ATT H 1615269dwg10of19.pdf
PDF 1 MB Posted
- Attached to
- P131 Communications Center - Souda Bay
- Solicitation number
- N62470-21-R-0005
About this file
This solicitation is for a design-bid-build, firm fixed price contract to construct a communications center at Naval Support Activity Souda Bay, Greece. The project will construct a three-story cast-in-place concrete structure with concrete shear walls and shallow foundations to house a new communications center, telephone exchange, electronics maintenance shops, and storage for electronics spares and equipment. Electrical utilities will include primary and secondary distribution systems, transformers, substation upgrades, telecommunications infrastructure, security systems infrastructure and lighting. The period of performance is approximately 900 days after notice to proceed. The Naval Facilities Engineering Command will award the contract on an unrestricted, full and open competitive basis.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE ALARM / MASS NOTIFICATION SYSTEM LEGEND
ΥΠΟΜΝΗΜΑ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
FIRE ALARM / MASS NOTIFICATION SYSTEM GENERAL NOTES
ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ / ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
SYMBOL
ΣΥΜΒΟΛΟ
DESCRIPTION
ΠΕΡΙΓΡΑΦΗ
COMBINATION FIRE ALARM / MASS NOTIFICATION CONTROL PANEL
ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΝΔΥΑΜΟΥ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
AMPLIFIER PANEL
ΠΙΝΑΚΑΣ ΕΝΙΣΧΥΤΗ
SMOKE DETECTOR, (X) = TYPE
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ, (Χ) = ΤΥΠΟΣ
P = PHOTOELECTRIC
SB = SOUND BASER
DUCT SMOKE DETECTOR
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΑΕΡΑΓΩΓΟΥ
KEY LOCK BOX RAPID ENTRY SYSTEM
ΚΟΥΤΙ ΚΛΕΙΔΟΘΗΚΗΣ ΣΥΣΤΗΜΑΤΟΣ ΤΑΧΕΙΑΣ ΕΙΣΟΔΟΥ
TAMPER SWITCH
ΔΙΑΚΟΠΤΗΣ ΔΙΑΦΡΑΓΜΑΤΟΣ
FLOW SWITCH
ΔΙΑΚΟΠΤΗΣ ΡΟΗΣ
EXTERIOR MNS SPEAKER WALL MOUNT AS SHOWN
WP = WEATHERPROOF
ΕΞΩΤΕΡΙΚΟ ΜΕΓΑΦΩΝΟ ΤΟΥ MNS ΕΠΙΤΟΙΧΟ ΟΠΩΣ ΔΕΙΧΝΕΤΑΙ
WP = ΑΔΙΑΒΡΟΧΟ
AT A MINIMUM THE FOLLOWING CODES AND STANDARDS APPLY:
NFPA 70 - NATIONAL ELECTRICAL CODE (NEC) - 2020 EDITION
NFPA 72 - NATIONAL FIRE ALARM AND SIGNALING CODE - 2019 EDITION
NFPA 76 - STANDARD FOR THE FIRE PROTECTION OF TELECOMMUNICATIONS FACILITIES - 2020 EDITION
NFPA 101 - LIFE SAFETY CODE (LSC) - 2018 EDITION
NFPA 720 - CARBON MONOXIDE DETECTION
NFPA 2001 - STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS - 2018 EDITION
UFC 3-520-01 - INTERIOR ELECTRICAL SYSETMS - CHANGE 1, 20 MARCH 2019
UFC 3-600-01 - FIRE PROTECTION ENGINEERING FOR FACILITIES - CHANGE 5, 12 AUGUST 2020 UFC 4-010-01 - DOD MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDINGS - 12 DECEMBER 2018 UFC 4-021-01 - DESIGN AND O&M: MASS NOTIFICATION SYSTEMS - CHANGE 1, JANUARY 2010
ΚΑΤ' ΕΛΑΧΙΣΤΟ ΟΙ ΑΚΟΛΟΥΘΟΙ ΚΩΔΙΚΕΣ ΚΑΙ ΠΡΟΤΥΠΑ ΠΡΕΠΕΙ ΝΑ ΕΦΑΡΜΟΖΟΝΤΑΙ:
NFPA 70 - ΑΜΕΡΙΚΑΝΙΚΟΣ ΗΛΕΚΤΙΚΟΣ ΚΩΔΙΚΑ (NEC) - ΕΚΔΟΣΗ 2020
NFPA 72 - ΑΜΕΡΙΚΑΝΙΚΟΣ ΚΩΔΙΚΑΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΙ ΣΗΜΑΤΟΔΟΣΙΑΣ - ΕΚΔΟΣΗ 2019 NFPA 76 - ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΚΩΝ ΕΓΚΑΤΑΣΤΑΣΕΩΝ - ΕΚΔΟΣΗ 2020
NFPA 101 - ΚΩΔΙΚΑΣ ΑΣΦΑΛΕΙΑΣ ΖΩΗΣ (LSC) - ΕΚΔΟΣΗ 2019
NFPA 720 - ΑΝΙΧΝΕΥΣΗ ΜΟΝΟΞΕΙΔΙΟΥ ΤΟΥ ΑΝΘΡΑΚΑ
NFPA 2001 - ΠΡΟΤΥΠΟ ΓΙΑ ΤΑ ΣΥΣΤΗΜΑΤΑ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ - ΕΚΔΟΣΗ 2018
UFC 3-520-01 - ΕΣΩΤΕΡΙΚΑ ΗΛΕΚΤΙΚΑ ΣΥΣΤΗΜΑΤΑ - ΑΛΛΑΓΗ 1, 20 ΜΑΡΤΙΟΥ 2019
UFC 3-600-01 - ΜΗΧΑΝΙΚΗ ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΕΓΚΑΤΑΣΤΑΣΕΩΝ - ΑΛΛΑΓΗ 5, 12 ΑΥΓΟΥΣΤΟΥ 2020 UFC 4-010-01 - DOD ΕΛΑΧΙΣΤΑ ΑΝΤΙΤΡΟΜΟΚΡΑΤΙΚΑ ΠΡΟΤΥΠΑ ΓΙΑ ΚΤΗΡΙΑ - 12 ΔΕΚΕΜΒΡΙΟΥ 2018 UFC 4-021-01 - ΣΧΕΔIΑΣΜΟΣ ΚΑΙ O&M¨ΣΥΣΤΗΜΑΤΑ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ - ΑΛΛΑΓΗ 1, ΙΑΝΟΥΑΡΙΟΣ 2010
Ρ= ΦΩΤΟΗΛΕΚΤΡΙΚΟΣ
SB = ΗΧΗΤΙΚΟΣ
K
WP
2.
1.
BECOME FAMILIAR WITH THE DETAILS OF WORK, VERIFY DIMENSIONS IN THE FIELD, AND ADVISE THE CONTRACTING OFFICER OF ANY DISCREPANCIES BEFORE PERFORMING ANY WORK. COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE CONTRACTOR'S QUALIFIED FIRE PROTECTION ENGINEER AND AUTHORITY HAVING JURISDICITON. ANY DISCREPANCIES OR DEFICIENCIES MUST BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
ΕΞΟΙΚΕΙΩΘΕΙΤΕ ΜΕ ΤΙΣ ΛΕΠΤΟΜΕΡΕΙΕΣ ΤΩΝ ΕΡΓΑΣΙΩΝ, ΕΠΙΒΕΒΑΙΩΣΤΕ ΤΙΣ ΔΙΑΣΤΑΣΕΙΣ ΕΠΙ ΤΟΥ ΠΕΔΙΟΥ ΚΑΙ ΣΥΜΒΟΥΛΕΥΤΕΙΤΕ ΤΟΝ ΑΞΙΩΜΑΤΙΚΟ ΤΟΥ ΕΡΓΟΥ ΓΙΑ ΟΠΟΙΕΣ ΑΣΥΜΦΩΝΙΕΣ ΠΡΙΝ ΟΠΟΙΑΔΗΠΟΤΕ ΕΡΓΑΣΙΑ. ΣΥΝΤΟΝΙΣΤΕ ΟΛΑ ΤΑ ΑΠΑΙΤΟΥΜΕΝΑ ΣΥΣΤΗΜΑΤΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ ΜΗΧΑΝΙΚΟ ΠΥΡΑΣΦΑΛΕΙΑΣ ΤΟΥ ΕΡΓΟΛΑΒΟΥ ΚΑΙ ΤΗΝ ΑΡΜΟΔΙΑ ΑΡΧΗ. ΟΠΟΙΕΣΔΗΠΟΤΕ ΑΣΥΜΦΩΝΙΕΣ Ή ΕΛΛΕΙΨΕΙΣ ΠΡΕΠΕΙ ΝΑ ΔΙΟΡΘΩΘΟΥΝ ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ ΧΩΡΙΣ ΕΠΙΠΛΕΟΝ ΚΟΣΤΟΣ.
3. PROVIDE AN ADDRESSABLE COMBINED FIRE ALARM / MASS NOTIFICATION SYSTEM. PROVIDE A POINT REPORTING DIGITAL ALARM COMMUNICATOR TRANSMITTER THAT IS COMPATIBLE WITH THE EXISTING DIGITAL ALARM COMMUNICATOR RECEIVER AND IS PROGRAMMED TO REPORT BY POINTS VIA CONTACT ID PROTOCOL.
ΠΑΡΕΧΕΤΕ ΕΝΑΝ ΔΙΕΥΘΥΝΣΙΟΔΟΤΟΥΜΕΝΟ ΣΥΣΤΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΙ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ. ΠΑΡΕΧΕΤΕ ΕΝΑ ΣΗΜΕΙΟ ΔΙΑΔΟΣΗΣ ΨΗΦΙΑΚΟΥ ΜΕΤΑΦΟΡΕΑ ΔΙΑΒΙΒΑΣΗΣ ΣΥΝΑΓΕΡΜΟΥ ΠΟΥ ΝΑ ΕΙΝΑΙ ΣΥΜΒΑΤΟ ΜΕ ΤΟΝ ΥΠΑΡΧΟΝΤΑ ΨΗΦΙΑΚΟ ΔΕΚΤΗ ΔΙΑΒΙΒΑΣΗΣ ΣΥΝΑΓΕΡΜΟΥ ΚΑΙ ΕΙΝΑΙ ΠΡΟΓΡΑΜΜΑΤΙΣΜΕΝΟΣ ΝΑ ΜΕΤΑΔΙΔΕΙ ΑΠΟ
ΣΗΜΕΙΑ ΔΙΑ ΜΕΣΟΥ ΠΡΩΤΟΚΟΛΛΟΥ ΕΠΑΦΩΝ ID.
4.
ALL CONDUCTORS MUST BE INSTALLED IN MINIMUM 20 MM CONDUIT. PROVIDE CLASS B PATHWAYS FOR INTIATING DEVICE CIRCUITS, SIGNALING LINE CIRCUITS, AND NOTFICIATION APPLIANCE CIRCUITS. CONDUCTORS MUST BE SOLID OR STRANDED COPPER. SIGNALING LINE CIRCUITS MUST BE A MINIMUM 18 AWG. INITIATING DEVICE
CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS MUST BE A MINIMUM 16 AWG.
ΟΛΟΙ ΟΙ ΑΓΩΓΟΙ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΜΕΣΑ ΣΕ ΚΑΤ' ΕΛΑΧΙΣΤΟ 20ΜΜ ΣΩΛΗΝΑ ΚΑΛΩΔΙΟΥ . ΠΑΡΕΧΕΤΕ ΚΛΑΣΗΣ Β ΠΕΡΑΣΜΑΤΑ ΓΙΑ ΤΑ ΚΥΚΛΩΜΑΤΑ ΤΩΝ ΣΥΣΚΕΥΩΝ ΕΝΕΡΓΟΠΟΙΗΣΗΣ, ΓΙΑ ΤΑ ΚΥΚΛΩΜΑΤΑ ΤΩΝ ΓΡΑΜΜΩΝ ΣΗΜΑΤΟΔΟΣΙΑΣ ΚΑΙ ΤΑ ΚΥΚΛΩΜΑΤΑ ΣΥΣΚΕΥΩΝ ΕΙΔΟΠΟΙΗΣΗΣ. ΤΑ ΚΥΚΛΩΜΑΤΑ ΣΥΣΚΕΥΩΝ ΕΝΕΡΓΟΠΟΙΗΣΗΣ ΚΑΙ ΤΑ
ΚΥΚΛΩΜΑΤΑ ΣΥΣΚΕΥΩΝ ΕΙΔΟΠΟΙΗΣΗΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤ' ΕΛΑΧΙΣΤΟ 16 AWG.
5.
ALL EXPOSED CONDUIT, JUNCTION/BACK BOXES, AND COVERS/COUPLINGS MUST BE FACTORY PAINTED RED IN UNFINISHED AREAS. ALL EXPOSED CONDUIT, JUNCTION/BACK BOXES, AND COVERS/COUPLINGS MUST BE PAINTED TO MATCH ADJACENT SURFACES IN FINISHED AREAS. WHERE COMPONENTS ARE PAINTED TO MATCH THE ADJACENT SURFACE THE INSIDE COVER OF THE JUNCTION BOX MUST BE LABELED "FIRE ALARM".
ΟΛΟΙ ΟΙ ΕΚΤΕΘΕΙΜΕΝΟΙ ΣΩΛΗΝΕΣ ΚΑΛΩΔΙΩΝ, ΤΑ ΚΟΥΤΙΑ / ΚΟΥΤΙΑ ΔΙΑΚΛΑΔΩΣΗΣ KAI TA ΚΑΛΥΜΜΑΤΑ ΚΑΙ ΟΙ ΣΥΖΕΥΚΤΗΡΕΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΕΡΓΟΣΤΑΣΙΑΚΑ ΒΑΜΜΕΝΑ ΚΟΚΚΙΝΑ ΣΕ ΜΗ ΤΕΛΕΙΩΜΕΝΟΥΣ ΧΩΡΟΥΣ. ΟΛΟΙ ΟΙ ΕΚΤΕΘΕΙΜΕΝΟΙ ΣΩΛΗΝΕΣ ΚΑΛΩΔΙΩΝ, ΤΑ ΚΟΥΤΙΑ / ΚΟΥΤΙΑ ΔΙΑΚΛΑΔΩΣΗΣ ΚΑΙ ΤΑ ΚΑΛΥΜΜΑΤΑ ΚΑΙ ΟΙ ΣΥΖΕΥΚΗΤΡΕΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΒΑΜΜΕΝΑ ΕΤΣΙ ΩΣΤΕ ΝΑ ΤΑΙΡΙΑΖΟΥΝ ΜΕ ΤΙΣ ΠΑΡΑΚΕΙΜΕΝΕΣ ΕΠΦΑΝΕΙΕΣ ΣΕ ΤΕΛΕΙΩΜΕΝΟΥΣ ΧΩΡΟΥΣ. ΟΠΟΥ ΤΑ ΤΜΗΜΑΤΑ ΒΑΦΟΝΤΑΙ ΓΙΑ ΝΑ ΤΑΙΡΙΑΖΟΥΝ ΜΕΤ ΤΙΣ ΠΑΡΑΚΕΙΜΕΝΕΣ ΕΠΙΦΑΝΕΙΕΣ ΤΟ ΕΣΩΤΕΡΙΚΟ ΚΑΛΥΜΜΑ ΤΟΥ ΚΟΥΤΙ ΔΙΑΚΛΑΔΩΣΗΣ ΠΡΕΠΕΙ ΝΑ ΑΝΑΓΡΑΦΕΙ "ΣΥΝΑΓΕΡΜΟΣ ΠΥΡΚΑΓΙΑΣ".
