S02 - ATCH 26 - Joliet_CBOC_Issued_for_Bid_A1_Arch_Part_4.pdf
PDF 16 MB Posted
- Solicitation number
- 36C77623B0049
About this file
This file contains details of a cancelled federal contract opportunity for construction services. The Solicitation Number was 36C77623B0049 to provide Parking Expansion at the Joliet Community Based Outpatient Clinic for the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The opportunity was for construction work expanding the parking facilities at the Joliet CBOC medical center but has since been cancelled as indicated by the designation "Y" in the solicitation number. The file included architectural drawings and specifications but did not provide pricing terms or response deadlines given the cancellation of the opportunity.
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
Ex
GxGx
HxHx
JxJx
KxKx
K'x
Lx Lx
1x 4x 6x 9x 12x 13x 14x3x 5x 5.8x 8x 10x6.1x
Fx
15x9.5x1.2x
AE 304
AE 202
AE 301
A
3 4
B
New North Vestibule
NEW MASONRY EXTERIOR
FINISH AT NORTH EXTERIOR
WALLS
46' - 1" 22' - 5 1/2" 23' - 8 3/4"
42' - 0 3/4" 4' - 6" 41' - 7"
/4
601' - 8 1/2"
AE 302
7' - 10"
Lobby
8' - 0 1/2"
/2
20' - 7"
AE 202 4
AE 2022
LINE OF CANOPY ABOVE
601' - 8 1/2"
5' - 4" RO 5' - 10" 5' - 4" RO 6' - 2 1/4"
/4
/4
R O
R O
R O
AE 400
Elevator E-2
6' - 0" 6 1/4" 7' - 2"
13' - 8 1/2"
601' - 8 1/2"
2B
2B2B
AE 201
AE 2012
AE 201 3
AE 304
AE 303
601' - 8 1/2"
Engineering Space
NEW CAST IN PLACE
CONCRETE WALL
/2
601' - 8 1/2"
AE 304
A
B
5' - 9 1/4" 3' - 4 1/2" 11 1/4" 2' - 2 1/2" 4' - 4" 2' - 2 3/4"
1' - 0"
S2
S2
603' - 3 3/4"603' - 3 3/4"
T/ LOWER RETAINING WALL T/ LOWER RETAINING WALL
AE 205
AE 2058
ALIGN
Mach. Room 003A
A
AE 303
AE 303
D D D D
6" 5' - 4" 5' - 1" RO 7' - 10" 5' - 1" RO 7' - 10" 5' - 1" RO 5' - 4" 13' - 3" 5' - 1" RO 5' - 4" 6"
V A
R
IE
S
AE 2061
AE 206
AE 206
AE 206
6"
B B
A
A
A
7' - 2"
NEW RETAINING WALLS
9' - 0" 5' - 4" RO 5' - 6"
B
2 2 2
3 33 3
33 3
CG
CG
/4
Elev. Equip.
B003
Badge B004
Phone B002C
Home Based Primary Care
B002
Stair #2 S-2
Comm.
B005
Reception B001
Women's Restroom
B006
Men's Restroom
B008
HAC
B007
Copy Room B009
Phone B002A
Phone B002B
Phone B017
Phone B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Store B012
Corridor C0-2
Corridor C0-1
Elevator
EL-1
Mech.
B018
SYMBOLS LEGEND
Room name
KEYNOTE
ROOM NAME/NUMBER
0X
CENTERLINE
1i
PARTITION TAG: SEE SHEET AE 501, PARTITION
TYPES & DETAILS FOR MORE INFORMATION
SPOT FLOOR
ELEVATION
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
1-HOUR RATED CONSTRUCTION
2-HOUR RATED CONSTRUCTION
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
CONCRETE WALL
CMU - CONCRETE MASONRY UNITS
EXTERIOR RIGID INSULATION
CG
CORNER GUARD FINISH TAG: SEE SHEET
AI 601, FINISH PLANS & FINISH SCHEDULE
FOR DETAILED FINISHES INFORMATION
1i
STOREFRONT / WINDOW TAG: SEE SHEET
AE 602 WINDOW & STOREFRONT SCHEDULE
& DETAILS FOR SPECIFIC INFORMATION
DOOR TAG: SEE SHEET AE 601, DOOR
SCHEDULE & DETAILS SHEET FOR SPECIFIC
DOOR INFORMATION
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:5
P M
AE 100N
BASEMENT LEVEL PLAN NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/4" = 1'-0"
1 BASEMENT LEVEL PLAN - NORTH WALL
0 2' 4' 8'
ARCHITECTURAL KEYNOTES NEW WORK BASEMENT
KEY KEYNOTE
1 INFILL OPENING ONCE ELEVATOR IS INSTALLED. VERIFY WITH ELEVATOR MANUFACTURER.
2 PATCH AND REPAIR EXISTING GWB, METAL STUD FRAMING AT EACH NEW WINDOW & DOOR OPENING.
3 L6x4x3/8" GALVANIZED STEEL FRAME AT EACH WINDOW 'D', BASEMENT LEVEL
4 PREFINISHED METAL DOWN SPOUT
5 STEEL COLUMNS, WITH SPRAY APPLIED FIRE PROOFING, 2-HOUR
6 72" TURNING CIRCLE
7 48" x 48" DOOR APPROACH CLEARANCE
8 48" x 60" DOOR APPROACH CLEARANCE
9 54" x 60" DOOR APPROACH CLEARANCE
10 66" x 72" DOOR APPROACH CLEARANCE
Revisions Date
ISSUED FOR 30% SD 10/07/2022
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
GxGx
HxHx
JxJx
KxKx
K'xK'x
Lx Lx
1x 4x 6x 9x 12x 13x 14x3x 5x 5.8x 8x 10x6.1x
Fx
15x9.5x1.2x
AE 304
AE 202
A
3 4
B
42' - 0 3/4"
/4
4' - 6" 87' - 6 1/2"
22' - 5 1/2"
-H
O U
R
AE 302
Lobby
Alcove 102A
AE 202 4
AE 2022
AE 401
Elevator E-2
104A
ROOF OF NEW NORTH
VESTIBULE BELOW
CANOPY BELOW
Office
E Q
E Q
Vestibule
/4
8' - 9 3/4"
13' - 6 1/2" 4 1/4"
13' - 8 1/4"
/4
104B
Corridor C1-15A
2B
2B
2B
2B
2B
2B
2B
AE 201
AE 2012
AE 201 3
AE 304
AE 303
8' - 4 1/4"
2B
2B
2B
-H
O U
R
2-HOUR
ALIGN
AE 304
E Q
E Q
/4
M O
C M
U
/4
M O
N E
W C
M U
/4
C
D C
D D D
C
Storage 1116A
7' - 1 1/2"
/2
/2
/2
11" 2' - 2 1/2" 5"
7' - 6 1/2"
1116A
/4 " 45.00°
AE 208
AE 208
AE 208
AE 207
AE 207 6
AE 303
AE 303
AE 407
AE 407
ALIGN
A L
IG
N
D
4' - 0" 8' - 8" 6' - 2" 7' - 0 7/8"
/4
1' - 8 1/4" 4' - 0" 3' - 3 1/2" 1' - 4" 14' - 10" 1' - 4" 12' - 10 3/4" 6' - 7 5/8" 4' - 8 3/8"4' - 8 3/8"
AE 202
2' - 4" 1' - 4" 5' - 0" 2' - 6" 1' - 4" 2' - 4"
MO CMU
5' - 0"
MO CMU
5' - 0"
MO CMU
5' - 0"
MO CMU
5' - 0"
MO CMU
5' - 0"
MO CMU
5' - 0" 2' - 0"
2' - 7" 1' - 4" 2' - 8"
MO CMU
5' - 0"
4"
4"
4"
14' - 5"
C -1
B
CG
CG CG
FMS
Elevator
EL-1
Stair #2 S-2
Corridor C1-15
Rad Control
Dispensary
Diagnostic
Marco
Rad Room
Corridor C1-10
Clean Utility
Soiled Utility
Control
Sound Booth
Control
Sound Booth
Stor.
