ATTACHMENT 22-DRAWINGS-SAT-VOL 3 OF 4 Fire Protection Plumbing Mechanical 36 pages.pdf
PDF 9 MB Posted
- Solicitation number
- W50S87-21-B-5005
About this file
This solicitation is for the 145 Airlift Wing Addition/Alteration to the Small Air Terminal Building 5 project. Key details include the requirement to add and alter an existing small air terminal to support C-17 aircraft operations. The pre-bid conference will be held on June 2, 2021 and bids are due by June 18, 2021. The project involves the North Carolina Army National Guard and is funded by the Department of the Army. Construction is to be completed by January 2023.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C- 17A Globe m aster I II
C-17A Globemaster III
C-1 7A
Globe m as ter I
II
C-17A Globe m aster III
C- 17A Globe m aster I II
C-
A Globe m as ter
III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II
C-
A Globe m as ter
III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II
C-17A Globemaster III C- 17A Globe m aster I II
C-17A Globemaster III
C-17A Globemaster III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II rwall rwall walltank rwall
A I R P O R T D R I V E
HE
RC
UL
ES
Av e rwall rw al l rwall wall tank tank wall
PRIVATE ROAD
SABER DRIVE
BRICK SCR EEN WALL
C O N C.
RE
T AI N
I N G W A
L L
Payne Blvd
Hercules Ave
E n l i st e d
Dr i v e
H e r c ul es A v e
Stair s wall tank tank
Payne Avenue
MORRIS FIELD DRIVE
T
SOUTH ECP
S A
BE
R
DR
IV
E
PROJECT LOCATION
AIR DROP AND BUILDING 5
North Carolina Air National Guard
COMBINED PACKAGE
Charlotte, North Carolina
ISSUE FOR BIDS - MARCH 3, 2021
2000 East Lamar Boulevard, Suite 600 Arlington, Texas 76006
Telephone: 817.588.3010 www.fsb-ae.com
Frankfurt Short Bruza / Texas Architecture Engineering Planning Interior Design
C-17 Conversion: Air Drop Facility Project Number FJRP199040
C-17 Conversion: Small Terminal Project Number FJRP052994
C
-1
AD
AL
A ir
D ro p Fa c
SCALE: 1" = 30'-0"
PROJECT LOCATION1
N
0 30' 60'
THE TWO PROJECTS ISSUED FOR BID UNDER
THIS COVER SHALL BE PRICED INDEPENDENTLY
AS INDICATED ON THE BID SHEETS ISSUED BY
THE NORTH CAROLINA AIR NATIONAL GUARD.
THAT SHALL INCLUDE ANY CHANGES ISSUED
SUBSEQUENTLY DURING THE BIDDING OR
CONSTRUCTION PHASES.
THE LIMITS OF THE WORK FOR PRICING
PURPOSES IS INDICATED WITH EACH PROJECT
SET OF DRAWINGS. HOWEVER, THE WORK SHALL
BE SCHEDULED, PERFORMED AND
COORDINATED AS THOUGH IT WERE A SINGLE
SET OF CONSTRUCTION DOCUMENTS.
050024
C- 17A Globe m aster I II
C-17A Globemaster III
C-1 7A
Globe m as ter I
II
C-17A Globe m aster III
C- 17A Globe m aster I II
C-
A Globe m as ter
III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II
C-
A Globe m as ter
III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II
C-17A Globemaster III C- 17A Globe m aster I II
C-17A Globemaster III
C-17A Globemaster III
C- 17A Globe m aster I II
C-17A Globemaster III
C- 17A Globe m aster I II rwall rwall walltank rwall
A I R P O R T D R I V E
HE
RC
UL
ES
Av e rwall rw al l rwall wall tank tank wall
PRIVATE ROAD
SABER DRIVE
BRICK SCR EEN WALL
C O N C.
RE
T AI N
I N G W A
L L
Payne Blvd
Hercules Ave
E n l i st e d
Dr i v e
H e r c ul es A v e
Stair s wall tank tank
Payne Avenue
MORRIS FIELD DRIVE
T
SOUTH ECP
S A
BE
R
DR
IV
E
PROJECT LOCATION
North Carolina Air National Guard C-17 Conversion Add/Alter Small Air Terminal - Building 5
Charlotte, North Carolina Project Number: FJRP 052994
ISSUE FOR BIDS - MARCH 03, 2021
2000 East Lamar Boulevard, Suite 600 Arlington, Texas 76006
Telephone: 817.588.3010 www.fsb-ae.com
Frankfurt Short Bruza / Texas Architecture Engineering Planning Interior Design
NORTH CAROLINA CERTIFICATE
OF AUTHORIZATION
ARCHITECTURE: # 53655
EXP: 12/31/2021
NORTH CAROLINA CERTIFICATE
OF AUTHORIZATION
PE: # C-4735
EXP: 06/30/2021
SCALE 1" = 30'-0"
PROJECT LOCATION1
SHEET INDEX
NUMBER TITLE
PLUMBING
P-001 LEGEND & ABBREVIATIONS
PD101 PLUMBING DEMOLITION - UNDERFLOOR & FIRST
FLOOR
PD102 PLUMBING DEMOLITION - SECOND FLOOR &
ROOF
P-101 UNDERFLOOR PLUMBING
P-102 GROUND FLOOR PLUMBING
P-103 SECOND FLOOR PLUMBING
P-104 ROOF PLUMBING
P-501 PLUMBING DETAILS
P-601 DOMESTIC WATER RISER
P-602 WASTE AND VENT RISER
P-701 PLUMBING SCHEDULES
MECHANICAL
M-001 LEGEND & ABBREVIATIONS
MD101 GROUND FLOOR MECHANICAL DEMOLITION
PLAN
MD102 SECOND FLOOR MECHANICAL DEMOLITION
PLAN
MD103 ROOF MECHANICAL DEMOLITION PLAN
MH101 GROUND FLOOR MECHANICAL HVAC PLAN
MH102 SECOND FLOOR MECHANICAL HVAC PLAN
MH103 ROOF MECHANICAL HVAC PLAN
MP101 GROUND FLOOR MECHANICAL PIPING PLAN
MP102 SECOND FLOOR MECHANICAL PIPING PLAN
M-301 SECTIONS
M-401 ENLARGED PLANS
M-501 DETAILS
M-601 FLOW DIAGRAMS
M-701 MECHANICAL SCHEDULES
M-702 MECHANICAL SCHEDULES
M-801 MECHANICAL CONTROLS
M-802 MECHANICAL CONTROLS
ELECTRICAL
E-001 LEGEND, ABBREVIATIONS & MOUNTING HEIGHT
DETAIL
ES101 ELECTRICAL SITE LIGHTING PLAN
ES102 ELECTRICAL SITE PLAN
ED101 GROUND FLOOR ELECTRICAL DEMOLITION
PLAN
ED102 SECOND FLOOR ELECTRICAL DEMOLITION
PLAN
EG101 GROUNDING PLAN & GROUNDING SYSTEM
DIAGRAM
EG102 LIGHTNING PROTECTION PLAN
EG500 GROUNDING & LIGHTNING PROTECTION
DETAILS
EG501 GROUNDING & LIGHTNING PROTECTION
DETAILS
EP101 GROUND FLOOR POWER PLAN
EP102 SECOND FLOOR POWER PLAN
EP103 ROOF POWER PLAN
EP104 GROUND FLOOR MECHANICAL POWER PLAN
EP105 SECOND FLOOR MECHANICAL POWER PLAN
EP600 ONE-LINE DIAGRAM, FEEDER SCHEDULE &
MECHANICAL EQUIPMENT SCHEDULE
EP700 PANEL SCHEDULES
EP701 PANEL SCHEDULES
EL101 GROUND FLOOR LIGHTING PLAN
EL102 SECOND FLOOR LIGHTING PLAN
EL501 LIGHTING DETAILS
EL700 LIGHTING SCHEDULES
EY101 ELECTRICAL INTERIOR AUXILIARY SYSTEMS
EY101-PA ELECTRICAL SPECIAL SYSTEMS PUBLIC
ADDRESS
EY102 SECOND FLOOR SPECIAL SYSTEMS PLAN
EY501 SPECIAL SYSTEMS DETAILS
EY601 SPECIAL SYSTEMS RISER DIAGRAMS
ET101 GROUND FLOOR TELECOMMUNICATION PLAN
ET102 SECOND FLOOR TELECOMMUNICATION PLAN
ET501 TELECOM DETAILS
ET601 DIGITAL CLOCK RISER DIAGRAM
ET602 TELECOM RISER DIAGRAM
SHEET INDEX
NUMBER TITLE
GENERAL
G-001 COVER SHEET, SHEET INDEX & VICINITY PLAN
G-101 CODE AND LIFE SAFETY PLAN
G-102 APPENDIX B CODE SHEETS
CIVIL
C100 EXISTING CONDITIONS PLAN
C101 DEMOLITION PLAN
C102 SITE PLAN
C110 UTILITY PLAN
C111 TEMPORARY UTILITY PLAN
C112 EXTERIOR STAIRWAY PLAN
C501 CONSTRUCTION DETAILS
C502 CONSTRUCTION DETAILS
LANDSCAPE
LS100 LANDSCAPE SITE PLAN
LS400 ENLARGED LAYOUT PLANS
LP100 LANDSCAPE PLANTING PLAN
LP500 PLANTING DETAILS / PLANTING SCHEDULE
STRUCTURAL
S-001 GENERAL NOTES
S-002 TYPICAL DETAILS
SB101 FOUNDATION PLAN
SB301 FOUNDATION DETAILS
SB501 FOUNDATION DETAILS
SF101 SECOND FLOOR FRAMING PLAN
SF102 HIGH ROOF FRAMING PLAN
SF201 FRAMING ELEVATIONS
SF202 FRAMING ELEVATIONS
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
ARCHITECTURE
A-001 ABBREVIATIONS, ACCESSIBILITY, PARTITIONS &
SYMBOLS
AD101 DEMOLITION PLANS
AD102 DEMOLITION ROOF PLAN
AE101 GROUND FLOOR PLAN
AE102 SECOND FLOOR PLAN
AE103 REFLECTED CEILING PLANS
AE104 REFLECTED CEILING DETAILS
AE105 ROOF PLAN
AE201 BUILDING ELEVATIONS
AE301 BUILDING SECTIONS
AE310 WALL SECTIONS
AE311 WALL SECTIONS
AE401 ENLARGED PLANS AND INTERIOR ELEVATIONS
AE402 ENLARGED PLANS AND INTERIOR ELEVATIONS
