390-8EP105-P.pdf

PDF 436 KB Posted

Attached to
Z2DA--CFM - Rebalance HVAC System
Solicitation number
Not on record
Issued by

About this file

This document package includes an electrical power plan drawing and related federal contract solicitation. The power plan drawing depicts circuit layout and equipment locations for the fifth floor penthouse of Building 8EP105 and includes notes on scope items such as panel schedules, motor control diagrams, and general power requirements.

The related federal solicitation from the Department of Veterans Affairs Veterans Health Administration seeks bids to rebalance the HVAC system at their facility as outlined in the original solicitation and ninety-one attachments. Relevant details include work involving adjustment and calibration of the heating, ventilation, and air conditioning system controls and equipment to ensure proper airflow and thermal comfort as specified. The response due date and award timing are not provided.

View the file

Other files

File Type Posted
VAV DNT 02305-2MH630.pdf PDF
ICRA ILSM for CFM - Rebalance HVAC System.xlsx XLSX spreadsheet
CEP L01.pdf PDF
AMS Research 340-8MH601.pdf PDF
RESEARCH 3 5 mech plan.pdf PDF
P15-M-2 DNT Building Existing AHU sequence.pdf PDF
03503-6EP103-M3.pdf PDF
VAV Research 351-8MH612.pdf PDF
P14-M-4 OP Building Existing AHU sequence.pdf PDF
PANAM 104.pdf PDF
RESEARCH 5 dixie penthouse.pdf PDF
010000 General Requirements.pdf PDF
P07-General Decision.pdf PDF
S02-XHIBIT B PAST AND PRESENT PERFORMANCE QUESTIONNAIRE v2.pdf PDF
VAV DNT 02304-2MH629.pdf PDF
AMS OP 03027-3MH604.pdf PDF
P15-M-1 Typical Existing Service Bay layout.pdf PDF
OUT L07.pdf PDF
S02-EXHIBIT D CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY v2.pdf PDF
INP L03.pdf PDF
OUT L08.pdf PDF
S02-EXHIBIT A PERFORMANCE RELEVANCY SURVEY v2.pdf PDF
VAV Research 352-8MH613.pdf PDF
OUT L04.pdf PDF
OUT L05.pdf PDF
03491-6EL103-M3.pdf PDF
PANAM 105.pdf PDF
230593 Testing Adjusting and Balancing for HVAC.pdf PDF
230511 Common Work Results for HVAC.pdf PDF
M-3 DNT Building Existing DOAS sequence.pdf PDF
P12-ROOMS NUMBERS LIST WITH OLD AND NEW ROOM NUMBERS.xlsx XLSX spreadsheet
RESEARCH 2nd mech plan.pdf PDF
VAV DNT 02306-2MH631.pdf PDF
DNT L02i F-G.pdf PDF
RESEARCH 4th mech plan.pdf PDF
AMS TLR 03470-6MH604.pdf PDF
P12-000110 Table of Contents 4-7-20.pdf PDF
013526 Safety Requirements.pdf PDF
VAV DNT 02303-2MH628.pdf PDF
DNT L05 G.pdf PDF
S02-EXHIBIT E SURETY FORM.pdf PDF
AMS Research 348-8MH609.pdf PDF
CEP L03.pdf PDF
VAV DNT 02302-2MH627.pdf PDF
P12-230923 DDC Control System for HVAC 4-7-20.pdf PDF
DNT L01i D-E.pdf PDF
PANAM 103.pdf PDF
CEP L04.pdf PDF
VAV DNT 02301-2MH626.pdf PDF
230800 Commissioning of HVAC Systems.pdf PDF
Show 40 more