Elec. Clos.
1089A
Elec.
SYMBOLS LEGEND
Room name
KEYNOTE
ROOM NAME/NUMBER
0X
CENTERLINE
1i
PARTITION TAG: SEE SHEET AE 501, PARTITION
TYPES & DETAILS FOR MORE INFORMATION
SPOT FLOOR
ELEVATION
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
1-HOUR RATED CONSTRUCTION
2-HOUR RATED CONSTRUCTION
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
CONCRETE WALL
CMU - CONCRETE MASONRY UNITS
EXTERIOR RIGID INSULATION
CG
CORNER GUARD FINISH TAG: SEE SHEET
AI 601, FINISH PLANS & FINISH SCHEDULE
FOR DETAILED FINISHES INFORMATION
1i
STOREFRONT / WINDOW TAG: SEE SHEET
AE 602 WINDOW & STOREFRONT SCHEDULE
& DETAILS FOR SPECIFIC INFORMATION
DOOR TAG: SEE SHEET AE 601, DOOR
SCHEDULE & DETAILS SHEET FOR SPECIFIC
DOOR INFORMATION
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:0
P M
AE 101N
FIRST FLOOR PLAN NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/4" = 1'-0"
1 FIRST FLOOR LEVEL PLAN - NORTH WALL
ARCHITECTURAL KEYNOTES
KEY KEYNOTE
1 PATCH AND REPAIR EXISTING WALL AT LOCATION OF DEMOLISHED ROOF ACCESS LADDER
2 INFILL EXISTING CMU WALL , MATCH EXISTING BLOCK SIZE. PAINTED FINISH
3 ALIGN NEW CONSTRUCTION & FINISHES WITH EXISTING
4 REINSTALL EXISTING SINK, MILLWORK, AND COUNTER. SCRIBE BACKSPLASH TO NEW WALL.
5 NEW PREFABRICATED METAL ROOF ACCESS STAIR. PROVIDE LOCKABLE GATE.
6 JOINT LINE BETWEEN EXISTING CBOC AND NEW WORK
7 72" TURNING CIRCLE
8 48" x 48" DOOR APPROACH CLEARANCE
9 48" x 60" DOOR APPROACH CLEARANCE
10 54" x 60" DOOR APPROACH CLEARANCE
11 66" x 72" DOOR APPROACH CLEARANCE
0 2' 4' 8'
Revisions Date
ISSUED FOR 30% SD 10/07/2022
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
C
Ex
GxGx
HxHx
JxJx
KxKx
K'x K'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
A.E
15x9.5x1.2x
AE 304
AE 301
A
3 4
B
EXISTING BOILER PLANT
EXISTING ROOFING TO BE REPLACED,
16,997 SF
NEW CMU PARAPET
43' - 2" N E
W C
M U
P A
R A
P E
T
/4
2'
4' - 11 3/4" 87' - 2 1/2" NEW CMU PARAPET AT CBOC NORTH WALL
EXISTING AREAWAY AT 1ST FLOOR BELOW
0'
/4
45' - 10 3/4" 75' - 10 1/2"
8'
/4
/4
20' - 7"
CANOPY BELOW
628' - 10 1/2"
LINE OF EXISTING EXPANSION JOINT
BETWEEN NORTH & SOUTH
PORTION OF CBOC
EXISTING ROOF ACCESS
HATCH:
INFILL OPENING
22' - 5 1/2"
EXISTING ACCESS
STEPS FROM NORTH
ROOF UP TO SOUTH
ROOF
AE 302
ELEVATOR OVER RIDE
1/4" PER
FOOT
1/4" PER
FOOT
NEW ROOF STRUCTURE
33' - 0"
18' - 10 1/4"
E X
IS
T
IN
G
R O
O F
S T
R U
C T
U R
E T
O R
E M
A
IN
NEW NORTH VESTIBULE BELOW
ROOF DECK
R1
R1R1
R1R1
R8
R1
R1
R1 R1
R1
R2
R3
R3
R4
R4
R5
R5
R5
R5
R5
R5
R5 R5
R5
R5
R5
R7
R7
R7
R7
R7
R6
R6
R6
1 2
F
AE 407
/1 AE 102S
1/ 2"
AE 404
R9
R9
R9
R9
AE 102N
AD 105
AE 102N
R10
R10
R10
NEW DAVIT, 1,000 LB CAPACITY
R6
EXISTING ROOF STRUCTURE
EXISTING ROOF DRAIN
NEW MEMBRANE ROOF SYSTEM
NEW TAPERED INSULATION
EXISTING STRAINER, INSPECT.
REPLACE DAMAGED STRAINERS
EXISTING ROOF STRUCTURE
NEW OVER FLOW ROOF
DRAIN
NEW ROOF DRAIN
BODY
NEW MEMBRANE ROOF SYSTEM
NEW TAPERED INSULATION
NEW STRAINERS
ROOF LEGEND
NEW ROOFING SYSTEM
NEW CONSTRUCTION
NEW ROOF DRAIN WITH
OVERFLOW
OVERFLOW ROOF
DRAIN
EXISTING ROOF DRAIN
ROOF KEYNOTERn
EXISTING CONSTRUCTION
ROOF NORTH
628' - 10 1/2"
ROOF SOUTH
631' - 2 1/2"
Bx
EXISTING 2-HOUR
RATED FIRE BARRIER.
INSPECT FOR DAMAGE
EXISTING CMU PARAPET
EXISTING BRICK PARAPET
EXISTING CAST-IN-PLACE
CONCRETE ROOF STRUCTURE,
NORTH PORTION
EXISTING METAL DECK & CONCRETE
COMPOSITE ROOF, SOUTH PORTION
EXISTING STEEL BEAM
REINSTALL EXISTING EXPANSION JOINT
ASSEMBLY. REPLACE ANY MISSING OR
DAMAGED GASKETS.
NEW METAL FLASHING
NEW TPO ROOFING SYSTEM
CONTINUOUS FIBER CANT
TAPERED RIGID INSULATION
NEW TPO ROOFING SYSTEM,
WRAP OVER PARAPET
CONTINUOUS FIBER CANT
TAPERED RIGID INSULATION
2X PT WOOD BLOCKING
2X PT WOOD BLOCKING
NEW PREFINISHED METAL COPING
DRAPE TPO MEMBRANE ACROSS GAP TO
ALLOW FOR MOVEMENT
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
04/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:1
P M
AE 102N
ROOF PLAN - NORTH PORTION
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
1 ROOF NORTH
ROOF KEYNOTES
KEY KEYNOTE
R1 REPLACE EXISTING ROOF DRAIN IRON STAINERS. INSPECT EXISTING DRAIN BODY
FOR DAMAGE.