AE403 ENLARGED PLANS AND INTERIOR ELEVATIONS
AE404 INTERIOR ELEVATIONS
AE405 ENLARGED STAIR PLANS & SECTION
AE406 ENLARGED STAIR PLANS & ELEVATIONS
AE407 ENLARGED ELEVATOR PLANS & DETAILS
AE408 ENLARGED EXTERIOR STAIRS
AE501 PLAN DETAILS
AE601 DOOR SCHEDULE AND DETAILS
AE602 DOOR DETAILS
AE603 GLAZING DETAILS
AE604 ROOM FINISH SCHEDULE
AG101 GROUND FLOOR SIGNAGE PLAN
AG102 SECOND FLOOR SIGNAGE PLAN
AG103 SIGNAGE DETAILS
AG104 SIGNAGE DETAILS & SCHEDULE
INTERIORS
IF101 GROUND FLOOR FURNITURE PLAN
IF102 SECOND FLOOR FURNITURE PLAN
FIRE PROTECTION
FP001 FIRE PROTECTION, LEGEND, ABBREVIATIONS,
AND PIPING SCHEMATIC
FP101 GROUND FLOOR FIRE PROTECTION PLAN
FP102 SECOND FLOOR FIRE PROTECTION PLAN
FP401 FIRE PROTECTION ENLARGED PLANS AND
SECTIONS
FP501 FIRE ALARM & MASS NOTIFICATION RISER
DIAGRAM
FP601 FIRE ALARM & MASS NOTIFICATION
INPUT/OUTPUT MATRIX
SEAL
050568
ENGINEE
R
Frankfurt-Short-Bruza Architects Engineers Planners
11949
VOLUME 3 OF 4
ABBREVIATIONS
............................................................ ABOVE
....................................... ADMINISTRATIVE
.............................. ABOVE FINISHED FLOOR
...................................................... BUILDING
............................... BACKFLOW PREVENTER
....................... CONTINUE, CONTINUATION
............................................... DEPARTMENT
........................................ DETECTOR, DETAIL
.................................................... DUCTILE IRON
................................................. DISCHARGE
................................................. EXTRA HAZARD
................................................. EQUIPMENT
....................................................... FIRE ALARM
FACU
.............. FIRE DEPARTMENT CONNECTION
...................... FIRE PROTECTION, FIRE PUMP
....................................................... FOOT, FEET
................ INSPECTOR'S TEST CONNECTION
..................................................... JOCKEY PUMP
.................................................... LIGHT HAZARD
................................................. MECHANICAL
........................................ NORMALLY CLOSED
........................... OUTSIDE STEM AND YOKE
................................. POST INDICATING VALVE
........................................... ORDINARY HAZARD
................................................... PRESSURE
........................... POUNDS PER SQUARE INCH
....................................... REFERENCE, REFER
..................... RELEASING SYSTEM FSCP
.................................................... SQUARE FOOT
.................................................. SOUNDER BASE
................................. GALLONS PER MINUTE
............................................................. TYPICAL
.............................................. TEMPERATURE
.................................... UNDERGROUND
............................ WET PIPE, WEATHERPROOF
..................................................................... WITH
........................................................... WITHOUT
........................................................... HAZARD
.................................................. HYDRAULIC
............................................... NOT APPLICABLE
................................................................ EQUAL
......................... FIRE ALARM ANNUNCIATOR
...................... MASS NOTIFICATION SYSTEM
................................................. NOT TO SCALE
................................................................ SHEET
........................ UNLESS NOTED OTHERWISE
.......................................................... CANDELA
................................................................ FLOOR
........................ HIGH VOLUME LOW SPEED
................ AQUEOUS FILM-FORMING FOAM
.......................................... FIRE DEPARTMENT
.............. FOAM SYSTEM CONTROL PANEL
..................................................... TRANSMIT
............................................................. SYSTEM
................................................................. PUMP
................................................ SUPERVISORY
............................................................ STATION
.............................................. AUTOMATION
............ ENHANCED DISCREET I/O MODULE
.............................................. INPUT / OUTPUT
................................................... SUPERVISION
........................................................ SCHEDULE
................. SEISMIC SEPARATION ASSEMBLY
ABV
ADMIN
AFF
BLDG
BFP
.......................... CONNECT, CONNECTION
CONT
DEPT
DET
DI
DISCH
EH
EQUIP
FA
...................... FIRE ALARM CONTROL UNIT
FDC
FP
FT
ITC
JP
LH
MECH
N.C.
OS&Y
PIV
OH
PRESS
PSI
REF
RSFACU
SF
SB
GPM
TYP
TEMP
UGND, UG
WP
W/ W/O
HAZ
HYDR
NA
EQ
FAA
MNS
NTS
SHT
UNO
CD
FL
HVLS
AFFF
FD
FSCP
TRANS
SYS
PMP
SUPV
STA
AUTO
EDIO
I / O
........................................ CARBON MONOXIDE
SUP
SCH
SSA
CONN
CO
LOC...........................LOCAL OPERATING CONSOLE
WET PIPE SPRINKLER SUPPLY
SYMBOL
FIRE ALARM MANUAL PULL STATION
WALL MOUNTED FIRE ALARM/MNS
SPEAKER/STROBE, XX INDICATES CD
RATING
CEILING MOUNTED FIRE ALARM SPEAKER
CEILING MOUNTED FIRE ALARM/MNS
SPEAKER/STROBE, XX INDICATES CD
RATING
FIRE DEPARTMENT CONNECTION
WALL MOUNTED FIRE ALARM/MNS
SPEAKER
ANGLE VALVE
CHECK VALVE
CONTROL VALVE
FPW
FP
XX
CEILING MOUNTED FIRE ALARM/MNS
STROBE, XX INDICATES CD RATING
WATERFLOW ALARM SPEAKER / STROBE.
XX INDICATES CANDELA RATING
F
C
XX
P
S C
XX
S
C
WP
XX
DESCRIPTION SYMBOL DESCRIPTION
FIRE PROTECTION LEGEND
FIRE PROTECTION PIPING
SMOKE DETECTOR - PHOTOELECTRIC
DUCT SMOKE DETECTOR; XX INDICATES
ASSOCIATED UNIT
TRANSCEIVER ANTENNA
FAPX POWER EXTENDER PANEL
FAA FIRE ALARM ANNUNCIATOR
FACU
FIRE ALARM & MASS NOTIFICATION
CONTROL UNIT
LOC LOCAL OPERATING CONSOLE
SPD SURGE PROTECTION DEVICE
K
DUCT SMOKE DETECTOR KEYED REMOTE
TEST STATION
AIM ADDRESSABLE INPUT MODULE
AOM ADDRESSABLE OUTPUT MODULE
OPEN FUNNEL DRAIN
POST INDICATING VALVE
RISER CHECK VALVE
INSPECTORS TEST CONNECTION (WITH
PRESSURE RELIEF)
PRESSURE GAUGEPI
PIPE OR CONDUIT BREAK / CONTINUATION
WATERFLOW SWITCH (VANE TYPE)WF
VALVE SUPERVISORY SWITCHVS
SYMBOL DESCRIPTION
DIGITAL ALARM COMMUNICATOR
TRANSMITTERDACT
DOOR HOLDER-WALL MOUNTED W-TAGDH
END OF LINE RESISTOREOL
FLOW METERM
FREE STANDING SIAMESE FDC
AIRFLOW ARROW
PIPE FLOW ARROW
HEAT DETECTOR-CEILING MOUNTED WITH
TEMPERATUREXX°
INSULATING FLANGE & GASKET KIT
PIPE CONTINUATION
REDUCER TRANSITION
WALL MOUNTED FIRE ALARM/MNS STROBE,
XX INDICATED CD RATING
PIPE BALL DRIP
PIPE CAP
OS&Y GATE VALVE
VS
XX
HYDRONIC FLOW ARROW
P
ELEVATOR LOBBY SMOKE DETECTOR -
PHOTOELECTRICL
ET TEXTUAL VISUAL APPLIANCE
PULL DOWN
FIRE ALARM
I R E
F
" M
IN
" M
IN
NOTES:
A. VERIFY EXACT MOUNTING
HEIGHTS WITH PROJECT
REQUIREMENTS. DEVICES MAY
OR MAY NOT APPLY TO THIS
PROJECT. REFER TO PLANS.
B. ALL NEW DEVICES SHALL BE
INSTALLED ACCORDING TO THE
MOUNTING HEIGHTS INDICATED
U.N.O.
