficiencies and oversee the corrective actions.

1.9.4 Occupational Physician

Use the services of a licensed physician, who is certified in occupational medicine by the American Board of Preventative Medicine, or who, by necessary training and experience is Board eligible. The physician must be familiar with this site's hazards and the scope of this project. Include the medical consultant's name, qualifications, and knowledge of the site's conditions and proposed activities in the APP/SSHP. The physician will be responsible for the determination of medical surveillance protocols and for review of examination/test results performed in compliance with 29 CFR 1910.120, (f) and 29 CFR 1926.65, (f) and paragraph MEDICAL SURVEILLANCE.

1.9.5 Persons Certified in First Aid and CPR

At least two persons who are currently certified in first aid and CPR by the American Red Cross or other approved agency must be onsite at all times during site operations. They must be trained in universal precautions and the use of PPE as described in the Blood borne Pathogens Standard of 29

SECTION 01 35 29.13 Page 9

CFR 1910, Section .1030. These persons may perform other duties but will be immediately available to render first aid when needed.

1.9.6 Safety and Health Technicians

For each work crew in the exclusion zone, one person, designated as a Safety and Health technician, must perform activities such as air monitoring, decontamination, and safety oversight on behalf of the SSHO. They must have appropriate training equivalent to the SSHO in each specific area for which they have responsibility and report to and be under the supervision of the SSHO.

1.10 TRAINING

Meet the following requirements in the Contractor's training program for workers performing cleanup operations and who will be exposed to contaminants.

1.10.1 General Hazardous Waste Operations Training

All Personnel performing duties with potential for exposure to onsite contaminants must meet and maintain the following 29 CFR 1910.120/29 CFR 1926.65 (e) training requirements:

a. 40 hours of off-site hazardous waste instruction.

b. 3 days actual field experience under the direct supervision of a trained, experienced supervisor.

c. 8 hours refresher training annually.

Onsite supervisors must have an additional 8 hours management and supervisor training specified in 29 CFR 1910.120/29 CFR 1926.65 (e) (4).

1.10.2 Pre-entry Briefing

Prior to commencement of onsite field activities, all site employees, including those assigned only to the Support Zone, must attend a site-specific safety and health training session. This session will be conducted by the Safety and Health Manager and the Site Safety and Health Officer to ensure that all personnel are familiar with requirements and responsibilities for maintaining a safe and healthful work environment. Thoroughly discuss procedures and contents of the accepted APP/SSHP and Sections 01.B.02 and 28.D.03 of EM 385-1-1. Each employee must sign a training log to acknowledge attendance and understanding of the training. Notify the Contracting Officer at least 5 days prior to the initial site-specific training session so government personnel involved in the project may attend.

1.10.3 Periodic Sessions

Conduct periodic onsite training by the SSHO at least weekly or as required for personnel assigned to work at the site during the following week or day. Address safety and health procedures, work practices, any changes in the APP/SSHP, activity hazard analyses, work tasks, or schedule; results of previous week's air monitoring, review of safety discrepancies and accidents. Convene a meeting prior to implementation of the change must be convened should an operational change affecting onsite field work be made, to explain safety and health procedures. Conduct a site-specific training sessions for new personnel, visitors, and suppliers by the SSHO using the training curriculum outlines developed by the Safety and Health Manager. Each employee must sign a training log to acknowledge attendance and understanding of the training.

SECTION 01 35 29.13 Page 10

1.10.4 Other Training

Site specific training for sites where radioactive wastes are to be cleaned up include:

a. Site specific procedures for handling and storing radioactive materials;

b. Health and safety hazards associated with exposure to the radioactive material that will be cleaned up or otherwise handled and the purpose and function of protective devices and precautions used to minimize exposures;

c. Elements of the APP/SSHP and company specific procedures intended to provide protection from radiation exposure;

d. Worker responsibility to report any unsafe acts which might result in exposure to ionizing radiation;

e. Appropriate worker response procedures to events that may result in worker exposure to ionizing radiation;

f. Worker rights and responsibilities with respect to ionizing radiation exposure. Provide training as specified by 29 CFR 1910 Section .146, by the Safety and Health Manager shall for employees who are required to supervise, standby, or enter permit-required confined spaces. Train in accordance with 49 CFR 172 Subpart, Persons involved in any aspect of the transportation of hazardous materials.