R2 NEW ROOF DRAIN AND OVER FLOW
R3 NEW SCUPPER & DOWNSPOUT, PREFINISHED
R4 ABANDONED CURB, VERIFY IN FIELD
R5 NEW PREFINISHED ALUMINUM COPING & PRESSURE TREATED WOOD BLOCKING
R6 SPRAY APPLIED FIRE PROOFING AT NEW STEEL FRAMING, 2-HOUR
R7 EXISTING MECHNICAL EQUIPMENT, SEE MECHNICAL SHEETS
R8 NEW ROOF DRAIN & LEADER CONNECTION
R9 WALK PADS BY ROOFING MANUFACTURER. CONFIRM FINAL LAYOUT WITH COR.
R10 NEW OVER-ROOF DUCTWORK
NOTES:
1. REMOVE EXISTING ROOF MEMBRANE, PROTECTION BOARD, INSULATION, FLASHING,
COPING, AND ACCESSORIES. PREPARE EXISTING ROOF DECK TO RECEIVE NEW ROOFING
SYSTEM PER ALL MANUFACTURER'S REQUIREMENTS.
2. NEW ROOFING SYSTEM SHALL BE FULLY ADHERED TPO MEMBRANE OVER POLYISO RIGID
INSULATION MINIMUM R-39 CONTINUOUS VALUE. ROOF INSULATION SHALL SLOPE TO
DRAINS A MINIMUM OF 1/4" PER FOOT.
3. PROVIDE CRICKETS AT ALL EQUIPMENT THAT DIRECT WATER AWAY FROM SUCH
ELEMENTS.
4. EXISTING PIPE PENETRATIONS (3" - 4" IN DIAMETER). PROVIDE PRICING FOR
18 SUCH PENETRATIONS AND A UNIT PRICE FOR ADDITIONAL PENETRATIONS.
1 1/2" = 1'-0"
3 EXISTING ROOF DRAIN
1 1/2" = 1'-0"
4 NEW ROOF DRAIN WITH OVER FLOW
Rn
0 1'½' 1 ½'
0 1'½' 1 ½'
0 4' 8' 16'
1" = 1'-0"
DETAIL SECTION AT NORTH-SOUTH EXISTING EXPANSION JOINT 2'0 1'1/2'
Revisions Date
ISSUED FOR 30% SD 10/07/2022
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
1x
1x
4x
4x
6x
6x
9x
9x
12x
12x 13x
14x
14x
Bx
Ax
A1x
B1x
C1x
D1x
E1x
3x 5x
A.E
15x1.2x
R 18' - 9 3/4"
EXISTING STANDING SEAM
METAL ROOF OVER
STAIR #1 - TO REMAIN
EXISTING CHILLERS ON EXPOSED STEEL
FRAME
ADD ALTERNATE:
REROOF EXISTING UPPER CANOPY
AT MAIN ENTRY:
2,163 SF
EXISTING LOW-SLOPED ON
ROTUNDA CLERESTORY, TO BE REROOFED
EXISTING ROOFING TO BE REPLACED,
16,654 SF
REPLACE EXISTING METAL COPING,
FINISH TO MATCH EXISTING, TYPICAL
1'
63' - 7 3/4" 58' - 4"
ROOF OF ROTUNDA STRUCTURE,
1,113 SF
EXISTING EXPANSION JOINT
BETWEEN NORTH & SOUTH
PORTION OF CBOC
631' - 2 1/2"
641' - 2 1/2" 633' - 6 1/2"
628' - 10 1/2"
EXISTING ACCESS
STEPS FROM NORTH
ROOF UP TO SOUTH
ROOF
4'
0" 2'
6'
" NORTH ROOF CBOC
SOUTH ROOF CBOC
HIGH POINT
R6 R6
R6 R6
R6
R5
R5
R5
R5
R5 R5 R5
R5
R5
R5
R5
LOWER CANOPY ROOF
230 SF
R7
R7
R7
R7
R7
R7
ROOF DECK
ROOF DECK
ROOF DECK
ROOF DECK
/1 AE 102N
R9
R9
R9
R9
R9
AE 102N
R10
R10
AD 105
AE 102N
R6
NEW ROOF OPENINGS
FOR DUCTWORK, SEE STRUCTURAL
DRAWINGS FOR NEW STEEL FRAMING
EXISTING ROOF STRUCTURE
EXISTING OVER FLOW ROOF
DRAIN
EXISTING ROOF DRAIN
NEW MEMBRANE ROOF SYSTEM
NEW TAPERED INSULATION
EXISTING STRAINER, INSPECT.
REPLACE DAMAGED STRAINERS
ROOF LEGEND
NEW ROOFING SYSTEM
NEW CONSTRUCTION
NEW ROOF DRAIN WITH
OVERFLOW
OVERFLOW ROOF
DRAIN
EXISTING ROOF DRAIN
ROOF KEYNOTERn
EXISTING CONSTRUCTION
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:2
P M
AE 102S
ROOF PLAN - SOUTH PORTION
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
ROOF SOUTH
ROOF KEYNOTES
KEY KEYNOTE
R1 REPLACE EXISTING ROOF DRAIN IRON STAINERS. INSPECT EXISTING DRAIN BODY
FOR DAMAGE.
R2 NEW ROOF DRAIN AND OVER FLOW
R3 NEW SCUPPER & DOWNSPOUT, PREFINISHED
R4 ABANDONED CURB, VERIFY IN FIELD
R5 NEW PREFINISHED ALUMINUM COPING & PRESSURE TREATED WOOD BLOCKING
R6 SPRAY APPLIED FIRE PROOFING AT NEW STEEL FRAMING, 2-HOUR
R7 EXISTING MECHNICAL EQUIPMENT, SEE MECHNICAL SHEETS
R8 NEW ROOF DRAIN & LEADER CONNECTION
R9 WALK PADS BY ROOFING MANUFACTURER. CONFIRM FINAL LAYOUT WITH COR.
R10 NEW OVER-ROOF DUCTWORK
NOTES:
1. REMOVE EXISTING ROOF MEMBRANE, PROTECTION BOARD, INSULATION, FLASHING,
COPING, AND ACCESSORIES. PREPARE EXISTING ROOF DECK TO RECEIVE NEW ROOFING
SYSTEM PER ALL MANUFACTURER'S REQUIREMENTS.
2. NEW ROOFING SYSTEM SHALL BE FULLY ADHERED TPO MEMBRANE OVER POLYISO RIGID
INSULATION MINIMUM R-39 CONTINUOUS VALUE. ROOF INSULATION SHALL SLOPE TO
DRAINS A MINIMUM OF 1/4" PER FOOT.
3. PROVIDE CRICKETS AT ALL EQUIPMENT THAT DIRECT WATER AWAY FROM SUCH
ELEMENTS.
4. EXISTING PIPE PENETRATIONS (3" - 4" IN DIAMETER). PROVIDE PRICING FOR
18 SUCH PENETRATIONS AND A UNIT PRICE FOR ADDITIONAL PENETRATIONS.
1 1/2" = 1'-0"
3 EXISTING ROOF DRAIN WITH OVER FLOW
0 1'½' 1 ½'
Rn
0 4' 8' 16'
Revisions Date
ISSUED FOR 30% SD 10/07/2022
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
Gx
Hx
Jx
Kx
K'x
Lx
1x
6x
12x 13x 14x
Cx
Bx
Ax
A1x
B1x
C1x
D1x
E1x
5.8x
8x
10x6.1x 15x9.5x1.2x
AE 103
New North
Vestibule
Lobby
Elevator E-2
Mach.
Room
003A
Engineering
Space
Ex
14x
Cx
Bx
Ax
A1x
Fx
15x
3' - 10"
3'
8" CMU INFILL WITH
BLOCK SEALER BOTH SIDES
8" CMU INFILL WITH
BLOCK SEALER BOTH SIDES
8" CMU INFILL WITH
BLOCK SEALER BOTH SIDES
8" CMU INFILL WITH
BLOCK SEALER BOTH SIDES
PREFINISHED SHEET METAL
ATTACHED TO THE EXISTING LOUVER
FRAMES AT THE SIDE OF THE DOOR AND
THE LOUVER ABOVE THE DOOR.
INFILL INTERIOR OPENING
WITH GYP BOARD & METAL
STUD FRAMING DIRECTLY
BEHIND EXISTING LOUVER
NEXT TO AND ABOVE THE DOOR
EXISTING AREAWAY
EXISTING AREAWAY
EXISTING DOOR
Elev. Equip.
B003
Badge
B004
Phone B002C
Home
Based
Primary
Care B002
Stair #2
S-2
Comm.
B005
Reception B001
Women's
Restroom
B006
Men's
Restroom
B008
HAC
B007 Copy Room
B009
Phone B002A
Phone B002B
Phone B017
Phone B016
A.O.
B015
Clinical
Nurse
Manager B014
Chief
Medical
Director B013
Patient
Education/Group
Room
B011
Patient
Education/Exercise
B010
Corridor C0-2
Corridor C0-3
Corridor C0-4
Corridor
C0-1
Mech.
B018
Elec.
B019
Gen Room B020
PAS Call
Center
B024
Education
Storage
B022
Nutrition
Services
B021
Main
Conference
Room
B023
Mech.
B025
Patient
Education/Group
Room
B033
Patient
Education/Group
Room
B032
Patient
Ed/Internet
Cafe
B031
Corridor
C0-6
Corridor C0-8
Corridor C0-7
Staff
Lounge
B042
Men's Staff
Locker
B036
Women's
Staff Locker
B034
Mech.
Corridor
C0-9
Corridor
C0-5
Mech.
B026
Elec.
B029
Elec.
B028
Comm B030
Facility
Storage
B041
EMS
B038
Building
Operator
B039
FMS
B040
Stair #1 S-1
Elevator
EL-1
Vending
Cooking
Classroom
0023A
Elec.
B019
Gen Room
B020
Mech.
B018
Mech.
B026
SYMBOLS LEGEND
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
1i
PARTITION TAG
Name Elevation
FLOOR/LEVEL ELEVATION
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
DOOR TAG - SEE SHEET
AE 601 DOOR SCHEDULE
FOR MORE INFORMATION
SPOT FLOOR
ELEVATION
A
WINDOW/STOREFRONT
TAG
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:2
P M
AE 103
MISCELLANEOUS NEW WORK
BASEMENT LEVEL
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/16" = 1'-0"
1 BASEMENT LEVEL MISC NEW WORK PLAN OVERALL
1/8" = 1'-0"
BASEMENT LEVEL ENLARGED AT EXISTING AREAWAY
0 8' 16' 32'
0 4' 8' 16'
Revisions Date
Hx
Jx
Kx
K'x
Lx
1x 13x 14x
Cx
Bx
Ax
A1x
B1x
C1x
D1x
E1x
5.8x 8x 10x6.1x
Fx
A.E
AE 104
AE 104
AC 403
MECHANICAL SHAFT
NEW 2-HOUR
RATED WALL
NEW DUCTWORK
SEE MECHANICAL SHEETS
+/- 8"
NOTE: ALIGN THIS FINISHED
FACE WITH EAST EDGE
OF NEW ROOF OPENING ABOVE
5' - 5 1/4"
DASHED LINES REPRESENT EDGES OF
NEW ROOF OPENINGS ABOVE
9x
C1x
EXISTING MECHANICAL SHAFT
NEW 2-HOUR
RATED WALL
NEW DUCTWORK
SEE MECHANICAL SHEETS
EXISTING COLUMN
NEW 2-HOUR
RATED WALL
NOTE: SPRAY-APPLIED FIRE PROOFING
REQUIRED FOR NEW STEEL FRAMING AT
NEW ROOF OPENINGS ABOVE, 2-HOUR
PM&R
Treatment 1112C
Toilet 1102A
Blood Draw 1114D
Women Health Exam
IT
Exam 5
Women Health Exam
Toilet 1047A
Men's Restroom
Women's Restroom
Treatment Room
FMS
Elevator
EL-1
Stair #2 S-2
Corridor C1-15
Rad Control
Dispensary
Storage 1116A
Diagnostic
Marco
Rad Room
Corridor
C1-13
Corridor C1-14
Corridor C1-11
Toilet
Toilet
HAC
Toilet 1112E
Soiled
Utility
1112A
Storage
1112B
PM&R
Treatment 1112D
Eye Tech
Visual
Fields
Treatment
1112C
Toilet
Toilet
1102A
Eye
Blood Draw
1114D
Eye
Blood Draw 1114C
Draw
Analysis
1114E
Toilet
1114F
Blood Draw
1114B
Eye
Eye
1-On-1
Room
1017C
Work Room 1017B
Supervisor
Office
1017A
Nurse
Triage
Exam 1
Exam 2
Nurse
Triage
Women
Health
Exam 3
IT
Telemed
Telemed
Closet
Telemed
Telemed
Toilet 1043ATelemed
Telemed
Exam 17
Exam 16
PACT 2
PACT 1
Exam 15
Exam 14
Exam 12
Exam 13
Exam 5
Women
Health
Exam 4
Toilet
Toilet 1047A
Men's
Restroom
Women's
Restroom
Treatment
Room
Toilet
Treatment
Room
CWT
CWT
Security
Wheelchair
Storage
Group
Treatment
Treatment
Room
Group
Treatment
Treatment
Room
Treatment
Room
Treatment
Room
Treatment
Room
Soiled
Utility
Exam 6
Exam 7
Exam 8
Exam 9
Clean
Storage
Room
B131
Exam10
Procedure 1
Shared
Gyno
Toilet
1059B
Toilet
Closet 1059A
Procedure 2
Exam 11
1065 Exam 19
Exam 18
PACT
PACT 4
Women
Health
Exam 21
Women
Health
Exam 20
Corridor C1-3
Telemed
HAC
Stair #1 S-1
Mobile Port
Waiting
Toilet
1068A
Toilet
1031A
Pharm. D
Pharm. D
Nutritionist
Teleretinal
Cardio/Pod
Shared
Office
Soiled
Utility
Clean Utility
Social
Worker
Shell Space
Corridor C1-10
Podiatry
Exam
Podiatry
Exam
Tech Work
Room
Audiology
Exam
Cast Room
Podiatry
Exam
Audiology
Exam
Oxygen
Evaluation
PFT Blood
Gas
Clean Utility
Soiled
Utility
Control
Sound
Booth
Control
Sound
Booth
1084Stor.
