This is a WebAIM Short Form Task Group Instruction (TGI) for shipboard maintenance work on the USS RAFAEL PERALTA (DDG-115). The document provides detailed instructions for installing a 1A Gas Turbine Module (GTM) intake moisture separator bonding strap, with a contractor work start date of 7/27/2026 and completion date of 9/4/2026.

The scope of work involves installing one bonding strap assembly on the blow-in door panel moisture separator in Intake Engine Room No. One Dirty Side (compartment 02-174-1-Q), located between frames 186 and 188 on the starboard side. The bonding strap is CRES Type-I material per MIL-DTL-24749C, and a boss on the 02 level deck plating is CRES 316L. The strap will be welded using Method 3 per Figure 11 of MIL-STD-1310 with a 1/8-inch fillet weld size and weld joint design PT1S.1 per MIL-STD-22D. The work requires accomplishment of gas turbine maintenance procedures and surface preparation requirements. SRF-JRMC will provide government-furnished materials and support services including crane and rigging, electrical and utility services, safety and gas-free inspections, and QA inspections. The material list includes four items: bonding strip assembly, screw, sleeve nut, and two insulation sheets, all ordered for contractor delivery. The work involves potential asbestos hazards and fire zone bulkhead access requiring nonflammable closure procedures per COMNAVSEASYSCOM guidance.

View the file

Other files

File Type Posted
TGI_38K6112304A01_c0v0_REV2.pdf PDF
TGI_38K6113701A01_c0v0_REV2.pdf PDF
TGI_38K6154101A01_c1v1_REV2.pdf PDF
TGI_38K6112320A01_c1v1_REV2.pdf PDF
TGI_38K6112001A01_c0v0_REV2.pdf PDF
Attachment II Price Proposal Sheet Generator v1.3.xlsx XLSX spreadsheet
TGI_38K6112301A01_c0v0_REV2.pdf PDF
TGI_38K6158301A01_c0v0_REV2.pdf PDF
Solicitation Amendment N6264926RA0360004 SF 30.pdf PDF
Solicitation Amendment N6264926RA0360003 SF 30.pdf PDF
TGI_38K6112301A01_c0v0_REV1.pdf PDF
TGI_38K6112305A01_c1v0_REV1.pdf PDF
TGI_38K6112304A01_c0v0_REV1.pdf PDF
TGI_38K6112316A01_c0v0_REV1.pdf PDF
TGI_38K6171101A01_c0v0_REV1.pdf PDF
TGI_38K6169901A01_c0v0_REV1.pdf PDF
TGI_38K6154101A01_c1v1_REV1.pdf PDF
7027318_53711_-_0001_ G_-_0001.pdf PDF
MP LM19-K6112303-ES01NA54_r3.pdf PDF
TGI_38K6112320A01_c1v1_REV1.pdf PDF
TGI_38K6112321A01_c0v0_REV1.pdf PDF
TGI_38K6112306A01_c0v1_REV1.pdf PDF
TGI_38K6112317A01_c0v0_REV1.pdf PDF
TGI_38K6112001A01_c0v0_REV1.pdf PDF
TGI_38K6158301A01_c0v0_REV1.pdf PDF
TGI_38K6165401A01_c0v0_REV1.pdf PDF
TGI_38K6186301A01_c0v0_rev1.pdf PDF
38K6112318A01_c2v2_REV2.pdf PDF
DWG 6218562_53711_-_0001_ R_-_0001.pdf PDF
Attachment IV Request for Information Form.pdf PDF
N6264926RA0360001 SF30.pdf PDF
TGI_38K6151101A01_c0v0.pdf PDF
TGI_38K6113702A01_c0v0.pdf PDF
TGI_38K6113601A01_c0v0.pdf PDF
TGI_38K6113602A01_c0v0.pdf PDF
TGI_38K6112303A01_c0v0.pdf PDF
TGI 38K6169901A01_c0v0.pdf PDF
TGI_38K6112316A01_c0v0.pdf PDF
TGI_38K6112306A01_c0v1.pdf PDF
TGI_38K6112321A01_c0v0.pdf PDF
Attachment VII QSAP.pdf PDF
Exhibit A CDRL - GFM.pdf PDF
Attachment V Source of Repair Instruction.pdf PDF
TGI_38K6154101T01_c0v0.pdf PDF
TGI_38K6113701A01_c0v0.pdf PDF
TGI_38K6112325A01_c0v0.pdf PDF
TGI 38K6171101A01_c0v0.pdf PDF
TGI_38K6112001A01_c0v0.pdf PDF
Attachment VI Warranty Tracking Information.pdf PDF
Attachment II Proposal Sheet Generator v1.2.xlsx XLSX spreadsheet
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUO

WebAIM Short Form TASK GROUP INSTRUCTION

21-JAN-2026 1543

20.15.6.0.9333 (July 2025) ICN: 38K6112304 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: #1A GTM INTAKE IT A 1 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-115 USS RAFAEL PERALTA K61 25131

CU PHASE TITLE: F/O – INSTALL 1A GTM INTAKE MOISTURE SEPARATOR BONDING STRAP, 02-174-1-Q

WORK CERTIFICATION SIGNATURES: DLs

COMPLETION OF WORK REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

RECORDS REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

FOUO Pg 1 of 5

ES01NA5U

PREPARING ACTIVITY: STATUS: APP WORKING STATUS:

PREPARED BY: CODE: PHONE: DATE:

WATANABE, YOSHIO 232 3152432375 29-NOV-2025

APPROVED BY: CODE: PHONE: DATE:

SENDA, HIDEMI 232 3152432496 29-NOV-2025

CONCURRED BY: CODE: PHONE: DATE:

REASON FOR WORK/NEED FOR CHANGE:

JCN:

ES01-NA5U

SPECIAL REQUIREMENTS:

CU PHASE DESCRIPTION:

ZONE MANAGER: ZONE: COMPARTMENT: LEVEL: FRAME: SIDE:

SAITO, KAZUNOBU VARIOUS U

JOB SUMMARY ID: TOT MAN HR.: TOT DUR: TOT JML COST: PLANNING ACCEPTANCE:

123A2104

1 SCOPE/PURPOSE:

1.1 Title: 1A Gas Turbine Module (GTM) Moisture Separator Bonding Strap; install

1.2 Location of Work:

1.2.1 Intake Engine Room No. One Dirty Side (02-174-1-Q)

1.2.2 Passage (01-118-1-L)

1.2.3 Deck Gear Locker (01-174-1-A)

1.3 Identification:

1.3.1 Quantity (One AY), Bonding Strap Assembly of Blow in Door Panel, Moisture Separator, Type-C in 02-174-1-Q, Frames between 186 and 188, Starboard

TGI Short Form

21-JAN-2026 1543

20.15.6.0.9333 (July 2025) (Continued) ICN: 38K6112304 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: #1A GTM INTAKE IT A 1 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-115 USS RAFAEL PERALTA K61 25131

CU PHASE TITLE: F/O – INSTALL 1A GTM INTAKE MOISTURE SEPARATOR BONDING STRAP, 02-174-1-Q

FOUO Pg 2 of 5

CU PHASE DESCRIPTION (Cont.)

Attachment Method: Method 3 on Figure 11 of Ref. No. 5, Welded Weld Joint Design of Boss: PT1S.1 of MIL-STD-22D Fillet Weld Size: 1/8 Inch Remarks: See Sketch Enclosure-01 for location detail

1.3.1.1 Quantity (One EA), Bonding Strap

Material: CRES, Type-I, Standard Size B of MIL-DTL-24749C

1.3.1.2 Quantity (One EA), Boss on 02 Level Deck Plating

Material: CRES 316L

1.4 Security Classification: None.

1.5 Initial Condition:

1.5.1 Potential Asbestos Hazard

1.6 Contractor work start date:

1.7 Contractor work completion date:

2 PROCEDURE:

2.1 Accomplish the requirements of Ref. No. 3.

(V)(G) “GAS TURBINE MAINTENANCE PROCEDURE”

2.2 Install each new bonding strap assembly listed in 1.3.1 in accordance with Ref. No. 4 and Ref. No. 5, using Ref. No. 6 for guidance.

2.2.1 Accomplish the requirements of 009-012 of Ref. No. One, including Table 2, Column(s) D, Lines One through 7.

2.3 Accomplish the requirements of 009-032 of Ref. No. One for each new and disturbed surface.

2.4 Notes:

2.4.1 Planner: Code 232 Y. Watanabe, 243-2375

Planner: Code 231B Y. Koyama, 243-9937 Engineer: Code 260 T, Ito, 243-4173

2.4.2 Work Integration Manager (WIM): Code 333 T. Yaginuma, 080-5419-0598

2.4.3 Work per this instruction involves cutting an access (or removal of a door) through a fire zone bulkhead, through the hull of the ship above the turn of the bilge, through ventilation components (ducting, plenums, etc.), or through any air-tight, fume-tight or watertight bulkheads normally used to control air flow in the event of a shipboard fire. A nonflammable closure is required in accordance with COMNAVSEASYSCOM MSG R 261400Z JUL 12. The closure, if not continuously in use, shall be staged near the access, readily visible and accessible, so that any emergency responder can install the closure to affect proper

Kouichi.Yoshida.ja Typewritten Text 7/27/2026

Kouichi.Yoshida.ja Typewritten Text 9/4/2026

21-JAN-2026 1543

20.15.6.0.9333 (July 2025) (Continued) ICN: 38K6112304 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: #1A GTM INTAKE IT A 1 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-115 USS RAFAEL PERALTA K61 25131

CU PHASE TITLE: F/O – INSTALL 1A GTM INTAKE MOISTURE SEPARATOR BONDING STRAP, 02-174-1-Q

FOUO Pg 3 of 5

CU PHASE DESCRIPTION (Cont.)

