8 - Technology Systems.pdf
PDF 1 MB Posted
- Attached to
- Construct Corrosion Control Hangar Federal contract opportunity
- Solicitation number
- W50S8Z20B0001
About this file
This federal solicitation seeks proposals for the construction of a corrosion control hangar at Kingsley Field in Klamath Falls, Oregon. The scope of work includes construction of a pre-engineered metal hangar and adjacent support spaces totaling approximately 16,000 square feet. Additional work includes installation of a chain link security fence, temporary haul road, and lead lining in specified areas. The solicitation will be issued on or around December 3, 2019 with a pre-bid conference on December 12 and bids due by January 6, 2020. The contract is set aside for small businesses with a NAICS code of 236210 and size standard of $36.5 million. The magnitude is estimated between $5-10 million. The performance period is 365 calendar days from notice to proceed. Interested parties must register in the System for Award Management and access plans and specifications through the Federal Business Opportunities website using a Marketing Partner Identification Number password.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attch #3 Revised Specs -Steel Sliding Doors -RFI 047.pdf | ||
| Attch # 2 - Sheet T-011 -RFI 040-41 Response.pdf | ||
| Attch #4 - Revised - Door hardware.pdf | ||
| SF30 Amendment #4.pdf | ||
| Corrosion Control Pre-Bid Minutes 12 Dec.pdf | ||
| SF30 Amendment #3.pdf | ||
| SF30 Amendment #2.pdf | ||
| SF30.pdf | ||
| Sign-In Sheet.pdf | ||
| JA Brand Name - Automated Logic_Redacted.pdf | ||
| 7 - Electrical.pdf | ||
| 6 - Mechanical.pdf | ||
| 2 - Structural.pdf | ||
| W50S8Z20B0001.pdf | ||
| KANGB Corr Control Hgr_Type B3 Revised Bid Spec Vol 3.pdf | ||
| 1 - General and Civil.pdf | ||
| 4 - Fire Alarm and Fire Sprinkler.pdf | ||
| 5 - Plumbing.pdf | ||
| JA Brand Name - Advantor (1)_Redacted.pdf | ||
| 3 - Architectural.pdf | ||
| JA Brand Name - Monaco Fire Alarm_Redacted.pdf | ||
| KANGB Corr Control Hgr_Type B3 Revised Bid Spec Vol 1.pdf | ||
| KANGB Corr Control Hgr_Type B3 Revised Bid Spec Vol 2.pdf |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BET
PB
PP
COM
FO
TGB
TSEM
ACP
IDS
SL
S
V
W
AP
TV
TELECOMMUNICATION OUTLET SYMBOLS
COMMUNICATIONS GROUND BUS BAR
EQUIPMENT RACK
COMMUNICATIONS CABINET
WALL MOUNTED FIBER OPTIC CABINET
COMMUNICATIONS PATCH PANEL
COMMUNICATIONS PUNCH BLOCK
TELEPHONE SERVICE ENTRANCE PROTECTION DEVICE
BUILDING ENTRANCE TERMINAL
SURFACE RACEWAY - REFER TO KEYED
NOTES & SPECIFICATIONS FOR TYPES
MOTION DETECTOR
SECURITY SYSTEM SYMBOLS
VIDEO SURVEILLANCE SYMBOLS
ACCESS CONTROL PANEL
INTRUSION DETECTION SYSTEM
STROBE LIGHT
CAMERA (WALL MOUNTED)
F CAMERA (EXTERIOR CORNER MOUNTED)
CAMERA VIEWING ANGLE
CAM-XX
F - 270°
CAMERA NUMBER
CAMERA LENS TYPE
(PTZ) PAN/TILT/ZOOM CAMERA
(90°) 90° VIEWING ANGLE
(F) FIXED LENS CAMERA
(270°) 270° VIEWING ANGLE
(360°) 360° VIEWING ANGLE
(225°) 225° VIEWING ANGLE
INDICATES GENERAL
DIRECTION OF CAMERA VIEW
F F
DEMOLITION GENERAL NOTES
THE INFORMATION SHOWN IS BASED ON EXISTING DRAWINGS AND SITE
OBSERVATIONS TO ASSIST THE CONTRACTOR IN BIDDING. THE CONTRACTOR
SHOULD VISIT THE SITE TO VERIFY EXISTING CONDITIONS. THE TECHNOLOGY
SYSTEMS DRAWINGS INDICATE EXISTING TECHNOLOGY SYSTEMS ITEMS TO
BE REMOVED. THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OF
WORK REQUIRED AND DO NOT INDICATE EVERY DEVICE, BOX, CONDUIT, WIRE
OR CABLE THAT MUST BE REMOVED.
THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE
TURNING OFF POWER TO TECHNOLOGY SYSTEMS EQUIPMENT OR DEVICES.
COORDINATE ALL OUTAGES WITH THE OWNER. CONDUIT CONCEALED IN
WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY
OTHER CONSTRUCTION.
THIS CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER
CONTRACTORS AT THE JOB SITE BEFORE REMOVING EXISTING TECHNOLOGY
SYSTEMS ITEMS AND INSTALLING NEW ITEMS.
EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE.
RELOCATED EXISTING CONDUIT SHALL NOT BE ALLOWED.
1.
2.
3.
4.
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
WORK PERFORMED INCLUDES ALL LABOR, MATERIAL AND EQUIPMENT
REQUIRED TO INSTALL COMPLETE TECHNOLOGY SYSTEMS AS INDICATED ON
THESE DRAWINGS AND AS SPECIFIED.
ALL TELECOMMUNICATIONS OUTLETS SHALL BE MOUNTED AT HEIGHTS ABOVE
FINISHED FLOOR AS SHOWN IN THE DEVICE MOUNTING HEIGHT DETAIL U.N.O.
SEE ELECTRICAL SPECIFICATIONS FOR LOCATIONS WHERE GRS CONDUIT
SHALL BE USED, OR WHERE IMC, EMT, OR PVC CONDUIT MAY BE USED.
BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE
OFFSET A MINIMUM OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF
FIRE-RATED WALLS SHALL BE OFFSET A MINIMUM OF 24" HORIZONTALLY.
'THRU-THE-WALL' BOXES SHALL NOT BE ALLOWED WITHOUT THE WRITTEN
APPROVAL OF THE ARCHITECT/ENGINEER.
CONTRACTOR SHALL VERIFY ALL EQUIPMENT SIZES AND POWER
REQUIREMENTS FOR EQUIPMENT SUPPLIED BY OTHERS PRIOR TO
INSTALLATION OF CONDUIT.
TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES SHALL BE MOUNTED SO AS TO
ALLOW ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL
MOUNTING OF TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES ON EQUIPMENT
SUPPLIED BY ANOTHER CONTRACTOR SHALL BE COORDINATED WITH AND
APPROVED BY THAT CONTRACTOR IN ADVANCE OF INSTALLATION.
ALL ELECTRICAL CONDUITS AND JUNCTION BOXES SHALL BE CONCEALED.
CONTRACTOR SHALL COORDINATE WITH THE OTHER TRADES AND USE
CHASES AND CEILING SPACES PROVIDED. WHERE BOXES AND CONDUIT ARE
NOTED TO BE INSTALLED EXPOSED, THEY SHALL BE PAINTED TO MATCH THE
SURFACE.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN
WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A
QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL
CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS.
PENETRATIONS THROUGH FLOORS AND FIRE-RATED WALLS SHALL BE
FIRESTOPPED IN A MANNER THAT MAINTAINS THE RATING OF THE FLOOR OR
WALL PENETRATED.
ALL TRENCHING AND BACKFILL FOR BURIED ELECTRICAL CONDUITS SHALL BE
BY THE CONTRACTOR UNLESS NOTED OTHERWISE.
PROVIDE METALLIC TAPE ABOVE BURIED PVC CONDUIT FOR FUTURE
LOCATING.
CONDUIT ROUTED UNDER THE BUILDING SHALL BE MINIMUM 18" BELOW SLAB.
ALL TELEPHONE AND DATA JACKS SHALL BE TERMINATED WITH ALL 4 PAIRS
TO ALLOW FOR INTERCHANGEABILITY.
ALL TELEPHONE AND DATA CABLES SHALL BE INSTALLED IN CONDUIT OR
CABLE TRAY.
ALL CONDUIT STUBS SHALL HAVE PLASTIC OR NYLON BUSHINGS INSTALLED
PRIOR TO THE INSTALLATION OF CABLES.
SITE SYMBOLS
HH HANDHOLE, GENERIC
CABLE MARKERC
CTV CTV PEDISTAL BOX
FO FIBER OPTIC MANHOLE
LINE TYPE KEY
EXISTING TO BE REMOVED BY THIS
CONTRACTOR (DARK DASHED LINE)
EXISTING TO REMAIN WORK
(THIN SOLID LINE)
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDER FLOOR BY
THIS CONTRACTOR
SITE UNDERGROUND CONDUITCON
SITE REMOVED UNDERGROUND
CONDUIT
//CON//
SITE UNDERGROUND FIBER OPTICFOC
SITE REMOVED UNDERGROUND FIBER
OPTIC
//FOC//
SITE UNDERGROUND TELEPHONET
SITE OVERHEAD TELEPHONEOHT
SITE REMOVED TELEPHONE//T//
SITE UNDERGROUND TV CABLETV
TECHNOLOGY SCOPE RESPONSIBILITY MATRIX
ITEM
FLOOR BOX ROUGH-IN, INCLUDING FLOOR BOXES AND CONDUITS
CABLE TRAY, INCLUDING ALL REQUIRED SUPPORT HARDWARE AND FITTINGS
EQUIPMENT ROOM FITTINGS (PER SPECIFICATION SECTION 271100)
EQUIPMENT ROOM POWER RECEPTACLES
GROUNDING OF CABLE TRAY AND EQUIPMENT ROOM COMPONENTS
BACKBONE CABLING, TERMINATION COMPONENTS (e.g. WALL-FIELDS), TERMINATION, TESTING AND LABELING
TECHNOLOGY SYSTEMS ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS, CONDUIT AND SLEEVES
UNDERGROUND CONDUITS IN/OUT OF BUILDING, INCLUDING ASSOCIATED HANDHOLES
PATCH PANELS
TELECOMMUNICATIONS OUTLET (TO) FACEPLATES AND JACKS
HORIZONTAL CABLING, TERMINATIONS, TESTING AND LABELING
GROUND BARS (TMGB, TGB) AND ELECTRICAL SERVICE BONDING
FLOOR BOX AND TELECOMMUNICATION OUTLET (TO) ASSOCIATED POWER RECEPTACLES
SHOWN ON FURNISHED BY INSTALLED BY NOTES
T-SERIES
EQUIPMENT ROOM PLYWOOD WALL COVERINGS
ROOF PENETRATION CONDUITS
INFORMATION DISPLAY SYSTEM HEAD-END COMPONENTS AND MONITOR INTERFACES
INFORMATION DISPLAY SYSTEM AND TV OUTLETS, MOUNTS, DISPLAYS AND CABLING
PA SYSTEM ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
PA SYSTEM COMPONENTS (HEAD-END, MICROPHONES, SPEAKERS/HORNS, VOLUME CONTROLS) AND CABLING
INFORMATION DISPLAY SYSTEM AND TV ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
INFORMATION DISPLAY AND TV LOCATION BLOCKING FOR DISPLAY MOUNT ATTACHMENT/SUPPORT
ACS FIELD DEVICES (e.g. CARD READERS, STATUS SENSORS, REX) AND CABLING
SECURITY SYSTEMS (ACS, VSS) ROUGH-IN, INCLUDING BACKBOXES, TRIM RINGS AND CONDUIT
ACS DOOR HARDWARE INCLUDING ELECTRIC STRIKES, MAGNETIC LOCKS AND ASSOCIATED POWER SUPPLIES
VSS HEAD-END, CAMERAS, MOUNTS AND CABLING
EC 1
E AND T-SERIES EC 2
T-SERIES EC 3
T-SERIES EC OR TC
T-SERIES TC
E-SERIES (PWR) EC
T-SERIES EC
T-SERIES TC
T-SERIES TC
T-SERIES TC
T-SERIES TC
T-SERIES TC
E-SERIES (PWR) EC 5
T-SERIES GC 6
T-SERIES EC 7
T-SERIES EC
T-SERIES
T-SERIES
T-SERIES 8
T-SERIES
T-SERIES
T-SERIES
T-SERIES
T-SERIES 9
T-SERIES
TC
EC
GC
TC
OWNER
EC
TC
GC
TC
EC
EC
EC
EC OR TC
TC
EC
EC
TC
TC
TC
TC
TC
EC
GC
EC
EC
TC
EC
GC
TC
OWNER
EC
TC
GC / EC / TC
TC
TV SERVICE, DISTRIBUTION EQUIPMENT AND RECEIVERS N/A OWNER OWNER
TECHNOLOGY SYSTEMS RESPONSIBILITY MATRIX NOTES:
1. UNDERGROUND CONDUITS IN/OUT OF BUILDING ARE SHOWN FOR INTENT ONLY. ACTUAL LOCATIONS SHALL BE COORDINATED IN THE FIELD WITH OTHER UNDERGROUND WORK (STORM, SEWER, POWER, ETC).