6.
ROUTE CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. WIRE NUTS, CRIMPED CONNECTORS, OR TWISTING OF CONDUCTORS IS PROHIBITED. RUN WIRING TO CONTROL PANELS IN THE VERTICAL OR HORIZONTAL PLANE, MAKE TURNS AT 90 DEGREE ANGLES, AND TIGHTLY BUNDLE, WRAP AND IDENTIFY CONDUCTORS INDIVIDUALLY WITH PERMANENT MARKINGS. CONDUCTOR MARKINGS MUST BE PRINTED LABLES PERMANENTLY AFFIXED TO THE CONDUCTOR WITH SHRINK WRAP.
ΔΡΟΜΟΛΟΓΗΣΤΕ ΑΓΩΓΟΥΣ ΑΠΟ ΣΥΣΚΕΥΗ ΣΕ ΣΥΣΚΕΥΗ ΧΩΡΙΣ ΣΥΝΔΕΣΕΙΣ. ΑΠΑΓΟΡΕΥΟΝΤΑΙ ΟΙ ΣΥΝΔΕΤΗΡΕΣ ΚΑΛΩΔΙΩΝ, ΟΙ ΚΛΕΜΜΕΣ ΚΑΙ Η ΣΥΣΤΡΟΦΗ ΤΩΝ ΑΓΩΓΩΝ.
ΔΙΑΤΕΞΤΕ ΤΗΝ ΚΑΛΩΔΙΩΣΗ ΠΡΟΣ ΤΟΥΣ ΠΙΝΑΚΕΣ ΕΛΕΓΧΟΥ ΣΕ ΚΑΘΕΤΟ Ή ΟΡΙΖΟΝΤΙΟ ΕΠΙΠΕΔΟ, ΚΑΝΕΤΕ ΣΤΡΟΦΕΣ 90 ΜΟΙΡΩΝ ΚΑΙ ΔΕΜΑΤΙΑΣΤΕ ΣΦΙΧΤΑ, ΤΥΛΙΞΤΕ ΚΑΙ ΠΡΟΣΔΙΟΡΙΣΤΕ ΤΟΥΣ ΑΓΩΓΟΥΣ ΞΕΧΩΡΙΣΤΑ ΜΕ ΜΟΝΙΜΕΣ ΕΠΙΓΡΑΦΕΣ. ΟΙ ΕΠΙΓΡΑΦΕΣ ΤΩΝ ΑΓΩΓΩΝ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΤΥΠΩΜΕΝΕΣ ΕΤΙΚΕΤΕΣ ΜΟΝΙΜΑ ΚΟΛΛΗΜΕΝΕΣ ΣΤΟΝ
ΑΓΩΓΟ ΜΕ ΔΙΑΦΑΝΗ ΜΕΜΒΡΑΝΗ .
8.
CUTTING STRUCTURAL MEMBERS OR REINFORCING FOR PASSAGE OF PIPES OR FOR PIPE-HANGER FASTENINGS WILL NOT BE PERMITTED. PIPES THAT MUST PENETRATE CONCRETE WALLS OR CONCRETE FLOORS MUST BE PROVIDED WITH CAST-IN-PLACE PIPE SLEEVES. PIPES THAT MUST PENETRATE MASONRY WALLS
MUST BE CORE-DRILLED WITHOUT CUTTING REINFORCING AND PROVIDED WITH PIPE SLEEVES.
ΔΕΝ ΕΠΙΤΡΕΠΕΤΑΙ Η ΚΟΠΗ ΔΟΜΙΚΩΝ ΣΤΟΙΧΕΙΩΝ Ή ΤΗΣ ΟΠΛΙΣΗΣ ΓΙΑ ΤΗ ΔΙΕΛΕΥΣΗ ΣΩΛΗΝΩΝ Ή ΤΗ ΣΤΕΡΕΩΣΗ ΣΤΗΡΙΓΜΑΤΩΝ ΣΩΛΗΝΩΝ. ΟΙ ΣΩΛΗΝΕΣ ΠΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΡΗΣΟΥΝ ΤΟΙΧΟΥΣ ΣΚΥΡΟΔΕΜΑΤΟΣ Ή ΔΑΠΕΔΑ ΣΚΥΡΟΔΕΜΑΤΟΣ ΠΡΕΠΕΙ ΝΑ ΠΑΕΡΧΟΝΤΑΙ ΜΕ ΜΑΝΔΥΕΣ ΣΩΛΗΝΩΣΕΩΝ ΕΠΙΤΟΠΙΑΣ ΣΚΥΡΟΔΕΤΗΣΗΣ. Η ΔΙΑΤΡΗΣΗ ΣΩΛΗΝΩΝ ΠΟΥ ΠΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΤΡΗΣΟΥΝ ΠΛΙΝΘΟΚΤΙΣΤΗ ΤΟΙΧΟΠΟΙΙΑ ΠΡΕΠΕΙ ΝΑ ΓΙΝΕΤΑΙ ΜΕ ΚΑΡΟΤΙΕΡΑ ΧΩΡΙΣ ΝΑ ΚΟΒΕΤΑΙ Η ΟΠΛΙΣΗ ΚΑΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ
ΜΑΝΔΥΕΣ ΣΩΛΗΝΩΝ.
7.
PROVIDE VISUAL NOTIFICATION APPLIANCES IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 72. ALL VISUAL NOTIFICATION APPLIANCES MUST HAVE THE FLASH RATES SYNCHRONIZED.
ΠΑΡΑΧΕΤΕ ΣΥΣΚΕΥΕΣ ΟΠΤΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΣΥΜΦΩΝΑ ΜΕ ΤΟ UFC 3-600-01 ΚΑΙ ΤΟ NFPA 72. ΟΛΕΣ ΟΙ ΣΥΣΚΕΥΕΣ ΟΠΤΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΠΡΕΠΕΙ ΝΑ ΕΧΟΥΝ ΣΥΓΧΡΟΝΙΣΜΕΝΟ ΡΥΡΘΜΟ
ΦΩΤΙΣΜΟΥ.
PROVIDE A DEDICATED EMERGENCY PANEL FOR FIRE ALARM CIRCUITS. REFER TO THE ELECTRICAL DRAWINGS FOR MORE INFORMATION.
ΠΑΡΕΧΕΤΕ ΕΝΑΝ ΑΠΟΚΛΕΙΣΤΙΚΟ ΠΙΝΑΚΑ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ ΓΙΑ ΤΑ ΚΥΚΛΩΜΑΤΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ. ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ
ΣΧΕΔΙΑ ΓΙΑ ΠΕΡΙΣΣΟΤΕΡΕΣ ΠΛΗΡΟΦΟΡΙΕΣ.
9.
FMCP
LOC
ANN
AMP
TXT
LOCAL OPERATING CONSOLE
ΚΟΝΣΟΛΑ ΤΟΠΙΚΟΥ ΧΕΙΡΙΣΤΗ
ANNUNCIATOR PANEL
ΠΙΝΑΚΑΣ ΑΝΑΓΓΕΛΙΩΝ
MASS NOTIFICATION SYSTEM TEXTUAL DISPLAY
ΓΡΑΦΙΚΗ ΑΝΑΠΑΡΑΣΤΑΣΗ ΣΥΣΤΗΜΑΤΟΣ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
ADDRESSABLE INPUT MONITOR MODULE
ΔΙΕΥΘΥΝΣΙΟΔΟΤΟΥΜΕΝΗ ΜΟΝΑΔΑ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΕΙΣΟΔΟΥ
ADDRESSABLE OUTPUT CONTROL MODULE
ΔΙΕΥΘΥΝΣΙΟΔΟΤΟΥΜΕΝΗ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΕΞΟΔΟΥ
TWO-WAY EMERGENCY COMMUNICATIONS CONTROL UNIT
ΔΙΟΔΗ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΕΠΙΚΟΙΝΩΝΙΩΝ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ
AREA OF REFUGE TWO-WAY COMMUNICATION CALL STATION
ΔΙΟΔΟΣ ΣΤΑΘΜΟΣ ΚΛΗΣΕΩΝ ΕΠΙΚΟΙΝΩΝΙΑΣ ΤΟΥ ΧΩΡΟΥ ΚΑΤΑΦΥΓΗΣ
CA MANUAL CLEAN AGENT DISCHARGE STATION
ΧΕΙΡΟΚΙΝΗΤΟΣ ΣΤΑΘΜΟΣ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT SYSTEM ABORT STATION
ΣΤΑΘΜΟΣ ΔΙΑΚΟΠΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑA
MOUNT THE OPERABLE PART OF MANUAL PULL AND CLEAN AGENT DISCHARGE STATIONS AT 915 MM AFF.
ΤΟΠΟΘΕΤΗΣΤΕ ΤΟ ΧΕΙΡΟΚΙΝΗΤΟ ΚΟΜΜΑΤΙ ΤΟΥ ΧΕΙΡΟΚΙΝΗΤΟΥ ΣΤΑΘΜΟΥ ΕΛΞΗΣ ΚΑΙ ΤΩΝ ΣΤΑΘΜΩΝ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ ΣΤΑ 915ΜΜ AFF.
10.
S
ECCU
MANUAL PULL STATION
ΧΕΙΡΟΚΙΝΗΤΟΣ ΣΤΑΘΜΟΣ ΕΛΞΗΣ
F
MASS NOTIFICATION TRANSMITTER
ΠΟΜΠΟΣ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
MNT
CM
IM
ABBREVIATIONS
ΣΥΝΤΟΜΕΥΣΕΙΣ
Ø
A
OMNIDIRECTIONAL ANTENNA
ΠΑΝΚΑΤΕΥΘΥΝΤΙΚΗ ΚΕΡΑΙΑ
FIRE SMOKE DAMPER
ΔΙΑΦΡΑΓΜΑ ΚΑΠΝΟΥ ΠΥΡΚΑΓΙΑΣ
co CARBON MONOXIDE DETECTOR
ΑΝΙΧΝΕΥΤΗΣ ΜΟΝΟΞΕΙΔΙΟΥ ΤΟΥ ΑΝΘΡΑΚΑ
- DIAMETER
- ΔΙΑΜΕΤΡΟΣ
- AMPERE
- ΑΜΠΕΡ
& - AND
- ΚΑΙ
@ - AT
- ΣΕ
A/C - AIR CONDITIONING
- ΜΟΝΑΔΑ ΚΛΙΜΑΤΙΣΜΟΥ
AHJ - NAVFC MIDLANT C145 FIRE PROTECTION ENGINEERING DEPARTMENT
- NAVGC MINDLAND C145 ΤΜΗΜΑ ΜΗΧΑΝΙΚΩΝ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ
AHU - AIR HANDLING UNIT
- ΜΟΝΑΔΑ ΔΙΑΧΕΙΡΙΣΗΣ ΑΕΡΑ
ALUM - ALUMINUM
- ΑΛΟΥΜΙΝΙΟΥ
AFF - ABOVE FINISHED FLOOR
- ΠΑΝΩ ΑΠΟ ΤΕΛΕΙΩΜΕΝΟ ΔΑΠΕΔΟ
APP - APPROXIMATE
- ΠΕΡΙΠΟΥ
BRKR - BREAKER
- ΔΙΑΚΟΠΤΗΣ
ºC - DEGREES CENTIGRADE
- ΒΑΘΜΟΙ ΚΕΛΣΙΟΥ
C - CONDUIT
- ΑΓΩΓΟΣ
CB - CIRCUIT BREAKER
- ΔΙΑΚΟΠΤΗΣ ΚΥΚΛΩΜΑΤΟΣ
CFM - CUBIC FEET PER MINUTE
- ΚΥΒΙΚΑ ΠΟΔΙΑ ΑΝΑ ΛΕΠΤΟ
CKT - CIRCUIT
- ΚΥΚΛΩΜΑ
CLG - CEILING
- ΟΡΟΦΗ
CMU - CONCRETE MASONRY UNIT
- ΜΟΝΑΔΑ ΤΟΙΧΟΠΟΙΙΑΣ ΣΚΥΡΟΔΕΜΑΤΟΣ
CONT - CONTINUATION
- ΣΥΝΕΧΕΙΑ
DEPT - DEPARTMENT
- ΤΜΗΜΑ
C/U - CEILING AND UNDERFLOOR
- ΟΡΟΦΗ ΚΑΙ ΥΠΟΔΑΠΕΔΙΟ
DWG - DRAWING
- ΣΧΕΔΙΟ
EA - EACH
- ΚΑΘΕ
ECB - ENCLOSED CIRCUIT BREAKER
- ΕΓΚΙΒΩΤΙΣΜΕΝΟΣ ΔΙΑΚΟΠΤΗΣ ΚΥΚΛΩΜΑΤΟΣ
ELEC - ELECTRICAL
- ΗΛΕΚΤΡΙΚΟΣ
ENCL - ENCLOSURE
- ΠΕΡΙΒΛΗΜΑ
EXP - EXPANSION
- ΕΠΕΚΤΑΣΗ
EXIST - EXISTING
- ΥΠΑΡΧΩΝ
FA - FIRE ALARM
- ΣΥΝΑΓΕΡΜΟΣ ΠΥΡΚΑΓΙΑΣ
FACP - FIRE ALARM CONTROL PANEL
- ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ
FA/MNS
- FIRE ALARM/MASS NOTIFICATION SYSTEM
- ΣΥΣΤΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
FLEX - FLEXIBLE
- ΕΥΚΑΜΠΤΟΣ
G - GROUND
- ΓΕΙΩΣΗ
FM - FACTORY MUTUAL APPROVED
- ΕΓΚΕΚΡΙΜΜΕΝΟ ΚΑΤΑ fM
GA - GAGE
- ΜΕΤΡΗΤΗΣ
GALV - GALVANIZED
- ΓΑΛΒΑΝΙΣΜΕΝΟ
GF - GOVERNMENT FURNISHED
- ΠΡΟΜΗΘΕΙΑ ΑΠΟ ΤΗΝ
ΚΥΒΕΡΝΗΣΗ
GI - GOVERNMENT INSTALLED
- ΕΓΚΑΤΑΣΤΑΣΗ ΑΠΟ ΤΗΝ
ΚΥΒΕΡΝΗΣΗ
GL - GRADE LINE
- ΓΡΑΜΜΗ ΒΑΘΜΟΛΟΓΗΣΗΣ
HP - HORSEPOWER
- ΙΠΠΟΔΥΝΑΜΗ
HR - HOUR
- ΩΡΑ
HZ - HERTZ
- ΧΕΡΤΖ
INCL - INCLUDING
- ΠΕΡΙΛΑΜΒΑΝΕΙ
KVA - KILOVOLT AMPERE
- ΚΙΛΟΒΟΛΤ ΑΜΠΕΡ
KW - KILOWATT
- ΚΙΛΟΒΑΤ
MAX - MAXIMUM
- ΜΕΓΙΣΤΟ
MECH - MECHANICAL
- ΜΗΧΑΝΟΛΟΓΙΚΟΣ
MIN - MINIMUM
- ΕΛΑΧΙΣΤΟ
MM - MILLIMETER
- ΜΙΛΙΜΕΤΡΟ
MISC - MISCELLANEOUS
- ΔΙΑΦΟΡΑ
MNS - MASS NOTIFICATION SYSTEM
- ΣΥΣΤΗΜΑ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
MTD - MOUNTED
- ΣΤΗΡΙΖΟΜΕΝΟΣ
N - NEUTRAL
- ΟΥΔΕΤΕΡΟΣ
NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCATION
- ΕΝΩΣΗ ΗΛΕΚΤΡΙΚΩΝ ΚΑΤΑΣΚΕΥΑΣΤΩΝ Η.Π.Α.
