This document contains ceiling diagrams and reflected ceiling plans for the parking expansion project at the Joliet Community Based Outpatient Clinic. The project involves replacing ceiling tiles, grids, and trim throughout basement and first floor areas, including lay-in ceilings, gypsum board ceilings, and cleanroom ceilings. Replacement work will be performed in the new north vestibule, elevator lobbies, corridors, mechanical rooms, stairs, treatment rooms, exam rooms, offices, waiting areas, restrooms, and other occupied spaces. Demolition of existing ceilings is noted, along with the scope of work to remove and reinstall devices as necessary. Product data is provided for new ceiling components. The Department of Veterans Affairs Technology Acquisition Center Austin issued the related cancelled solicitation for construction services for the parking expansion.
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ex
Gx
Hx
JxJx
KxKx
K'xK'x
LxLx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
9.5x1.2x
/1 AD 110S
Elev. Equip.
B003
Badge B004
Phone B002C
Home Based Primary Care
B002
Stair #2 S-2
Comm.
B005
Reception B001
Women's Restroom
B006
Men's Restroom
B008
HAC
B007
Copy Room B009
Phone B002A
Phone B002B
Phone B017
Phone B016
A.O.
B015
Clinical Nurse Manager
B014
Chief Medical Director
B013
Patient Education/Group
Room B011
Patient Education/Exercise
B010
Store B012
Corridor C0-2
Corridor C0-3
Corridor C0-4
Corridor C0-1
Mech.
B018
Elec.
B019
Gen Room B020
PAS Call Center
B024
Education Storage
B022
Nutrition Services
B021
Main Conference
Room B023
Mech.
B025
Elevator
EL-1
Vending
Cooking Classroom
0023A
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
RCP SYMBOLS LEGEND
DEMOLITION
GYPSUM BOARD
2X4 LED TROFFER LIGHT TO BE
REMOVED
EXPOSED CONSTRUCTION
CAN LIGHT TO BE REMOVED
2X2 LED TROFFER LIGHT TO BE
REMOVED
EXISTING COLUMN
GRID LINE
CEILING MOUNTED EXIT SIGN TO BE
REMOVED
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
EXISTING CONSTRUCTION TO BE
DEMOLISHED
RCP DEMOLITION NOTES
A. LAY-IN CEILING TILES ARE TO BE REPLACE THROUGHOUT THE
BUILDING.
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE
FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED
DEVICES, ITEMS, & FIXTURES:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.
REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL
DEMOLITION WORK.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
UNLESS NOTED OTHERWISE.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
07/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:0 :4
P
M
AD 110N
REFLECTED
CEILING PLAN-BASEMENT
NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
1 BASEMENT LEVEL REFLECTED CEILING PLAN
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 2 07/21/2023
New North Vestibule
Lobby
Elevator E-2
22' - 5 1/2" 23' - 8 3/4"
F2A F2A F2A
F3
F3
CANOPY
EM1
EM1
13' - 8 1/4"
Engineering Space
Mach. Room 003A
AC 400
D1 D1 D1
F3A
F3AF3AF3A
AFF
ACT 2
8' - 0"
AFF
EC1
14' - 0"
AFF
GB1
8' - 0"
BOTTOM OF FIXTURE
AT 9'-0" AFF, TYPICAL OF
(1) ONE
F2A
F2A
F1A F1A
F1AF1AF1A
F7
Stair #2 S-2
Comm.
B005
ACT2:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM
ACT3:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM - CLEANROOM TILE
ACT1:
REPLACE LAY-IN CEILING TILE ONLY.
EXISTING GRID & TRIM TO REMAIN
CEILINGS LEGEND
CEILING DIAGRAM
NOTE: IN ROOMS & AREAS TO RECEIVE COMPLETE NEW CEILING SYSTEM, NEW CEILING SHALL BE PLACED AT SAME
ELEVATION AS EXISTING.
B. SECTION 09 51 00, ACOUSTICAL CEILINGS
Finish Code Component Color Pattern Manufacturer Mfg Name/No.