2. FLOOR BOX LOCATIONS SHALL BE COORDINATED WITH THE LOCATION(S) OF ASSOCIATED MILLWORK AND FURNITURE.
3. PENETRATIONS THROUGH FLOORS AND FIRE-RATED WALLS WHERE APPLICABLE SHALL BE FIRESTOPPED IN A MANNER THAT MAINTAINS THE RATING OF THE FLOOR OR WALL
PENETRATED. REFER TO ARCHITECTURAL SPECIFICATIONS.
4. CABLE TRAY INDICATED ON DRAWINGS IS SHOWN FOR INTENT, AND THE INSTALLATION OF THE CABLE TRAY SHALL BE COORDINATED WITH OTHER TRADES (MECHANICAL, PLUMBING).
5. LOCATIONS OF TECHNOLOGY SYSTEMS ROUGH-IN SHALL BE COORDINATED WITH ASSOCIATED POWER RECEPTACLES.
6. PLYWOOD WALL COVERINGS SHALL BE AS SPECIFIED IN ARCHITECTURAL SPECIFICATIONS.
7. ROOF PENETRATIONS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SHALL BE SEALED AS SPECIFIED IN ARCHITECTURAL SPECIFICATIONS.
8. BLOCKING FOR ALL TV AND IDS (FPD) LOCATIONS SHALL BE AS SPECIFIED IN ARCHITECTURAL SPECIFICATIONS OR AS INDICATED ON ARCHITECTURAL DRAWINGS.
9. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL ACCESS CONTROL SYSTEM COMPONENTS WITH DOOR AND DOOR HARDWARE VENDOR.
10. ALL DEVICES TO BE INSTALLED IN LOCATIONS APPROVED BY AUTHORITY HAVING JURISDICTION (AHJ).
GENERAL SYMBOLS
KEYED NOTE, USED TO DESCRIBE ADDITIONAL
INFORMATION OF WORK REQUIRED, SPECIFIC TO
THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
DETAIL NUMBER / SHEET NUMBER#/T-###
9.###
CEILING MOUNTED SPEAKER
VOLUME CONTROL
TELEVISION DISPLAY
AUDIO VISUAL SYMBOLS
PENDANT MOUNTED SPEAKER
S
TV
PAGING HORNS
SCHEDULE NOTES:
REFER TO DIVISION 27 SPECIFICATIONS FOR FACEPLATE, JACK, AND CABLE REQUIREMENTS.
REFER TO DIVISION 26 SPECIFICATIONS FOR RACEWAY AND BOX REQUIREMENTS.
CONNECTOR OPENINGS IN FACEPLATE TO BE DEVICE COUNT-SPECIFIC (E.G. NO BLANKS).
1.
2.
3.
TELECOMMUNICATIONS OUTLET SCHEDULE
SYMBOL COMMENTSDESCRIPTION
1-PORT TELECOMMUNICATIONS OUTLET:
- (1) 3/4" CONDUIT STUB
- (1) 4" SQUARE x 1 1/2" DEEP BACKBOX WITH SINGLE GANG VERTICAL TRIM RING
- (1) SINGLE GANG, SINGLE-PORT FACEPLATE WITH CATEGORY 6 JACK
- (1) CATEGORY 6 CABLE
1-PORT TELECOMMUNICATIONS OUTLET FOR WALL PHONE:
- (1) 3/4" CONDUIT STUB
- (1) 4" SQUARE x 1 1/2" DEEP BACKBOX WITH SINGLE GANG VERTICAL TRIM RING
- (1) STAINLESS STEEL FACEPLATE WITH CATEGORY 6 JACK AND PHONE LUGS
- (1) CATEGORY 6 CABLE
2-PORT TELECOMMUNICATIONS OUTLET:
- (1) 1" CONDUIT STUB
- (1) 4 11/16" SQUARE x 2 1/8" DEEP BACKBOX WITH SINGLE VERTICAL GANG TRIM RING
- (1) SINGLE GANG, TWO-PORT FACEPLATE WITH CATEGORY 6 JACKS
- (2) CATEGORY 6 CABLES
2-PORT TELECOMMUNICATIONS OUTLET FOR WIRELESS ACCESS POINT:
- (1) 1" CONDUIT STUB
- (1) 4 11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- OR -
- (1) TWO-PORT SURFACE HOUSING
- (2) CATEGORY 6A JACKS
- (2) CATEGORY 6A CABLES
4-PORT TELECOMMUNICATIONS OUTLET:
- (1) 1" CONDUIT STUB
- (1) 4 11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG VERTICAL TRIM RING
- (1) SINGLE GANG, FOUR-PORT FACEPLATE WITH CATEGORY 6 JACKS
- (4) CATEGORY 6 CABLES
BOX OR HOUSING
AS NECESSARY TO
MEET
INSTALLATION
CONDITIONS
2-PORT TELECOMMUNICATIONS OUTLET FOR TELEVISION:
- (1) 1" CONDUIT STUB
- (1) 4 11/16" SQUARE x 2-1/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING
- (1) TWO-PORT ANGLED FACEPLATE
- (1) CATEGORY 6 JACK
- (1) F-F BULKHEAD CONNECTOR
- (1) CATEGORY 6 CABLE
- (1) RG-6 CABLE
MOUNT ON CENTER
AT 46" A.F.F.
