Attachment R - NAVFAC Dwg. Nos. 14089343 and 14089345.pdf
PDF 257 KB Posted
- Attached to
- P131 Communications Center - Souda Bay
- Solicitation number
- N62470-21-R-0005
About this file
This solicitation is for the design and construction of P131 Communications Center in Souda Bay, Greece. The Navy will award a firm fixed price contract to construct a multi-story communications facility for Naval Computer and Telecommunications Area Master Station Atlantic Detachment and Base N6 Communications Department at Naval Support Activity Souda Bay. The new facility will include a telephone exchange, electronics maintenance shops, storage for electronics spares and equipment, and will be a three-story cast-in-place concrete structure. Electrical utilities will include primary and secondary distribution systems, transformers, substation upgrades, telecommunications infrastructure, security systems infrastructure and lighting. The performance period is approximately 900 days after notice to proceed. The solicitation was issued by the Naval Facilities Engineering Command on behalf of the Department of the Navy.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N A
V S
U P
P A
C T
S O
U D
A B
A Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A
FIRE PROTECTION
N O
R F
O L
K
V A
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
P L O
T D
A T
E /T
IM
E
/2
/2
:4
:4 A
M C
U s e rs
\C h a n H
\D o c u m e n ts
\P -D
-M
R h o ili k .c h a n P
G
B .r v t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
M-811
GSH HC KG
P C
O M
M U
N
IC
A T
IO
N C
E N
T E
RS
O
U D
A B
A Y
G
R E
E C
E
C H
IL
L E
D W
A T
E R
S Y
S T
E M
S
E Q
U E
N C
E O
F O
P E
R A
T
IO
N S
14089343
Σ Υ
Σ Τ
Η Μ
Α Ν
Ε Ρ
Ο Υ
Ψ Υ
Ξ Η
Σ -Α
Κ Ο
Λ Ο
Υ Θ
ΙΑ
Λ
Ε
ΙΤ
Ο Υ
Ρ Γ
ΙΑ
Σ
SCE
DPS
CHILLER ISOLATION CONTROL VALVES
CHILLER ISOLATION CONTROL VALVES (CV-70 THROUGH CV-76) ARE PROVIDED TO ALLOW FOR EITHER CHILLER TO OPERATE WITH ANY PUMP/HEADER COMBINATION. CONTROLS CONTRACTOR TO CREATE A SET OF SEQUENCES THAT WILL COMMAND VALVES OPEN AND CLOSED AS NEEDED TO ALLOW FLOW TO ANY
COMBINATION OF OPERATING PUMP, OPERATING CHILLER, AND OPERATING HEADER.
SHUTDOWN:
WHEN THE SYSTEM IS COMMANDED TO SHUT DOWN, THE EQUIPMENT MUST BE ALIGNED AS FOLLOWS:
CHILLER - DISABLED, CHILLED WATER PUMPS - OFF, MINIMUM FLOW BYPASS - OPEN. CHILLER ISOLATION
VALVES CLOSED.
CHILLER MANAGER - LEAD/STANDBY OPERATION:
THE TWO CHILLER TRAINS, (EACH CHILLER AND ITS ASSOCIATED SUPPORT EQUIPMENT), MUST OPERATE IN A LEAD/STANDBY FASHION. CHILLER TRAIN MUST BE REFERRED TO AS CHILLER IN THIS SEQUENCE.THE FOLLOWING SETPOINTS ARE RECOMMENDED VALUES. ALL SETPOINTS MUST BE FIELD ADJUSTED DURING THE COMMISSIONING PERIOD TO MEET THE REQUIREMENTS OF THE ACTUAL FIELD CONDITIONS.
TO PREVENT SHORT CYCLING, THERE MUST BE A USER DEFINABLE DELAY (ADJUSTABLE) BETWEEN STAGING UP OR DOWN, UNLESS SHUTDOWN ON SAFETIES OR FAILURE. EACH CHILLER MUST RUN SUBJECT TO ITS
OWN INTERNAL SAFETIES AND CONTROLS.
• THE LEAD CHILLER SHALL RUN FIRST.
• ON FAILURE OF THE LEAD CHILLER, THE STANDBY CHILLER SHALL RUN AND THE LEAD CHILLER MUST
TURN OFF.
ON CHILLER FAULT OR SYSTEM SWITCH TO STANDBY CHILLER, A COMBINATION OF CHILLER BYPASS VALVES (CV-70 THROUGH CV-77) MUST BE SWITCHED TO OPERATE STANDBY CHILLER. CONTRACTOR TO CREATE A SERIES OF SEQUENCES TO AUTOMATE THE SWITCHOVER THROUGH THESE VALVES FOR A CHILLER FAULT.
THE DESIGNATED LEAD CHILLER AND CORRESPONDING LEAD PUMP MUST ROTATE UPON ONE OF THE
FOLLOWING CONDITIONS (USER SELECTABLE):
ON A CHILLER/PUMP ROTATION, SHUT DOWN LEAD CHILLER AND LEAD PUMP. ROTATE LEAD CHILLER AND LEAD PUMP. THEN START LEAD CHILLER AND LEAD PUMP. (INITIALLY ROTATE PUMPS AND CHILLERS ON A
WEEKLY BASIS DURING NIGHTTIME HOURS)
• MANUALLY THROUGH A SOFTWARE SWITCH
• IF CHILLER RUNTIME (ADJUSTABLE) IS EXCEEDED
• DAILY
• WEEKLY
• MONTHLY
ALARMS MUST BE PROVIDED AS FOLLOWS:
• HIGH MAIN CHILLER WATER SUPPLY TEMPERATURE: IF THE MAIN CHILLED WATER SUPPLY
TEMPERATURE IS GREAT THAN 13.3°C (ADJUSTABLE).
• LOW MAIN CHILLER WATER SUPPLY TEMPERATURE: IF THE MAIN CHILLED WATER SUPPLY
TEMPERATURE IS LESS THAN 3.3°C (ADJUSTABLE)
• HIGH MAIN CHILLER WATER RETURN TEMPERATURE: IF THE MAIN CHILLED WATER RETURN
TEMPERATURE IS GREAT THAN 20°C (ADJUSTABLE).
• LOW MAIN CHILLER WATER RETURN TEMPERATURE: IF THE MAIN CHILLED WATER RETURN
TEMPERATURE IS LESS THAN 8.3°C (ADJUSTABLE)
DUAL CHILLLED WATER DISTRIBUTION PATHS:
THERE IS ONE ACTIVE AND ONE ALTERNATE CHILLED WATER DISTRIBUTION PATH TO OPERATE IN A LEAD/STANDBY OPERATION. ON A DISTRIBUTION PATH WEEKLY CHANGEOVER, SHUT DOWN CHILLER, ROTATE DISTIBUTION PATH, THEN RESTART CHILLER. ON A FAILURE IN THE LEAD DISTRIBUTION PATH THE ALTERNATE DISTRIBUTION PATH SHALL OPEN AND THE LEAD PATH SHALL CLOSE. (INITIALLY ROTATE
DISTRIBUTION PATHS ON A WEEKLY BASIS DURING NIGHTTIME HOURS)
ALARMS MUST BE PROVIDED AS FOLLOWS:
• NO FLOW IN THE DISTRIBUTION PATH
• DISTRIBUTION PATH FAILURE. CONTROL VALVES COMMANDED OPEN BUT REMAIN CLOSED
CHILLED WATER SYSTEM - VARIABLE PRIMARY SEQUENCE OF OPERATION-
CONTINUED
BUILDING CHILLED WATER TEMPERATURE CONTROL:
THE BUILDING CHILLED WATER TEMPERATURE SETPOINT MUST BE MAINTAINED BY THE CHILLER'S OWN
INTERNAL CONTROLS.
THE FOLLOWING TEMPERATURES MUST BE MONITORED:
1. CHILLED WATER SUPPLY (T-01, T-02).
2. CHILLED WATER RETURN (T-03, T-04).
ALARMS MUST BE PROVIDED AS FOLLOWS:
1. BUILDING HIGH CHILLED WATER SUPPLY TEMP: IF GREATER THAN 8.0°C (ADJUSTABLE).
2. BUILDING LOW CHILLED WATER SUPPLY TEMP: IF LESS THAN 4.0°C (ADJUSTABLE).
CHILLER FREEZE PROTECTION:
WHEN THE OUTSIDE AIR TEMPERATURE IS BELOW 4.0°C (ADJUSTABLE), THE CHILLER'S CONTROLLER MUST ENABLE THE EVAPORATOR BARREL FREEZE PROTECTION. WHEN THE OUTSIDE AIR TEMPERATURE IS BELOW 1.7°C THE CHILLER SHALL ENERGIZE THE PRIMARY PUMP. OPEN THE COOLING COIL CONTROL VALVE 30% (ADJUSTABLE) ON THE AHU-1, AND DOAS-01 AND MODULATE. THE MINIMUM FLOW BYPASS VALVE (CV-12 OR CV-13 DEPENDING ON LEAD HEADER SELECTION) MUST MODULATE OPEN TO MAINTAIN MIN. FLOW ON CHILLER.
