MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2)
MEO NO.
DATE PAGE 1 of
TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:
Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°
APPLICABILITY CSI Critical Characteristic Affected?
Impact Statement Attached?
REFERENCES FOR RDECOM USE ONLY
DOCUMENT(S) AFFECTED
PURPOSE OR PROBLEM
PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE
MED FORM 5-DEC-09 1401-R-E
B 2142 Oct 15, 2015 2
UH-60A/L Tail Rotor Blade Assembly, 70101-11200-044 (NSN 1615-01-088-3230), 70101-31000-043 (NSN 1615-01-113-8188) - added alternative COTS cut-out wire for removal of centering plug (70101-11104-101)
Administrative
INTERIM USE OF THIS MEO IS AUTHORIZED
UNTIL AFFECTED DOCUMENT IS UPDATED.
MEO CHANGE TYPE
4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY
UH60 DAA
DMWR 1-1615-287 (30 December 2011)
B163243, B167838, B178745
DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None
3-11.7 (Inspection for Bond Voids): Added alternative tap testing methods; 3-13.14 (Replace Spar Plug): moved CAUTION statement before step a (drilling or melting a hole in the spar plug) and added COTS safety glass cut-out wire (new item 121) as alternative to local fabrication of a twisted stainless steel wire handsaw; 4-2.4 (Install Boot): corrected NSN for teflon tape (App C, item 39) per production drawing; added Acetone (ASTM-D329) as approved pre-bond surface cleaning solvent.
GRZELECKI.DAN
IEL.P.125929525
Digitally signed by
GRZELECKI.DANIEL.P.1259295250
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=GRZELECKI.DANIEL.P.1259295250 Date: 2015.10.13 11:02:40 -05'00'
GONZALEZ.JAC
OB.A.145582119
Digitally signed by
GONZALEZ.JACOB.A.1455821190
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=GONZALEZ.JACOB.A.1455821190 Date: 2015.10.09 10:11:07 -05'00'
Jacob Gonzalez
HORN.REINHOL
D.J.1087783495
Digitally signed by
HORN.REINHOLD.J.1087783495
DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=HORN.REINHOLD.J.1087783495 Date: 2015.10.13 11:19:05 -05'00'
Daniel Grzelecki Ron Horn PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT
CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
3-32
3-11.7.1
3-11.7.1 .d.
REPLACE 3-11.7.1 with the following:
"Void Inspection Method. A coin, as described below, or similar device such as a small hammer, may be used for tap testing to determine the size and shape of bond separations, as indicated by a dead sound, between skin and honeycomb core and skin and abrasion strip bond areas. Alternative tap testing tools must be capable of identifying local flaws with the same degree of accuracy as the coin and have round smooth edged of sufficient radius to prevent damaging the material when tap testing. Tap testing shall be performed by experienced personnel."
ADD new paragraph d. as follows:
"Ultrasonic devices may be used to supplement tap testing for bond separation, especially in cases where tap testing is inconclusive, provided reliability of this method has been established."
Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211
MED FORM 18 NOV 2014
W58RGZ-17-R-0237
Attachment 0012
MAINTENANCE ENGINEERING ORDER
(AMCOM Reg. 750-2) Continuation Sheet
MEO NO.
PAGE of
WP NO. PAGE
NO.
PARA-
GRAPH
FIGURE/
TABLE
NO.
CHANGES
(EXACT WORDING OF CHANGES MUST BE GIVEN)
MED FORM 15-DEC-09 1401-R-E
3-93 & 3-94
C-1
C-7(C-8 blank
C-3
3-13.14.
a.
3-13.14.
a.(2)
Table C-1.
RELOCATE "CAUTION" presently located after step a, to before step a.
ADD step a.(2) as follows:
"(2) Prefabricated safety glass cut-out wire (App C, item 121) may be used as an alternative to local fabrication of a twisted stainless steel wire hand-saw."
ADD the following items:
ITEM NATIONAL STOCK DESCRIPTION U/M
NUMBER NUMBER
4 6810-00-223-2739 Acetone, ASTM-D329 PT
121 Tightwire Auto Glass RL Cut-Out Wire, TW 72
(Equalizer) or equivalent
CHANGE the the NSN for item 39 to the following:
ITEM NATIONAL STOCK DESCRIPTION U/M
NUMBER NUMBER
39 5970-00-812-7387 Teflon Tape RL
TG8105 (71643)
MED FORM 18 NOV 2014