1.11 PERSONAL PROTECTIVE EQUIPMENT

1.11.1 Site Specific PPE Program

Provide onsite personnel exposed to contaminants with appropriate personal protective equipment.

Components of levels of protection (B, C, D, and modifications) must be relevant to site-specific conditions, including heat and cold stress potential and safety hazards. Use only respirators approved by NIOSH. Commercially available PPE, used to protect against chemical agent, must be approved by the director of Army Safety through the Chemical Agent Safety and Health Policy Action Committee (CASHPAC). Keep protective equipment and clothing clean and well maintained. Include site-specific procedures to determine PPE program effectiveness and for onsite fit-testing of respirators, cleaning, maintenance, inspection, and storage of PPE within the PPE section of the APP/SSHP.

1.11.2 Levels of Protection

The Safety and Health Manager must establish and evaluate as the work progresses the levels of protection for each work activity. Also establish action levels for upgrade or downgrade in levels of PPE. Describe in the SSHP the protocols and the communication network for changing the level of protection. Address air monitoring results, potential for exposure, changes in site conditions, work phases, job tasks, weather, temperature extremes, individual medical considerations, etc., within the PPE evaluation protocol.

1.11.2.1 Initial PPE Components

Initial minimum protective clothing and equipment ensembles required are as described on the Delivery Order.

SECTION 01 35 29.13 Page 11

1.11.3 PPE for Government Personnel

A minimum of three clean sets of personal protective equipment and personal dosimeters for work on radioactive waste cleanup sites and clothing (excluding air-purifying negative-pressure respirators and safety shoes, which will be provided by individual visitors), as required for entry into the Exclusion Zone and/or Contamination Reduction Zone, must be available for use by the Contracting Officer or official visitors. The items must be cleaned and maintained by the Contractor and stored in the clean room of the decontamination facility and clearly marked: "FOR USE BY GOVERNMENT ONLY."

Provide basic training in the use and limitations of the PPE provided.

1.12 MEDICAL SURVEILLANCE PROGRAM

Meet 29 CFR 1910.120/29 CFR 1926.65 (f) and the following requirements for medical surveillance program for workers performing cleanup operations and who will be exposed to contaminants. Assure the Occupational Physician or the physician's designee performs the physical examinations and reviews examination results. Participation in the medical surveillance program will be without cost to the employee, without loss of pay and at a reasonable time and place.

1.12.1 Frequency of Examinations

Medical surveillance program participants must receive medical examinations and consultations on the following schedule.

a. Every 12 months.

b. If and when the participant develops signs and symptoms indicating a possible overexposure due to an uncontrolled release of a hazardous substance on the project.

c. Upon termination or reassignment to a job where medical surveillance program participation is not required, unless his/her previous annual examination/consultation was less than 6 months prior to reassignment or termination.

d. On a schedule specified by the occupational physician.

1.12.2 Content of Physical Examinations/Consultation

Verify the following information about medical surveillance program participants.

a. Baseline health conditions and exposure history.

b. Allergies/sensitivity/susceptibility to hazardous substances exposure.

c. Ability to wear personal protective equipment inclusive of NIOSH certified respirators under extreme temperature conditions.

d. Fitness to perform assigned duties.

Provide the occupational physician with the following information for each medical surveillance program participant.

SECTION 01 35 29.13 Page 12

a. Information on the employee's anticipated or measured exposure.

b. A description of any PPE used or to be used.

c. A description of the employee's duties as they relate to the employee's exposures (including physical demands on the employee and heat/cold stress).

d. A copy of 29 CFR 1910.120, or 29 CFR 1926.65.

e. Information from previous examinations not readily available to the examining physician.

f. A copy of Section 5.0 of NIOSH 85-115.

g. Information required by 29 CFR 1910 Section .134.

1.12.3 Physician's Written Opinion

Obtain and furnish to the Safety and Health Manager; and the employee before work begins, a copy of the physician's written opinion for each employee. Address the employee's ability to perform hazardous waste site remediation work and containing the following.

a. The physician's verification of the employee's fitness to perform duties as well as recommended limitations upon the employee's assigned work and/or PPE usage.

b. The physician's opinion about increased risk to the employee's health resulting from work; and

c. A statement that the employee has been informed and advised about the results of the examination.

