About this file
This document includes a Request for Information and response regarding a federal solicitation for construction of a new fire station. The solicitation seeks to replace an existing fire station at Mansfield Air National Guard Base in Mansfield, Ohio. The new station must comply with emergency response time standards and include space for emergency management training. The construction period is estimated at 660 calendar days. Optional items that may be included are concrete paving, apparatus doors, and a bridge crane. Bids will be evaluated without discussions and awarded in accordance with FAR procedures. The project is set aside for small businesses with a NAICS code of 236220 and size standard of $39.5 million average annual revenue. The pre-bid conference is November 5, 2019 and bids are due November 26, 2019. Questions should be directed to the specified contracting officer.
RFI 03
View the file
Other files for this federal contract opportunity
Show all 50
REPLACE FIRE STATION has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION
R
EQ
U
ESTO
R
SEC
TIO
N
From: Date:
To:
1. Solicitation Number:
W50S8R-20-B-0001
2. Location of Project:
Fire Station - Mansfield Ohio ANG
3. Information Requested: (Include Specification Section and/or Drawing Number and Page if inquiring about a discrepancy)
Per Drawing “P602”, ”Plumbing Equipment Schedule”, Mark “OWS-1”, the description states, “PRECAST OR FIBERGLASS OIL / WATER SEPERATOR.”
Request that polyethylene construction be approved for this interceptor.
We represent Striem and they use polyethylene to manufacturer their interceptors. I have attached a specification sheet for your review and approval.
Attachments: Date Response Required:
By: Title:
Requestor's FAX Number: Requestor's Telephone Number:
mailto:devans@rcfrey.com mailto:devans@rcfrey.com
R
ESPO
N
SE
To:
Contracting Officer
Date:
October 30, 2019
Response:
Acceptable materials of construction are precast concrete, carbon steel, reinforced fiberglass, or reinforced glass fiber resin laminates over rigid urethane foam core. Polyethylene OWS is not acceptable.