ΕΛΕΓΧΟΣ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΤΟΥ ΝΕΡΟΥ ΨΥΞΗΣ ΤΟΥ ΚΤΙΡΙΟΥ:
ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΤΟΥ ΝΕΡΟΥ ΨΥΞΗΣ ΤΟΥ ΚΤΙΡΙΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΗΡΕΙΤΑΙ ΑΠΟ ΤΟΥΣ ΕΝΣΩΜΑΤΩΜΕΝΟΥΣ
ΕΛΕΓΧΟΥΣ ΤΟΥ ΨΥΚΤΗ.
ΟΙ ΠΑΡΑΚΑΤΩ ΘΕΡΜΟΚΡΑΣΙΕΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΟΥΝΤΑΙ:
1. ΠΡΟΣΑΓΩΓΗ ΚΡΥΟΥ ΝΕΡΟΥ (T-01, T-02).
2. ΕΠΙΣΤΡΟΦΗ ΚΡΥΟΥ ΝΕΡΟΥ (T-03, T-04).
ΣΗΜΑΤΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΩΣ ΑΚΟΛΟΥΘΩΣ:
1. ΥΨΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΨΥΞΗΣ ΤΟΥ ΚΤΙΡΙΟΥ: ΟΤΑΝ ΕΙΝΑΙ ΜΕΓΑΛΥΤΕΡΗ ΤΩΝ 8.0οC (ΡΥΘΜΙΖΟΜΕΝΟ).
2. ΧΑΜΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΨΥΞΗΣ ΤΟΥ ΚΤΙΡΙΟΥ: ΟΤΑΝ ΕΙΝΑΙ ΜΙΚΡΟΤΕΡΗ ΤΩΝ 4.0οC (ΡΥΘΜΙΖΟΜΕΝΟ).
ΑΝΤΙΠΑΓΩΤΙΚΗ ΠΡΟΣΤΑΣΙΑ ΤΟΥ ΨΥΚΤΗ:
ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΕΞΩΤΕΡΙΚΟΥ ΑΕΡΑ ΕΙΝΑΙ ΚΑΤΩ ΤΩΝ 4.0oC (ΡΥΘΜΙΖΟΜΕΝΟ), Ο ΕΛΕΓΚΤΗΣ ΤΟΥ ΨΥΚΤΗ ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙ ΤΗΝ ΑΝΤΙΠΑΓΩΤΙΚΗ ΠΡΟΣΤΑΣΙΑ ΤΟΥ ΔΟΧΕΙΟΥ ΤΟΥ ΕΞΑΤΜΙΣΤΗ. ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΕΞΩΤΕΡΙΚΟΥ ΑΕΡΑ ΕΙΝΑΙ ΜΙΚΡΟΤΕΡΗ ΑΠΟ 1.7oC Ο ΨΥΚΤΗΣ ΠΡΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙ ΤΗΝ ΑΝΤΛΙΑ ΤΟΥ ΠΡΩΤΕΥΟΝΤΟΣ. ΑΝΟΙΞΤΕ ΤΗΝ ΒΑΛΒΙΔΑ ΕΛΕΓΧΟΥ ΤΟΥ ΨΥΚΤΙΚΟΥ ΣΤΟΙΧΕΙΟΥ 30% (ΡΥΘΜΙΖΟΜΕΝΟ) ΣΤΗΝ AHU-1, ΚΑΙ ΤΗΝ DOAS-01 KAI ΡΥΘΜΙΣΤΕ. Η ΒΑΛΒΙΔΑ ΤΗΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΠΑΡΑΚΑΜΨΗΣ (CV-12 ή CV-13 ΑΝΑΛΟΓΑ ΤΗΝ ΕΠΙΛΟΓΗ ΤΟΥ ΚΥΡΙΟΥ ΚΛΑΔΟΥ) ΠΡΕΠΕΙ ΝΑ ΡΥΘΜΙΣΤΕΙ ΑΝΟΙΚΤΗ ΓΙΑ ΤΗΝ ΔΙΑΤΗΡΗΣΗ ΤΗΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΣΤΟΝ ΨΥΚΤΗ.
ΒΑΛΒΙΔΕΣ ΕΛΕΓΧΟΥ ΑΠΟΜΟΝΩΣΗΣ ΤΟΥ ΨΥΚΤΗ:
ΟΙ ΒΑΛΒΙΔΕΣ ΕΛΕΓΧΟΥ ΑΠΟΜΟΝΩΣΗΣ ΤΟΥ ΨΥΚΤΗ (CV-70 ΕΩΣ CV-76) ΠΑΡΕΧΟΝΤΑΙ ΓΙΑ ΝΑ ΕΠΙΤΡΕΨΟΥΝ ΣΤΟΝ ΚΑΘΕ ΨΥΚΤΗ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΜΕ ΚΑΘΕ ΣΥΝΔΥΑΣΜΟ ΑΝΤΛΙΩΝ/ΚΛΑΔΩΝ. Ο ΕΡΓΟΛΑΒΟΣ ΤΩΝ ΕΛΕΓΚΤΩΝ ΝΑ ΔΗΜΙΟΥΡΓΗΣΕΙ ΕΝΑ ΣΥΛΟΛΟ ΑΠΟ ΑΚΟΛΟΥΘΙΕΣ ΠΟΥ ΘΑ ΕΝΤΕΛΛΟΥΝ ΤΙΣ ΒΑΛΒΙΔΕΣ ΑΝΟΙΚΤΕΣ ΚΑΙ ΚΛΕΙΣΤΕΣ ΩΣ ΑΠΑΙΤΕΙΤΑΙ ΩΣΤΕ ΝΑ ΕΠΙΤΡΕΠΕΤΑΙ Η ΡΟΗ ΠΡΟΣ ΚΑΘΕ ΣΥΝΔΥΑΣΜΟ ΑΠΟ ΑΝΤΛΙΑΣ ΣΕ
ΛΕΙΤΟΥΡΓΙΑ, ΨΥΚΤΗ ΣΕ ΛΕΙΤΟΥΡΓΙΑ, ΚΑΙ ΚΛΑΔΟ ΣΕ ΛΕΙΤΟΥΡΓΙΑ.
ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ:
ΟΤΑΝ ΤΟ ΣΥΣΤΗΜΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΑΠΕΝΕΡΓΟΠΟΙΗΘΕΙ, Ο ΕΞΟΠΛΙΣΜΟΣ ΠΡΕΠΕΙ ΝΑ ΕΥΘΥΓΡΑΜΜΙΖΕΤΑΙ ΩΣ ΑΚΟΛΟΥΘΩΣ: ΨΥΚΤΗΣ - ΑΠΕΝΕΡΓΟΠΟΙΗΜΕΝΟΣ, ΑΝΤΛΙΕΣ ΨΥΧΡΟΥ ΝΕΡΟΥ ΚΛΕΙΣΤΕΣ, ΠΑΡΑΚΑΜΨΗ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ - ΑΝΟΙΚΤΗ. ΒΑΛΒΙΔΕΣ ΑΠΟΜΟΝΩΣΗΣ ΨΥΚΤΗ
ΚΛΕΙΣΤΕΣ.
ΔΙΑΧΕΙΡΙΣΗ ΨΥΚΤΗ - ΛΕΙΤΟΥΡΓΙΑ ΚΥΡΙΟΣ/ΣΕ ΑΝΑΜΟΝΗ:
ΟΙ ΔΥΟ ΣΥΣΤΟΙΧΙΕΣ ΤΩΝ ΨΥΚΤΩΝ, (ΚΑΘΕ ΨΥΚΤΗΣ ΚΑΙ Ο ΑΝΤΙΣΤΟΙΧΟΣ ΥΠΟΣΤΗΡΙΚΤΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΤΟΥ), ΠΡΕΠΕΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΚΑΤΑ ΕΝΑ ΤΡΟΠΟ ΚΥΡΙΟΥ/ΣΕ ΑΝΑΜΟΝΗ. Η ΣΥΣΤΟΙΧΙΑ ΤΟΥ ΨΥΚΤΗ ΠΡΕΠΕΙ ΝΑ ΑΝΑΦΕΡΕΤΑΙ ΩΣ ΨΥΚΤΗΣ ΣΕ ΑΥΤΗ ΤΗΝ ΑΚΟΛΟΥΘΙΑ. ΤΑ ΠΡΟΚΑΘΟΡΙΣΜΕΝΑ ΣΗΜΕΙΑ ΠΟΥ ΑΚΟΛΟΥΘΟΥΝ ΕΙΝΑΙ ΠΡΟΤΕΙΝΟΜΕΝΕΣ ΤΙΜΕΣ. ΟΛΑ ΤΑ ΠΡΟΚΑΘΟΡΙΣΜΕΝΑ ΣΗΜΕΙΑ ΠΡΕΠΕΙ ΝΑ ΡΥΘΜΙΣΤΟΥΝ ΕΠΙ ΤΟΥ ΠΕΔΙΟΥ ΕΦΑΡΜΟΓΗΣ ΚΑΤΑ ΤΗΝ ΠΕΡΙΟΔΟ ΤΗΣ ΠΑΡΑΛΑΒΗΣ ΕΤΣΙ ΩΣΤΕ ΝΑ ΙΚΑΝΟΠΟΙΗΣΟΥΝ ΤΙΣ ΑΠΑΙΤΗΣΕΙΣ ΤΩΝ ΠΡΑΓΜΑΤΙΚΩΝ ΣΥΝΘΗΚΩΝ ΤΟΥ
ΠΕΔΙΟΥ.
