crouse-hinds-arktite-200a-plugs-receptacles-connectors-catalog-page.pdf
PDF 2 MB Posted
- Attached to
- Construct VM/AGE Complex
- Solicitation number
- W50S8W25RA003
- Issued by
-
Department of the Army National Guard
About this file
This document is a product catalog page for Eaton Crouse-Hinds Arktite heavy duty circuit breaking plugs, receptacles, and connectors rated for 200A, 600VAC/250VDC, with 50-400 Hz frequency range. The catalog details industrial-grade electrical connection devices designed for non-hazardous areas with NEMA 3R and NEMA 4 watertight ratings, suitable for portable electrical equipment like motor generator sets, compressors, welding equipment, and industrial machinery.
Key product features include split pin contact design providing nearly 360-degree contact, stainless steel hardware, self-wiping contacts to prevent environmental contamination, and multiple grounding styles (Style 1 and Style 2 metallic and non-metallic). The devices offer circuit breaking capabilities, with plugs through 100 amperes capable of being disconnected under load, and are available in various configurations including 2-wire, 3-wire, and 4-pole options. The catalog provides comprehensive ordering information, replacement parts details, wire size compatibility charts, and technical specifications for mechanical lug and crimp/solder termination configurations.
View the file
Other files
Show 40 more
Latest 50 of 55 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton677
1P 1P
Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty Non-hazardous areas
NEMA 4 Watertight
Applications:
Arktite® circuit breaking plugs and receptacles are used:
• To supply power to portable electrically operated devices such as motor generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems and similar equipment
• Where temporary power is needed, such as at trailers, building units, heavy machinery and similar equipment
• Wherever electrical loads must be quickly disconnected from power source
• In a typical installation, where a large machine utilizes a number of electrical motor drives and for ease of adjustment, removal, maintenance and replacement, each motor is connected by portable cord and Arktite receptacles rather than permanently wired
• In areas where dust, dirt, moisture and corrosion are a problem
• Indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants and similar industrial locations
Features:
• Circuit breaking – plugs through 100 ampere rating may be disconnected under load; 150-400 ampere units are for service disconnect use only
• Receptacles accept only plugs of the same amperage rating, style and number of poles, making it impossible to mismate, and provides for positive polarization
• Extra wide electrical spacing allows for maximum safety
• Insulator materials are the result of intensive testing; selection has been made based on highest dielectric strength, maximum mechanical and impact resistance, lowest moisture absorption and highest arc tracking resistance
• A variety of installations is possible due to the availability of several types of back boxes
• Designed to withstand rough usage and the effects of adverse environments
• Reversible interiors – 30, 60 and 100 ampere (except 30 and 60 ampere, 5-pole); Arktite plug and receptacle interiors are interchangeable using a screwdriver, making it possible to feed a normally de-energized receptacle from an energized plug with usual Arktite safety;
no energized contacts are exposed
Certifications and compliances:
• UL standards: 1203A, 1682, 1686
• CSA standard: C22.2 No. 182.1
• CE (LVD) 2006/95/EECB
AAPJ and NPJ plugs only.
BExcludes 200A and 400A APR connectors.
www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 678
1P
Split pin contact design:
• Provides nearly 360° of contact at every insertion, ensuring protection against heat rise and eliminating arcing on critical surfaces
• Continuous contact over length and circumference of mated pins provides superior safety and long-term performance
• Self-wiping at every insertion to prevent environmental contamination build-up
Combination drive stainless steel hardware
• Increases ease of installation by allowing for more than one option for installation tools
• Stainless steel external hardware eliminates corrosion on critical components and extends product life
Insulator assemblies
• Unimpeded, easy access phase and ground terminals make wire termination quick and easy
• Lug screws secured with tape to prevent them from vibrating loose and falling out during shipping
Combination slot and hex mechanical lugsC
• Increases ease of installation by allowing for more than one option for installation tools
• Hex head allows for easy achievement of specified torque value
Receptacle cover
• Automatic weatherproof seal every time plug is disengaged
• Field replaceable design allows for new cover to be threaded on quickly and easily
Arktite advantage features:
Internal plug safety insulator
• Plastic barrier between insulator body and metal housing minimizes risk of energizing handle body due to stray conductor strands
• Increases creepage and clearance protection
CE marked
• Offers a borderless solution with no additional inspection or documentation required for approval
Lockout plug
• Allows users to comply with OSHA lockout/ tagout requirements
• Ensures plug cannot be inserted into receptacle when maintenance is being performed downstream of power supply
Tri-Lock cable grip
• Three-piece design equally distributes grip around perimeter of cable
• Cable jacket does not get pinched, eliminating potential for damage to internal conductors
• Captive screws allow maximum extension of cord grip without risk of loose components
Sure-Seal cable gland
• Two gasket sizes fit entire cable range, reducing risk of improper assembly
• Gasket ratches into Tri-Lock cable grip to provide environmental protection in high vibration areas
The additional features below are called out in the illustration on this page:
The ground contact is bonded to the receptacle housing (Style 2).