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

air flow onboard the ship.

2.4.4 WPC will copy the following pages in reference.

2.4.5 JCN ES01-NA5U is related to this TGI.

2.5 Government Furnished Material (GFM):

2.5.1 SRF-JRMC will provide GFM listed in the Material List.

2.6 SRF-JRMC will provide the following service work: (TGI No. 38K61123S02)

2.6.1 [C740] Crane and rigging service.

2.6.2 [X99E] Utility service, electrical.

2.6.3 [X99M] Provide utility service, including low pressure air supply, water supply, and steam supply.

2.6.4 [C106.1] Safety inspection for SRF-JRMC employees.

2.6.5 [C106.2] Gas free inspection for SRF-JRMC employees.

2.6.6 [C133] QA inspection for (G) symbol(s).

2.6.7 [C285] Inspection for (G) symbol(s).

21-JAN-2026 1543

20.15.6.0.9333 (July 2025) (Continued) ICN: 38K6112304 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: #1A GTM INTAKE IT A 1 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-115 USS RAFAEL PERALTA K61 25131

CU PHASE TITLE: F/O – INSTALL 1A GTM INTAKE MOISTURE SEPARATOR BONDING STRAP, 02-174-1-Q

FOUO Pg 4 of 5

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

1 NSI FY-26 NAVSEA Standard Items - 1 N 2 LI FY-26 Local Standard Items - ORG N

3 MP LM24-K6112304-

ES01NA5U

1A GTM INTAKE SYSTEM

FOD PROTECTION FOR

MOISTURE

SEPARATOR/BLOW-IN PANEL

BONDING

- Y ALL

4 DWG 300-7028673 SCHEDULE OF BONDING

AND GROUNDING

(INCLUDING CONDUCTIVE

CAULKING)

C Y SH:

5 MIL MIL-STD-1310 Shipboard Bonding, Grounding, and Other Techniques for EMP Mitigation and Safety

H N

6 DWG 150-7026722 UNIT STRL ARR DWG ASSY

UNIT 4310

H Y SH

3-

TASK NAME / TASK DESCRIPTION

SHOP/

TSD TS

SF

WC

CREW

# MHRS RWRK

2.1. FOD Protection Work 24HRs

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

100 M STRIP,EL, ORIG: C231B, Y.

KOYAMA 070-7787-2059

ORDERED FOR KTR

9B 5999 013438667 NA 4 N 53175503 1/EA

101 M SCREW,CA, ORIG: C231B, Y.

KOYAMA 070-7787-2059

ORDERED FOR KTR

9B 5305 014535741 NA 4 N 53175380 1/EA

MATERIAL REFERENCES

REF

NO.

DOCUMENT/DRAWING NUMBER DOCUMENT/DRAWING TITLE

REV

ICN: 38K6112304 KEY OP: A01

21-JAN-2026 1543

20.15.6.0.9333 (July 2025) (Continued) ICN: 38K6112304 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: #1A GTM INTAKE IT A 1 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-115 USS RAFAEL PERALTA K61 25131

CU PHASE TITLE: F/O – INSTALL 1A GTM INTAKE MOISTURE SEPARATOR BONDING STRAP, 02-174-1-Q

FOUO Pg 5 of 5

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

102 M NUT,SLEE, ORIG: C231B, Y.

KOYAMA 070-7787-2059

ORDERED FOR KTR

9B 5310 014231667 NA 4 N 53175506 1/EA

103 M INSULATI, ORIG: C231B, Y.

KOYAMA 070-7787-2059

ORDERED FOR KTR

9Q 5640 013713262 NA 4 N 53175510 1/SH

104 M INSULATI, ORIG: C231B, Y.

KOYAMA 070-7787-2059

ORDERED FOR KTR

9Q 5640 013713263 NA 4 N 53175513 1/SH

ATTACHMENT LIST

TITLE FILE NAME SAVED DATE

ENCLOSURE-01 38K6112304A01-Sketch.pdf 22-NOV-2025 0000

38K6112304A01

SKETCH

ENCLOSURE-01 SHEET 1 OF 1

LOCATION DETAIL OF BOSS FOR BONDING STRAP

FWD →

PLAN VIEW

02 LEVEL DECK WEATHER, FR 175 – 230, STBD

DETAIL 1-A

DETAIL 1-A

BOSS FOR BONDING STRAP ON 02 LEVEL DECK PLATING

BOSS