AUDIBLE/VISUAL
UNIT
VISUAL
ONLY UNIT
MANUAL PULL
STATION
TOP OF
PULL
STATION
HANDLE
FINISHED FLOOR
I R E
F
I R E
F
AUDIBLE
ONLY UNIT
TEXT SIGN
0"
M A
X.
FDC
PUMP TEST
HEADER ONE (1) 2.5"
HOSE
FROM FDC
PUMP TEST
HEADER
FLOW
METER
VS
FIRE
PUMP
VS VS
JOCKEY
PUMP
6" FP SUPPLY
REFER TO SHEET
C110 FOR CONT.
FP
WP-1
VS
V S
V S
DOUBLE DETECTOR
CHECK VALVE
BACKFLOW PREVENTER
WF
PIPE MAIN DRAIN TO EXTERIOR
OF BUILDING TO A CONCRETE
SPLASH BLOCK OR PAVEMENT
OS&Y VALVE W/TAMPER
SWITCH (TYP)
N.C
PI
PI
PI PI
PI
ISOLATION FLANGE,
GASKET KIT, AND
REDUCER
PI PI
BYPASS LINE
TO 1ST FLOOR WET PIPE
SPRINKLER SYSTEM
VS VS
V S
VS
WF
TO SECOND FLOOR WET PIPE
SPRINKLER SYSTEM
V S
VS2 x DIA 5 x DIA.
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ghg\D o cum ents\M y R evit\80720_FP_gh g.rvt
5/28/2020 8:25: 14 AM
FIRE PROTECTION, LEGEND,
ABBREVIATIONS, AND PIPING
SCHEMATIC
FP001
LFO
NRS
NRS
GENERAL NOTES
A. THE DESIGN AND INSTALLATION OF THE FIRE
PROTECTION SYSTEM SHALL BE IN STRICT
ACCORDANCE WITH UFC 4-021-01 (CHANGE 1
JANUARY 2010); ECB, 2018-17 (25 OCT 2018); UFC
3-600-01 (CHANGE 3, 10 MAY 2019); NFPA 13, 2019
EDITION; NFPA 20, 2019 EDITION; NFPA 70, 2017
EDITION; NFPA 72, 2019 EDITION; NFPA 90A, 2018
EDITION; ADOPTED STATE AND LOCAL CODES,
AND THE CONTRACT DOCUMENTS.
B. HISTORIC HYDRANT FLOW TEST CONDUCTED
11/27/2018 INDICATED A WATER SUPPLY WITH A
STATIC PRESSURE OF 49 PSI AND RESIDUAL
PRESSURE OF 44 PSI FLOWING 754 GPM.
CONTRACTOR SHALL PERFORM THEIR OWN
HYDRANT FLOW TEST ON WHICH THE HYDRAULIC
CALCULATIONS ARE BASED.
C. PROVIDE AUTOMATIC WET PIPE SPRINKLER
SYSTEM IN ACCORDANCE WITH UFC 3-600-01
REQUIREMENTS WITH DESIGN DENSITY AND
DESIGN AREA FOR THE HAZARD CLASSIFICATION
LISTED IN THE FIRE PROTECTION DESIGN
SCHEDULE.
D. ALL SYSTEM COMPONENTS SHALL BE U.L. LISTED
OR F.M. APPROVED.
E. THE INSPECTOR'S TEST VALVES SHALL BE
LOCATED NO MORE THAN 7 FEET AFF.
F. ALL HANGERS SHALL BE PROVIDED AND
INSTALLED IN ACCORDANCE WITH NFPA 13.
G. ALL VALVES (DRAINS, INSPECTOR'S TEST,
CONTROL) SHALL BE IDENTIFIED BY SIGNAGE AS
REQUIRED BY NFPA 13.
H. BRANCH LINES SHALL BE ARRANGED FOR
FLUSHING. READILY REMOVABLE FITTINGS SHALL
BE PROVIDED AT THE END OF ALL CROSS MAINS.
I. ALL SPRINKLERS SHALL BE INSTALLED IN THE
CENTER OF THE CEILING TILES +/- 6 INCHES.
J. ALL DRAINS AND TEST CONNECTIONS SHALL
DISCHARGE TO THE EXTERIOR OF THE BUILDING
ONTO CONCRETE SPLASH BLOCK OR PAVEMENT.
K. ALL CONTROL VALVES SHALL BE SUPERVISED BY
THE FIRE ALARM SYSTEM.
L. PROVIDE AUTOMATIC FIRE ALARM/MASS
NOTIFICATION SYSTEM WITH VISUAL/AUDIO
NOTIFICATION APPLIANCES IN ACCORDANCE WITH
UFC 3-600-01, UFC 4-021-01, ECB 2018-17, AND
NFPA 72 REQUIREMENTS.
M. SPEAKERS AND VISUAL NOTIFICATION SHALL BE
PROVIDED THROUGHOUT THE BUILDING FOR
VOICE INTELLIGIBILITY AND OCCUPANT
NOTIFICATION. EXTERIOR SPEAKER SHALL BE
PROVIDED IN PUBLIC AREAS AND ANY AREAS
COMMONLY USED BY OCCUPANTS.
N. VISUAL NOTIFICATION SHALL BE PROVIDED IN ALL
EMPLOYEE WORK, COMMON, AND PUBLIC AREAS.
O. MANUAL PULL STATIONS SHALL BE PROVIDED AT
THE BUILDING EXITS, EXITS ADJOINING ASSEMBLY
OCCUPANCIES, AND BOILER ROOM EXITS AND
SHALL BE EASILY ACCESSIBLE, UNOBSTRUCTED,
AND VISIBLE.
P. DUCT SMOKE DETECTORS SHALL BE PROVIDED IN
ALL HVAC MAIN SUPPLY DUCTS WHERE REQUIRED
BY NFPA 90A, IN RETURN DUCTS WHEN SYSTEMS
ARE GREATER THAN 15,000 CFM, AND SHALL HAVE
AUXILIARY CONTACTS TO PROVIDE CONTROL,
INTERLOCK, AND SHUTDOWN FUNCTIONS OF THE
HVAC SYSTEMS. DETECTORS SHALL BE POWERED
BY THE FIRE ALARM/MASS NOTIFICATION
CONTROL PANEL.
Q. ALL FIRE ALARM CIRCUITS SHALL BE INSTALLED IN
CONDUIT AND SHALL BE SECURELY FASTENED TO
THE STRUCTURE.
R. INSTALL SURGE PROTECTION DEVICES
EVERYWHERE FIRE ALARM WIRING ENTERS AND
EXITS THE BUILDING.
S. PROVIDE SMOKE DETECTION AT EACH POWER
EXTENDER PANEL.
T. PROVIDE SPRINKLERS BELOW ALL
OBSTRUCTIONS TO DISCHARGE, INCLUDING,
PLATFORMS, DOORS, AND DUCTS, PER NFPA 13.
U. PROVIDE AUTOMATIC AIR VENTS AT HIGH POINTS
OF PIPING TO VENT MINIMUM 98% OF THE
SYSTEM'S VOLUMETRIC CAPACITY. SLOPE PIPING
TO RISER, DRAIN TRAPPED PIPING
V. PROVIDE DRAIN VALVES FOR TRAPPED
SPRINKLER PIPING IN SPRINKLER PIPING.
DISCHARGE TO BUILDING EXTERIOR AT 18" ABOVE
GRADE ONTO CONCRETE SPLASH BLOCK.
W. COORDINATE SPEAKER LOCATIONS WITH LOC'S IN
ORDER TO PREVENT FEEDBACK.
SCALE NTS
FIRE ALARM MOUNTING HEIGHT DETAIL2SCALE NTS
FIRE PROTECTION PIPING SCHEMATIC1
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 Fa
SEAL
035238
ENG INEER
F
F F
F
F
F F
F
F
S
S S
S
S
P
LOC
C C
C
C
C
C
C
C
S C
C
S
S
FACU
P
ET
ET
ET
ET
ET
ET
FAA
C
C
ET
F
112 111
120119118
104105
AA
B B
C C
D D
E E
F F
FP401
PLATFORM TO MEZZ. PROVIDE
SPRINKLERS BELOW.
UP TO 2ND FLOOR.
REFER TO SHEET
FP102.
75cd
75cd
15cd
15cd
75cd
15cd
75cd
30cd
75cd
110cd
110cd
15cd
15cd
110cd
30cd
30cd
75cd
LOCATE LOC AWAY FROM
SPEAKER TO MINIMIZE
FEEDBACK
FROM SPRINKLER RISER.
REFER TO SHEET FP401
30cd
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ctj\D oc um ents\M y R evit\80720_FP_C Jo nesN
955U .rvt
3/10/2021 10:35 :28 AM
GROUND FLOOR FIRE
PROTECTION PLAN
FP101
LFO
NRS
NRS
SCALE 1/8" = 1'-0"
GROUND FLOOR FIRE PROTECTION PLAN1
FIRE PROTECITON DESIGN SCHEDULE - GROUND FLOOR
NUMBER NAME HAZARD NOTES
101 FIRE OH
102 COMM OH 1, 2, 3
103 CORRIDOR LH
104 ELEC OH 2, 3
105 TOILET LH
106 JOINT INSPECTION OH
107 FLEET STOR OH
108 CORRIDOR LH
109 STAIRS LH
111 CARGO OH
112 RAMP OH
113 PALLET BUILD-UP OH
114 LAV TRUCK OH
115 CIRCULATION OH
116 PPE TRAINING BAG OH
117 FLEET OFFICE LH
118 COFFEE LH
119 JAN OH
120 ELEV ELEVATOR
121 LOCKERS OH
122 BAGGAGE / PALLET OH
123 FLEET WORK OH
124 MEN LH
125 WOMEN LH
126 BAGGAGE SCAN OH
127 BAGGAGE CHECK-IN OH
128 PASSENGER HOLDING LH
129 PASSENGER HOLDING STERILE LH
130 BAGGAGE SCAN OH
131 CORRIDOR LH
NOTES:
1. PROVIDE CONCEALED SIDEWALL SPRINKLERS. DO NOT ROUTE
PIPING INTO THIS ROOM.