Corridor
C1-12
Corridor
C1-9
Corridor
Ambulance
Bay
C1-36
Corridor
C1-5
Corridor
C1-5
Corridor
C1-7
Corridor
C1-6
Corridor
C1-6
Corridor
C1-4
Corridor
C1-8
Corridor
C1-1
General
Waiting
Corridor
C1-2
Photo
Alcove
Reception
Equipment
Alcove
Nourishment
Alcove
Scale
Alcove
Meds
1065C
1065B
1065A
Elec. Clos.
1089A
Scale
Alcove
PAS
Elec.
1114 --
1114A
Boiler Plant
SYMBOLS LEGEND-PLAN
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
1i PARTITION TAG
1-HOUR RATED CONSTRUCTION
2-HOUR RATED CONSTRUCTION
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
SPOT FLOOR
ELEVATION
A
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
STOREFRONT / WINDOW TAG: SEE SHEET AE 602,
WINDOW & STOREFRONT SCHEDULE & DETAILS
FOR SPECIFIC INFORMATION
DOOR TAG: SEE SHEET AE 601, DOOR
SCHEDULE & DETAILS SHEET FOR SPECIFIC
DOOR INFORMATION
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:3
P M
AE 104
MISCELLANEOUS NEW WORK
FIRST FLOOR LEVEL
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/16" = 1'-0"
FIRST FLOOR LEVEL MISC NEW WORK PLAN
0 8' 16' 32'
0 1' 2' 4'
0 1' 2' 4'
1/2" = 1'-0"
FIRST FLOOR LEVEL NEW WORK ENLARGED PLAN OF SHAFT AT PM&R ROOM 1112
1/2" = 1'-0"
FIRST FLOOR LEVEL NEW WORK ENLARGED PLAN OF SHAFT
Revisions Date
Gx
Hx
JxJx
KxKx
K'xK'x
LxLx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
9.5x1.2x
New North Vestibule
Lobby
Elevator E-2
22' - 5 1/2" 23' - 8 3/4"
F2
F1
F2 F2
F3
F3
PL1
CANOPY
EM1
EM1
13' - 8 1/4"
F1
F1F1
F1
Engineering Space
Mach. Room 003A
AC 400
AC 400
F3
F3
F3
F3 F3
F3
F3
CEILING POCKET
CEILING POCKET
F3 F3 F3 F3 F3 F3
F3 F3
F3F3
F3 F3
F3F3 F3
F3
F3
F3 F3
F3
F3
F3 F3
F3
F3
F3 F3
F3
F3
F3 F3
F3
F3
F3
F3 F3 F3 F3
F3
F3
F3 F3
F3 F3
F3
F3
F3 F3 F3 F3 F3 F3 F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3 F3 F3 F3 F3 F3
F3
F3
F3
F3
F3
D2
D1 D1 D1
D2
D2 D2
D2 D2
D2
D2
D2
D2
D2
D2 D2D2
D2
D2
D2
D2
D2
D2
D2 D2 D2
D2 D2
D2
D2
D2
D2
D2D2
D2
D2
D2
D2 D2 D2
D2
D2
D2
D2
D2
D2
D2
D2
D2 D2
D2
D2D2
D2
D2
D2
D2
D2D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2D2D2
D2 D2
D2
D2
D2
D2 D2
D2
D2 D2
D2
D2
TL
/1 AC 100S
AFF
ACT 1
8' - 6"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"AFF
GB1
8' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 6"
AFF
ACT 3
8' - 5 1/2"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 3"
AFF
ACT 1
8' - 3"
AFF
ACT 1
8' - 3"
AFF
ACT 1
8' - 3"
AFF
ACT 1
8' - 3"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
GBX
8' - 0" AFF
GBX
8' - 0"
AFF
GBX
8' - 0"
AFF
GBX
8' - 0"
AFF
GBX
8' - 7 1/2"
AFF
GB1
8' - 0"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 3"
AFF
GB1
8' - 0"
BOTTOM OF FIXTURE
AT 9'-0" AFF, TYPICAL OF
(4) FOUR
BOTTOM OF FIXTURE
AT 9'-0" AFF, TYPICAL OF
(1) ONE
AFF
2 HR FIRE RATED SOFFIT
8' - 8"
AC 403
AC 403
AFF
GBX
7' - 11"
AC 501
EXISTING FOLDING PARTITION
TRACK ABOVE TO REMAIN
EXISTING FOLDING PARTITION
TRACK ABOVE TO REMAIN
AC 501
AC 501
AC 501
AC 501
AC 501
Elev. Equip.
B003
Badge B004
Phone B002C
Home Based Primary Care
B002
Stair #2 S-2
Comm.
B005
Reception B001
Women's Restroom
B006
Men's Restroom
B008
HAC
B007
Copy Room B009
Phone B002A
Phone B002B
Phone B017
Phone B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Patient Education/Group
Room B011
Patient Education/Exercise
B010
Store B012
Corridor C0-2
Corridor C0-3
Corridor C0-4
Corridor C0-1
Mech.
B018
Elec.
B019
Gen Room B020
PAS Call Center
B024
Education Storage
B022
Nutrition Services
B021
Main Conference
Room B023
Mech.
B025
Elevator
EL-1
Vending
Cooking Classroom
0023A
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
ACOUSTICAL CEILING TILE. PROVIDE
NEW GRID AND EDGE TRIM
GB1: NEW GYPSUM BOARD CEILING
OR SOFFIT.
D2 LED CAN LIGHTD2
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
LED EXIT SIGN
LED TRACK LIGHTTL
LED EMERGENCY LIGHT W/90 BATTERY
BACKUP
EM1
EX1
LED WALL MOUNTED SCONCE LIGHT
S1
S2
LED WALL MOUNTED UPLIGHT LIGHT,
SMALL
C1
LED DECORATIVE CEILING MOUNTED
FIXTURE
LED DECORATIVE CEILING MOUNTED
FIXTURE
R1
LIGHTING
CEILING TYPES
S3
LED WALL MOUNTED UPLIGHT LIGHT,
LARGE
CEILING TYPE &
CEILING ELEVATION8'-0" AFF
ACT1
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
LED ELEVATOR PIT LIGHTPL1
ACCESS PANELS - 2' X 2' TYPICAL
UNLESS OTHERWISE NOTED
ACT 2: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
NEW GRID AND EDGE TRIM
GBX: EXISTING GYPSUM BOARD
CEILING OR SOFFIT.
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:1
P M
AC 100N
REFLECTED CEILING PLAN -
BASEMENT NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
BASEMENT LEVEL REFLECTED CEILING PLAN
0 4' 8' 16'
CEILING SCHEDULE
TAG
MANUFACTURER
(BASIS OF DESIGN) DESCRIPTION COMMENTS
ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 3 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM, CLEAN ROOM TYPE
GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4
GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
1x 4x 6x 9x
12x 13x 14x
Ax
A1x
B1x
C1x
D1x
E1x
3x 5x
A.E
15x
1.2x
F3 F3 F3
F3 F3 F3 F3
F3F3F3F3
F3 F3 F3
F3F3F3
F3 F3 F3
F3 F3 F3 F3 F3 F3F3
F3
F3
F3
F3
F3 F3 F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3
F3F3F3
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3 F3 F3
F3F3F3
F3
F3 F3
D2
D2
D2
D2
D2 D2 D2
D2D2D2
D2 D2 D2
F3 F3 F3 F3
F3F3F3F3
F3 F3 F3 F3
F3F3
F3F3F3
F3 F3 F3
AFF
ACT 1
8' - 0" AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"AFF
ACT 1
8' - 0"
AFF
ACT 2
7' - 9"
AFF
ACT 2
7' - 9"
AFF
ACT 2
7' - 9"
AFF
ACT 2
7' - 9"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
/1 AC 101N
F3
AFF
GBX
7' - 9"
AFF
GBX
7' - 9"
AC 501
AC 501
AC 501
AC 501
AC 501
Patient Education/Group
Room B033
Patient Education/Group
Room B032
Patient Ed/Internet
Cafe B031
Corridor C0-6
Corridor C0-8
Corridor C0-7
Staff Lounge B042
Men's Staff Locker
B036
Women's Staff Locker
B034
Mech.