NO,# - NUMBER
- ΝΟΥΜΕΡΟ
OC - ON CENTER
- ΣΤΟ ΚΕΝΤΡΟ
QTY - QUANTITY
- ΠΟΣΟΤΗΤΑ
STD - STANDARD
- ΠΡΟΤΥΠΟ
TYP - TYPICAL
- ΤΥΠΙΚΟΣ
UL - UNDERWRITERS LABORATRIES
- ΑΝΕΞΑΡΤΗΤΑ ΕΡΓΑΣΤΗΡΙΑ ΔΟΚΙΜΩΝ
UNGD - UNDERGROUND
- ΥΠΟΓΕΙΟΣ
UNO - UNLESS NOTED OTHERWISE
- ΕΚΤΟΣ ΕΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
V - VOLTS, VOLTAGE
- ΒΟΛΤ, ΤΑΣΗ
VA - VOLT AMPERE
- ΒΟΛΤ ΑΜΠΕΡ
W/ - WITH
- ΜΕ
WP - WEATHER PROOF
- ΑΔΙΑΒΡΟΧΗ ΠΡΟΣΤΑΣΙΑ
SURGE PROTECTION DEVICE
ΣΥΣΚΕΥΗ ΠΡΟΣΤΑΣΙΑΣ ΑΠΟ ΥΠΕΡΤΑΣΕΙΣSPD
DIGITAL ALARM COMMUNICATOR TRANSMITTER
ΨΗΦΙΑΚΟΣ ΠΟΜΠΟΣ ΔΙΑΒΙΒΑΣΗΣ ΣΥΝΑΓΕΡΜΟΥ
DACT
THE FINAL QUANTITY AND LOCATION OF ALL DEVICES IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DEVICE QUANTITY AND LAYOUT MUST BE IN ACCORDANCE WITH ALL SPECIFICATIONS, CONTRACT DRAWINGS AND MANUFACTURER'S RECOMMENDATIONS, AND BE IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. PROVIDE ADDITIONAL DEVICES AS NECESSARY FOR A FULLY FUNCTIONING SYSTEM. REFER TO SHEET FA602 FOR AUDIBILITY, INTELLIGIBILITY, AND DEVICE MOUNTING GUIDANCE.
Η ΤΕΛΙΚΗ ΠΟΣΟΤΗΤΑ ΚΑΙ ΘΕΣΗ ΟΛΩΝ ΤΩΝ ΣΥΣΚΕΥΩΝ ΕΙΝΑΙ ΑΠΟΚΛΕΙΣΤΙΚΗ ΕΥΘΥΝΗ ΤΟΥ ΕΡΓΟΛΑΒΟΥ. Η ΠΟΣΟΤΗΤΑ ΚΑΙ ΧΩΡΟΘΕΤΗΣΗ ΤΩΝ ΣΥΣΚΕΥΩΝ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΟΛΕΣ ΤΙΣ ΠΡΟΔΙΑΓΡΑΦΕΣ, ΤΑ ΣΧΕΔΙΑ ΤΟΥ ΣΥΜΒΟΛΑΙΟΥ ΚΑΙ ΤΙΣ ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ ΚΑΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΟΛΟΥΣ ΤΟΥΣ ΕΦΑΡΜΟΖΟΜΕΝΟΥΣ ΚΩΔΙΚΕΣ ΚΑΙ ΠΡΟΤΥΠΑ. ΠΑΡΕΧΕΤΕ ΕΠΙΠΡΟΣΘΕΤΕΣ ΣΥΣΚΕΥΕΣ ΕΑΝ ΧΡΕΙΑΖΕΤΑΙ ΓΙΑ ΕΝΑ ΠΛΗΡΩΣ ΛΕΙΤΟΥΡΓΙΚΟ ΣΥΣΤΗΜΑ. ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ FA602 ΓΙΑ ΤΑ ΗΧΗΤΙΚΑ, ΤΗΝ
ΚΑΤΑΛΗΠΤΟΤΗΤΑ ΚΑΙ ΟΔΗΓΙΕΣ ΣΤΗΡΙΞΗΣ ΤΩΝ ΣΥΣΚΕΥΩΝ.
11.
CST
RPS NOTIFICATION APPLIANCE REMOTE POWER SUPPLY
ΑΠΟΜΑΚΡΥΣΜΕΝΗ ΠΑΡΟΧΗ ΣΥΣΚΕΥΗΣ ΕΙΔΟΠΟΙΗΣΕΩΝ
SYMBOL
ΣΥΜΒΟΛΟ
DESCRIPTION
ΠΕΡΙΓΡΑΦΗ
CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION
SPEAKER
ΜΕΓΑΦΩΝΟ ΕΙΔΟΠΟΙΗΣΗΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΣΤΗΡΙΖΟΜΕΝΟ
ΣΤΗΝ ΟΡΟΦΗ
CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION
SPEAKER/STROBE
ΦΑΡΟΣΕΙΡΗΝΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΤΟΠΟΘΕΤΗΜΕΝΗ
ΣΤΗΝ ΟΡΟΦΗ
CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION
STROBE
ΦΑΡΟΣ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ ΤΟΠΟΘΕΤΗΜΕΝΗ ΣΤΗΝ ΟΡΟΦΗ
WALL-MOUNTED FIRE ALARM/MASS
NOTIFICATION SPEAKER
ΕΠΙΤΟΙΧΟ ΜΕΓΑΦΩΝΟ ΣΥΣΤΗΜΑΤΟΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
WALL-MOUNTED FIRE ALARM/MASS
NOTIFICATION SPEAKER/STROBE
ΕΠΙΤΟΙΧΗ ΦΑΡΟΣΕΙΡΗΝΑ ΣΥΣΤΗΜΑΤΟ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
WALL-MOUNTED FIRE ALARM/MASS
NOTIFICATION STROBE
ΕΠΙΤΟΙΧΟΣ ΦΑΡΟΣ ΣΥΣΤΗΜΑΤΟΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ / ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:5
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA001
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
LE
G
EN
D
14089253
ΥΠ
Ο
Μ Ν
Η Μ
Α
ΣΥ
ΣΤ
Η
Μ Α
ΤΟ
Σ
ΣΥ
Ν
Α
ΓΕ
Ρ Μ
Ο Υ
Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ
DPS
DPS
F F
F
F
F
F
F
FM
C
P
MNTRPS AMP
F
F
MECH
UPS
ELEC
IT
LOGISTICS
BREAK
RECYCLE
DEMARC
STAIR 2
N6
N6 C3P
N6 ISSM
FIRE
PROT
RECEIVING
BUNK
QUARTER
DECK
N6
MAINTENANCE
STAIR 1
LOBBY
ELEV
N6
EQUIPMENT
ROOM
UPS
MENS
N6 CONF
CORRIDOR
NIPR
CAFE
WOMENS
CORRIDOR
N6 ID
IMIM
IM IM
S
S
S
S
VEST
VEST
107TX
T
TX
T
TX
T
K
JAN
IM
IM IM
IM
IM
IM
6 6
N6 MAINT
N6 STOR
MOTHERS
DEMARC
SIPR
CAFE
TR G-1
CLOSET
IM IM
IM
IM
IM
SB
WP
WP
WP
WP
IM IM
IM IM IM IM IM IM IM IM7
IM IM7
IM
IM
IM
IM
IM
IM5
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IMIMIM
IM
IM
IM
CM
12 12
IM
IM
IM IM IM
IM
IM
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:0
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA101
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
PL
AN
-G R
O U
N D
FL
O
O R
14089254
ΣΥ
ΣΤ
Η Μ
Α
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
ΚΑ
ΓΙ
Α
Σ -Ι
ΣΟ
ΓΕ
ΙΟ
DPS
DPS
1 : 100A1
FIRE ALARM PLAN - GROUND FLOOR
ΣΧΕΔΙΟ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ - ΙΣΟΓΕΙΟ
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND
CEILING GRIDS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΧΕΔΙΑ ΑΝΕΣΤΡΑΜΕΝΗΣ
ΟΡΟΦΗΣ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΑ ΦΩΤΑ, ΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΤΟΜΙΑ
ΚΑΙ ΤΟN KANABO ΤΗΣ ΟΡΟΦΗΣ.
C. REFER TO SHEET FA602 FOR ACOUSTICALLY DISTINGUISHABLE
SPACE SCHEDULE WITH MINIMUM SPL (dBA) AND INTELLIGIBILITY
(CIS) REQUIREMENTS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ FA602 ΓΙΑ ΤΟΝ ΠΙΝΑΚΑ ΜΕ ΤΑ ΔΙΑΚΡΙΤΑ
ΑΚΟΥΣΤΙΚΑ ΣΗΜΑΤΑ ΑΝΑ ΧΩΡΟ ΜΕ ΤΑ ΕΛΑΧΙΣΤ SPL (dBA) ΚΑΙ ΤΙΣ
ΑΠΑΙΤΗΣΕΙΣ ΚΑΤΑΛΗΠΤΟΤΗΤΑΣ (CIS)
D. REFER TO FP DRAWINGS FOR CLEAN AGENT FIRE ALARM DEVICES.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ ΤΗΣ ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
1 WEATHERPROOF EXTERIOR MASS NOTIFICATION SYSTEM LOUD
SPEAKERS ADJACENT TO BUILDING EXITS OR NEAR OUTSIDE
AREAS COMMONLY USED BY BUILDING OCCUPANTS SUCH THAT
SPEAKERS PROVIDE A MINIMUM CIS SCORE OF 0.70 AT 16 FEET
FROM THE SPEAKER.
ΑΔΙΑΒΡΟΧΑ ΕΞΩΤΕΡΙΚΑ ΜΕΓΑΦΩΝΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ ΠΑΡΑΚΕΙΜΕΝΑ ΣΤΙΣ ΕΞΟΔΟΥΣ ΤΟΥ ΚΤΗΡΙΟΥ Ή
ΚΟΝΤΑ ΣΕ ΕΞΩΤΕΡΙΚΟΥΣ ΧΩΡΟΥΣ ΠΟΥ ΧΡΗΣΙΜΟΠΟΙΟΥΝΤΑΙ
ΣΗΝΥΘΩΣ ΑΠΟ ΤΟΥΣ ΧΡΗΣΤΕΣ ΤΟΥ ΚΤΗΡΙΟΥ ΕΤΣΙ ΩΣΤΕ ΤΑ
ΜΕΓΑΦΩΝΑ ΝΑ ΠΑΡΕΧΟΥΝ CIS ΑΠΟΤΕΛΕΣΜΑ ΤΩΝ 0,70 ΣΤΑ 16
ΠΟΛΙΑ ΑΠΟ ΤΟ ΜΕΓΑΦΩΝΟ
2 PROVIDE CONTROL MODULES FOR THE SUPERVISION AND SHUT
DOWN OF DEDICATED IN ROOM CRAC UNTIS. CRAC UNITS HAVE
AN INTEGRAL SMOKE DETECTOR AND DO NOT NEED ONE
PROVIDED BY THE BUILDING.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΤΗΝ ΕΠΟΠΤΕΙΑ ΚΑΙ ΤΗΝ
ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ ΑΠΟΚΛΕΙΣΤΙΚΩΝ ΚΛΙΜΑΤΙΣΤΙΚΩΝ
ΜΟΝΑΔΩΝ ΤΟΥ ΧΩΡΟΥ ΥΠΟΛΟΓΙΣΤΩΝ. ΟΙ ΚΛΙΜΑΤΙΣΤΙΚΕΣ
ΜΟΝΑΔΕΣ ΧΩΡΟΥ ΥΠΟΛΟΓΙΣΤΩΝ ΕΧΟΥΝ ΕΝΣΩΜΑΤΩΜΕΝΟ
ΑΝΙΧΝΕΥΤΗ ΚΑΠΝΟΥ ΚΑΙ ΔΕΝ ΧΡΕΙΑΖΟΝΤΑΙ ΕΝΑΝ ΠΑΡΕΧΟΜΕΝΟ
ΑΠΟ ΤΟ ΚΤΗΡΙΟ.
3 SMOKE DETECTOR FOR PROTECTION OF CONTROL PANEL IN
ACCORDANCE WITH NFPA 72.
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΓΙΑ ΤΗΝ ΠΡΟΣΤΑΣΙΑ ΤΟΥ ΠΙΝΑΚΑ ΕΛΕΓΧΟΥ
ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 72.
4 SUPERVISORY KNOX BOX FOR FIRE DEPARTMENT ACCESS WITH
TAMPER SWITCH.
ΚΟΥΤΙ ΚΛΕΙΔΟΘΗΚΗΣ ΜΕ ΕΠΟΠΤΙΚΟ ΣΗΜΑ ΓΙΑ ΤΗΝ ΠΡΟΣΒΑΣΗ
ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ ΜΕ ΔΙΑΚΟΠΤΗ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ.
5 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY, AND
TROUBLE SIGNALS OF CLEAN AGENT RELEASING PANEL AND AIR
ASPIRATING DETECTION PANEL(S).
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ ΠΙΝΑΚΑ
(ΠΙΝΑΚΩΝ) ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ ΑΝΑΡΡΟΦΗΣΗ
ΑΕΡΑ.
6 PROVIDE SMOKE DETECTION OUTSIDE OF ELEVATOR DOOR.
ΠΑΡΕΧΕΤΕ ΑΝΙΧΝΕΥΣΗ ΚΑΠΝΟΥ ΕΞΩ ΑΠΟ ΤΗΝ ΠΟΡΤΑ ΤΟΥ
ΑΝΕΛΚΥΣΤΗΡΑ.
