RFP W-10878158 Appendix C - Adept File Naming.pdf
PDF 182 KB Posted
- Solicitation number
- 70Z04722R43000001
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Base San Juan Hurricane Rebuild West and Central Locations
Project No. 10878158 USCG Base San Juan, PR
Appendix C Adept File Naming
BASE SAN JUAN REBUILD WEST AND CENTRAL PROJECT #10878158
SITES: BASE SUPPORT WEST AND CENTRAL LOCATIONS
SAN JUAN, PUERTO RICO
FDCC’s
ADEPT File Naming
Published by:
FDCC
Norfolk, Virginia Superseded May 2013
Revised October 1, 2014
Appendix C Page 2 of 4
FDCC Adept File Naming
Overview
FDCC and other Coast Guard Civil Engineering Units use a file management and electronic file data base system, known as “Adept”. This system will provide many benefits to each unit and the U.S.
Coast Guard as a whole, with regard to management and access to facilities electronic documents.
This Guide is intended to provide a standard system for naming of the different types of electronic files related to facility engineering for Adept.
General
Electronic document names must be unique in order to keep Adept data properly identified. To achieve this, several things will be done. First each project is assigned unique Shore Facility Requirement List (SFRL) project number). And thirdly, unique codes and numbers will be included for each electronic file.
I AUTOCAD DRAWINGS:
A. “Sheet” File Names
The first group of numbers will be the USCG Project Number. The next characters shall be the Discipline Sheet Number (which shall consist of the Discipline Designator and Discipline Amplifier (Optional)) ,followed by Sheet Type Designator),Sheet Type sequence number, and As-Builts Designator.
Example:
4138942CU201.dwg
4138942 = Project Number assigned by USCG C = Discipline Designator (see Sheet Number below) U = Discipline Amplifier (Optional)
2 = Sheet Type Designator (see Sheet Type below) 0 = Facility Designator (see Sheet Number below)
1 = Sheet Type sequence number (Consecutive Number) asb = As-Builts .dwg = default AutoCAD file Extension
Discipline Sheet Numbering System
Each drawing SHEET shall be number using a Discipline Designator, Sheet Type Designator, Facility Designator and Sheet Type sequential numbers. XREF dwg files will be bound within the as-built sheet file.
Example: CU201
C = Discipline Designator U = Discipline Amplifier (Optional) 2 = Sheet Type Designator (See description below)
01 = Sheet Type sequential number (Consecutive beginning with 01, 02, 03 …..09, 10) the zero is just a place holder until there are two digits.
Appendix C Page 3 of 4
Discipline Designators:
G – General H - Hazardous Materials C - Civil L – Landscape S – Structural A – Architectural I – Interiors Q – Equipment F - Fire Protection P – Pluming M - Mechanical E - Electrical T – Telecommunications R - Resource LS-Life Safety FA – Fire Alarm
Discipline Amplifier (Optional):
U-Utility G-Grading D-Demolition E-Erosion S-(civil&struc.) W-?
A-Attenuator H-hazmat seawall? C-Crane T-Temporary F-Float
Sheet Type Designators:
0 – General (symbols, legends) 4 – Large Scale Plans 8 - User Defined 1 – Plans 5 – Details 9 – 3D View (isometrics, photos) 2 – Elevations 6 – Schedules & Diagrams 3 – Sections 7 – Control Sequences
B. XREF File Names
All X-referenced files which shall be attached/bound to the drawing.
II. SPECIFICATIONS AND RELATED TEXT DOCUMENTS
Construction specification, permits, O&M manual or other text document file shall begin with the USCG Project Number. The next characters are the letter “SP” for Specifications. The next characters shall be the specification section number.
4138942SP01158.doc
4138942 = Project Number assigned by USCG SP = Indicates Specifications
01158 = Specification Section number .doc, pdf = .doc or .pdf document file extension
Photo and Graphic Files
All raster image files (e.g., jpgs, tiffs, pdfs, bmps, gifs etc) shall be embedded into the CAD drawing.
Appendix C Page 4 of 4
Other Documents
The first group of numbers will be the USCG Project. The next three characters shall be consecutive beginning with 001 (one number for each file).
4138942xx001.xxx
4138942 = Project or OpFac Number assigned by USCG
001 = Consecutive number or other distinguishing factor
.xxx = applicable file extension
File details come from the government source that posted it. Updated .