2. DO NOT RUN PIPING ABOVE ELECTRICAL EQUIPMENT.
3. ONLY PIPING SERVING THIS ROOM SHALL ENTER THIS ROOM.
0 4' 8' 16'
1/8" = 1'-0"
N
L
1 ADDENDUM #1 3/3/2021
SEAL
050568
ENGINEE
R
P
S
S C
S C
C
C
CC
C C
CC
C
C
C
S C
S C
C
C
C
P 135º°
203204
212 213
OPEN
TO
BELOW
A
B B
C C
D D
E
E
F F
ROOF
BELOW
PROVIDE SPRINKLERS
BELOW PLATFORM
PROVIDE DRY SIDEWALL SPRINKLERS
FOR OUTSIDE STAIR CANOPY
L 15cd
30cd
15cd
15cd
30cd30cd
15cd
15cd
15cd
15cd
30cd
30cd
15cd 15cd
UP FROM 1ST FLOOR. REFER TO
SHEET FP101. PROVIDE SPRINKLER
FLOOR CONTROL VALVE
ASSEMBLY
AHU-01
SUPPLY
MAU-01
SUPPLY
NEAR SPRINKLERS AT TOP
OF ELEV. HOISTWAY
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ghg\D o cum ents\M y R evit\80720_FP_gh g.rvt
5/28/2020 8:25: 20 AM
SECOND FLOOR FIRE
PROTECTION PLAN
FP102
LFO
NRS
NRS
SCALE 1/8" = 1'-0"
SECOND FLOOR FIRE PROTECTION PLAN1
FIRE PROTECITON DESIGN SCHEDULE - SECOND FLOOR
NUMBER NAME HAZARD NOTES
201 STAIRS LH 2
202 CORR LH
203 TOILET LH
204 TOILET LH
205 CORRIDOR LH
206 ATOC LH
207 DCC LH
208 ADMIN LH
209 IDO LH
210 SIPR LH
211 CORR LH
212 LOAD PLANNING LH
213 COFFEE / BREAKRM LH
214 TO LIBRARY / HOTEL / QC LH
215 CONF LH
216 CORR LH
217 CORR LH
218 SUPERVISOR / MANAGER LH
219 ELEV ELEVATOR 1
220 ADMIN LH
221 MECH. OH
NOTES:
1. ELEVATOR EQUIPMENT ROOM IS AT TOP OF SHAFT. PROVIDE
AN ORDINARY OR INTERMEDIATE TEMPERATURE RATED
SPRINKLER WITH A GUARD AT THE TOP OF THE SHAFT,
CONTROL VALVE WITH TAMPER SWITCH, SMOKE AND HEAT
DETECTOR AND ELEVATOR SHUNT STRIP PER NFPA 13 AND
NFPA 72.
2. PROVIDE SPRINKLER AT TOP OF STAIR.
0 4' 8' 16'
1/8" = 1'-0"
N
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 Fa
SEAL
FA
P
X
FAPX
F
S
P
B B
C C
FP401
FP401
FIRE PUMP CONTROLLER
JOCKEY PUMP CONTROLLER
MONACO CONTROL PANEL
DOUBLE DETECTOR CHECK
BFP W/TAMPER SWITCH
6" DI POLY WRAPPED FP SUPPLY
PIPE. REFER TO SHEET C110 FOR
CONT.
OS&Y VALVE
W/TAMPER SWITCH
ELECTRIC VERTICAL IN-LINE
FIRE PUMP ON 6" CONCRETE
HOUSEKEEPING PAD
CHECK VALVE
OS&Y VALVE
W/TAMPER SWITCH
RISER CHECK VALVE
MAIN DRAIN
FDC CHECK VALVE
TO WP-1
SPRINKLERS
JOCKEY PUMP ON 6" CONCRETE
HOUSEKEEPING PAD
SPLASH BLOCK
(1) 2-1/2" PUMP AND
BFP TEST HEADER
CONN.
BUTTERFLY VALVE
W/TAMPER SWITCH
(NORMALLY CLOSED)
OS&Y VALVE
W/TAMPER SWITCH
FIRE
WATERFLOW
HORN/STROBE
W/SIGNAGE110cd
FDC
BC
TO SPRINKLER RISER
JOCKEY PUMP ON 6" CONCRETE
HOUSEKEEPING PAD
OS&Y VALVE
W/TAMPER SWITCH
OS&Y VALVE
W/TAMPER SWITCH
DOUBLE DETECTOR
CHECK BFP W/TAMPER
SWITCH
FLOW METER
OS&Y VALVE
W/TAMPER SWITCHVG
ELECTRIC VERTICAL IN-LINE
FIRE PUMP ON 6" CONCRETE
HOUSEKEEPING PAD 6" DI POLY WRAPPED FP SUPPLY
PIPE. REFER TO SHEET C110 FOR
CONT.
TO BFP TEST HEADER
MAIN DRAIN FROM
SPRINKLER RISER
MAIN DRAIN
SPLASH BLOCK
CHECK VALVE
FIRE
BYPASS LINE
5 x DIA. 2 x DIA.
FROM FIRE PUMP
OS&Y VALVE W/TAMPER
SWITCH
RISER CHECK VALVE
MAIN DRAIN
FROM FDC
NAC EXTENDER
PANEL
TO WP-1 SPRINLKERS
FA/MNS SPEAKER
WATERFLOW SWITCH
FIRE
PROVIDE GROOVED
TEE FOR FUTURE
EXPANSION
B B
C C
AIM
AIM
BFP
AIM
AIM
AIM
AIM
BYPASS
FIRE
PUMP
AIM
AIM
FLOW
METER AIM
BFP TEST
HEADERVS
VS
VS
VS
VS
VS
VS
VS
VS
AIM
AIM
SPRINKLER
RISER
VS
WF
AIM FIRE PUMP
RUNNING
AIM
FIRE PUMP
CONTROLLER
MAIN SWITCH
NOT IN AUTO
AIM
FIRE PUMP
ALTERNATE
POWER
SOURCE
AIM
FIRE PUMP
AC POWER
LOSS
AIM FIRE PUMP
PHASE
REVERSAL
FIRE
AIM
AIM
JOCKEY
PUMP
VS
VS
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ghg\D o cum ents\M y R evit\80720_FP_gh g.rvt
5/28/2020 8:25: 23 AM
FIRE PROTECTION ENLARGED
PLANS AND SECTIONS
FP401
LFO
NRS
NRS
SCALE 1/2" = 1'-0"
FIRE ROOM 101 ENLARGED PLAN1
SCALE 1/2" = 1'-0"
FIRE PUMP SECTION4
SCALE 1/2" = 1'-0"
SPRINKLER RISER SECTION3
0 1' 2' 4'
1/2" = 1'-0"
N
SCALE NTS
FIRE ROOM 101 DEVICE PLAN2
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 Fa
SEAL
101 102
FIRE ALARM
CONTROL UNIT
RM 127
LOC
120V
(2) TELEPHONE LINE
A118
30cd
ROOM
CANDELA RATING
DEVICE LEGEND
WATERFLOW
HORN/STROBE.
W/"WATERFLOW"
SIGNAGE
110cd
SPD
DACT
15cd
C c c c
S c c c c
15cd 15cd c c
205 204
15cd 15cd c c
203 202
75cd 110cd c c
130 129 c c cccc c
S c ccc S c
S c
S c ccc
EXTERIOR
S c
EXTERIOR
EOL
F
15cd
15cd
75cd
15cd
75cd
75cd
75cd
75cd
15cd
116 117
75cd
15cd
110cd
30cd
30cd
15cd
15cd
15cd
30cd30cd15cd
30cd15cd 30cd 30cd 15cd 15cd
211 212 213 214 215 216 220 c
WP
SPD
VS
AIM
VS
AIM
FIRE
PUMP
VS
AIM
VS
AIM
JOCKEY
PUMP
VS
AIM
FIRE PUMP
TEST HEADER
(N.C.)