ACT2 & ACT3 Exposed Suspension
System
White USG Donn DX 15/16”
ACT1 & ACT2 Acoustic Tile White (2x2) USG Mars 86785HRC SLT
Edge
ACT3 Acoustic Tile
Cleanroom Type
White (2x2) USG Mars 86169CR
Square Edge i_dic Snapshot i_dic Snapshot i_dic Snapshot i_dic Snapshot i_dic Snapshot i_dic Snapshot i_dic Rectangle i_dic Rectangle i_dic Rectangle i_dic Rectangle i_dic Rectangle
Rectangle
1x 4x 6x 9x
12x 13x 14x
Bx
Ax
A1x
B1x
C1x
D1x
E1x
3x 5x
A.E
15x
1.2x
/1 AD 110N
Patient Education/Group
Room B033
Patient Education/Group
Room B032
Patient Ed/Internet
Cafe B031
Corridor C0-6
Corridor C0-8
Corridor C0-7
Staff Lounge B042
Men's Staff Locker
B036
Women's Staff Locker
B034
Mech.
Corridor C0-9
Corridor C0-5
Mech.
B026
Elec.
B029
Elec.
B028
Comm B030
Facility Storage
B041
EMS
B038
Building Operator
B039
FMS
B040
Stair #1 S-1
Store B027
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
RCP SYMBOLS LEGEND
DEMOLITION
GYPSUM BOARD
2X4 LED TROFFER LIGHT TO BE
REMOVED
EXPOSED CONSTRUCTION
EXISTING LAY-IN ACOUSTICAL
CEILING TILE TO BE REMOVED
UNLESS NOTED OTHERWISE
CAN LIGHT TO BE REMOVED
2X2 LED TROFFER LIGHT TO BE
REMOVED
EXISTING COLUMN
GRID LINE
CEILING MOUNTED EXIT SIGN TO BE
REMOVED
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
EXISTING CONSTRUCTION TO BE
DEMOLISHED
RCP DEMOLITION NOTES
A. LAY-IN CEILING TILES ARE TO BE REPLACE THROUGHOUT THE
BUILDING.
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE
FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED
DEVICES, ITEMS, & FIXTURES:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.
REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL
DEMOLITION WORK.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
UNLESS NOTED OTHERWISE.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
07/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:0 :4
P
M
AD 110S
REFLECTED
CEILING PLAN-BASEMENT
SOUTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
1 BASEMENT LEVEL REFLECTED CEILING PLAN
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 2 07/21/2023
ACT2:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM
ACT3:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM - CLEANROOM TILE
ACT1:
REPLACE LAY-IN CEILING TILE ONLY.
EXISTING GRID & TRIM TO REMAIN
CEILINGS LEGEND
CEILING DIAGRAM
NOTE: IN ROOMS & AREAS TO RECEIVE COMPLETE NEW CEILING SYSTEM, NEW CEILING SHALL BE PLACED AT SAME
ELEVATION AS EXISTING.
B. SECTION 09 51 00, ACOUSTICAL CEILINGS
Finish Code Component Color Pattern Manufacturer Mfg Name/No.
ACT2 & ACT3 Exposed Suspension
System
White USG Donn DX 15/16”
ACT1 & ACT2 Acoustic Tile White (2x2) USG Mars 86785HRC SLT
Edge
ACT3 Acoustic Tile
Cleanroom Type i_dic Rectangle i_dic Rectangle i_dic Rectangle i_dic Rectangle
Ex
Gx
Hx
JxJx
KxKx
K'xK'x
Lx
1x 4x 6x 9x 12x 13x 14x
Cx
Bx
Ax
3x 5x 5.8x 8x 10x6.1x
Fx
A.E
15x
15y
9.5x1.2x
/1 AD 111S
GWB CEILING TO BE DEMOLISHED -
CONTRACTOR TO SALVAGE
SUSPENSION SYSTEM IF POSSIBLE
REMOVE EXISTING GWB AT EXISTING LADDER
FMS
Elevator
EL-1
Stair #2 S-2
Corridor C1-15
Rad Control
Dispensary
Diagnostic
Marco
Rad Room
Corridor C1-13
Corridor C1-14
Corridor C1-11
Toilet
Toilet
HAC
Toilet 1112E
Soiled Utility 1112A
Storage 1112B
PM&R
Treatment 1112D
Eye Tech
Visual Fields
Treatment 1112C
Toilet
Toilet 1102A
Eye
Blood Draw 1114D
Eye
Blood Draw 1114C
Draw Analysis
1114E
Toilet 1114F
Blood Draw 1114B
Eye
Mobile Port Waiting
Pharm. D
Pharm. D
Nutritionist
Teleretinal
Cardio/Pod Shared Office
Soiled Utility
Clean Utility
Social Worker
Shell Space
Corridor C1-10
Podiatry Exam
Podiatry Exam
Tech Work Room
Audiology Exam
Cast Room
Podiatry Exam
Audiology Exam
Oxygen Evaluation
PFT Blood Gas
Clean Utility
Soiled Utility
Control
Sound Booth
Control
Sound Booth
Stor.
Corridor C1-12
Corridor C1-9
Corridor
Ambulance Bay C1-36
Elec. Clos.
1089A
Scale Alcove
PAS
Elec.
1114A
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
RCP SYMBOLS LEGEND
DEMOLITION
GYPSUM BOARD
2X4 LED TROFFER LIGHT TO BE
REMOVED
EXPOSED CONSTRUCTION
EXISTING LAY-IN ACOUSTICAL
CEILING TILE TO BE REMOVED
UNLESS NOTED OTHERWISE
CAN LIGHT TO BE REMOVED
2X2 LED TROFFER LIGHT TO BE
REMOVED
EXISTING COLUMN
GRID LINE
CEILING MOUNTED EXIT SIGN TO BE
REMOVED
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
EXISTING CONSTRUCTION TO BE
DEMOLISHED
RCP DEMOLITION NOTES
A. LAY-IN CEILING TILES ARE TO BE REPLACE THROUGHOUT THE
BUILDING.
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE
FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED
DEVICES, ITEMS, & FIXTURES:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.
REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL
DEMOLITION WORK.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
UNLESS NOTED OTHERWISE.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
07/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:0 :5
P
M
AD 111N
REFLECTED
CEILING PLAN-1ST FLOOR
NORTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
FIRST FLOOR LEVEL DEMO RCP - NORTH PORTION
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 2 07/21/2023
O
Alcove 102A
Lobby
Elevator E-2
Corridor C1-15A
F2A
F2A
F2A
F2A
F2AF2A
F2A
F2A
F2A
EM1
F2A
F2A
F2A
F2A
F2A
F2A
F2A
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"
AFF
ACT 2
8' - 6"AFF
ACT 2
8' - 6"F4
F4
Corridor C1-15
Elec.
ACT1:
REPLACE LAY-IN CEILING TILE ONLY.
EXISTING GRID & TRIM TO REMAIN
ACT2:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM
ACT3:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM - CLEANROOM TILE
SUSPENDED GYP. BOARD
CEILING:
REPLACE GYPSUM BOARD CEILINGS
(OR PORTIONS OF GYP. BOARD CEILINGS) FOR
INSTALLATION OF NEW MECHANICAL SYSTEMS.
SALVAGE SUSPENSION SYSTEM IF POSSIBLE
CEILINGS LEGEND
CEILING DIAGRAM
NOTE: IN ROOMS & AREAS TO RECEIVE COMPLETE NEW CEILING SYSTEM, NEW CEILING SHALL BE PLACED AT SAME
ELEVATION AS EXISTING.
B. SECTION 09 51 00, ACOUSTICAL CEILINGS
Finish Code Component Color Pattern Manufacturer Mfg Name/No.
