E-122 - FIRST FLOOR POWER PLAN - AREA 2.pdf
PDF 192 KB Posted
- Attached to
- Construct VM/AGE Complex Federal contract opportunity
- Solicitation number
- W50S8W25RA003
- Issued by
- Department of the Army National Guard
About this file
This document is an electrical power plan drawing (Sheet E-122) for Area 2 of a Wyoming Air National Guard Combined Vehicle Maintenance & AGE Facility project, detailing the electrical power distribution and receptacle layout. The drawing includes multiple keynotes specifying precise electrical requirements, such as providing various specialized receptacles for equipment including generator connections (MS90362 connector), crane power, roll-up door power, and receptacles for specific tools like drill presses and jack testers. The plan covers power specifications for different voltage and amperage requirements, with annotations indicating conduit sizes, receptacle types, and installation guidelines, including special considerations for Class 1 Division 2 locations and hazardous area electrical installations. The drawing is part of a B3 submission (100% final) dated 11/22/2024, associated with solicitation number W9133L-16-D-0009, and prepared by AECOM Technical Services for the Wyoming Air National Guard facility project.
View the file
Other files for this federal contract opportunity
Show all 50
Construct VM/AGE Complex has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J J
J J
P2
H2
AGE BAYS
JACK TESTER
7 7.4 8 9 10 11
A
A.3
B
C
D
E
F
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
G/WP
COLD STORAGE
BID OPTION 1
G
G
G
G
G
G G G
G
G
G
G
G
G
G G
G
P2- 11
P2- 16,18
P2- 13,15
P2- 12 3/4"C-2#10+1#10G
P2- 14 3/4"C-2#10+1#10G
P2- 17 3/4"C-2#10+1#10G
DP- 6P2- 20,22,24
1"C-3#6+1#10G
MSB- 8
MSB- 7
P2- 19
P2- 19 P2- 19
P2- 19
H2- 1,3,5
P2- 7 P2- 9
P2- 10
P2- 8
P2- 7
P2- 9
P2- 10P2- 7 P2- 9
P2- 36
P2- 25
P2- 25
P2- 28 P2- 28
P2- 27
P2- 27
P2- 30
P2- 30
P2- 29
P2- 29P2- 32 P2- 32
P2- 31
P2- 31
P2- 34
P2- 34
MSB- 9
P2- 21
P2- 23
P2- 26
P2- 48
P2- 44
P2- 46
3/4"C-2#10+1#10G
1 1/4"C-3#1+1#8G
P2- 7
P2- 8
P2- 9
P2- 10
P2- 8
P2- 8
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
P2- 1 3/4"C-2#8+1#8G
P2- 2 3/4"C-2#8+1#8G
P2- 3 3/4"C-2#8+1#8G
P2- 4
3/4"C-2#8+1#8G
P2- 5 3/4"C-2#8+1#8G
P2- 6 3/4"C-2#8+1#8G
3/4"C-2#10+1#10G
WPWP
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
3/4"C-2#10+1#10G
G/WP
P2- 19
100A
H2- 7,9,11
H2- 13,15,17
H2- 6,8,10
H2- 6,8,10
H2- 6,8,10
H2- 7,9,11 H2- 7,9,11
P2- 42
P2- 42
P2- 52
P2- 52
PROVIDE 120V/1-PHASE
POWER FOR DOOR
CONTROL. (TYP)
1/8" = 1'-0"1
ELECTRICAL POWER PLAN - AREA 2
AREA 1 AREA 2
PARKING SHED
HEATED
PARKING
A E
C O
M T e c h n ic a l S e rv ic e s
IN
C
T o w n
C o u n tr y R o a d
O ra n g e C
A
.5
.2 w w w .a e c o m
.c o m
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B T
W Y
O M
IN
G
A
IR
N A
T
IO
N A
L G
U A
R D
C O
M B
IN
E
D V
E H
IC
L E
M A
IN
T
E N
A N
C E
A
G E
F A
C
IL
IT
Y
P R
O J
D P
E Z
PLAN
NORTH
KEY PLAN
4' 8' 16'
1/8"=1'-0SCALE:
D A
T E
E-122
E L E
C T
R
IC
A L P
O W
E R
P L A
N
A R
E A
S C
P P
N S
B S
U B
M
IS
S
IO
N
/2
/2
W L -1
-D
-0
A. ALL RECEPTACLES SHALL BE LABELED WITH
THE PANEL AND CIRCUIT NUMBER THAT IT IS
FED FROM.
B. FOR ALL SPECIALITY EQUIPMENT, VERIFY
POWER REQUIREMENTS AND EXACT
LOCATIONS PRIOR TO ELECTRICAL DEVICE
ROUGH-IN.
C. COORDINATE FLOOR BOX LOCATIONS WITH
TELECOM PRIOR TO ROUGH-IN. COMBINE
INTO ONE BOX WHERE APPLICABLE.
D. CONDUIT CONNECTIONS TO DEVICES THAT
ARE REQUIRED TO BE C1D2 RATED SHALL BE
PROVIDED WITH CONDUIT SEALS PER NEC
501.15(B)(1). IN EACH CONDUIT RUN PASSING
FROM A CLASS 1 DIVISION 2 LOCATION INTO
AN UNCLASSIFIED LOCATION, SEAL
FITTINGS SHALL BE PROVIDED ON EITHER
SIDE AND WITHIN 10' OF THE BOUNDARY PER
NEC 501.15(B)(2). ALL SEALS SHALL COMPLY
WITH NEC 501.15(C).
E. CONDUITS AND DEVICES INSTALLED IN 'AGE
BAYS 1122' AND 'JACK TESTER 1121' ROOMS
LESS THAN 18" AFF SHALL MEET THE
REQUIRMENT OF CLASS 1 DIVISION 2 IN
ACCORDANCE WITH NEC 511. ALL
ELECTRICAL DEVICES IN THESE SPACES
SHALL BE LOCATED ABOVE HAZARDOUS
RANGE (18"AFF).
KEYNOTES
1 PROVIDE CS6364, 50A, 250V, 3P, 4W
RECEPTACLE W/ 60A NON-FUSIBLE
DISCONNECT.
2 PROVIDE L5-30R RECEPTACLE.
3 PROVIDE MS27265 RECEPTACLE TYPE, 180A,
480V, 3P, 4W W/ 200A NON-FUSIBLE
DISCONNECT SWITCH. REFER TO SINGLE
LINE DIAGRAM FOR CONDUCTOR AND
CONDUIT SIZES. PROVIDE WITH DEAD-MAN
CIRCUIT INTERLOCK/CONTROL AND ALL
REQUISITE ACCESSORIES AND
APPURTENANCES.
4 PROVIDE 5-15R OVERHEAD CORD REEL.
COORDINATE LOCATION IN
5 PROVIDE MS90362 CONNECTOR WITH 120V,
400Hz 3PH LEAD FOR GENERATOR
CONNECTION ON THE BUILDING EXTERIOR.
PROVIDE (4)#1/0 AND (2)#12 WIRES TO THE
CONNECTOR.
6 PROVIDE 6-15R RECEPTACLE FOR DRILL
PRESS.
7 PROVIDE POWER AS REQUIRED FOR TRIPOD
JACK TESTER.
8 PROVIDE POWER AS REQUIRED FOR
SCISSOR LIFT.
9 PROVIDE POWER AS REQUIRED FOR
FREQUENCY CONVERTER. COORDINATE
LOCATION IN FEILD PRIOR TO ROUGH-IN.
10 PROVIDE ARKTITE TYPE AR2042, 200A, 208V,
3P, 4W RECEPTACLE W/ 200A NON-FUSIBLE
DISCONNECT. REFER TO SINGLE LINE
DIAGRAM FOR CONDUCTOR AND CONDUIT
SIZES.
11 PROVIDE POWER AS REQUIRED FOR CRANE.
VERIFY LOCATION PRIOR TO ROUGH IN. (BID
OPTION 6)
12 PROVIDE POWER AS REQUIRED FOR ROLL
UP DOOR. VERIFY LOCATION PRIOR TO
ROUGH IN.
GENERAL NOTES:
B S
U B
M
IS
S
IO
N
F
IN
A
L
/2
/2 shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud shea.culbertson Cloud
File details come from the government source that posted it. Updated .