7 MONITOR TAMPER AND FLOW SWITCHES PROVIDED FOR
DEDICATED SPRINKLER CONTROL ZONES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΚΑΙ ΔΙΑΚΟΠΤΩΝ
ΡΟΗΣ ΠΟΥ ΠΑΡΕΧΟΝΤΑΙ ΑΠΟΚΛΕΙΣΤΙΚΑ ΓΙΑ ΤΙΣ ΖΩΝΕΣ ΕΛΕΓΧΟΥ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ.
8 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY, AND
TROUBLE SIGNALS OF AIR ASPIRATING SMOKE DETECTION
SYSTEM BENEATH RAISED FLOOR AS A SEPARATE ZONE.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ
ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ ΚΑΤΩ ΑΠΟ ΤΟ
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΣΑΝ ΞΕΧΩΡΙΣΤΗ ΖΩΝΗ.
9 COMBINATION FIRE ALARM/MASS NOTIFICATION PANEL WITH
INTEGRAL DACT.
ΠΙΝΑΚΑΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΙ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΜΕ
ΕΝΣΩΜΑΤΟΜΕΝΟ DACT
10 PROVIDE CONTROL MODULE FOR LIGHTING CONTACTOR TO
ACTIVATE MEANS OF EGRESS LIGHTING.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΓΙΑ ΤΟΝ ΕΡΓΟΛΑΒΟ ΤΟΥ ΦΩΤΙΣΜΟΥ
ΓΙΑ ΝΑ ΕΝΕΡΓΟΠΟΙΕΙ ΤΟ ΦΩΤΙΣΜΟ ΤΩΝ ΟΔΕΥΣΕΩΝ ΔΙΑΦΥΓΗΣ.
11 OMNI-DIRECTIONAL MASS NOTIFICATION SYSTEM ANTENNA.
ΠΑΝ-ΔΙΕΥΘΥΝΤΙΚΗ ΚΕΡΑΙΑ ΣΥΣΤΗΜΑΤΟΣ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ.
12 AREA PROTECTED BY CLEAN AGENT FIRE SUPPRESSION SYSTEM.
REFER TO FIRE PROTECTION DRAWINGS FOR CLEAN AGENT
DEVICES.
ΧΩΡΟΣ ΠΡΟΣΤΑΤΕΥΟΜΕΝΟΣ ΑΠΟ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΕΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ
ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ.
13 LED TEXT SIGNS FOR ANNUNCIATION OF FIRE ALARM/MASS
NOTIFICATION MESSAGES.
ΠΙΝΑΚΙΔΕΣ LED ΚΕΙΜΕΝΟΥ ΓΙΑ ΤΗΝ ΑΝΑΚΟΙΝΩΣΗ ΜΗΝΥΜΑΤΩΝ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ.
PLAN NORTH
0 100 200
SCALE 1 : 100
F F
AMP RPS
MECH
STAIR 2
N00
COMMAND
SEC
MNGR
NETWORK
DIST
AREA
N9
MAINTENANCE
TR 1-1
A
B
D
1 2 3 4 5 6 7 98
MENS
WOMENS
BREAK
JAN
UNCLASS
CONF
STAIR 1
ELEV
LNSC
ANALYSIS
LNSC DIR
ELEC
FIN ANLS
SN
ENLIST
TECH DIR
N3 LNSC
TX
T
TX
T
2IMIM
N9 OPEN
OFFICE
N9 BCO
AHU-01
STORAGE
IM
IM
IM
IM
IM
IM
IMIMIM
IMIMIM
IMIMIMIM
4 44 2
CORRIDOR
C
ST
IMIMIM
IM
IM
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:1
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA102
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
PL
AN
-F
IR
ST
FL
O O
R
14089255
ΣΥ
ΣΤ
Η Μ
Α
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ -Π
Ρ Ω
ΤΟ
Σ
Ο Ρ
Ο Φ
Ο Σ
DPS
DPS
1 : 100A1
FIRE ALARM PLAN - FIRST FLOOR
ΣΧΕΔΙΟ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ - ΠΡΩΤΟΣ ΟΡΟΦΟΣ
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND
CEILING GRIDS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΧΕΔΙΑ ΑΝΕΣΤΡΑΜΕΝΗΣ
ΟΡΟΦΗΣ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΑ ΦΩΤΑ, ΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΤΟΜΙΑ
ΚΑΙ ΤΟN KANABO ΤΗΣ ΟΡΟΦΗΣ.
C. REFER TO SHEET FA602 FOR ACOUSTICALLY DISTINGUISHABLE
SPACE SCHEDULE WITH MINIMUM SPL (dBA) AND INTELLIGIBILITY
(CIS) REQUIREMENTS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ FA602 ΓΙΑ ΤΟΝ ΠΙΝΑΚΑ ΜΕ ΤΑ ΔΙΑΚΡΙΤΑ
ΑΚΟΥΣΤΙΚΑ ΣΗΜΑΤΑ ΑΝΑ ΧΩΡΟ ΜΕ ΤΑ ΕΛΑΧΙΣΤ SPL (dBA) ΚΑΙ ΤΙΣ
ΑΠΑΙΤΗΣΕΙΣ ΚΑΤΑΛΗΠΤΟΤΗΤΑΣ (CIS)
D. REFER TO FP DRAWINGS FOR CLEAN AGENT FIRE ALARM DEVICES.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ ΤΗΣ ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
1 PROVIDE WATER FLOW AND TAMPER SWITCH AND
ADDRESSABLE INPUT MODULES FOR SPRINKLER BRANCE LINE
SERVING UPS AND ELECTRICAL ROOM.
ΠΑΡΕΧΕΤΕ ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ ΚΑΙ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΚΑΙ
ΔΙΕΥΘΥΝΣΙΟΔΟΤΟΥΜΕΝΕΣ ΜΟΝΑΔΕΣ ΕΙΣΟΔΟΥ ΓΙΑ ΤΗ ΓΡΑΜΜΗ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΟΥ ΕΞΥΠΗΡΕΤΕΙ ΤΟ UPS ΚΑΙ ΤΟ
ΗΛΕΚΤΡΟΣΤΑΣΙΟ.
2 LED TEXT SIGNS FOR ANNUNCIATION OF FIRE ALARM/MASS
NOTIFICATION MESSAGES.
ΠΙΝΑΚΙΔΕΣ LED ΚΕΙΜΕΝΟΥ ΓΙΑ ΤΗΝ ΑΝΑΚΟΙΝΩΣΗ ΜΗΝΥΜΑΤΩΝ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ.
3 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY, AND
TROUBLE SIGNALS OF CLEAN AGENT RELEASING PANEL AND AIR
ASPIRATING DETECTION PANEL(S).
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ ΠΙΝΑΚΑ
(ΠΙΝΑΚΩΝ) ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ ΑΝΑΡΡΟΦΗΣΗ
ΑΕΡΑ.
4 MONITOR TAMPER AND FLOW SWITCHES PROVIDED FOR
DEDICATED SPRINKLER CONTROL ZONES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΚΑΙ ΔΙΑΚΟΠΤΩΝ
ΡΟΗΣ ΠΟΥ ΠΑΡΕΧΟΝΤΑΙ ΑΠΟΚΛΕΙΣΤΙΚΑ ΓΙΑ ΤΙΣ ΖΩΝΕΣ ΕΛΕΓΧΟΥ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ.
5 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY, AND
TROUBLE SIGNALS OF AIR ASPIRATING SMOKE DETECTION
SYSTEM BENEATH RAISED FLOOR AS A SEPARATE ZONE.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ ΚΑΤΩ
ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΣΑΝ ΞΕΧΩΡΙΣΤΗ ΖΩΝΗ.
6 TWO-WAY EMERGENCY COMMUNICATIONS CALL STATION WITH
INSTRUCTIONAL SIGNAGE.
ΔΙΟΔΟΣ ΣΤΑΘΜΟΣ ΚΛΗΣΕΩΝ ΕΠΙΚΟΙΝΩΙΩΝ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ.
7 PROVIDE AIR ASPIRATING SMOKE DETECTION SYSTEM WITHIN
AND THROUGHOUT THE SPACE INCLUDING AREA BENEATH
RAISED ACCESS FLOORING.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ
ΜΕΣΑ ΚΑΙ ΣΕ ΟΛΟΚΛΗΡΟ ΤΟ ΧΩΡΟ ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΚΑΙ
ΤΟΥ ΧΩΡΟΥ ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ.
8 PROVIDE AIR APSIRATING SMOKE DETECTION SYSTEM
THROUGHOUT THE SPACE.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΣΕ ΟΛΟ ΤΟΝ ΧΩΡΟ.
9 AREA PROTECTED BY CLEAN AGENT FIRE SUPPRESSION
SYSTEM. REFER TO FIRE PROTECTION DRAWINGS FOR CLEAN
AGENT DEVICES.
ΧΩΡΟΣ ΠΡΟΣΤΑΤΕΥΟΜΕΝΟΣ ΑΠΟ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΕΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ
ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ.
0 100 200
PLAN NORTH
F F
RPS
AN
N
LO
C
AMP
TR 2-1
FLEET
CYBER -
EQUIP
N9 TECH
CONTROL
CLASSIFIED
CONFERENCE
ELEV
CORRIDOR
N00
STOR
N00C KMI
ELEC
MECH
STAIR 2
STAIR 1
FLEET
CYBER -
SECURE
A
B
C
D
1 2 3 4 5 6 7 98
KMI STOR
ISSM
COMM
SECURITY
MATERIAL
AREA
BREAK
MENS
WOMENS
JAN
TX
T
TX
T1
N3 STOR
IMIM
IMIM
IMIM
IM
IM
IM
3 3
SSO
OFFICE
N9
EQUIPMENT
ROOM
WATCH
CENTER
WATCH
CMDR
FLEET
CYBER -
CONF
NOO
340VESTIBULE
IMIM
IM
IM
IM 5
IM
IM
IM
IM
IM
IM
STORAGE
IM
IM
IM
IM
IM
IM
C
ST
ECCU
VEST
9 10
IM
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:2
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA103
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
PL
AN
-S
EC
O N
D
FL
O O
R
14089256
ΣΥ
ΣΤ
Η Μ
Α
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
ΚΑ
ΓΙ
Α
Σ -Δ
Ε
ΥΤ
Ε
ΡΟ
Σ Ο
Ρ Ο
Φ Ο
Σ
DPS
DPS
1 : 100A1
FIRE ALARM PLAN - SECOND FLOOR
ΣΧΕΔΙΟ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ - ΔΕΥΤΕΡΟΣ ΟΡΟΦΟΣ
1 LED TEXT SIGNS FOR ANNUNCIATION OF FIRE ALARM/MASS
NOTIFICATION MESSAGES.
ΠΙΝΑΚΙΔΕΣ LED ΚΕΙΜΕΝΟΥ ΓΙΑ ΤΗΝ ΑΝΑΚΟΙΝΩΣΗ
ΜΗΝΥΜΑΤΩΝ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ.
2 PROVIDE SMOKE DETECTION OUTSIDE OF ELEVATOR DOOR.
ΠΑΡΕΧΕΤΕ ΑΝΙΧΝΕΥΣΗ ΚΑΠΝΟΥ ΕΞΩ ΑΠΟ ΤΗΝ ΠΟΡΤΑ ΤΟΥ
ΑΝΕΛΚΥΣΤΗΡΑ.
3 MONITOR TAMPER AND FLOW SWITCHES PROVIDED FOR
DEDICATED SPRINKLER CONTROL ZONES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΚΑΙ
ΔΙΑΚΟΠΤΩΝ ΡΟΗΣ ΠΟΥ ΠΑΡΕΧΟΝΤΑΙ ΑΠΟΚΛΕΙΣΤΙΚΑ ΓΙΑ ΤΙΣ
ΖΩΝΕΣ ΕΛΕΓΧΟΥ ΚΑΤΑΙΟΝΗΤΗΡΩΝ.
4 MONITOR SUPERVISED SHUT-OFF VALVE AND WATERFLOW
SWITCH IN PIPING TO ELEVATOR MACHINE ROOM.
ACTUATION OF WATERFLOW SWITCH MUST REMOVE POWER
TO THE ELEVATOR VIA DIRECT CONNECTION FROM THE
WATERFLOW SWITCH TO SHUNT TRIP BREAKER.
WATERFLOW SWITCH MUST HAVE NO TIME DELAY
CAPABILITY. COORDINATE LOCATION OF VALVE WITH
ACCESS CEILING TILE.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΤΗΣ ΕΠΟΠΤΟΥΜΕΝΗΣ ΒΑΝΑΣ
ΚΛΕΙΣΙΜΑΤΟΣ ΚΑΙ ΤΟΥ ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ ΣΤΗ
ΣΩΛΗΝΩΣΗ ΣΤΙΣ ΣΩΛΗΝΩΣΕΙΣ ΤΟΥ ΜΗΧΑΝΟΣΤΑΣΙΟΥ ΤΟΥ
ΑΝΕΛΚΥΣΤΗΡΑ. Η ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΟΥ ΔΙΑΚΟΠΤΗ ΡΟΗΣ
ΝΕΡΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΚΟΠΤΕΙ ΤΗΝ ΠΑΡΟΧΗ ΣΤΟΝ
ΑΝΕΛΕΚΥΣΤΗΡΑ ΜΕΣΩ ΑΜΕΣΗΣ ΣΥΝΔΕΣΗΣ ΑΠΟ ΤΟ
ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ ΣΤΟΝ ΔΙΑΚΟΠΤΗ ΤΟΥ ΑΝΕΛΚΥΣΤΗΡΑ.
Ο ΔΙΑΚΟΠΤΗΣ ΡΟΗΣ ΝΕΡΟΥ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΕΧΕΙ
ΧΡΟΝΟΚΑΘΥΣΤΕΡΗΣΗ. ΣΥΝΤΟΝΙΣΤΕ ΤΗ ΘΕΣΗ ΤΗΣ ΒΑΝΑΣ ΜΕ
ΘΥΡΙΔΑ ΕΠΙΣΚΕΨΗΣ ΣΤΗΝ ΨΕΥΔΟΡΟΦΗ.
5 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY,
AND TROUBLE SIGNALS OF CLEAN AGENT RELEASING PANEL
AND AIR ASPIRATING DETECTION PANEL(S).
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ ΠΙΝΑΚΑ
(ΠΙΝΑΚΩΝ) ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ
ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ.
6 PROVIDE MONITOR MODULES FOR ALARM, SUPERVISORY,
AND TROUBLE SIGNALS OF AIR ASPIRATING SMOKE
DETECTION SYSTEM BENEATH RAISED FLOOR AS A
SEPARATE ZONE.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΣΗΜΑΤΑ
ΣΥΝΑΓΕΡΜΟΥ, ΕΠΟΠΤΕΙΑΣ ΚΑΙ ΠΡΟΒΛΗΜΑΤΩΝ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ
ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΣΑΝ ΞΕΧΩΡΙΣΤΗ
ΖΩΝΗ.