ΓΙΑ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΣΥΝΤΟΜΟ ΚΥΚΛΟ ΛΕΙΤΟΥΡΓΙΑΣ, ΠΡΕΠΕΙ ΝΑ ΥΠΑΡΧΕΙ ΜΙΑ ΚΑΘΥΣΤΕΡΗΣΗ ΠΟΥ ΘΑ ΟΡΙΖΕΤΑΙ ΑΠΟ ΤΟΝ ΧΡΗΣΤΗ (ΡΥΘΜΙΖΟΜΕΝΗ) ΜΕΤΑΞΥ ΤΗΣ ΕΚΚΙΝΗΣΗΣ Ή ΤΗΣ ΣΤΑΣΗΣ, ΕΚΤΟΣ ΚΑΙ ΕΑΝ ΥΠΑΡΧΕΙ ΔΙΑΚΟΠΗ ΛΕΙΤΟΥΡΓΙΑΣ ΛΟΓΩ ΣΥΝΘΗΚΩΝ ΑΣΦΑΛΕΙΑΣ Ή ΑΣΤΟΧΙΑ. ΚΑΘΕ ΨΥΚΤΗΣ ΠΡΕΠΕΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΑΥΤΟΝΟΜΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ ΔΙΚΟ ΤΟΥ ΕΝΣΩΜΑΤΩΜΕΝΟ ΕΛΕΓΚΤΗ ΚΑΙ ΤΙΣ ΑΣΦΑΛΕΙΕΣ ΤΟΥ.
• Ο ΚΥΡΙΟΣ ΨΥΚΤΗΣ ΘΑ ΕΚΚΙΝΕΙ ΠΡΩΤΟΣ
• ΣΕ ΠΕΡΙΠΤΩΣΗ ΑΣΤΟΧΙΑ ΤΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ, Ο ΕΝ ΑΝΑΜΟΝΗ ΨΥΚΤΗΣ ΠΡΕΠΕΙ ΝΑ ΛΕΙΤΟΥΡΓΗΣΕΙ ΚΑΙ Ο ΚΥΡΙΟΣ ΨΥΚΤΗΣ ΠΡΕΠΕΙ ΝΑ
ΚΛΕΙΣΕΙ.
ΚΑΤΑ ΤΗΝ ΑΣΤΟΧΙΑ ΤΟΥ ΨΥΚΤΗ ή ΤΗΝ ΑΛΛΑΓΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΤΟΝ ΕΝ ΑΝΑΜΟΝΗ ΨΥΚΤΗ, ΕΝΑΣ ΣΥΝΔΥΑΣΜΟΣ ΤΩΝ ΒΑΛΒΙΔΩΝ ΠΑΡΑΚΑΜΨΗΣ ΤΟΥ ΨΥΚΤΗ (CV-70 ΕΩΣ CV-77) ΠΡΕΠΕΙ ΝΑ ΑΛΛΑΞΟΥΝ ΓΙΑ ΤΗΝ ΛΕΙΤΟΥΡΓΙΑ ΤΟΥ ΕΝ ΑΝΑΜΟΝΗ ΨΥΚΤΗ. Ο ΕΡΓΟΛΑΒΟΣ ΝΑ ΔΗΜΙΟΥΡΓΙΣΕΙ ΜΙΑ ΣΕΙΡΑ ΑΠΟ ΑΚΟΛΟΥΘΙΕΣ ΠΟΥ ΘΑ ΑΛΛΑΞΕΙ ΑΥΤΟΜΑΤΑ ΑΥΤΕΣ ΤΙΣ ΒΑΛΒΙΔΕΣ ΚΑΤΑ ΤΗΝ ΑΣΤΟΧΙΑ ΤΟΥ ΨΥΚΤΗ.
Ο ΟΡΙΣΜΕΝΟΣ ΩΣ ΠΡΩΤΕΥΩΝ ΨΥΚΤΗΣ ΚΑΙ Η ΑΝΤΙΣΤΟΙΧΗ ΑΝΤΛΙΑ ΠΡΕΠΕΙ ΝΑ ΕΝΑΛΛΑΣΣΟΝΤΑΙ ΚΑΤΑ ΤΗΝ ΕΜΦΑΝΙΣΗ ΜΙΑΣ ΕΚ ΤΩΝ ΠΑΡΑΚΑΤΩ
ΣΥΝΘΗΚΩΝ (ΕΠΙΓΟΓΗ ΑΠΟ ΤΟΝ ΧΕΙΡΙΣΤΗ):
ΚΑΤΑ ΤΗΝ ΕΝΑΛΛΑΓΗ ΨΥΚΤΗ/ΑΝΤΛΙΑΣ, ΑΠΕΝΕΡΓΟΠΟΙΗΣΤΕ ΤΟΝ ΠΡΩΤΕΥΟΝΤΑ ΨΥΚΤΗ ΚΑΙ ΤΗΝ ΑΝΤΛΙΑ, ΕΝΑΛΛΑΞΤΕ ΤΟΝ ΨΥΚΤΗ ΚΑΙ ΤΗΝ ΑΝΤΛΙΑ, ΚΑΙ ΕΠΕΙΤΑ ΕΚΚΙΝΗΣΤΕ ΤΟΝ ΝΕΟ ΠΡΩΤΕΥΟΝΤΑ ΨΥΚΤΗ ΚΑΙ ΤΗΝ ΑΝΤΛΙΑ. (ΑΡΧΙΚΑ ΕΝΑΛΛΑΞΤΕ ΤΙΣ ΔΙΑΔΡΟΜΕΣ ΔΙΑΝΟΜΗΣ ΣΕ
ΕΒΔΟΜΑΔΙΑΙΑ ΒΑΣΗ ΚΑΤΑ ΤΗ ΔΙΑΡΚΕΙΑ ΝΥΧΤΕΡΙΝΩΝ ΩΡΩΝ)
• ΧΕΙΡΟΚΙΝΗΤΑ ΜΕΣΩ ΕΝΟΣ ΔΙΑΚΟΠΤΗ ΛΟΓΙΣΜΙΚΟΥ
• ΕΑΝ Ο ΧΡΟΝΟΣ ΛΕΙΤΟΥΡΓΙΑ ΤΟΥ ΨΥΚΤΗ (ΡΥΘΜΙΖΟΜΕΝΟ) ΕΧΕΙ ΥΠΕΡΒΕΙ
• ΚΑΘΗΜΕΡΙΝΑ
• ΕΒΔΟΜΑΔΙΑΙΑ
• ΜΗΝΙΑΙΑ
ΣΗΜΑΤΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΩΣ ΑΚΟΛΟΥΘΩΣ:
• ΥΨΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ: ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΤΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ ΕΙΝΑΙ
ΜΕΓΑΛΥΤΕΡΗ ΤΩΝ 13.3°C (ΡΥΘΜΙΖΟΜΕΝΟ).
• ΧΑΜΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ: ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΤΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ ΕΙΝΑΙ
ΜΙΚΡΟΤΕΡΗ ΤΩΝ 3.3°C (ΡΥΘΜΙΖΟΜΕΝΟ)
• ΥΨΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΕΠΙΣΤΡΟΦΗΣ ΝΕΡΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ: ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΕΠΙΣΤΡΟΦΗΣ ΝΕΡΟΥ ΤΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ ΕΙΝΑΙ
ΜΕΓΑΛΥΤΕΡΗ ΤΩΝ 20°C (ΡΥΘΜΙΖΟΜΕΝΟ).
• ΧΑΜΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΕΠΙΣΤΡΟΦΗΣ ΝΕΡΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ: ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΕΠΙΣΤΡΟΦΗΣ ΝΕΡΟΥ ΤΟΥ ΚΥΡΙΟΥ ΨΥΚΤΗ ΕΙΝΑΙ
ΜΙΚΡΟΤΕΡΗ ΤΩΝ 8.3°C (ΡΥΘΜΙΖΟΜΕΝΟ)
ΔΙΠΛΕΣ ΔΙΑΔΡΟΜΕΣ ΔΙΑΝΟΜΗΣ ΚΡΥΟΥ ΝΕΡΟΥ:
ΥΠΑΡΧΕΙ ΜΙΑ ΕΝΕΡΓΗ ΚΑΙ ΜΙΑ ΕΝΑΛΛΑΚΤΙΚΗ ΔΙΑΔΡΟΜΗ ΔΙΑΝΟΜΗΣ ΚΡΥΟΥ ΝΕΡΟΥ ΓΙΑ ΤΗΝ ΛΕΙΤΟΥΡΓΙΑ ΣΕ ΚΥΡΙΩΣ/ΣΕ ΑΝΑΜΟΝΗ ΛΕΙΤΟΥΡΓΙΑ.