Corridor C0-9
Corridor C0-5
Mech.
B026
Elec.
B029
Elec.
B028
Comm B030
Facility Storage
B041
EMS
B038
Building Operator
B039
FMS
B040
Stair #1 S-1
Store B027
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
ACOUSTICAL CEILING TILE. PROVIDE
NEW GRID AND EDGE TRIM
GB1: NEW GYPSUM BOARD CEILING
OR SOFFIT.
D2 LED CAN LIGHTD2
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
LED EXIT SIGN
LED TRACK LIGHTTL
LED EMERGENCY LIGHT W/90 BATTERY
BACKUP
EM1
EX1
LED WALL MOUNTED SCONCE LIGHT
S1
S2
LED WALL MOUNTED UPLIGHT LIGHT,
SMALL
C1
LED DECORATIVE CEILING MOUNTED
FIXTURE
LED DECORATIVE CEILING MOUNTED
FIXTURE
R1
LIGHTING
CEILING TYPES
S3
LED WALL MOUNTED UPLIGHT LIGHT,
LARGE
CEILING TYPE &
CEILING ELEVATION8'-0" AFF
ACT1
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
LED ELEVATOR PIT LIGHTPL1
ACCESS PANELS - 2' X 2' TYPICAL
UNLESS OTHERWISE NOTED
ACT 2: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
NEW GRID AND EDGE TRIM
GBX: EXISTING GYPSUM BOARD
CEILING OR SOFFIT.
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:2
P M
AC 100S
REFLECTED CEILING PLAN -
BASEMENT SOUTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
BASEMENT LEVEL REFLECTED CEILING PLAN
0 4' 8' 16'
CEILING SCHEDULE
TAG
MANUFACTURER
(BASIS OF DESIGN) DESCRIPTION COMMENTS
ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 3 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM, CLEAN ROOM TYPE
GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4
GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
C
Gx
Hx
JxJx
KxKx
K'xK'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
9.5x1.2x
Office
Vestibule
Alcove 102A
Lobby
Elevator E-2
Corridor C1-15A
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3
F3
EM1
F3
F3
F3
F3
Storage 1116A
Stair #2 S-2
F3
F3F3F3F3
AC 401
F3
F3
F3 F3
F3 F3
F3
F3 F3
F3
F3
F3F3
F3
F3 F3
F3
F3
F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
D2
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3F3F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3F3F3
D2
D2 D2
D2
D2
D2 D2
D2
D2
D2 D2
D2 D2 D2 D2
D2 D2
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3
F3F3
F3F3
F3
F3
F3
F3
F3
F3F3F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3
F3 F3
F3
F3 F3
F3 F3
F3 F3
S2 S2 S2
S2
S2S2
S1
S1
S1
S1
S1
S1
S1
S1
S1 S1
S1
S1
1 2
F
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
9' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0" AFF
ACT 3
8' - 0" AFF
ACT 3
8' - 0" AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 3
8' - 0"
AFF
GB1
8' - 0"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 3
8' - 9"
AFF
ACT 3
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 3
9' - 0"
AFF
ACT 3
9' - 0"
AFF
ACT 3
9' - 0"
AFF
ACT 1
8' - 10"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
GBX
8' - 0"
AFF
ACT 2
8' - 8"
AFF
ACT 2
9' - 0"
AFF
ACT 2
8' - 8"
AFF
ACT 2
8' - 0"
AFF
ACT 2
8' - 8"
AFF
ACT 2
8' - 8"
AFF
ACT 2
8' - 0"
AFF
ACT 2
8' - 0"
AFF
ACT 1
8' - 6"
AFF
GBX
7' - 3"
AFF
GB1
7' - 3"
AFF
GBX
7' - 3"
AFF
GBX
8' - 0"
AFF
GB1
8' - 9"
NOTE: LAY-IN CEILING IS ABOVE THE
AUDIOLOGY SOUND BOOTHS
AFF
GBX
8' - 0"
Penthouse
Access
S-4
/1 AC 101S
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3
F3
F3
F3
AFF
ACT 1
9' - 0"
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
AFF
GBX
8' - 0"
AFF
GB1
8' - 0"
F3
F3
F3
AFF
GB1
8' - 0"
AFF
GBX
8' - 9"
AC 501
AC 501
AC 501
AC 5012
AC 501
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 1
8' - 6"
AFF
ACT 1
8' - 0"
FMS
Elevator
EL-1
Corridor C1-15
Rad Control
Dispensary
Diagnostic
Marco
Rad Room
Corridor C1-13
Corridor C1-14
Corridor C1-11
Toilet
Toilet
HAC
Toilet 1112E
Soiled Utility 1112A
Storage 1112B
PM&R
Treatment 1112D
Eye Tech
Visual Fields
Treatment 1112C
Toilet
Toilet 1102A
Eye
Blood Draw 1114D
Eye
Blood Draw 1114C
Draw Analysis
1114E
Toilet 1114F
Blood Draw 1114BEye
Mobile Port Waiting
Pharm. D
Pharm. D
Nutritionist
Teleretinal
Cardio/Pod Shared Office
Soiled Utility
Clean Utility
Social Worker
Shell Space
Corridor C1-10
Podiatry Exam
Podiatry Exam
Tech Work Room
Audiology Exam
Cast Room
Podiatry Exam
Audiology Exam
Oxygen Evaluation
PFT Blood Gas
Clean Utility
Soiled Utility
Control
Sound Booth
Control
Sound Booth
Stor.
Corridor C1-12
Corridor C1-9
Corridor
Ambulance Bay C1-36
Elec. Clos.
1089A
Scale Alcove
PAS
Elec.
1114A
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
ACOUSTICAL CEILING TILE. PROVIDE
NEW GRID AND EDGE TRIM
GB1: NEW GYPSUM BOARD CEILING
OR SOFFIT.
D2 LED CAN LIGHTD2
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
LED EXIT SIGN
LED TRACK LIGHTTL
LED EMERGENCY LIGHT W/90 BATTERY
BACKUP
EM1
EX1
LED WALL MOUNTED SCONCE LIGHT
S1
S2
LED WALL MOUNTED UPLIGHT LIGHT,
SMALL
C1
LED DECORATIVE CEILING MOUNTED
FIXTURE
LED DECORATIVE CEILING MOUNTED
FIXTURE
R1
LIGHTING
CEILING TYPES
S3
LED WALL MOUNTED UPLIGHT LIGHT,
LARGE
CEILING TYPE &
CEILING ELEVATION8'-0" AFF
ACT1
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
LED ELEVATOR PIT LIGHTPL1
ACCESS PANELS - 2' X 2' TYPICAL
UNLESS OTHERWISE NOTED
ACT 2: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
NEW GRID AND EDGE TRIM
GBX: EXISTING GYPSUM BOARD
CEILING OR SOFFIT.