1.12.4 Employee Certificates

Provided on employee certificates, documentation that employees have received medical examinations.

1.12.5 Site Specific Medical Surveillance

Prior to onsite work, medical surveillance program participants must undergo medical testing as indicated on the Delivery Order. Provide an explanation of the site specific medical surveillance testing in the APP/SSHP.

1.13 EXPOSURE MONITORING/AIR SAMPLING PROGRAM

Prepare and implement by the Safety and Health Manager an exposure monitoring/air sampling program to identify and quantify safety and health hazards and airborne levels of hazardous substances in order to assure proper selection of engineering controls, work practices and personal protective equipment for affected site personnel. Include action levels for upgrading/downgrading PPE in the program. Monitor gasses and vapors as indicated on the Delivery Order. Monitor for the following aerosolized contaminants.

1.13.1 Ionizing Radiation Sampling and Dosimetry

1.13.1.1 Air Sampling and Dosimeter

SECTION 01 35 29.13 Page 13

Instruments, and sampling methods, and dosimeters to evaluate occupational exposure to radioactive isotopes and ionizing radiation fields shall be as indicated on the Delivery Order.

1.13.1.2 Evaluation

Radiation dosimetry must be evaluated by an individual or company holding current personnel dosimetry accreditation from the National Voluntary Laboratory Accreditation Program (NVLAP).

Electronic dosimetry may be used to assign external dose if approved by the Contracting Officer.

Internal intake assessment and applicable monitoring must be evaluated by the CHP.

1.13.1.3 Documentation

Document employee exposure to external radiation. Include reviewing each employee's radiation exposure history in accordance with 10 CFR 20 Section .2104, for compliance with exposure standards prior to allowing the employee access to a restricted area. If the employee has no exposure history, the employee must provide a signed written statement to that effect.

1.13.1.4 Reporting

Furnish reports of exposure to ionizing radiation to the Contracting Officer as soon as available and to each employee annually, upon termination, and within 30 days of any personal request.

1.14 HEAT STRESS MONITORING AND MANAGEMENT

Document in the APP/SSHP and implement the procedures and practices in section 06.J. in EM 385-1- 1 to monitor and manage heat stress.

1.15 SPILL AND DISCHARGE CONTROL

Develop and implement written spill and discharge containment/control procedures. Address radioactive wastes, shock sensitive wastes, laboratory waste packs, material handling equipment, as well as drum and container handling, opening, sampling, shipping and transport. Describe prevention measures, such as building berms or dikes; spill control measures and material to be used (e.g. booms, vermiculite); location of the spill control material; personal protective equipment required to cleanup spills; disposal of contaminated material; and who is responsible to report the spill. Storage of contaminated material or hazardous materials must be appropriately bermed, diked and/or contained to prevent any spillage of material on uncontaminated soil. If the spill or discharge is reportable, and/or human health or the environment are threatened, the National Response Center, the state, and the Contracting Officer must be notified as soon as possible. Reporting requirements must be in accordance with Section 02 65 00 UNDERGROUND STORAGE TANK REMOVAL.

1.16 MATERIALS TRANSFER SAFETY

Remove liquids and residues from the tanks using explosion-proof or air-driven pumps. Bond to the tank and ground pump motors and suction hoses to prevent electrostatic ignition hazards. Use of a hand pump will be permitted to remove the last of the liquid from the bottom of the tanks. If a vacuum truck is used for removal of liquids or residues, the area of operation for the vacuum truck must be vapor free. locate the truck upwind from the tank and outside the path of probable vapor travel.

Discharge the vacuum pump exhaust gases through a hose of adequate size and length downwind of the truck and tank area. Vacuum truck operating and safety practices must conform to API RP 2219.