ΚΑΤΑ ΤΗΝ ΕΒΔΟΜΑΔΙΑΙΑ ΑΛΛΑΓΗ ΤΗΣ ΔΙΑΔΡΟΜΗΣ ΔΙΑΝΟΜΗΣ, ΑΠΕΝΕΡΓΟΠΟΙΗΣΤΕ ΤΟΝ ΨΥΚΤΗ, ΕΝΑΛΛΑΞΤΕ ΤΙΣ ΔΙΑΔΡΟΜΕΣ ΚΑΙ ΕΠΕΙΤΑ ΕΠΑΝΕΚΚΙΝΗΣΤΕ ΤΟΝ ΨΥΚΤΗ. ΚΑΤΑ ΤΗΝ ΠΕΡΙΠΤΩΣΗ ΑΣΤΟΧΙΑΣ ΣΤΗΝ ΚΥΡΙΑ ΔΙΑΔΡΟΜΗ ΔΙΑΝΟΜΗΣ, Η ΕΝΑΛΛΑΚΤΙΚΗ ΔΙΑΔΡΟΜΗ ΔΙΑΝΟΜΗΣ ΘΑ ΑΝΟΙΞΕΙ ΚΑΙ Η ΚΥΡΙΑ ΔΙΑΔΡΟΜΗ ΘΑ ΚΛΕΙΣΕΙ.(ΑΡΧΙΚΑ ΕΝΑΛΛΑΞΤΕ ΤΙΣ ΔΙΑΔΡΟΜΕΣ ΔΙΑΝΟΜΗΣ ΣΕ ΕΒΔΟΜΑΔΙΑΙΑ ΒΑΣΗ ΚΑΤΑ ΤΗ ΔΙΑΡΚΕΙΑ
ΝΥΧΤΕΡΙΝΩΝ ΩΡΩΝ).
ΣΗΜΑΤΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΩΣ ΑΚΟΛΟΥΘΩΣ:
• ΑΠΟΥΣΙΑ ΡΟΗΣ ΣΤΗΝ ΔΙΑΔΡΟΜΗ ΔΙΑΝΟΜΗΣ.
• ΑΣΤΟΧΙΑ ΤΗΣ ΔΙΑΔΡΟΜΗΣ ΔΙΑΝΟΜΗΣ. ΟΙ ΒΑΛΒΙΔΕΣ ΕΛΕΓΧΟΥ ΕΝΤΕΛΛΟΝΤΑΙ ΑΝΟΙΚΤΕΣ ΑΛΛΑ ΠΑΡΑΜΕΝΟΥΝ ΚΛΕΙΣΤΕΣ.
ΣΥΣΤΗΜΑ ΚΡΥΟΥ ΝΕΡΟΥ - ΑΚΟΛΟΥΘΙΑ ΛΕΙΤΟΥΡΓΙΑΣ ΜΕΤΑΒΛΗΤΟΥ ΠΡΩΤΕΥΟΝΤΟΣ -
ΣΥΝΕΧΕΙΑ
A
M E
N D
M E
N T
-2
-2
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
N A
V S
U P
P A
C T
S O
U D
A B
A Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
C O
M M
A N
D
A
FIRE PROTECTION
N O
R F
O L
K
V A
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
P L O
T D
A T
E /T
IM
E
/2
/2
:4
:4 A
M C
U s e rs
\C h a n H
\D o c u m e n ts
\P -D
-M
R h o ili k .c h a n P
G
B .r v t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
M-813
GSH HC KG
P C
O M
M U
N
IC
A T
IO
N C
E N
T E
RS
O
U D
A B
A Y
G
R E
E C
E
H E
A T
IN
G
W A
T E
R S
Y S
T E
M
S E
Q U
E N
C E
O F
O P
E R
A T
IO
N
S
14089345
Σ Υ
Σ Τ
Η Μ
Α Ν
Ε Ρ
Ο Υ
Θ Ε
Ρ Μ
Α Ν
Σ Η
Σ
Α Κ
Ο Λ
Ο Υ
Θ
ΙΑ
Λ Ε
ΙΤ
Ο
Υ Ρ
Γ
ΙΑ
Σ
SCE
DPS
SYSTEM CONFIGURATION:
THE HEATING WATER SYSTEM MUST PROVIDE HOT WATER TO THE HYDRONIC HEATING COILS. THE SYSTEM CONSISTS OF ONE AIR-COOLED
HEAT PUMP. THE SYSTEM EMPLOYS A VARIABLE PRIMARY PUMPING SYSTEM.
RUN CONDITIONS:
THE HEATING WATER SYSTEM MUST BE ENABLED TO RUN WHEN A MINIMUM OF THREE (ADJUSTABLE) TERMINAL UNITS OR ONE AIR HANDLING COIL HOT WATER CONTROLLERS CALL FOR HEATING AND THEIR RESPECTIVE CONTROL VALVES ARE GREATER THAN 20% (ADJUSTABLE) OPEN FOR GREATER THAN 3 MINUTES (ADJUSTABLE) OR INITIATION OF START SEQUENCE AT EITHER THE BAS WORKSTATION OR THE NETWORK CONTROLLER OR THE LOCAL CONTROL PANEL. BUILDING HEATING HOT WATER SYSTEM MUST BE DISABLED BY THE DDC SYSTEM WHENEVER DEACTIVATED BY DDC SYSTEM SCHEDULING, OR NO HOT WATER CONTROLLERS ARE CALLING FOR HEATING, OR MANUALLY COMMANDED BY THE OPERATOR. TO PREVENT SHORT CYCLING, THE BUILDING HEATING HOT WATER SYSTEM MUST RUN FOR AND BE OFF
FOR A MINIMUM TIME OF 30 MINUTES (ADJUSTABLE) UNLESS SHUT DOWN ON SAFETIES.
HEAT PUMP OPERATION:
WHEN THE HEATING WATER SYSTEM IS ENABLED TO OPERATE, THE HEAT PUMP SHALL BE COMMANDED TO START AND MUST ACTIVATE USING ITS OWN INTERNAL STARTUP CONTROL SEQUENCE. AS PART OF THE STARTUP SEQUENCE, FLOW THROUGH THE UNIT SHALL BE
VERIFIED (DETECTED AT THE FLOW SENSOR) TO BE ABOVE THE MINIMUM FLOW REQUIREMENT.
THE HEAT PUMP MUST RUN SUBJECT TO IT'S OWN INTERNAL SAFETIES AND CONTROLS. THE BAS MUST ENABLE/DISABLE THE HEAT PUMP AND MONITOR AVAILABLE CONTROL POINTS THROUGH A BAS INTERFACE CARD FURNISHED BY THE MANUFACTURER. WHEN THE HEATING WATER SYSTEM IS DISABLED, HEAT PUMP MUST BE COMMANDED TO STOP IN SEQUENCE AND MUST DEACTIVATE USING IT'S OWN INTERNAL
SHUTDOWN CONTROL SEQUENCE.
HEAT PUMP SAFETIES: THE FOLLOWING SAFETIES MUST BE MONITORED THROUGH THE BAS:
1. HEAT PUMP ALARM.
2. LOW HEAT PUMP EVAPORATOR FLOW.
ALARMS MUST BE PROVIDED TO THE BAS OPERATOR INTERFACE AS FOLLOWS:
1. HEAT PUMP LEAVING WATER TEMPERATURE 2°C LOWER THAN SETPOINT FOR 15 MINUTES.
2. HEAT PUMP ALARM.
3. NO FLOW SIGNAL (FS-HPCH-01).
4. LOW CONDENSER TEMPERATURE.
5. HIGH CONDENSER PRESSURE.
BUILDING HEATING WATER TEMPERATURE CONTROL:
THE BUILDING HEATING WATER TEMPERATURE SETPOINT MUST BE MAINTAINED BY THE HEAT PUMP'S OWN INTERNAL CONTROLS.
