This electrical drawing (Sheet E-123) details the power and lighting plans for parking sheds and a heated parking facility for the Wyoming Air National Guard's Combined Vehicle Maintenance & AGE Facility project. The document includes four specific electrical plans: 1) Electrical Lighting Plan for Parking Shed, 2) Electrical Power Plan for Parking Shed, 3) Electrical Power Plan for Heated Shed, and 4) Electrical Lighting Plan for Heated Shed.

The drawing provides comprehensive technical specifications, including key notes about lighting control systems, emergency lighting requirements, and specialized electrical considerations for hazardous locations. Notable technical details include provisions for time clock and photocell-controlled relays, emergency lighting power supplies, occupancy sensors, and specific electrical requirements for the heated parking shed, which is classified as a Class 1 Division 2 hazardous location requiring specialized electrical device enclosures and conduit installations per NEC Article 501 standards. The document is part of a B3 submission dated 11/22/2024 for solicitation W9133L-16-D-0009, prepared by AECOM Technical Services for the Wyoming Air National Guard project.

View the file

Other files for this federal contract opportunity

Other files attached to Construct VM/AGE Complex, newest first.
File Type Posted
E-121 - FIRST FLOOR POWER PLAN - AREA 1.pdf PDF
E-702 - PANEL SCHEDULES.pdf PDF
E-703 - PANEL SCHEDULES.pdf PDF
VM_AGE RFIs Answered - Version 4.xlsx XLSX spreadsheet
E-701 - PANEL SCHEDULES.pdf PDF
E-101 - GROUNDING PLAN.pdf PDF
08 36 19 - BR.pdf PDF
BASE MAP 24 1TO400.pdf PDF
60554859_WY-ANG_VMAF_S22 - Sheet - S-504.pdf PDF
27 51 16 - BR.pdf PDF
10 14 00.20 - BR.pdf PDF
crouse-hinds-arktite-200a-plugs-receptacles-connectors-catalog-page.pdf PDF
MS27265A.PDF PDF
60554859_WY-ANG_VMAF_S22 - Sheet - S-002.pdf PDF
32 13 13.06.pdf PDF
08 33 23 - BR.pdf PDF
Solicitation Amendment W50S8W25RA0030006 SF 30.pdf PDF
ANG Sustainability Requirements Scoresheet.pdf PDF
20230610_060238.jpg JPG image
Jack Tester Info.PDF PDF
9000 Series.pdf PDF
1994 Asbestos Survey - B21_23_24.pdf PDF
Solicitation Amendment W50S8W25RA0030005 SF 30.pdf PDF
20230610_062744.jpg JPG image
20230610_060152.jpg JPG image
VM_AGE RFIs Answered - Version 2.xlsx XLSX spreadsheet
Solicitation Amendment W50S8W25RA0030004 SF 30.pdf PDF
AECOM Drawings.zip ZIP file
Existing VM_AGE as_builts.zip ZIP file
Communications UFC.zip ZIP file
Fire Spec List.zip ZIP file
Pavement Evaluations.zip ZIP file
Laydown Areas.zip ZIP file
VM_AGE Questions and Answers Version 1.xlsx XLSX spreadsheet
GCFI Equipment.zip ZIP file
Geotechnical Report.zip ZIP file
TEMPLATE - H.02 Progress Schedule AF3064 (23-C-XXXX).pdf PDF
Solicitation Amendment W50S8W25RA0030003 SF 30.pdf PDF
Solicitation Amendment W50S8W25RA0030002 SF 30.pdf PDF
B.07 Pre-proposal Conference Site Visit Slides (25-R-A003).pptx PPTX presentation
Pre-Proposal Conference Attendance Roster.pdf PDF
Solicitation Amendment W50S8W25RA0030001 SF 30.pdf PDF
B.08 Attachment 7 - Entry Authorization Form.pdf PDF
Attachment 1 - SOW- Construct VM_AGE Complex - Aug 22 2024.pdf PDF
B.08 Attachment 7 - Entry Authorization Form.pdf PDF
Solicitation - W50S8W25RA003.pdf PDF
B.08 Attachment 5 - Past Performance Questionnaire.docx DOCX document
B.08 Attachment 8 - Wage Determination.pdf PDF
B.08 Attachment 6 - Schedule B (25-R-A003).pdf PDF
B.08 Attachment 4 - Contractor Hazmat Usage Tracking Instructions.pdf PDF
Show all 50

Construct VM/AGE Complex has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SL

V

T

M M

M

M

J

J

J

S L V

D

S L V

D

S3 S11

SD

SE

P1

P1

WP2

WP2

WP2

WP2

WP2

WP2 WP2

WP2

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1

P1 P1

P1

P1

P1

S4 S5 S6 S7 S8 S9 S10 L- 13

18'AFF

(TYP.)