Collect tank residues in drums, tanks, or tank trucks labeled according to 49 CFR 171 and 49 CFR 172

SECTION 01 35 29.13 Page 14 and disposed of as specified. Disconnect and drain fittings and lines of their contents after the materials have been transferred and the tanks have been exposed. Do not spill contents into the environment during cutting or disconnecting of tank fittings. Transfer materials drained into DOT-approved drums for storage and/or transportation. Only non-sparking or non-heat producing tools shall be used to disconnect and drain or to cut through tank fittings. Electrical equipment (e.g., pumps, portable hand tools, etc.) used for tank preparation must be explosion-proof. Following cutting or disconnecting of the fittings, plug openings leading to the tanks.

1.17 DRUM AND CONTAINER HANDLING

Procedures and Precautions (opening, sampling, over packing) as described on the Delivery Order.

1.18 CONFINED SPACE ENTRY PROCEDURES

As described on the Delivery Order.

1.19 HOT WORK

Hot work will not be permitted on or within the tanks or anywhere else not previously specified as a hot work area, except as outlined herein. Prior to conducting hot work, a hot work permit must be prepared by the person to be conducting the hot work and reviewed and signed off by the Contractor's qualified person. An additional hot work permit may need to be obtained from local authorities or in the case of military or other federal installations, the fire marshal. An example format for a hot work permit must be included in the AAPP/SSHP. Describe compliance with the following procedures.

After tank interiors have been decontaminated, hot work may be conducted only when the tank is inerted, and to the extent necessary to begin dismantling the tanks. After decontamination of tank interiors, hot work must not be performed unless monitoring indicates atmospheres within and immediately surrounding the tanks are less than 8% oxygen inside the tank and less than 10 percent of the LFL outside the tank; continuous monitoring must continue until the hot work is completed. The hot work prohibition includes welding, cutting, grinding, sawing, or other similar operations which could be expected to potentially generate combustion-producing temperatures or sparks, or which could produce potentially hazardous fumes or vapors. Designate an individual at each hot work site as a fire watch. This person's sole responsibility is to monitor the hot work and have immediate access to the fire extinguisher located at each hot work site. A new permit must be obtained at the start of each work shift during which hot work will be conducted.

1.20 IGNITION SOURCES

1.21 FIRE PROTECTION AND PREVENTION

1.22 ELECTRICAL SAFETY

1.23 EXCAVATION AND TRENCH SAFETY

SECTION 01 35 29.13 Page 15

1.24 GUARDING OF MACHINERY AND EQUIPMENT

1.25 LOCKOUT/TAGOUT

1.26 FALL PROTECTION

1.27 HAZARD COMMUNICATION

1.28 ILLUMINATION

1.29 SANITATION

1.30 ENGINEERING CONTROLS

1.31 PROCESS SAFETY MANAGEMENT

1.32 SIGNS AND LABELS

1.33 WASTE DISPOSAL

1.34 TANK PURGING FOR PERMIT-REQUIRED CONFINED SPACE ENTRIES

Purge tanks for confined space entry. Reduce the flammable vapors to less than 10 percent of the LFL and the oxygen content be between 19.5 percent and 23.5 percent. Do not attempt confined space entry into the tanks unless absolutely necessary, as for example, to remove sludge from the tank. Flammable vapors may be exhausted from the tank by any of the methods from API RP 1604 listed below, or any method approved by the Contracting Officer. Specify the purging method to be used within the

SECTION 01 35 29.13 Page 16

a. Ventilation by Eductor-Type Air Movers: Properly bond and ground the eductor-type air mover to prevent the generation and discharge of static electricity. When using this method, the fill (drop) tube must remain in place to ensure ventilation at the bottom of the tank. Tanks equipped with fill (drop) tubes that are not removable must be purged by this method. Use an eductor extension to discharge vapors a minimum of 12 feet above grade or 3 feet above adjacent roof lines, whichever is greater. If this is not possible, propose and get approved alternative methods prior to purging. Noise levels generated by these devices as a result of high airflow may exceed OSHA PELs. Evaluate noise levels and provide appropriate hearing protection.

b. Ventilation by Diffused Air Blowers: When using this purging method, the air-diffusing pipe is properly bonded and grounded to prevent the discharge of a spark. Fill (drop) tubes must be removed to allow proper diffusion of the air in the tank. Air supply must be from a compressor that has been checked to ensure that Grade D breathing air is being supplied. Air pressure in the tank must not exceed 5 psi gauge to avoid tank failure.

c. Commercial Emulsifiers and Volatile Fuel Encapsulators: These products are completely miscible in water, aid in the elimination of flammable vapors, and are biodegradable. Determine prior to using this method, regulatory requirements for treatment and disposal of the water. Standing outside the tank, rinse the tank with a 3-to-6 percent solution of the product using a pressure sprayer through a tank opening. Measure explosive concentrations at several levels (top, middle, and bottom) within the tank. If readings are greater than 10 percent of the LFL, rinse the tank again. When LFL readings are acceptable, pump the water in the tank for disposal.