AIM
FIRE PUMP
CONTROLLER
MAIN SWITCH
NOT IN AUTO
AIM
FIRE PUMP
RUNNING
AIM
FIRE PUMP
AC POWER
LOSS
AIM
FIRE PUMP
PHASE
REVERSAL
AIM
FIRE PUMP
ALTERNATE
POWER
SOURCE
S S
SSSS
S
WP WP WP WP
WP
F
101101101101101101101101101101
F
F
F
F
F
114 122 P
ELEVATOR
F
F
127 127 P
FACU
F
F
VS
WF
BFP
AIMAIM
VS
AIM
WP-1
c
TRANSCEIVER
ANTENNA
F
F
216217 P
ELEVATOR
AIM
AHU-01
SUPPLY
F c
30cd
ET EOL
x 7
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ctj\D oc um ents\M y R evit\80720_FP_C Jo nesN
955U .rvt
3/10/2021 10:35 :29 AM
FIRE ALARM & MASS
NOTIFICATION RISER DIAGRAM
FP501
LFO
NRS
NRS
SCALE NTS
FIRE ALARM RISER DIAGRAM1
1 ADDENDUM #1 3/3/2021
SEAL
050568
SYSTEM INPUTS
MANUAL FIRE ALARM PULL STATIONS1
AC
TU
AT
E
CO
M
M
ON
A
LA
RM
S
IG
NA
L
IN
DI
CA
TO
R
A
AC
TU
AT
E
AU
DI
BL
E
AL
AR
M S
IG
NA
L
B
AC
TU
AT
E
CO
M
M
ON
S
UP
ER
VI
SO
RY
S
IG
NA
L
IN
DI
CA
TO
R
C
AC
TU
AT
E
AU
DI
BL
E
SU
PE
RV
IS
OR
Y
SI
GN
AL
D
AC
TU
AT
E
CO
M
M
ON
T
RO
UB
LE
S
IG
NA
L
IN
DI
CA
TO
R
E
AC
TU
AT
E
AU
DI
BL
E
TR
OU
BL
E
SI
GN
AL
F
AC
TU
AT
E
AU
DI
BL
E
NO
TI
FI
CA
TI
ON
A
PP
LI
AN
CE
S
G
AC
TU
AT
E
VI
SI
BL
E
NO
TI
FI
CA
TI
ON
A
PP
LI
AN
CE
S
H
DI
SP
LA
Y/
PR
IN
T
CH
AN
GE
O F
ST
AT
US
I
TR
AN
SM
IT
F
IR
E
AL
AR
M
S
IG
NA
L
TO
S
UP
ER
VI
SI
NG
S
TA
TI
ON
J
TR
AN
SM
IT
F
IR
E
SU
PE
RV
IS
OR
Y
SI
G
NA
L
TO
S
UP
ER
VI
SI
NG
S
TA
TI
ON
K
TR
AN
SM
IT
F
IR
E
TR
O
UB
LE
S
IG
NA
L
TO
S
UP
ER
VI
SI
NG
S
TA
TI
O
N
L M N O P Q
SH
UT
DO
W
N
AS
SO
CI
AT
ED
A
IR
H
AN
DL
IN
G
UN
IT
R
AC
TU
AT
E
PR
IM
AR
Y
FL
OO
R
EL
EV
AT
OR
R
EC
AL
L
U
AC
TU
AT
E
AL
TE
RN
AT
E
FL
OO
R
EL
EV
AT
OR
R
EC
AL
L
V
AC
TU
AT
E
EL
EV
AT
O
R
SH
UN
T
TR
IP
C
IR
CU
IT
B
RE
AK
ER
W X Y Z
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AA BB CC
DE
-A
CT
IV
AT
E
FI
RE
A
LA
RM
N
OT
IF
IC
AT
IO
N
AP
PL
IA
NC
ES
IF
A
CT
IV
E(
VI
SU
AL
AC
TI
VA
TE
M
AS
S
NO
TI
FI
CA
TI
ON
S
TR
O
BE
S
TR
AN
SM
IT
M
AS
S
NO
TI
FI
CA
TI
O N
SI
GN
AL
T
O
SU
PE
RV
IS
IN
G
ST
AT
IO
N
DE
-A
CT
IV
AT
E
M
AS
S
NO
TI
FI
CA
TI
O N
SI
GN
AL
A
FT
ER
M
IN
UT
ES
SMOKE DETECTOR - PANEL
HEAT DETECTOR
WATERFLOW SWITCH
DUCT SMOKE DETECTOR
SMOKE DETECTOR - 1ST FLOOR ELEVATOR LOBBY
SMOKE DETECTOR - ALL OTHER ELEVATOR LOBBIES
SMOKE DETECTOR - ELEVATOR EQUIPMENT ROOM
HEAT DETECTOR - ELEVATOR EQUIPMENT ROOM
SHUNT TRIP BREAKER - CONTROL POWER SUPERVISION
VALVE TAMPER SWITCH
FIRE ALARM CONTROL PANEL AC POWER FAILURE
FIRE ALARM CONTROL PANEL LOW BATTERY
OPEN CIRCUIT
GROUND FAULT
NOTIFICATION APPLIANCE CIRCUIT SHORTED
ALL OTHER TROUBLES
ACU MICROPHONE KEYED-ALL CALL
LOC MICROPHONE KEYED-ALL CALL
MASS NOTIFICATION SYSTEM SWITCH INPUT 1
MASS NOTIFICATION SYSTEM SWITCH INPUT 2
MASS NOTIFICATION SYSTEM SWITCH INPUT 3
MASS NOTIFICATION SYSTEM SWITCH INPUT 4
MASS NOTIFICATION SYSTEM SWITCH INPUT 5
MASS NOTIFICATION SYSTEM SWITCH INPUT 6
MASS NOTIFICATION SYSTEM SWITCH INPUT 7
MASS NOTIFICATION SYSTEM SWITCH INPUT 8
MASS NOTIFICATION SYSTEM ACTIVATED DURING FIRE EVENT
TS
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
ON
M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
AC
TU
AT
E
AS
SO
CI
AT
ED
M
AS
S
NO
TI
FI
CA
TI
O
N M
ES
SA
GE
ALARM CONDITIONS
SUPERVISORY CONDITIONS
TROUBLE CONDITIONS
MASS NOTIFICATION CONDITIONS
A B C D E F G H I J K L M N O P Q R U V W X Y Z AA BB CCTS
AC
TU
AT
E
W
AT
ER
FL
O W
H
OR
N/
ST
RO
BE
SYSTEM OUTPUTS
CONTROL UNIT
ANNUNCIATION NOTIFICATION AUXILIARY FUNCTIONS MASS NOTIFICATION SYSTEM
DD
DD
EE
EE FF GG HH II JJ KK LL MM
FF GG HH II JJ KK LL MM NN
NN
FIRE PUMP RUNNING
FIRE PUMP CONTROLLER MAIN SWITCH NOT IN AUTO
FIRE PUMP ALTERNATE POWER SOURCE
FIRE PUMP ROOM LOW TEMPERATURE
FIRE PUMP REVERSAL
HVAC EMERGENCY SHUT DOWN SWITCH
SH
UT
DO
W
N
AL
L
HE
AT
IN
G, V
EN
TI
LA
TI
NG
, A
ND
A
IR
C
ON
DI
TI
ON
IN
G
PE
R
UF
C
4-
1-
S
EC
TI
ON
-4
.2
EMERGENCY SHOWER/EYEWASH STATION
PP QQ RR SS TT UU VV
PP QQ RR SS TT UU VV
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
C :\U sers\ghg\D o cum ents\M y R evit\80720_FP_gh g.rvt
5/28/2020 8:25: 18 AM
FIRE ALARM & MASS
NOTIFICATION INPUT/OUTPUT
MATRIX
FP601
LFO
NRS
NRS
SCALE NTS
FIRE ALARM & EMERGENCY COMMUNICATIONS INPUT/OUTPUT MATRIX1
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 Fa
SEAL
CO
HB
C
CO
Ø.................................ROUND
ϕ..................................PHASE
Ø............................DIAMETER
°...............................DEGREE
∠..................................ANGLE
%.............................PERCENT
TEXT SYMBOLS
CHECK VALVE (SWING GATE)
(GPM)
WH
A
ABBREVIATIONSDESCRIPTIONSYMBOL
NPW NON-POTABLE WATER (MAKE-UP)
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
SOIL OR WASTE VENTV
SOIL OR WASTE - ABOVE FLOORSS
COMPRESSED AIR - ABOVE FLOORA
SOIL OR WASTE - BELOW FLOOR
OR GRADESS
COMPRESSED AIR - BELOW FLOOR
OR GRADEA
DRAIND
NATURAL GAS, LOW
PRESSURE (0.5 PSI)G
NATURAL GAS, MEDIUM
PRESSURE (50 PSIG)MG
FIRE PROTECTION MAINFP
CONDENSATE DRAINCD
RISER DOWN (ELBOW)
RISER UP (ELBOW)
RISE OR DROP
TEE DOWN
TEE UP
TOP CONNECTION
BOTTOM CONNECTION
SIDE CONNECTION
BALL VALVE
GATE VALVE OR ISOLATION VALVE
CIRCUIT BALANCING VALVE -
SET FOR GPM SHOWN IN ().