7 TWO-WAY EMERGENCY COMMUNICATIONS CONTROL UNIT.
ΔΙΟΔΗ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΕΠΙΚΟΙΝΩΝΙΩΝ ΕΚΤΑΚΤΗΣ
ΑΝΑΓΚΗΣ.
8 TWO-WAY EMERGENCY COMMUNICATIONS CALL STATION
WITH INSTRUCTIONAL SIGNAGE.
ΔΙΟΔΟΣ ΣΤΑΘΜΟΣ ΚΛΗΣΕΩΝ ΕΠΙΚΟΙΝΩΙΩΝ ΕΚΤΑΚΤΗΣ
ΑΝΑΓΚΗΣ.
9 AREA PROTECTED BY CLEAN AGENT FIRE SUPPRESSION
SYSTEM. REFER TO FIRE PROTECTION DRAWINGS FOR
CLEAN AGENT DEVICES.
ΧΩΡΟΣ ΠΡΟΣΤΑΤΕΥΟΜΕΝΟΣ ΑΠΟ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ
ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ.
10 PROVIDE AIR ASPIRATING SMOKE DETECTION SYSTEM
WITHIN AND THROUGHOUT THE SPACE INCLUDING AREA
BENEATH RAISED ACCESS FLOORING.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ
ΑΕΡΑ ΜΕΣΑ ΚΑΙ ΣΕ ΟΛΟΚΛΗΡΟ ΤΟ ΧΩΡΟ
ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΚΑΙ ΤΟΥ ΧΩΡΟΥ ΚΑΤΩ ΑΠΟ ΤΟ
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ.
11 PROVIDE SMOKE DETECTOR IN ELEVATOR PENTHOUSE
CONTROL ROOM.
ΠΑΡΕΧΕΤΕ ΑΝΙΧΝΕΥΤΗ ΚΑΠΝΟΥ ΣΤΟ ΔΩΜΑΤΙΟ ΕΛΕΓΧΟΥ
ΑΝΕΛΚΥΣΤΗΡΑ ΣΤΟΝ ΤΕΛΕΥΤΑΙΟ ΟΡΟΦΟ.
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND
CEILING GRIDS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΧΕΔΙΑ ΑΝΕΣΤΡΑΜΕΝΗΣ
ΟΡΟΦΗΣ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΑ ΦΩΤΑ, ΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΤΟΜΙΑ
ΚΑΙ ΤΟN KANABO ΤΗΣ ΟΡΟΦΗΣ.
C. REFER TO SHEET FA602 FOR ACOUSTICALLY DISTINGUISHABLE
SPACE SCHEDULE WITH MINIMUM SPL (dBA) AND INTELLIGIBILITY
(CIS) REQUIREMENTS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ FA602 ΓΙΑ ΤΟΝ ΠΙΝΑΚΑ ΜΕ ΤΑ ΔΙΑΚΡΙΤΑ
ΑΚΟΥΣΤΙΚΑ ΣΗΜΑΤΑ ΑΝΑ ΧΩΡΟ ΜΕ ΤΑ ΕΛΑΧΙΣΤ SPL (dBA) ΚΑΙ ΤΙΣ
ΑΠΑΙΤΗΣΕΙΣ ΚΑΤΑΛΗΠΤΟΤΗΤΑΣ (CIS)
D. REFER TO FP DRAWINGS FOR CLEAN AGENT FIRE ALARM DEVICES.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ ΤΗΣ ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
0 100 200
PLAN NORTH
B
FIMIM IM
CO
IM
GENERATOR
IM IM
IM
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:2
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA414
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
G
EN
ER
AT
O R
EN
C
LO
SU
R E
-F
IR
E
AL
AR
M
PL
AN
14089257
Χ Ω
ΡΟ
Σ
ΓΕ
Ν
Ν Η
ΤΡ
ΙΑ
Σ -Σ
Χ Ε
ΔΙ
Ο
ΣΥ
ΣΤ
Η Μ
ΑΤ
Ο
Σ
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ
DPS
DPS
1 : 20A1
GENERATOR ENCLOSURE FIRE ALARM
PLAN
ΣΧΕΔΙΟ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ ΧΩΡΟΥ ΓΕΝΝΗΤΡΙΑΣ
PLAN NORTH
0 10 20
SCALE 1 : 20
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
COORDINATION WITH LIGHTS, MECHANICAL DIFFUSERS, AND
CEILING GRIDS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΑΡΧΙΤΕΚΤΟΝΙΚΑ ΣΧΕΔΙΑ ΑΝΕΣΤΡΑΜΕΝΗΣ
ΟΡΟΦΗΣ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΑ ΦΩΤΑ, ΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΤΟΜΙΑ
ΚΑΙ ΤΟN KANABO ΤΗΣ ΟΡΟΦΗΣ.
C. REFER TO SHEET FA602 FOR ACOUSTICALLY DISTINGUISHABLE
SPACE SCHEDULE WITH MINIMUM SPL (dBA) AND INTELLIGIBILITY
(CIS) REQUIREMENTS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ FA602 ΓΙΑ ΤΟΝ ΠΙΝΑΚΑ ΜΕ ΤΑ ΔΙΑΚΡΙΤΑ
ΑΚΟΥΣΤΙΚΑ ΣΗΜΑΤΑ ΑΝΑ ΧΩΡΟ ΜΕ ΤΑ ΕΛΑΧΙΣΤ SPL (dBA) ΚΑΙ ΤΙΣ
ΑΠΑΙΤΗΣΕΙΣ ΚΑΤΑΛΗΠΤΟΤΗΤΑΣ (CIS)
D. REFER TO FP DRAWINGS FOR CLEAN AGENT FIRE ALARM DEVICES.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ ΤΗΣ ΠΥΡΑΣΦΑΛΕΙΑΣ ΓΙΑ ΤΙΣ ΣΥΣΚΕΥΕΣ
ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
1 MONITOR TAMPER AND FLOW SWITCHES FOR WET-PIPE FIRE
SPRINKLER SYSTEM.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΡΟΗΣ ΚΑΙ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΓΙΑ ΤΟ
ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΥΡΚΑΓΙΑΣ ΥΓΡΟΥ ΤΥΠΟΥ.
2 MONITOR TAMPER SWITCHES ON BACKFLOW PREVENTER.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΠΑΝΩ ΣΤΗΝ
ΑΝΤΕΠΙΣΤΡΟΦΗ.
3 FIRE ALARM DEVICES IN GENERATOR ENCLOSURE ARE AN
EXTENSION FROM THE FMCP LOCATED IN BUILDING P-131.
ΟΙ ΣΥΣΚΕΥΕΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΣΤΟΝ ΧΩΡΟ ΤΗΣ
ΓΕΝΝΗΤΡΙΑΣ ΕΙΝΑΙ ΕΠΕΚΤΑΣΗ ΑΠΟ ΤΟΝ FMCP ΠΟΥ ΒΡΙΣΚΕΤΑΙ ΣΤΟ
ΚΤΗΡΙΟ Ρ-131.
4 MONITOR MODULES SUPERVISING EMERGENCY GENERATOR
POWER.
ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΟΙ ΟΠΟΙΕΣ ΕΠΟΠΤΕΥΟΥΝ ΤΗΝ
ΠΑΡΟΧΗ ΤΗΣ ΓΕΝΝΗΤΡΙΑΣ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ.
SMOKE DETECTOR
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ
DROP CEILING TILE
ΠΛΑΚΑΚΙ ΨΕΥΔΟΡΟΦΗΣ
J-BOX ON FLOOR SLAB
ΚΟΥΤΙ ΔΙΑΚΛΑΔΩΣΗΣ
ΣΤΗΝ ΠΛΑΚΑ ΤΗΣ ΟΡΟΦΗΣ
J-BOX
ΚΟΥΤΙ ΔΙΑΚΛΑΔΩΣΗΣ
SMOKE DETECTOR BASE
ΒΑΣΗ ΑΝΙΧΝΕΥΤΗ ΚΑΠΝΟΥ
EMT CONDUIT
ΕΜΤ ΣΩΛΗΝΑΣ ΚΑΛΩΔΙΟΥ
"T" BAR TYPE HANGER
ΣΤΗΡΙΓΜΑ ΤΥΠΟΥ "Τ"
FLEX CONDUIT WITH FIRE WITH
FIRE DETECTION CIRCUITS
ΕΥΚΑΜΠΤΟΣ ΑΓΩΓΟΣ ΜΕ
ΚΥΚΛΩΜΑΤΑ ΑΝΙΧΝΕΥΣΗΣ
ΠΥΡΚΑΓΙΑΣ
J-BOX ON EXPOSED CEILING
ΚΟΥΤΙ ΕΝΩΣΗΣ ΣΤΗΝ ΕΚΤΕΘΕΙΜΕΝΗ ΟΡΟΦΗ
EMT CONDUIT
ΕΜΤ ΣΩΛΗΝΑΣ ΚΑΛΩΔΙΟΥ
SMOKE DETECTOR
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ
SMOKE DETECTOR BASE
ΒΑΣΗ ΑΝΙΧΝΕΥΤΗ
ΚΑΠΝΟΥ
FLOOR SLAB
ΠΛΑΚΑ ΟΡΟΦΗΣ
101.6 MM
(MIN)
914.4 MM
(MIN)
4.
M
M (M
AX
1.
M
M (M
IN
SUPPLY OR RETURN DIFFUSER
ΣΤΟΜΙΟ ΕΙΣΑΓΩΓΗΣ Ή
ΕΠΙΣΤΡΟΦΗΣ
CEILING LINE
ΓΡΑΜΜΗ ΟΡΟΦΗΣ
ACCEPTABLE HERE
ΑΠΟΔΕΚΤΟ ΕΔΩ
NEVER HERE
ΤΕ ΕΔΩ
WALL MOUNTED SMOKE
DETECTOR
ΕΠΙΤΟΙΧΟΣ ΑΝΙΧΝΕΥΤΗΣ
ΚΑΠΝΟΥ
FINISHED WALL
ΤΕΛΕΙΩΜΕΝΟΣ ΤΟΙΧΟΣ
1524 MM(MAX)
MANUAL PULL STATION
ΧΕΙΡΟΚΙΝΗΤΟΣ ΣΤΑΘΜΟΣ
ΕΛΞΗΣ
M M
TO
BO
TT
O
M O
F S
TR
O
BE
LE
N S, O R
2.
M
M
IN
BE
LO
W C
EI
LN
G
CEILING MOUNTED
SMOKE/HEAT DETECTOR
ΑΝΙΧΝΕΥΤΗΣ
ΚΑΠΝΟΥ/ΘΕΡΜΟΤΗΤΑΣ
ΤΟΠΟΘΕΤΗΜΕΝΟΣ ΣΤΗΝ
ΟΡΟΦΗ
M M
(O P
ER
AB
LE
PA
R T
O F
KE
Y)
CEILING MOUNTED NOTIFICATION APPLIANCE
(INSTALL AT BOTTOM OF JOIST OR BEAM IF OPEN AREA TO STRUCTURE)
ΣΥΣΚΕΥΗ ΕΙΔΟΠΟΙΗΣΕΩΝ ΤΟΠΟΘΕΤΗΜΕΝΗ ΣΤΗΝ ΟΡΟΦΗ
(ΕΓΚΑΤΑΣΤΑΣΗ ΣΤΟ ΚΑΤΩ ΜΕΡΟΣ ΤΟΥ ΔΟΚΑΡΙΟΥ ΕΑΝ ΥΠΑΡΧΕΙ ΑΝΟΙΚΤΟΣ
ΧΩΡΟΣ ΑΠΟ ΤΗΝ ΚΑΤΑΣΚΕΥΗ)
FINISHED WALL
ΤΕΛΕΙΩΜΕΝΟΣ ΤΟΙΧΟΣ
FINISHED FLOOR
FM
C
P
FIRE ALARM/MASS
NOTIFICATION
CONTROL PANEL
ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ
ΣΥΣΤΗΜΑΤΟΣ
ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ
M M
(M
AX
WALL MOUNTED NOTIFICATION APPLIANCE
ΕΠΙΤΟΙΧΗ ΣΥΣΚΕΥΗ ΕΙΔΟΠΟΙΗΣΕΩΝ
M M
(A
AS
D
PA
N
EL
SD-PH PROTECTIVE HOUSING
ΠΡΟΣΤΑΤΕΥΤΙΚΟ ΠΕΡΙΒΛΗΜΑ
SD-PH
REAR VIEW
ΠΛΑΪΝΗ ΟΨΗ
HINGED COVER
ΣΥΝΔΕΔΕΜΕΝΟ ΚΑΛΥΜΜΑ
DUCT DETECTOR
ΑΝΙΧΝΕΥΤΗΣ ΑΓΩΓΟΥ
DETECTOR CONDUIT HOLES
ΤΡΥΠΕΣ ΣΩΛΗΝΩΝ ΚΑΛΩΔΙΩΝ
ΑΝΙΧΝΕΥΤΗ
HOUSING AIR TUBE
ΠΕΡΙΒΛΗΜΑ ΣΩΛΗΝΑ
ΑΕΡΑ
HOUSING AIR TUBE
ΠΕΡΙΒΛΗΜΑ ΣΩΛΗΝΑ ΑΕΡΑ
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:2
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA501
MN ZSH TB
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
D
ET
AI
LS
14089258
Λ
ΕΠ
ΤΟ
Μ
Ε
ΡΕ
ΙΕ
Σ
ΣΥ
ΣΤ
Η Μ
ΑΤ
Ο
Σ
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ
DPS
DPS
NTSD1
SMOKE DETECTOR - DROP CEILING
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ - ΨΕΥΔΟΡΟΦΗ
N.T.S.C1
SMOKE DETECTOR - EXPOSED