THE FOLLOWING TEMPERATURES MUST BE MONITORED:
1. HEATING WATER SUPPLY (T-01).
2. HEATING WATER RETURN (T-02).
ALARMS MUST BE PROVIDED AS FOLLOWS:
1. BUILDING HIGH HEATING WATER SUPPLY TEMP: IF GREATER THAN 62.8°C (ADJUSTABLE).
2. BUILDING LOW HEATING WATER SUPPLY TEMP: IF LESS THAN 32.2°C (ADJUSTABLE).
3. BUILDING HIGH HEATING WATER RETURN TEMP: IF EQUAL TO OR GREATER THAN (ADJUSTABLE) THE SUPPLY SETPOINT.
SUPPLY WATER TEMPERATURE RESET:
LEAVING WATER TEMPERATURE MUST BE RESET BASED ON OUTDOOR TEMPERATURE. LEAVING WATER TEMPERATURE SETPOINT MUST BE
LINEARLY DERIVED BETWEEN THE FOLLOWING LIMITS:
1. AT AN OUTSIDE TEMPERATURE OF 6°C (OR BELOW), LEAVING WATER TEMPERATURE SHALL BE 49.0°C.
2. AT AN OUTSIDE TEMPERATURE OF 13°C (OR ABOVE), LEAVING WATER TEMPERATURE SHALL BE 38.0°C.
BUILDING HEATING WATER SYSTEM - PUMP OPERATION:
TWO HEATING WATER PUMPS MUST BE PROVIDED (1 OPERATING AND 1 SPARE) WITH THE HEATING WATER SYSTEM. THE BAS OR OPERATOR MUST HAVE THE ABILITY TO DESIGNATE EITHER PUMP AS THE OPERATING (OR LEAD) AND THE OTHER AS SPARE (OR LAG). THE BAS/OPERATOR MUST HAVE THE CAPABILITY TO ROTATE THE SEQUENCE AUTOMATICALLY BASED ON THE FOLLOWING:
1. MANUALLY THROUGH A SOFTWARE SWITCH.
2. PUMP RUNTIME.
3. SCHEDULING, SUCH AS ROTATING THE SEQUENCE ONCE PER DAY, WEEK, MONTH, SEASON, ETC.
THE OPERATING PUMP MUST BE COMMANDED TO START PRIOR TO THE HEAT PUMP IS COMMANDED ON. WHEN THE HEAT PUMP IS DEACTIVATED, THE PUMPS MUST BE COMMANDED TO STOP AFTER A 5 MINUTE TIME DELAY (ADJUSATABLE). UPON FAILURE OF THE OPERATING PUMP THE SPARE PUMP MUST BE STARTED AND THE OPERATING PUMP MUST BE COMMANDED OFF. PUMP FAILURE MUST BE
DETERMINED USING THE PUMP FAILURE ALARM LIST.
WHEN A PUMP IS COMMANDED TO START IT MUST E ENERGIZED AT MINIMUM VFD SPEED THEN RAMP AS REQUIRED BY THE DIFFERENTIAL PRESSURE CONTROL SYSTEM AND TO MAINTAIN THE MINIMUM REQUIRED FLOW THROUGH THE HEAT PUMP. WHEN A PUMP IS COMMANDED TO STOP IT MUST FIRST CONTINUE TO RUN FOR A SUITABLE TIME DELAY PERIOD (INITIAL SETTING: 5 MINUTES, ADJUSTABLE), THEN SHALL
RAMP TO MINIMUM VFD SPEED THEN BE DEENERGIZED.
THE CONTROLLER MUST MONITOR THE SYSTEM DIFFERENTIAL PRESSURE SENSORS AND VARY THE PUMP'S VFD SPEED TO MAINTAIN THE DIFFERENTIAL PRESSURE SETPOINTS AT EACH SENSOR (INITIAL SETPOINTS OF 10 FT W.C. (ADJUSTABLE), FINAL SETPOINTS TO BE DETERMINED DURING TEST AND BALANCE). ON A DROP IN SYSTEM DIFFERENTIAL PRESSURE, THE PUMP SPEED MUST BE APPROPRIATELY INCREASED. ON A RISE IN SYSTEM DIFFERENTIAL PRESSURE, THE PUMP SPEED MUST BE APPROPRIATELY DECREASED WHILE STILL MAINTAINING THE MINIMUM FLOW THROUGH THE HEAT PUMP(COMBINED WITH THE USE OF THE MINIMUM FLOW BYPASS VALVE). THE
MINIMUM PUMP SPEED HZ WILL MATCH THE MINIMUM HEAT PUMP FLOW.
FAILURE ALARMS: FAILING PUMP TO BE COMMANDED OFF. AN ALARM MUST BE PROVIDED TO BAS AS FOLLOWS:
1. HEATING WATER PUMP FAILURE: COMMANDED ON, BUT THE STATUS IS OFF.
2. HEATING WATER PUMP RUNNING IN HAND: COMMANDED OFF, BUT THE STATUS IS ON.
3. HEATING WATER PUMP VFD FAILURE.
NON-FAILURE ALARM: PUMP MUST NOT BE COMMANDED OFF. ALARM SHALL BE SENT TO BAS AS FOLLOWS:
1. HEATING WATER PUMP RUNTIME EXCEEDED: STATUS RUNTIME EXCEEDS A USER DEFINABLE LIMIT.
MINIMUM FLOW BYPASS:
THE MINIMUM FLOW BYPASS CONTROL VALVE (FCV-01) MUST MODULATE OPEN UPON A DROP IN FLOW THROUGH THE FLOW SENSOR (FT-01) BELOW THE MINIMUM FLOW NEEDED TO MAINTAIN THE HEAT PUMP'S MINIMUM FLOW. THE MINIMUM FLOW BYPASS CONTROL VALVE (FCV-01) MUST REMAIN CLOSED WHEN THE DIFFERENTIAL FLOW IS ABOVE THE HEAT PUMP'S MINIMUM FLOW. THE DESIGN MINIMUM FLOW FOR THE HEAT PUMP IS TO BE VERIFIED WITH THE MANUFACTURER. PROVIDE A FAIL OPEN/SPRING OPEN MINIMUM FLOW BYPASS VALVE HARD WIRED
TO THE SAME DDC PANEL AS THE HEAT PUMP.
DIFFERENTIAL PRESSURE RESET (DP-01):
THE DIFFERENTIAL PRESSURE SETPOINT MUST BE RESET DOWN TO MAINTAIN A MAXIMUM OF 1 (ADJUSTABLE) CONTROL VALVE AT A MAXIMUM OF 90% (ADJUSTABLE) OPEN. AS MORE CONTROL VALVES OPEN THE DIFFERENTIAL PRESSURE SETPOINT SHALL RESET UP TO THE
SETPOINT PRESSURE ESTABLISHED DURING BALANCING.
HEATING WATER FREEZE PROTECTION:
WHEN THE OUTSIDE AIR TEMPERATURE IS BELOW 4.0°C (ADJUSTABLE), THE BAS MUST ACTIVATE THE HEATING WATER PUMP, AND OPEN THE
HEATING WATER VALVES ON THE AHU'S, AND DOAS TO A MINIMUM OF 20%.
HEATING WATER SYSTEM SEQUENCE OF OPERATION
ΔΙΑΜΟΡΦΩΣΗ ΣΥΣΤΗΜΑΤΟΣ:
ΤΟ ΣΥΣΤΗΜΑ ΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΕΙ ΖΕΣΤΟ ΝΕΡΟ ΣΤΑ ΥΔΡΑΥΛΙΚΑ ΣΤΟΙΧΕΙΑ ΘΕΡΜΑΝΣΗΣ. ΤΟ ΣΥΣΤΗΜΑ ΑΠΟΤΕΛΕΙΤΑΙ ΑΠΟ ΜΙΑ ΑΕΡΟΨΥΚΤΗ ΑΝΤΛΙΑ
ΘΕΡΜΟΤΗΤΑΣ. ΤΟ ΣΥΣΤΗΜΑ ΑΠΑΣΧΟΛΕΙ ΕΝΑ ΣΥΣΤΗΜΑ ΜΕΤΑΒΛΗΤΗΣ ΑΝΤΛΙΑΣ ΠΡΩΤΕΥΟΝΤΟΣ.
ΣΥΝΘΗΚΕΣ ΛΕΙΤΟΥΡΓΙΑΣ:
ΤΟ ΣΥΣΤΗΜΑ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΟΤΑΝ ΕΝΑ ΕΛΑΧΙΣΤΟ ΑΠΟ ΤΡΕΙΣ (ΡΥΘΜΙΖΟΜΕΝΟ) ΤΕΡΜΑΤΙΚΕΣ ΜΟΝΑΔΕΣ ή AΠΟ ΕΝΑ ΣΤΟΙΧΕΙΟ ΔΙΑΧΕΙΡΙΣΗΣ ΑΕΡΑ ΟΙ ΕΛΕΓΚΤΕΣ ΖΕΣΤΟΥ ΝΕΡΟΥ ΖΗΤΟΥΝ ΘΕΡΜΑΝΣΗ ΚΑΙ ΟΙ ΑΝΤΙΣΤΟΙΧΕΣ ΒΑΛΒΙΔΕΣ ΕΛΕΓΧΟΥ ΕΙΝΑΙ ΠΑΝΩ ΑΠΟ 20% (ΡΥΘΜΙΖΟΜΕΝΟ) ΑΝΟΙΚΤΕΣ ΓΙΑ ΠΕΡΙΣΣΟΤΕΡΟ ΑΠΟ 3 ΛΕΠΤΑ (ΡΥΘΜΙΖΟΜΕΝΟ) ή ΑΡΧΙΚΗ ΑΚΟΛΟΥΘΙΑ ΕΚΚΙΝΗΣΗΣ ΣΤΟ ΣΤΑΘΜΟ ΕΡΓΑΣΙΑΣ ΤΟΥ BAS, ή ΤΟΝ ΕΛΕΓΚΤΗ ΤΟΥ ΔΙΚΤΥΟΥ, ή ΤΟΥ ΤΟΠΙΚΟΥ ΠΙΝΑΚΑ ΕΛΕΓΧΟΥ. ΤΟ ΣΥΣΤΗΜΑ ΖΕΣΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ ΠΡΕΠΕΙ ΝΑ ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΑΠΟ ΤΟ ΣΥΣΤΗΜΑ DDC ΚΑΘΕ ΦΟΡΑ ΠΟΥ ΥΦΙΣΤΑΤΑΙ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΛΟΓΩ ΠΡΟΓΡΑΜΜΑΤΙΣΜΟΥ ΑΠΟ ΤΟ ΣΥΣΤΗΜΑ DDC, ή ΟΙ ΕΛΕΓΚΤΕΣ ΤΟΥ ΖΕΣΤΟΥ ΝΕΡΟΥ ΔΕΝ ΕΧΟΥΝ ΖΗΤΗΣΗ ΓΙΑ ΘΕΡΜΑΝΣΗ, ή ΟΤΑΝ ΕΝΤΕΛΛΕΤΑΙ ΧΕΙΡΟΚΙΝΗΤΑ ΑΠΟ ΤΟΝ ΧΕΙΡΙΣΤΗ. ΓΙΑ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΑΠΟ ΣΥΝΤΟΜΟ ΧΡΟΝΙΚΟ ΔΙΑΣΤΗΜΑ ΚΥΚΛΙΚΗΣ ΛΕΙΤΟΥΡΓΙΑΣ, ΤΟ ΣΥΣΤΗΜΑ ΖΕΣΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ ΠΡΕΠΕΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΚΑΙ ΝΑ ΕΙΝΑΙ ΕΚΤΟΣ ΛΕΙΤΟΥΡΓΙΑΣ ΓΙΑ ΕΝΑ ΕΛΑΧΙΣΤΟ ΧΡΟΝΙΚΟ ΔΙΑΣΤΗΜΑ 30 ΛΕΠΤΩΝ (ΡΥΘΜΙΖΟΜΕΝΟ) ΕΚΤΟΣ ΚΑΙ ΕΑΝ ΑΠΕΝΕΡΓΟΠΟΙΗΘΕΙ ΓΙΑ ΛΟΓΟΥΣ ΑΣΦΑΛΕΙΑΣ.