ANGLE VALVE
CHECK VALVE (STRAIGHT)
GLOBE VALVE
PRESSURE REDUCING VALVE
ASME RELIEF VALVE
PRESSURE AND
TEMPERATURE RELIEF
REDUCER, ECCENTRIC
REDUCER, CONCENTRIC
CLEANOUT, FLOOR
CLEANOUT, WALL
WATER HAMMER ARRESTOR
STRAINER, "Y" TYPE
DOUBLE CHECK VALVE BACKFLOW
PREVENTION DEVICE
REDUCED PRESSURE BACKFLOW
PREVENTER W/STRAINER
HOSE BIBB
WALL HYDRANT
PIPE ANCHOR
PIPE SLEEVE THRU
WALL, FOOTING ETC
FLOW IN DIRECTION OF ARROW
PIPE SLOPE IN
DIRECTION OF ARROW
T1
THERMOMETER
THERMOMETER WELL
TW
PI
PRESSURE GAUGE WITH GAUGE
COCK (C=COMPOUND GAUGE)
LUBRICATED PLUG VALVE
UNION
BLIND FLANGE
CAP
COMPRESSED AIR RELIEF VALVE
RELIEF VALVE
PIPE ROUTED TO FLOOR DRAIN
LAVATORY
WATER CLOSET
URINAL
SERVICE SINK/BASIN
SINK
SHOWER HEAD
DRINKING FOUNTAIN
FLOOR DRAIN
COMPRESSED AIR OUTLET STATION
ABV* ABOVE
AFF ABOVE FINISHED FLOOR
AGA AMERICAN GAS ASSOCIATION
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECT,ARCHITECTURAL
AUTO AUTOMATIC
AUX AUXILIARY
AVG AVERAGE
B/B BACK TO BACK
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BLDG BUILDING
BTU BRITISH THERMAL UNIT
BTUH BTU/HOUR
CA* COMPRESSED AIR
CAP CAPACITY
CBV* CIRCUIT BALANCING VALVE
CFH* CUBIC FEET PER HOUR
CI CAST IRON
CL CENTER LINE
CLG CEILING
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECT
CONT CONTINUE, CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CP* CHROME PLATED
CTR CENTER
CW COLD WATER
D DRAIN
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGRAM, DIAGRAMMATIC
DN DOWN
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWV DRAIN, WASTE, VENT
E EAST
EA EACH
EL ELEVATION
ELEC ELECTRIC
ELL* ELBOW
EMER EMERGENCY
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EST ESTIMATE
ETC ET CETERA (AND SO FORTH)
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXT EXTERIOR
F FAHRENHEIT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FF* FINISHED FLOOR
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
FH FIRE HYDRANT
FLA FULL LOAD AMPS
FLEX FLEXIBLE
FLR FLOOR
FM FACTORY MUTUAL
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FOOT, FEET
FTG FOOTING
FURN FURNISHED
FV FLUSH VALVE
FIG FIGURE
FIXT FIXTURE
G NATURAL GAS
GA GAGE, GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GPH GALLON PER HOUR
GPM GALLON PER MINUTE
HB HOSE BIBB
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HORSEPOWER
HR* HOUR
HSKPG HOUSEKEEPING
HT HEIGHT
HW HOT WATER
HWR HOT WATER RETURN
HYD HYDRAULIC
HYD HYDRANT
Hz HERTZ
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN WC INCHES WATER COLUMN
IN* INCHES
INFO INFORMATION
INSUL INSULATION
INV EL INVERT ELEVATION
IPC* INTERNATIONAL PLUMBING CODE
IPS IRON PIPE SIZE
ISO ISOMETRIC
JAN CLO JANITOR'S CLOSET
K THOUSAND
KW KILOWATT
KWH KILOWATT HOUR
L LITER
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET (FOOT)
LKR LOCKER
MA* MEDICAL AIR
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MED MEDIUM
MEZZ MEZZANINE
MFG MANUFACTURING
MFR MANUFACTURER
MG* MEDIUM PRESSURE NATURAL GAS
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODIFY
MTD MOUNTED
MULT MULTIPLE
N NORTH
NA NOT APPLICABLE
NCS* NATIONAL CAD STANDARDS
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPW NONPOTABLE WATER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPT OPTIONAL
DESCRIPTIONSYMBOL
OPP OPPOSITE
ORIG ORIGINAL
OUT OUTLET
OZ OUNCE
PCT PERCENT
PH PHASE
PKG PACKAGE
PLBG PLUMBING
PPM PARTS PER MILLION
PRELIM PRELIMINARY
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQ. IN. ABSOLUTE
PSIG POUNDS PER SQ. IN. GAGE
PVC POLYVINYL CHLORIDE
PWR POWER
QA QUALITY ASSURANCE
QTY QUANTITY
RD ROOF DRAIN
REF REFERENCE
REQD REQUIRED
REV REVISE, REVISION
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RM ROOM
RPBP* REDUCED PRESSURE
BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
RPS REVOLUTIONS PER SECOND
S SOUTH
s* SECOND
SCHED SCHEDULE
SCHEM SCHEMATIC
SECT SECTION
SF SQUARE FEET (FOOT)
SPEC SPECIFICATION
SQ SQUARE
STOR STORAGE
STRUCT STRUCTURAL
SYS SYSTEM
T&P TEMPERATURE AND PRESSURE
TECH TECHNICAL
TEMP TEMPERATURE
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
THRU THROUGH
TSTAT THERMOSTAT
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
V* VOLT
VOL VOLUME
VTR VENT THRU ROOF
W WATT
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSE
WC WATER COLUMN
WG WATER GAGE
WH WATER HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTOR
WT WEIGHT
XFMR TRANSFORMER
YH YARD HYDRANT
YR YEAR
NOTES:
1. NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED ON THIS PROJECT.
2. ABBREVIATIONS WITH * PREFIX ARE NOT INCLUDED IN THE CURRENT NATIONAL CAD STANDARDS.
STORM DRAINSD
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec tN o.
:F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
,N C
N or th C ar ol in a
A ir
N at io na lG ua rd C
-1
C on ve rs io n:
A dd
/A lte rS m al lT er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
5/27/2020 8:59: 52
AM
LEGEND & ABBREVIATIONS
P-001
LLP
WBB
WBB
GENERAL NOTES
(APPLIES TO ALL SHEETS)
A. SLOPE SOIL AND WASTE PIPE 4" AND LARGER
AT 1/8" PER FT. MINIMUM, SIZE LESS THAN 4"
SLOPE 1/4" PER FT. MINIMUM, UNLESS NOTED
OTHERWISE.
B. ALL PIPING SHALL BE COORDINATED WITH
CIVIL UTILITY PIPING, FIRE PROTECTION,
DUCTWORK, MECHANICAL PIPING, LIGHTING,
STRUCTURAL AND ARCHITECTURAL SYSTEMS.
C. PIPE CLEANOUTS SHALL BE LINE SIZE (6"
MAX.). LOCATE 100' APART MAXIMUM FOR
SIZES UP THROUGH 6".
D. PLUMBING VENTS THROUGH ROOF (VTR)
SHALL BE 3" MINIMUM. SMALLER VTR'S
INDICATED SHALL INCREASE TO 3" PIPE, 12"
BELOW ROOF. INSTALL VENT THRU ROOF (VTR)
PENETRATIONS PER ROOFING
MANUFACTURER'S RECOMMENDATIONS.
E. ACCESS PANELS SHALL BE PROVIDED FOR ALL
WATER HAMMER ARRESTORS LOCATED IN
WALLS TO ACCESS EQUIPMENT. PANEL SHALL
BE AS LARGE AS PRACTICAL FOR THE
FUNCTION THEY ARE INTENDED.
F. ALL FLOOR DRAINS AND FLOOR SINKS SHALL
HAVE TRAP PRIMERS.
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 F
SEAL
ALL BELOW-GRADE
PLUMBING PIPING TO BE
CAPPED & ABANDONED
EXCEPT FOR STORM DRAIN
PIPING & UNLESS
OTHERWISE NOTED
8 8
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
EXISTING 8" SD
TO REMAIN
DEMO EXISTING 4"
SD TO THIS POINT
DEMO EXISTING 4" SD
TO ABOVE FLOOR
DEMO EXISTING
DOMESTIC WATER
ENTRANCE TO
BELOW FLOOR
AND CAP
ABANDON EXISTING
WATER LINE
ALL PLUMBING EQUIPMENT,
PIPING, & ACCESSORIES TO
BE DEMOLISHED UNLESS
NOTED OTHERWISE.
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
9 10 9 9
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec tN o.
:F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
,N C
N or th C ar ol in a
A ir
N at io na lG ua rd C
-1
C on ve rs io n:
A dd
/A lte rS m al lT er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
5/27/2020 8:59: 36
AM
PLUMBING DEMOLITION -
UNDERFLOOR & FIRST FLOOR
PD101
LLP
WBB
WBB
SCALE 1/8" = 1'-0"
UNDERFLOOR PLUMBING - DEMOLITION1
SCALE 1/8" = 1'-0"
GROUND FLOOR PLUMBING - DEMOLITION2
SHEET KEYNOTES
GENERAL NOTES
N
0 4' 8' 16'
1/8" = 1'-0"
1. EXISTING FIXTURE TO BE DEMOLISHED.
SANITARY SEWER, VENT, & DOMESTIC WATER
PIPING TO BE CAPPED BELOW FLOOR OR
REMOVED AS REQUIRED FOR NEW WORK.
2. APPROXIMATE LOCATION OF EXISTING
DOMESTIC WATER ENTRANCE, PIPING TO BE
DEMOLISHED TO BELOW FLOOR AND CAPPED.
3. DEMO FITTINGS AND CAP LATERALS.
4. DEMO TO ABOVE FINISHED FLOOR.
5. EXISTING SANITARY SEWER PIPING BELOW
FLOOR TO BE DEMOLISHED OR ABANDONED AS
REQUIRED FOR NEW WORK (NOT ALL EXISTING
PIPING IS SHOWN).
6. NOT USED
7. NOT USED
8. APPROXIMATE EXTENTS (SHOWN CROSS-
HATCHED) OF FLOOR SLAB DEMOLITION
REQUIRED FOR NEW WORK. CONTRACTOR TO
SUBMIT FULL SHOP DRAWINGS FOR APPROVAL
FROM ENGINEER PRIOR TO COMMENCEMENT
OF FLOOR DEMOLITION.
9. DEMO EXISTING 4" VERTICAL SD TO 6" ABOVE
FLOOR AND CAP.
10. DEMO EXISTING 4" VERTICAL SD TO BELOW
FLOOR AND CAP.
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
B. EXISTING SANITARY SEWER PIPING BELOW
GRADE TO BE ABANDONED UNLESS NOTED
OTHERWISE.
C. EXISTING SANITARY & VENT PIPING ABOVE
GRADE TO BE DEMOLISHED.