Unimpeded, easy access phase and ground terminals make wire termination quick and easy.
Grounding contacts that make first and break last in the unlikely event of keyway failure.
An arc formed when the plug is being removed is instantly snuffed in the deep confined insulated arcing chamber.
A detent spring forms a parallel grounding path through the metallic plug sleeve and receptacle housing and is the first contact to make and the last to break.
The plug sleeve is keyed to the receptacle to prevent mispolarization.
The gasketing system provides unsurpassed watertight integrity (NEMA 4).
All aluminum Uni-Shell™ construction provides superior strength in abusive environments.
The Tri-Lock™ cable grip has three-piece design that equally distributes gripping power around perimeter of cable. Cord jacket does not get pinched, eliminating potential for damage to both internal conductors and external cable jacket.
Cable grip is located inside plug housing, eliminating corrosion of vital hardware and making plug maintenance easy.
The unique Sure-Seal™ cable gland has two gasket sizes which fit entire range of cable diameters, reducing risk of improper assembly. The gasket ratchets into the Tri- Lock cable grip to prevent plug from turning or loosening in high vibration areas.
Wrenching surfaces make Arktite plugs quick and easy to assemble.
Smooth and contoured design of plug housing eliminates occurrence of cable grip snagging or breaking off. Tri-Lock screws are captive so cable grip cannot come apart during assembly. Prevents critical screws from getting lost during installation.
Plastic sleeve between insulator body and housing minimizes possibility of electrical shock in event of ground failure. Increases creepage and clearance protection.
Plug housing
• Smooth design eliminates occurrence of cable grip snagging or breaking off
• Houses Tri-Lock cable grip to eliminate corrosion of vital hardware and increase ease of maintenance
C60, 100 and 150A offering.
Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty Non-hazardous areas
NEMA 4 Watertight www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton679
1P
Grounding – Style 1 vs. Style 2:
Eaton’s Crouse-Hinds series Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles. NEC reference 250.138 (A) and (B).
Style 1 – metallic A Style 1 plug is one in which the grounding conductor in the flexible cable is bonded to the plug sleeve by a pressure connector. A Style 1 receptacle is one which is grounded by virtue of the fact that it is an integral part of a grounded conduit system. On insertion, the plug sleeve makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded.
Style 1 ground conductor attaches to shell
Style 2 – metallic A Style 2 metallic housing plug is one in which the grounding conductor in the flexible cable is bonded to the extra (grounding) pole and metal plug sleeve by a pressure connector. A Style 2 metallic housing receptacle is one in which the extra (grounding) pole is electrically connected to the equipment grounding conductor and the metal receptacle housing which itself is grounded by virtue of the fact that it is an integral part of a grounded conduit system. In Style 2 non-metallic housing plugs and receptacles, the extra pole is used for grounding since the housings are non-conductive.
Metal shelled type
Style 2 ground conductor attaches to contact, which is bonded to shell
Style 2 – non-metallic In a Style 2 receptacle, the grounding connection is made before line and load poles engage, and is broken after the line load poles disengage. Furthermore, upon insertion, the plug sleeve of metal shelled units makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded.
Made of non-metallic Krydon material
Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 680
1P
D150A, 200A and 400A rated units are for service disconnect use only.
The mating plug has a cast groove located on the outside of the plug sleeve.
This groove lines up with the raised rib.
