crouse-hinds-arktite-200a-plugs-receptacles-connectors-catalog-page.pdf

PDF 2 MB Posted

Attached to
Construct VM/AGE Complex
Solicitation number
W50S8W25RA003
Issued by

About this file

This document is a product catalog page for Eaton Crouse-Hinds Arktite heavy duty circuit breaking plugs, receptacles, and connectors rated for 200A, 600VAC/250VDC, with 50-400 Hz frequency range. The catalog details industrial-grade electrical connection devices designed for non-hazardous areas with NEMA 3R and NEMA 4 watertight ratings, suitable for portable electrical equipment like motor generator sets, compressors, welding equipment, and industrial machinery.

Key product features include split pin contact design providing nearly 360-degree contact, stainless steel hardware, self-wiping contacts to prevent environmental contamination, and multiple grounding styles (Style 1 and Style 2 metallic and non-metallic). The devices offer circuit breaking capabilities, with plugs through 100 amperes capable of being disconnected under load, and are available in various configurations including 2-wire, 3-wire, and 4-pole options. The catalog provides comprehensive ordering information, replacement parts details, wire size compatibility charts, and technical specifications for mechanical lug and crimp/solder termination configurations.

View the file

Other files

File Type Posted
E-701 - PANEL SCHEDULES.pdf PDF
E-702 - PANEL SCHEDULES.pdf PDF
VM_AGE RFIs Answered - Version 4.xlsx XLSX spreadsheet
E-121 - FIRST FLOOR POWER PLAN - AREA 1.pdf PDF
E-123 - ELECTRICAL POWER AND LIGHTING PLANS - PARKING SHEDS.pdf PDF
E-101 - GROUNDING PLAN.pdf PDF
E-703 - PANEL SCHEDULES.pdf PDF
E-122 - FIRST FLOOR POWER PLAN - AREA 2.pdf PDF
60554859_WY-ANG_VMAF_S22 - Sheet - S-002.pdf PDF
08 36 19 - BR.pdf PDF
MS27265A.PDF PDF
27 51 16 - BR.pdf PDF
60554859_WY-ANG_VMAF_S22 - Sheet - S-504.pdf PDF
BASE MAP 24 1TO400.pdf PDF
10 14 00.20 - BR.pdf PDF
VM_AGE RFIs Answered - Version 3.xlsx XLSX spreadsheet
MS90362C.PDF PDF
Solicitation Amendment W50S8W25RA0030007 SF 30.pdf PDF
32 13 13.06.pdf PDF
08 33 23 - BR.pdf PDF
x1806-71_cpp.pdf PDF
Solicitation Amendment W50S8W25RA0030006 SF 30.pdf PDF
ANG Sustainability Requirements Scoresheet.pdf PDF
20230610_060152.jpg JPG image
9000 Series.pdf PDF
1994 Asbestos Survey - B21_23_24.pdf PDF
Jack Tester Info.PDF PDF
20230610_060238.jpg JPG image
Solicitation Amendment W50S8W25RA0030005 SF 30.pdf PDF
20230610_062744.jpg JPG image
VM_AGE RFIs Answered - Version 2.xlsx XLSX spreadsheet
Solicitation Amendment W50S8W25RA0030004 SF 30.pdf PDF
AECOM Drawings.zip ZIP file
Existing VM_AGE as_builts.zip ZIP file
GCFI Equipment.zip ZIP file
Communications UFC.zip ZIP file
Fire Spec List.zip ZIP file
Geotechnical Report.zip ZIP file
VM_AGE Questions and Answers Version 1.xlsx XLSX spreadsheet
Pavement Evaluations.zip ZIP file
TEMPLATE - H.02 Progress Schedule AF3064 (23-C-XXXX).pdf PDF
Laydown Areas.zip ZIP file
Solicitation Amendment W50S8W25RA0030003 SF 30.pdf PDF
Solicitation Amendment W50S8W25RA0030002 SF 30.pdf PDF
B.07 Pre-proposal Conference Site Visit Slides (25-R-A003).pptx PPTX presentation
Pre-Proposal Conference Attendance Roster.pdf PDF
Solicitation Amendment W50S8W25RA0030001 SF 30.pdf PDF
B.08 Attachment 7 - Entry Authorization Form.pdf PDF
B.08 Attachment 4 - Contractor Hazmat Usage Tracking Instructions.pdf PDF
Attachment 1 - SOW- Construct VM_AGE Complex - Aug 22 2024.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton677

