10 14 00.20 - BR.pdf
PDF 31 KB Posted
- Attached to
- Construct VM/AGE Complex Federal contract opportunity
- Solicitation number
- W50S8W25RA003
- Issued by
- Department of the Army National Guard
About this file
This document is a technical specification section (Section 10 14 00.20) for Interior Signage for a Combined Vehicle Maintenance and AGE Facility project. The specification provides detailed requirements for the design, fabrication, and installation of interior signs, including room identification, directional signage, and exit door tactile signs. Key technical requirements include using decorative laminate panel sign systems with tactile graphics, ADA-compliant lettering raised 1/32 inch, and signs that can accommodate updatable message inserts. The signs must meet various federal standards including ICC/ANSI A117.1 for accessibility, NFPA 101 Life Safety Code, and Americans with Disabilities Act guidelines.
The specification covers extensive technical details such as material specifications (aluminum alloy, plastic laminate), graphics production (machine-engraved), mounting methods (surface mounted with various attachment options), and installation guidelines. Submittal requirements include shop drawings, product data, samples, and operation and maintenance documentation. The contractor must provide extra stock paper inserts, laser print templates, and software for user-produced signs. A 2-year manufacturer's warranty is required, and the signs must be installed in compliance with mounting height and location requirements specified in 36 CFR 1191.
View the file
Other files for this federal contract opportunity
Show all 50
Construct VM/AGE Complex has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100% Revised B3 Submission Combined Vehicle Maintenance and AGE Facility
SECTION 10 14 00.20
INTERIOR SIGNAGE
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ALUMINUM ASSOCIATION (AA)
AA PK-1 (2015) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings & Ingot
AMERICAN WELDING SOCIETY (AWS)
AWS D1.2/D1.2M (2014; Errata 1 2014; Errata 2 2020) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B221 (2021) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM D635 (2018) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
INTERNATIONAL CODE COUNCIL (ICC)
ICC/ANSI A117.1 (2009) Accessible and Usable Buildings and Facilities
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2021 ; TIA 21-1 ) Life Safety Code
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST)
NIST SP 800-82 (2015; Rev 2) Guide to Industrial Control Systems (ICS) Security
SECTION 10 14 00.20 Page 1
BID QUESTION REVISIONS
U.S. DEPARTMENT OF DEFENSE (DOD)
DOD 8510.01 ( 2022 ) Risk Management Framework (RMF) for DoD Information Technology (IT)
DODI 8500.01 (2014) Cybersecurity
UFC 4-010-06 (2016; with Change 1, 2017) Cybersecurity of Facility-Related Control Systems
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval.for information only. W Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Detail Drawings ; G
SD-03 Product Data
Room Identification And Directional Signage System ; G
Exit Door Tactile Sign ; G
Building Directories ; G
SD-04 Samples
Interior Signage ; G
Software ; G
Room Identification And Directional Signage System ; G
Exit Door Tactile Sign ; G
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions ; G
Protection and Cleaning ; G
1.3 EXTRA MATERIALS
Provide extra stock paper inserts and laser print templates to support end-user printing copy and one copy of the software for user produced signs and inserts after project completion and equipment necessary for removal of signage parts and pieces.
SECTION 10 14 00.20 Page 2
1.4 QUALITY ASSURANCE
1.4.1 Samples
Submit interior signage samples of each of the following sign types showing typical quality, workmanship and color: all sign types included in project . Approved samples may be installed in the work, provided each sample is identified and location recorded.
1.4.2 Detail Drawings
Submit detail drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, mounting height, shape and thickness of materials, and details of construction. Include a schedule showing the location, each sign type, and message.
1.4.3 Sign Fabricator
Sign Fabricator to follow room number strategies created by designer. The room numbering system to be reviewed and approved by the Contracting Officer and command end users during the shop drawing phase, and prior to fabrication.
1.4.4 Cybersecurity
a. The Risk Management Framework (RMF) is the process by which information systems are accredited for operation by a designated official from the Using Military Department. It is the standard process under which all DoD information systems achieve and maintain their Authority To Operate. The cybersecurity process is documented in DOD 8510.01 and NIST SP 800-82 . Refer to UFC 4-010-06 and DODI 8500.01 for additional requirements.
b. All systems that are IP addressable or interface with the Assured Network required certification to operate. Coordinate with the Government to initiate and complete the accreditation process.
c. Cybersecurity requires input from the system vendor or provider and support from the local IMD. The local IMD-IA office is the point of contact for all Cyber Security requirements. The local CMIO is the point of contact for all clinical and functional system requirements.