Latest 50 of 79 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

DN UP

DN

DN

DN

DN

UP

J JJ J J J

J

J

J

J

J

J

J

J

J

J

J

J

J

5 5

3/4

2 2 10 10

1 1/2

1/2

1/2

1/2

1/2

1/2

1/2

25 25

10 10 7.5 7.5

3/43/4

1/2

1/2

1/2

1/3

1/2

1/2

1/2

1/21/2

1/21/2

1/21/2

1/21/2

1/31/3

1/21/2 1/31/3

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/2

1/3

1/2

1/2

1/23/4

3/41/2

1 1

USS08

1000KVA XFMRMBFFTFFMB F

EMER

ELEC

5P101

ELEC

SW

GEAR

5P100

MECH

PENT

5P102

VEST

5P200

ELEV

PS-01

E U

S S

15KV

750KVA XFMR

MB

F

F

ELSD8451

ATS-EQ8-1

EQD8451

T5 D8451

08 1

08 2

08 3

08 7

08 9

08 4

8EP402

1000KVA XFMR15KV15KV

R8251B

ATS-ELS8-1

8EP404

8EP406

15KV

8ES505

8ES505

PULL BOX

PULL BOX

PROVIDE ACCESS PANEL

ON THIS SIDE OF

MASONARY ENCLOSURE

PROVIDE ACCESS PANEL

ON THIS SIDE OF

MASONARY ENCLOSURE

08 D 08 C 08 B 08 A08 E08 F08 G08 H08 I

FATCL845

ELSR825

T3

T5-1

D8452

WP

R8251A-

R8251A-3

T3

EQR8251

REX

ELSR825-1 1

E

REXELSR825-3

E

MECHANICAL

5P-CO47

TOWER

ACCESS

5P-CO49

UNOCCUPIED

5P-CO46

KT6 EQD8251

J.3

3.6

7.6

8.3

3.5

B.6

2.5

LTG

PWR

LTG

PWR

LTG

PWR

LTG

PWR

08-SF-2

08-SF-1

08-5P EF-16a

08-5P EF-16b

08-5P

RF-5

08-5P

SF-5

08-5P

SF-3

08-5P

EF-3

08-5P-AHU-2

08-5P-AHU-1

08-5P

EF-13

08-5P

EF-17

08-5P

EF-8

08-5P EF-15a

08-5P EF-15b

08-5P-AHU-5 08-5P-AHU-3 08-5P

EF-11a

08-5P EF-11b

08-5P

HWP-4

08-5P

HWP-3

08-5P

HWP-2

08-5P

HWP-1

08-5P

CP-1

08-5P

EF-4

08-5P

SF-4

08-5P

SF-6

08-5P

RF-6

08-5P-AHU-4 08-5P-AHU-6

08-5P

EF-19

08-5P

EF-9

08-5P

EF-10

08-5P

EF-7

08-5P

EF-6

08-5P

EF-5

08-5P

EF-18

08-5P EF-12a

08-5P EF-12b

08-5P

EF-2

08-5P

EF-1

08-5P

SF-7

08-5P

RF-7

08-5P-AHU-7

WPWP

EQ8451A-1

(20A-3P)

EQ8451A-7

(20A-3P)

EQ8451A-19

(20A-3P)

EQ8451A-25

(20A-3P)

EQ8451A-31

(20A-3P)

EQ8451A-26

(20A-3P)

EQ8451A-8

(20A-3P)

EQ8451A-14

(20A-3P)

EQ8451A-13

(20A-3P)

VFD-1 VFD-2 VFD-12 VFD-5 VFD-3 VFD-10

VFD-17

VFD-18

CP

EQD8452-5

(20A-3P)

EQD8452-4

(20A-3P)

D8451-6 (225A-3P)

D8451-3 (225A-3P)

D8451-4 (150A-3P)

D8451-10 (100A-3P)

EQD8452-3

(150A-3P)

EQD8452-2

(150A-3P)

VFD-9 VFD-8 1

VFD-14

VFD-7

VFD-16 VFD-15

D8451-9 (20A-3P)

D8451-7 (20A-3P)

EQ8451A-20

(20A-3P)

D8451-5 (100A-3P)

D8452-1 (225A-3P)

D8452-2 (150A-3P)

D8452-3 (20A-3P)

D8452-4 (20A-3P)

D8452-8 125A-3P)

D8452-7 (20A-3P)

VFD-13

VFD-6

VFD-11

VFD-4

S1 S2 S3 S4 S5 S6 S7 S8

S9

S10

S11

S12

S13

S14

R8251A-11

R8251A-13

R8251A-

WP

EQ8451A-32

(20A-3P)

EQD8452-7

(125A-3P)

EQD8452-6

(125A-3P)

EQD8452-11

(20A-3P) EQD8452-10

(20A-3P)

EQD8451-8

(50A-3P)

LAB AIR COMPRESSOR

LAB VACUUM PUMP

CP

EQ8451B-9

(70A-3P) 3#4&1#8G-1"C

CP

EQ8451B-3

(20A-3P) 3#12&1#12G-3/4"C

ATS-EL8-1

EQ8451A

EQ8451B

EQD8452

ELD8451

EQR8251-6

EQR8251-8

EQR8251-10

EQR8251-12

EQR8251-14

EQR8251-16

EQR8251-18

EQR8251-20

8ET-18ET-1

EQ8451A-37EQ8451A-39

D.2

1.5

E.5

8.5

K

L

M

N

WP12

08-5P

FCU-8

08-5P

FCU-10

08-5P

FCU-11

08-5P

FCU-12

08-5P

FCU-6

08-5P

FCU-7

08-5P

FCU-3

08-5P

FCU-4

08-5P

FCU-5

08-5P

FCU-1

08-5P

FCU-2

08-5P

FCU-9

08-5P

FCU-16

08-5P

FCU-15

08-5P

FCU-14

08-5P

FCU-13

R8251A

R8251B-1 (20A-2P)