1P 1P

Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty Non-hazardous areas

NEMA 4 Watertight

Applications:

Arktite® circuit breaking plugs and receptacles are used:

• To supply power to portable electrically operated devices such as motor generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems and similar equipment

• Where temporary power is needed, such as at trailers, building units, heavy machinery and similar equipment

• Wherever electrical loads must be quickly disconnected from power source

• In a typical installation, where a large machine utilizes a number of electrical motor drives and for ease of adjustment, removal, maintenance and replacement, each motor is connected by portable cord and Arktite receptacles rather than permanently wired

• In areas where dust, dirt, moisture and corrosion are a problem

• Indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants and similar industrial locations

Features:

• Circuit breaking – plugs through 100 ampere rating may be disconnected under load; 150-400 ampere units are for service disconnect use only

• Receptacles accept only plugs of the same amperage rating, style and number of poles, making it impossible to mismate, and provides for positive polarization

• Extra wide electrical spacing allows for maximum safety

• Insulator materials are the result of intensive testing; selection has been made based on highest dielectric strength, maximum mechanical and impact resistance, lowest moisture absorption and highest arc tracking resistance

• A variety of installations is possible due to the availability of several types of back boxes

• Designed to withstand rough usage and the effects of adverse environments

• Reversible interiors – 30, 60 and 100 ampere (except 30 and 60 ampere, 5-pole); Arktite plug and receptacle interiors are interchangeable using a screwdriver, making it possible to feed a normally de-energized receptacle from an energized plug with usual Arktite safety;

no energized contacts are exposed

Certifications and compliances:

• UL standards: 1203A, 1682, 1686

• CSA standard: C22.2 No. 182.1

• CE (LVD) 2006/95/EECB

AAPJ and NPJ plugs only.

BExcludes 200A and 400A APR connectors.

www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 678

1P

Split pin contact design:

• Provides nearly 360° of contact at every insertion, ensuring protection against heat rise and eliminating arcing on critical surfaces

• Continuous contact over length and circumference of mated pins provides superior safety and long-term performance

• Self-wiping at every insertion to prevent environmental contamination build-up

Combination drive stainless steel hardware

• Increases ease of installation by allowing for more than one option for installation tools

• Stainless steel external hardware eliminates corrosion on critical components and extends product life

Insulator assemblies

• Unimpeded, easy access phase and ground terminals make wire termination quick and easy

• Lug screws secured with tape to prevent them from vibrating loose and falling out during shipping

Combination slot and hex mechanical lugsC

• Increases ease of installation by allowing for more than one option for installation tools

• Hex head allows for easy achievement of specified torque value

Receptacle cover

• Automatic weatherproof seal every time plug is disengaged

• Field replaceable design allows for new cover to be threaded on quickly and easily

Arktite advantage features:

Internal plug safety insulator

• Plastic barrier between insulator body and metal housing minimizes risk of energizing handle body due to stray conductor strands

• Increases creepage and clearance protection

CE marked

• Offers a borderless solution with no additional inspection or documentation required for approval

Lockout plug

• Allows users to comply with OSHA lockout/ tagout requirements

• Ensures plug cannot be inserted into receptacle when maintenance is being performed downstream of power supply

Tri-Lock cable grip

• Three-piece design equally distributes grip around perimeter of cable

• Cable jacket does not get pinched, eliminating potential for damage to internal conductors

• Captive screws allow maximum extension of cord grip without risk of loose components

Sure-Seal cable gland

• Two gasket sizes fit entire cable range, reducing risk of improper assembly

• Gasket ratches into Tri-Lock cable grip to provide environmental protection in high vibration areas

The additional features below are called out in the illustration on this page:

The ground contact is bonded to the receptacle housing (Style 2).