D. EXISTING STORM DRAIN PIPING TO REMAIN
UNLESS NOTED OTHERWISE.
E. EXISTING DOMESTIC WATER PIPING TO BE
DEMOLISHED.
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 F
SEAL
LOW ROOF, RE: ROOF PLAN
OPEN TO BELOW
OPEN TO BELOW
ALL PLUMBING EQUIPMENT,
PIPING, & ACCESSORIES TO
BE DEMOLISHED.
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
4 4 4 4
1 1 1 1
FOR MECH. EQUIP., RE: MECH. PLANS
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec tN o.
:F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
,N C
N or th C ar ol in a
A ir
N at io na lG ua rd C
-1
C on ve rs io n:
A dd
/A lte rS m al lT er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
5/27/2020 8:59: 55
AM
PLUMBING DEMOLITION -
SECOND FLOOR & ROOF
PD102
LLP
WBB
WBB
SHEET KEYNOTES
GENERAL NOTES
1. DEMO EXISTING ROOF DRAIN INLETS TO ALLOW
NEW ROOF DRAINS (WITH DOME STRAINERS)
TO BE INSTALLED IN SAME LOCATION &
ATTACHED TO EXISTING PIPING BELOW DECK.
COORDINATE THIS DEMO & REPLACEMENT
WORK TO MINIMIZE RAIN WATER INTRUSION
INTO THE BUILDING BELOW OR PONDING ON
THE ROOF (IF DRAINS ARE BLOCKED DURING A
STORM).
2. EXISTING ROOF HATCH, TO BE RELOCATED, RE:
ARCH.
3. EXISTING ROOF HATCH ABOVE, TO BE
RELOCATED, RE: ARCH.
4. DEMO EXISTING 4" VERTICAL SD.
N
0 4' 8' 16'
1/8" = 1'-0"
SCALE 1/8" = 1'-0"
SECOND FLOOR PLUMBING - DEMOLITION1
SCALE 1/8" = 1'-0"
ROOF PLUMBING - DEMOLITION2
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
B. EXISTING SANITARY & VENT PIPING ABOVE
GRADE TO BE DEMOLISHED.
C. EXISTING STORM DRAIN PIPING TO REMAIN
UNLESS NOTED OTHERWISE.
D. EXISTING DOMESTIC WATER PIPING TO BE
DEMOLISHED.
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 F
SEAL
2 1/2"
4"
4"
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
FIRE
C O
M M
C O
R R
ID
O
R
ELEC
UNISEX
RAMP 111
CARGO
FLEET
STOR
JOINT
INSPECTION
LOCKERS
PPE
TRAINING
BAG
FLEET
OFFICE
COFFEE
JAN
ELEV
BAGGAGE
SCAN
CORRIDOR
FLEET
WORK
MEN
WOMEN
STAIR
#1
PALLET
BUILD-UP
LAV
TRUCK
CIRCULATION
BAGGAGE
CHECK-IN
PASSENGER
HOLDING
PASSENGER
HOLDING
STERILE
3 47
4 3
3"
11 5
3"
2"
4" 4"
2"
2"
2"
2"
2"
SS
SS
SS
SS
SS
SS
3" SS UP
15 158" SD
CONNECT TO
EXISTING 8" SD
UP
SD
6"
EXISTING 8" SD
TO REMAIN
16 16 16
17 ESP, REFER
TO 11/P-501
IE = 96'-11"
4" SS UP
SS
4"
IE = 96'-1"
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec tN o.
:F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
,N C
N or th C ar ol in a
A ir
N at io na lG ua rd C
-1
C on ve rs io n:
A dd
/A lte rS m al lT er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
5/27/2020 8:59: 47
AM
UNDERFLOOR PLUMBING
P-101
LLP
WBB
WBB
SHEET KEYNOTES
GENERAL NOTES
1. REFER TO CIVIL SHEET C110 FOR
CONTINUATION.
2. NEW 2 1/2" DOMESTIC WATER SERVICE FROM
BELOW.
3. 2" VENT UP.
4. 2" SS UP FROM 2" TRAP.
5. 3" SS UP FROM 3" TRAP.
6. APPROXIMATE LOCATION OF EXISTING WASTE
PIPING SYSTEM TO BE ABANDONED, SHOWN
THIS PLAN FOR REFERENCE ONLY.
7. 4" SS UP FROM 4" TRAP.
8. 6" SD UP.
9. 4" SS FROM FLOOR ABOVE.
10. 3" SS FROM FLOOR ABOVE.
11. 2" SS UP.
12. 6" SD @ 1/8" PER FOOT SLOPE MINIMUM.
13. 4" SS UP.
14. 2" SS DOWN, 2" VENT UP.
15. 1/2" TRAP PRIMER LINE UP.
16. EXISTING STORM DRAIN TO BE ABANDONED.
17. 2" FROM SUMP PUMP UP TO ABOVE FLOOR.
18. COORDINATE LOCATION OF SUMP PUMP WITH
REQUIREMENTS OF ELEVATOR SUPPLIER.
N
0 4' 8' 16'
1/8" = 1'-0"
SCALE 1/8" = 1'-0"
UNDERFLOOR PLUMBING PLAN1
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
B. EXISTING BUILDING SLAB TO REMAIN
UNDISTURBED EXCEPT FOR NEW WORK AREAS
& AS APPROVED OR REQUIRED BY ARCHITECT.
C. UPON COMPLETION OF PIPING BELOW GRADE
REPAIR CONCRETE FLOOR, WHERE SAW CUT,
TO MATCH EXSISTING.
D. ANY ABANDONED IN PLACE PIPING MAY BE CUT
OR REMOVED FOR INSTALLATION OF NEW
PIPING TO COMPLETE WORK.
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 F
SEAL
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
SD
6"
1/8" PER FOOT
SLOPE MIN
V
6" SD DN
SS
25 25
2" VENT UP
3/4"
V
2"
1 1/2" 1 1/2"
3/4"
HIGH AS
POSSIBLE1"
P-
P-
P-
P-
P-
P-
P-
P-7
P-6 P-9
2 1/2"
4" FS
2"
P-
P-4 P-8
1 1/2" 2 1/2"
P-1 P-2
P-5 P-5P-
P-10
FIRE
1"
4" FS
4" FS
3"
COMM
C O
R R
ID
O
R
ELEC
UNISEX
RAMP
CARGO
FLEET
STOR
JOINT
INSPECTION
LOCKERS
PPE
TRAINING
BAG
FLEET
OFFICE
COFFEE
JAN
ELEV
BAGGAGE
SCAN
CORRIDOR
FLEET
WORK
MEN
WOMEN
STAIR
#1
PALLET
BUILD-UP
LAV
TRUCK
CIRCULATION
BAGGAGE
CHECK-IN
PASSENGER
HOLDING
PASSENGER
HOLDING
STERILE
28 28
WATER
FILTERS
3/4" CW UP
8" SD FROM
ABOVE
EXISTING 4"
SD DOWN
P-
2"
4" FCO
FCO
DBP
FCO
2 1/2"
PUMP
ROOM
BFP2
356" SD FROM
ABOVE
6" SD
DOWN
3/4"
WH
WH
WH
3 WH
3 WH
3/4"
3/4" CW FROM
ABOVE THRU
BALL VALVE
3/4" CW FROM
ABOVE THRU
BALL VALVE
HB
2" SUMP PUMP LINE FROM
BELOW. DISCHARGE TO
MOP SINK AS SHOWN
THRU AIR GAP.
FCO WITH
DUCTILE
IRON TOP 4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
2/23/2021 12:44 :36 PM
GROUND FLOOR PLUMBING
P-102
LLP
WBB
WBB
SHEET KEYNOTES
GENERAL NOTES
1. 2 1/2" DOMESTIC WATER SERVICE UP FROM
BELOW GRADE. STAY BELOW FIRE
PROTECTION WALL PANELS.
2. 2" BACKFLOW PREVENTER. MOUNT BELOW FIRE
PROTECTION WALL PANELS.
3. HOSE BIBB OR WALL HYDRANT, 18" AFF OR ABV
FINISHED GRADE.
4. 2" FD.
5. LOCATION OF WATER HEATER INTAKE & FLUE
THRU-WALL TERMINAL, REFER TO MECH.
6. DOMESTIC WATER HEATER DWH, 199,000 BTU.
7. THERMOSTATIC MIXING VALVE (TMV) MOUNTED
ON WALL.
8. HOT WATER CIRCULATOR PUMP (CP1),
MOUNTED ON WALL.
9. EXPANSION TANK FOR DOMESTIC HOT WATER
SYSTEM, SUSPENDED UP HIGH.
10. 3/4" COLD WATER UP.
11. 3" VENT UP THRU ROOF.
12. 2" VENT UP TO FLOOR ABOVE.
13. 4" SS FROM FLOOR ABOVE.
14. 4" SS DOWN TO BELOW FLOOR.
15. 3" SS FROM MECH RM FLOOR DRAINS TO
BELOW FLOOR.
16. 3/4" HW AND 1/2" CW TO DISHWASHER.
17. OWNER FURNISHED ICE MAKER.
18. PROVIDE ACCESS AT BALL VALVE(S).
19. 6" SD FROM SRD ABOVE.
20. DOWNSPOUT NOZZLE, 18" ABV FINISHED
GRADE.
21. 2" VENT UP.
22. FLOOR CLEANOUT.
23. 2" SS DOWN TO FLOOR BELOW.
24. 3" FLOOR DRAIN.
25. 3" SS UP FROM 3" TRAP.