STRUCTURE
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ - ΕΚΤΕΘΕΙΜΕΝΗ
ΚΑΤΑΣΚΕΥΗ
N.T.S.A1
DEVICE MOUNTING DETAIL
ΛΕΠΤΟΜΕΡΕΙΑ ΤΟΠΟΘΕΤΗΣΗΣ ΣΥΣΚΕΥΩΝ
1 : 1A3
DUCT SMOKE DETECTOR PROTECTIVE
HOUSING DETAIL
ΛΕΠΤΟΜΕΡΕΙΑ ΠΕΡΙΒΛΗΜΑΤΟΣ
ΑΝΙΧΝΕΥΤΗ ΚΑΠΝΟΥ ΑΕΡΑΓΩΓΟΥ
AC
TI
VA
TE
VI
SI
BL
E
AL
AR
M
IN
D
IC
AT
O
R
1 MANUAL FIRE ALARM PULL STATION
A
CONTROL UNIT ANNUNCIATION
ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΑΝΑΚΟΙΝΩΣΕΩΝ
NOTIFICATION
ΕΙΔΟΠΟΙΗΣΕΙΣ
CONTROL FUNCTIONS
ΛΕΙΤΟΥΡΓΙΕΣ ΕΛΕΓΧΟΥ
AC
TI
V
AT
E
AU
D
IB
LE
AL
AR
M
SI
G
N
AL
B
AC
TI
VA
TE
VI
SI
BL
E
SU
PE
R V
IS
O
R Y
IN
D
IC
AT
O R
C
AC
TI
VA
TE
AU
D
IB
LE
SU
PE
R
VI
SO
R
Y
SI
G N
AL
D
AC
TI
V
AT
E
AU
D
IB
LE
AN
D
VI
SI
BL
E
TR
O U
BL
E
IN
D
IC
AT
O R
E
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Ο
Π
ΤΙ
ΚΟ
/Α
ΚΟ
ΥΣ
ΤΙ
ΚΟ
Υ
ΔΕ
ΙΚ
ΤΗ
Π
ΡΟ
ΒΛ
Η
Μ Α
ΤΩ
Ν
D
IS
PL
AY
D
EV
IC
E
D
ES
C R
IP
TI
O N
AN
D
LO
C
AT
IO
N
SMOKE DETECTOR (PROTECTING FIRE ALARM PANELS)2
ELEVATOR MACHINE ROOM SMOKE DETECTOR3
ELEVATOR LOBBY SMOKE DETECTOR ON PRIMARY FLOOR4
ELEVATOR LOBBY SMOKE DETECTOR ON SECONDARY FLOOR5
SPRINKLER SYSTEM WATER FLOW SWITCH6
ELEVATOR MACHINE ROOM WATER FLOW SWITCH WITH ZERO TIME DELAY7
ALARM SIGNAL FROM CLEAN AGENT SYSTEM PANEL
ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΑΠΟ ΠΙΝΑΚΑ ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ8
ΣΗΜΑΤΑ ΣΥΝΑΓΕΡΜΟΥ
SUPERVISORY SIGNALS
VALVE TAMPER SWITCH10
DUCT SMOKE DETECTOR11
TR
AN
SM
IT
AL
AR
M
SI
G N
AL
TO
BA
S
E R
EC
EI
VI
N
G
ST
AT
IO
N
TR
A
N
SM
IT
SU
PE
R
V
IS
O R
Y
SI
G N
AL
TO
BA
SE
R
EC
EI
VI
N G
ST
AT
IO
N
TR
AN
SM
IT
TR
O
U
BL
E
SI
G N
AL
TO
BA
SE
R
EC
EI
VI
N G
ST
AT
IO
N
G H I
AC
TI
V
AT
E
VI
SU
A
L N
O
TI
FI
C
AT
IO
N
AP
PL
IA
N C
ES
AC
TI
V
AT
E
FI
R E
AL
AR
M
VO
IC
E
M
ES
SA
G
E
AC
TI
VA
TE
PR
E-
R E
C O
R D
ED
V
O
IC
E M
N S
D
IS
TR
IB
U
TE
M N
S M
ES
SA
G E
FR
O
M
BA
SE
-W
ID
E
M N
S
LE
D
TE
XT
U
AL
D
IS
PL
AY
O F
M
ES
SA
G
E
J K L M N
SYSTEM OUTPUTS / ΕΞΟΔΟΙ ΣΥΣΤΗΜΑΤΟΣ
SH
U
T D
O W
N
AS
S O
C
IA
TE
D
AI
R
-H A
N D
LI
N
G U
N
IT
R E
C
AL
L
EL
EV
A
TO
R
TO
PR
IM
AR
Y
FL
O O
R
R E
C
AL
L
EL
EV
A
TO
R
TO
SE
C O
N D
AR
Y
FL
O
O R
AC
TI
VA
TE
EL
EV
AT
O
R S
H U
N T
TR
IP
R
EL
AY
AC
TI
VA
TE
SO
LI
D
FI
R E
M
AN
'S H
AT
AC
TI
VA
TE
FL
AS
H
IM
G
FI
R E
M
AN
'S H
AT
O P Q R SALARM SIGNALS
12 FIRE DEPARTMENT RAPID ENTRY SYSTEM TAMPER SWITCH
MASS NOTIFICATION SYSTEM INPUT13
SUPERVISORY SIGNAL FROM CLEAN AGENT SYSTEM PANEL14
TROUBLE SIGNALS
AC POWER FAILURE
T
LOW BATTERY
OPEN CIRCUIT FAULT
GROUND FAULT
NOTIFCATION APPLIANCE CIRCUIT SHORT
TROUBLE SIGNAL FROM CLEAN AGENT SYSTEM PANEL
U
TR
AN
SM
IT
W
AT
ER
FL
O W
SI
G
N
AL
TO
BA
S E
R
EC
EI
VI
N G
ST
AT
IO
N
PANEL FUNCTIONS
SYSTEM SILENCE
SYSTEM RESET
SI
LE
N C
E N
O
TI
FI
C
A
TI
O N
A
PP
LI
AN
C
ES
V
C O
N
TR
O L
P
AN
EL
R
ET
U
R N
S
TO
N O
R M
AL
W
ΧΕΙΡΟΚΙΝΗΤΟΣ ΣΤΑΘΜΟΣ ΕΛΞΗΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ
ΑΝΙΧΝΕΥΤΗΣ ΚΑΝΠΝΟΥ (ΠΟΥ ΠΡΟΣΤΑΤΕΥΕΙ ΤΟΥΣ ΠΙΝΑΚΕΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ)
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΜΗΧΑΝΟΣΤΑΣΙΟΥ ΑΝΕΛΚΥΣΤΗΡΑ
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΠΡΟΘΑΛΑΜΟΥ ΑΝΕΛΚΥΣΤΗΡΑ ΣΤΟΝ ΠΡΩΤΟ ΟΡΟΦΟ
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΠΡΟΘΑΛΑΜΟΥ ΑΝΕΛΚΥΣΤΗΡΑ ΣΤΟ ΔΕΥΤΕΡΟ ΟΡΟΦΟ
ΔΙΑΚΟΠΤΗΣ ΡΟΗΣ ΝΕΡΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ
ΔΙΑΚΟΠΤΗΣ ΡΟΗΣ ΝΕΡΟΥ ΜΗΔΕΝΙΚΗΣ ΚΑΘΥΣΤΕΡΗΣΗΣ ΣΤΟ ΜΗΧ/ΣΙΟ ΑΝΕΛ/ΡΑ
ΕΠΟΠΤΙΚΑ ΣΗΜΑΤΑ
ΔΙΑΚΟΠΤΗΣ ΔΙΑΦΡΑΓΜΑΤΟΣ ΒΑΝΑΣ
ΑΝΙΧΝΕΥΤΗΣ ΚΑΠΝΟΥ ΑΕΡΑΓΩΓΟΥ
ΔΙΑΚΟΠΤΗΣ ΔΙΑΦΡΑΓΜΑΤΟΣ ΣΥΣΤΗΜΑΤΟΣ ΤΑΧΕΙΑΣ ΕΙΣΟΔΟΥ ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ
ΕΙΣΟΔΟΣ ΣΥΣΤΗΜΑΤΟΣ ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
ΣΗΜΑ ΕΠΙΒΛΕΨΗΣ ΑΠΟ ΠΙΝΑΚΑ ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
ΣΗΜΑΤΑ ΠΡΟΒΛΗΜΑΤΩΝ
ΑΠΟΤΥΧΙΑ AC ΠΑΡΟΧΗΣ
ΧΑΜΗΛΗ ΜΠΑΤΑΡΙΑ
ΣΦΑΛΜΑ ΑΝΟΙΚΤΟΥ ΚΥΚΛΩΜΑΤΟΣ
ΣΦΑΛΜΑ ΓΕΙΩΣΗΣ
ΕΙΔΟΠΟΙΗΣΗ ΒΡΑΧΥΚΥΚΛΩΜΕΝΗΣ ΣΥΣΚΕΥΗΣ
ΣΗΜΑ ΠΡΟΒΛΗΜΑΤΟΣ ΑΠΟ ΠΙΝΑΚΑ ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
ΛΕΙΤΟΥΡΓΙΕΣ ΠΙΝΑΚΑ
ΣΙΓΑΣΗ ΣΥΣΤΗΜΑΤΟΣ
ΕΠΑΝΑΦΟΡΑ ΣΥΣΤΗΜΑΤΟΣ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
ΔΕ
ΙΚ
ΤΗ
Ο
ΡΑ
ΤΟ
Υ
ΣΥ
Ν
ΑΓ
ΕΡ
Μ Ο
Υ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
ΣΗ
Μ
ΑΤ
Ο Σ
ΑΚ
Ο
Υ
ΣΤ
ΙΚ
Ο
Υ
ΣΥ
Ν
ΑΓ
ΕΡ
Μ
Ο Υ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Ο
ΡΑ
ΤΟ
Υ
ΕΠ
Ο Π
ΤΙ
ΚΟ
Υ
ΔΕ
ΙΚ
ΤΗ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Α
ΚΟ
Υ
ΣΤ
ΙΚ
Ο Υ
ΕΠ
Ο
Π
ΤΙ
ΚΟ
Υ
ΣΗ
Μ
ΑΤ
Ο
Σ
Π Α
ΡΟ
Υ
ΣΙ
Α
ΣΗ
Π
ΕΡ
ΙΓ
ΡΑ
Φ
Η
ΚΑ
ΙΘ
Ε
ΣΗ
ΣΥ
ΣΚ
ΕΥ
Η Σ
Μ
ΕΤ
ΑΔ
Ο
ΣΗ
ΣΗ
Μ
ΑΤ
Ο Σ
ΣΥ
Ν
Α
ΓΕ
ΡΜ
Ο
Υ
ΣΤ
Ο
ΣΤ
ΑΘ
Μ
Ο Λ
Η Ψ
Η Σ
ΒΑ
ΣΗ
Σ
Μ
ΕΤ
ΑΔ
Ο
ΣΗ
Ε
Π Ο
Π
ΤΙ
ΚΟ
Υ
ΣΗ
Μ
ΑΤ
Ο
Σ
ΣΤ
Ο
ΣΤ
Α Θ
Μ Ο
ΛΗ
Ψ
Η Σ
ΒΑ
ΣΗ
Σ
Μ
ΕΤ
ΑΔ
Ο
ΣΗ
ΣΗ
Μ
ΑΤ
Ο Σ
Π
ΡΟ
ΒΛ
Η
Μ
ΑΤ
Ο Σ
ΣΤ
Ο
ΣΤ
ΑΘ
Μ Ο
Λ Η
Ψ Η
Σ
ΒΑ
ΣΗ
Σ
Μ
ΕΤ
ΑΔ
Ο
ΣΗ
ΣΗ
Μ
ΑΤ
Ο Σ
ΡΟ
Η
Σ Ν
ΕΡ
Ο
Υ
ΣΤ
Ο
ΣΤ
ΑΘ
Μ
Ο
ΛΗ
Ψ Η
Σ
ΒΑ
ΣΗ
Σ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Ο
Π
ΤΙ
Κ Ω
Ν
ΣΥ
ΣΚ
Ε
ΥΩ
Ν
ΕΙ
ΔΟ
Π Ο
ΙΗ
ΣΕ
Ω Ν
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Η
ΧΗ
ΤΙ
ΚΟ
Υ
Μ Η
Ν Υ
Μ
ΑΤ
Ο Σ
ΣΥ
Ν
ΑΓ
ΕΡ
Μ Ο
Υ Π
Υ
ΡΚ
ΑΓ
ΙΑ
Σ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Π
ΡΟ
-Η
ΧΟ
ΓΡ
ΑΦ
Η
Μ
ΕΝ
Ο Υ
Η
ΧΗ
ΤΙ
ΚΟ
Υ M
N S
ΔΙ
ΑΝ
Ο Μ
Η Μ
Η Ν
ΥΜ
ΑΤ
Ο Σ
M N
S
ΑΠ
O
ΤΟ
M N
S Π
Ο Υ
ΕΚ
ΤΕ
ΙΝ
ΕΤ
ΑΙ
ΣΕ
Ο
ΛΗ
ΤΗ
ΒΑ
ΣΗ
LE
D
ΓΡ
Α
Φ
ΙΚ
Η Α
Π
ΕΙ
ΚΟ
Ν
ΙΣ
Η
ΤΟ
Υ
Μ Η
Ν
ΥΜ
ΑΤ
Ο
Σ
ΑΠ
ΕΝ
ΕΡ
ΓΟ
Π Ο
ΙΗ
ΣΗ
Σ
ΣΧ
ΕΤ
ΙΚ
Η Σ
ΚΛ
ΙΜ
ΑΤ
ΙΣ
ΤΙ
ΚΗ
Σ Μ
Ο Ν
ΑΔ
ΑΣ
ΕΠ
ΑΝ
ΑΦ
Ο
Ρ Α
ΑΝ
ΕΛ
ΚΥ
ΣΤ
Η Ρ
Α
ΣΤ
Ο Ν
Π
ΡΩ
ΤΟ
Ο
Ρ Ο
Φ Ο
ΑΠ
ΑΝ
ΑΦ
Ο
ΡΑ
ΑΝ
Ε
ΛΚ
ΥΣ
ΤΗ
ΡΑ
ΣΤ
Ο Δ
ΕΥ
ΤΕ
ΡΟ
Ο
Ρ Ο
Φ Ο
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Δ
ΙΑ
ΚΟ
Π
ΤΗ
ΡΕ
Λ
Ε
ΑΠ
Ο Μ
ΑΚ
ΡΥ
ΣΜ
ΕΝ
Η Σ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Σ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Φ
Ω
ΤΙ
ΣΤ
ΙΚ
Ο Υ
Μ Ε
Ε Ν
ΔΕ
ΙΞ
Η
ΚΡ
Α Ν
Ο Σ
Π
ΥΡ
Ο
ΣΒ
ΕΣ
ΤΗ
Μ Ε
ΣΤ
ΑΘ
ΕΡ
Ο
ΔΩ
ΤΙ
ΣΜ
Ο
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Φ
Ω
ΤΙ
ΣΤ
ΙΚ
Ο Υ
Μ Ε
Ε Ν
ΔΕ
ΙΞ
Η
ΚΡ
Α Ν
Ο Σ
Π
ΥΡ
Ο
ΣΒ
ΕΣ
ΤΗ
Μ Ε
Φ Ω
Σ Π
Ο Υ
ΑΝ
ΑΒ
Ο
ΣΒ
Η Ν
ΕΙ
ΣΙ
ΓΑ
ΣΗ
ΣΥ
ΣΚ
ΕΥ
Ω Ν
ΕΙ
ΔΟ
Π Ο
ΙΗ
ΣΕ
Ω Ν
ΕΠ
ΑΝ
ΑΦ
Ο
ΡΑ
Π
ΙΝ
ΑΚ
Α
ΕΛ
ΕΓ
ΧΟ
Υ
ΣΕ
ΚΑ
Ν
Ο Ν
ΙΚ
Η
ΛΕ
ΙΤ
Ο
ΥΡ
ΓΙ
Α
ΕΙΣΟΔΟΙ ΣΥΣΤΗΜΑΤΟΣ
SYSTEM INPUTS
F
GENERATOR RUNNING16 ΓΕΝΝΗΤΡΙΑ ΣΕ ΛΕΙΤΟΥΡΓΙΑ
GENERATOR FAULT
ΣΦΑΛΜΑ ΓΕΝΝΗΤΡΙΑΣ
GENERATOR IN NON-AUTOMATIC17 ΓΕΝΝΗΤΡΙΑ ΣΕ ΜΗ-ΑΥΤΟΜΑΤΟ
ALARM SIGNAL FROM GENERATOR BUILDING *
ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΑΠΟ ΚΤΗΡΙΟ ΓΕΝΝΗΤΡΙΑΣ *9
X
EN
ER
G
IZ
E
LI
G H
TS
W
IT
H
IN
TH
E M
EA
N
S O
F E
G R
ES
S
ΤΡ
Ο
Φ Ο
ΔΟ
ΣΙ
Α Φ
Ω
ΤΙ
ΣΤ
ΙΚ
Ω Ν
ΣΤ
ΙΣ
Ο
ΔΕ
ΥΣ
ΕΙ
Σ
ΔΙ
ΑΦ
ΥΓ
Η Σ
AASD PRE-ALERT SIGNAL
ΣΗΜΑ ΠΡΟ-ΣΥΝΑΓΕΡΜΟΥ AASD
NOTE: * ALARM SIGNAL FROM GENERATOR BUILDING SHOULD ACTIVATE DEVICES IN
GENERATOR BUILDING ONLY AND BE MONITORED BY THE FMCP IN THE COMMUNICATIONS
FACILITY.