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:3
P M
AC 101N
REFLECTED CEILING PLAN - 1ST
FLOOR NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
FIRST FLOOR LEVEL REFLECTED CEILING PLAN - NORTH PORTION
0 4' 8' 16'
CEILING SCHEDULE
TAG
MANUFACTURER
(BASIS OF DESIGN) DESCRIPTION COMMENTS
ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 3 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM, CLEAN ROOM TYPE
GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4
GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
1x 4x 6x 9x 12x 13x 14x
Ax
A1x
B1x
C1x
D1x
E1x
3x 5x
A.E
15x1.2x
F3
F3 F3 F3 F3 F3 F3 F3 F3 F3 F3
F3
F3
F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
S2 F3
F3
F3
F3F3
F3F3
F3F3
F3
F3
F3
F3
F3
F3
F3F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
D1
D1 D1 D1 D1
S2
S2
S2
S2S2
F3
F3
F3
F3
F3
F3
D1
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3F3 F3
F3
F3
F3
F3
F3 F3
F3F3
F3
F3 F3
F3
F3 F3
F3
F3 F3
F3 F3
F3
F3
D1
F3
F3
F3
F3
F3
F3
F3
F3F3
F3
F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
D1 D1 D1
F3
F3
S2 S2
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3 F3 F3F3
F3
F3
F3
F3
F3
F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3 F3
F3 F3 F3
F3 F3 F3 F3F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
D1
D1
R
R
R
R
R
R
R
R
R
R
R
R
R
R
C C
C C
C C
C C
D1 D1 D1 D1
D1 D1 D1D1D1D1
D1
D1
D1
D1S3
S3
S3
S3
F3 F3 F3 F3 F3 F3 F3 F3
F3
F3 F3
F3
F3
F3
D1 D1
F3
F3
S1 S1
S1
S1
S1
S1 S1
S1
S1
S1
S1
S1 S1
S1
S1
F3
F3
F3
F3
F3
AFF
GBX
10' - 0"
AFF
GBX
9' - 0"
AFF
GBX
10' - 0"
AFF
ACT 3
9' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 3
9' - 0"
AFF
GB1
8' - 0"
AFF
GB1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 10"
AFF
ACT 3
9' - 0"
AFF
ACT 1
9' - 0" AFF
ACT 1
9' - 0" AFF
ACT 1
9' - 0" AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 10"
AFF
ACT 1
8' - 10"
AFF
ACT 1
8' - 10"
AFF
ACT 1
8' - 10"AFF
ACT 1
8' - 10"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 1
8' - 9"
AFF
ACT 3
9' - 0"AFF
ACT 3
9' - 0"
AFF
ACT 1
9' - 0"AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
GBX
9' - 0"
AFF
GBX
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 6"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
GBX
8' - 6"
AFF
GBX
8' - 6"
AFF
GBX
8' - 6"
AFF
ACT 3
8' - 6"
AFF
ACT 3
8' - 6"
AFF
ACT 1
8' - 6"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
GBX
9' - 0"
AFF
GBX
9' - 0"
AFF
ACT 3
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 3
8' - 0" AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 3
9' - 0" AFF
ACT 1
9' - 0" AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
10' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
10' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 1
10' - 0"
AFF
ACT 1
8' - 10"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 1
9' - 0"
AFF
ACT 2
8' - 10"
AFF
ACT 2
8' - 10"AFF
ACT 2
8' - 10"
AFF
ACT 2
9' - 0" AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 2
8' - 10"
AFF
ACT 1
9' - 0"
AFF
GBX
10' - 3"
AFF
GBX
10' - 6"
AFF
GBX
10' - 0"
AFF
ACT 1
10' - 9"
AFF
GBX
8' - 0"
AFF
ACT 1
10' - 0"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
9' - 8"
AFF
GBX
8' - 0"
AFF
GB1
10' - 0"
AFF
GBX
11' - 8"
AFF
GBX
7' - 0"
AFF
GBX
7' - 2"
AFF
ACT 1
8' - 10"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
9' - 0" AFF
GBX
9' - 0"
AFF
GB1
9' - 0"
AFF
GB1
9' - 0"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GB1
8' - 9"
AFF
GBX
8' - 9"
AFF
GB1
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9" AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
AFF
GB1
9' - 0"
AFF
GBX
8' - 0"
AFF
ACT 1
10' - 9"
AFF
GBX
8' - 9"
/1 AC 101N
AFF
GBX
8' - 9"
AFF
GBX
8' - 9"
F3
F3
F3
F3
F3
F3
F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
AC 501
AC 501
AC 501
AC 501
Eye
1-On-1 Room 1017C
Work Room 1017B
Supervisor Office
1017A
Nurse Triage
Exam 1
Exam 2
Nurse Triage
Women Health Exam
IT
Telemed
Telemed
Closet
Telemed
Telemed
Toilet 1043A
Telemed
Telemed
Exam 17
Exam 16
PACT 2
PACT 1
Exam 15 1058 Exam 14
Exam 12
Exam 13
Exam 5
Women Health Exam
Toilet
Toilet 1047A
Men's Restroom
Women's Restroom
Treatment Room
Toilet
Treatment Room
CWT
CWT
Security
Wheelchair Storage
Group Treatment
Treatment Room
Group Treatment
Treatment Room
Treatment Room
Treatment Room
Treatment Room
Soiled Utility
Exam 6
Exam 7
Exam 8
Exam 9
Clean Storage
Exam10
Procedure 1 Shared Gyno
Toilet 1059B
Toilet
Closet 1059A
Procedure 2
Exam 11
Exam 19
Exam 18
PACT
PACT 4
Women Health Exam
Women Health Exam
Corridor C1-3
Telemed
HAC
Stair #1 S-1
Toilet 1068A
Toilet 1031A
Corridor C1-5
Corridor C1-5
Corridor C1-7
Corridor C1-6
Corridor C1-6
Corridor C1-4
Corridor C1-8
Corridor C1-1
General Waiting
Corridor C1-2
Photo Alcove
Reception
Equipment Alcove
Nourishment Alcove
Scale Alcove
Meds
1065C
1065B
1065A
Telemed
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
ACOUSTICAL CEILING TILE. PROVIDE
NEW GRID AND EDGE TRIM
GB1: NEW GYPSUM BOARD CEILING
OR SOFFIT.
D2 LED CAN LIGHTD2
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
LED EXIT SIGN
LED TRACK LIGHTTL
LED EMERGENCY LIGHT W/90 BATTERY
BACKUP
EM1
EX1
LED WALL MOUNTED SCONCE LIGHT
S1
S2
LED WALL MOUNTED UPLIGHT LIGHT,
SMALL
C1
LED DECORATIVE CEILING MOUNTED
FIXTURE
LED DECORATIVE CEILING MOUNTED
FIXTURE
R1
LIGHTING
CEILING TYPES
S3
LED WALL MOUNTED UPLIGHT LIGHT,
LARGE
CEILING TYPE &
CEILING ELEVATION8'-0" AFF
ACT1
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
LED ELEVATOR PIT LIGHTPL1
ACCESS PANELS - 2' X 2' TYPICAL
UNLESS OTHERWISE NOTED
ACT 2: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
NEW GRID AND EDGE TRIM
GBX: EXISTING GYPSUM BOARD
CEILING OR SOFFIT.