1.5 DELIVERY, STORAGE, AND HANDLING
Package materials to prevent damage and deterioration during shipment, handling, storage and installation. Deliver products to the jobsite in manufacturer's original packaging and store in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective interior signage materials and workmanship for a period of 2 years from date of final acceptance of the work.
SECTION 10 14 00.20 Page 3
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM
Provide signs, plaques, directories, and dimensional building letters that are standard products of manufacturers regularly engaged in the manufacture of such products that essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening. Obtain signage from a single manufacturer with edges and corners of finished letter forms and graphics true and clean.
2.1.1 Panel Sign Systems
Provide decorative laminate face with applied tactile graphics, sign is fabricated of a balanced core sandwiched between 0.035 inch standard grade high pressure laminated faces. Provide signs that can accept printable message inserts. Provide paper or acetate inserts with a 0.080 inch thick non glare acrylic window to allow sign to be updated.
2.1.2 Standard Room Signs
Provide signs that include tactile letters, symbols and Braille for interior rooms or spaces where the sign is not likely to change over time. Tactile text descriptions are required for pictograms that are provided to identify a permanent room. Examples include interior signs that label restrooms, stairs, room numbers or letters, and room names.
These permanent room signs can include paper inserts for updatable information.
2.1.2.1 Tactile Letters, Symbols and Braille
Provide ADA compliant material per 36 CFR 1191 which is raised 1/32 inch from the first surface, has a minimum 5/8 inch in height and is an ADA acceptable font. The color of the tactile letters is required to contrast with the sign face color per ADA standards. The ADA required Braille has a minimum durometer reading of 90. All raised letters, numbers and symbols are to comply.
2.1.3 Message Inserts
Provide updatable message inserts covered with a clear matte 0.015 inch vinyl protective overlay. The insert is typeset message laser printed on paper card stock . Provide paper and software with message template for creating text and symbols for computers identified for Government production of paper inserts after project completion. Manufacturer is required to offer online ordering capabilities to facilitate and expedite ordering packages of replacement, color-coated paper inserts. Furnish one device to assist in removing face sheet.Provide sliding inserts that slide horizontally exposing different graphic information as identified on the drawings.
2.1.4 Type of Mounting for Signs
Provide surface mounted signs . . Mount framed plaques with manufacturer's standard (1/6 inch) 1.59 mm thick closed cell vinyl foam with adhesive backing. Adhesive must be transparent, long aging, high tech formulation on two sides of the vinyl foam. Double-faced tape consisting of acrylic adhesive on polyurethane foam used in conjunction with silicone adhesive .
Provide signs with aluminum ceiling/projecting mount attachment extrusion
SECTION 10 14 00.20 Page 4 to secure to ceiling or wall surface, along with matting ceiling/projecting mount track extrusion for hanging, projecting, and double-sided signs. Provide mounting for ceiling/projecting mount attachment extrusion by mechanical fasteners, selected based on wall or ceiling conditions. Mount track extrusion hinges over width of mount attachment and secured with 3.5 by 0.06 mm (6-32 inch) by 6 mm (1/4 inch) cone point stainless steel set screws.
2.1.5 Character Proportions and Heights
Letters and numbers on signs conform to 36 CFR 1191 .
2.2 EXIT DOOR TACTILE SIGN
Provide tactile sign with the message EXIT at each exit door that requires an exit sign to conform with NFPA 101 . Sign tactile message is to comply with ICC/ANSI A117.1 .
2.3 MATERIALS
2.3.1 Aluminum Alloy Products
Aluminum extrusions are at least 1/8 inch thick, and aluminum plate or sheet are at least 0.0508 inch thick. Extrusions conform to ASTM B221;
plate and sheet conforms to ASTM B209. Where anodic coatings are specified, alloy conforms to AA PK-1 alloy designation 514.0. Exposed anodized aluminum finishes are as shown. Welding for aluminum products conforms to AWS D1.2/D1.2M .