Arktite receptacles have a cast raised rib located inside the receptacle sleeve.
The location of the rib is in a specific relationship to the receptacle insulator that houses the contacts.
Standard materials:
• Metallic receptacle housings, plug and cord connector bodies – high impact strength copper-free aluminum
• Non-metallic receptacles, plugs and cord connectors – Krydon fiberglass-reinforced polyester
• Back boxes (20, 30, 60, 100, 150, 200 amperes) – cast aluminum; 400 amperes – Feraloy iron alloy
• Insulation (metallic products) (2-, 3-, 4-pole) 30, 60, 100, 200, 400 amperes
– fiberglass-reinforced polyester; 20, 30 amperes (5-pole) – melamine
• Contacts: pressure, solder, binding screw
– brass; crimp/solder 20, 30, 60, 100 amperes – leaded red brass; crimp/solder 150, 200, 400 amperes – telurium copper
Standard finishes:
• Feraloy – electrogalvanized and aluminum acrylic paint
• Aluminum – natural
• Krydon fiberglass-reinforced polyester – gray
• Fiberglass-reinforced polyester insulation –
(red)
• Melamine – natural (brown)
• Brass – natural
• Leaded red brass – electro-tin-plate
Accessories:
• Accessories include a variety of angle adapters, panel adapters and back boxes for Arktite receptacles (see pages 697-700)
• Included throughout Section 1P are wire mesh cable grips and protective caps for Arktite plugs
Typical installation
Options:
Description Suffix
• Reverse service ................................... S22 Receptacle assembled with plug interior
(exposed contacts); plug assembled with receptacle interior (recessed contacts)
For applications where plug is energized to feed normally de-energized receptacle
Available on 30A-400A units
• Special polarity ....................................... S4 Receptacle interior rotated 221/2° to right and plug changed to match (see photo at right)
For use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages and/or frequencies
Prevents insertion of a plug in a receptacle with different electrical rating
Available on 20A-400A units
• Corro-free epoxy powder finish for added corrosion resistance................ S752
Available on 20A-400A units
Arktite heavy duty circuit breakingD plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton681
1P
E150A, 200A and 400A rated units are for service disconnect use only.
FHorsepower ratings are based on Eaton’s Crouse-Hinds Division testing in which locked rotor currents were interrupted by withdrawing the plug from the receptacle. It is highly recommended, however, that such use be limited to emergency conditions only, and that a horsepower rated switch be used for motor disconnect.
GThis guide is for reference only. Consult your local electrical codes before installation.
HEaton’s Crouse-Hinds Division does not recommend our plug and receptacle be used for disconnect under load.
IDo not use wire size smaller than minimum size recommended.
JSmaller sizes may be used with well reducers – information available upon request.
Horsepower ratings:
Locked rotor interrupting
Maximum horsepower for plug and receptacle combinations by input voltageG:
The following values are typical horsepower ratings based on NEC Article 430 tables. HP ratings are based on the largest conductor size for each plug and receptacle combination per the wire size table below.
Wire sizes:
The table below lists the diameter of the wire recess in Arktite plug and receptacle contacts so that maximum size of bare conductor can be figured. Range of wire sizes shown in table is intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely.
Diameter of wire recess in plug and receptacle contacts:
Motor horsepowerF
Amperage plug and receptacle 120V 240V 480V 600V
Single-phase electrical system
30 2 3 7.5 10 60 5 10 25 20 100 10 20 200 15 40 Three-phase electrical system
30 3 5 10 10 60 10 20 40 50 100 15 30 40 25 200 30 60 25 15
Motor horsepowerH
Amperage plug and receptacle 240V 480V 600V
30 15 30 40 60 20 40 50 100 30 60 75 150 40 75 100 200 60 125 150
Wire sizeI
Amperage Contact type Diameter of recess Building Extra flex
20 Binding screw N/A #14 - #12 #14 - #12 30 (2-, 3-, 4-pole) Pressure 0.281 #10 - #6 #10 - #8 30 (2-, 3-, 4-pole) Crimp/solder 0.180 #10 - #8J #10 - #8 30 (5-pole) Solder 0.188 #12 - #6 #12- #8 60 (2-, 3-, 4-, 5-pole) Pressure 0.312 #6 - #4 #8 - #4 60 (3-, 4-pole) Crimp/solder 0.277 #6 - #4J #8 - #4 100 (2-, 3-, 4-pole) Pressure 0.390 #4 - #1 #4 - #2 100 (3-, 4-pole) Crimp/solder 0.390 #2 - #1J #2 - #2 150 (4-pole) Pressure 0.390 #2 - 2/0 #2 - 1/0 200 (3-, 4-pole) Pressure 0.687 2/0 - 4/0 2/0 - 3/0 200 (Std. 3-, 4-pole) Crimp/solder 0.560 #1 - 4/0 #1 - 3/0 200 (Lg. 3-, 4-pole) Crimp/solder 0.750 4/0 - 250MCM 3/0 - 250MCM 400 (Std. 3-, 4-pole) Crimp/solder 0.840 250 - 500MCM 250 - 400MCM 400 (Lg. 3-, 4-pole) Crimp/solder 1.250 500 - 1000MCM 400 - 750MCM
Arktite heavy duty circuit breakingE plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton689
1P
Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50A-400 Hz
NEMA 3R
See pages 677-681 for general applications, features, grounding, standard materials and finishes, options, accessories, compliances, electrical rating ranges and wire sizes.
Dimensions (in inches):
AREA assembly
CPK plug closure caps
Applications:
CPK caps for Arktite plugs are used:
• Where portable equipment is on a standby basis and plugs are not in use
• To effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion
• With 30, 60, 100, 150 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing
Standard material:
• Copper-free aluminum
Standard finish:
• Natural
Wire mesh grips
Applications:
Wire mesh grips are used:
• To provide secure cable termination
• To extend cable life
• With 20, 200 and 400 ampere plugs
Features:
• Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure
• Absorb longitudinal stresses placed on the point of termination caused by pulling the cable
• Gripping action increases in direct proportion to amount of tension applied to cable
Standard material and finish:
• Stainless steel wire braid – natural
Ordering Information:
PANEL CUTOUT DIAMETER Ø 4.61
[142.9] 5.63
[142.9] 5.63
[168.3] Ø 6.63
[180.7] 7.11
[227.5] 8.96
AR receptacle AP plug APR connector
Features:
• Grounding contact wire terminators will accommodate ground wire of same size as phase wire
• Spring band contact design provides multiple points of electrical contact; improves electrical reliability and significantly reduces effort required for insertion and withdrawal
• Crimp/solder and mechanical lug type contacts are available
• Large wire wells are available for “extra flexible” wire
• Larger wire well size connectors will interchange with connectors of other wire well size of same amperage and contact configuration
• Mechanical lug connectors will interchange with crimp/solder connectors of the same amperage and contact configuration
• Self-closing spring doors on receptacles and cord connectors provide environmental sealing
• Threaded nuts provide positive plug retention
• Two-piece plug and cord connector design provides easy installation
1. For listing of additional back boxes, see page 698.
2. S22 suffix for reverse interiors is available from factory only.
Field conversion cannot be done.
3. Crimp/solder interiors cannot be converted to lug interiors.
4. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts.
AFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.
Ordering information:
Config. Cat. #
4P CPK104
Plug cable range Grip range Nominal grip length (in.) Cat. #
1.375 - 1.875” 1.375 - 1.625” 8 K163
1.625 - 1.875” 11 K188
1.875 - 2.500” 1.875 - 2.000” 10 K200
2.000 - 2.250” 113/4 K225 www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 690
1P
BFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.