ΣΗΜΕΙΩΣΗ: * ΤΟ ΣΗΜΑ ΣΥΝΑΓΕΡΜΟΥ ΑΠΟ ΤΟ ΚΤΗΡΙΟ ΤΗΣ ΓΕΝΝΗΤΡΙΑΣ ΘΑ ΠΡΕΠΕΙ ΝΑ
ΕΝΕΡΓΟΠΟΙΕΙ ΣΥΣΚΕΥΕΣ ΜΟΝΟ ΜΕΣΑ ΣΤΟ ΚΤΗΡΙΟ ΤΗΣ ΓΕΝΝΗΤΡΙΑΣ ΚΑΙ ΝΑ
ΠΑΡΑΚΟΛΟΥΘΕΙΤΑΙ ΑΠΟ ΤΟΝ FMCP ΣTHΝ ΕΓΚΑΤΑΣΤΑΣΗ ΤΩΝ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
EPO DISCONNECT FROM CLEAN AGENT RELEASING PANEL
ΑΠΟΣΥΝΔΕΣΗ EPO ΑΠΟ ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
SH
U
T D
O W
N
PO
W
ER
TO
EL
E C
TR
O
N
IC
EQ
U
IP
M
EN
T
IN
R
O O
M
IN
AL
AR
M
ΑΠ
ΕΝ
ΕΡ
ΓΟ
Π
Ο
ΙΗ
ΣΗ
Η
ΛΕ
ΚΤ
ΡΙ
ΚΗ
Σ Π
ΑΡ
Ο
ΧΗ
Σ
ΣΤ
Ο
Ν Η
ΛΕ
ΚΤ
ΡΟ
ΛΟ
ΓΙ
ΚΟ
ΕΞ
Ο
Π
ΛΙ
ΣΜ
Ο
ΣΤ
Ο
ΔΩ
Μ
ΑΤ
ΙΟ
ΣΕ
ΣΥ
Ν
ΑΓ
ΕΡ
Μ
Ο
Y
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:3
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA502
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
D
ET
AI
LS
14089259
Λ
ΕΠ
ΤΟ
Μ
Ε
ΡΕ
ΙΕ
Σ
ΣΥ
ΣΤ
Η Μ
ΑΤ
Ο
ΣΥ
Ν
Α
ΓΕ
Ρ Μ
Ο Υ
Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ
DPS
DPS
NTSA1
FA/MNS SYSTEM SEQUENCE OF OPERATIONS
ΑΚΟΥΛΟΥΘΙΑ ΛΕΙΤΟΥΡΓΙΑΣ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ
FMCP
BAT
M M
90 cm H x 61 cm W x 10 cm D
360.68 MM H x
459.7 MM W x
180.3 MM D
AASD
350.5 MM H x
228.6 MM W x
129.5 D
M M
M
M BAT
358.1 MM H x
459.7 MM W x
180.3 MM IN D
BAT
M M
355.6 MM H x
462.3 MM W x
182.8 D
CARP
(FIELD VERIFY
ACTUAL SIZE)
M M
(ΕΠΙΒΕΒΑΙΩΣΗ
ΠΡΑΓΜΑΤΙΚΟΥ
ΜΕΓΕΘΟΥΣ ΣΤΟ
ΠΕΔΙΟ)
FMCP
IM IMANN
1. REFER TO SHEET F-001 FOR GENERAL NOTES
AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ
ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ ΣΥΜΒΟΛΑ
2. RISER DIAGRAM IS A SCHEMATIC
REPRESENTATION OF THE FIRE ALARM/MASS
NOTIFICATION CONTROL PANEL, CLEAN AGENT
RELEASING PANEL, AND ASSOCIATED SYSTEMS.
ΤΟ ΚΑΤΑΚΟΡΥΦΟ ΔΙΑΓΡΑΜΜΑ ΕΙΝΑΙ ΜΙΑ
ΣΧΗΜΑΤΙΚΗ ΑΝΑΠΑΡΑΣΤΑΣΗ ΤΟΥ ΠΙΝΑΚΑ
ΕΛΕΓΧΟΥ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ, ΤΟΥ ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ
ΚΑΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΩΝ
ΣΧΕΤΙΚΩΝ ΣΥΣΤΗΜΑΤΩΝ.
SEE FIRE ALARM PLANS FOR PROPOSED
LOCATIONS OF INITIATING DEVICES.
ΒΛΕΠΕ ΣΧΕΔΙΑ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΓΙΑ
ΠΡΟΤΕΙΝΟΜΕΝΕΣ ΘΕΣΕΙΣ ΣΥΣΚΕΥΩΝ
ΕΝΕΡΓΟΠΟΙΗΣΗΣ.
PROVIDE 230 VAC, 16 AMP DEDICATED CIRCUIT
PROTECTED BY SURGE/LIGHTNING SUPPRESSORS FOR
NEW CLEAN AGENT RELEASING PANELS. PROVIDE
SEPARATE INDEPENDENT 230 VAC CIRCUIT FOR NEW
FMCP.
ΠΑΡΕΧEΤΕΕΙΔΙΚΟ ΚΥΚΛΩΜΑ 230 VAC, 16 AMP, ME
ΑΝΤΙΚΕΡΑΥΝΙΚΗ ΠΡΟΣΤΑΣΙΑ ΚΑΙ ΠΡΟΣΤΑΣΙΑ ΑΠΟ
ΥΠΕΡΤΑΣΕΙΣ ΓΙΑ ΤΟΥΣ ΝΕΟΥΣ ΠΙΝΑΚΕΣ ΑΠΕΛΕΥΘΕΡΩΣΗΣ
ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ. ΠΑΡΕΧΕΤΕ
ΞΕΧΩΡΙΣΤΟ ΑΝΕΞΑΡΤΗΤΟ 230VAC ΚΥΚΛΩΜΑ ΓΙΑ ΤΟ ΝΕΟ
FMCP.
PROVIDE GROUND PER NEC-NFPA 70
ΠΑΡΕΧΕΤΕ ΓΕΙΩΣΗ ΣΥΜΦΩΝΑ ΜΕ ΤΟ NEC-NFPA 70.
PROVIDE NOTIFICATION APPLIANCE AND SPEAKER
CIRCUITS AS REQUIRED SUCH THAT VOLTAGE DROP
DOES NOT EXCEED THE MAXIMUM ALLOWED BY THE
MANUFACTURER PER CIRCUIT. PROVIDE SPARE
CAPACITY PER 28 31 76.
ΠΑΡΕΧΕΤΕ ΚΥΚΛΩΜΑΤΑ ΗΧΕΙΩΝ ΚΑΙ ΣΥΣΚΕΥΩΝ
ΕΙΔΟΠΟΗΣΕΩΝ ΟΠΩΣ ΧΡΕΙΑΖΕΤΑΙ ΕΤΣΙ ΩΣΤΕ Η ΠΤΩΣΗ
ΤΑΣΗΣ ΝΑ ΜΗΝ ΞΕΠΕΡΝΑ ΤΗ ΜΕΓΙΣΤΗ ΕΠΙΤΡΕΠΟΜΕΝΗ
ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΑΝΑ ΚΥΚΛΩΜΑ. ΠΑΡΕΧΕΤΕ
ΕΦΕΔΡΙΚΗ ΔΥΝΑΤΟΤΗΤΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟ 28 31 76.
PROVIDE CLASS B SIGNALING LINE, INITIATING DEVICE,
AND NOTIFICATION APPLIANCE CIRCUITS.
ΠΑΡΕΧΕΤΕ ΓΡΑΜΜΗ ΣΗΜΑΝΣΗΣ ΚΛΑΣΗΣ Β, ΣΥΣΚΕΥΗ
ΕΝΑΡΞΗΣ ΚΑΙ ΚΥΚΛΩΜΑΤΑ ΣΥΣΚΕΥΩΝ ΕΙΔΟΠΟΙΗΣΕΩΝ.
GENERAL NOTES
ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ
NOTES BY SYMBOL
ΣΗΜΕΙΩΣΕΙΣ ΑΝΑ ΣΥΜΒΟΛΟ
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL.
(FMCP) SHALL BE SEAMLESSLY COMPATABLE WITH
BASE REPORTING SYSTEM IN FIRE DEPARTMENT
DISPATCH CENTER. PROVIDE FMCP WITH INTEGRAL
DACT.
Ο ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ/ΜΑΖΙΚΗΣ ΕΙΔΟΠΟΙΗΣΗΣ (FMCP) ΠΡΕΠΕΙ ΝΑ
ΕΙΝΑΙ ΑΠΟΛΥΤΩΣ ΣΥΜΒΑΤΟΣ ΜΕ ΤΟ ΣΥΣΤΗΜΑ
ΑΝΑΦΟΡΑΣ ΤΗΣ ΒΑΣΗΣ ΣΤΟ ΚΕΝΤΡΟ ΜΕΤΑΓΩΓΩΝ ΤΗΣ
ΠΥΡΟΣΒΕΣΤΙΚΗΣ ΥΠΗΡΕΣΙΑΣ. ΠΑΡΕΧΕΤΕ ΤΟΝ FMCP ΜΕ
ΕΝΣΩΜΑΤΩΜΕΝΟ DACT.
3.
PROVIDE DUCT SMOKE DETECTORS ON THE SUPPLY SIDE
OF ALL AIR HANDLING UNITS OVER 944 LPS AND RETURN
SIDE OF ALL AIR HANDLING UNITS OVER 7,079 LPS. UNITS
DEDICATED SOLEY TO SPACES WITH SMOKE DETECTION
THROUGHOUT ARE NOT REQUIRED TO BE PROVIDED
WITH DUCT TYPE DETECTION. AHU SHUT DOWN IN THESE
CASES SHALL BE INITIATED BY ACTIVATION OF
DETECTION IN COMPARTEMENT.
ΠΑΡΕΧΕΤΕ ΑΝΙΧΝΕΥΤΕΣ ΚΑΠΝΟΥ ΑΕΡΑΓΩΓΩΝ ΣΤΗΝ
ΠΛΕΥΡΑ ΠΑΡΟΧΗΣ ΟΛΩΝ ΤΩΝ ΚΛΙΜΑΤΙΣΤΙΚΩΝ ΜΟΝΑΔΩΝ
ΠΑΝΩ ΑΠΟ 944LPS ΚΑΙ ΣΤΗΝ ΠΛΕΥΡΑ ΤΗΣ ΕΠΙΣΤΡΟΦΗΣ
ΟΛΩΝ ΤΩΝ ΚΛΙΜΑΤΙΣΤΙΚΩΝ ΜΟΝΑΔΩΝ ΠΑΝΩ ΑΠΟ 7,079
LPS. ΜΟΝΑΔΕΣ ΑΠΟΚΛΕΙΣΤΙΚΑ ΑΦΙΕΡΩΜΕΝΕΣ ΣΕ ΧΩΡΟΥΣ
ΜΕ ΑΝΙΧΝΕΥΣΗ ΚΑΠΝΟΥ ΠΑΝΤΟΥ ΔΕΝ ΑΠΑΙΤΕΙΤΑΙ ΝΑ
ΕΦΟΔΙΑΣΤΟΥΝ ΜΕ ΑΝΙΧΝΕΥΣΗ ΤΥΠΟΥ ΑΕΡΑΓΩΓΟΥ. Η AHU
ΣΕ ΑΥΤΕΣ ΤΙΣ ΠΕΡΙΠΤΩΣΕΙΣ ΘΑ ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΜΕ
ΤΗΝ ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΗΣ ΑΝΙΧΝΕΥΣΗΣ ΣΤΟ ΝΤΟΥΛΑΠΙ.
PROVIDE CONTROL MODULE TO SHUT OFF POWER
TO ELECTRONICS EQUIPMENT UPON WATERFLOW
DETECTION.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΓΙΑ ΤΟ ΚΛΕΙΣΙΜΟ ΤΗΣ
ΠΑΡΟΧΗΣ ΣΤΟΝ ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ ΜΟΛΙΣ
ΑΝΙΧΝΕΥΘΕΙ ΡΟΗ ΝΕΡΟΥ.
PROVIDE ADDRESSABLE MANUAL FIRE ALARM PULL
STATION WITHIN 1.5 METERS OF ALL EXTERIOR EXIT
DOORS.
ΠΑΡΕΧΕΤΕ ΔΙΕΥΘΥΝΣΙΟΔΟΤΟΥΜΕΝΟΥΣ ΣΤΑΘΜΟΥΣ
ΕΛΞΗΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΜΕΣΑ ΣΕ 1,5 ΜΕΤΡΑ
ΑΠΟ ΟΛΕΣ ΤΙΣ ΕΞΩΤΕΡΙΚΕΣ ΠΟΡΤΕΣ.
PROVIDE A SMOKE DETECTOR ABOVE ALL FIRE ALARM
PANELS INCLUDING CLEAN AGENT RELEASE PANELS
AND AASD IF NOT IN PROTECTED COMPARTMENT. WITH
EXCEPTION OF PANELS LOCATED IN SPACES/ROOMS
WITH FULL SMOKE DETECTION THROUGHOUT.