ΛΕΙΤΟΥΡΓΙΑ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ:
ΟΤΑΝ ΤΟ ΣΥΣΤΗΜΑ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΝΕΡΟΥ ΕΝΕΡΓΟΠΟΙΗΘΕΙ ΓΙΑ ΝΑ ΛΕΙΤΟΥΡΓΗΣΕΙ, Η ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΕΚΚΙΝΗΣΕΙ ΚΑΙ ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΗΘΕΙ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΤΗΝ ΔΙΚΗ ΤΗΣ ΕΝΣΩΜΑΤΩΜΕΝΗ ΑΚΟΛΟΥΘΙΑ ΕΚΚΙΝΗΣΗΣ. ΩΣ ΤΜΗΜΑ ΤΗΣ ΑΚΟΛΟΥΘΙΑΣ ΕΚΚΙΝΗΣΗΣ, Η ΡΟΗ ΜΕΣΑ ΣΤΗΝ ΜΟΝΑΔΑ ΠΡΕΠΕΙ ΝΑ ΕΠΙΒΕΒΑΙΩΘΕΙ (ΑΝΙΧΝΕΥΕΤΑΙ ΣΤΟΝ ΑΙΣΘΗΤΗΡΑ ΡΟΗΣ) ΟΤΙ ΕΙΝΑΙ ΜΕΓΑΛΥΤΕΡΗ ΑΠΟ ΤΗΝ ΕΛΑΧΙΣΤΗ ΑΠΑΙΤΟΥΜΕΝΗ ΡΟΗ.
Η ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΠΡΕΠΕΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΔΙΚΕΣ ΤΗΣ ΕΝΣΩΜΑΤΩΜΕΝΕΣ ΑΣΦΑΛΕΙΕΣ ΚΑΙ ΕΛΕΓΚΤΕΣ. ΤΟ BAS ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙ/ΑΠΕΝΕΡΓΟΠΟΙΕΙ ΤΗΝ ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΚΑΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΕΙ ΤΑ ΔΙΑΘΕΣΙΜΑ ΣΗΜΕΙΑ ΕΛΕΓΧΟΥ ΜΕΣΩ ΜΙΑΣ ΚΑΡΤΑΣ ΔΙΕΠΑΦΗΣ BAS ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ. ΟΤΑΝ ΤΟ ΣΥΣΤΗΜΑ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΝΕΡΟΥ ΕΙΝΑΙ ΑΠΕΝΕΡΓΟΠΟΙΗΜΕΝΟ, Η ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΣΤΑΜΑΤΑ ΜΕ ΑΚΟΛΟΥΘΙΑ ΚΑΙ ΠΡΕΠΕΙ ΝΑ ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΤΗΝ ΔΙΚΗ ΤΗΣ
ΕΝΣΩΜΑΤΩΜΕΝΗ ΑΚΟΛΟΥΘΙΑ ΕΛΕΓΧΟΥ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗΣ.
ΑΣΦΑΛΕΙΕΣ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ: ΟΙ ΑΚΟΛΟΥΘΕΣ ΑΣΦΑΛΕΙΕΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΟΥΝΤΑΙ ΜΕΣΩ ΤΟΥ BAS:
1. ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ
2. ΧΑΜΗΛΗ ΡΟΗ ΤΟΥ ΕΞΑΤΜΙΣΤΗ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ.
ΣΥΝΑΓΕΡΜΟΙ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΣΤΟΝ ΧΕΙΡΙΣΤΗ ΤΗΣ ΔΙΕΠΑΦΗΣ ΤΟΥ BAS ΩΣ ΑΚΟΛΟΥΘΩΣ:
1. Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΝΕΡΟΥ ΑΠΟ ΤΗΝ ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΝΑ ΠΑΡΑΜΕΝΕΙ ΓΙΑ 15' ΧΑΜΗΛΟΤΕΡΗ 2oC ΑΠΟ ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ.
2. ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ
3. ΑΠΟΥΣΙΑ ΣΗΜΑΤΟΣ ΡΟΗΣ (FS-HPCH-01).
4. ΧΑΜΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΣΥΜΠΥΚΝΩΣΗΣ.
5. ΥΨΗΛΗ ΠΙΕΣΗ ΣΥΜΠΥΚΝΩΤΗ.
ΕΛΕΓΧΟΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΚΤΙΡΙΟΥ:
ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΘΕΡΜΟΚΡΑΣΙΑΣ ΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΗΡΕΙΤΑΙ ΑΠΟ ΤΟΥΣ ΕΣΩΤΕΡΙΚΟΥΣ ΕΛΕΓΚΤΕΣ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ.
ΟΙ ΑΚΟΛΟΥΘΕΣ ΘΕΡΜΟΚΡΑΣΙΕΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΟΥΝΤΑΙ:
1. ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ (T-01).
2. ΕΠΙΣΤΡΟΦΩΝ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ (T-02).
ΣΗΜΑΤΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΩΣ ΑΚΟΛΟΥΘΩΣ:
1. ΥΨΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ: ΟΤΑΝ ΕΙΝΑΙ ΜΕΓΑΛΥΤΕΡΗ ΑΠΟ 62.8oC (ΡΥΘΜΙΖΟΜΕΝΟ).
2. ΧΑΜΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΠΡΟΣΑΓΩΓΗΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ: ΟΤΑΝ ΕΙΝΑΙ ΜΙΚΡΟΤΕΡΗ ΑΠΟ 32.2oC (ΡΥΘΜΙΖΟΜΕΝΟ).
3. ΥΨΗΛΗ ΘΕΡΜΟΚΡΑΣΙΑ ΕΠΙΣΤΡΟΦΗΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ: ΟΤΑΝ ΕΙΝΑΙ ΙΣΗ ή ΜΕΓΑΛΥΤΕΡΗ ΑΠΟ ΤΟ (ΡΥΘΜΙΖΟΜΕΝΟ) ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΤΗΣ ΠΡΟΣΑΓΩΓΗΣ.
