E-121 - FIRST FLOOR POWER PLAN - AREA 1.pdf
PDF 288 KB Posted
- Attached to
- Construct VM/AGE Complex Federal contract opportunity
- Solicitation number
- W50S8W25RA003
- Issued by
- Department of the Army National Guard
About this file
This document is an electrical power plan drawing (Sheet E-121) for the Wyoming Air National Guard's Combined Vehicle Maintenance & AGE Facility project. The detailed floor power plan for Area 1 includes specific electrical requirements for various rooms and spaces, with particular attention to specialized areas like the Refueler Maintenance space (Room 1116), which is classified as a Class 1 Division 2 hazardous location requiring specific electrical equipment and installation standards.
The drawing provides comprehensive power layout details, including receptacle placements, specialized power requirements for equipment such as vehicle lifts, cranes, roll-up doors, appliances (refrigerator, microwave, washer, dryer), and specific electrical considerations for different spaces. Notable technical specifications include requirements for electrical devices in hazardous locations, conduit installation standards, and precise mounting instructions for receptacles, with multiple keynotes detailing specific power provisions for various equipment and rooms. The document is part of a B3 Submission (100%) dated 11/22/2024, associated with Solicitation Number W9133L-16-D-0009.
View the file
Other files for this federal contract opportunity
Show all 50
Construct VM/AGE Complex has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J J
J
S
J
J
J
J
J
J
J J
J J J J J
J
TOOLS/SHOP
VEHICLE MAINT
BAYS
P1 P2
E-400
H2 H1
FIRE RISER
ELEC
IT
CONF
OPEN OFFICE
TO
OFFICE
VEST
JAN
VEHICLE MAINT
WASH BAY
BREAK ROOM
TOOLS/SHOP
1 2 3 4 5 6 7
A
A.3
B
C
D
E
F
G
G
G G
G
4 4
G
G
G
G
G
G
G
G
G
G
G
GG
G
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
G
CONF
OPEN OFFICE
HALLWAY
BID OPTION 2
G/WP
G/WP
G
G
G
G
G
G
G
G
G
G
G
S3.4
P3- 1 P3- 2
P3- 2 P3- 2
P3- 2 P3- 2
G
P3- 3
P1- 4 3/4"-2#8+1#8G
P1- 4
P1- 4
P1- 4
3/4"-2#10+1#10G P1- 5
P1- 7
P1- 5 P1- 7
P1- 5
P1- 6
P1- 9
P1- 9P1- 9 P1- 9
P1- 9
P1- 6
P1- 6 P1- 6
P1- 12
P3- 22
P1- 8
P1- 8
P1- 12 P1- 12
3/4"C-2#10+1#10G P3- 4
P3- 5
P4- 3 P4- 3 P4- 2
P4- 5
P4- 14
P4- 11
P4- 12
P4- 6
P1- 4
P1- 6 G
P1- 9 G
P4- 3
P3- 6 P3- 7
P3- 7
P3- 7
P3- 6
P3- 6
P3- 8 P3- 8
P3- 8
P3- 9 P3- 9
P3- 9
P3- 10
P3- 10
P3- 10
P3- 10
P3- 11
P3- 22
P3- 11
P3- 11
P3- 11
P3- 11
P3- 12
P3- 12
P3- 12
P3- 12 P3- 12
P3- 12
P3- 13
P3- 13
P3- 13
P3- 13 3/4"-2#10,1#10G
3/4"-2#10,1#10G
P3- 11+44"
+44" +60"
P3- 22
P3- 15 P3- 16
P3- 17
P3- 18
P3- 18
P3- 18 P3- 19
P3- 19
P3- 19
P3- 20
P3- 20
P3- 20
P3- 20
P3- 21
P3- 21
P1- 11,13
P1- 23,25
P1- 15,17
P1- 19,21
P1- 27,29
P4- 13,15
3/4"-2#6+1#10G
3/4"-2#6+1#10G P4- 17,19
3/4"-2#6+1#10G
3/4"-2#6+1#10G
3/4"-2#6+1#10G
3/4"-2#6+1#10G
3/4"-2#6+1#10G
7G/WP
P3- 23
P4- 5
P4- 2
P4- 8
P4- 8
P4- 9
P4- 9
P4- 6
P4- 12
P4- 11
G
P4
P2- 25
P2- 23
REFUELER MAINT
RR-2
RR-1
P4- 7 P4- 7
P1- 8 3/4"C-2#10+1#10G
P1- 7 3/4"-2#10+1#10G
P3- 14
P4- 14
P4- 14
P3- 24
P3- 26,2810
P3
P1- 18,20
P1- 26,28
H1- 9,11,13
H1- 14,16,18
H1- 9,11,13
H1- 9,11,13 H1- 9,11,13
H1- 15,17,19
H1- 15,17,19 H1- 15,17,19
3/4"-2#10+1#10G
P4- 18
P1- 36
GP1- 30
P1- 30
P1- 32
P1- 32
P1- 32 P1- 32
P4- 27
P4- 27 P4- 27
P3- 36
PROVIDE 120V/1-PHASE
POWER FOR DOOR
CONTROL. (TYP)
1/8" = 1'-0"1
ELECTRICAL POWER PLAN - AREA 1
AREA 1 AREA 2
PARKING SHED
HEATED
PARKING
A E
C O
M T e c h n ic a l S e rv ic e s
IN
C
T o w n
C o u n tr y R o a d
O ra n g e C
A
.5
.2 w w w .a e c o m
.c o m
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B T
W Y
O M
IN
G
A
IR
N A
T
IO
N A
L G
U A
R D
C O
M B
IN
E
D V
E H
IC
L E
M A
IN
T
E N
A N
C E
A
G E
F A
C
IL
IT
Y
P R
O J
D P
E Z
PLAN
NORTH
KEY PLAN
4' 8' 16'
1/8"=1'-0SCALE:
D A
T E
E-121
F
IR
S T
F L O
O R
P O
W E
R P
L A
N
A R
E A
S C
P P
N S
B S
U B
M
IS
S
IO
N
/2
/2
W L -1
-D
-0
A. FOR ALL SPECIALITY EQUIPMENT, VERIFY
POWER REQUIREMENTS AND EXACT
LOCATIONS PRIOR TO ELECTRICAL DEVICE
ROUGH-IN.