1.35 TANK INERTING (NO ENTRY)

Following the removal of tank contents but prior to excavation and removal of the tank(s) and tank preparation activities, inert the tank(s) only by introducing an inert gas, carbon dioxide (CO2) or liquid nitrogen (N2), to remove flammable vapors. Before inerting, plug all openings in the tanks with threaded or expansion type plugs except the vent tube and the opening to be used for introducing the inert gas. Within 30 minutes prior to initiating any activities (e.g., excavating, preparation, removal, opening, demolition, transportation, or other similar activities) involving a tank which has been inerted, the inerted nature of the tank (oxygen levels less than 8%) must be verified.

a. Do not use CO2 fire extinguishers for inerting the tank interiors. If a compressed gas (e.g., CO2 or

N2) is introduced into the tank the following requirements must be met to prevent the buildup of static electricity:

(1) Bond together and ground the UST and the compressed gas supply tank.

(2) Supply the compressed gas only at low flows.

(3) Release the liquid or gas at the tank bottom so that static electricity is not generated by liquid falling to the bottom of the tank. Slowly fill the tank from the bottom up.

b. If used, introduce dry ice, which evolves CO2 gas as it evaporates, in the amount of at least 3 lbs per

100 gallons of tank capacity. Prevent skin contact with dry ice by wearing heavy cloth gloves.

c. Introduce sufficient quantities of inert gas (CO2 or N2) into the tanks to lower the oxygen content to less than 8 percent. Do not exceed5 psi pressure inside the tank. Prior to proceeding with additional activities on the tank (e.g., excavating), the oxygen content of the tanks must be monitored to confirm that it is less than 8 percent. Conduct additional oxygen level monitoring at

SECTION 01 35 29.13 Page 17 least hourly while activities involving the tanks are underway but prior to decontamination of tank interiors; at least daily during periods in which the tanks are not being disturbed but prior to decontamination of their interiors; or as directed by the Contracting Officer. If monitoring of tank interiors indicates that oxygen levels are not remaining below 8 percent, introduce additional inert gas and initiate more frequent oxygen monitoring.

d. During inerting procedures, use an extension vent tube a minimum of 12 feet above grade or 3 feet above any adjacent (within 75 feet) roof lines, whichever is greater to discharge tank vapors. If this is not possible, propose and get approved alternative methods prior to inerting. Conduct continuous combustible gas/oxygen monitoring shall be conducted at the vent and inert gas introduction holes.

1.36 TANK ATMOSPHERE TESTING

Monitor the air within the storage tanks to ensure the space is either adequately purged and safe for personnel entry, or to ensure the tank has been adequately inerted and the oxygen content is less than 8 percent. In both instances, perform monitoring at the top, bottom, and middle areas of the tanks to ensure stratification has not occurred. Report monitoring results to project personnel to ensure safe operations. Record data as specified in paragraph EXPOSURE MONITORING/AIR SAMPLING

PROGRAM.

1.36.1 Monitoring to Ensure Purging

When monitoring to ensure purging, both oxygen content and LFL readings are required. Prior to obtaining LFL readings, monitor the oxygen content of the space and verify that the combustible gas indicators are operating within the oxygen limits identified by the CGI manufacturer. Do not permit personnel to enter spaces with oxygen levels are less than 19.5 percent, except in emergencies, and then only when equipped with the proper PPE and when following permit-required confined space entry procedures. Monitor toxic air contaminants as specified in paragraph EXPOSURE

MONITORING/AIR SAMPLING PROGRAM.

1.36.2 Monitoring to Ensure Inerting

Monitor inerted tanks to ensure oxygen readings remain below a maximum allowable percentage of 8 percent by volume.

1.37 TANK LIFTING

Lift tanks using equipment with a rated capacity greater than the load to be lifted. Lift tanks by lifting eyes or by straps under the ends of the tanks. Do not lift by the manhole flange or by removing the bungs. Direct personnel to remain away from the ends of the tanks and position tanks, whenever possible, with the ends oriented away from occupied or traveled areas, due to potential for rupture.

During transportation, secure the tanks to prevent movement.

1.38 TANK DEMOLITION

Demolish excavated tanks before being removed from the site unless they are transported directly to a state certified tank destruction facility. Demolition will not be permitted until a decontamination of the interiors and exteriors is complete. Demolition must involve opening the tanks sufficiently to permanently prohibit further use as containers of liquids. Tanks must be inerted and tested before they

SECTION 01 35 29.13 Page 18 are opened. Submit plans and procedures in the APP/SSHP, including a list of materials and supplies, for safely and effectively demolishing the tanks.

1.39 TANK CLEANING

conform to API Std 2015 for safety practices and procedures for the cleaning of the storage tanks.

Conduct opening of the tanks to permit decontamination utilizing only methods approved in the APP/SSHP. Decontaminate the interior and exterior of the tank prior to removing it from the work site unless the tank is being transported directly to a state certified tank destruction facility. Submit plans and procedures in the SSHP, including materials and supplies, for safely and effectively opening the tanks, cleaning surfaces of the interior and exterior of the tanks, and disposing of the decontamination fluids. Volatile organic solvents are not permitted to be utilized for decontamination procedures.

Personnel must not enter any of the storage tanks as a part of this project, except when following permit-required confined space entry procedures. Collect and dispose of decontamination fluids.

Upon completion of this project, written certification must be made that the tank was properly decontaminated prior to being removed from the site.

1.40 SITE CONTROL MEASURES

1.40.1 Work Zones

Initial anticipated work zone boundaries (exclusion zone, contamination reduction zone, support zone, all access points and decontamination areas) are to be clearly delineated on the site drawings. Base delineation of work zone boundaries on the contamination characterization data and the hazard/risk analysis to be performed as described in paragraph: HAZARD/RISK ANALYSIS. As work progresses and field conditions are monitored, work zone boundaries may be modified (and site drawings modified) with approval of the Contracting Officer. Clearly identify work zones and marked in the field (using fences, tape, signs, etc.). Post a site map, showing work zone boundaries and locations of decontamination facilities in the onsite office. Work zones must consist of the following:

a. Exclusion Zone (EZ): The exclusion zone is the area where hazardous contamination is either known or expected to occur and the greatest potential for exposure exists. Control entry into this area and exit may only be made through the CRZ.

b. Contamination Reduction Zone (CRZ): The CRZ is the transition area between the Exclusion Zone and the Support Zone. The personnel and equipment decontamination areas must be separate and unique areas located in the CRZ.

c. Support Zone (SZ): The Support Zone is defined as areas of the site, other than exclusion zones and contamination reduction zones, where workers do not have the potential to be exposed to hazardous substances or dangerous conditions resulting from hazardous waste operations. Secure the Support Zone against active or passive contamination. Site offices, parking areas, and other support facilities must be located in the Support Zone.

1.40.2 Site Control Log

A log of personnel visiting, entering, or working on the site must be maintained. Include the following:

date, name, agency or company, time entering and exiting site, time entering and exiting the exclusion zone (if applicable). Before visitors are allowed to enter the Contamination Reduction Zone or Exclusion Zone, they must show proof of current training, medical surveillance and respirator fit

SECTION 01 35 29.13 Page 19 testing (if respirators are required for the tasks to be performed) and fill out a Certificate of Worker or Visitor Acknowledgment. Record this visitor information, including date, in the log.

1.40.3 Communication

Provide and install an employee alarm system that has adequate means of on and off site communication in accordance with 29 CFR 1910 Section .165. The means of communication must be able to be perceived above ambient noise or light levels by employees in the affected portions of the workplace. The signals must be distinctive and recognizable as messages to evacuate or to perform critical operations.

