03491-6EL103-M3.pdf
PDF 178 KB Posted
- Attached to
- Z2DA--CFM - Rebalance HVAC System Federal contract opportunity
- Solicitation number
- Not on record
About this file
This document contains a third floor lighting plan for Building 6 at a medical center replacement project located in New Orleans, Louisiana. The plan provides specifications for lighting fixture locations and types throughout Area M3. Key details include lighting notes regarding fixture mounting heights and locations per architectural drawings, occupancy sensor operation and wiring, as well as lighting control requirements involving time schedules, relays, and interfaces with the building automation system. The related federal contract opportunity is an amendment to solicitation number REBALANCE for rebalancing the HVAC system at a Veterans Health Administration facility. The amendment provides ninety-one attachments to the original solicitation.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--CFM - Rebalance HVAC System has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
6E L1
-M
6E
L1
-M
E a b
06 3
06 4
06 5
06 6
M
06 9
XA
06 P 06 R
XB
06 Q06 N
9.5
10.7
06 S
06-3M3
AHU-2
S3 S3
S3
S3
S3
S3
S3
S3
S3
S3
S3
PC
b a 8 b b a
R
TS
TS
b a a a a a a a a b b
ELS6421-29
2#10 & 1#10G-3/4"C
FTR2a
FTR2a
E
E
E
FCZ2c
E
E
E
E
E
ELSL6421-25
ELSL6421-27
ECL6421-21
21 21
E
GENERAL NOTES:
1. REFER TO LEGEND AND GENERAL NOTES ON DRAWING 0ES001.
2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE MOUNTING OF LIGHTING
FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN AND ELEVATIONS PRIOR
TO INSTALLATION.
3. REFER TO LIGHTING FIXTURES SCHEDULE ON DRAWINGS.
4. EXIT SIGNS SHALL BE CONNECTED TO UNSWITCHED EMERGENCY CIRUIT.
5. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL LIGHTING IN MECHANICAL
SPACES AND LOCATE LIGHTING AROUND DUCTWORK AND PIPING TO ALLOW PROPER
ILLUMINATION AND AVOID CONFICTS WITH OTHER TRADES.
6. REFER TO THE RESPECTIVE POWER PLAN FOR PANEL LOCATIONS.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION AND
QUABITY OF FIXTURES.
UNLESS OTHERWISE NOTED, ALL OCCUPANCY SENSORS SHALL BE FIELD
SET FOR VACANCY MODE/MANUAL "ON" VIA LOW VOLTAGE WALL SWITCH.
REFER TO REFERENCE DETAIL FOR SPECIFIC SEQUENCE OF OPERATION.
LIGHTING CONTROL GENERAL NOTES:
1.
OCCUPANCY SENSOR NUMBER DENOTES DETAIL REFERENCE ON
DRAWING 0ES514, E.G. '02' DENOTES DETAIL 2/0ES514. REFER TO
ASSOCIATED DETAIL FOR USE,WIRING, AND CONTROL INTENT.
2.
LOWER CASE LETTER INDICATES ASSOCIATED ROOM CONTROL/SWITCH
LEGS. "Rx" NUMBERS INDICATE ASSOCIATED RELAY CONTROL. REFER TO
LIGHTING CONTROL PANEL SCHEDULES FOR RELAY REQUIREMENTS.
3.
RQUIRED POWER PACKS, ROOM CONTROLLERS, AND LOW VOLTAGE
WIRING AND INTERCONNECTIONS NOT SHOWN ON PLANS. REFER TO
DETAILS, DRAWING 0ES514 AND 0ES515 FOR RQUIREMENTS.
4.
REFER TO LIGHTING CONTROL RISER DIAGRAM AND SCHEDULES FOR
LIGHTING CONTROL PANEL AND RELAY CHANNEL GROUPING
REQUIREMENTS.
5.
ALL TIME SCHEDULED EVENTS SHALL BE INITIATED BY THE BAS VIA
LIGHTING CONTROL PANEL BACNET INTERFACE. LIGHTING CONTROL
RELAYS SHALL DEFAULT TO THE 'ON' POSITION IN THE EVENT OF
NETWORK TROUBLE OR LOSS OF CONNECTION TO THE BAS.
6.
WHERE SHOWN ON PLANS, PUBLIC AREAS SPACES WITH SUFFICIENT
GLAZING SHALL INCLUDE PHOTCELL OVERRIDE TO SHUT OFF INDIVIDUAL
LIGHTING ZONES WHEN DAYLIGHT PENETRATION IS SUFFICIENT. REFER
TO LIGHTING CONTROL PANEL SCHEDULES AND RISER DIAGRAMS FOR
REQUIREMENTS.
7.
CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED MODULES,
INTERFACES, AND CONTROL INTERCONNECTIONS AS REQUIRED BY
MANUFACTURER TO MEET SPACIFIED CONTROL INTENT.
8.
PROVIDE UL924 BYPASS RELAY FOR EACH SWITCHED LIFE SAFETY ZONE.
REFER TO DETAILS ON DWG 7ES507 AND 7ES508.
9.
UNDER NO CIRCUMSTANCES SHALL LINE VOLTAGE LIFE SAFETY WIRING BE
LOCATED WITHIN THE SAME JUCNTION BOX WITH OTHER SYSTEMS WIRING
WITH THE EXCEPTION OF WITHIN UL924 DEVICES.
10.
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
6EL103-M3
BLDG 6 THIRD FLOOR LIGHTING PLAN - AREA
M3
SMAC AVFebruary 29, 2012
6629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
I.S.C. GROUP, INC./ IRRIGATION
DAN EUSER WATER ARCHITECTURE, INC./ WATER FEATURE
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_08
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"
1 6-L3 - Lighting-Area M3
THIS DRAWING HAS BEEN AFFECTED BY THE BIM
COORDINATION PROCESS. PLEASE REFER TO THE
BIM COORDINATED SHOP DRAWINGS FOR DETAILS.
RFI 5554: Mount per specs. Bottom of fixture to be 6" above door frame, centered on door. Photocell to match height and be centered in MP-1 panel.