B. COORDINATE FLOOR BOX LOCATIONS WITH
TELECOM PRIOR TO ROUGH-IN. COMBINE INTO
ONE BOX WHERE APPLICABLE.
C. 'REFUELLER MAINT 1116' SPACE IS
HAZARDOUS LOCATION CLASSIFIED AS CLASS
1 DIVISION 2. ALL ELECTRICAL DEVICES IN THIS
SPACE SHALL BE IN C1D2 RATED ENCLOSURE
WHERE REQUIRED BY NEC 501.105(B)(2),
501.115(B)(1), AND 501.150(B)(1). INSTALLATION
SHALL BE IN ACCORDANCE WITH NEC ARTICLE
501.
D. PER ANGETL 15-01-05 TABLE 6-1, ALL
ELECTRICAL EQUIPMENT, OUTLETS, CONDUIT
AND WIRING INSTALLED IN 'REFUELLER MAINT
1116' SHALL BE LOCATED WITHIN 24 INCHES OF
WALLS AND A MINIMUM OF 48-INCHES ABOVE
FINISH FLOOR.
E. ALL CONDUITS INSIDE 'REFUELLER
MAINTENACE 1116' (CLASS 1 DIVISION 2
LOCATION) SHALL BE RIGID METAL CONDUIT
(RMC) OR INTERMEDIATE METALLIC CONDUIT
(IMC) WITH LISTED FITTINGS.
F. CONDUIT CONNECTIONS TO DEVICES THAT
ARE REQUIRED TO BE C1D2 RATED SHALL BE
PROVIDED WITH CONDUIT SEALS PER NEC
501.15(b)(1). IN EACH CONDUIT RUN PASSING
FROM A CLASS 1 DIVISION 2 LOCATION INTO AN
UNCLASSIFIED LOCATION, SEAL
FITTINGS SHALL BE PROVIDED ON EITHER SIDE
AND WITHIN 10' OF THE BOUNDARY PER NEC
501.15(B)(2). ALL SEALS SHALL COMPLY WITH
NEC 501.15(C).
G. CONDUITS AND DEVICES INSTALLED IN
'VEHICLE MAIN BAYS 1115' LESS THAN 18" AFF
SHALL MEET THE REQUIRMENT OF CLASS 1
DIVISION 2 IN ACCORDANCE WITH NEC 511. ALL
ELECTRICAL DEVICES IN THESE SPACES
SHALL BE LOCATED ABOVE HAZARDOUS
RANGE (18"AFF).
KEYNOTES
1 PROVIDE POWER FOR REFRIGERATOR AS
REQUIRED. VERIFY LOCATION PRIOR TO
ROUGH IN.
2 PROVIDE POWER FOR MICROWAVE. VERIFY
LOCATION PRIOR TO ROUGH IN.
3 PROVIDE POWER FOR WATER FOUNTAIN.
VERIFY LOCATION PRIOR TO ROUGH IN.
4 PROVIDE POWER FOR PRINTER AS
REQUIRED. VERIFY LOCATION PRIOR TO
ROUGH IN.
5 PROVIDE POWER FOR WATER CLOSET
SENSORS. TRANSFORMER IS FURNISHED
WITH EQUIPMENT. VERIFY LOCATION PRIOR
TO ROUGH IN.
6 PROVIDE 6-50R RECEPTACLE.
7 PROVIDE WEATHERPOOF 6-50R
RECEPTACLE.
8 PROVIDE POWER AS REQUIRED FOR
PROJECTOR MOUNTED ON CEILING.
9 RECEPTACLES IN THIS ROOM SHALL BE
MOUNTED AT LEAST 6" ABOVE THE VIDMAR
CABINTETS. COORDINATE LOCATION IN FIELD
PRIOR TO ROUGH-IN.
10 PROVIDE POWER AS REQUIRED FOR
WASHER. VERIFY LOCATION PRIOR TO
ROUGH IN.
11 PROVIDE NEMA 14-30R RECEPTACLE FOR
DRYER. VERIFY LOCATION PRIOR TO ROUGH
IN.
12 PROVIDE POWER AS REQUIRED FOR
GARBAGE DISPOSAL AND SWITCH. VERIFY
LOCATION PRIOR TO ROUGH IN.
13 PROVIDE POWER AS REQUIRED FOR 4 POST
VEHICLE LIFT. VERIFY LOCATION PRIOR TO
ROUGH IN.
14 PROVIDE POWER AS REQUIRED FOR CRANE.
VERIFY LOCATION PRIOR TO ROUGH IN. (BID
OPTION 5)
15 PROVIDE POWER AS REQUIRED FOR ROLL UP
DOOR. VERIFY LOCATION PRIOR TO ROUGH
IN.
GENERAL NOTES:
B S
U B
M
IS
S
IO
N
F
IN
A
L
/2
/2 shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud
File details come from the government source that posted it. Updated .