1.40.4 Site Security

Provide site security as required by the Delivery Order. Print signs in bold large letters on contrasting backgrounds. Signs must be visible from all points where entry might occur and at such distances from the restricted area that employees may read the signs and take necessary protective steps before entering.

1.41 PERSONAL HYGIENE AND DECONTAMINATION

Personnel entering the Exclusion or Contamination Reduction Zones or otherwise exposed to hazardous chemical vapors, gases, liquids, or contaminated solids must decontaminate themselves and their equipment prior to exiting the contamination reduction zone (CRZ) and entering the support zone.

Consult Chapter 10.0 of NIOSH 85-115 when preparing decontamination procedures. Submit a detailed discussion of personal hygiene and decontamination facilities and procedures to be followed by site workers as part of the APP/SSHP. Train employees in the procedures and enforce the procedures throughout site operations.

1.41.1 Decontamination Facilities

Initially set up a decontamination line in the CRZ. Employees must exit the exclusion zone through the CRZ and implement the following decontamination procedures and techniques: Scrub and rinse water proof outer garments, remove all outer garments, hand and face wash, and shower. Showers, if needed, must comply with 29 CFR 1910, Section.141 and EM 385-1-1, 02 C, Washing Facilities. It is the Site Safety and Health Officer's responsibility to recommend techniques to improve personnel decontamination procedures, if necessary.

1.41.2 Equipment Decontamination

Decontaminate the vehicles and equipment used in the EZ shall be decontaminated in the CRZ prior to leaving the site.

1.41.2.1 Facilities for Equipment and Personnel

Provide a vehicle/equipment decontamination station within the CRZ for decontaminating vehicles and equipment leaving the EZ. Construct a decontamination station pad, which meets the site decontamination needs for all vehicles and larger equipment decontamination. Construct the pad to capture decontamination water, including overspray, and allow for collection and removal of the decontamination water using sumps, dikes and ditches as required. High pressure, low volume, water wash area for equipment and vehicles. A steam cleaning system for use after the mud and/or site material has been cleaned from the equipment. Dry decontamination using a broom to remove

SECTION 01 35 29.13 Page 20 dry/loose spilled materials on accessible surfaces. A designated "clean area" in the CRZ for performing equipment maintenance. Use this area when personnel are required by normal practices to come in contact with the ground, i.e., crawling under a vehicle to change engine oil. Equipment within the EZ or CRZ must be decontaminated before maintenance is performed.

1.41.2.2 Procedures

Procedures for equipment decontamination must be developed and used to prevent the spread of contamination into the SZ and offsite areas. These procedures must address disposal of contaminated products and spent materials used on the site, including containers, fluids, oils, etc. Assume any item taken into the EZ to be contaminated and perform an inspection and decontaminate. Vehicles, equipment, and materials must be cleaned and decontaminated prior to leaving the site. Handle construction material in such a way as to minimize the potential for contaminants being spread and/or carried offsite. Prior to exiting the site, vehicles and equipment must be monitored to ensure the adequacy of decontamination.

1.42 EMERGENCY EQUIPMENT AND FIRST AID REQUIREMENTS

Maintain, as a minimum, the following items onsite and available for immediate use:

a. First aid equipment and supplies approved by the consulting physician.

b. Emergency eyewashes and showers that comply with ISEA Z358.1.

c. Emergency-use respirators. For escape purposes, supply 5- to 15-minute emergency escape masks as required for the project. For rescue purposes, Supply two positive pressure self-contained breathing apparatus (SCBA). Dedicate these for emergency use only and maintained onsite in the Contamination Reduction Zone.

d. Provide fire extinguishers of sufficient size and type at site facilities and in all vehicles and at any other site locations where flammable or combustible materials present a fire risk.

1.43 EMERGENCY RESPONSE AND CONTINGENCY PROCEDURES

An Emergency Response Plan, that meets the requirements of 29 CFR 1910.120 (l) and 29 CFR

1926.65 (l), must be developed and implemented as a section of the APP/SSHP. In the event of any emergency associated with remedial action, without delay, alert all onsite employees and as necessary offsite emergency responders that there is an emergency situation; take action to remove or otherwise minimize the cause of the emergency; alert the Contracting Officer; and institute measures necessary to prevent repetition of the conditions or actions leading to, or resulting in, the emergency.