This document is an electrical power plan drawing (Sheet E-121) for the Wyoming Air National Guard's Combined Vehicle Maintenance & AGE Facility project. The detailed floor power plan for Area 1 includes specific electrical requirements for various rooms and spaces, with particular attention to specialized areas like the Refueler Maintenance space (Room 1116), which is classified as a Class 1 Division 2 hazardous location requiring specific electrical equipment and installation standards.

The drawing provides comprehensive power layout details, including receptacle placements, specialized power requirements for equipment such as vehicle lifts, cranes, roll-up doors, appliances (refrigerator, microwave, washer, dryer), and specific electrical considerations for different spaces. Notable technical specifications include requirements for electrical devices in hazardous locations, conduit installation standards, and precise mounting instructions for receptacles, with multiple keynotes detailing specific power provisions for various equipment and rooms. The document is part of a B3 Submission (100%) dated 11/22/2024, associated with Solicitation Number W9133L-16-D-0009.

View the file

Other files for this federal contract opportunity

Other files attached to Construct VM/AGE Complex, newest first.
File Type Posted
E-701 - PANEL SCHEDULES.pdf PDF
E-702 - PANEL SCHEDULES.pdf PDF
E-703 - PANEL SCHEDULES.pdf PDF
VM_AGE RFIs Answered - Version 4.xlsx XLSX spreadsheet
E-122 - FIRST FLOOR POWER PLAN - AREA 2.pdf PDF
27 51 16 - BR.pdf PDF
10 14 00.20 - BR.pdf PDF
crouse-hinds-arktite-200a-plugs-receptacles-connectors-catalog-page.pdf PDF
08 36 19 - BR.pdf PDF
BASE MAP 24 1TO400.pdf PDF
60554859_WY-ANG_VMAF_S22 - Sheet - S-504.pdf PDF
32 13 13.06.pdf PDF
08 33 23 - BR.pdf PDF
x1806-71_cpp.pdf PDF
MS90362C.PDF PDF
Solicitation Amendment W50S8W25RA0030007 SF 30.pdf PDF
VM_AGE RFIs Answered - Version 3.xlsx XLSX spreadsheet
Solicitation Amendment W50S8W25RA0030006 SF 30.pdf PDF
20230610_060238.jpg JPG image
Jack Tester Info.PDF PDF
9000 Series.pdf PDF
1994 Asbestos Survey - B21_23_24.pdf PDF
ANG Sustainability Requirements Scoresheet.pdf PDF
20230610_060152.jpg JPG image
Solicitation Amendment W50S8W25RA0030005 SF 30.pdf PDF
VM_AGE RFIs Answered - Version 2.xlsx XLSX spreadsheet
Solicitation Amendment W50S8W25RA0030004 SF 30.pdf PDF
AECOM Drawings.zip ZIP file
Existing VM_AGE as_builts.zip ZIP file
GCFI Equipment.zip ZIP file
Geotechnical Report.zip ZIP file
TEMPLATE - H.02 Progress Schedule AF3064 (23-C-XXXX).pdf PDF
Communications UFC.zip ZIP file
Fire Spec List.zip ZIP file
Pavement Evaluations.zip ZIP file
Laydown Areas.zip ZIP file
VM_AGE Questions and Answers Version 1.xlsx XLSX spreadsheet
Solicitation Amendment W50S8W25RA0030003 SF 30.pdf PDF
Solicitation Amendment W50S8W25RA0030002 SF 30.pdf PDF
B.07 Pre-proposal Conference Site Visit Slides (25-R-A003).pptx PPTX presentation
Pre-Proposal Conference Attendance Roster.pdf PDF
Solicitation Amendment W50S8W25RA0030001 SF 30.pdf PDF
B.08 Attachment 7 - Entry Authorization Form.pdf PDF
Attachment 1 - SOW- Construct VM_AGE Complex - Aug 22 2024.pdf PDF
B.08 Attachment 7 - Entry Authorization Form.pdf PDF
Solicitation - W50S8W25RA003.pdf PDF
B.08 Attachment 4 - Contractor Hazmat Usage Tracking Instructions.pdf PDF
B.08 Attachment 5 - Past Performance Questionnaire.docx DOCX document
B.08 Attachment 8 - Wage Determination.pdf PDF
B.08 Attachment 6 - Schedule B (25-R-A003).pdf PDF
Show all 50

Construct VM/AGE Complex has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J J