ACT2 & ACT3 Exposed Suspension
System
White USG Donn DX 15/16”
ACT1 & ACT2 Acoustic Tile White (2x2) USG Mars 86785HRC SLT
Edge
ACT3 Acoustic Tile
Cleanroom Type i_dic Rectangle i_dic Rectangle i_dic Rectangle i_dic Rectangle
1x 4x 6x 9x 12x 13x 14x
Ax
A1x
B1x
C1x
D1x
E1x
3x 5x
A.E
15x1.2x
/1 AD 111N
Eye
1-On-1 Room 1017C
Work Room 1017B
Supervisor Office
1017A Nurse Triage
Exam 1
Exam 2 1035 Nurse Triage
Women Health Exam
IT
Telemed
Telemed
Closet
Telemed
Telemed
Toilet 1043A
Telemed 1039Telemed
Exam 17
Exam 16
PACT 2
PACT 1
Exam 15
Exam 14
Exam 12
Exam 13
Exam 5
Women Health Exam
Toilet
Toilet 1047A
Men's Restroom
Women's Restroom
Treatment Room
Toilet
Treatment Room
CWT
CWT
Security
Wheelchair Storage
Group Treatment
Treatment Room
Group Treatment
Treatment Room
Treatment Room
Treatment Room
Treatment Room
Soiled Utility
Exam 6
Exam 7
Exam 8
Exam 9
Clean Storage
Exam10
Procedure 1 Shared Gyno
Toilet 1059B
Toilet
Closet 1059A
Procedure 2
Exam 11
Exam 19
Exam 18
PACT
PACT 4
Women Health Exam
Women Health Exam
Corridor C1-3
Telemed
HAC
Stair #1 S-1
Toilet 1068A
Toilet 1031A
Corridor C1-5
Corridor C1-5
Corridor C1-7
Corridor C1-6
Corridor C1-6
Corridor C1-4
Corridor C1-8
Corridor C1-1
General Waiting
Corridor C1-2
Photo Alcove
Reception
Equipment Alcove
Nourishment Alcove
Scale Alcove
Meds
1065C
1065B
1065A
Telemed
EXISTING CONSTRUCTION TO REMAIN
Room name
KEYNOTEX
ROOM NAME/NUMBER
0X
CENTERLINE
RCP SYMBOLS LEGEND
DEMOLITION
GYPSUM BOARD
2X4 LED TROFFER LIGHT TO BE
REMOVED
EXPOSED CONSTRUCTION
EXISTING LAY-IN ACOUSTICAL
CEILING TILE TO BE REMOVED
UNLESS NOTED OTHERWISE
CAN LIGHT TO BE REMOVED
2X2 LED TROFFER LIGHT TO BE
REMOVED
EXISTING COLUMN
GRID LINE
CEILING MOUNTED EXIT SIGN TO BE
REMOVED
NOTE: SEE SHEET GI 003 FOR COMPLETE LIST OF SYMBOLS & ABBREVIATIONS
EXISTING CONSTRUCTION TO BE
DEMOLISHED
RCP DEMOLITION NOTES
A. LAY-IN CEILING TILES ARE TO BE REPLACE THROUGHOUT THE
BUILDING.
B. ROOM LIGHTS ARE TO BE REPLACED. SEE ELECTRICAL
SHEETS FOR FIXTURE INFORMATION.
C. REMOVE (AND PRESERVE FOR REINSTALLATION) THE
FOLLOWING (BUT NOT LIMITED TO) CEILING MOUNTED
DEVICES, ITEMS, & FIXTURES:
a. SMOKE & HEAT DETECTORS
b. CAMERAS
c. WI-FI ANTENNAS
d. SPEAKERS
e. MIRRORS
f. EMERGENCY LIGHTS
g. NURSE CALL LIGHTS
h. SIGNS
i. DIFFUSERS AND GRILLES
j. VISUAL FIRE ALARMS
k. ARTWORK
l. SPRINKLER HEAD TRIM RINGS
m. CURTAIN TRACKS
n. MED GAS LINE ESCUTCHEONS
o. CEILING MOUNTED EXAM LIGHTS
D. PRESERVE EXISTING GYPSUM BOARD SOFFITS & CEILINGS.
REPAIR ANY DAMAGE AS A RESULT OF ADJACENT GENERAL
DEMOLITION WORK.