Unimpeded, easy access phase and ground terminals make wire termination quick and easy.

Grounding contacts that make first and break last in the unlikely event of keyway failure.

An arc formed when the plug is being removed is instantly snuffed in the deep confined insulated arcing chamber.

A detent spring forms a parallel grounding path through the metallic plug sleeve and receptacle housing and is the first contact to make and the last to break.

The plug sleeve is keyed to the receptacle to prevent mispolarization.

The gasketing system provides unsurpassed watertight integrity (NEMA 4).

All aluminum Uni-Shell™ construction provides superior strength in abusive environments.

The Tri-Lock™ cable grip has three-piece design that equally distributes gripping power around perimeter of cable. Cord jacket does not get pinched, eliminating potential for damage to both internal conductors and external cable jacket.

Cable grip is located inside plug housing, eliminating corrosion of vital hardware and making plug maintenance easy.

The unique Sure-Seal™ cable gland has two gasket sizes which fit entire range of cable diameters, reducing risk of improper assembly. The gasket ratchets into the Tri- Lock cable grip to prevent plug from turning or loosening in high vibration areas.

Wrenching surfaces make Arktite plugs quick and easy to assemble.

Smooth and contoured design of plug housing eliminates occurrence of cable grip snagging or breaking off. Tri-Lock screws are captive so cable grip cannot come apart during assembly. Prevents critical screws from getting lost during installation.

Plastic sleeve between insulator body and housing minimizes possibility of electrical shock in event of ground failure. Increases creepage and clearance protection.

Plug housing

• Smooth design eliminates occurrence of cable grip snagging or breaking off

• Houses Tri-Lock cable grip to eliminate corrosion of vital hardware and increase ease of maintenance

C60, 100 and 150A offering.

Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty Non-hazardous areas

NEMA 4 Watertight www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton679

1P

Grounding – Style 1 vs. Style 2:

Eaton’s Crouse-Hinds series Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles. NEC reference 250.138 (A) and (B).

Style 1 – metallic A Style 1 plug is one in which the grounding conductor in the flexible cable is bonded to the plug sleeve by a pressure connector. A Style 1 receptacle is one which is grounded by virtue of the fact that it is an integral part of a grounded conduit system. On insertion, the plug sleeve makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded.

Style 1 ground conductor attaches to shell

Style 2 – metallic A Style 2 metallic housing plug is one in which the grounding conductor in the flexible cable is bonded to the extra (grounding) pole and metal plug sleeve by a pressure connector. A Style 2 metallic housing receptacle is one in which the extra (grounding) pole is electrically connected to the equipment grounding conductor and the metal receptacle housing which itself is grounded by virtue of the fact that it is an integral part of a grounded conduit system. In Style 2 non-metallic housing plugs and receptacles, the extra pole is used for grounding since the housings are non-conductive.

Metal shelled type

Style 2 ground conductor attaches to contact, which is bonded to shell

Style 2 – non-metallic In a Style 2 receptacle, the grounding connection is made before line and load poles engage, and is broken after the line load poles disengage. Furthermore, upon insertion, the plug sleeve of metal shelled units makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded.

Made of non-metallic Krydon material

Arktite heavy duty circuit breaking plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 680

1P

D150A, 200A and 400A rated units are for service disconnect use only.

The mating plug has a cast groove located on the outside of the plug sleeve.

This groove lines up with the raised rib.

Arktite receptacles have a cast raised rib located inside the receptacle sleeve.

The location of the rib is in a specific relationship to the receptacle insulator that houses the contacts.

