This document includes a request for information and federal contract opportunity notice. The request for information seeks clarification on carpet tile specifications, ceramic tile sizes and locations, carpet installation methods, threshold types, and room finish schedules for a fire station replacement project at Mansfield Air National Guard Base in Ohio. The related federal contract opportunity is a solicitation notice for the fire station replacement project, with an estimated construction duration of 660 calendar days and budget between $10-20 million. Optional bid items include concrete paving, apparatus doors, and a bridge crane. Bids are set aside for small businesses and will be evaluated without discussions. The pre-bid conference is scheduled for November 5th and bids are due November 26th. Interested parties must register on SAM.gov and check the FedBizOpps website for solicitation documents and any amendments.
View the file
Other files for this federal contract opportunity
Show all 50
REPLACE FIRE STATION has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION
R E
Q U
E S
T O
R S
E C
T
IO
N
From:
Date:
11/15/19
To: Contracting Officer
Gordon Strom
1. Solicitation Number:
W50S8R-20-B-0001
2. Location of Project:
Fire Station - Mansfield Ohio ANG
3. Information Requested: (Include Specification Section and/or Drawing Number and Page if inquiring about a discrepancy)
1) For the area with the Rigid Grid Access Flooring: It calls for carpet tiles to be installed ¼ turned atop of the panels. I do not believe that Patcraft carpet has any static dissipative properties! In the specs, it says the “anti-static agent must be an integral part of the material, not surface applied” Is there different carpet going in that area? If not, is there a manufacturing process that Patcraft would adhere to so that the carpet tiles have anti-static properties?
2) The only areas I see calling for tile are:
-123 Jan. Closet -125 Men’s -126 Women’s -141 Unisex -225 Men’s -226 Women’s I’m assuming F-5 is what the Room Finish Schedule is calling CT-1 but it’s very confusing. I still need a size for that material.
It is extremely unclear what the wall tile is supposed to be. It just says CT on the Room Finish Schedule. There is nothing shown on the Elevations for any of the restrooms or other areas except for Rm 141 and Rm 116. On the Interior Color Schedule, under the comments, it says “field color, janitors closet” for W-1 and W-2 says “accent color in restrooms” under the comments. But, no elevations are shown on the prints so I don’t have any way to see where the accent color is supposed to go. I also do not know the size of that material! I need more information about the ceramic. .
3) In the specs it calls for an “adhesive tab system for carpet installation”. Does this mean they do NOT want traditional adhesive used and prefer the tac-tile tabs everywhere we would be installing carpet tiles?
4) What are we using at all of the thresholds of the doorways? Many of them show a threshold the width and thickness of the doorway on the prints, but not all do.
5) The room schedule and Specs do not match, plans call for CT-1 and CT-2 but there is no CT-1 and CT2 on the finish schedule. Please confirm the materials to be used on this project.
6) The Tarkett, replay commotion rubber tiles for F6 are supposed to be interlocking or square edge tiles?
Attachments:
Date Response Required:
By:
Title:
Requestor's FAX Number:
Requestor's Telephone Number:
R E
S P
O N
S E
To:
Date:
Response:
1) Carpet tiles are not required to have anti-static properties.
2) See revised room finish/color schedule (attachment “A-602-Interior Finish-Color Schedule”).
3) Adhesive tab system for carpet installation shall be used. Tac-tile tabs shall be used everywhere carpet tiles shall be installed
4) Saddle thresholds shall be used.
5) See revised room finish/color schedule (attachment “A-602-Interior Finish-Color Schedule”).
6) The commotion rubber tiles shall be interlocking.
This information is a clarification of the solicitation/contract and does not change the contract terms or conditions.