Receptacle assembly Receptacle with mechanical lug
Mating plug Mating connector
Ordering information – mechanical lug termination:
Receptacle assembly with AJ back boxes and angle adapters
Receptacle housings only Mating plugs Mating connectors
Description Hub size Cat. # Cat. # Cable dia. Cat. # Cat. #
Style 1 – wire well takes 0.687” maximum conductor size
4-wire, 4-pole
2” AREAL20416
ARL2041
0.875 - 1.375” APL20455 APRL20415
21/2” AREAL20417 1.375 - 1.875” APL20457 APRL20417
1.875 - 2.500” APL20458 APRL20418
2.500 - 3.000” APL204513 APRL204113
Style 2 – wire well takes 0.687” maximum conductor size
3-wire, 4-pole
11/2” AREAL20425
ARL2042
0.875 - 1.375” APL20465 APRL20425
2” AREAL20426 1.375 - 1.875” APL20467 APRL20427
21/2” AREAL20427 1.875 - 2.500” APL20468 APRL20428
Ordering information – crimp/solder termination:
Receptacle assembly with AJ back boxes and angle adapters
Receptacle housings only Mating plugs Mating connectors
Description Hub size Cat. # Cat. # Cable dia. Cat. # Cat. #
Style 1 – wire well takes 0.56” maximum conductor size
4-wire, 4-pole
2” AREA20416
AR2041
0.875 - 1.375” AP20455 APR20415
21/2” AREA20417 1.375 - 1.875” AP20457 APR20417
1.875 - 2.500” AP20458 APR20418
Style 1 – wire well takes 0.75” maximum conductor size
4-wire, 4-pole
2” AREA204126
AR20412
1.375 - 1.875” AP204511 APR204111
21/2” AREA204127 1.875 - 2.500” AP204512 APR204112
2.500 - 3.000” AP204513 APR204113
Style 2 – wire well takes 0.56” maximum conductor size
3-wire, 4-pole
11/2” AREA20425
AR2042
0.875 - 1.375” AP20465 APR20425
2” AREA20426 1.375 - 1.875” AP20467 APR20427
21/2” AREA20427 1.875 - 2.500” AP20468 APR20428
Style 2 – wire well takes 0.75” maximum conductor size
3-wire, 4-pole
11/2” AREA204225
AR20422
1.375 - 1.875” AP204611 APR204211
2” AREA204226 1.875 - 2.500” AP204612 APR204212
21/2” AREA204227
Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50B-400 Hz
NEMA 3R
1147492223N Highlight
1147492223N Highlight www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton691
1P
Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50C-400 Hz
Weatherproof
CFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.
Replacement parts:
Cord grip assembly Plug clamp nut Recept. spring door
Replacement pin and sleeve contacts:
Receptacle interior Plug interior Brass retaining shoe
Configuration Cat. # 0.56” wire well
Cat. # 0.75” wire well
Cat. # 0.56” wire well
Cat. # 0.75” wire well
Cat. # 0.56” wire well
Cat. # 0.75” wire well
200A standard and S4
2W, 3P ATP401 ATP402 ATP433 ATP434 0490335 0490335
3W, 3P ATP397 ATP398 ATP429 ATP430 0490327 0490328
3W, 4P ATP403 ATP404 ATP435 ATP436 0490337 0490337
4W, 4P ATP399 ATP400 ATP431 ATP432 0490331 0490332
200A ST22 and S4 S22
2W, 3P ATP417 ATP418 ATP449 ATP450 0490335 0490335
3W, 3P ATP413 ATP414 ATP445 ATP446 0490327 0490328
3W, 4P ATP419 ATP420 ATP451 ATP452 0490337 0490337
4W, 4P ATP415 ATP416 ATP447 ATP448 0490331 0490332
Cord dia. range Cat. #
0.875 - 1.375” AP2 KIT1 M80
1.375 - 1.875” AP2 KIT2 M80
1.875 - 2.500” AP2 KIT3 M80
Config. Cat. #
2W, 3P AP:04019653W, 3P
2W, 3P AP:04019643W, 4P
Cat. #
AR:0401502-2
AR:0401502-1
Receptacle Plug
Type Cat. # Cat. # Cat. # Cat. #
200A standard and S4 0.56” wire well 0.75” wire well 0.56” wire well 0.75” wire well
Phase contact 0490339 0490340 0490319 0490320 Ground contact 0490343 0490344 0490323 0490324
200A S22 and S4 S22 0.56” wire well 0.75” wire well 0.56” wire well 0.75” wire well
Phase contact 0490351 0490352 0490355T 0490356 Ground contact 0490347 0490348 0490359 0490360
200A mechanical lug 0.687” wire well 0.687” wire well
Phase contact ARL:0403688 1 APL:0403678 1 Ground contact ARL:0403687 1 APL:0403677 1
File details come from the government source that posted it. Updated .