UNLESS NOTED
OTHERWISE.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :5
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-001
NOTES, SYMBOLS &
ABBREVIATIONS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
TECHSYS ABBREVIATIONS
& AND
3R NEMA 3R RATED
4X NEMA 4X RATED
@ AT
A/E ARCHITECT / ENGINEER
ACS ACCESS CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISH GRADE
ALT ALTERNACE
ANT ANTENNA
AP (WIRELESS) ACCESS POINT
AV AUDIO VISUAL
BET BUILDING ENTRANCE TERMINAL
BLDG BUILDING
C CONDUIT
CAB CABINET
CATV COMMUNITY ANTENNA TELEVISION
CL CENTERLINE
CLG CEILING
COAX COAXIAL
COMM COMMUNICATIONS
DO DOOR OPERATOR
DSS DIGITAL SATELLITE SERVICE
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EMT ELECTRICAL METALLIC TUBING
ETR EXISTING TO REMAIN
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FO FIBER OPTIC
FPD FLAT-PANEL DISPLAY
GC GENERAL CONTRACTOR
GND GROUND
GRC GALVINIZED RIGID CONDUIT
GRS GALVANIZED RIGID STEEL
HH HAND HOLE
HPC HIGH PAIR COUNT
HVAC HEATING, VENTILATION, AIR CONDITIONING
IDF INTERMEDIATE DISTRIBUTION FRAME
IDS INFORMATION DISPLAY SYSTEM
x DENOTES SUBSYSTEM (F, B, T, G)
IDS INTRUSION DETECTION SYSTEM
IMC INTERMEDIATE METALLIC CONDUIT
IT INFORMATION TECHNOLOGY
ITS INFORMATION TRANSPORT SYSTEMS
JB JUNCTION BOX
MAX MAXIMUM
MDF MAIN DISTRIBUTION FRAME
MH MAN HOLE
MIN MINIMUM
MMFO MULTIMODE FIBER OPTIC
MNS MASS NOTIFICATION SYSTEM
MON MONITOR
MTD MOUNTED
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NTWK NETWORK (DATA)
OC ON CENTER
PA PUBLIC ADDRESS
PIR PASSIVE INFRARED
PROJ PROJECTOR
PTZ PAN - TILT - ZOOM
PVC POLYVINYL CHLORIDE
RCV RECEIVER
REQ'D REQUIRED
SCHED SCHEDULE
SE SERVICE ENTRANCE
SMFO SINGLEMODE FIBER OPTIC
SS STAINLESS STEEL
SYS SYSTEM
TBR TO BE REMOVED
TC TECHNOLOGY CONTRACTOR
TGB TELECOMMUNICATIONS GROUNDING BUSBAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
TO TELECOMMUNICATIONS OUTLET
TSE TELEPHONE SERVICE EQUIPMENT
TV TELEVISION
TYP TYPICAL
UF UNDER FLOOR
UG UNDERGOUND
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED TWISTED PAIR
VSS VIDEO SURVEILLANCE SYSTEM
WL WET LOCATION LISTED
WP WEATHERPROOF
WS WORKSTATION
10/04/19 REVISED BID
DOCUMENTS
FFE: 4,089.17
T
T
CB
1-4"CM
H
-7
TAXIWAY F
T A
X
IW
A Y
G
T A
X
IW
A Y
D
BONG STREET
V A
N D
E N
B E
R G
D R
IV
E
130 216
T-011
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :5
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-010
TECHNOLOGY
SYSTEMS SITE PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
10/04/19 REVISED BID
DOCUMENTS
1" = 100'-0"1
TECHNOLOGY SYSTEMS SITE PLAN
FFE: 4,089.17
CB
9.501 9.604
9.611
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :5
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-011
TECHNOLOGY
SYSTEMS
ENLARGED SITE
PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
10/04/19 REVISED BID
DOCUMENTS
KEYED NOTES
9.501 EXISTING CONDUIT TO BE REMOVED. CABLE TO BE PULLED BACK AND
EXTENDED BACK TO BUILDING 500 USING NEW CONDUIT PATHWAY
INSTALLED AS PART OF THIS PROJECT. IF UNABLE TO UTILIZE EXISTING
CABLE, A NEW CABLE SHALL BE INSTALLED TO REPLACE EXISTING CABLE.
REFER TO SITE UTILITY PLANS FOR ADDITIONAL DETAILS.
9.604 PROVIDE (4) 4" CONDUITS. REFER TO UTILITY AND TECHNOLOGY SITE
DRAWINGS FOR ADDITIONAL DETAILS. REFER TO SPECIFICATION SECTION
07 84 00 FOR FIRESTOPPING INFORMATION. COORDINATE ENTRY WITH
CHASE, STRUCTURAL COMPONENTS, AND TECHNOLOGY ROOM.
9.611 PROVIDE (6) 4" UG CONDUITS. REFER TO CIVIL DRAWINGS FOR ADDITIONAL
INFORMATION.
1" = 20'-0"1
TECHNOLOGY SYSTEMS ENLARGED SITE PLAN
UP
12"x2"
9'-0" AFF
12"x2"
10'-0" AFF
12"x2"
8'-6" AFF
(2) 4" CONDUITS
9.604
9.607
1'-0" 8"
(3) 4" CONDUITS
(2) 4" CONDUITS
8"
12"x2"
8'-6" AFF
HANGAR
X-RAY VAULT
ROOM
X-RAY CR
FILM VIEWING
ROOM
OIL ANALYSIS
ROOM
OFFICE
EQUIPMENT
ROOM
VEST.
STENCIL
ROOM
FIRE
PROTECTION
ROOM
AIR LOCK
PPE CLEAN
ROOM/
CIRCULAT.
WOMEN'S
LOCKER
ROOM
WOMEN'S
JAN
MEN'S
LAUNDRY
ROOM
MEN'S
LOCKER
ROOM
HALLWAY
VEST.
OFFICE
TRAINING /
BREAK ROOM
PAINT BOOTH
BEAD BOOTH
ROOM
PAINT MIXING
ROOM/STOR
INSPECTION
BAY
T-401
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :5
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-100
FIRST FLOOR
PATHWAYS PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
1/8" = 1'-0"1
FIRST FLOOR PATHWAYS PLAN
10/04/19 REVISED BID
DOCUMENTS
KEYED NOTES
9.604 PROVIDE (4) 4" CONDUITS. REFER TO UTILITY AND TECHNOLOGY SITE
DRAWINGS FOR ADDITIONAL DETAILS. REFER TO SPECIFICATION SECTION
07 84 00 FOR FIRESTOPPING INFORMATION. COORDINATE ENTRY WITH
CHASE, STRUCTURAL COMPONENTS, AND TECHNOLOGY ROOM.
9.607 PROVIDE (4) 4" CONDUITS THROUGH FLOOR FROM IT 203 TO CABLE TRAY
ABOVE FIRST FLOOR CEILING. REFER TO SPECIFICATION SECTION 07 84 00
FOR FIRESTOPPING INFORMATION.
W
W
W
W
W
W
W
W
W
W
W W
W
W
AP
AP
APAPAP
APAP
W
W
W
W
TV
AP
AP
X-RAY VAULT
ROOM
X-RAY CR
FILM VIEWING
ROOM
OIL ANALYSIS
ROOM
OFFICE
EQUIPMENT
ROOM
VEST.
STENCIL
ROOM
FIRE
PROTECTION
ROOM
AIR LOCK
PPE CLEAN
ROOM/
CIRCULAT.
WOMEN'S
LOCKER
ROOM
WOMEN'S
JAN
MEN'S
LAUNDRY
ROOM
MEN'S
LOCKER
ROOM
HALLWAY
VEST.