R8251B-2 (20A-2P)

R8251B-5 (20A-2P)

R8251B-6 (20A-2P)

R8251B-9 (20A-2P)

R8251B-10 (20A-2P)

R8251B-13 (20A-2P)

R8251B-17 (20A-2P)

R8251B-14 (20A-2P)

R8251B-18 (20A-2P)

R8251B-21 (20A-2P)

R8251B-22 (20A-2P)

R8251B-25 (20A-2P)

R8251B-26 (20A-2P)

R8251B-29 (20A-2P)

R8251B-30 (20A-2P)

VFD-20

EQD8451-9

(50A-3P)

VFD-19

08-5P

HWP-8

08-5P

HWP-6

08-5P

HWP-5

08-5P

HWP-7

S17

EQ8451B-2

(20A-3P)

EQ8451A-14

(20A-3P)

EQ8451A-8

(20A-3P)

S16 S18 S19

EQ8451B-13

(20A-3P)

S20 S21

EQ8451B-19

(20A-3P)

HRW-2

HRW-1

D8452-6 (20A-3P)

EQ8451B-26

(80A-3P)

EQ8451B-20

(80A-3P)

D8452-9 (20A-3P)

Y3

EQR8251-11,13

(50A-2P)

COMPRESSOR

(FRZ RM 4P305)

COMPRESSOR

(FRZ RM 3P149A)

EQR8251-15,17,19

(20A-3P)

FUSED DISCONNECT(S) SHALL BE

PROVIDED TO MEET MANUFACTURERS

REQUIREMENTS

GENERAL POWER NOTES:

ELECTRICAL CONTRACTOR SHALL VERIFY EXACT PLUG

CONFIGURATION WITH EQUIPMENT MANUFACTURER

PRIOR TO INSTALLATION.

11.

REFER TO LEGEND AND GENERAL NOTES ON DRAWING 0ES001.1.

EXACT LOCATIONS OF FLOOR OUTLETS AND /POKE THRU DEVICES

SHALL BE COORDINATED WITH ARCHITECRAL FURNITURE PLANS

AND ACTUAL FIELD DIMENSIONS BASED ON DIRECTION FROM RESIDENT

ENGINEER.

2.

COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITH

MECHANICAL DRAWINGS.

3.

REFER TO MOTOR WIRING SCHEDULE ON DRAWING 8ES503 FOR MOTOR

FEEDER SIZES.

4.

VFD'S FURNISHED AND INSTALLED UNDER DIVISION 23 WIRED

UNDER DIVISION 26. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF VFD'S

5.

REFER TO MEDICAL EQUIPMENT FLOOR PLANS FOR EQUIPMENT LOCATIONS.6.

REFER TO ARCHITECTURAL ELEVATIONS FOR COORDINATION OF WALL

MOUNTED DEVICES AND MOUNTING HEIGHTS, PRIOR TO ROUGHIN.

7.

REFER TO A/V CONSULTANT DRAWINGS FOR A/V DEVICES AND REQUIRMENTS.8.

ALL BRANCH CIRCUIT WIRING FROM PANELS SHALL BE RUN ABOVE CEILINGS

IN AN ORGANIZED MANNER TO NETWORK JUNCTION BOXES. REFER TO

TYPICAL BRANCH CIRCUIT DETAIL DWG 8ES507.

9.

ALL PANEL BOARDS SHALL BE MOUNTED ON UNISTRUT SUPPORT

SYSTEM PER DETAIL ON DWG 8ES507.

12.

PROVIDE #10 AWG CONDUCTORS THROUGHOUT ALL BRANCH CIRCUIT WIRING AND

HOMERUN TO PANELBOARD.

10.

REFER TO DWG 8ES706 FOR MOTOR STARTER SCHEDULE AND DISCONNECT SWITCH

SCHEDULE.

13.

CARRY COST OF POWER CONNECTION AS AN ADD ALTERNATE.

KEY NOTES:

COORDINATE LOCATION OF DISCONNECT SWITCHES WITH UNIT.2

RUN BRANCH CIRCUIT FROM PANEL IN ACCESSABLE CEILING SPACE

BELOW TO DEVICES AND EQUIPMENT SERVING THIS SPACE.

