This document provides details for an unrestricted invitation for bid for the construction of an F-35 three bay specialized hangar at Truax Field in Madison, Wisconsin. The project scope includes demolishing an existing building and constructing a new 31,000 square foot three bay hangar with associated administrative and shop spaces to accommodate fuel cell operations, indoor wash requirements, squadron level surface coating operations, and weapons load training. The facility will also require a lightning protection system, fall protection, and an Advantor security system. The base contract line items include construction of the new hangar and demolition work. There are also two options related to adding a paint/mix addition and aircraft rated pavement. Interested contractors must register in the System for Award Management and can access the solicitation and plans on SAM.gov. The pre-bid conference will be held on-site at Truax Field and bids are due in accordance with FAR Subpart 14.4. The contract duration is 550 days from notice to proceed. The estimated value is between $25-100 million.
View the file
Other files for this federal contract opportunity
Show all 50
F-35 THREE BAY SPECIALIZED HANGAR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACU
MONACO MAAP-X
ROOM 125
120VSPD
LOC
LOC
120B
MM MM
VS WF
125 125
WP-1
MM
VS
MM
PS
PA-1
MM
VS
MM
PS
PA-2
MM
VS
MM
PS
PA-3
RTU-01 DOAS-01
MMRSFACU - ALARM (FLAME DETECTOR)
MMRSFACU - PREACTION SYSTEM DISCHARGE
MMRSFACU - SUPERVISORY
MMRSFACU - PREACTION SYSTEM DISABLED
MMRSFACU - PREACTION SYSTEM TROUBLE
C WP
TYPICAL NAC CIRCUIT
ANTENNA
LED TEXT
SIGN
CONTROLLER101101101101
EOL
106 106 119 119
119120B128 128 128
MM
MM
MM
PS
L
PS
L
PS
L
MM
PS
H
MM
PS
H
MM
PS
H
SPDWATERFLOW
SPEAKER/ STROBE
W / WATERFLOW SIGN
SPD
(PROVIDE SURGE SUPPRESSION
FOR DEVICES ON BUILDING
EXTERIOR)
1. PROVIDE SURGE SUPPRESSION ON ALL 120 V POWER
SUPPLIES, ANTENNAS, AND CIRCUITS SERVING DEVICES
EXTERIOR TO THE BUILDING, INCLUDING PIV SUPERVISION
AND NOTIFICATION.
2. PROVIDE SMOKE DETECTION AND 120 V POWER FROM FA
CIRCUIT FOR ALL POWER EXTENDER PANELS.
3. PROVIDE ADDITIONAL DEVICES AND APPLIANCES WHERE
NECESSARY TO MEET THE REQUIREMENTS OF THE DESIGN
CRITERIA.
4. PROVIDE REMOTE KEYED TEST SWITCH WITH LED INDICATORS
MAX. 7' AFF AT EACH DUCT SMOKE DETECTOR.
5. ALL FA AND RELEASING SYSTEM DEVICES, APPLIANCES, TERMINAL
BOXES AND THEIR INSTALLATION IN THE HANGAR BAYS SHALL
BE NEMA 4, SUITABLE FOR WET LOCATIONS.
6. RISER DIAGRAM IS DIAGRAMATIC IN NATURE AND ALL CIRCUITS, DEVICES,
APPLIANCES AND EQUIPMENT REQUIRED FOR THIS DELEGATED DESIGN
ARE NOT SHOWN. PROVIDE ADDITIONAL DEVICES, APPLIANCES AND
EQUIPMENT WHERE REQUIRED BY REFERENCED CRITERIA, FOR
COMPLETE AND INTELLIGIBLE SYSTEM.
LOCATE IN 142 IF
OPTION #1 IS NOT
TAKEN
MAU-04
MM
EYEWASH
BID OPTION #1
LOCATE IN 142 IF
OPTION #1 IS NOT
TAKEN
NOTES:
CO
CO
CO
MM
VS
MM
VS
CO
CO
(OPTION
#1)
FFFF
101101101101 F
106126 F
F
119 119 F
120B146 128145 F
F F F F F
CM
CM
CM
CM
FIRE SHUTTERS
P113 P107
CM
HVLS SHUTDOWN
CM
CM
PA
MUTE
CM
CM
GAS SHUTOFF
CM
CM
CCU-02
CM
EF-07
CM
CM
EF-06 EF-03
CM
EHRU-01
CM
MAU-01
CM
CCU-01
CM
EF-04
CM
PCA-03
120B
CM
PCA-02
120B
CM
PCA-01
MM
VS
MM
VS
MM
MM
MM
MM
MM
MM
MM
AED
MM
EYEWASH
MM
VS
KNOX
BOX
KB
CM
HVU-01
CM
EF-09
CM
EF-10
CM
EF-11
WP
CO
(OPTION
#1)
126 144
ROOF ROOF
CM
EHRU-02
F
F
124125 F
128 128 F F
EXP
BFP#1 BFP#2
MM
VS
MMCONTAINMENT LEVEL-NOT EMPTY
MMCONTAINMENT LEVEL-HIGH LEVEL
MMMANUAL TRENCH DRAIN OUTFALL VALVE OPEN
MMMANUAL TRENCH DRAIN OUTFALL VALVE CLOSED
TRENCH DRAIN
OUTFALL
CONTAINMENT
AND MANUAL
VALVE MONITORING
PANEL
SPD
SPD
PIV
FAA
120B
MM
VS
MM
PIV
VS
SPD
FP ROOM
LOW TEMP
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
FSB2020-270-00
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
NWC / JBC
F-
3- Ba y S pe cia liz ed H an ga r M ad iso n, W isc on sin
Ai r N at io na l G ua rd
C
B
A
D
C
B
A
54321
DECEMBER 23, 2021
C :\U sers\aja\D o cum ents\M y R evit\02700_FP_aa ndersN Q
N 9J.rvt
6/7/2022 10:48: 39 AM
FIRE ALARM & MASS
NOTIFICATION SYSTEM RISER
DIAGRAM
FA601
LFO
JME
JME
SCALE:NTS
B3 FIRE ALARM & MASS NOTIFICATION SYSTEM RISER DIAGRAM