J

S

J

J

J

J

J

J

J J

J J J J J

J

TOOLS/SHOP

VEHICLE MAINT

BAYS

P1 P2

E-400

H2 H1

FIRE RISER

ELEC

IT

CONF

OPEN OFFICE

TO

OFFICE

VEST

JAN

VEHICLE MAINT

WASH BAY

BREAK ROOM

TOOLS/SHOP

1 2 3 4 5 6 7

A

A.3

B

C

D

E

F

G

G

G G

G

4 4

G

G

G

G

G

G

G

G

G

G

G

GG

G

G/WP

G/WP

G/WP

G/WP

G/WP

G/WP

G

CONF

OPEN OFFICE

HALLWAY

BID OPTION 2

G/WP

G/WP

G

G

G

G

G

G

G

G

G

G

G

S3.4

P3- 1 P3- 2

P3- 2 P3- 2

P3- 2 P3- 2

G

P3- 3

P1- 4 3/4"-2#8+1#8G

P1- 4

P1- 4

P1- 4

3/4"-2#10+1#10G P1- 5

P1- 7

P1- 5 P1- 7

P1- 5

P1- 6

P1- 9

P1- 9P1- 9 P1- 9

P1- 9

P1- 6

P1- 6 P1- 6

P1- 12

P3- 22

P1- 8

P1- 8

P1- 12 P1- 12

3/4"C-2#10+1#10G P3- 4

P3- 5

P4- 3 P4- 3 P4- 2

P4- 5

P4- 14

P4- 11

P4- 12

P4- 6

P1- 4

P1- 6 G

P1- 9 G

P4- 3

P3- 6 P3- 7

P3- 7

P3- 7

P3- 6

P3- 6

P3- 8 P3- 8

P3- 8

P3- 9 P3- 9

P3- 9

P3- 10

P3- 10

P3- 10

P3- 10

P3- 11

P3- 22

P3- 11

P3- 11

P3- 11

P3- 11

P3- 12

P3- 12

P3- 12

P3- 12 P3- 12

P3- 12

P3- 13

P3- 13

P3- 13

P3- 13 3/4"-2#10,1#10G

3/4"-2#10,1#10G

P3- 11+44"

+44" +60"

P3- 22

P3- 15 P3- 16

P3- 17

P3- 18

P3- 18

P3- 18 P3- 19

P3- 19

P3- 19

P3- 20

P3- 20

P3- 20

P3- 20

P3- 21

P3- 21

P1- 11,13

P1- 23,25

P1- 15,17

P1- 19,21

P1- 27,29

P4- 13,15

3/4"-2#6+1#10G

3/4"-2#6+1#10G P4- 17,19

3/4"-2#6+1#10G

3/4"-2#6+1#10G

3/4"-2#6+1#10G

3/4"-2#6+1#10G

3/4"-2#6+1#10G

7G/WP

P3- 23

P4- 5

P4- 2

P4- 8

P4- 8

P4- 9

P4- 9

P4- 6

P4- 12

P4- 11

G

P4

P2- 25

P2- 23

REFUELER MAINT

RR-2

RR-1

P4- 7 P4- 7

P1- 8 3/4"C-2#10+1#10G

P1- 7 3/4"-2#10+1#10G

P3- 14

P4- 14

P4- 14

P3- 24

P3- 26,2810

P3

P1- 18,20

P1- 26,28

H1- 9,11,13

H1- 14,16,18

H1- 9,11,13

H1- 9,11,13 H1- 9,11,13

H1- 15,17,19

H1- 15,17,19 H1- 15,17,19

3/4"-2#10+1#10G

P4- 18

P1- 36

GP1- 30

P1- 30

P1- 32

P1- 32

P1- 32 P1- 32

P4- 27

P4- 27 P4- 27

P3- 36

PROVIDE 120V/1-PHASE

POWER FOR DOOR

CONTROL. (TYP)

1/8" = 1'-0"1

ELECTRICAL POWER PLAN - AREA 1

AREA 1 AREA 2

PARKING SHED

HEATED

PARKING

A E

C O

M T e c h n ic a l S e rv ic e s

IN

C

T o w n

C o u n tr y R o a d

O ra n g e C

A

.5

.2 w w w .a e c o m

.c o m

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B T

W Y

O M

IN

G

A

IR

N A

T

IO

N A

L G

U A

R D

C O

M B

IN

E

D V

E H

IC

L E

M A

IN

T

E N

A N

C E

A

G E

F A

C

IL

IT

Y

P R

O J

D P

E Z

PLAN

NORTH

KEY PLAN

4' 8' 16'

1/8"=1'-0SCALE:

D A

T E

E-121

F

IR

S T

F L O

O R

P O

W E

R P

L A

N

A R

E A

S C

P P

N S

B S

U B

M

IS

S

IO

N

/2

/2

W L -1

-D

-0

A. FOR ALL SPECIALITY EQUIPMENT, VERIFY

POWER REQUIREMENTS AND EXACT

LOCATIONS PRIOR TO ELECTRICAL DEVICE

ROUGH-IN.