ΕΠΑΝΑΠΡΟΣΔΙΟΡΙΣΜΟΣ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΤΟΥ ΝΕΡΟΥ ΠΡΟΣΑΓΩΓΗΣ:
Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΝΕΡΟΥ ΑΝΑΧΩΡΗΣΗΣ ΠΡΕΠΕΙ ΝΑ ΕΠΑΝΑΠΡΟΣΔΙΟΡΙΖΕΤΑΙ ΣΥΜΦΩΝΑ ΜΕ ΤΗΝ ΕΞΩΤΕΡΙΚΗ ΘΕΡΜΟΚΡΑΣΙΑ. ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΤΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ ΤΟΥ
ΝΕΡΟΥ ΑΝΑΧΩΡΗΣΗΣ ΠΡΕΠΕΙ ΝΑ ΜΕΤΑΒΑΛΛΕΤΑΙ ΓΡΑΜΜΙΚΑ ΜΕΤΑΞΥ ΤΩΝ ΑΚΟΛΟΥΘΩΝ ΟΡΙΩΝ:
1. ΟΤΑΝ Η ΕΞΩΤΕΡΙΚΗ ΘΕΡΜΟΚΡΑΣΙΑ ΕΙΝΑΙ 6oC (ή ΜΙΚΡΟΤΕΡΗ), Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΝΕΡΟΥ ΑΝΑΧΩΡΗΣΗΣ ΘΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ 49.0oC
2. ΟΤΑΝ Η ΕΞΩΤΕΡΙΚΗ ΘΕΡΜΟΚΡΑΣΙΑ ΕΙΝΑΙ 13oC (ή ΜΕΓΑΛΥΤΕΡΗ), Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΝΕΡΟΥ ΑΝΑΧΩΡΗΣΗΣ ΘΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ 38.0oC
ΛΕΙΤΟΥΡΓΙΑ ΤΗΣ ΑΝΤΛΙΑΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ:
ΔΥΟ ΑΝΤΛΙΕΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ (1 ΕΝ ΛΕΙΤΟΥΡΓΙΑ ΚΑΙ 1 ΕΦΕΔΡΙΚΗ) ΜΑΖΙ ΜΕ ΤΟ ΣΥΣΤΗΜΑ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΤΟΥ ΚΤΙΡΙΟΥ. ΤΟ BAS ή Ο ΧΕΙΡΙΣΤΗΣ ΠΡΕΠΕΙ ΝΑ ΕΧΟΥΝ ΤΗΝ ΔΥΝΑΤΟΤΗΤΑ ΝΑ ΠΡΟΣΔΙΟΡΙΣΟΥΝ ΠΟΙΑ ΑΝΤΛΙΑ ΘΑ ΕΙΝΑΙ ΣΕ ΛΕΙΤΟΥΡΓΙΑ (ή ΚΥΡΙΑ) ΚΑΙ Η ΑΛΛΗ ΣΕ ΕΦΕΔΡΙΑ (ή ΣΕ ΑΝΑΜΟΝΗ). ΤO BAS/Ο ΧΕΙΡΙΣΤΗΣ ΠΡΕΠΕΙ ΝΑ ΕΧΕΙ ΤΗΝ
ΙΚΑΝΟΤΗΤΑ ΝΑ ΑΝΤΙΣΤΡΕΨΕΙ ΤΗΝ ΑΚΟΛΟΥΘΙΑ ΑΥΤΟΜΑΤΑ ΣΥΜΦΩΝΑ ΜΕ ΤΑ ΑΚΟΛΟΥΘΑ:
1. ΧΕΙΡΟΚΙΝΗΤΑ ΜΕΣΩ ΕΝΟΣ ΔΙΑΚΟΠΤΗ ΛΟΓΙΣΜΙΚΟΥ.
2. ΧΡΟΝΟ ΛΕΙΤΟΥΡΓΙΑΣ ΤΗΣ ΑΝΤΛΙΑΣ.
3. ΠΡΟΓΡΑΜΜΑΤΙΖΟΜΕΝΑ, ΕΤΣΙ ΩΣΤΕ ΝΑ ΕΝΑΛΛΑΣΕΤΑΙ Η ΑΚΟΛΟΥΘΙΑ ΜΙΑ ΦΟΡΑ ΤΗΝ ΗΜΕΡΑ, ΤΗΝ ΕΒΔΟΜΑΔΑ, ΤΟ ΜΗΝΑ, ΤΗΝ ΕΠΟΧΗ Κ.Ο.Κ..
Η ΕΝ ΛΕΙΤΟΥΡΓΙΑ ΑΝΤΛΙΑ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΕΚΚΙΝΗΣΕΙ ΠΡΙΝ ΤΗΝ ΕΝΤΟΛΗ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ ΝΑ ΕΝΕΡΓΟΠΟΙΗΘΕΙ. ΟΤΑΝ Η ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ, ΟΙ ΑΝΤΛΙΕΣ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΟΝΤΑΙ ΝΑ ΣΤΑΜΑΤΗΣΟΥΝ ΜΕΤΑ ΑΠΟ ΜΙΑ ΧΡΟΝΙΚΗ ΚΑΘΥΣΤΕΡΗΣΗ 5 ΛΕΠΤΩΝ (ΡΥΘΜΙΖΟΜΕΝΗ). ΚΑΤΑ ΤΗΝ ΑΣΤΟΧΙΑ ΤΗΣ ΕΝ ΛΕΙΤΟΥΡΓΙΑ ΑΝΤΛΙΑΣ Η ΕΦΕΔΡΙΚΗ ΑΝΤΛΙΑ ΠΡΕΠΕΙ ΝΑ ΕΚΚΙΝΕΙ ΚΑΙ Η ΕΝ ΛΕΙΤΟΥΡΓΙΑ ΑΝΤΛΙΑ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΣΤΑΜΑΤΗΣΕΙ. Η ΑΣΤΟΧΙΑ ΤΗΣ ΑΝΤΛΙΑΣ ΠΡΕΠΕΙ ΝΑ ΚΑΘΟΡΙΖΕΤΑΙ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΤΟΝ
ΠΙΝΑΚΑ ΤΩΝ ΣΥΝΑΓΕΡΜΩΝ ΑΣΤΟΧΙΑΣ.
ΟΤΑΝ ΜΙΑ ΑΝΤΛΙΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΕΚΚΙΝΗΣΕΙ ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΣΤΗΝ ΕΛΑΧΙΣΤΗ ΤΑΧΥΤΗΤΑ ΤΟΥ VFD ΚΑΙ ΜΕΤΑ ΝΑ ΚΛΙΜΑΚΩΝΕΤΑΙ ΩΣ ΑΠΑΙΤΕΙΤΑΙ ΑΠΟ ΤΟ ΣΥΣΤΗΜΑ ΕΛΕΓΧΟΥ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗ ΚΑΙ ΕΤΣΙ ΩΣΤΕ ΝΑ ΔΙΑΤΗΡΕΙ ΤΗΝ ΕΛΑΧΙΣΤΗ ΑΠΑΙΤΟΥΜΕΝΗ ΡΟΗ ΜΕΣΑ ΣΤΗΝ ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ. ΟΤΑΝ ΜΙΑ ΑΝΤΛΙΑ ΕΝΤΕΛΛΕΤΑΙ ΝΑ ΣΤΑΜΑΤΗΣΕΙ ΠΡΕΠΕΙ ΑΡΧΙΚΑ ΝΑ ΣΥΝΕΧΙΣΕΙ ΝΑ ΛΕΙΤΟΥΡΓΕΙ ΓΙΑ ΕΝΑ ΙΚΑΝΟΠΟΙΗΤΙΚΟ ΧΡΟΝΙΚΟ ΔΙΑΣΤΗΜΑ ΚΑΘΥΣΤΕΡΗΣΗΣ (ΑΡΧΙΚΗ ΡΥΘΜΙΣΗ: 5 ΛΕΠΤΑ, ΡΥΘΜΙΖΟΜΕΝΟ), ΕΠΕΙΤΑ ΚΛΙΜΑΚΩΤΑ ΣΤΗΝ ΕΛΑΧΙΣΤΗ
ΤΑΧΥΤΗΤΑ ΤΟΥ VFD ΚΑΙ ΜΕΤΑ ΝΑ ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ.
Ο ΕΛΕΓΚΤΗΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΕΙ ΤΟΥΣ ΑΙΣΘΗΤΗΡΕΣ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΚΑΙ ΝΑ ΜΕΤΑΒΑΛΕΙ ΤΗΝ ΤΑΧΥΤΗΤΑ ΤΩΝ VFD ΤΩΝ ΑΝΤΛΙΩΝ ΓΙΑ ΝΑ ΔΙΑΤΗΡΟΥΝΤΑΙ ΤΑ ΠΡΟΚΑΘΟΡΙΜΕΝΑ ΣΗΜΕΙΑ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΤΟΥ ΚΑΘΕ ΑΙΣΘΗΤΗΡΑ (ΑΡΧΙΚΑ ΠΡΟΚΑΘΟΡΙΣΜΕΝΑ ΣΗΜΕΙΑ 10 10 FT W.C. (ΡΥΘΜΙΖΟΜΕΝΑ), ΤΑ ΤΕΛΙΚΑ ΣΗΜΕΙΑ ΡΥΘΜΙΣΗΣ ΘΑ ΠΡΟΣΔΙΟΡΙΣΤΟΥΝ ΚΑΤΑ ΤΗΝ ΕΞΙΣΟΡΡΟΠΗΣΗ ΚΑΙ ΤΗΝ ΔΟΚΙΜΗ). ΚΑΤΑ ΤΗΝ ΠΤΩΣΗ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΤΟΥ ΔΙΚΤΥΟΥ, Η ΤΑΧΥΤΗΤΑ ΤΗΣ ΑΝΤΛΙΑΣ ΠΡΕΠΕΙ ΝΑ ΑΥΞΑΝΕΤΑΙ ΚΑΤΑΛΛΗΛΩΣ. ΚΑΤΑ ΤΗΝ ΑΥΞΗΣΗ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ, Η ΤΑΧΥΤΗΤΑ ΤΗΣ ΑΝΤΛΙΑΣ ΠΡΕΠΕΙ ΝΑ ΜΕΙΩΝΕΤΑΙ ΚΑΤΑΛΛΗΛΩΣ ΕΝΩ ΘΑ ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΗΡΕΙ ΤΗΝ ΕΛΑΧΙΣΤΗ ΡΟΗ ΜΕΣΑ ΣΤΗΝ ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ (ΣΕ ΣΥΝΔΥΑΣΜΟ ΜΕ ΤΗΝ ΧΡΗΣΗ ΤΗΣ ΒΑΛΒΙΔΑΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΠΑΡΑΚΑΜΨΗΣ). Η ΕΛΑΧΙΣΤΗ ΤΑΧΥΤΗΤΑ ΤΗΣ ΑΝΤΛΙΑΣ ΘΑ ΣΥΝΑΔΕΙ ΜΕ
ΤΗΝ ΕΛΑΧΙΣΤΗ ΡΟΗ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ.