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
03/24/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:4
P M
AC 101S
REFLECTED CEILING PLAN - 1ST
FLOOR SOUTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
1 FIRST FLOOR LEVEL REFLECTED CEILING PLAN - SOUTH PORTION
0 4' 8' 16'
CEILING SCHEDULE
TAG
MANUFACTURER
(BASIS OF DESIGN) DESCRIPTION COMMENTS
ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 3 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM, CLEAN ROOM TYPE
GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4
GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
JxJx
KxKx
K'xK'x
LxLx
12x 13x 14x10x 15x
A A
3 4
B B
AE 302
New North Vestibule
Lobby
Elevator E-2
22' - 5 1/2" 23' - 8 3/4"
/4
/2 " F2
F1
F2 F2
F3
F3
PL1
CANOPY
EM1
EM1
E Q
E Q
13' - 8 1/4"
5' - 4 1/2" 10' - 9" 10' - 9" 5' - 4 1/2"
F1
F1 F1
F1
E Q
E Q
EQ EQ EQ EQ
E Q
E Q
E Q
E Q
Engineering Space
Mach. Room 003A
F3
F3
D2
D2D2D2 D2
D2
D2
7' - 8"
D1 D1D1
EXISTING GYP. BOARD
SOFFIT TO REMAIN
AFF
ACT 2
10' - 4"
AFF
ACT 2
9' - 0"
AFF
ACT 2
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
GB1
8' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
AFF
EC1
14' - 0"
BOTTOM OF FIXTURE
AT 9'-0" AFF, TYPICAL OF
(4) FOUR
BOTTOM OF FIXTURE
AT 9'-0" AFF, TYPICAL OF
(1) ONE
Stair #2 S-2
Comm.
B005
Elevator
EL-1
Reception B001
Gx
Hx
Jx
Kx
K'x
Lx
1x 4x 6x3x 5x 5.8x 8x6.1x1.2x
AE 304
AE 304
F3 F3 F3 F3 F3 F3
F3
F3
F3
F3
F3 F3
F3
D2
D2
D2D2
D2D2
D2D2
D2
1'
1'
1'
2' - 7"
2' - 7"
2' - 7"
CEILING POCKET
15' - 0"
CEILING POCKET
10' - 10"
CEILING POCKET
10' - 10"
C E
IL
IN
G P
O C
K E
T
C E
IL
IN
G P
O C
K E
T
6'
AFF
ACT 2
8' - 0" AFF
ACT 2
8' - 0"
AFF
ACT 2
8' - 0" AFF
ACT 1
8' - 0" AFF
ACT 1
8' - 0"AFF
ACT 1
8' - 0" AFF
ACT 1
8' - 0"
AFF
ACT 2
8' - 6"
AFF
ACT 1
8' - 6"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
ACT 2
9' - 0"
AFF
GBX
8' - 0"
AC 501
Elev. Equip.
B003
Badge B004
Home Based Primary Care
B002
Reception B001
Phone B002A
Phone B002B
Phone B017
Phone B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Corridor C0-2
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
ACOUSTICAL CEILING TILE. PROVIDE
NEW GRID AND EDGE TRIM
GB1: NEW GYPSUM BOARD CEILING
OR SOFFIT.
D2 LED CAN LIGHTD2
NEW COLUMN
GRID LINE
EXISTING COLUMN
GRID LINE
LED EXIT SIGN
LED TRACK LIGHTTL
LED EMERGENCY LIGHT W/90 BATTERY
BACKUP
EM1
EX1
LED WALL MOUNTED SCONCE LIGHT
S1
S2
LED WALL MOUNTED UPLIGHT LIGHT,
SMALL
C1
LED DECORATIVE CEILING MOUNTED
FIXTURE
LED DECORATIVE CEILING MOUNTED
FIXTURE
R1
LIGHTING
CEILING TYPES
S3
LED WALL MOUNTED UPLIGHT LIGHT,
LARGE
CEILING TYPE &
CEILING ELEVATION8'-0" AFF
ACT1
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
LED ELEVATOR PIT LIGHTPL1
ACCESS PANELS - 2' X 2' TYPICAL
UNLESS OTHERWISE NOTED
ACT 2: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
NEW GRID AND EDGE TRIM
GBX: EXISTING GYPSUM BOARD
CEILING OR SOFFIT.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
04/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:1
:4
P M
AC 400
REFLECTED CEILING ENLARGED
PLANS-BASEMENT LEVEL
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/4" = 1'-0"
2 BASEMENT LEVEL REFLECTED CEILING PLAN
CEILING SCHEDULE
TAG
MANUFACTURER
(BASIS OF DESIGN) DESCRIPTION COMMENTS
ACT 1 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 2 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM
ACT 3 USG 2X2 ACOUSTICAL LAY-IN CEILING SYSTEM, CLEAN ROOM TYPE
GB1 VARIES GYPSUM BOARD CEILING AND SOFFITS, PAINT P4
GBX VARIES EXISTING TO REMAIN PATCH AND REPAIR DAMAGE AS NEEDED
1/4" = 1'-0"
BASEMENT LEVEL REFLECTED CEILING PLAN
0 2' 4' 8'
0 2' 4' 8'
Revisions Date
ISSUED FOR 30% SD 10/07/2022
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID ADDENDUM 1 04/21/2023
Hx
JxJx
KxKx
K'xK'x
Lx
12x 13x 14x10x 15x
Office
Vestibule
Alcove 102A
Lobby
Elevator E-2
Corridor C1-15A
F3
F3
F3
F3
F3
F3
F3 F3
F3
F3
F3
EM1
F3
F3
F3
F3
Storage 1116A
Stair #2 S-2
4" 3'
4" 8' - 6"
F3
F3F3F3F3
NEW ROOF OPENING
F3
F3
F3
F3 F3
F3 D2D2D2D2
F3
AFF
ACT 2
8' - 6"
AFF
ACT 1
8' - 6"
AFF
ACT 1
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 1
8' - 0"
AFF
ACT 1
8' - 0"
AFF
ACT 2
8' - 0"
AFF
ACT 1
8' - 0"
Corridor C1-15
Dispensary
Elec.
Corridor C1-14
Diagnostic
RCP NOTES
A. SEE CEILING TYPES FOR LOCATION OF EXISTING GRID AND
TRIM TO REMAIN
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REINSTALL THE FOLLOWING (BUT NOT LIMITED TO) CEILING
MOUNTED DEVICES, ITEMS, & FIXTURES IN THEIR PREVIOUS
LOCATION:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. GYPSUM BOARD SOFFITS & CEILINGS: REPAIR ANY DAMAGE
AS A RESULT OF ADJACENT GENERAL DEMOLITION OR
CONSTRUCTION WORK UNDER THIS CONTRACT.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
IN INDICATED LOCATIONS.
F3 2X2 LED TROFFER LIGHT
F1 2X4 LED TROFFER LIGHT,
SUSPENDED
D1 WATERPROOF LED CAN LIGHT
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
ACT 1: NEW 2X2 LAY-IN
ACOUSTICAL CEILING TILE.
EXISTING GRID AND EDGE TRIM TO
REMAIN.
EC1: EXPOSED CONSTRUCTION
RCP SYMBOLS LEGEND
NEW WORK
F1
F3
D1
EXISTING 2X4 LED TROFFER LIGHTEX
ACT 3: NEW 2X2 LAY-IN CLEAN ROOM
A…
This is the start of the file's text. The full file is on GovTribe.