26. 2" VENT FROM BELOW.
27. 3/4" CW DOWN TO FILTERS.
28. EXISTING 4" SD TO REMAIN.
29. 4" SS FROM BELOW, 4" WCO ABOVE FLOOR,
THEN 2" VENT UP.
30. 3/4" TO P-11 MOUNTED ON WALL.
31. 3/4" TO ICE MAKER.
32. WCO ABOVE FLOOR, 4" SS DOWN, 1 1/2" VENT
UP, CONNECT TO 2" VENT, 2" VENT UP.
33. 1/2" CW DOWN THRU TRAP PRIMER VALVE,
ROUTE LINE TO DISCHARGE TO FLOOR
SINK/DRAIN THRU AIR GAP.
34. 2" SS UP FROM 2" TRAP AND 1/2" TRAP PRIMER
LINE UP, TYP OF 2 @ 2ND FLOOR RESTROOMS.
35. PROVIDE LAV DRAIN TRAP PRIMER.
36. 1/2" COMPRESSED AIR FROM ABOVE WITH DRIP
LEG.
37. NOT USED
38. POWDER COATED HOSE REEL WITH 1/4" ID, 40
FT, 300 PSI HOSE WITH 1/4" QUICK DISCONNECT.
39. ELECTRIC VENTLESS DOOR-STYLE
DISHWASHING MACHINE COMPLETE WITH THE
FOLLOWING OPTIONS, PRESSURE REGULATING
VALVE, WATER HAMMER ARRESTOR KIT,
SINGLE POINT ELECTRIC KIT (FIELD INSTALLED)
AND DRAIN WATER TEMPERING KIT.
40. WH ABOVE DOWNSPOUT NOZZLE (APPROX 2' 6"
AFF)
N
0 4' 8' 16'
1/8" = 1'-0"
SCALE 1/8" = 1'-0"
GROUND FLOOR PLUMBING PLAN1
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
1 ADDENDUM #1 03/03/2021
SEAL
050568
Tectonic Copyright 2007
LOW ROOF
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
SD
SD
3/4" CW UP
TO RH
3" FD
3" FD
PRDPRD
SRDSRD
2" F
D P-
P-
P-
P- 4P-6 2" F
D
3" VTR
MECH.
CORR
DCC
ADMIN
IDO
SIPR
ATOC
UNISEX
UNISEX
CONF
CORR
SUPERVISOR
MANAGER
CORR
TO
LIBRARY
HOTEL
/ QC
BREAKRM
LOAD
PLANNING
CORR
CORRIDOR
ADMIN
LAV
TRUCK
STAIR
#1
ELEV
SD
WH8" SLOPED @
1/4" PER FOOT
MINIMUM
8" SLOPED @
1/8" PER FOOT
MINIMUM
8" SLOPED @
1/8" PER FOOT
MINIMUM
6" SLOPED @
1/8" PER FOOT
MINIMUM
UB
12 3
SD
16 17 151515
SD SD
6" SD DOWN
A
A
1/2"
10' MIN BETWEEN
PLUMBING VENTS
AND AIR INTAKES
3/4" CW
DOWN
3/4" CW
DOWN
3/4" CW
FROM
BELOW
3/4" CW APPROX 22'
ABOVE FINISHED
FLOOR
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec t N o.
: F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
, N C
N or th C ar ol in a
A ir
N at io na l G ua rd C
-1
C on ve rs io n:
A dd
/A lte r S m al l T er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
2/23/2021 12:44 :39 PM
SECOND FLOOR PLUMBING
P-103
LLP
WBB
WBB
SHEET KEYNOTES
GENERAL NOTES
1. 1 1/2" COLD WATER FROM BELOW.
2. 3" VENT FROM BELOW, 3" VTR.
3. 3/4" COLD WATER FROM BELOW UP THRU BALL
VALVE WITH HB IN VERTICAL.
4. 3/4" CW FROM BELOW.
5. 3/4" BACKFLOW PREVENTER (BFP2).
6. 3/4" NPW FOR MAKEUP WATER CONNECTION
FOR HEATING WATER SYSTEM. REF MECH.
7. 2" VENT FROM BELOW, OFFSET IN WALL AND
CONNECT TO 2" VENT FROM BELOW.
8. 4" SS DOWN.
9. 2" VENT FROM BELOW, 2" VENT UP, 3" VTR.
10. 6" SD FROM SECONDARY ROOF DRAIN ABOVE.
11. 8" SECONDARY SD DOWN.
12. 1/2" CW DOWN THRU TRAP PRIMER VALVE,
DISCHARGE TO FLOOR DRAIN THRU AIR GAP.
13. 7' MIN ABOVE FINISHED FLOOR.
14. 1/2" CW TO 2 TRAP PRIMER VALVES.
15. 4" SD FROM PRD.
16. 4" SD @ 1/4" PER FOOT SLOPE MINIMUM.
17. 6" SD @ 1/8" PER FOOT SLOPE MINIMUM.
18. 1/2" COMPRESSED AIR DOWN TO HOSE REEL.
19. AIR COMPRESSOR AC-1. SINGLE STAGE BELT
DRIVE, 60 GALLON VERTICAL ASME TANK, 3 HP,
208V, SINGLE PHASE, 135 PSI MAX, 11.3 CFM @
90 PSI.
N
0 4' 8' 16'
1/8" = 1'-0"
SCALE 1/8" = 1'-0"
SECOND FLOOR PLUMBING PLAN1
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
1 ADDENDUM #1 03/03/2021
SEAL
050568
MECH EQUIP SHOWN FOR REF
ONLY, REFER MECH PLANS
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
RH
4930 MINUTEMAN WAY
CHARLOTTE, NC 28208
2000 East Lamar Blvd, Suite 600 Arlington, TX 76006 fsb-ae.com
Architecture Engineering Planning Frankfurt Short Bruza / Texas
817.588.3010
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
MAY 29, 2020
20180720
LLP
Pr oj ec tN o.
:F
JR
P
C ha rlo tte A
N G
B as e, C
D
IA
,N C
N or th C ar ol in a
A ir
N at io na lG ua rd C
-1
C on ve rs io n:
A dd
/A lte rS m al lT er m in al
B ld g
H :\P
R J\2018072 0\03-B
IM
\06-Plbg\80720_Plbg.rv t
5/27/2020 9:00: 15
AM
ROOF PLUMBING
P-104
LLP
WBB
WBB
SHEET KEYNOTES
GENERAL NOTES
1. INSTALL NEW PRIMARY ROOF DRAIN (PRD) TO
ATTACH TO EXISTING ROOF DRAIN LEADER
BELOW. FIELD-VERIFY LOCATION OF EXISTING
ROOF PENETRATION & COORDINATE WITH
EXISTING ROOFING WHICH IS TO REMAIN
(RECENTLY REPLACED).
2. INSTALL NEW SECONDARY ROOF DRAIN (SRD)
ADJACENT TO EACH EXISTING ROOF DRAIN.
COORDINATE WITH EXISTING ROOFING WHICH
IS TO REMAIN (RECENTLY REPLACED).
3. 3" VTR.
N
0 4' 8' 16'
1/8" = 1'-0"
SCALE 1/8" = 1'-0"
ROOF PLUMBING PLAN1
A. REFER TO P-001 FOR LEGEND, ABBREVIATIONS,
& GENERAL NOTES.
Frankfurt-Short-B document1 5801 Broadway Extension, S
Telephone (405) 840-2931 F
SEAL
1/2" TRAP PRIMER
SUPPLY, TOP
CONNECTION
DOMESTIC COLD WATER LINE (1 1/2" OR
SMALLER)
TRAP PRIMER VALVE. MUST BE ACCESSIBLE.
1/2" TRAP PRIMER LINE (TYP)
FLOOR DRAIN OR
FLOOR SINK
INSTALL MIN 1'-0" AFF
BALL VALVE. MUST BE ACCESSIBLE.
UNION
1. REFER TO PLANS FOR TRAP PRIMER LINES THAT DISCHARGE TO FLOOR
DRAIN THRU AIR GAP.
FLOOR SLAB
DEEP SEAL P-TRAP
TO TRAP PRIMER
CONNECTION ON FLOOR
DRAIN/FLOOR SINK
NOTES:1
VARIES; PROVIDE
EXTENSION PIECE
AS REQUIRED
FINISHED FLOOR
CLEANOUT COVER
COUNTER SUNK SCREW
CONCRETE SURFACE
OR FLOOR COVERING
AS REQUIRED
CAULKING
FERRULE
CLEANOUT PLUG
CLEANOUT
TEE
VARIES
STAINLESS STEEL
CLEANOUT COVER
COUNTER SUNK SCREW
COUNTER SUNK
BRASS PLUG
FINISHED WALL
HWR
HW
G TMV
NC
A
3/4"
1 1/2"
120°F
1 1/2"
3/4"
1 1/4"
PLUG VALVE
DRIP LEG
(LINE SIZE)
6" CONCRETE PAD
UNION
(TYP)
1 1/2"
BALANCING VALVE
BALANCING VALVE
FOR CIRCULATOR
AQUASTAT,
ON @ 105°F,
OFF @ 110°F
1 1/2"
140°F
CP1
FINISHED FLOOR
DWH
TO FLOOR DRAIN
P&T RELIEF VALVE
CW 1 1/2"
CHECK VALVE
120°F
3/4"
HB
THERMAL EXPANSION TANK, 5 GALLON VOLUME,
3.3 GALLON ACCEPTANCE, ASME SECTION VIII
CONSTRUCTION, BUTYL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .