PANAM 101.pdf

PDF 903 KB Posted

Attached to
Z2DA--CFM - Rebalance HVAC System Federal contract opportunity
Solicitation number
Not on record
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

About this file

This document package contains mechanical ductwork plans and specifications for rebalancing the HVAC system at a Department of Veterans Affairs medical facility. Key details include duct sizing and layout for the first floor, technical specifications for duct installation and balancing, and over 90 attachments providing additional requirements. The related federal contract opportunity is a solicitation to hire a contractor to perform the HVAC rebalancing work according to the specifications, with the goal of improving air flow and temperature control across the medical center. Relevant details such as response dates and pricing terms are not provided.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--CFM - Rebalance HVAC System, newest first.
File Type Posted
VAV DNT 02303-2MH628.pdf PDF
P12-AMS CEP 115-7MH608.pdf PDF
S02-XHIBIT B PAST AND PRESENT PERFORMANCE QUESTIONNAIRE v2.pdf PDF
VAV DNT 02305-2MH630.pdf PDF
DNT L05 G.pdf PDF
RESEARCH 4th mech plan.pdf PDF
CEP L03.pdf PDF
P12-000110 Table of Contents 4-7-20.pdf PDF
AMS TLR 03470-6MH604.pdf PDF
ICRA ILSM for CFM - Rebalance HVAC System.xlsx XLSX spreadsheet
013526 Safety Requirements.pdf PDF
VAV DNT 02302-2MH627.pdf PDF
OUT L08.pdf PDF
S02-EXHIBIT A PERFORMANCE RELEVANCY SURVEY v2.pdf PDF
PANAM 104.pdf PDF
03503-6EP103-M3.pdf PDF
OUT L06.pdf PDF
OUT L04.pdf PDF
OUT L03.pdf PDF
S02-EXHIBIT E SURETY FORM.pdf PDF
P15-M-2 DNT Building Existing AHU sequence.pdf PDF
AMS Research 348-8MH609.pdf PDF
P14-M-4 OP Building Existing AHU sequence.pdf PDF
P15-M-5 OP Building Existing DOAS sequence.pdf PDF
OUT L02.pdf PDF
VAV Research 352-8MH613.pdf PDF
RESEARCH 5 dixie penthouse.pdf PDF
INP L03.pdf PDF
DNT L02i F-G.pdf PDF
PANAM 103.pdf PDF
230593 Testing Adjusting and Balancing for HVAC.pdf PDF
VAV DNT 02301-2MH626.pdf PDF
M-3 DNT Building Existing DOAS sequence.pdf PDF
OUT L07.pdf PDF
P13-INP L04.pdf PDF
DNT L01i D-E.pdf PDF
230511 Common Work Results for HVAC.pdf PDF
RESEARCH 2nd mech plan.pdf PDF
OUT L05.pdf PDF
390-8EP105-P.pdf PDF
S02-EXHIBIT D CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY v2.pdf PDF
PANAM 105.pdf PDF
P07-General Decision.pdf PDF
CEP L04.pdf PDF
230800 Commissioning of HVAC Systems.pdf PDF
RESEARCH 1st mech plan.pdf PDF
P15-M-1 Typical Existing Service Bay layout.pdf PDF
AMS PANAM 0243-9MH601.pdf PDF
AMS OP 03027-3MH604.pdf PDF
010000 General Requirements.pdf PDF
Show all 50

Z2DA--CFM - Rebalance HVAC System has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

14x14

EXHAUST UP

R

FD

FD

D x1 x1

D x1

R x1

14x14

D

D 12x10

D x1

8ø

12ø

12ø34x16

R

D

D 8ø

14x14

D D

14x8

D

D

8ø

8ø 8ø x1

D

12x12

24x16

20x18

8ø

8ø 8ø

R

R

12x8

FCU-2

09-1Q

10x14

8ø

8ø

8ø

14x8

S-1 09-1Q

S-2 09-1Q

S-3 09-1Q

S-5 09-1Q

S-6 09-1Q

S-7 09-1Q

S-11 09-1Q

S-10 09-1Q

S-9 09-1Q

S-13 09-1Q

S-14 09-1Q

S-15 09-1Q

S-16 09-1Q

S-17 09-1Q

S-18 09-1Q

S-19 09-1Q

S-26 09-1Q

S-21 09-1Q

14x14

14x14

D D

SD-38

SD-38

400RG-38

RG-38

SD-38

SD-38

RG-38

SD-38

34x16 SUPPLY DUCT DN AND TRANSITION/OFFSET TO 16x34 DN

24x16 RETURN DUCT DN AND TRANSITION TO 16x24

DN.

SD-38

SD-38

SD-38

SD-38

SD-37

SD-37

SD-38

SD-38

(2)RG-38

SD-38

SD-38

(2)RG-38

SD-38

SD-38

SD-37

SD-37

(4)SD-37

(TYP. FOR 6)

SD-37

RG-38

RG-38

SD-37

SD-37

SD-37

SD-38

SD-38

SD-38

SD-38

x1

150150

SD-38

SD-37

SD-38

2508ø

D 24x16 RETURN DUCT DN AND TRANSITION TO 16x24

DN.

SD-37

SD-37

17512x10

SD-37

SD-37

SD-37

D

R

12x6

8ø

8ø

(2)RG-37

RG-37

S-23 09-1Q

S-22 09-1Q

S-4 09-1Q

SD-37

SD-37

8ø

SD-38

SD-38

SD-37

RG-37

12ø

SD-37

STAIR

STQ-1

STAIR

STQ-2

ELEC./AV

1Q126

CONF

1Q132

CONF

1Q130

CONF

1Q135

PANTRY

1Q129

CONF

1Q137

AUDITORIUM

1Q136

MALE

1Q118

FEMALE

1Q113

PREFUNCTION SPACE

1Q134

MANAGER

1Q105

SUPERVISOR

1Q108A LOAN OFFICER

1Q108B

VAULT

1Q109

ATM

1Q127

SUPPLIES

1Q112

LOBBY

1Q108

OFFICE

1Q115

CLASSRM

1Q116

RECEPT

1Q114A

SEATING

1Q114B

COMPUTERS

1Q114F

AV

1Q114E

CLASSROOM

1Q104

SIM LAB

1Q100

CLASSROOM

1Q102

SERVICE WINDOW

1Q110

PERIODICALS

1Q114C

ADMIN.

1Q114D

TELECOM

1Q140

ELEC

1Q111

TELECOM

DEMARCATION

1Q103

SUPPLIES

1Q119

IT CLASSRM

1Q121

IT CLASSRM

1Q122

IT SUPPLIES

1Q120

EMER ELEC

1Q111A

CAFE

1Q125

ACOS

1Q123B

STAIR

STQ-4

STAIR

STQ-3

WRKSTN

1Q107

HK

1Q131

CHILLED WATER PUMP

1Q117

MALE

1Q133

FEMALE

1Q128

SHQ02

CORR

1Q-C01

LOBBY

1Q139

ELEV

QP-1

ELEV

QP-2

SHQ01

SHQ03

LIBRARY

1Q114

SHQ04

SHQ09

PREFUNCTION SPACE

1Q138

CORR

1Q-C06

CORR

1Q-C05

CORR

1Q-C04

CORR

1Q-C03

ELEV

QP-3

SUPPLIES

1Q106

CAFE WRKRM

1Q141

ASST./ WAITING

1Q123A

LVSR

1Q101

ELEV LOBBY

1Q139A

/4

CHAIRS

1Q144

TELEPHONE EQUIP

1Q124

PREFUNCTION SPACE

1Q146

PREFUNCTION SPACE

1Q145

SHQ10 SHQ11SHQ12

SD-37

12ø

10x14

RG-37

12ø

(TYP)

RG-37

12ø (TYP)

SD-37

SD-38

28x16

SD-38

SD-38

8ø

8ø

16x24 SUPPLY DUCT DN

TO TERMINAL UNIT.

RG-37

RG-38

12ø

12x6

12x6

SD-38

SD-38

8ø

8ø

8øR

A

B

D

E

F

G

L

M

1A

F1

K

J

H

RG-34

SD-34

SD-34

R 14x10

16x14

14x12 x1 x1

30x16 RETURN

DUCT DN.

10x12

ONE-WAY

BLOW (TYP.)

D

SD-37

SD-37

RG-34

RG-34

RG-34

RG-34

D 16x8

SD-34

SD-34

SD-34

SD-37

16x24 SUPPLY DUCT DN

TO TERMINAL UNIT.

12ø

R

D

R

D

R

D

12x8

12ø

SD-37

R

12ø

R

26x12 34x12

26x12

SD-34

SD-37

SD-34

SD-34

SD-34

SD-37

16x12 R

D

SD-34

34x12 26x12

26x12

RG-34

RG-34

RG-34

RG-34

18x10

(TYP.)

8ø

SD-38

SD-38

8ø

SD-38

SD-38

RG-34

12x10

18x10

(TYP.)

18x10

(TYP.)

SD-37

12x10

SD-37

D x2 x1

34x1234x12

34x12

10x10

12ø

SD-13

(TYP. FOR 7)

SD-12

SD-13

(TYP. FOR 6)

(TYP. FOR 6)

14x12

RG-14

(TYP. FOR 3)

RG-14

RG-14

(TYP. FOR 3)

(TYP. FOR 3)

SD-12

SD-12

RG-12

RG-12

SD-11

(2)SD-37

SD-12

SD-12

SD-12

D

D

D

R

D R

D R

D

R D

D

D

D

RG-38

8ø

R

10x1214x12

8ø

RG-12

SD-12

SD-12

RG-12

SD-12

8ø

D

14x10

EG-11

RG-14

RG-12

SD-14

SD-12

12ø x1

9ø

18x8

9ø

9ø

9ø 9ø

18x8

9ø

18x8

9ø

SD-12

SD-12

SD-12

SD-12

SD-12

150 SD-12

RG-14

RG-14

SD-13

RG-13

RG-13

SD-13

14x8

14x8

12x8

9ø

9ø

9ø

9ø 9ø

9ø

(6)SD-12

x1 x1 x1 x1

12x8

DR

12x6

12x6

9ø

12x6

14x109ø

10ø

R

R

R

D

D

D x1

34x24 SUPPLY

AIR UP

32x60 RETURN AIR UP 18x52 DN

24x56 SUPPLY AIR UP &

DN

OFFSET IN VERTICAL

D

R

D

RG-38

32x26 SUPPLY AIR UP

32x40 SUPPLY AIR UP &DN

OFFSET IN VERTICAL

32x60 RETURN AIR UP 24x52 DN

10ø

D

R

DR

12ø 12ø

24x12

12x12 14x814x8

14x6

SD-22

SD-22

RG-23

400RG-23

12x6

12x10

R

14x10

EG-21

R

D

R

S-27 09-1Q

S-12 09-1Q

S-25 09-1Q

30x18

FD

FD

FD

FD

S-28 09-1Q

18x8

16x12

RG-13

350SD-13

14x14 x1

8x

S-8 09-1Q

30x16 D x1

S-29 09-1Q x1

S-30 09-1Q x1

48x18

28x18 16x14 x1 x1

28x12

14x8

10ø

FD

FD

x1

424x24 TRANSFER

DUCT ABOVE.

RG-62

SD-62

550 20 x1 x1

RG-12

RG-12

RG-12

12x8 R

6ø10x109ø

18x10

18x10 x1 x8

18x8

18x8

14x8

32x12 EXHAUST UP AND 12x20 DN.

CAC-1

09-1Q

FCU-1

09-1Q

12x6

RG-37

RG-38

8x6

14x14

16x10 x1 x1

6 12 x1 x1

TYP.

TYP.

18x10

TYP.

x1

TYP. TYP.

x1 x1 x1 x1

TYP.

TYP.

x1

10x10

14x6

16x10

14x12

9ø

20x8

12x8

8x6 ø12 ø12

20x16

14x10

12x6

12x12

9ø

14x14 12x12

12ø

TYP.

12x12 12x8

8ø

TYP.

D

48x16

12x10 x2

10ø 10ø

CAC-2

09-1Q x1 x1

30x12

CAC-3

09-1Q

STAND-BY

CAC-4

09-1Q

12ø

16x30 RETURN

DUCT DN.

SD-37

12ø ø12

RG-310

RG-310

SD-23

SD-23

300 RG-24

12x8 ø12

14x6

14x6

SD-64

RG-64

(2)SD-64

RG-64

8ø

12ø

14x10

SD-22

SD-22

20014x6

14x6

RG-15

RG-15

RG-37

20x16

R

8ø

8ø ø8 ø8 ø8 ø8 ø8 ø8 x1

RG-38

12ø ø12

14x10 D

40x18

14x10

14x10

14x16

SD-64

12x12

10øø10 x1

RG-65

FD

22x16

12x8 x2

12x12 12x8 ø12 ø12

R

S-24 09-1Q

12x8

12ø

14x8

12x6

12x6

12x612x6

20x12

18x8

D R

SD-37

S-20 09-1Q

R

EG-12

EG-12

SD-12

SD-12

EG-12

EG-12

EG-12

EG-12

SD-12

10x14

SD-12

x1

14x8

18x10 14x8

16x12

SD-12

SD-12

EG-13

34x16

16x1414x12 14x14 10ø

12x6

EG-12

EG-12

24x10 x6

12x6

SD-37

12x6

RG-310

14x8

RG-310

575 34 x1 x1

30x16

30x16

D

R D x1

D

24x10

14x14

16x14

24x20 SUPPLY DUCT DN AND TRANSITION/OFFSET TO 16x28 DN

8x6

20x18

FD

SD-64

30x12

ACD-TP-D1

ACD-TP-D2

2 2

GENERAL NOTES:

1. FOR SYMBOL LISTS, ABBREVIATIONS, AND GENERAL

NOTES THAT APPLY TO ALL DRAWINGS SEE THE

9MH-0 SERIES OF DRAWINGS.

2. FOR GENERAL DETAILS SEE THE 9MH-5 SERIES OF

DRAWINGS.

3. FOR CONTROL DIAGRAMS SEE THE 9MH-8 SERIES OF

DRAWINGS.

4. FOR VALVE INFORMATION SEE NOTE 27 ON 9MH002.

Key Plan

D

E

F

G

B1

C1

M1 M2

H

J1 J2

N1 N2

B2

C2

Q

K

L

P

A

M3

PLAN

NORTH

SLVHCS

REPLACEMENT MEDICAL CENTER

PROJECT

629-HS2-401

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLE

ARCHITECT/ENGINEERS:CONSULTANTS: OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

NEW ORLEANS, LOUISIANA

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E E

IG

H

T I N

C H

O

N E

F O

O T

O N

E Q

U A

R T

E R

I N

C H

O

N E

F O

O T

O N

E H

A L F

I N

C H

O

N E

F O

O T

T H

R E

E Q

U A

R T

E R

S I N

C H

O

N E

F O

O T

T H

R E

E I N

C H

E S

O

N E

F O

O T

O N

E I N

C H

F

O R

T Y

F E

E T

FULLY SPRINKLERED

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTING ENGINEERS / MECHANICAL, ELECTRICAL & PLUMBING

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

COMMUNICATIONS DESIGN GROUP / LOW VOLTAGE

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC. / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

123456

F

B

A

D

C

E

F

Construction Documents 1

O N

E S

IX

T

E E

N T

H I N

C H

O

N E

F O

O T

O N

E A

N D

O N

E H

A L F

I N

C H

E S

O

N E

F O

O T

BUILDING NUMBER

9MH101-Q

BLDG 9 FIRST FLOOR DUCTWORK PLAN

TA RPBJUNE 7, 2011

EWP_03

1/8" = 1'-0"

01 FIRST FLOOR - Ductwork

1 Addendum # 1 06/17/11

2 Addendum # 2 6/24/11

RFI:00903 - Flex Duct Connections at Annex Sidewall Air Register Plenum Boxes

RFI 01592: Provide access door here for fire dampers.

File details come from the government source that posted it. Updated .