OFFICE
TRAINING /
BREAK ROOM
PAINT BOOTH
BEAD BOOTH
ROOM
PAINT MIXING
ROOM/STOR
HANGAR
9.609
9.610
72" AFF
46" AFF
46" AFF
46" AFF46" AFF
46" AFF
46" AFF
46" AFF
INSPECTION
BAY
9.702
T-401
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :0
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-101
FIRST FLOOR
COMMUNICATIONS
PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
KEYED NOTES
9.609 XRAY VAULT ROOM RECESSED BACKBOXES TO BE LINED WITH EQUAL
THICKNESS SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE
DONE SO WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY
THROUGH THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL
BE COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
9.610 HANGAR RECESSED BACKBOXES TO BE LINED WITH EQUAL THICKNESS
SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE DONE SO
WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY THROUGH
THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL BE
COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
9.702 COORDINATE MOUNTING HEIGHT OF TELECOMMUNICATIONS OUTLET WITH
ELECTRICAL RECEPTACLE.
1/8" = 1'-0"1
FIRST FLOOR COMMUNICATIONS PLAN
DN
W
C
AP
AP
EQUIPMENT
ROOM
IT
ELEC.
T-401
T-401
T-4015
ACS-2
ACS-1
203A
201A
T-401
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :0
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-102
EQUIPMENT SPACE
TECHNOLOGY
SYSTEMS PLANS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
1/8" = 1'-0"1
EQUIPMENT SPACE TECHNOLOGY SYSTEMS PLAN
KEYED NOTES
ACS-1 EXTERIOR ACCESS CONTROLLED SINGLE DOOR. REFER TO 1/T-502.
ACS-2 EXTERIOR ACCESS CONTROLLED DOUBLE DOOR. REFER TO 2/T-502.
M
M
M
M
IDS
IDS
IDS
IDS
ID
S
IDS
IDS
S L
C
C
C
C
C
C
X-RAY VAULT
ROOM
X-RAY CR
FILM VIEWING
ROOM
OIL ANALYSIS
ROOM
OFFICE
EQUIPMENT
ROOM
STENCIL
ROOM
FIRE
PROTECTION
ROOM
PPE CLEAN
ROOM/
CIRCULAT.
WOMEN'S
LOCKER
ROOM
WOMEN'S
JAN
LAUNDRY
ROOM
OFFICE
TRAINING /
BREAK ROOM
PAINT BOOTH
BEAD BOOTH
ROOM
PAINT MIXING
ROOM/STOR
VEST.
AIR LOCK
MEN'S
MEN'S
LOCKER
ROOM
HALLWAY
VEST.
104A
101A
123A
123C
111A
104B
105A
107A
108A
109A110A
103B
116A
114A
111B
112A
113A
117A
120A
118A
115A
120B
124B
101B
121A
125A
126A
ACS-2
ACS-1
ACS-3
ACS-3
ACS-1
116B
125C
B
CAM-04
F - 270°
15'-0" AFG
ACS-3
108B
103A
122A
113B
ACS-1
PIR
PIR
PIR
PIR
9.609
9.610
CAM-05
F - 90°
15'-0" AFF
CAM-06
F - 90°
15'-0" AFF
CAM-03
F - 270°
12'-6" AFG
CAM-02
F - 270°
12'-6" AFG
CAM-01
F - 270°
12'-6" AFG
HANGAR
INSPECTION
BAY
SECURITY GENERAL NOTES:
1. ALL SECURITY CABLING SHALL BE INSTALLED IN 1" ENCLOSED CONDUIT AND
HOME RUN BACK TO IT ROOM 203.
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :0
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-121
FIRST FLOOR
SECURITY PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
KEYED NOTES
9.609 XRAY VAULT ROOM RECESSED BACKBOXES TO BE LINED WITH EQUAL
THICKNESS SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE
DONE SO WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY
THROUGH THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL
BE COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
9.610 HANGAR RECESSED BACKBOXES TO BE LINED WITH EQUAL THICKNESS
SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE DONE SO
WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY THROUGH
THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL BE
COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
ACS-1 EXTERIOR ACCESS CONTROLLED SINGLE DOOR. REFER TO 1/T-502.
ACS-2 EXTERIOR ACCESS CONTROLLED DOUBLE DOOR. REFER TO 2/T-502.
ACS-3 EXTERIOR ACCESS CONTROLLED SINGLE DOOR. REFER TO 3/T-502.
1/8" = 1'-0"1
FIRST FLOOR SECURITY PLAN
S S
S S
S S
S
S
S
SS
S
S
S
S
S
S
SSS
S
S
S
S S
S S
SSS
S
S
S
S
S
S
S
S
TV
SSSS
SSSS
AUDIO VISUAL GENERAL NOTES:
1. ALL PAGING CABLING SHALL BE RUN BACK TO IT ROOM 203. REFER TO
SPECIFICATIONS AND MANUFACTURERS RECOMMENDATION FOR CABLE SIZE
AND QUANTITY OF SPEAKERS ALLOWABLE PER CABLE RUN.
X-RAY VAULT
ROOM
X-RAY CR
FILM VIEWING
ROOM
OIL ANALYSIS
ROOM
OFFICE
EQUIPMENT
ROOM
INSPECTION
BAY
STENCIL
ROOM
FIRE
PROTECTION
ROOM
PPE CLEAN
ROOM/
CIRCULAT.
WOMEN'S
LOCKER
ROOM
WOMEN'S
JAN
LAUNDRY
ROOM
OFFICE
TRAINING /
BREAK ROOM
PAINT BOOTH
BEAD BOOTH
ROOM
PAINT MIXING
ROOM/STOR
VEST.
AIR LOCK
MEN'S
MEN'S
LOCKER
ROOM
HALLWAY
VEST.
9.609
9.610
HANGAR
9.901
9.901 9.901
9.901
9.902
(TYP.)
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :0
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-141
FIRST FLOOR AUDIO
VISUAL PLAN
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
KEYED NOTES
9.609 XRAY VAULT ROOM RECESSED BACKBOXES TO BE LINED WITH EQUAL
THICKNESS SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE
DONE SO WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY
THROUGH THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL
BE COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
9.610 HANGAR RECESSED BACKBOXES TO BE LINED WITH EQUAL THICKNESS
SHEET LEAD. CONDUITS PENETRATING LEAD LINING SHOULD BE DONE SO
WITH A LEAD WRAPPED ELBOW TO PREVENT PASSAGE OF X-RAY THROUGH
THE OPENING. ANY PENETRATION INTO LEAD LINED WALL SHALL BE
COVERED BY LEAD TAPE. REFER TO ARCHITECTURAL DRAWINGS FOR
ADDITIONAL DETAILS.
9.901 SPEAKER CABLES IN INSPECTION BAY 103, HANGAR 123, PAINT BOOTH 125,
AND BEAD BOOTH ROOM 127 SHALL BE INSTALLED IN ENCLOSED CONDUIT
BACK TO ACCESSIBLE CEILING SPACE.
9.902 PAGING HORN SHALL BE MOUNTED TO BOTTOM OF CEILING STRUCTURE.
TYPICAL FOR ALL PAGING HORNS IN HANGAR BAY.