ΠΑΡΕΧΕΤΕ ΑΝΙΧΝΕΥΤΗ ΚΑΠΝΟΥ ΠΑΝΩ ΑΠΟ ΟΛΟΥΣ ΤΟΥ
ΠΙΝΑΚΕΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ
ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΚΑΙ ΤΩΝ ΠΙΝΑΚΩΝ
ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΟΥ AASD ΕΑΝ ΔΕΝ ΕΙΝΑΙ ΜΕΣΑ ΣΕ
ΠΡΟΣΤΑΤΕΥΜΕΝΟ ΝΤΟΥΛΑΠΙ. ΕΞΑΙΡΟΥΝΤΑΙ ΟΙ ΠΙΝΑΚΕΣ
ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΧΩΡΟΥΣ/ΔΩΜΑΤΙΑ ΜΕ ΠΛΗΡΗ
ΑΝΙΧΝΕΥΣΗ ΚΑΠΝΟΥ ΠΑΝΤΟΥ.
MONITOR WATERFLOW AND TAMPER SWITCHES ON
THE WET PIPE FIRE SPRINKLER SYSTEM.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΠΟΗΣ ΚΑΙ
ΔΙΑΦΡΑΓΜΑΤΩΝ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ
ΥΓΡΟΥ ΤΥΠΟΥ.
RISER IS SCHEMATIC. CONTRACTOR IS RESPONSIBLE
FOR COORDINATION WITH FLOOR PLANS AND
PROVIDING SUFFICIENT DEVICES.
ΤΟ ΔΙΑΓΡΑΜΜΑ ΕΙΝΑΙ ΣΧΗΜΑΤΙΚΟ. Ο ΕΡΓΟΛΑΒΟΣ
ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΟ ΣΥΣΝΤΟΝΙΣΜΟ ΜΕ ΤΑ
ΣΧΕΔΙΑ ΤΩΝ ΟΡΟΦΩΝ ΚΑΙ ΤΗΝ ΠΡΟΜΗΘΕΙΑ ΑΡΚΕΤΩΝ
ΣΥΣΚΕΥΩΝ.
3 1
F IM IM
PROVIDE MONITOR MODULES IN N6 EQUIPMENT
ROOM, N9 EQUIPMENT ROOM, AND FLEET - CYBER
EQUIP ROOM FOR CLEAN AGENT RELEASING SYSTEM
PANELS AND AIR ASPIRATING DETECTION PANEL.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΣΤΑ
ΔΩΜΑΤΙΑ ΕΞΟΠΛΙΣΜΟΥ Ν6 ΚΑΙ Ν9 ΚΑΙ ΣΤΟ ΔΩΜΑΤΙΟ
ΕΞΟΠΛΙΣΜΟΥ ΚΥΒΕΡΝΟ-ΣΤΟΛΟΥ ΓΙΑ ΤΟΥΣ ΠΙΝΑΚΕΣ
ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΤΟΥ ΠΙΝΑΚΑ ΑΝΙΧΝΕΥΣΗΣ
ΑΝΑΡΟΦΗΣΗΣ ΑΕΡΑ.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
GENERATOR
ENCLOSURE
IM IMK IM IM IM IM IM IM IM
IM IM F
F IM IM
SB
IM IM IM IM IM IM
IM IMIM
SPD
MONITOR TAMPER AND FLOW SWITCHES OF THE FLOOR
CONTROL VALVES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΚΟΠΤΩΝ ΡΟΗΣ ΚΑΙ
ΔΙΑΦΡΑΓΜΑΤΩΝ ΤΩΝ ΒΑΝΩ ΕΛΕΓΧΟΥ ΤΩΝ ΟΡΟΦΩΝ.
MONITOR TAMPER SWITCHES FOR BACKFLOW
PREVENTER.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΔΙΑΦΡΑΓΜΑΤΩΝ ΤΗΣ
ΑΝΤΕΠΙΣΤΡΟΦΗΣ.
SUPERVISE KEY LOCK BOX RAPID ENTRY SYSTEM WITH
TAMPER SWITCH.
ΕΠΙΒΛΕΨΗ ΚΟΥΤΙΟΥ ΚΛΕΙΔΩΘΗΚΗΣ ΣΥΣΤΗΜΑΤΟΣ
ΤΑΧΕΙΑΣ ΕΙΣΟΔΟΥ ΜΕ ΔΙΑΚΟΠΤΗ ΔΙΑΦΡΑΓΜΑΤΟΣ
IM
CM
CM
COF IM IM IM IM
15 10
SPD
SPD
TO EXTERIOR
RPS
AMP
RPS
AMP
134S
SPD
RPS
AMP
1 2SPD
MNT
SPD
FEDERAL SIGNAL MASS NOTIFICATION TRANSCEIVER
ΠΟΜΠΟΔΕΚΤΗΣ ΟΜΟΣΠΟΝΔΟΙΑΚΟΥ ΣΗΜΑΤΟΣ ΜΑΖΙΚΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ.
LOBBY
WATCH
CENTER 305
IM IM IM
MONITOR EMEGENCY GENERATOR VIA SUPERVISORY
AND TROUBLE SIGNALS UPON PRIMARY POWER FAILURE
IN ACCORDANCE WITH 28 31 76 AND NFPA 72.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΓΕΝΝΗΤΡΙΑΣ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ
ΜΕΣΩ ΕΠΟΠΤΙΚΩΝ ΣΗΜΑΤΩΝ ΚΑΙ ΣΗΜΑΤΩΝ
ΠΡΟΒΛΗΜΑΤΩΝ ΜΕ ΤΗΝ ΠΡΩΤΗ ΑΠΟΤΥΧΙΑ ΠΑΡΟΧΗΣ
ΣΥΜΦΩΝΑ ΜΕ ΤΗ 28 31 76 ΚΑΙ ΤΟΝ NFPA 72.
18182
DEMARC 2
1 2SPD
1 2SPD
ELEC
ELEC
1 2SPD
1 2SPD
ELEC 222
ELEC 222
DEMARC 2 126
DEMARC 2
IM
MONITOR POWER SUPPLY OF TWO-WAY
EMERGENCY COMMUNICATIONS SYTEM
CONTROL UNIT.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΠΑΡΟΧΗΣ ΙΣΧΥΟΣ ΣΤΗ
ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ
ΑΜΦΙΔΡΟΜΗΣ ΕΠΙΚΟΙΝΩΝΙΑΣ ΕΚΤΑΚΤΗΣ
ΑΝΑΓΚΗΣ.
CM
PROVIDE CONTROL MODULE FOR
LIGHTING/TIMING CONTACTOR TO ACTIVATE
MEANS OF EGRESS LIGHTING.
ΠΑΡΕΧEΤΕ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΓΙΑ ΤΗΝ
ΕΠΑΦΗ ΦΩΤΙΣΜΟΥ/ΧΡΟΝΟΥ ΓΙΑ ΤΗΝ
ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΟΥ ΦΩΤΙΣΜΟΥ ΣΤΙΣ
ΟΔΕΥΣΕΙΣ ΔΙΑΦΥΓΗΣ.
DACT
PROVIDE MONITOR MODULE FOR AASD PRE-ALERT
SIGNAL AT EACH CARP
ΠΕΡΕΧΕΤΕ ΠΙΝΑΚΑ ΣΤΟΙΧΕΙΩΝ ΤΗΣ ΜΟΝΑΔΑΣ
ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ ΤΟ ΣΗΜΑ ΠΡΟ-ΣΥΝΑΓΕΡΜΟΥ ΤΟΥ
AASD ΣΕ ΚΑΘΕ CARP.
IM
IM
IM
IM
PROVIDE MONITOR MODULES FOR EPO
SHUTDOWN ASSOCIATED WITH ROOM
CONTROL MODULE.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ ΓΙΑ
ΤΕΡΜΑΤΙΣΜΟ ΛΕΙΤΟΥΡΓΙΑΣ ΤΟΥ EPO
ΣΧΕΤΙΖΟΜΕΝΟ ΜΕ ΤΗ ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ
ΔΩΜΑΤΙΟΥ.
IM
EECU
ROUTE AOR WIRING
IN E31 CONDUIT (TYPICAL)
ΔΡΟΜΟΛΟΓΗΣΤΕ ΤΙΣ ΚΑΛΩΔΙΩΣΕΙΣ ΤΗΣ
AOR ΣΕ ΣΩΛΗΝΑ ΚΑΛΩΔΙΩΝ Ε31 (ΤΥΠΙΚΟ)
TO MONITOR MODULE
ΠΡΟΣ ΜΟΝΑΔΑ
ΠΑΡΑΚΟΛΟΥΘΗΣΗΣ
POWER
SUPPLY
CST
COR
THE AREA OF REFUGE SYSTEM (AOR) MUST BE COMPLETE AND FULLY FUNCTIONAL.
THE SYSTEM MUST MEET NFPA 72 AND 101. ALL EMERGENCY CALLS WILL BE ROUTED
TO THE BASE STATION AND TO THE BASE FIRE DEPARTMENT.
ΤΟ ΣΥΣΤΗΜΑ ΤΟΥ ΧΩΡΟΥ ΚΑΤΑΦΥΓΗΣ (AOR) ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΟΛΟΚΛΗΡΩΜΕΝΟΣ ΚΑΙ ΠΛΗΡΩΣ ΛΕΙΤΟΥΡΓΙΚΟΣ. ΤΟ ΣΥΣΤΗΜΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 72 KAI 101.
ΟΛΕΑ ΟΙ ΚΛΗΣΕΙΣ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ ΠΡΕΠΙ ΝΑ ΔΡΟΜΟΛΟΓΟΥΝΤΑΙ ΠΡΟΣ ΤΟ ΣΤΑΘΜΟ ΤΗΣ ΒΑΣΗΣ ΚΑΙ ΤΗΝ ΠΥΡΟΣΒΕΣΤΙΚΗ ΥΠΗΡΕΣΙΑ ΤΗΣ ΒΑΣΗΣ.
WATCH
CENTER
CST
VEST
1 2SPD
PROVIDE INSTRUCTIONAL SIGNAGE
FROM MANUFACTURER FOR OPERATION
ADJACENT TO EACH CALL STATION.
ΠΑΡΕΧΕΤΕ ΚΑΘΟΔΗΓΗΤΙΚΗ ΣΗΜΑΝΣΗ
ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΓΙΑ
ΛΕΙΤΟΥΡΓΙΑ ΠΛΗΣΙΟΝ ΤΟΥ ΚΑΘΕ
ΣΤΑΘΜΟΥ ΚΛΗΣΕΩΝ.
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
2:
:3
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FA
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
FA503
MN ZSH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
AL
AR
M
D
ET
AI
LS
14089260
Λ
ΕΠ
ΤΟ
Μ
Ε
ΡΕ
ΙΕ
Σ
ΣΥ
ΣΤ
Η Μ
ΑΤ
Ο
Σ
ΣΥ
Ν Α
ΓΕ
Ρ
Μ Ο
Υ Π
ΥΡ
Κ
ΑΓ
ΙΑ
Σ
DPS
DPS
N.T.S.C1
PANEL MOUNTING DETAIL
ΛΕΠΤΟΜΕΡΕΙΑ ΣΤΗΡΙΞΗΣ ΠΙΝΑΚΑ
N.T.S.A1
RISER DIAGRAM
ΚΑΤΑΚΟΡΥΦΟ ΔΙΑΓΡΑΜΜΑ
NTSD3
AREA OF REFUGE RISER DIAGRAM
ΚΑΤΑΚΟΡΥΦΟ ΔΙΑΓΡΑΜΜΑ ΧΩΡΟΥ
ΚΑΤΑΦΥΓΗΣ
MASS NOTIFICATION MESSAGES
# TITLE PRE-ALERT TONE
TEMPORAL-3 CHIME,
GONG, OR CLAXON
TEMPORAL-3 TONE AT 1 kHz
AS REQUIRED BY NFPA 72
"ATTENTION! ATTENTION! A FIRE HAS BEEN REPORTED IN THE BUILDING.
PLEASE WALK TO THE NEAREST EXIT AND EVACUATE THE BUILDING TO
YOUR DESIGNATED LOCATION."
MESSAGE
1 FIRE
ΤΙΤΛΟΣ ΤΟΝΟΣ ΠΡΟΕΙΔΟΠΟΙΗΣΗΣ ΜΗΝΥΜΑ
2 INTRUDER "ATTENTION! ATTENTION! THERE IS AN ARMED INTRUDER
REPORTED ON BASE. LOCK DOWN THE BUILDING. TAKE IMMEDIATE
COVER."
3 BOMB THREAT "ATTENTION! ATTENTION! A BOMB THREAT HAS BEEN REPORTED IN THIS
BUILDING. ALL PERSONNEL ARE TO EVACUATE IMMEDIATELY USING THE
NEAREST EXIT. FURTHER INSTRUCTIONS WILL BE ISSUED OUTSIDE THE
BUILDING BY EMERGENCY RESPONSE PERSONNEL."
"ATTENTION! ATTENTION! A SEVERE WEATHER CONDITION HAS BEEN
REPORTED. PLEASE GO DIRECTLY TO THE NEAREST SHELTER AREA AND
WAIT FOR FUTHER INSTRUCTIONS."
TEMPORAL-3 CHIME,
GONG, OR CLAXON
TEMPORAL-3 CHIME,
GONG, OR CLAXON
WEATHER4
ΠΥΡΚΑΓΙΑ ΔΙΑΚΕΚΟΜΜΕΝΟΣ - 3
ΤΟΝΟΙ ΣΤΑ 1kHz ΟΠΩΣ
ΑΠΑΙΤΕΙΤΑΙ ΑΠΟ ΤΟΝ
NFPA 72
"ΠΡΟΣΟΧΗ! ΠΡΟΣΟΧΗ! ΑΝΑΦΕΡΘΗΚΕ ΠΥΡΚΑΓΙΑ ΣΤΟ ΚΤΗΡΙΟ. ΠΑΡΑΚΑΛΩ
ΠΡΟΧΩΡΗΣΤΕ ΠΡΟΣ ΤΗΝ ΠΛΗΣΙΕΣΤΕΡΗ ΕΞΟΔΟ ΚΑΙ ΕΚΚΕΝΩΣΤΕ ΤΟ
ΚΤΗΡΙΟ ΠΡΟΣ ΤΗΝ ΚΑΘΟΡΙΣΜΕΝΗ ΣΑΣ ΤΟΠΟΘΕΣΙΑ."
"ATTENTION! ATTENTION! THERE IS AN EMERGENCY SITUATION. DO NOT
EVACUATE THE BUILDING. STAY IN YOUR CURRENT LOCATION AND WAIT
FOR FURTHER INSTRUCTIONS."
TEMPORAL-3 CHIME,
GONG, OR CLAXON
SHELTER IN PLACE5
"ATTENTION! ATTENTION! WE HAVE BEEN ALERTED TO A POSSIBLE
EMERGENCY SITUATION. PLEASE STAY ALERT AND YOU WILL BE ADVISED
IF EMERGENCY ACTION IS REQUIRED."
TEMPORAL-3 CHIME,
GONG, OR CLAXON
ALERT6
"ATTENTION! ATTENTION! THIS IS A DRILL. THIS IS A DRILL.
This is the start of the file's text. The full file is on GovTribe.