E. PRESERVE AND PROTECT EXISTING CEILING GRID AND TRIM
UNLESS NOTED OTHERWISE.
444 W. Lake St. Suite 1700 Chicago, IL 60606
312.583.7023 www.virtualenergysolutions.com
Joliet Community Based Outpatient Clinic 1201 Eagle Street Joliet, Illinois 60432
Drawing No.
Scale:
Date:
Checked By:Drawn By:Designed By:
Drawing Title:
Contract No.
File No.Building No.
Client Project No.
Project Title:Approved: Chief, failites Management Services
Approved: Medical Center Director
Approved:
Approved: Location:
VES Project Number: 191006
AS NOTED
VA JOLIET CBOC
JOLIET, ILLINOIS
578-371 36C25219D0020
N O
T F
O R
C O
N S
T R
U C
T
IO
N
© 2020 Virtual Energy Solutions, INC.
07/21/2023
B
IM
/2
-M
A T
O C
-P a rk in g E x p a n s io n a t J o lie t C
B O
C
-3
/2
J o lie t
C B
O C
P a rk in g E x p a n s io n V
E S
A rc h
.r v t
-0
-2
:0 :5
P
M
AD 111S
REFLECTED
CEILING PLAN-1ST FLOOR
SOUTH
PARKING EXPANSION AT
JOLIET CBOC
GCGIDGID
1/8" = 1'-0"
1 FIRST FLOOR LEVEL DEMO RCP - SOUTH PORTION
0 4' 8' 16'
Revisions Date
ISSUED FOR 60% DD 12/30/2022
ISSUED FOR 90% PRICING 02/02/2023
ISSUED FOR 90% CD 02/10/2023
ISSUED FOR 100% CD 03/07/2023
ISSUED FOR BID 03/24/2023
ISSUED FOR BID ADDENDUM 2 07/21/2023
ACT2:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM
ACT3:
REPLACE LAY-IN CEILING SYSTEM:
TILE, GRID, & TRIM - CLEANROOM TILE
SPECIAL NOTE -
IT ROOM 1014:
WORK IN THIS ROOM IS UNDER SEPARATE CONTRACT.
COORDINATE ABOVE CEILING WORK WITH COR.
ACT1:
REPLACE LAY-IN CEILING TILE ONLY.
EXISTING GRID & TRIM TO REMAIN
SUSPENDED GYP. BOARD
CEILING:
REPLACE GYPSUM BOARD CEILINGS
(OR PORTIONS OF GYP. BOARD CEILINGS) FOR
INSTALLATION OF NEW MECHANICAL SYSTEMS.
SALVAGE SUSPENSION SYSTEM IF POSSIBLE
CEILINGS LEGEND
CEILING DIAGRAM
NOTE: IN ROOMS & AREAS TO RECEIVE COMPLETE NEW CEILING SYSTEM, NEW CEILING SHALL BE PLACED AT SAME
ELEVATION AS EXISTING.
B. SECTION 09 51 00, ACOUSTICAL CEILINGS
Finish Code Component Color Pattern Manufacturer Mfg Name/No.
ACT2 & ACT3 Exposed Suspension
System
White USG Donn DX 15/16”
ACT1 & ACT2 Acoustic Tile White (2x2) USG Mars 86785HRC SLT
Edge
ACT3 Acoustic Tile
Cleanroom Type i_dic Rectangle i_dic Rectangle i_dic Rectangle i_dic Rectangle
| AD 110N - DEMOLITION REFLECTED CEILING PLAN-BASEMENT NORTH |
| AD 110S - DEMOLITION REFLECTED CEILING PLAN-BASEMENT SOUTH |
| AD 111N - DEMOLITION REFLECTED CEILING PLAN-1ST FLOOR NORTH |
| AD 111S - DEMOLITION REFLECTED CEILING PLAN-1ST FLOOR SOUTH |
File details come from the government source that posted it. Updated .