1/8" = 1'-0"1
FIRST FLOOR AUDIO VISUAL PLAN
G
B
ACP BET
9.605
9.603
9.602
9.601
9.608 9.608
9.602
9.604
9.605 9.608
ACP
9.701
9.8019.801
9.608
12"x4"
7'-6" AFF
12"x4"
7'-6" AFF
ELECTRICAL CONDUITS
SHOWN FOR REFERENCE
ONLY9.604
9.608
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :1
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-401
ENLARGED PLANS,
ELEVATIONS &
SECTIONS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
KEYED NOTES
9.601 PROVIDE TELECOMMUNICATIONS MAIN GROUND BUS BAR CENTERED AT
6'-0" AFF.
9.602 PROVIDE 12" X 4" CABLE RUNWAY 6" ABOVE TOP OF EQUIPMENT RACKS.
9.603 PROVIDE (2) TWO-POST RACKS WITH VERTICAL WIRE MANAGEMENT.
9.604 PROVIDE (4) 4" CONDUITS. REFER TO UTILITY AND TECHNOLOGY SITE
DRAWINGS FOR ADDITIONAL DETAILS. REFER TO SPECIFICATION SECTION
07 84 00 FOR FIRESTOPPING INFORMATION. COORDINATE ENTRY WITH
CHASE, STRUCTURAL COMPONENTS, AND TECHNOLOGY ROOM.
9.605 PROVIDE 8' X 4' PLYWOOD BACKBOARD ON ALL 4 WALLS. REFER TO
ARCHITECTURAL SPECIFICATIONS.
9.608 PROVIDE 12" X 4" CABLE RUNWAY.
9.701 PROVIDE BUILDING ENTRANCE TERMINAL.
9.801 PROVIDE ACCESS CONTROL PANEL (ACP) AND ASSOCIATED POWER
SUPPLY.
1/4" = 1'-0"1
IT 203 - EAST WALL
1/4" = 1'-0"2
IT 203 - NORTH WALL
1/4" = 1'-0"4
IT 203 - SOUTH WALL
1/4" = 1'-0"5
IT 203 - WEST WALL
1/4" = 1'-0"3
ENLARGED PLAN - IT 203
1/4" = 1'-0"6
CABLE RUNWAY PLAN - IT 203
10/04/19 REVISED BID
DOCUMENTS
1/4" = 1'-0"7
CONDUIT ENTRY CHASE
SECURE MOUNTING PLATE TO
EQUIPMENT RACK PER
MANUFACTURERS RECOMMENDATIONS.
EQUIPMENT RTACK NOT SHOWN.
CABLE
RUNWAY
CABLE RUNWAY
ELEVATION KIT
(TYPICAL)
NOTES:
REFER TO SECTIONS 27 05 28
PROPER ORIENTATION OF CABLE RUNWAY
POSITIONS CROSS MEMBERS (SLATS) AT TOP OF
STRINGERS.
TRAPEZE SUPPORT
CABLE TRAY DETAIL GENERAL NOTES:
SEE PLAN DRAWINGS FOR WIDTH(S) AND DEPTH(S).
ANCHOR THREADED ROD TO STEEL WITH BEAM CLAMPS OR USING
STEEL DROP-IN ANCHORS. PLASTIC OR LEAD TYPE ANCHORS ARE NOT
APPROVED.
COORDINATE WITH OTHER TRADES TO MAINTAIN CLEARANCE OF ONE
(1) FOOT ON BOTH SIDES OF THE TRAY AND EIGHT (8) INCHES ABOVE
TOP OF THE TRAY.
PROVIDE ALL ANGLES, TEE'S, CROSSES, SPLICES, ACCESSORIES, ETC.
AS REQUIRED.
PROVIDE OFFSETS AS REQUIRED TO CHANGE ELEVATIONS AS
OBSTRUCTIONS DICTATE. WHERE CABLE TRAY CONTINUITY CANNOT
BE MAINTAINED, PROVIDE STRAP BONDED TO ADJACENT TRAY
SECTIONS.
MAINTAIN MINIMUM SEPARATION DISTANCES FROM <480V POWER
LINES AS FOLLOWS:
12" FROM POWER LINES OF <5-KVA
18" FROM HIGH VOLTAGE LIGHTING (INCL. FLUORESCENT)
39" FROM POWER LINES OF 5-KVA OR GREATER
39" FROM TRANSFORMERS AND MOTORS.
PROVIDE RADIUSED DROP-OUT AT LOCATIONS WHERE CABLE EXITS
THE TRAY.
THREADED ROD
3/8" ATRPLASTIC SLEEVE
(~6-INCH LENGTH)
STRUT OR
MANUFACTURER-
SUPPLIED HANGER
WALL BRACKET
MANUFACTURER-
SUPPLIED WALL
BRACKET
NEW FLUSH MOUNTED
TELECOM OUTLET.
PROVIDE BACKBOX IN WALL.
STUD WALL
1" EMT CONDUIT;
LAY-IN GYP, PLASTER
OR TILE CEILING
DECK OR CONCRETE STRUCTURE
TERMINATE CONDUIT WITHIN
12" OF CABLE TRAY
CORRIDOR FLOOR
CABLE TRAY IN CORRIDOR
SUPPORT 1" CONDUIT
PER CODE.
DETAIL NOTES:
THIS METHOD OF INSTALLATION REQUIRED
IN AREAS WITH INACCESSIBLE CEILING.
REFER TO ELECTRICAL DRAWINGS AND
SPECIFICATIONS FOR CONDUIT
INSTALLATION DETAILS.
1.
2.
3" MAX
DETAIL NOTES:
MINIMUM SIZING OF SLEEVE FOR
HORIZONTAL (STATION) CABLING:
* 1" EMT CONDUIT (1-6 CABLES)
* 1.5" EMT CONDUIT (15 CABLES OR LESS)
* 2" EMT CONDUIT (20 CABLES OR LESS)
* 3" EMT CONDUIT (MORE THAN 15 CABLES;
NOT TO EXCEED 40% FILL)
WHERE SLEEVE IS PART OF BACKBONE
CABLE PATH, SIZE TO RESULT IN MAXIMUM
OF 40% FILL (CABLE AREA / SLEEVE AREA).
REFER TO 07 84 00 FOR ADDITIONAL
FIRESTOP INFORMATION.
CONDUIT BUSHING,
TYPICAL
CONDUIT SLEEVE
BUILDING WALL. SEE
ARCHITECTURAL
DRAWINGS FOR WALL
CONSTRUCTION TYPES.
FIRE SEAL LOCATION
(TYPICAL)
FIRE SEAL INSIDE
SLEEVE(S) PER CODE.