ΣΥΝΑΓΕΡΜΟΙ ΑΣΤΟΧΙΑΣ: Η ΑΝΤΛΙΑ ΠΟΥ ΑΣΤΟΧΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΚΛΕΙΣΤΗ. ΕΝΑ ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΕΤΑΙ ΣΤΟ BAS ΩΣ ΑΚΟΛΟΥΘΩΣ:
1. ΑΣΤΟΧΙΑ ΑΝΤΛΙΑΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ: Η ΕΝΤΟΛΗ ΕΙΝΑΙ ΣΕ ΛΕΙΤΟΥΡΓΙΑ, ΑΛΛΑ Η ΚΑΤΑΣΤΑΣΗ ΕΙΝΑΙ ΣΕ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ.
2. ΧΕΙΡΟΚΙΝΗΤΗ ΛΕΙΤΟΥΡΓΙΑ ΤΗΣ ΑΝΤΛΙΑΣ ΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ: Η ΕΝΤΟΛΗ ΕΙΝΑΙ ΚΛΕΙΣΤΗ, ΑΛΛΑ Η ΚΑΤΑΣΤΑΣΗ ΕΙΝΑΙ ΣΕ ΛΕΙΤΟΥΡΓΙΑ.
3. ΑΣΤΟΧΙΑ ΤΟΥ VFD ΤΗΣ ΑΝΤΛΙΑΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ.
ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΜΗ ΑΣΤΟΧΙΑΣ: Η ΑΝΤΛΙΑ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΕΝΤΕΛΛΕΤΑΙ ΚΛΕΙΣΤΗ. ΤΟ ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΠΡΕΠΕΙ ΝΑ ΣΤΑΛΕΙ ΣΤΟ BAS ΩΣ ΑΚΟΛΟΥΘΩΣ:
1. ΥΠΕΡΒΑΣΗ ΧΡΟΝΙΚΟΥ ΟΡΙΟΥ ΛΕΙΤΟΥΡΓΙΑΣ ΤΗΣ ΑΝΤΛΙΑΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ: Η ΚΑΤΑΣΤΑΣΗ ΤΟΥ ΧΡΟΝΙΚΟΥ ΟΡΙΟΥ ΛΕΙΤΟΥΡΓΙΑΣ ΥΠΕΡΒΑΙΝΕΙ ΤΟ ΟΡΙΖΟΜΕΝΟ ΑΠΟ ΤΟΝ ΧΡΗΣΤΗ
ΟΡΙΟ.
ΕΛΑΧΙΣΤΗ ΡΟΗ ΠΑΡΑΚΑΜΨΗΣ:
Η ΒΑΛΒΙΔΑ ΕΛΕΓΧΟΥ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΤΗΣ ΠΑΡΑΚΑΜΨΗΣ (FCV-01) ΠΡΕΠΕΙ ΝΑ ΡΥΘΜΙΖΕΙ ΑΝΟΙΚΤΗ ΚΑΤΑ ΤΗΝ ΠΤΩΣΗ ΤΗΣ ΡΟΗΣ ΜΕΣΩ ΤΟΥ ΑΙΣΘΗΤΗΡΑ ΡΟΗΣ (FT-01) ΚΑΤΩ ΑΠΟ ΤΗΝ ΕΛΑΧΙΣΤΗ ΡΟΗ ΠΟΥ ΧΡΕΙΑΖΕΤΑΙ ΓΙΑ ΤΗΝ ΔΙΑΤΗΡΗΣΗ ΤΗΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ. Η ΒΑΛΒΙΔΑ ΕΛΕΓΧΟΥ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ (FCV-01) ΠΡΕΠΕΙ ΝΑ ΠΑΡΑΜΕΙΝΕΙ ΚΛΕΙΣΤΗ ΟΤΑΝ Η ΔΙΑΦΟΡΙΚΗ ΡΟΗ ΕΙΝΑΙ ΑΝΩ ΤΗΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΤΗΣ ΑΝΤΛΙΑΣ ΘΕΡΜΟΤΗΤΑΣ. Η ΕΛΑΧΙΣΤΗ ΡΟΗ ΣΧΕΔΙΑΣΜΟΥ ΓΙΑ ΤΗΝ ΑΝΤΛΙΑ ΘΕΡΜΟΤΗΤΑΣ ΠΡΕΠΕΙ ΝΑ ΔΙΕΥΚΡΙΝΙΣΤΕΙ ΜΕ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ. ΠΡΟΜΗΘΕΥΣΤΕ ΒΑΛΒΙΔΑ ΠΑΡΑΚΑΜΨΗΣ ΕΛΑΧΙΣΤΗΣ ΡΟΗΣ ΠΟΥ ΠΑΡΑΜΕΝΕΙ ΑΝΟΙΧΤΗ ΣΕ ΠΕΡΙΠΤΩΣΗ ΣΦΑΛΜΑΤΟΣ, ΜΕ ΚΑΛΩΔΙΩΣΗ ΣΤΟ ΙΔΙΟ DDC ΠΙΝΑΚΑ ΜΕ ΤΟΝ ΨΥΚΤΗ.
ΕΠΑΝΑΠΡΟΣΔΙΟΡΙΣΜΟΣ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ (DP-01):
ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΠΡΕΠΕΙ ΝΑ ΕΠΑΝΑΠΡΟΣΔΙΟΡΙΣΤΕΙ ΠΡΟΣ ΤΑ ΚΑΤΩ ΓΙΑ ΤΗΝ ΔΙΑΤΗΡΗΣΗ ΚΑΤΑ ΜΕΓΙΣΤΟ 1 (ΡΥΘΜΙΖΟΜΕΝΟ) ΒΑΛΒΙΔΑΣ ΕΛΕΓΧΟΥ ΣΕ ΕΝΑ ΜΕΓΙΣΤΟ 90% (ΡΥΘΜΙΖΟΜΕΝΟ) ΑΝΟΙΚΤΗ. ΟΣΟ ΠΕΡΙΣΟΤΕΡΕΣ ΒΑΛΒΙΔΕΣ ΕΛΕΓΧΟΥ ΑΝΟΙΓΟΥΝ Ο ΕΠΑΝΑΠΡΟΣΔΙΟΡΙΣΜΟΣ ΤΗΣ ΔΙΑΦΟΡΙΚΗΣ ΠΙΕΣΗΣ ΘΑ ΓΙΝΕΤΑΙ ΠΡΟΣ ΤΑ ΠΑΝΩ ΠΡΟΣ
ΤΟ ΠΡΟΚΑΘΟΡΙΣΜΕΝΟ ΣΗΜΕΙΟ ΤΗΣ ΠΙΕΣΗΣ ΠΟΥ ΚΑΘΙΕΡΩΘΗΚΕ ΚΑΤΑ ΤΗΝ ΕΞΙΣΟΡΡΟΠΗΣΗ.
ΠΡΟΣΤΑΣΙΑ ΠΑΓΟΠΟΙΗΣΗΣ:
ΟΤΑΝ Η ΘΕΡΜΟΚΡΑΣΙΑ ΤΟΥ ΕΞΩΤΕΡΙΚΟΥ ΑΕΡΑ ΕΙΝΑΙ ΚΑΤΩ ΤΩΝ 4.0oC (ΡΥΘΜΙΖΟΜΕΝΟ), ΤΟ BAS ΠΡΕΠΕΙ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙ ΤΗΝ ΑΝΤΛΙΑ ΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ, ΚΑΙ ΝΑ ΑΝΟΙΓΕΙ ΤΙΣ
ΒΑΛΒΙΔΕΣ ΤΟΥ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ ΣΤΙΣ AHU, ΚΑΙ ΤΙΣ DOAS TOYΛΑΧΙΣΤΟΝ 20%.
ΑΚΟΛΟΥΘΙΑ ΛΕΙΤΟΥΡΓΙΑΣ ΣΥΣΤΗΜΑΤΟΣ ΝΕΡΟΥ ΘΕΡΜΑΝΣΗΣ
A
M E
N D
M E
N T
-2
-2
| Sheets |
| M-811 - CHILLED WATER SYSTEM - SEQUENCE OF OPERATIONS |
| M-813 - HEATING WATER SYSTEM - SEQUENCE OF OPERATIONS |
2021-09-24T08:56:10-0500
2021-09-24T08:56:27-0500
2021-09-24T08:56:59-0500
2021-09-24T08:57:18-0500
File details come from the government source that posted it. Updated .