Standard materials:

• Metallic receptacle housings, plug and cord connector bodies – high impact strength copper-free aluminum

• Non-metallic receptacles, plugs and cord connectors – Krydon fiberglass-reinforced polyester

• Back boxes (20, 30, 60, 100, 150, 200 amperes) – cast aluminum; 400 amperes – Feraloy iron alloy

• Insulation (metallic products) (2-, 3-, 4-pole) 30, 60, 100, 200, 400 amperes

– fiberglass-reinforced polyester; 20, 30 amperes (5-pole) – melamine

• Contacts: pressure, solder, binding screw

– brass; crimp/solder 20, 30, 60, 100 amperes – leaded red brass; crimp/solder 150, 200, 400 amperes – telurium copper

Standard finishes:

• Feraloy – electrogalvanized and aluminum acrylic paint

• Aluminum – natural

• Krydon fiberglass-reinforced polyester – gray

• Fiberglass-reinforced polyester insulation –

(red)

• Melamine – natural (brown)

• Brass – natural

• Leaded red brass – electro-tin-plate

Accessories:

• Accessories include a variety of angle adapters, panel adapters and back boxes for Arktite receptacles (see pages 697-700)

• Included throughout Section 1P are wire mesh cable grips and protective caps for Arktite plugs

Typical installation

Options:

Description Suffix

• Reverse service ................................... S22 Receptacle assembled with plug interior

(exposed contacts); plug assembled with receptacle interior (recessed contacts)

For applications where plug is energized to feed normally de-energized receptacle

Available on 30A-400A units

• Special polarity ....................................... S4 Receptacle interior rotated 221/2° to right and plug changed to match (see photo at right)

For use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages and/or frequencies

Prevents insertion of a plug in a receptacle with different electrical rating

Available on 20A-400A units

• Corro-free epoxy powder finish for added corrosion resistance................ S752

Available on 20A-400A units

Arktite heavy duty circuit breakingD plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton681

1P

E150A, 200A and 400A rated units are for service disconnect use only.

FHorsepower ratings are based on Eaton’s Crouse-Hinds Division testing in which locked rotor currents were interrupted by withdrawing the plug from the receptacle. It is highly recommended, however, that such use be limited to emergency conditions only, and that a horsepower rated switch be used for motor disconnect.

GThis guide is for reference only. Consult your local electrical codes before installation.

HEaton’s Crouse-Hinds Division does not recommend our plug and receptacle be used for disconnect under load.

IDo not use wire size smaller than minimum size recommended.

JSmaller sizes may be used with well reducers – information available upon request.

Horsepower ratings:

Locked rotor interrupting

Maximum horsepower for plug and receptacle combinations by input voltageG:

The following values are typical horsepower ratings based on NEC Article 430 tables. HP ratings are based on the largest conductor size for each plug and receptacle combination per the wire size table below.

Wire sizes:

The table below lists the diameter of the wire recess in Arktite plug and receptacle contacts so that maximum size of bare conductor can be figured. Range of wire sizes shown in table is intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely.

Diameter of wire recess in plug and receptacle contacts:

Motor horsepowerF

Amperage plug and receptacle 120V 240V 480V 600V

Single-phase electrical system

30 2 3 7.5 10 60 5 10 25 20 100 10 20 200 15 40 Three-phase electrical system

30 3 5 10 10 60 10 20 40 50 100 15 30 40 25 200 30 60 25 15

Motor horsepowerH

Amperage plug and receptacle 240V 480V 600V

30 15 30 40 60 20 40 50 100 30 60 75 150 40 75 100 200 60 125 150

Wire sizeI

Amperage Contact type Diameter of recess Building Extra flex

20 Binding screw N/A #14 - #12 #14 - #12 30 (2-, 3-, 4-pole) Pressure 0.281 #10 - #6 #10 - #8 30 (2-, 3-, 4-pole) Crimp/solder 0.180 #10 - #8J #10 - #8 30 (5-pole) Solder 0.188 #12 - #6 #12- #8 60 (2-, 3-, 4-, 5-pole) Pressure 0.312 #6 - #4 #8 - #4 60 (3-, 4-pole) Crimp/solder 0.277 #6 - #4J #8 - #4 100 (2-, 3-, 4-pole) Pressure 0.390 #4 - #1 #4 - #2 100 (3-, 4-pole) Crimp/solder 0.390 #2 - #1J #2 - #2 150 (4-pole) Pressure 0.390 #2 - 2/0 #2 - 1/0 200 (3-, 4-pole) Pressure 0.687 2/0 - 4/0 2/0 - 3/0 200 (Std. 3-, 4-pole) Crimp/solder 0.560 #1 - 4/0 #1 - 3/0 200 (Lg. 3-, 4-pole) Crimp/solder 0.750 4/0 - 250MCM 3/0 - 250MCM 400 (Std. 3-, 4-pole) Crimp/solder 0.840 250 - 500MCM 250 - 400MCM 400 (Lg. 3-, 4-pole) Crimp/solder 1.250 500 - 1000MCM 400 - 750MCM