FIRE STOP FOLLOWING
CABLE INSTALLATION.
FIRE SEAL VACANT,
SPARE SLEEVES AS
1.
2.
3.
INSULATING
STANDOFF
20"x4"x1/4" COPPER PLATE.
DRILLED PER ANSI/TIA J-STD-607-A
TWO-HOLE COPPER
COMPRESSION-TYPE LUG
BOLTED TO TMGB (TYP)
BONDING JUMPERS TO
TELECOMMUNICATIONS
EQUIPMENT (BY DIV. 27)
BONDING CONDUCTOR FOR
TELECOMMUNICATIONS TO
ELECTRICAL SERVICE
ENTRANCE
TELECOMMUNICATIONS BONDING BACKBONE
(IF APPLICABLE)
DETAIL NOTES:
REFER TO SPECIFICATION SECTION 26 20 00 FOR ADDITIONAL
DETAILS.
1.
CONFIGURATION:
WALL-MOUNT TELEPHONE
MODULAR JACK - DATA
SYMBOL
REFER TO SPECIFICATION
SECTION 27 00 00 FOR FACEPLATE
MATERIAL & COLOR (TYP).
APPLY LABEL TO FACEPLATE;
LAMINATE
MOUNTING LUG
(1 OF 2)
W
I.D. LABEL
(LAMINATED)
BLANK INSERTS AS
REQUIRED; ALL UNUSED
POSITIONS (TYP).
DETAIL NOTES:
SEE SPECIFICATION SECTION 27 00 00 - COMMUNICATIONS
CABLE AND EQUIPMENT - FOR PERFORMANCE, PIN/PAIR
ASSIGNMENTS AND COLOR..
CONNECTOR OPENINGS IN FACEPLATE TO BE DEVICE COUNT-
SPECIFIC (E.G. NO BLANKS).
KEY:
MODULAR JACK - VOICE
BLANK INSERT
1.
2.
CONFIGURATION:
4-PORT
SYMBOL
WORKAREA FLOOR
DECK OR CONCRETE STRUCTURE
SUPPORT CONDUIT PER CODE.
NEW SURFACE MOUNTED TELECOM
OUTLET. PROVIDE SURFACE BOX.
CONCRETE OR
CONCRETE BLOCK WALL
STRAP AS REQUIRED.
SURFACE-MOUNTED EMT CONDUIT
LAY-IN, GYP, PLASTER, OR TILE
CEILING
CORRIDOR FLOOR
CABLE TRAY IN
CORRIDOR
DETAIL NOTES:
REFER TO ELECTRICAL DRAWINGS AND
SPECIFICATIONS FOR CONDUIT
INSTALLATION DETAILS.
1.
TERMINATE CONDUIT WITHIN
12" OF CABLE TRAY
1" CONDUIT TO CABLE TRAY.
SECURE TO STRUCTURE.
WIRELESS ACCESS POINT
STRUCTURAL
COMPONENTS
COMMUNICATIONS CABLE(S) BY DIVISION 27
4-11/16" DEEP OUTLET BOX WITH 1-GANG
COVER (MUD RING) AND BLANK COVER
PLATE BY DIVISION 26
SUSPENDED CEILING
BOX SUPPORT HANGER BY DIVISION 26
PATCH CORD(S) BY OWNER
FUTURE OWNER PROVIDED
WIRELESS ACCESS POINT
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :1
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-501
DETAILS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
NO SCALE3
CABLE RUNWAY/RACK
NO SCALE4
CABLE TRAY
NO SCALE1
TO PATHWAY - FLUSH - CONDUIT TRAY
NO SCALE7
WALL PENETRATION SLEEVE
NO SCALE5
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
NO SCALE6
TO LAYOUTS
10/04/19 REVISED BID
DOCUMENTS
NO SCALE2
TO PATHWAY - SURFACE CONDUIT - TRAY
NO SCALE8
WAP - PENDANT MOUNT
NO SCALE9
WAP - CEILING MOUNT
POWER
TRANSFER
HINGE
CARDREADER/PINPAD
SECURE SIDE NON-SECURE SIDE
CABLING TO
DOOR MODULE
IN 3/4"C
LOCKING/REX
HARDWARE
(TYPICAL)
LOCKING/REX
HARDWARE
(TYPICAL)
STATUS
SENSOR
1" CONDUIT TO
ROOM 203
NEMA 1 ENCLOSURE
1" CONDUIT TO
ROOM 203
NEMA 1 ENCLOSURE
CARDREADER/PINPAD
NON-SECURE SIDESECURE SIDE
STATUS
SENSOR
CABLING TO
DOOR MODULE
IN 3/4"C
POWER
TRANSFER
HINGE
LOCKING/REX
HARDWARE
(TYPICAL)
CARDREADER/PINPAD
NON-SECURE SIDESECURE SIDE
STATUS
SENSOR
1" CONDUIT TO
ROOM 203
NEMA 1 ENCLOSURE
POWER
TRANSFER
HINGE
LOCKING/REX
HARDWARE
CABLING TO
DOOR MODULE
IN 3/4"C
LOCKING/REX
HARDWARE
(TYPICAL)
PLAN VIEW
FIRST FLOOR
H E
IG
H
T O
F B
U
IL
D
IN
G
ELEVATION VIEW
C O
N F
IR
M
H E
IG
H
T O
F
C A
M E
R A
W
IT
H O
W N
E R
EXTERIOR WALL
CORNER MOUNT
BRACKET
CAMERA
ENCLOSURE
(PENDANT-MOUNT)
CAMERA
DOME
SECURE USING FASTENERS AND
ANCHORS PER MANUFACTURERS
RECOMMENDATIONS FOR SURFACE
TYPES AND ENVIRONMENT. PROVIDE
MOUNTING BOX IF NEEDED.
1" CONDUIT
TO ROOM 203
FINISHED FLOOR
96"
46"
18"
TECHNOLOGY OUTLETS
LOCATED IN OFFICES AND
OTHER FINISHED AREAS
UNLESS NOTED OTHERWISE.
ALL WALL TELEPHONE
OUTLETS UNLESS
NOTED OTHERWISE.
ALL WALL MOUNTED
CAMERAS UNLESS NOTED
OTHERWISE.
TOP OF CAMERA
MIDDLE OF
OUTLET BOX
42" AFF.
(MIN.)
48" AFF.
(MAX.)
ALL CARD READER DEVICES
UNLESS NOTED OTHERWISE.
60"
ALL DISPLAYS UNLESS
NOTED OTHERWISE.
