RFI_12.pdf

PDF 86 KB Posted

Attached to
REPLACE FIRE STATION Federal contract opportunity
Solicitation number
W50S8R-20-B-0001
Issued by
Department of the Army Ohio Army National Guard

About this file

This document provides details for a federal contract solicitation to replace a fire station. The solicitation number is W50S8R-20-B-0001 and is issued by the USPFO for Ohio Purchasing and Contracting Office for the Mansfield Air National Guard Base. The project scope includes construction of a new aircraft rescue and firefighting facility along with emergency management training space. The pre-bid conference is scheduled for November 5th and bids are due November 26th. The contract duration is estimated at 660 calendar days. The solicitation includes options for additional concrete paving and equipment. The NAICS code is 236220 with a $39.5 million size standard. The project value is estimated between $10-20 million. The solicitation and plans are available through the Federal Business Opportunities website.

View the file

Other files for this federal contract opportunity

Other files attached to REPLACE FIRE STATION, newest first.
File Type Posted
Abstract_FIRE_pg3.pdf PDF
RFI_20.pdf PDF
RFI_21.pdf PDF
RFI_21_attachment.pdf PDF
RFI_17.pdf PDF
A-601 - DOOR-WINDOW SCHEDULES.pdf PDF
RFI_15.pdf PDF
RFI_19.pdf PDF
RFI_07 attach.pdf PDF
RFI_08 attach.pdf PDF
RFI_08.pdf PDF
RFI_07.pdf PDF
RFI_09.pdf PDF
RFI_10_attachment.pdf PDF
RFI_10.pdf PDF
RFI_11.pdf PDF
Pre-Bid_minutes,_data.pdf PDF
RFI_4.pdf PDF
RFI_3.pdf PDF
Attach2_Vol_2_Specifications.pdf PDF
Attach6_General.pdf PDF
Attach6_Electrical.pdf PDF
Attach6_Fire_Alarm.pdf PDF
Attach6_Civil_4a.pdf PDF
Attach6_Civil_4b.pdf PDF
Attach6_Structural.pdf PDF
Attach6_Civil_3.pdf PDF
Attach7_Geotechnical_Report.pdf PDF
Attach6_Civil_6a.pdf PDF
Attach6_Civil_8a.pdf PDF
Attach6_Civil_5d.pdf PDF
Attach6_Civil_9.pdf PDF
Attach6_Civil_8b.pdf PDF
Attach6_Telecommunications.pdf PDF
Attach6_Architectural.pdf PDF
Attach6_Civil_6b.pdf PDF
Attach6_Civil_7.pdf PDF
Attach6_Civil_4c.pdf PDF
Attach6_Civil_5b.pdf PDF
Attach6_Plumbing.pdf PDF
Attach6_Mechanical.pdf PDF
Attach4_Vol_4_Specifications.pdf PDF
Attach1_Vol_1_BOD.pdf PDF
Attach8_RFI_template.doc DOC document
Attach6_Civil_1b.pdf PDF
Attach6_Civil_1a.pdf PDF
EXHIBIT_A-Communications_Equipment.xlsx XLSX spreadsheet
EXHIBIT_B_Sealed_Bid_Reminders.pdf PDF
Attach3_Vol_3_Specifications.pdf PDF
Attach5_Vol_5_Specifications.pdf PDF
Show all 50

REPLACE FIRE STATION has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION

R E

Q U

E S

T O

R S

E C

T

IO

N

From:

Date:

11.15.2019

To: Contracting Officer

1. Solicitation Number:

W50S8R-20-B-0001

2. Location of Project:

Fire Station - Mansfield Ohio ANG

3. Information Requested: (Include Specification Section and/or Drawing Number and Page if inquiring about a discrepancy)

Requesting clarification on the design documents. The concrete specifications call out the use of micro & macro fiber reinforcement. However, the structural drawings are calling out for rebar reinforcement in you slabs.

Are you going to allow the substitution of macro fiber for the rebar in those slabs?

Attachments:

Date Response Required:

By:

Title:

Requestor's FAX Number:

Requestor's Telephone Number:

R E

S P

O N

S E

To:

Date:

Response:

Reinforcing required as shown. Fiber reinforcement is for crack control and is in addition to rebar.

This information is a clarification of the solicitation/contract and does not change the contract terms or conditions.