2.3.2 Plastic Laminate Sheet
ANSI/NEMA LD 3 , general purpose HGS grade, 0.048 inch nominal thickness.
2.3.3 Fabrication and Manufacture
2.3.3.1 Factory Workmanship
Holes for bolts and screws are drilled or punched. Drilling and punching produces clean, true lines and surfaces. Exposed surfaces of work have a smooth finish; exposed riveting is flush. Conceal fastenings where practicable.
2.3.3.2 Dissimilar Materials
Where dissimilar metals are in contact, protect surfaces prevent galvanic or corrosive action.
2.3.4 Typeface
DA-ABA compliant font for Room Signs
2.4 GRAPHICS
Provide signage graphics for modular signs to the following:
2.4.1 Engraved Copy
Machine engrave letters, numbers, symbols, and other graphics into panel sign on face to produce precisely formed copy and sharp images, incised to
SECTION 10 14 00.20 Page 5 uniform depth. Melamine plastic engraving stock used for ADA compliant graphic is three-ply lamination contrasting color core meeting ASTM D635.
2.5 COLOR, FINISH, AND CONTRAST
Provide color as indicated on drawings
PART 3 EXECUTION
3.1 INSTALLATION
Install signs plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings.
Submit operating instructions outlining the step-by-step procedures required for system operation. The instructions include simplified diagrams for the system as installed, the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features. Provide each set permanently bound with a hard cover. The following identification must be inscribed on the covers: "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number. Submit in accordance with Section 01 78 23 OPERATING AND MAINTENANCE DATA. Mounting height and mounting location complies with 36 CFR 1191 . Install required blocking. Do not install signs on doors or other surfaces until finishes on such surfaces have been installed. Signs installed on glass surfaces are installed with matching blank back-up plates in accordance with manufacturer's instructions.
Do not install items that show visual evidence of biological growth.
3.1.1 Anchorage
Provide anchorage in accordance with approved manufacturer's instructions. Anchorage not otherwise specified or shown includes slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Provide exposed anchor and fastener materials compatible with metal to which applied with matching color and finish.
a. Signs mounted to painted gypsum board surfaces must be removable for painting maintenance.
b. Mount signs to lay-in ceiling grids with clip connections to ceiling tees.
c. Install signs mounted on metal surfaces with magnetic tape.
d. Install signs mounted on fabric surfaces with hook and loop tape or pin mount.
e. Install signs to workstation panels with panel clips.
3.1.2 Protection and Cleaning
Protect the work against damage during construction. Adjust hardware and electrical equipment for proper operation. Clean glass, frames, and other sign surfaces at completion of signage installation in accordance with the manufacturer's written instructions.
SECTION 10 14 00.20 Page 6
-- End of Section --
SECTION 10 14 00.20 Page 7
THIS PAGE INTENTIONALLY LEFT BLANK
SECTION 10 14 00.20 Page 8
| 10 14 00.20 - INTERIOR SIGNAGE |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 EXTRA MATERIALS |
| 1.4 QUALITY ASSURANCE |
| 1.4.1 Samples |
| 1.4.2 Detail Drawings |
| 1.4.3 Sign Fabricator |
| 1.4.4 Cybersecurity |
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| 1.6 WARRANTY |
| PART 2 PRODUCTS |
| 2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM |
| 2.1.1 Panel Sign Systems |
| 2.1.2 Standard Room Signs |
| 2.1.2.1 Tactile Letters, Symbols and Braille |
| 2.1.3 Message Inserts |
| 2.1.4 Type of Mounting for Signs |
| 2.1.5 Character Proportions and Heights |
| 2.2 EXIT DOOR TACTILE SIGN |
| 2.3 MATERIALS |
| 2.3.1 Aluminum Alloy Products |
| 2.3.2 Plastic Laminate Sheet |
| 2.3.3 Fabrication and Manufacture |
| 2.3.3.1 Factory Workmanship |
| 2.3.3.2 Dissimilar Materials |
2.3.4 Typeface
| 2.4 GRAPHICS |
| 2.4.1 Engraved Copy |
2.5 COLOR, FINISH, AND CONTRAST
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.1.1 Anchorage |
| 3.1.2 Protection and Cleaning |
File details come from the government source that posted it. Updated .