MIDDLE OF
DISPLAY
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :1
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-502
DETAILS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
NO SCALE2
DOOR - DOUBLE
NO SCALE1
DOOR - SINGLE - LEVER EXIT DEVICE
10/04/19 REVISED BID
DOCUMENTSNO SCALE3
DOOR - SINGLE - RIM EXIT DEVICE
NO SCALE5
EXTERIOR CORNER MOUNT CAMERA
NO SCALE4
DEVICE MOUNTING HEIGHTS DETAIL
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :1
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-601
SCHEDULES
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
10/04/19 REVISED BID
DOCUMENTS
203A 28 SGL IT ROOM MECHANICAL SPACE 201 N IT ROOM 203 DR S LEVER
201A 25 DBL EQUIPMENT SPACE OUTSIDE STAIRWELL N MECHANICAL SPACE 201 DR S LEVER
124B 21 SGL AIR LOCK HANGER N AIR LOCK 124 DR S LEVER INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM
123C 19 SGL SOUTH HANGER DOOR OUTSIDE N HANGER DR S RIM EXIT DEVICE INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM
123A 19 SGL WEST HANGER DOOR OUTSIDE N HANGER DR S RIM EXIT DEVICE INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM
111A 3 SGL NORTH VESTIBULE 111 OUTSIDE N ROOM 111-VESTIBULE DR S RIM EXIT DEVICE INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM
104B 7 SGL X-RAY VAULT ROOM NORTH ROOM 105 X-RAY CR N ROOM 104 X-RAY VAULT ROOM DR S LEVER INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM AND X-RAY INTERLOCK SYSTEM
104A 6 DBL X-RAY VAULT ROOM SOUTH OUTSIDE N ROOM 104 X-RAY VAULT ROOM DR S LEVER INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM AND X-RAY INTERLOCK SYSTEM
101A 1 SGL SOUTH VESTIBULE 101 OUTSIDE N ROOM 101-VESTIBULE DR S LEVER INTEGRATE ACCESS CONTROL WITH INTRUSION DETECTION SYSTEM
DOOR HW SET SGL / DBL DESCRIPTION ROOM DEVICE ROOM DEVICE
FROM TO
DPS REX
DOOR
COMMENTS
ACCESS CONTROLLED DOOR AND ALARM ZONE SCHEDULE
DIV. 08
E L
EL
PT
ML
DL
DR
ADO
DOOR HARDWARE
ELECTRIC STRIKE
ELECTRIFIED LOCKSET
ELECTRIC LATCH
ELECTRIC POWER TRANSFER
MAGNETIC LOCK
DELAYED EGRESS DEVICE
DOOR HARDWARE REX
AUTOMATIC DOOR OPERATOR
DIV. 28
K D M S A Y
ALARM SYSTEM
KEYPAD (ARM / DISARM)
DURESS PUSHBUTTON
MOTION DETECTOR (WINDOWS / DOORS)
DOOR POSITION SWITCH
AUDIBLE/VISUAL ALARM
KEY RESET
DIV. 28
C N S M P
ACCESS CONTROL SYSTEM
CARD READER
CARD READER W/ PIN PAD
DOOR POSITION SWITCH
MOTION DETECTOR - REX
PUSH BUTTON - REX
3 SYMBOLS AND ABBREVIATIONS USED IN THE SCHEDULE INCLUDE THE
FOLLOWING:
2 UNLESS NOTED OTHERWISE, ALL ELECTRIFIED LOCKSETS AND DOOR
HARDWARE REX DEVICES SHALL BE FED VIA ELECTRIC POWER TRANSFER.
1 UNLESS NOTED OTHERWISE, ALL DOOR HARDWARE DEVICES SHALL BE FED
FROM THE FACILITY ACCESS CONTROL SYSTEM.
NOTES
CORROSION
CONTROL
HANGAR
(IT 203)
BUILDING
BUILDING
BUILDING
(VSS)
BUILDING
FIRST FLOOR
24 STRAND
SM FIBER
24 STRAND
SM FIBER
24 STRAND
SM FIBER
100 PAIR
CAT3 CABLE
NOTE:
100 PAIR COPPER SHALL BE TERMINATED ON A BUILDING ENTRANCE TERMINAL
ON BOTH ENDS AND GROUNDED. SEE 33 82 00 FOR ADDITIONAL INFORMATION.
1.
ETHERNET SWITCH
IT ROOM 203
POWER
SUPPLY
IT ROOM 203
120 VAC
24 VAC TO
OUTSIDE
CAMERAS
F F F F F F
EXTERIOR
CAMERAS
HANGAR
CAMERAS
CAT. 6
(TYP)
NOTES:
CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. ALL
SECURITY CABLE SHALL BE INSTALLED IN MINIMUM 1" ENCLOSED CONDUIT.
POWER SUPPLY CABLE SHALL BE AS PER MANUFACTURER'S RECOMMENCATION
FOR LENGTH OF CABLE RUN TO ENSURE PROPER VOLTAGE AT THE CAMERA.
1.
2.
S
PAGING
AMPLIFIER
CABLE TYPE
PER SPECIFICATIONS
S
NOTES:
DIAGRAM IS MEANT TO SHOW INTENT AND NOT EXACT EQUIPMENT PLACEMENT AND CONNECTIVITY.
CABLE TYPES PER MANUFACTURERS RECOMMENDATIONS.
NOT ALL STATIONS SHOWN FOR SIMPLICITY.
POWER
TELEPHONE
INTERFACE
S
CABLE TYPE PER MANUFACTURER
SPECIFICATIONS
TYPICAL SPEAKER
(CEILING)
S
S
S S
S
S
S
S
S
1.
2.
3.
PBX
(BY OWNER)
IT ROOM 203
SHEET NO.:
SHEET CONTENTS
DO NOT SCALE DRAWINGS
ISSUED
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.
Mead & Hunt, Inc.
9600 NE Cascades Parkway, Suite 100 Portland, OR 97220 phone: 503-548-1494 meadhunt.com www.tetratech.com
711 TANK FARM ROAD, SUITE 110
SAN LUIS OBISPO, CA 93401
PHONE: (805) 542-9052 FAX: (805) 542-9254
/3 /2
:0 :1
P
M C
R e v it L o c a l\
-1
.0
-E
-C E
N T
R A
L -2 jr m .r v t
T-701
ONE-LINE DIAGRAMS
O R
A N
G
K in g s le y F ie ld
K la m a th
F a lls
O
R
C O
N S
T R
U C
T C
O R
R O
S
IO
N C
O N
T R
O L H
A N
G A
R
3142200-121252.01
KAS
DP
10/04/19
JRM
10/04/19 REVISED BID
DOCUMENTS
NO SCALE1
BACKBONE ONE-LINE DIAGRAM
NO SCALE3
VSS - ONE-LINE DIAGRAM
NO SCALE2
PA - ONE-LINE DIAGRAM
File details come from the government source that posted it. Updated .