Arktite heavy duty circuit breakingE plugs and receptacles Industrial heavy duty www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton689

1P

Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50A-400 Hz

NEMA 3R

See pages 677-681 for general applications, features, grounding, standard materials and finishes, options, accessories, compliances, electrical rating ranges and wire sizes.

Dimensions (in inches):

AREA assembly

CPK plug closure caps

Applications:

CPK caps for Arktite plugs are used:

• Where portable equipment is on a standby basis and plugs are not in use

• To effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion

• With 30, 60, 100, 150 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing

Standard material:

• Copper-free aluminum

Standard finish:

• Natural

Wire mesh grips

Applications:

Wire mesh grips are used:

• To provide secure cable termination

• To extend cable life

• With 20, 200 and 400 ampere plugs

Features:

• Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure

• Absorb longitudinal stresses placed on the point of termination caused by pulling the cable

• Gripping action increases in direct proportion to amount of tension applied to cable

Standard material and finish:

• Stainless steel wire braid – natural

Ordering Information:

PANEL CUTOUT DIAMETER Ø 4.61

[142.9] 5.63

[142.9] 5.63

[168.3] Ø 6.63

[180.7] 7.11

[227.5] 8.96

AR receptacle AP plug APR connector

Features:

• Grounding contact wire terminators will accommodate ground wire of same size as phase wire

• Spring band contact design provides multiple points of electrical contact; improves electrical reliability and significantly reduces effort required for insertion and withdrawal

• Crimp/solder and mechanical lug type contacts are available

• Large wire wells are available for “extra flexible” wire

• Larger wire well size connectors will interchange with connectors of other wire well size of same amperage and contact configuration

• Mechanical lug connectors will interchange with crimp/solder connectors of the same amperage and contact configuration

• Self-closing spring doors on receptacles and cord connectors provide environmental sealing

• Threaded nuts provide positive plug retention

• Two-piece plug and cord connector design provides easy installation

1. For listing of additional back boxes, see page 698.

2. S22 suffix for reverse interiors is available from factory only.

Field conversion cannot be done.

3. Crimp/solder interiors cannot be converted to lug interiors.

4. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts.

AFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.

Ordering information:

Config. Cat. #

4P CPK104

Plug cable range Grip range Nominal grip length (in.) Cat. #

1.375 - 1.875” 1.375 - 1.625” 8 K163

1.625 - 1.875” 11 K188

1.875 - 2.500” 1.875 - 2.000” 10 K200

2.000 - 2.250” 113/4 K225 www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton 690

1P

BFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.

Receptacle assembly Receptacle with mechanical lug

Mating plug Mating connector

Ordering information – mechanical lug termination:

Receptacle assembly with AJ back boxes and angle adapters

Receptacle housings only Mating plugs Mating connectors

Description Hub size Cat. # Cat. # Cable dia. Cat. # Cat. #

Style 1 – wire well takes 0.687” maximum conductor size

4-wire, 4-pole

2” AREAL20416

ARL2041

0.875 - 1.375” APL20455 APRL20415

21/2” AREAL20417 1.375 - 1.875” APL20457 APRL20417

1.875 - 2.500” APL20458 APRL20418

2.500 - 3.000” APL204513 APRL204113

Style 2 – wire well takes 0.687” maximum conductor size

3-wire, 4-pole

11/2” AREAL20425

ARL2042

0.875 - 1.375” APL20465 APRL20425

2” AREAL20426 1.375 - 1.875” APL20467 APRL20427

21/2” AREAL20427 1.875 - 2.500” APL20468 APRL20428

Ordering information – crimp/solder termination:

Receptacle assembly with AJ back boxes and angle adapters

Receptacle housings only Mating plugs Mating connectors

Description Hub size Cat. # Cat. # Cable dia. Cat. # Cat. #

Style 1 – wire well takes 0.56” maximum conductor size

4-wire, 4-pole

2” AREA20416

AR2041

0.875 - 1.375” AP20455 APR20415

21/2” AREA20417 1.375 - 1.875” AP20457 APR20417

1.875 - 2.500” AP20458 APR20418

Style 1 – wire well takes 0.75” maximum conductor size

4-wire, 4-pole

2” AREA204126

AR20412

1.375 - 1.875” AP204511 APR204111

21/2” AREA204127 1.875 - 2.500” AP204512 APR204112

2.500 - 3.000” AP204513 APR204113

Style 2 – wire well takes 0.56” maximum conductor size

3-wire, 4-pole

11/2” AREA20425

AR2042

0.875 - 1.375” AP20465 APR20425

2” AREA20426 1.375 - 1.875” AP20467 APR20427

21/2” AREA20427 1.875 - 2.500” AP20468 APR20428

Style 2 – wire well takes 0.75” maximum conductor size

3-wire, 4-pole

11/2” AREA204225

AR20422

1.375 - 1.875” AP204611 APR204211

2” AREA204226 1.875 - 2.500” AP204612 APR204212

21/2” AREA204227

Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50B-400 Hz

NEMA 3R

1147492223N Highlight

1147492223N Highlight www.eaton.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2022 Eaton691

1P

Arktite heavy duty circuit breaking receptacle assemblies 200A, 600 VAC/250 VDC, 50C-400 Hz

Weatherproof

CFor use on systems less than 60 Hz, the receptacles, plugs and connectors are for disconnect use only.

Replacement parts:

Cord grip assembly Plug clamp nut Recept. spring door

Replacement pin and sleeve contacts:

Receptacle interior Plug interior Brass retaining shoe

Configuration Cat. # 0.56” wire well

Cat. # 0.75” wire well

Cat. # 0.56” wire well

Cat. # 0.75” wire well

Cat. # 0.56” wire well

Cat. # 0.75” wire well

200A standard and S4

2W, 3P ATP401 ATP402 ATP433 ATP434 0490335 0490335

3W, 3P ATP397 ATP398 ATP429 ATP430 0490327 0490328

3W, 4P ATP403 ATP404 ATP435 ATP436 0490337 0490337

4W, 4P ATP399 ATP400 ATP431 ATP432 0490331 0490332

200A ST22 and S4 S22

2W, 3P ATP417 ATP418 ATP449 ATP450 0490335 0490335

3W, 3P ATP413 ATP414 ATP445 ATP446 0490327 0490328

3W, 4P ATP419 ATP420 ATP451 ATP452 0490337 0490337

4W, 4P ATP415 ATP416 ATP447 ATP448 0490331 0490332

Cord dia. range Cat. #

0.875 - 1.375” AP2 KIT1 M80

1.375 - 1.875” AP2 KIT2 M80

1.875 - 2.500” AP2 KIT3 M80

Config. Cat. #

2W, 3P AP:04019653W, 3P

2W, 3P AP:04019643W, 4P

Cat. #

AR:0401502-2

AR:0401502-1

Receptacle Plug

Type Cat. # Cat. # Cat. # Cat. #

200A standard and S4 0.56” wire well 0.75” wire well 0.56” wire well 0.75” wire well

Phase contact 0490339 0490340 0490319 0490320 Ground contact 0490343 0490344 0490323 0490324

200A S22 and S4 S22 0.56” wire well 0.75” wire well 0.56” wire well 0.75” wire well

Phase contact 0490351 0490352 0490355T 0490356 Ground contact 0490347 0490348 0490359 0490360

200A mechanical lug 0.687” wire well 0.687” wire well

Phase contact ARL:0403688 1 APL:0403678 1 Ground contact ARL:0403687 1 APL:0403677 1

File details come from the government source that posted it. Updated .