21.5'AFF

(TYP.)

L- 8

PARKING SHED

PG1 TPG1

S3 S11

SD

SE

G/WP

G/WP

G/WP

S4 S5 S6 S7 S8 S9 S10

G/WP G/WP G/WP G/WP G/WP G/WP G/WP G/WP G/WP

G/WP

G/WP

PG1- 16

PG1- 7 PG1- 12

PG1- 17

PG1- 15

PG1- 14PG1- 13PG1- 11

PG1- 10PG1- 9PG1- 8PG1- 5

PG1- 3

PG1- 1

PARKING SHED

60A/3P

PG2

TPG2

S2S1

SA

G/WP

G/WP

G/WP

G/WP

G/WP

G/WP

IH

7-1

IH

7-2

SB

SC

L

01PG2- 7

PG2- 7

PG2- 7

PG2- 1

PG2- 1

PG2- 1

EF

PG2- 5

PG2- 9

PG2- 3

PG2- 3

G/WP

G/WP

PG2- 8

PG2- 8

SBB

PG2- 10

FSCTLCP-1

PG2- 11

HEATED PARKING

PG2- 13

60A/3P

PG2- 15

PG2- 12,14,16

PG2- 18,20,22

PG2- 17

PG2- 17

PROVIDE 120V/1-PHASE

POWER FOR DOOR

CONTROL. (TYP)

S2S1

L4 L-1

L4-EM

L-1

L4-EM

L-1

L4 L-1

WP2

L-1

WP1-EM

L-1b

WP2

L-1

SB

SC

L- 1

WP1-EM

L-1b

+18'AFF

+18'AFF

+10'AFF

+10'AFF

WP2

L-1

WP2

L-1

+18'AFF

+18'AFF

L-1 X2

L-1 X2

+16'AFF

(TYP.)

HEATED PARKING

AREA 1 AREA 2

PARKING SHED

HEATED

PARKING

A E

C O

M T e c h n ic a l S e rv ic e s

IN

C

T o w n

C o u n tr y R o a d

O ra n g e C

A

.5

.2 w w w .a e c o m

.c o m

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B T

W Y

O M

IN

G

A

IR

N A

T

IO

N A

L G

U A

R D

C O

M B

IN

E

D V

E H

IC

L E

M A

IN

T

E N

A N

C E

A

G E

F A

C

IL

IT

Y

P R

O J

D P

E Z

PLAN

NORTH

KEY PLAN

8' 16' 32'

1/16"=1'-0SCALE:

D A

T E

E-123

E L E

C T

R

IC

A L P

O W

E R

L

IG

H

T

IN

G P

L A

N S

P

A R

K

IN

G S

H E

D S

S C

P P

N S

B S

U B

M

IS

S

IO

N

/2

/2

W L -1

-D

-0

3/32" = 1'-0"1

ELECTRICAL LIGHTING PLAN - PARKING

SHED

3/32" = 1'-0"2

ELECTRICAL POWER PLAN - PARKING

SHED

3/32" = 1'-0"3

ELECTRICAL POWER PLAN - HEATED

SHED

3/32" = 1'-0"4

ELECTRICAL LIGHTING PLAN - HEATED

SHED

KEYNOTES

1 ROUTE CIRCUIT VIA TIMECLOCK

CONTROLLED RELAY. REFER TO LIGHTING

CONTROL MATRIX ON SHEET E-002.

2 ROUTE CIRCUIT VIA TIMECLOCK AND

PHOTOCELL CONTROLLED RELAY. REFER

TO LIGHTING CONTROL MATRIX ON SHEET

E-002.

3 PROVIDE POWER FOR FIRE ALARM PANEL.

REFER TO PANEL PG2 SCHEDULE FOR

MORE INFORMATION.

4 PROVIDE POWER AS REQUIRED FOR ROLL

UP DOOR. VERIFY LOCATION PRIOR TO

ROUGH IN.

A. PROVIDE UNSWITCHED CONSTANT HOT

CONDUCTORS TO ALL EMERGENCY LIGHTING

POWER SUPPLIES IN DESIGNATED FIXTURES.

B. ALL FIXTURE AND SENSOR LOCATIONS ARE

DIAGRAMMATIC ONLY. REFER TO

MANUFACTURERS RECOMMENDATIONS FOR

LOCATION AND INSTALLATION DIRECTION.

C. LIGHTING CONTROL SYSTEM SHALL BE

CONNECTED TO BUILDING AUTOMATION

CONTROL SYSTEM. COORDINATE WITH

MECHANICAL CONTROL CONTRACTOR PRIOR

TO INSTALLATION.

D. PROVIDE FAIL-SAFE TYPE OCCUPANCY

SENSORS WHERE LIGHTING WILL STAY "ON" IN

THE EVENT OF A SENSOR FAILURE.

E. ALL WALL MOUNTED VACANCY AND

OCCUPANCY SENSORS SHALL BE EQUIPPED

WITH MANUAL ON/OFF SWITCH.

F. THE LIGHTING CONTROL SYSTEM SHALL BE

NETWORK BASED.

G. COORDINATE ALL LIGHTING CONTROL DEVICE

LOCATIONS AND QUANTITIES WITH THE

MANUFACTURER AND PROVIDE ALL

COMPONENTS REQUIRED FOR A FULLY

FUNCTIONAL LIGHTING CONTROL SYSTEM.

H. REFER TO LIGHTING CONTROL MATRIX ON

SHEET E-002.

I. DAYLIGHT ZONE SHALL MATCH WINDOW HEAD

HEIGHT. CONTRACTOR SHALL VERIFY WINDOW

HEAD HEIGHT PRIOR TO INSTALLATION OF

PHOTOCELL. PHOTOCONTROL SHALL REDUCE

ELECTRIC LIGHTING IN RESPONSE TO

AVAILABLE DAYLIGHT TO AT LEAST ONE

CONTROL POINT BETWEEN 70% AND 50%

POWER, A SECOND POINT BETWEEN 40% AND

20% POWER, AND A THIRD POINT FULLY OFF.

J. ALL RECEPTACLES SHALL BE LABELED WITH

THE PANEL AND CIRCUIT NUMBER THAT IT IS

FED FROM.

K. FOR ALL SPECIALITY EQUIPMENT, VERIFY

POWER REQUIREMENTS AND EXACT

LOCATIONS PRIOR TO ELECTRICAL DEVICE

ROUGH-IN.

L. HEATED PARKING SHED IS HAZARDOUS

LOCATION CLASSIFIED AS CLASS 1 DIVISION 2.

ALL ELECTRICAL DEVICES IN THIS SPACE SHALL

BE IN C1D2 RATED ENCLOSURE WHERE

REQUIRED BY NEC 501.105(B)(2), 501.115(B)(1),

AND 501.150(B)(1). INSTALLATION SHALL BE IN

ACCORDANCE WITH NEC ARTICLE 501.

M. ALL CONDUITS INSIDE HEATED PARKING SHED

(CLASS 1 DIVISION 2 LOCATION) SHALL BE RIGID

METAL CONDUIT (RMC) OR IMTERMEDIATE

METALLIC CONDUIT (IMC) WITH LISTED

FITTINGS.

N. CONDUIT CONNECTIONS TO DEVICES THAT ARE

REQUIRED TO BE C1D2 RATED SHALL BE

PROVIDED WITH CONDUIT SEALS PER NEC

501.15(B)(1). IN EACH CONDUIT RUN PASSING

FROM A CLASS 1 DIVISION 2 LOCATION INTO AN

UNCLASSIFIED LOCATION, SEAL

FITTINGS SHALL BE PROVIDED ON EITHER SIDE

AND WITHIN 10' OF THE BOUNDARY PER NEC

501.15(B)(2). ALL SEALS SHALL COMPLY WITH

NEC 501.15(C).

GENERAL NOTES:

B S

U B

M

IS

S

IO

N

F

IN

A

L

/2

/2 shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud

File details come from the government source that posted it. Updated .