Q D2 D1

E2 E1

F2 F1

G2 G1

A2

A4

A5

A1

A6

B1

C1 C2

B2

H

J1 J2

L

K

M1 M2 M3

P

N1 N2

A7

D3

E3

F3

R1

R4

R2 R3

A3

PLAN

NORTH

DATE

LOCATION

CHECKED DRAWN

PROJECT TITLE PROJECT NUMBER

DOCUMENT SET PACKAGE

DRAWING NUMBERAPPROVED: PROJECT DIRECTOR

DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:

REVISIONS: DATE

B

A

D

C

E

VA FORM 08-6231

O N

E

EI

G H

T

IN

C H

O

N E

FO

O

T O

N E

Q U

AR

TE

R

IN

C H

O

N E

FO

O

T O

N E

H A L

F

IN

C H

O

N E

FO

O

T

TH

R

EE

Q U

AR

TE

R S

IN

C

H

O N

E

FO

O T

TH

R

EE

IN

C H

ES

O N

E

FO

O T

O N

E

IN

C H

F

O R

TY

F

E E T

(1

0'

6"

6"

0'

0'

123456

F

B

A

D

C

E

F

O N

E

SI

X T

EE

N

TH

IN

C

H

O N

E

FO

O T

O N

E

AN

D O

N E

H

AL

F

IN

C H

ES

O N

E

FO

O T

6"

BUILDING NUMBER

8EP105-P

BLDG 8 FIFTH FLOOR PENTHOUSE POWER

PLAN-AREA P

SMAC ADSJuly 16, 2012

8629-HS2-401SLVHCS REPLACEMENT MEDICAL

CENTER PROJECT

NEW ORLEANS, LOUISIANA

SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL

KORDA/NEMETH ENGINEERING / STRUCTURAL

BR+A CONSULTANT ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE

ARCHITECTURAL ENGINEERING / PLUMBING

SCALES ASSOCIATES / FIRE PROTECTION

BR+A CONSULTING ENGINEERS / LOW VOLTAGE

DESMAN ASSOCIATES / PARKING

CODE CONSULTANTS, INC / CODE CONSULTANT

THE SEXTANT GROUP / AV & ACOUSTICAL

HAMMER DESIGN ASSOCIATES / FOOD SERVICE

PYBURN & ODOM / ABATEMENT

TATA & HOWARD / TANK CONSULTANT

Department of

Veterans Affairs

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

WP_09B

CONSTRUCTION DOCUMENTS 1

FULLY SPRINKLERED

1/8" = 1'-0"

B8-Level 05 - POWER

1 Revision 1 Date 1

8 Bulletin 046 10/12/2015

RFI:08614 - VFD-3 and VFD-10 will be relocated further east to have line of sight to units.

RFI:08640 VFD 19 and 20 relocated to area in front of HWP-1 and HWP-2

RFI:08642 - Circuits should be labeled 8-P-1 and 8-P-2 for the Domestic Water Pumps.

RFI:07544 - Added 120V/1 PH circuit from R8251 to feed tempered water recirc pumps.

RFI:8655 - (2) Added 120V/1 PH circuits from EQR8251 for 8NPWH-1&2 and 8DWH-1&2.

RFI:08679 - Due to lack of available space and in order to keep walkways clear it is acceptable to mount BAS, Fire Alarm, and Power conduit on the same unistrut rack.

RFI:08583 - Added Mechanical Equipment Control Transformer Power

- L5 = 14 Circuits.

RFI:08682.1 - Exhaust Fan Disconnect Requirements - Starter/Disconnect Combos Only if within sight.

RFI:08682.1 - Exhaust Fan Disconnect Requirements - Starter/Disconnect Combos Only if within sight.

..\..\RFIs\RFI 08001-09000\RFI 08614.pdf ..\..\RFIs\RFI 08001-09000\RFI 08640.pdf ..\..\RFIs\RFI 08001-09000\RFI 08642.pdf ..\..\RFIs\RFI 07001-08000\RFI 07544.pdf ..\..\RFIs\RFI 08001-09000\RFI 08655.pdf ..\..\RFIs\RFI 08001-09000\RFI 08679.pdf ..\..\RFIs\RFI 08001-09000\RFI 08583.pdf X:\Southern-East\113040 VANO CLIN 2 Construction\4_Contract Documents\RFIs\RFI 08001-09000\RFI 08682.1.pdf X:\Southern-East\113040 VANO CLIN 2 Construction\4_Contract Documents\RFIs\RFI 08001-09000\RFI 08682.1.pdf

File details come from the government source that posted it. Updated .