PM-1415_Pkg C - PPHM Roof Replacement & Coating_Construction Drawings.pdf

PDF 3 MB Posted

Attached to
PM-1415 PPHM Roof Replacement & Coating State and local contract opportunity
Solicitation number
PM-1415
Issued by
Ochiltree County, Texas

About this file

These are construction drawings and specifications for a sealed-bid roof replacement and coating project by West Texas A&M University (WTAMU) through SSC Services for Education Facilities Services, focusing on Package C involving the Panhandle Plains Historical Museum (PPHM) in Canyon, Texas. The project encompasses roof replacement and coating work across multiple campus buildings, organized into nine base proposals within three work packages. Base Proposal 8 includes power washing and application of a new coating system over the existing modified bitumen roof at the PPHM (roof sections A, B, B1, B2, C, G, H, J, K, L, and M), with a two-year contractor's warranty, while Base Proposal 9 involves complete removal of the existing roof system down to the concrete deck, installation of new three-ply modified bitumen roofing with perlite insulation and cover board (roof sections D, E, and F), providing a twenty-year manufacturer's warranty and two-year contractor's warranty. The drawings include detailed roof plans, wind uplift pressure charts, and comprehensive technical specifications for all flashing, metal coping, scuppers, drains, equipment curbs, roof hatches, and penetrations. All work requires compliance with NRCA, SMACNA, and ANSI/SPRI standards, with master plumber certification required for gas line testing and certification. A pre-proposal meeting was held on February 12, 2026, at the WTAMU Physical Plant Conference Room, with proposals due by February 26, 2026, at 2:00 PM.

Lydick-Hooks was selected as the contractor offering best value with a base bid of $590,186.00 and a 110-day construction timeline, meeting all compliance requirements including submission of required warranty documentation. The top-ranked bidder by score, AG & Sons (with a score of 9.10 and bid of $533,473.25), was disqualified for failure to provide the required twenty-year warranty letter from the coating manufacturer. Evaluation criteria included total bid amount (51%), construction time (10%), technical proposal (24%), litigation and claims history (5%), safety and risk assessment (5%), and quality control (5%). Contractors were required to be approved applicators of the primary coating manufacturer with evidence of approved applicator status and a list of successfully completed similar projects submitted prior to bid. The coating manufacturer must have a minimum of twenty years in roof coating production and membership in good standing with the National Roofing Contractors' Association. A Historically Underutilized Business (HUB) subcontracting plan is required, with monthly HUB Progress Assessment Reports (PARs) mandated to accompany each pay application. Bids from responding contractors ranged from $533,473.25 to $3,317,650.00, with construction timelines ranging from 45 to 180 days.

View the file

Other files for this state and local contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP LOCATION MAP

NORTHNORTH

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

COVER SHEET

25-1183-49 01/20/2026

AA/JK

GS1.00

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

SHEET INDEX

Sheet Number Sheet Name

GS1.00 COVER SHEET

GS1.01 GENERAL ROOFING INFORMATION

GS2.00 WIND UPLIFT PRESSURE PLAN -

CLASSROOM CENTER & JACK B.

KELLY STUDENT CENTER

GS2.01A WIND UPLIFT PRESSURE PLAN -

PANHANDLE PLAINS HISTORICAL

MUSEUM

GS2.01B WIND UPLIFT PRESSURE PLAN -

PANHANDLE PLAINS HISTORICAL

MUSEUM

GS2.02 WIND UPLIFT PRESSURE PLAN -

CORNETTE LIBRARY

GS2.03 WIND UPLIFT PRESSURE PLAN -

GREENHOUSES

GS2.04 WIND UPLIFT PRESSURE PLAN -

CONNER HALL

R1.01 OVERALL ROOF PLAN -

CLASSROOM CENTER & JACK B.

KELLY STUDENT CENTER

R1.02 ENLARGED ROOF PLAN -

CLASSROOM CENTER

R1.03 ENLARGED ROOF PLAN - JACK B.

KELLY STUDENT CENTER

R1.04 OVERALL ROOF PLAN - CORNETTE

LIBRARY

R1.05 OVERALL ROOF PLAN - CONNER

HALL

R1.06 OVERALL ROOF PLAN -

GREENHOUSES

R1.07 OVERALL ROOF PLAN - PANHANDLE

PLAINS HISTORICAL MUSEUM

R2.01 ROOF DETAILS

R2.02 ROOF DETAILS

R2.03 ROOF DETAILS

R2.04 ROOF DETAILS

R2.05 ROOF DETAILS

WEST TEXAS A&M UNIVERSITY

ROOF REPLACEMENT PROJECT

MULTIPLE BUILDINGS

2501 4TH AVE,

CANYON, TEXAS 79016

M U

LT

IP

LE

B

U

IL

D

IN

G S

TH

A

VE

C

AN

YO

N , T

X

CLASSROOM CENTER & STUDENT CENTER

CONNER HALL

GREENHOUSES

CORNETTE LIBRARY

PANHANDLE PLAINS HISTORICAL MUSEUM

CONSTRUCTION

SEQUENCE

GLAZING

WINDOW FRAME

ADHERE SELF-ADH

FLASHING TO

SUBSTRATE, S.S.

BENT MTL & SIDE

OF WDW FRAME

TYP TERM BAR @ EDGE

OF SELF-ADH FLASHING

WALL SURFACE

WALL SURFACE

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

GENERAL ROOFING

INFORMATION

25-1183-49 10/07/2025

AA/JK

GS1.01

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

S.

T.

U.

V.

W.

X.

Y.

Z.

AA.

AB.

AC.

AD.

AE.

GENERAL ROOF NOTES:

PROVIDE ALL REQUIRED UTILITY / STRUCTURAL COMPONENTS AND/OR CONNECTIONS FOR

THE FUNCTIONAL USE OF ALL CONTRACTOR SUPPLIED EQUIPMENT OR APPLIANCES,

REGARDLESS OF ANY OMISSIONS OR INCONSISTENCIES ENCOUNTERED IN THE

CONSTRUCTION DOCUMENTS.

THE WORD 'PROVIDE' SHALL MEAN 'FURNISH AND INSTALL' COMPLETE AND READY TO USE.

IF DISCREPANCIES APPEAR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE

HIGHER QUALITY, QUANTITY, AND PRICE SHALL SUPERSEDE.

THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BECOME FAMILIAR WITH THE

PROJECT AND THE ON-SITE / OFF-SITE CONDITIONS PRIOR TO BIDDING OR COMMENCING

WORK.

PROVIDE METAL END CLOSURE ON EXPANSION JOINTS WHERE THEY OCCUR AT THE EDGE

OF THE ROOF.

ROOF SLOPES SHOWN ON DRAWINGS ARE GENERAL AND CONCEPTUAL ONLY. TAPER

INSULATION IS SHOWN CONCEPTUALLY AND FOR INTENT ONLY; NOT TO SCALE AND

SHOWN AS GRAPHIC REPRESENTATION ONLY TO SHOW SLOPE. INTENT IS TO PROVIDE

POSITIVE DRAINAGE TO ALL ROOF DRAINS, SCUPPERS, AND GUTTERS. VERIFY INSULATION

AND TAPER IN SHOP DRAWINGS AS REQUIRED TO MAINTAIN SLOPE PRIOR TO

INSTALLATION. REFER TO STRUCTURAL (IF APPLIES) FOR EXACT TOS/BOD ELEVATIONS.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

PROVIDE TAPERED INSULATION CRICKETS (1/2"/FT. MIN. SLOPE) AT HIGH SIDE OF ALL

MECHANICAL UNITS, SMOKE VENTS, ROOF HATCHES, AND OTHER MISC. ROOF

PENETRATIONS, TO SHED WATER AROUND AND TO ENSURE POSITIVE ROOF DRAINAGE.

PROVIDE ADDITIONAL MANUFACTURER'S WALK PADS AS PROTECTION AT "SERVICE SIDE"

OF ALL MECHANICAL EQUIPMENT - FIELD VERIFY LOCATIONS. AS WELL AS PROTECTION AT

"ACCESS SIDE" OF ALL ROOF HATCHES AND ROOF ACCESS LADDERS - FIELD VERIFY

LOCATIONS, AND AT DOWNSPOUT LOCATIONS.

ALL WOOD BLOCKING AT ROOF EDGES ARE TO BE FABRICATED FROM CONT. 2X6 FR-WD

BOARDS. PROVIDE LARGER 2X FR-WD AS REQUIRED PER DIMENSIONED DETAILS OR AS

FIELD CONDITIONS DICTATE. ALL COPING TO BE SLOPED TOWARD THE INTERIOR.

ALL EXPOSED FLASHING, COPING (IF APPLICABLE), AND THEIR ACCESSORIES SHALL BE AS

SPECIFIED.

HEIGHT OF ALL NAILERS SHALL BE FLUSH WITH NEW INSULATION THICKNESS.

ALL THROUGH WALL FLASHING SYSTEMS TO ACCOMMODATE 8" MINIMUM FLASHING

HEIGHT FROM FINISHED ROOF SURFACE. PROVIDE END DAMS AS CONDITIONS ALLOW. ALL

FLASHING TO HAVE 4" LAP MINIMUM AND OR STEP.

ALL PITCH PANS SHALL BE DOUBLE SOLDERED STAINLESS STEEL AND RECEIVE EITHER

MECHANICALLY ATTACHED GOOSENECKS OR METAL BONNETS. METAL BONNETS SHALL

BE SECURED WITH CLAMPING RING AND SEALANT. SPECIAL CARE GIVEN TO WASH ALL

METAL PRIOR TO INSTALLATION.

ALL INFIELD EXPANSION JOINTS SHALL HAVE LOW SLOPED STANDING SEAM JOINTS AND

SHALL BE CHAMFERED AT TERMINATION AT ROOF EDGE TO MEET PROFILE OF PERIMETER.

ANY CRACKS OR VOIDS IN RISE WALLS ABOVE COUNTER FLASHING SHALL BE REPAIRED

WITH COMPATIBLE SEALANT.

ALL VERTICAL MEMBRANE FLASHING SHALL BE MECHANICALLY FASTENED AND INSTALLED

WITH NEW METAL COUNTER FLASHING UTILIZING A CONTINUOUS CLEAT. SLIDE METAL

COVER PLATE DOWN OVER VERTICAL CLEAT AND SEAL.

PROVIDE NEW CONCRETE SPLASH BLOCKS ON ROOF ELEVATION ON TOP OF A WALK PAD

WHERE DOWNSPOUTS OCCUR.

ALL PIPES AND CONDUIT SHALL RECEIVE PIPE SUPPORTS AND RELATED SHIMS AND SHALL

BE PLACED ON AN ADDITIONAL ADHERED ROOF MEMBRANE UNDER SPECIFIED WALK PAD

PRIOR TO SURFACE APPLICATION. SUPPORTS TO OCCUR AT 10'-0" O.C. AND WITHIN 2'-0" OF

ALL SLOPES, TEES AND CORNERS. ALL PIPES TO BE PAINTED PER BUILDING CODE

REQUIREMENTS.

ALL METAL FLASHING SHALL EXTEND BEYOND ROOF EDGE MIN. 8" WHERE FLASHING

ABUTS VERTICAL WALL SURFACE AS DETAILED. ALL FLASHING SHALL BE INSTALLED IN

SHINGLE FASHION.

AT ALL LOCATIONS WHERE CONVERGENCE OF MULTIPLE PLANES OF ROOFING TO WALL

OCCUR, FIELD FABRICATE THERMOPLASTIC BOOT TO BE INSTALLED OVER NEW ROOFING,

COMPLETELY OVERLAYING THE TRANSITIONS OF ALL ROOF TO WALL, ELEVATIONS, INSIDE

AND OUTSIDE 90 DEGREE CORNERS, ETC. PRIOR TO METAL INSTALLATION.

ALL EQUIPMENT CURBS TO BE RAISED AS NECESSARY TO MAINTAIN 10" MINIMUM HEIGHT

ABOVE FINISHED ROOF SURFACE.

MECHANICAL, ELECTRICAL, AND PLUMBING ROOF EQUIPMENT SHOWN ON THIS PLAN IS

FOR GENERAL INFORMATION ONLY.

FLASHING AND STRIPPING MATERIALS, BASE PLY SHEETS, MEMBRANES, INSULATION, AND

ACCESSORIES SHOULD BE AS RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER

FOR INTENDED USE AND COMPATIBILITY WITH THE MEMBRANE ROOFING SYSTEM.

WHERE WOOD BLOCKING EXCEEDS 6" IN VERTICAL THICKNESS AT TAPERED INSULATION,

PROVIDE STEM WALL CONSTRUCTED OF 6" GALVANIZED COLD FORMED METAL FRAMING

AT 16" O.C. WITH CONT. TRACK AT TOP AND BOTTOM AND WITH 3/4" FR-EXT GRADE

PLYWOOD AT EACH SIDE, TOP TO SLOPE WITH TAPERED INSULATION.

PROVIDE STEP FLASHING AND COVER PLATE AT SLOPED ROOF HIGH/LOW CONDITIONS.

GUTTERS SHALL BE PREFINISHED GALVANIZED STEEL, SIZE PER DRAWINGS, UNO.

PROVIDE PREFINISHED 1/4"x1 1/2" GALVANIZED STEEL BENT PLATE BRACKETS AND

PREFINISHED 1" GALVANIZED STEEL SPACERS AT 36" O.C. MAX, STAGGER WITH EACH

OTHER AT 18" O.C.

PROVIDE PREFINISHED GUTTER EXPANSION JOINTS 50'-0" O.C. MAX.

DOWNSPOUTS SHALL BE 5"x6" PREFINISHED GALVANIZED STEEL UNO WHERE LOCATED ON

ROOF PLAN. PROVIDE PREFINISHED 2" GALVANIZED STEEL HANGERS AT 36" O.C.

COORDINATE LOCATION WITH ARCHITECT PRIOR TO INSTALLATION.

PROVIDE SPLASH BLOCKS AT ALL ROOF LEADER NOZZLES THAT SPILL ONTO GROUND.

VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO

INSTALLATION OF SCUPPERS.

LOCATE SCUPPERS AS INDICATED ON ELEVATIONS, EITHER CENTERED OVER

WINDOWS/OPENINGS, OR CENTERED BETWEEN WINDOWS/OPENINGS, UNO. ADJUST

PLACEMENT TO MEET MASONRY COURSING MODULES.

RTU MEME/G

P

EJ

OD

DS

OS

RD

RW RW/EJ

ODRD

SCSC

PITCH PAN

DS/SB

SPLASHBLOCK

DOWNSPOUT/

DS/CH

COLLECTOR HEAD

DOWNSPOUT/

P/EJ

RME

CW E

EDP

HS

VA

RPH

CD

CH

ETEL / FO

G

P/EJ

EXPANSION JOINT

AT PARAPET

METAL EDGE RISE WALL RISE WALL

W/EXPANSION

JOINT

RAISED METAL

EDGEPRIMARY AND

OVERFLOW ROOF

DRAIN

EXPANSION

JOINT

METAL EDGE

W/GUTTER

THROUGH

WALL

SCUPPER

OVERFLOW

SCUPPER PARAPET

SLOPE

DIRECTIONEXPANSION JOINT

AT PARAPET

ROOF LADDER

EDGE SCUPPER

CURB

MOUNTED

EQUIPMENT

MISC. EQUIP.

ON EQUIP.

CURBS

PRIMARY

ROOF

DRAIN

OVERFLOW

ROOF DRAIN

SOIL /

PLUMBING

VENT

FLANGE

MOUNTED

EQUIPMENT

HOT

STACK

CURB

MOUNTED

VENT

ANTENNA ELECTRICAL

DISTRIBUTION

PANEL

GUY

WIRE

ROOF

PENETRATION

HOUSING

SST SPLASH

PAN /

SUPPORT

PAD

ROOF TOP

UNIT

MISC.

EQUIPMENT

ROOF

HATCH

SKYLIGHT

PROCESS

VENT

STACK

FLANGE

MOUNTED

VENT

SATELLITE

DISH

CHILLER

LINE

GAS LINE

VENT

STACK

SECURITY

CAMERA

WATER

HYDRANT

ELECTRIC

DISCONNECT

PEDESTAL

CONDENSATE

LINE

ELECTRIC

LINE

TELE /

FIBER

OPTICS

ANCHOR

STANCHION

SL DOWNSPOUT

ROOF LEGEND

NOT IN CONTRACT

ROOF LEGEND

SHINGLE

ROOF SYSTEM

ROOF LEGEND

LOW SLOPE

ROOF SYSTEM

NRD

NEW

ROOF

DRAIN

WALK PAD AT

SERVICE SIDE

OF UNIT

ROOF TOP

UNIT

1/2" TAPERED

CRICKET ON HIGH

SIDE OF RTU

RTU

ROLLER AND SUPPORT LEG SIZE IS DEPENDENT ON PIPE OR

CONDUIT SIZE. MANUFACTURER TO PROVIDE PROPER SIZING

BASED ON FIELD CONDITIONS.

THREADED RODS,

NUTS, AND WASHERS

HIGH DENSITY

POLYPROPYLENE

PLASTIC W/ UV

INHIBITORS, TYP.

5/8" NEOPRENE PAD

RD OD

OS

RD

RECESSED PRIMARY AND

OVERFLOW DRAIN SUMP

1/2" TAPERED

CRICKET

RECESSED PRIMARY DRAIN

SUMP AND OVERFLOW SCUPPER

RD OD

RECESSED PRIMARY AND

OVERFLOW DRAIN SUMP

1/2" TAPERED

CRICKET

NOTES:

1. SUPPORT LEG SIZE IS

DEPENDENT ON PIPE OR

CONDUIT SIZE.

MANUFACTURER TO PROVIDE

PROPER SIZING BASED ON

FIELD CONDITIONS.

2. SET ON SACRIFICIAL SHEET.

16" NOMINAL

MASONRY BLOCKS

HOT DIP GALVANIZED STEEL MAST

SACRIFICIAL

MEMBRANEEXTEND MEMBRANE UP AND

OVER TOP OF PARAPET

WALL ATTACH ON FRONT

EDGE OF WALL SYSTEM

PREFINISHED METAL COPING

COLOR AS SELECTED BY OWNER

EXTEND METAL UP UNDER FLASHING

ABOVE AND SEAL WATERTIGHT

HIDDEN VERTICAL CLIP ATTACHED TO

BOTH SIDES OF WALL SYSTEM. SLIDE

PREFINISHED METAL DOWN OVER CLIP

AND PROVIDE BEAD OF SEALANT CONT,

VERTICAL BETWEEN EDGE AND

SURFACE ADJACENT PLANE.

EXTEND METAL FLASHING UP UNDER

COPING AS SHOWN

PREFINISHED METAL COPING COLOR

AS SELECTED BY OWNER

INTERIOR

CLOSURE

SCUPPER

LINER

EXTERIOR

CLOSURE

3" MIN.

FLANGE

SEAL EXTERIOR

CLOSURE TO

SCUPPER LINER WITH

APPROVED SEALANT

EXTERIOR CLOSURE

FLANGE WITH FORMED

EDGES ON 3 SIDES TO

RECEIVE APPROVED

SEALANT

3" MIN.

FLANGE

4" MIN.

FLANGE

SHEET METAL LINER

WELDED OR FABRICATED

FROM MEMBRANE

COATED METAL

5/8" NEOPRENE PAD

PIPE STAND SIZED

NOTES:

1. SUPPORT LEG SIZE IS DEPENDANT

ON PIPE OR CONDUIT SIZE.

MANUFACTURER TO PROVIDE

PROPER SIZING BASED ON FIELD

CONDITIONS.

2. SET ON SACRIFICIAL SHEET.

PIPE OR CONDUIT

ILLUSTRATION

ONLY

STRUT CLAMP

5/8" NEOPRENE PAD

" M

AX

4.

" M

IN

END

VIEW

WALK PADS

SAFETY

RAILING

ROOF HATCH

1/2" TAPERED

CRICKET ON HIGH

SIDE OF ROOF

HATCH

WALK PAD

ROOF LADDERS

WALK PADS

PARAPET

STAINLESS

STEEL FALL

PROTECTION

SCREEN

FALL

PROTECTION

SCREEN

OSHA APPROVED

LENS ARE

ACCEPTABLE

FIBERGLASS REINFORCED

POLYMER (FRP),

YELLOW, UV RESISTANT &

FIRE RETARDANT (∅1.91)

ALUMINUM POST HINGE

STAINLESS STEEL

TORSION ROD

SELF CLOSING (FRP)

GATE (∅1.91)ALUMINUM GATE HINGE

STEEL CORNER

BRACKETS (HOT

DIP GALVANIZED)

ALUMINUM

POST

SUPPORTS

42" ABOVE THE

ROOF SURFACE

OR DECK

SKYLIGHT WITH

FALL PROTECTION11

ROOF TO ROOF LADDER

WITH WALK PADS2ROOF TOP UNIT -

WALK PAD LAYOUT3ROOF HATCH

WALK PAD LAYOUT4ROOF HATCH

SAFETY RAILING5

ROLLER PIPE SUPPORT8LARGE PIPE -

PIPE STAND9 TAPERED CRICKETTAPERED SADDLES

ANTENNA SUPPORTCOPING END CAP

SCUPPER SHEET METAL10

14 13

7 6

NOT TO SCALE

ROOF PLAQUE1

NOT TO SCALENOT TO SCALENOT TO SCALENOT TO SCALE

NOT TO SCALE

NOT TO SCALE NOT TO SCALENOT TO SCALE

NOT TO SCALENOT TO SCALE

NOT TO SCALE

NOT TO SCALE

TYP SELF-ADH FLASHING

(AT WALL OPENINGS)12

NOT TO SCALE

DO NOT MAKE REPAIRS OR ALTERATIONS

TO THIS ROOF WITHOUT APPROVAL FROM THE

DIRECTOR OF OPERARIONS AND MAINTENANACE OFFICE

PROJECT NAME

PROJECT ADDRESS

THIS ROOF IS GUARANTEED FROM XX/XX/XX UNTIL XX/XX/XX

SCHOOL DISTRICT NAME,

DAY PHONE NUMBER

EMERGENCY PHONE NUMBER

ENVELOPE CONSULTANT NAME, PHONE NUMBER

ROOFING MANUFATURER NAME, PHONE NUMBER

GENERAL CONTRACTOR NME, PHONE NUMBER

ROOFING CONTRACTOR NAME, PHONE NUMBER

M U

LT

IP

LE

B

U

IL

D

IN

G S

C

AN

YO

N

, T X

B J

H

G

C

E

D

A

K

L

M

F

REFER TO SHEET GS2.01B FOR WIND UPLIFT

PRESSURE CHART AND WIND UPLIFT KEY

1'

1' 1'

1' 1'

1 1

2 2

3 3

3 3

3 3 3

3 3

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

WIND UPLIFT

PRESSURE PLAN -

PANHANDLE PLAINS

HISTORICAL

MUSEUM

25-1183-49 10/07/2025

AA/JK

GS2.01A

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

PA

N

H

AN

D

LE

P

LA

IN

S

H

IS

TO

R

IC

AL

M U

SE

U

M

TH

A

VE

C

AN

YO

N

, T X

1/16" = 1'-0"

1 WIND UPLIFT PLAN - OVERALL - MUSEAM

0.

6h

0.

6h

0.6h 0.6h

0.6h

0.

6h

0.2h

0.

2h

ZONE 1'

ZONE 1

ZONE 2

ZONE 3 ZONE 3

ZONE 3 ZONE 3

1/32" = 1'-0"

1 UPLIFT KEY PLAN - LOW SLOPE

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

WIND UPLIFT

PRESSURE PLAN -

PANHANDLE PLAINS

HISTORICAL

MUSEUM

25-1183-49 10/07/2025

AA/JK

GS2.01B

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

PA

N

H

AN

D

LE

P

LA

IN

S

H

IS

TO

R

IC

AL

M U

SE

U

M

TH

A

VE

C

AN

YO

N

, T X

A

B

C

E D

F

G

J

H

K

L

M

SL

O

PE

SL

O

PE

RD RD

RM

E

RM

E

RME

B1 B2

RW

RME

R M

E

R M

E

HATCHRW

R

WR

W

RW

R

WR

W

M E

M E

ME

LADDER

RDRD

RD RD

RME

EJ

RME

R M

E

RME

EJ

P

RW

PR

W

R W

P

R W

/E J

P

SC/CH

SC/CH

SC

/C

H /S

B

SC/CH

RD

SLSL SL SL

SL

SL

SL

R

TU

RW

P

P

PP P

PP

LADDER

LADDER

P

P

P P

P

R W

SL SL

SL

O

PE

SL

O

PE

SL

O

PE

P

P

P

P

P

PP

P

SL

O

PE

LADDER

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

P

P

P

P

P

P

P

P

P

P

P

SL

O

PE

SL

O

PE

SL

O

PE

RW/EJ

R W

/E J

RW P

P

P

LA

D

D

ER

P

RD

R D

R D

R D

R D

R D

R D

R D

R D

R D

R D

RD RD RDRD RD

RD

RDRD

RD RD

RD

RTU RTU

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

HATCH

R W

/E J

P

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

TRANSITION

R

TU

R

TU

SC

/C

H

SC

/C

H

SC

/C H

/S B

SC

/C

H /S

B

SL

O

PE

P

P

P

P

P/EJ/RW

P/

EJ

/R W

P P

R W

RME

R W

/E J

RW

R W

RW

LADDER

RW/EJ

RW

R W

R W

/E J

P

P

P

P

SL

O

PE

R W

/E J

RD RD RD

RD RD

RD RD RD

SL

O

PE

SL

O

PE

SL

O

PE

SL

O

PE

SC

/C

H

SC/SB

5 5 5 5

5 5 5 5

5 5

5 5

5 5 5

5 5

7 8 TYP

8 7

TYP

8 7

TYP

TYP

7 8

TYP

TYP

TYP

TYP

7 8

TYP

8 7TYP

TYP

TYP

TYP

TYP

TYP

12 12 12 12

RTU

NRD

NRD NRD

NRD

16NRD

NRDNRD

NRD

ME

SLOPE

SLOPE

SLOPE

SLOPE

16 16 16

7 8

TYP

15 15

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

OVERALL ROOF

PLAN - PANHANDLE

PLAINS HISTORICAL

MUSEUM

25-1183-49 10/07/2025

AA/JK

R1.07

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

SPECIFIC ROOF NOTES:

RAISE ROOF HATCH AS REQUIRED TO MAINTAIN 8" HEIGHT ABOVE ROOF

SURFACE.

ADD WOODEN NAILERS TO TOP OF PARAPET AS REQUIRED TO PROVIDE A

NAILABLE SURFACE FOR THE NEW METAL COPING AND WIND CLEAT.

ALL INTERIOR PARAPET WALLS TO HAVE NEW 3/4 “ INCH PLYWOOD INSTALLED

AND PROPERLY FASTENED TO THE VERTICAL SURFACE IN ORDER TO

RECEIVE THE NEW FLASHING MEMBRANE AS DETAILED.

24 GAUGE PREFINISHED METAL COPING SHALL BE INSTALLED UTILIZING A

LOW-PROFILE STANDING SEAM AS DETAILED

INSTALL ONE-HALF INCH PER FOOT CRICKETS TO PROVIDE POSITIVE SLOPE

TO THE EXISTING DRAINS.

PROVIDE AN ADDITIONAL PLY OF THE FINISH PLY MEMBRANE UNDER ALL NEW

PIPE SUPPORT STANDS. ALL GAS LINES TO BE PAINTED YELLOW.

ALL NEW AND EXISTING DRAIN ACCESSORIES TO BE PAINTED RED.

VERIFY IN WRITING TO PROJECT MANAGER THAT ALL DRAINS AND LINES ARE

FREE FLOWING AND WATERTIGHT PRIOR TO SUBSTANTIAL COMPLETION.

INSTALL NEW COPPER CONDUCTOR HEADS AND DOWNSPOUTS.

INSTALL NEW TAPERED INSULATION SYSTEM IN ORDER TO PROVIDE POSITIVE

SLOPE TO THE DRAINAGE.

PROVIDE DECK INFILL AT EXISTING ABANDONED CURB. PROVIDE ADDITIONAL

FRAMING AS REQUIRED TO SUPPORT NEW METAL DECK. DECK TYPE TO

MATCH EXISTING STYLE, SIZE AND PROFILE.

REMOVE AND REPLACE ANY BROKEN SKYLIGHT PANELS.

ENSURE ALL BASE FLASHING AND THRU WALL FLASHING MEET THE MINIMUM

8” INCH REQUIREMENTS.

RAISE EQUIPMENT CURBS AS NEEDED TO MAINTAIN 12" MINIMUM FLASHING

HEIGHT.

REMOVE AND REPLACE ALL EXISTING ROOF DRAIN BOWLS AND DOMES.

PROVIDE 1/8" PER FOOT CRICKET.

CUT BOTTOM OF LADDER AS NECESSARY.

INSTALL NEW CAST IRON ROOF DRAINS AND PIPING AS NOTED ON THE ROOF

PLAN.

CAP CHIMNEY WITH 2X NAILERS AND 3/4" PLYWOOD COVERED, WITH HIGH

TEMP PEEL AND STICK MEMBRANE AND 24 GAUGE PREFINISHED CAP.

ALL WALL JOINT ABOVE FINISHED ROOF LINE TO BE GRINDED OUT. INSTALL

NEW BACKER RD AND RE-SEAL.

PROVIDE PARAPET TO RISEWALL EXPANSION JOINT AS DETAILED.

PROVIDE ROOF TO ROOF EXPANSION JOINT AS DETAILED.

PRVIDE ROOF TO RISEWALL EXPANSION JOINT AS DETAILED.

TRUE

NORTH

NOT TO SCALE1 OVERALL ROOF PLAN - PANHANDLE PLAINS HISTORICAL MUSEUM

PA

N

H

AN

D

LE

P

LA

IN

S

H

IS

TO

R

IC

AL

M U

SE

U

M

TH

A

VE

C

AN

YO

N

, T X

SCOPE OF WORK PACKAGE III:

BASE PROPOSAL 8 – WTAMU PANHANDLE PLAINS HISTORICAL MUSEUM – ROOF

COATING – ROOF SECTIONS (A, B, B1, B2, C, G, H, J, K, L & M)

WORK SHALL INCLUDE POWER WASHING THE EXISTING MODIFIED BITUMEN

ROOF SYSTEM .

MAKE ALL NECESSARY REPAIRS TO ANY AND ALL DEFICIENCIES BEFORE

INSTALLING THE BASE LAYER OF COATING

INSTALL NEW COATING AS PER THE MANUFACTURER ’S WRITTEN INSTRUCTIONS

AND SPECIFIED RATES.

PROVIDE A TWO (2) YEAR CONTRACTOR'S WARRANTY.

NEW METAL COPING CAP AND ACCESSORIES SHALL BE PREFINISHED,

SELECTED BY THE OWNER FROM A FULL RANGE OF COLORS INCLUDING

PREMIUM AND METALLICS.

WORK SHALL ALSO INCLUDE ALL HVAC AND ELECTRICAL, PIPING DIS-CONNECT

AND RE-CONNECTION.

INSTALLATION SHALL BE AS PER NRCA, SMACNA, ANSI/SPRI, SPECIFICATIONS,

DETAILS AND MANUFACTURER'S GUIDELINES. ALL GAS LINES TO BE TESTED AND

CERTIFIED BY A LICENSED PLUMBER.

BASE PROPOSAL 9 – WTAMU PANHANDLE PLAINS HISTORICAL MUSEUM – MODIFIED

BITUMEN – ROOF SECTIONS (D, E, & F)

WORK SHALL INCLUDE REMOVAL OF THE EXISTING ROOF SYSTEM DOWN TO

THE LIGHTWEIGHT CONCRETE DECK.

MECHANICALLY FASTEN A VENTING BASE SHEET TO THE DECK AS PER ASCE 7

CRITERIA.

PROVIDE A THREE-QUARTER INCH (3/4”) PERLITE INSULATION BOARD SET IN

SPECIFIED ADHESIVE.

INSTALL ALL ASSOCIATED CRICKETS SET IN SPECIFIED ADHESIVE AS NOTED ON

ROOF PLANS.

PROVIDE A ONE-HALF INCH (1/2”) COVER BOARD SET IN SPECIFIED ADHESIVE.

PROVIDE A NEW TWO-PLY MODIFIED BITUMEN ROOF SYSTEM SET IN COLD

APPLIED ADHESIVE. ALL END AND SIDE LAPS TO BE HOT AIR WELDED.

PROVIDE A TWENTY (20) YEAR NDL MANUFACTURER ’S WARRANTY AND A TWO

(2) YEAR CONTRACTOR’S WARRANTY.

NEW METAL SHALL BE PREFINISHED, SELECTED BY THE OWNER FROM A FULL

RANGE OF COLORS.

WORK SHALL ALSO INCLUDE ALL HVAC AND ELECTRICAL, PIPING DISCONNECT

AND RECONNECTION.

INSTALLATION SHALL BE AS PER NRCA, SMACNA, ANSI/SPRI, SPECIFICATIONS,

DETAILS AND MANUFACTURER’S GUIDELINES.

ALL GAS LINES TO BE TESTED AND CERTIFIED BY A MASTER PLUMBER.

BE

LO

W B

LO

C

KI

N

G

10' MAXIMUM

LENGTH OF EACH PIECE

OF PARAPET CAP

1" M

IN

MIN.3/4" LAP

THERMAL INSULATION

COVERBOARD

PLY SHEET

EXTEND PLY SHEET

FLASHING AND FIELD SHEET

ABOVE HEAD OF CANT

HIGH-DOME, CAPPED,

GASKETED FASTENERS

(APPROX. 12" O.C.)

PREFINISHED METAL

PARAPET CAP

CANT STRIP

3/4" EXT. GRADE PLYWOOD

TOP AND BOTTOM OF

NAILERS

CONT. CLEAT

CONT. 2X6 WOOD

SHIM FORM TOP FOR

SLOPE

CONT. 1X4 WOOD

SHIM FORM TOP FOR

SLOPE

3/4" EXTERIOR GRADE

F.R. PLYWOOD

1- 1/

2" M

IN

8"

STANDING SEAM METAL CAP

WITH CONTINUOUS CLEAT ON

THE OUTSIDE CRIMP ENDS

OVER AT 45 DEGREE ANGLE

5' -0

" M

AX

IM

U

M

FLASHING - SET VERTICALLY

PLY SHEET FLASHING

HIGH TEMPERATURE

UNDERLAYMENT UNDER

COPING CAP

FASTENERS

EXTEND PLY SHEET UP AND

OVER PARAPET

ROOF DECK

BASE SHEET IF REQUIRED

PRIME WALL WHEN APPLICABLE

FIELD SHEETPLY SHEET

BE

LO

W B

LO

C

KI

N

G 1-

1/ 2"

M

IN

10' MAXIMUM

LENGTH EACH PIECE

OF PARAPET CAP

1" M

IN

3/4" LAP

FLASHING

FIELD SHEET

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

EXTEND PLY SHEET DOWN OVER

WOOD BLOCKING

PREFINISHED METAL PARAPET CAP

STANDING SEAM METAL CAP WITH

CONTINUOUS CLEAT ON THE OUTSIDE

CRIMP JOINT ENDS AT 45 DEGREES

3/4" EXT. GRADE PLYWOOD TOP

AND BOTTOM OF NAILERS

CANT STRIP

3/4" EXTERIOR F.R.

GRADE PLYWOOD

CONT. 2X6 WOOD SHIM

FORM TOP FOR SLOPE

CONT. 1X4 WOOD SHIM

FORM TOP FOR SLOPE

CONTINUOUS CLIP

4"

4"

PLY SHEET FLASHING

EXTEND PLY SHEET

FLASHING AND FIELD SHEET

ABOVE HEAD OF CANT

EXTEND PLY SHEET UP AND

OVER PARAPET

PRIME WALL WHEN APPLICABLE

BASE SHEET AS REQUIRED

HIGH TEMP ICE AND WATER

SHIELD MEMBRANE OVER

TOP OF PARAPET

ROOF DECK

THERMAL

INSULATION

COVERBOARD

10' MAXIMUM

LENGTH OF EACH PIECE

OF PERIMETER FLASHING

BE

LO

W B

LO

C

KI

N

G 1-

1/ 2"

M

IN

APPROX. 4"

6" M

IN.

GAP

APPROX. 1/2"

1/

2"

FIELD SHEET

EXTEND FLASHING APPROX. 4"

BEYOND TOE OF CANT

EXTEND PLY SHEET FLASHING

BELOW BLOCKING

SHEET METAL FASCIA CAP

HIGH-DOMED, CAPPED

GASKETED FASTENERS

(APPROX. 18" O.C., DEPENDING

UPON WIND ZONE AND LOCAL

CONDITIONS)

SHEET METAL JOINT COVER

PLATE SET IN TWO BEADS OF

SEALANT

FLASHING

COVERBOARD

THERMAL INSULATION

BASE SHEET IF REQUIRED

ROOF DECKNEW / EXISTING WOOD

NAILERS

WOOD CANT

FASTEN TO

BLOCKING

FASTEN BASE

FLASHING ON FACE

OF STRUCTURAL

CANT TO MINIMIZE

PENETRATION OF

FLASHING -

APPROX. 8" O.C.

CONTINUOUS CLEAT

ATTACHED 8" O.C.

PLY SHEET

PLY SHEET FLASHING

BE

LO

W B

LO

C

KI

N

G 1-

1/ 2"

M

IN

3" MIN.

3" MIN.

4" WIDE

FLANGE APPROX.10' MAXIMUM

OF PERIMETER FLASHING

LENGTH OF EACH PIECE

APPROX. 1/2"

GAP

FLASHING

PLY SHEET FLASHING

FIELD SHEET

PREFINISHED METAL JOINT

COVER PLATE 6" WIDE MIN. -

SET IN TWO BEAD OF SEALANT

PREFINISHED METAL

"GRAVEL STOP" SET IN

ROOF CEMENT; PRIME

FLANGE BEFORE

STRIPPING

PLY SHEET

COVERBOARD

THERMAL INSUL.

ROOF DECK

EXISTING /

NEW WOOD

NAILERS

EXTEND BASE FLASHING

MEMBRANE BELOW

BLOCKING

CONTINUOUS CLEAT

FASTENERS AT

APPROX. 3"

O.C.

STAGGERED

BASE SHEET IF REQUIRED

THERMAL INSULATION

SEALANT AT WALLS JOINTS MUST BE

COMPATIBLE WITH COUNTERFLASHING

SEALANT

INSTALL POLYURETHANE SEALANT

AND

TOOL TO FACILITATE WATER RUN-OFF

EXPANDING SHANK FASTENERS

(APPROX. 12" O.C., DEPENDING UPON

WIND ZONE AND LOCAL CONDITIONS)

3" LAP AT JOINTS

SHEET METAL COUNTERFLASHING

COMPRESSIBLE ELASTOMERIC TAPE

TO SPAN IRREGULARITIES

FASTENER FASTENED APPROX. 8" O.C.

PRIME WALL WHERE APPLICABLE

EXTEND FIELD PLIES ABOVE

HEAD OF CANT

FLASHING

FIELD SHEET

PLY SHEET FLASHING

PLY SHEET

COVERBOARD

ROOF DECK

SEAL TOP OF FLASHING WITH A

3-COURSE OF VERTICAL GRADE

PROOF CEMENT AND

REINFORCEMENT FABRIC

BASE SHEET IF REQUIRED

CANT STRIP

SHEET METAL COUNTERFLASHING

BE

LO

W B

LO

C

KI

N

G 1"

M

IN

10' MAXIMUM

LENGTH EACH PIECE

OF PARAPET CAP

1" M

IN

MIN.

3/4" LAP

FLASHING

ROOF DECK

BASE SHEET AS

REQUIRED

THERMAL INSULATION

COVERBOARD

PLY SHEET

EXTEND FIELD PLIES

ABOVE HEAD OF CANT

3/4" EXT. GRADE

PLYWOOD TOP AND

BOTTOM OF NAILERS

DOUBLE SIDED TAPE

BETWEEN LAP &

COPING LEG.

2 RIVETS PER VERT.

OVERLAP

HIGH-DOMED, CAPPED,

GASKETED FASTENERS

(APPROX. 18" / 12" O.C.)

EXTEND BASE FLASHING

DOWN OVER WOOD

BLOCKING

PREFINISHED METAL

PARAPET CAP

STANDING SEAM METAL

CAP WITH CONTINUOUS

CLEAT ON THE OUTSIDE.

CANT STRIP

3/4" EXTERIOR F.R.

GRADE PLYWOOD

CONT. 2X6 WOOD SHIM

FORM TOP FOR SLOPE

CONT. 1X4 WOOD SHIM

FORM TOP FOR SLOPE

CONTINUOUS CLIP

PLY SHEET FLASHING

FIELD SHEET

8" N

O M

IN

AL

FL

AS

H

IN

G H

EI

G

H T

FIELD SHEET

FLASHING

COVERBOARD

THERMAL INSUL.

EXTEND FIELD PLY ABOVE

HEAD OF CANT STRIP

FASTENERS

HIGH-DOMED, CAPPED,

GASKETED FASTENERS

(APPROX. 12" O.C.)

FLEXIBLE WATERPROOF

MEMBRANE CLOSURE

BEVEL TOP OF BOTH

WOOD CURBS TO DRAIN

TO ONE SIDE

SHEET METAL EXPANSION

JOINT COVER

WOOD CANT

WOOD NAILERS

EXTEND BASE FLASHING

UP AND OVER WOOD

BLOCKING

COMPRESSIBLE INSUL.

EQUAL

TO EJ

2"

FLEXIBLE VAPOR RETARDER

TO SERVE AS INSUL.

RETAINER (ATTACHED TO

TOP OF CURB)

PLY SHEET

PLY SHEET FLASHING

STANDING SEAM METAL CAP

WITH CONTINUOUS CLEAT ON

THE OUTSIDE CRIMP ENDS

OVER AT A 45 DEGREE ANGLE

ROOF DECK

BASE SHEET AS REQUIRED

BE

LO

W B

LO

C

KI

N

G

10' MAXIMUM

LENGTH OF EACH PIECE

OF PARAPET CAP

FIELD SHEET

FLASHING

1" M

IN

MIN.3/4" LAP

FLASHING MEMBRANE HEAT

WELD TO CLAD METAL

RECEIVER

ROOF DECK

THERMAL INSULATION

COVERBOARD

PLY SHEET

EXTEND FIELD PLY ABOVE

HEAD OF CANT

PRIME WALL WHEN

APPLICABLE

EXTEND BASE FLASHING UP

& OVER WOOD BLOCKING

HIGH-DOME, CAPPED,

GASKETED FASTENERS

(APPROX. 12" O.C.)

SHEET METAL PARAPET

COPING

STANDING SEAM METAL CAP

WITH CONTINUOUS CLEAT

ON THE OUTSIDE CRIMPED

AT 45 DEGREES

CANT STRIP

3/4" EXT. GRADE PLYWOOD

TOP AND BOTTOM OF

NAILERS

BASE SHEET AS REQUIRED

CONT. CLEAT

CONT. 2X6 WOOD

SHIM FORM TOP FOR

SLOPE

CONT. 1X4 WOOD

SHIM FORM TOP FOR

SLOPE

3/4" EXTERIOR GRADE

F.R. PLYWOOD

1- 1/

2" M

IN

PLY SHEET FLASHING

M

IN

IM

U

M

'-0

18" MAX.

8"

CLAD METAL RECIVER

TERM BAR

FLASHING

CONT. CLEAT

REMOVABLE SHEET METAL

COUNTERFLASHING

REGLET RECIVER

FASTENERS APPROX. 24"

O.C.

CANT

EXISTING WALL

EXTENDED FIELD PLIES ABOVE

HEAD OF CANT STRIP

FIELD SHEET

ROOF DECK

THERMAL INSUL.

COVERBOARD

8"

BASE SHEET AS REQUIRED

SEALANT

FASTENED APPROX. 8"

O.C. 3 COURSE AND

MASTIC

PLY SHEET FLASHING

PLY SHEET

FLASHING

ROOF DECK

THERMAL INSULATION

COVERBOARD

PLY SHEET

EXTEND FIELD PLIES ABOVE

HEAD OF CANT

REMOVABLE

SHEET METAL

COUNTER

FLASHING

3" LAP AT JOINTS

EXISTING METAL

REGLET TO REMAIN

FASTENERS

APPROX. 24"

O.C.

CONT. CLEAT

PRIME WALL

EXISTING METAL

PANEL TO REMAIN

" M

IN

PREFINISHED METAL

RECEIVER TRIM

FASTENERS AT 12"

O.C. IN SEALANT

CANT STRIP

FIELD SHEET

BASE SHEET AS REQUIRED

PLY SHEET FLASHING

FASTENED APPROX. 8" O.C. 3

COURSE AND MASTIC

3/4" EXT. F.R.

PLYWOOD

STRUCTURE

PREFINISHED METAL

RECEIVER TRIM

FLASHING

CONT. CLEAT

REMOVABLE SHEET METAL

COUNTERFLASHING

PREFINISHED SHEET METAL

EXPANSION JOINT COVER

FASTENED 8" O.C. SEALED WITH 3

COURSE AND MASTIC

WOOD CANT TO BRACE CURB

FLEXIBLE VAPOR RETARDER

WITH COMPRESSIBLE INSUL.

EXTENDED FIELD PLIES ABOVE

HEAD OF CANT STRIP

PLY SHEETROOF DECK

THERMAL INSULATION

COVERBOARD

FIELD SHEETBASE SHEET IF REQUIRED

PLY SHEET FLASHING

" M

AX

EXISTING TO REMAIN

REMOVABLE SHEET METAL

COUNTERFLASHING

EXTEND BASE

FLASHING UP AND OVER

PARAPET

CONT 2X6 WOOD SHIM FORM TOP

FOR SLOPE

CONT 1X4 WOOD SHIM FORM TOP

FOR SLOPE

3/4" EXTERIOR GRADE F.R. PLYWOOD

TOP AND BOTTOM OF NAILERS

FLASHING MEMBRANE

FLEXIBLE VAPOR RETARDER

WITH COMPRESSIBLE

INSULATION

SELF-ADHERED MEMBRANE

SHEET CLOSURE SECURED TO

WALL WITH TERM BAR & 3

COURSE MASTIC ENSURING

PROPER OVERLAP

FASTENERS APPROX.

24" O.C.

SHEET METAL

RECEIVER

SLOPE

3" LAP AT JOINTS TYP.

PREFINISHED SHEET

METAL RECEIVER

EXTEND FLASHING UP

AND OVER PARAPET

CONTINUOUS CLEAT

ROOF DECK

THERMAL INSULATION

COVERBOARD

PLY SHEET

EXTEND FIELD PLIES

ABOVE HEAD OF CANT

PRIME WALL WHEN

APPLICABLE

CANT STRIP

3/4" EXTERIOR F.R.GRADE PLYWOOD

PLY SHEET FLASHING

FIELD SHEETBASE SHEET AS REQUIRED

CONTINUOUS BEAD OF SEALANT

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

ROOF DETAILS

25-1183-49 10/07/2025

AA/JK

R2.01

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

NOT TO SCALE1 MEDIUM PARAPET

NOT TO SCALE2 LOW PARAPET

NOT TO SCALE4 RAISED METAL EDGE

NOT TO SCALE5 METAL EDGE

NOT TO SCALE9 RISEWALL - CMU TILT WALL

NOT TO SCALE6 RAISED METAL EDGE WITH COPING

NOT TO SCALE11 FIELD EXPANSION JOINT

M U

LT

IP

LE

B

U

IL

D

IN

G S

C

AN

YO

N

, T X

NOT TO SCALE3 TALL SLANTED PARAPET

NOT TO SCALE10 RISEWALL - BRICK

NOT TO SCALE8 RISEWALL - METAL PANEL

NOT TO SCALE7 RISEWALL - EIFS

NOT TO SCALE12 PARAPET EXPANSION JOINT TO BRICK RISEWALL

8" N

O M

IN

AL

FL

AS

H

IN

G H

EI

G

H T

FIELD SHEET

FLASHING

COVERBOARD

THERMAL INSUL.ROOF DECK

EXTEND FIELD PLY ABOVE

HEAD OF CANT STRIP

FASTENERS APPROX. 8" O.C.

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 18" O.C.

DEPENDING UPON WIND ZONE AND

LOCAL CONDITIONS)

BEVEL TOP OF BOTH WOOD

CURBS TO DRAIN TO ONE SIDE

WOOD CANT TO BRACE CURB

WOOD NAILERS

EXTEND BASE FLASHING

UP AND OVER WOOD

BLOCKING

COMPRESSIBLE

INSUL.

EQUAL

TO EJ

2"

FLEXIBLE VAPOR RETARDER

TO SERVE AS INSUL.

RETAINER (ATTACHED TO

TOP OF CURB)

PLY SHEET

PLY SHEET FLASHING

BASE SHEET IF REQUIRED

FLASHING MEMBRANE

COVER PLATE

A - SECTION CONT. VERT. CLEAT

METAL COVER

PROVIDE FOR EXPANSION

ON ONE SIDE

A

A

STANDING SEAM JOINT

SHEET METAL EXPANSION

JOINT COVER

FLEXIBLE WATERPROOF

MEMBRANE CLOSURE

RAISE CONT. THROUGH WALL

FLASHING TO STEP UP BEHIND

CONTROL JOINT COVER PLATE

PLACE THERMOPLASTIC BOOT FROM

THROUGH WALL FLASHING UP AND OVER

PARAPET. PROVIDE BELLOWS OVER

EXPANSION JOINT.

CONT. CLEAT VERT.

EACH SIDE OF JOINT

8" N

O M

IN

AL

FL

AS

H

IN

G H

EI

G

H T

EXTEND BASE FLASHING UP AND OVER WOOD BLOCKING

FLEXIBLE VAPOR TO RETARDER TO SERVE AS INSUL. RETAINER

(ATTACHED TO TOP OF CURB)

COMPRESSIBLE INSUL.

ROOF DECK

BASE SHEET IF REQUIRED

THERMAL INSUL.

COVERBOARD

WOOD CANT TO

BRACE CURB

NAILERS

PLY SHEET

FIELD SHEET

FASTENERS AT 8" O.C. SEAL

TOP OF FLASHING WITH A

3-COURSE OF VERTICAL

GRADE PROOF CEMENT AND

REINFORCEMENT FABRIC

PLY SHEET

FLASHING

FLASHING

SLOPE

END CLOSURE

CONTINUOUS VERTICAL

CLIP WITH SLIP-ON

VERTICAL FLASHING

EXTEND FLEXIBLE MEMBRANE

OVER TO VERTICAL EXPANSION

JOINT AND INSTALL

PERFORMED END DAM AT

INTERSECTION

A

A - SECTION

DSA TAPE

VERTICAL

TERM BAR

SEALANT

HEMMED EDGE

S. S. METAL FLASHING

SLOPE

A

SHEET METAL

GUTTER

GUTTER BRACKET

SUPPORT AT 12" TO

36" O.C., FLEXIBLE

MEMBRANE

CLOSURE; EXTEND

INTO GUTTER

GUTTER SPACER

ALTERNATELY

SPACED FROM

BRACKETS

FASTENERS AT

APPROX. 3" O.C.

STAGGERED

FLASHING

PLY SHEET

COVERBOARD

THERMAL INSUL.

ROOF DECK

WOOD NAILERS

2 PIECE CONTINUOUS SHEET METAL

CLOSURE FASTENED APPROX. 18" O.C.

EXTEND ONE PLY OR A

SEPARATE MEMBRANE SHEET

TO OVERLAY METAL CLOSURE

FIELD SHEET

PLY SHEET

FLASHING

SHEET METAL EDGE

FLASHING; PRIME

FLANGE BEFORE

STRIPPING

BASE SHEET

AS REQUIRED

SET SCUPPER IN

FULL BED OF MASTIC

24 GAUGE CLAD METAL

SCUPPER - SHOP

FABRICATED - SOLDER ALL

JOINTS CONT. TO ENSURE

WATER TIGHTNESS

HEM EDGE OF

FLANGE 3/4" MIN.

ON ALL SIDES

6" MIN.

1- 1/

2" 8"

MEMBRANE FLASHING

FIELD SOLDER AROUND

ENTIRE FACE CONNECTION

OF SCUPPER BOTH SIDES

EXTEND BASE FLASHING INTO

SCUPPER AT MIN. OF 3" ON

BOTTOM AND HEAT WELD ALL

SIDES.

FIBER CANT STRIP AS SPEC.

CONT. ALONG WALL WHERE

SCUPPER OCCURS

CUT EXCESS C/F FROM

PERIMETER OF SCUPPER

WALL STRUCTURE

TO REMAIN

REFER TO PARAPET

DETAIL FOR FURTHER

COPING AND FLASHING

INFORMATION

PRIME WALL WHEN

APPLICABLE

EXTEND FLASHING

UP AND OVER

WOOD BLOCKING

REFER TO SPECIFICATIONS

FOR PARAPET WALL

APPLICATION PROCEDURES

STRIP IN PLY HOT AIR WELD

TO THERMOPLASTIC EIP

SHEET AROUND PENETRATION

STANDING SEAM METAL CAP

SCUPPER - TYP. EXT. ELEVATION

NOT TO SCALE

1 1/2"12"

1/

2" 8"

1/

2"

1 1/2"

2"

WALL SURFACE

SET SCUPPER FACE

W/ RUBBER BACKER &

CAULK ON ALL SIDES

EXPANSION BOLT

ROOF LINE BEYOND

PREFINISHED 24 GAUGE

SCUPPER FASTEN TO

FACE OF WALL WITH E.B.

HEM THE FLANGE EDGE

3/4" ON ALL SIDES

SOLDER FLANGE TO TOP

WOOD NAILERS

ROOF DECK

MEMBRANE INSTALLED OVER

SCUPPER FLANGE AND HEAT

WELDED TO SCUPPER AND

FIELD MEMBRANE

THERMAL INSULATION

COVERBOARD

FLOW LINE MINIMUM 2",

MAX 4" ABOVE FINISHED

ROOF SURFACE.

BASE SHEET IF REQUIRED

6" MIN.

1- 1/

2" 5"

1 1/2"12"

1 1 /2"

8" 1 1

/2"

1 1/2"

2"

HEM THE FLANGE EDGE

3/4" ON ALL SIDES

SOLDER FLANGE TO TOP

SET SCUPPER IN FULL

BED OF MASTIC

24 GAUGE PREFINISHED

SCUPPER - SHOP

FABRICATED - SOLDER

ALL JOINTS CONT. TO

ENSURE WATER

TIGHTNESS

HEM EDGE OF FLANGE

3/4" MIN. ON ALL SIDES

FIELD SOLDER AROUND

ENTIRE FACE

CONNECTION OF

SCUPPER BOTH SIDES

EXTEND BASE FLASHING

INTO SCUPPER AT MIN.

OF 3" ON BOTTOM AND

SEAL ALL SIDES WITH

STRUCTURAL SEALANT

CUT EXCESS C/F FROM

PERIMETER OF SCUPPER

WALL SYSTEM TO

REMAIN

PRIME WALL

EXTEND FLASHING UP

AND OVER WOOD

BLOCKING

STRIP IN PLY HOT AIR

WELDED AROUND

PENETRATION

ABRADE AND PRIME METAL FLANGE

STANDING SEAM METAL

CAP

SCUPPER - TYP. EXT. ELEVATION

NOT TO SCALE

WALL SURFACE

SET SCUPPER FACE

W/ RUBBER BACKER

& CAULK ON ALL

SIDES

EXPANSION BOLT

ROOF LINE BEYOND

PREFINISHED 24 GAUGE

SCUPPER FASTEN TO

FACE OF WALL WITH E.B.

ROOF MEMBRANE - REF. TYP.

DETAIL

BASE FLASHING

REFER TO PARAPET DETAIL FOR

FURTHER COPING AND FLASHING

INFORMATION

3'-6"

MEMBRANE FIELD PLIES AND STRIPPING

PLIES ALL EXTEND UNDER CLAMPING RING

DRAIN BOWL

DECK CLAMP

CLAMPING RING

ROOF DECK

THERMAL INSUL.

FLASHING

COVERBOARD

SEE LAYOUT DETAIL FOR

SUMP AROUND BOTH DRAINS

DRAIN STRAINER

PRIMARY ROOF

DRAIN

FLASHING

SEE LAYOUT DETAIL

FOR SUMP AROUND

BOTH DRAINS

OVERFLOW DRAIN

DRAIN STRAINER

2" HIGH PLASTIC RING

INSERT

INSULATION

ROOF DECK

CLAMPING RING

DECK CLAMP

DRAIN BOWL

MEMBRANE FIELD PLIES AND STRIPPING PLIES ALL EXTEND

UNDER CLAMPING RING

PLY SHEET

WATER BLOCK

30" SQUARE MIN., 4 LB. LEAD IN ROOF CEMENT, PRIME

TOP SURFACE BEFORE STRIPPING - TURNED INTO DRAIN

BOWL 1" MIN.

ODRD

SL

O

PE

SLOPE

SL

O

PE

PARAPET WALL

OVERFLOW ROOF

DRAIN

TAPER CRICKETS

BETWEEN DRAINS REFER

TO ROOF PLAN

4'-0" X 8'-0" SUMP

AROUND BOTH

DRAINS

PRIMARY ROOF

DRAIN

VALLEY BETWEEN

DRAINS

SLOPE

TAPER PLAN

PLY SHEET FLASHING

BASE SHEET AS REQUIRED

FIELD SHEET

PLY SHEET FLASHING

48"

ROOF DECK

FIELD SHEET

FLASHING

DRAIN STRAINER

THERMAL INSUL.

CLAMPING RING

DECK CLAMP

DRAIN BOWL

WATER BLOCK

MEMBRANE FIELD PLIES, METAL

FLASHING, AND STRIPPING

PLIES ALL EXTEND UNDER

CLAMPING RING

RD

48"X48" SUMP AROUND

DRAIN

PRIMARY ROOF

DRAIN

TAPER CRICKETS

BETWEEN DRAINS

SL

O

PE

SLOPE

SL

O

PE

SLOPE

TAPER PLAN

30" SQUARE MIN., 4 LB. LEAD

FLASHING SET ON FINISHED

ROOF IN ROOF CEMENT, PRIME

TOP SURFACE BEFORE

STRIPPING

COVERBOARD

PLY SHEET

PLY SHEET FLASHING

BASE SHEET

IF REQUIRED

" M

IN

FL

AS

H

IN

G H

EI

G

H T

FLASHING

FIELD SHEET

PLY SHEET

COVERBOARD

THERMAL INSUL.

ROOF DECK

PLY SHEET FLASHING

EXTEND FIELD PLIES ABOVE

HEAD OF CANT STRIP

FASTENERS

BEVEL TOP OF BOTH WOOD

CURBS TO DRAIN TO ONE SIDE

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

WOOD CANT TO BRACE CURB

EACH SIDE

WOOD NAILERS

4"

4"

BASE SHEET AS REQUIRED

INSULATION

FLASHING

FIELD SHEET

PLY SHEET

PLYSHEET FLASHING

COVERBOARD

THERMAL INSULATION

BASE SHEET AS REQUIRED

ROOF DECK

EXTEND FIELD PLIES ABOVE HEAD

OF CANT

FASTENERS

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

UNIT MOUNTING CURB

SEALING MATERIAL

WOOD NAILER

REMOVABLE SHEET METAL

COUNTERFLASHING

CANT STRIP

MECHANICAL UNIT

SEALING MATERIAL- MUST

BE CONTINUOUS ON TOP

OF THE CURB

FASTENER

WOOD NAILER

SLIP FLASHING

UNIT MOUNTING CURB

CANT STRIP

FASTENERS NOTES:

1. THE CURB'S TOP WOOD NAILER, AND SEAL STRIP

ARE TO BE SUPPLIED BY THE CURB

MANUFACTURER.

2. ATTACH NAILER TO DECK WITH SUITABLE

FASTENERS.

3. WHEN POSSIBLE, THE MECHANICAL UNITS

SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE

AND FLASHING HAVE BEEN INSTALLED.

N O

M

IN

AL

FL

AS

H

IN

G

H

EI

G H

T

WOOD NAILERS

INSULATED ROOF HATCH

INSULATION

FLASHING

FIELD SHEET

COVERBOARD

THERMAL INSULATION

EXTEND FIELD PLIES UP CURB 4" MIN

TERMINATION BAR SECURED AT 8" O.C.

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

ROOF HATCH CURB

SEALING MATERIAL

REMOVABLE SHEET METAL

COUNTERFLASHING

ROOF HATCH

SEALING MATERIAL- MUST

BE CONTINUOUS ON TOP

OF THE CURB

FASTENER

WOOD NAILER

SLIP FLASHING

UNIT MOUNTING CURB

FASTENERS

NOTES:

1. THE CURB'S TOP WOOD NAILER, AND SEAL STRIP ARE TO BE

SUPPLIED BY THE CURB MANUFACTURER.

2. ATTACH NAILER TO DECK WITH SUITABLE FASTENERS.

3. WHEN POSSIBLE, THE ROOF HATCH SHOULD NOT BE SET

UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN

INSTALLED.

N O

M

IN

AL

FL

AS

H

IN

G

H

EI

G H

T

WOOD NAILERS

ROOF HATCH SEAL

ROOF HATCH CURB

INSULATION

CANT STRIP

PLY SHEET

ROOF DECK

PLY SHEET FLASHING

NO BASE SHEET AS REQUIRED

R2.01

R2.01 JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

ROOF DETAILS

25-1183-49 10/07/2025

AA/JK

R2.02

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

NOT TO SCALE1 FIELD EXPANSION JOINT TO PARAPET

NOT TO SCALE2 2 WAY EXPANSION JOINT

NOT TO SCALE3 3 WAY EXPANSION JOINT - BRICK CORNER

NOT TO SCALE4 METAL EDGE GUTTER

NOT TO SCALE5 OVERFLOW SCUPPER

NOT TO SCALE6 PRIMARY SCUPPER

NOT TO SCALE7 PRIMARY AND OVERFLOW DRAINS

NOT TO SCALE8 PRIMARY DRAIN

NOT TO SCALE9 EQUIPMENT CURB

NOT TO SCALE10 MECHANICAL CURB

NOT TO SCALE11 ROOF HATCH

M U

LT

IP

LE

B

U

IL

D

IN

G S

C

AN

YO

N

, T X

FLASHING

COVERBOARD

TERM BAR FASTENED

APPROX. 8" O.C.

NEW REMOVABLE SHEET METAL

COUNTERFLASHING

HIGH-DOMED, CAPPED GASKETED

FASTENERS (APPROX. 18" O.C., DEPENDING

UPON WIND ZONE AND LOCAL CONDITIONS

MIN. TWO FASTENERS PER SIDE)

FIELD SHEET

KALWALL SKYLIGHT

ASSEMBLY SYSTEM

STUD FRAMING

RIGID INSUL.

3/4" F.R. PLYWOOD

ANGLE SUPPORT

2 X WOOD

PLY SHEET FLASHINGCANT STRIP

PLY SHEET

ROOF DECK

THERMAL INSUL.

4" MINIMUM

4" MINIMUM

6" MIN. FLANGE

FIELD SHEET

FLASHING

SET FLANGE IN ROOF CEMENT-

PRIME FLANGE BEFORE STRIPPING

ROOF DECK

THERMAL INSUL.

COVERBOARD

PLY SHEET FLASHING

STRUCTURAL SEALANT AT

PENETRATION TO MEMBRANE

JUNCTURE

PLUMBING VENT STACK

SOFT METAL PIPE FLASHING

TOP OF FLASHING CAPPED OR

ROLLED INTO PIPE APPROX. 1"

PLY SHEET

BASE SHEET AS REQUIRED

" N

O M

IN

AL

FL

AS

H

IN

G H

EI

G

H T

FLASHING

FIELD SHEET

MIN. 4" CLEARANCE FORM

PIPE TO TOP OF CURB;

MIN. 2" BETWEEN PIPES

WOOD NAILERS

AND CURB

WOOD CANT TO

BRACE CURB

ROOF DECK

BASE SHEET IF REQUIRED

THERMAL INSUL.

COVERBOARD

PLY SHEET

PLY SHEET FLASHING

FASTENERS

EXTEND FIELD PLIES ABOVE HEAD

OF CANT

REMOVABLE SHEET METAL

COUNTERFLASHING

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

SHEET METAL ENCLOSURE-

CROSSBREAK OR SLOPE FOR

DRAINAGE

INSULATE VOID TO PREVENT

CONDENSATION

SHEET METAL OR FLEX-TUBE

COLLAR

SLOPE PIPES DOWN AND AWAY

FROM HOOD

SHEET METAL FLASHING

RECEIVER

PROVIDE INSULATION IN

GAP TO SEPARATE

ABOVE ROOF AND

CEILING PLENUM

SLOPE

EXTEND FIELD PLY ABOVE

HEAD OF CANT

DRAWBAND OR WELD UMBRELLA

TO STACK

COVERBOARD

VARIES

N O

M

IN

AL

FL

AS

H

IN

G

H

EI

G H

T

FLASHING

FIELD SHEET

ROOF DECK

THERMAL INSULATION

HIGH-DOMED, CAPPED, GASKETED

FASTENERS (APPROX. 12" O.C.)

WOOD NAILER AND CURB

INSULATE VOID FOR COLD

STACKS

TEMPERATURE APPROPRIATE

ELASTOMERIC SEALANT

METAL OR

GYPSUM LINER

IF REQUIRED

REMOVABLE SHEET METAL

COUNTERFLASHING

WOOD CANT TO BRACE CURB

BASE SHEET

PLY SHEET

PLY SHEET FLASHING

FASTENERS

ROOF DECK

COVERBOARD

FIELD SHEET

THERMAL INSUL.

BASE SHEET

IF REQUIRED

24" MAX

2 1/2" MIN BEARING

PLY SHEET

TEK5 ANCHORS AT ALL CORNERS

8" MAX O.C.

3/16" PLATE STEEL

EXISTING HOLE

FIELD SHEET

PLY SHEET

24" TO 60"

COVERBOARD

THERMAL INSULATION

ROOF DECK

BASE SHEET AS

REQUIRED

EXISTING ANGLE

IRON

NEW ANGLE IRON

BOLTED 24" O.C.

5/8" DENS-DECK

METAL DECK -

SCREWED TO

ANGLE IRON 6" O.C.

DOUBLE ANGLE

IRON WELDED TO

ANGLE FRAME

CONT. BEAD OF SEALANT BOTH

SIDES

CONT. CLEAT BOTH SIDES

DOG EARED LOW PROFILE STANDING

SEAM JOINT 16" AWAY FROM EDGE

PREFINISHED GALVANIZED COPING CAP

TREATED WOOD NAILERS,

SLOPED TO DRAIN

SELF ADHERED MEMBRANE

OVER WOOD NAILERS

EXISTING WALL

4" MIN. FLANGE, SET IN ROOF

CEMENT OVER ROOFING PLIES,

PRIME FLANGE BEFORE

STRIPPING

STRUCTURAL SEALANT

AT PENETRATION TO

MEMBRANE JUNCTURE

SHEET METAL PITCH PAN,

SOLDERED/ WELDED

WATERTIGHT (4" MIN.

HEIGHT)

SHEET METAL DUCT

THROUGH ROOF AND

EXTEND ABOVE TOP OF

PENETRATION SLEEVE

SHEET METAL DUCT

OVER PENETRATION

SLEEVE AND ATTACH

THROUGH SIDE WITH

GROMMETED FASTENERS

FLASHING

ROOF DECK

COVERBOARD

FIELD SHEET

THERMAL INSUL.

PLY SHEET

OPTIONAL: WOOD NAILERS; VARIES

DEPENDING UPON SIZE OF

PENETRATION.

BASE SHEET

IF REQUIRED

PLY SHEET FLASHING

FLASHING

CONT. CLEAT

REMOVABLE SHEET METAL

COUNTERFLASHING

3" LAP AT JOINT TYP.

3" LAP WITH BEAD OF

SEALANT

PREFINISHED SHEET

METAL EXPANSION JOINT

COVER

FASTENED 8" O.C. SEALED

WITH 3 COURSE AND

MASTIC

WOOD CANT TO BRACE

CURB

FLEXIBLE VAPOR RETARDER

WITH COMPRESSIBLE INSUL.

EXTENDED FIELD PLIES ABOVE

HEAD OF CANT STRIP

SELF-ADHERED MEMBRANE SHEET

CLOSURE SECURED TO WALL WITH

TERM BAR & 3 COURSE MASTIC

ENSURING PROPER OVERLAP

EXTEND BASE FLASHING UP AND

OVER WOOD BLOCKING

FIELD SHEETS

ROOF DECK

THERMAL INSULATION

COVERBOARD

8"8" M

IN

EJ WIDTH

BASE SHEET IF REQUIRED

PLY SHEET FLASHING

PLY SHEETS

REGLET RECIVER

FASTENERS APPROX. 24"

O.C.

SEALENT

SLOPE OUTWARD

FLASHING

BASE SHEET IF REQUIRED

THERMAL INSULATION

COVERBOARD

PLY SHEET FLASHING

FIELD SHEET

EXTEND FIELD PLIES ABOVE HEAD

OF CANT

PRIME WALL WHEN APPLICABLE

CONT. CLEAT, 20 GA.

SHEET METAL REGLET/RECEIVER

REMOVABLE PREFINISHED SHEET

METAL COUNTERFLASHING

CANT STRIP

8" M

IN

WINDOW SYSTEM

ROOF DECK

PLY SHEET

PLY WOOD

FLASHING

ROOF DECK

THERMAL INSUL.

COVERBOARD

PLY SHEET

FIELD SHEET

PLY SHEET FLASHING

4" MIN. FLANGE, SET IN ROOF CEMENT

OVER ROOFING PLIES, PRIME FLANGE

BEFORE STRIPPING

STRUCTURAL SEALANT AT PENETRATION

TO MEMBRANE JUNCTURE

SHEET METAL PITCH PAN, SOLDERED/

WELDED WATERTIGHT (4" MIN. HEIGHT)

WATERTIGHT 24 GA. METAL RAIN COLLAR

OVERLAPPING PENETRATION POCKET

DRAW BAND

SEALANT

APPROX. 1/4" CLEARANCE

BETWEEN EA. CORNER

AND EDGE OF COLLAR

POURABLE SEALANT

1" MIN. PIPE

DIAMETER

OPTIONAL: WOOD NAILERS; VARIES

DEPENDING UPON SIZE OF

PENETRATION.

BASE SHEET IF REQUIRED

STRUCTURAL SEALANT AT PENETRATION TO

MEMBRANE JUNCTURE

NEW STAINLESS STEEL PITCH PAN

NEW WATERTIGHT STAINLESS STEEL RAIN

COLLAR OVERLAPPING PENETRATION

POCKET

NEW STAINLESS STEEL

DRAW BAND

SEALANT

APPROX. 1/4" CLEARANCE BETWEEN EA.

CORNER AND EDGE OF COLLAR

SELF-LEVELING

SEALANT

EXISTING GUY SUPPORT ANCHOR

FLASHING

FIELD SHEET

PLY SHEET

COVERBOARD

THERMAL INSULATION

EXISTING ROOF DECK

PLY SHEET FLASHING

JOB:

DATE:

DRAWN BY:

TEXAS REGISTERED

ENGINEERING FIRM F-6498

2505 79TH ST., SUITE A

LUBBOCK, TEXAS 79423

(972) 874-1388

IN

D U

ST

R

IE

S, IN

C

ARMKO

CONTRACTOR SHALL VERIFY ALL

SUBSTRATES, DIMENSIONS,

CURBS, PENETRATIONS, ECT.

THOSE SHOWN ARE TYPICAL BUT

MAY NOT BE ALL INCLUSIVE

Copyright 2025 by Armko Industries

ISSUES

CHECKED BY:

THIS DOCUMENT WAS

PRODUCED BY OR UNDER

THE DIRECT SUPERVISION

OF REGISTERED ENGINEER

REVISIONS

ISSUE DATE:

Issue For Construction 10/07/2025

ROOF DETAILS

25-1183-49 10/07/2025

AA/JK

R2.03

PR

O

JE

C

T

FO

R

W

ES

T

TE

XA

S

A& M

U N

IV

ER

SI

TY

R O

O F

R

EP

LA

C

EM

EN

T

PR

O

JE

C T

CB

01/20/2026

NOT TO SCALE1 SKYLIGHT KALWALL

NOT TO SCALE2 VENT STACK

NOT TO SCALE3 PIPE BOX

NOT TO SCALE4 HOT STACK

NOT TO SCALE5 DECK INFILL 24" AND LESS"

NOT TO SCALE6 DECK INFILL 24"-60"

M U

LT

IP

LE

B

U

IL

D

IN

G S

C

AN

YO

N

, T X

NOT TO SCALE7 COPING CAP

NOT TO SCALE8 ROOF DUCT

NOT TO SCALE9 RISEWALL EXPANSION JOINT - BRICK

NOT TO SCALE10 RISEWALL AT WINDOW

NOT TO SCALE11 PITCH PAN

NOT TO SCALE12 RISEWALL AT WINDOW

File details come from the government source that posted it. Updated .