B. COORDINATE FLOOR BOX LOCATIONS WITH

TELECOM PRIOR TO ROUGH-IN. COMBINE INTO

ONE BOX WHERE APPLICABLE.

C. 'REFUELLER MAINT 1116' SPACE IS

HAZARDOUS LOCATION CLASSIFIED AS CLASS

1 DIVISION 2. ALL ELECTRICAL DEVICES IN THIS

SPACE SHALL BE IN C1D2 RATED ENCLOSURE

WHERE REQUIRED BY NEC 501.105(B)(2),

501.115(B)(1), AND 501.150(B)(1). INSTALLATION

SHALL BE IN ACCORDANCE WITH NEC ARTICLE

501.

D. PER ANGETL 15-01-05 TABLE 6-1, ALL

ELECTRICAL EQUIPMENT, OUTLETS, CONDUIT

AND WIRING INSTALLED IN 'REFUELLER MAINT

1116' SHALL BE LOCATED WITHIN 24 INCHES OF

WALLS AND A MINIMUM OF 48-INCHES ABOVE

FINISH FLOOR.

E. ALL CONDUITS INSIDE 'REFUELLER

MAINTENACE 1116' (CLASS 1 DIVISION 2

LOCATION) SHALL BE RIGID METAL CONDUIT

(RMC) OR INTERMEDIATE METALLIC CONDUIT

(IMC) WITH LISTED FITTINGS.

F. CONDUIT CONNECTIONS TO DEVICES THAT

ARE REQUIRED TO BE C1D2 RATED SHALL BE

PROVIDED WITH CONDUIT SEALS PER NEC

501.15(b)(1). IN EACH CONDUIT RUN PASSING

FROM A CLASS 1 DIVISION 2 LOCATION INTO AN

UNCLASSIFIED LOCATION, SEAL

FITTINGS SHALL BE PROVIDED ON EITHER SIDE

AND WITHIN 10' OF THE BOUNDARY PER NEC

501.15(B)(2). ALL SEALS SHALL COMPLY WITH

NEC 501.15(C).

G. CONDUITS AND DEVICES INSTALLED IN

'VEHICLE MAIN BAYS 1115' LESS THAN 18" AFF

SHALL MEET THE REQUIRMENT OF CLASS 1

DIVISION 2 IN ACCORDANCE WITH NEC 511. ALL

ELECTRICAL DEVICES IN THESE SPACES

SHALL BE LOCATED ABOVE HAZARDOUS

RANGE (18"AFF).

KEYNOTES

1 PROVIDE POWER FOR REFRIGERATOR AS

REQUIRED. VERIFY LOCATION PRIOR TO

ROUGH IN.

2 PROVIDE POWER FOR MICROWAVE. VERIFY

LOCATION PRIOR TO ROUGH IN.

3 PROVIDE POWER FOR WATER FOUNTAIN.

VERIFY LOCATION PRIOR TO ROUGH IN.

4 PROVIDE POWER FOR PRINTER AS

REQUIRED. VERIFY LOCATION PRIOR TO

ROUGH IN.

5 PROVIDE POWER FOR WATER CLOSET

SENSORS. TRANSFORMER IS FURNISHED

WITH EQUIPMENT. VERIFY LOCATION PRIOR

TO ROUGH IN.

6 PROVIDE 6-50R RECEPTACLE.

7 PROVIDE WEATHERPOOF 6-50R

RECEPTACLE.

8 PROVIDE POWER AS REQUIRED FOR

PROJECTOR MOUNTED ON CEILING.

9 RECEPTACLES IN THIS ROOM SHALL BE

MOUNTED AT LEAST 6" ABOVE THE VIDMAR

CABINTETS. COORDINATE LOCATION IN FIELD

PRIOR TO ROUGH-IN.

10 PROVIDE POWER AS REQUIRED FOR

WASHER. VERIFY LOCATION PRIOR TO

ROUGH IN.

11 PROVIDE NEMA 14-30R RECEPTACLE FOR

DRYER. VERIFY LOCATION PRIOR TO ROUGH

IN.

12 PROVIDE POWER AS REQUIRED FOR

GARBAGE DISPOSAL AND SWITCH. VERIFY

LOCATION PRIOR TO ROUGH IN.

13 PROVIDE POWER AS REQUIRED FOR 4 POST

VEHICLE LIFT. VERIFY LOCATION PRIOR TO

ROUGH IN.

14 PROVIDE POWER AS REQUIRED FOR CRANE.

VERIFY LOCATION PRIOR TO ROUGH IN. (BID

OPTION 5)

15 PROVIDE POWER AS REQUIRED FOR ROLL UP

DOOR. VERIFY LOCATION PRIOR TO ROUGH

IN.

GENERAL NOTES:

B S

U B

M

IS

S

IO

N

F

IN

A

L

/2

/2 shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud