ATT H 1615269dwg9of19.pdf
PDF 3 MB Posted
- Attached to
- P131 Communications Center - Souda Bay
- Solicitation number
- N62470-21-R-0005
About this file
This solicitation is for the construction of a new communications center at Naval Support Activity Souda Bay, Greece. The project involves constructing a three-story concrete facility that will house communications operations, a telephone exchange, electronics maintenance shops, and storage for electronics equipment. Electrical work includes primary power distribution, transformers, telecommunications infrastructure, security systems, and lighting. The period of performance is approximately 900 days after notice to proceed. The Navy seeks a fixed-price contract awarded through full and open competition to complete this work.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:5
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-001
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
PR
O
TE
C
TI
O N
G
EN
ER
AL
N O
TE
S
AB
BR
EV
IA
TI
O N
S
14089239
Π
ΥΡ
Ο Π
ΡΟ
ΣΤ
ΑΣ
ΙΑ
ΓΕ
Ν
ΙΚ
Ε
Σ
ΣΗ
Μ Ε
ΙΩ
ΣΕ
ΙΣ
ΣΥ
Ν
ΤΟ
Μ
Ο
ΓΡ
ΑΦ
ΙΕ
Σ
DPS
DPS
FIRE SPRINKLER SYSTEM GENERAL NOTES:
ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΚΑΓΙΑΣ
SPRINKLER SYSTEM DESIGN AND INSTALLATION MUST BE IN ACCORDANCE WITH NFPA 13 AND SPECIFICATION 21 13 13.00.20. CONTRACTOR MUST VERIFY THE LOCATION OF ALL SPRINKLER SYSTEM COMPONENTS AND COORDINATE WITH THE VARIOUS TRADES. PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE AUTOMATIC WET-PIPE SPRINKLER SYSTEM THROUGHOUT THE BUILDING AND GENERATOR ENCLOSURE. FIRE SUPPRESSION DRAWINGS SHOW A DIAGRAMMATIC SYSTEM TO INCORPORATE MAJOR ELEMENTS FOR THE CONDITIONAL APPROVAL PRIOR TO THE FINAL DESIGN AND SUBMISSION PROVIDED BY THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR THE FINAL LAOUT, DESIGN, AND CALCULATIONS. THE CONTRACTOR MUST SUBMIT THEIR DESIGN, CALCULATIONS, AND PROPOSED EQUIPMENT TO THE GOVERNMENT FOR
APPROVAL.
Ο ΣΧΕΔΙΑΣΜΟΣ ΚΑΙ Η ΕΓΚΑΤΑΣΤΑΣΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΚΑΙ ΤΗΝ ΠΡΟΔΙΑΓΡΑΦΗ 21 13
13.00.20. Ο ΕΡΓΟΛΑΒΟΣ ΠΡΕΠΕΙ ΝΑ ΕΠΙΒΕΒΑΙΩΣΕΙ ΤΗ ΘΕΣΗ ΟΛΩΝ ΤΩΝ ΜΕΡΩΝ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΚΑΙ ΝΑ ΣΥΝΤΟΝΙΣΕΙ ΜΕ ΤΟΥΣ ΥΠΟΛΟΙΠΟΥΣ ΣΥΝΑΛΛΑΣΣΟΜΕΝΟΥΣ. ΠΡΟΜΗΘΕΥΣΤΕ ΟΛΑ ΤΑ ΑΠΑΡΑΙΤΗΤΑ ΜΕΡΗ ΓΙΑ ΕΝΑ ΟΛΟΚΛΗΡΩΜΕΝΟ ΑΥΤΟΜΑΤΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΩΝΙΣΜΟΥ ΥΓΡΟΥ ΤΥΠΟΥ ΣΕ ΟΛΟ ΤΟ ΚΤΙΡΙΟ ΚΑΙ ΤΟΥ ΧΩΡΟΥ ΤΗΣ ΓΕΝΝΗΤΡΙΑΣ. ΤΑ ΣΧΕΔΙΑ ΚΑΤΑΣΤΟΛΗΣ ΠΥΡΚΑΓΙΑΣ ΔΕΙΧΝΟΥΝ ΕΝΑ ΔΙΑΓΡΑΜΜΑΤΙΚΟ ΣΥΣΤΗΜΑ ΓΙΑ ΤΗΝ ΕΝΣΩΜΑΤΩΣΗ ΤΩΝ ΒΑΣΙΚΩΝ ΣΤΟΙΧΕΙΩΝ ΓΙΑ ΤΗΝ ΥΠΟ ΟΡΟΥΣ ΠΑΡΟΧΗ ΕΓΚΡΙΣΗΣ ΠΡΙΝ ΤΟ ΤΕΛΙΚΟ ΣΧΕΔΙΟ ΚΑΙ ΤΗΝ ΥΠΟΒΟΛΗ ΠΟΥ ΠΑΡΕΧΟΝΤΑΙ ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ. Ο ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΗΝ ΤΕΛΙΚΗ ΔΙΑΤΑΞΗ, ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΚΑΙ ΤΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ. Ο ΕΡΓΟΛΑΒΟΣ ΠΡΕΠΕΙ ΝΑ ΥΠΟΒΑΛΛΕΙ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΤΟΥ, ΤΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ ΚΑΙ ΤΟΝ ΠΡΟΤΕΙΝΟΜΕΝΟ ΕΞΟΠΛΙΣΜΟ ΣΤΗΝ ΚΥΒΕΡΝΗΣΗ ΓΙΑ
ΕΓΚΡΙΣΗ.
2. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS.
ΜΗΝ ΣΧΕΔΙΑΖΕΤΕ ΥΠΟ ΚΛΙΜΑΚΑ ΓΙΑ ΤΟΝ ΠΡΟΣΔΙΟΡΙΜΟ ΤΩΝ ΔΙΑΣΤΑΣΕΩΝ.
ALL COMPONENTS, DEVICES, AND EQUIPMENT MUST BE UL LISTED OR FM APPROVED.
ΟΛΑ ΤΑ ΜΕΡΗ, ΟΙ ΣΥΣΚΕΥΕΣ ΚΑΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤΑΧΩΡΗΜΕΝΑ ΚΑΤΑ UL Ή ΕΓΚΕΚΡΙΜΜΕΝΑ ΚΑΤΑ FM.
SPRINKLER SYSTEM MUST BE HYDRAULICALLY DESIGNED USING THE AREA/DENSITY METHOD IN ACCORDANCE WITH NFPA 13. DESIGN CRITERIA MUST BE APPLIED AS INDICATED ON THE DRAWINGS. HYDRAULIC CALCULATIONS MUST INCLUDE A 10 PERCENT SAFETY FACTOR TO THE WATER SUPPLY
CURVE.
ΤΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΡΕΠΕΙ NA EINAI ΥΔΡΑΥΛΙΚΩΣ ΣΧΕΔΙΑΣΜΕΝΟ ΧΡΗΣΙΜΟΠΟΙΩΝΤΑΣ ΤΗ ΜΕΘΟΔΟ ΕΜΒΑΔΟΥ/ΠΥΚΝΟΤΗΤΑΣ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13. ΤΑ ΚΡΙΤΗΡΙΑ ΣΧΕΔΙΑΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΦΑΡΜΟΖΟΝΤΑΙ ΟΠΩΣ ΔΙΝΕΤΑΙ ΣΤΑ ΣΧΕΔΙΑ. ΟΙ ΥΔΡΑΥΛΙΚΟΙ ΥΠΟΛΟΓΙΣΜΟΙ ΠΡΕΠΕΙ ΝΑ ΠΕΡΙΛΑΜΒΑΝΟΥΝ
ΕΝΑ ΠΑΡΑΓΟΝΤΑ ΑΣΦΑΛΕΙΑΣ ΚΑΤΑ 10% ΤΗΣ ΚΑΜΠΥΛΗΣ ΠΑΡΟΧΗΣ ΝΕΡΟΥ.
5.
6.
ADHERE TO AND OBTAIN PERMITS, LICENSES AND GOVERNMENT REQUIREMENTS.
ΤΗΡΕΙΤΕ ΚΑΙ ΑΠΟΚΤΗΣΤΕ ΤΙΣ ΕΓΓΡΑΦΕΣ ΑΔΕΙΕΣ ΚΑΙ ΤΙΣ ΚΥΒΕΡΝΗΤΙΚΕΣ ΑΠΑΙΤΗΣΕΙΣ.
FIRE STOP PENETRATIONS OF SMOKE/FIRE WALLS. FIRE STOPPING MUST BE OF A U.L. LISTED AND/OR FM APPROVED ASSEMBLY.
ΠΥΡΟΦΡΑΓΜΟΣ ΣΕ ΠΥΡΑΝΤΟΧΟΥΣ ΤΟΙΧΟΥΣ. Ο ΠΥΡΟΦΡΑΓΜΟΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤΗΓΟΡΙΟΠΟΙΗΜΕΝΟΣ ΚΑΤΑ UL ΚΑΙ/Ή ΕΓΚΕΚΡΙΜΕΝΟΣ
ΑΠΟ FM ΣΥΝΑΡΜΟΛΟΓΗΣΗ.
SPRINKLER SYSTEM PIPING MUST BE PROVIDED WITH EARTHQUAKE PROTECTION IN ACCORDANCE WITH NFPA 13 AND SPECIFICATION 21 13 13.00 20.
REFER TO SHEET S-001 FOR SEISMIC DESIGN CRITERIA.
ΟΙ ΣΩΛΗΝΩΣΕΙΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΙΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΦΟΔΙΑΣΤΟΥΝ ΜΕ ΑΝΤΙΣΕΙΣΜΙΚΗ ΠΡΟΣΤΑΣΙΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΚΑΙ ΤΗΝ ΠΡΟΔΙΑΓΡΑΦΗ 21 13 13.00 20. ΔΕΙΤΕ ΤΟ ΣΧΕΔΙΟ S-001 ΓΙΑ ΤΑ ΚΡΙΤΗΡΙΑ ΣΕΙΣΜΙΚΟΥ ΣΧΕΔΙΑΣΜΟΥ.
CONTROL VALVES AND FLOW SWITCHES FOR THE FIRE SPRINKLER SYSTEMS MUST BE ELECTRONICALLY SUPERVISED AND MONITORED BY BASE FIRE DEPARTMENT. FLOW AND TAMPER SWITCHES MUST BE FURNISHED AND INSTALLED BY FIRE SPRINKLER CONTRACTOR. WIRING TO FIRE ALARM
SYSTEM MUST BE TERMINATED AND TESTED BY FIRE ALARM CONTRACTOR.
ΟΙ ΒΑΝΕΣ ΕΛΕΓΧΟΥ ΚΑΙ ΟΙ ΔΙΑΚΟΠΤΕΣ ΡΟΗΣ ΓΙΑ ΤΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΚΑΓΙΑΣ ΠΡΕΠΕΙ ΝΑ ΕΠΙΒΛΕΠΟΝΤΑΙ ΗΛΕΚΤΡΟΝΙΚΑ ΚΑΙ ΝΑ ΠΑΡΑΚΟΛΟΥΘΟΥΝΤΑΙ ΑΠΟ ΤΟ ΠΥΡΟΣΒΕΣΤΙΚΟ ΣΩΜΑ ΤΗΣ ΒΑΣΗΣ. ΟΙ ΔΙΑΚΟΠΤΕΣ ΡΟΗΣ ΚΑΙ ΕΛΕΓΧΟΥ ΘΕΣΕΩΣ ΠΡΕΠΕΙ ΝΑ ΠΡΟΜΗΘΕΥΤΟΥΝ ΚΑΙ ΝΑ ΤΟΠΟΘΕΤΗΘΟΥΝ ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΥΡΚΑΓΙΑΣ. ΟΙ ΚΑΛΩΔΙΩΣΕΙΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΠΡΕΠΕΙ ΝΑ ΤΕΡΜΑΤΙΣΤΟΥΝ ΚΑΙ ΝΑ ΕΛΕΓΧΘΟΥΝ ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ.
CONTROL, DRAIN AND TEST CONNECTION VALVES MUST BE PROVIDED WITH PERMANENTLY MARKED WEATHERPROOF METAL OR PLASTIC IDENTIFICATION SIGNS. THE SIGN MUST BE SECURED WITH CORROSION-RESISTANT WIRE, CHAIN, OR OTHER APPROVED MEANS. SIGNS MUST
INDICATE NORMAL OPERATING CONDITION (I.E. NORMALLY OPEN OR NORMALLY CLOSED).
ΟΙ ΒΑΝΕΣ ΕΛΕΓΧΟΥ, ΑΠΟΣΤΡΑΓΓΙΣΗΣ ΚΑΙ ΔΟΚΙΜΗΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΜΕ ΜΟΝΙΜΑ ΜΑΡΚΑΡΙΣΜΕΝΕΣ, ΑΝΘΕΚΤΙΚΕΣ ΣΤΟΝ ΚΑΙΡΟ, ΜΕΤΑΛΛΙΚΕΣ Ή ΠΛΑΣΤΙΚΕΣ ΠΙΝΑΚΙΔΕΣ ΑΝΑΓΝΩΡΙΣΗΣ. Η ΠΙΝΑΚΙΔΑ ΠΡΕΠΕΙ ΝΑ ΑΣΦΑΛΙΖΕΤΑΙ ΜΕ ΑΝΘΕΚΤΙΚΟ ΣΤΗΝ ΔΙΑΒΡΩΣΗ ΣΥΡΜΑ, ΑΛΥΣΙΔΑ Ή ΑΛΛΑ ΕΓΚΕΚΡΙΜΕΝΑ ΜΕΣΑ. ΟΙ ΠΙΝΑΚΙΔΕΣ ΠΡΕΠΕΙ ΝΑ ΥΠΟΔΕΙΚΝΥΟΥΝ ΤΗΝ ΚΑΝΟΝΙΚΗ ΚΑΤΑΣΤΑΣΗ ΛΕΙΤΟΥΡΓΕΙΑΣ (ΔΗΛΑΔΗ ΚΑΝΟΝΙΚΑ ΑΝΟΙΚΤΗ Ή ΚΑΝΟΝΙΚΑ ΚΛΕΙΣΤΗ) SUBMIT COMPLETE SHOP DRAWINGS, MATERIAL DATA, HYDRAULIC CALCULATONS, AND FLOW TEST RESULTS TO CONTRACTING OFFICER FOR
REVIEW AND APPROVAL PRIOR TO COMMENCING FABRICATION AND INSTALLATION.
ΥΠΟΒΑΛΕΤΕ ΟΛΟΚΛΗΡΩΜΕΝΑ ΣΧΕΔΙΑ ΕΦΑΡΜΟΓΗΣ, ΔΕΔΟΜΕΝΑ ΤΩΝ ΥΛΙΚΩΝ , ΥΔΡΑΥΛΙΚΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ ΚΑΙ ΑΠΟΤΕΛΕΣΜΑΤΑ ΔΟΚΙΜΗΣ ΡΟΗΣ ΣΤΟΝ ΑΞΙΩΜΑΤΙΚΟ ΤΟΥ ΕΡΓΟΥ ΓΙΑ ΕΛΕΓΧΟ ΚΑΙ ΕΓΚΡΙΣΗ ΠΡΙΝ ΤΗΝ ΕΝΑΡΞΗ ΤΗΣ ΚΑΤΑΣΚΕΥΗΣ ΚΑΙ ΤΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ.
11.
12.
13.
PENDENT SPRINKLERS MUST BE INSTALLED ON RETURN BENDS. THE USE OF A SIDE OUTLET TEE THAT REQUIRES A HOLE DRILLED IN THE PIPE W ITH
A WRAP AROUND BAND AND RUBBER GASKET ARE PROHIBITED.
ΚΡΕΜΑΣΤΟΙ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΣΕ ΔΙΑΤΑΞΗ ΣΩΛΗΝΩΣΕΩΝ ΟΠΟΥ ΟΙ ΣΩΛΗΝΩΣΕΙΣ ΒΓΑΙΝΟΥΝ ΑΠΟ ΤΗΝ ΚΟΡΥΦΗ ΤΟΥ ΣΩΛΗΝΑ ΔΙΑΚΛΑΔΩΣΗΣ (ΚΑΤΑΚΟΡΥΦΗ ΑΝΥΨΩΣΗ), ΟΔΕΥΟΥΝ ΟΡΙΖΟΝΤΙΑ ΚΑΙ ΕΠΕΙΤΑ ΠΡΟΣ ΤΑ ΚΑΤΩ ΠΡΟΣ ΤΟΝ ΚΑΤΑΙΟΝΗΤΗΡΑ. Η ΧΡΗΣΗ ΤΑΥ ΠΛΑΪΝΗΣ ΕΞΟΔΟΥ ΤΟ ΟΠΟΙΟ ΧΡΕΙΑΖΕΤΑΙ ΤΡΥΠΑ ΣΤΟ ΣΩΛΗΝΑ ΜΕ ΤΥΛΙΓΜΑ ΓΥΡΩ ΤΟΥ ΚΑΙ ΦΛΑΝΤΖΑ ΑΠΟ ΚΑΟΥΤΣΟΥΚ ΑΠΑΓΟΡΕΥΕΤΑΙ.
PROVIDE A MINIMUM OF 1 M OF CLEARANCE IN FRONT OF EQUIPMENT AND 150 MM BEHIND THE EQUIPMENT (I.E. CONTROL VALVES, RISERS, ETC).
ΠΑΡΕΧΕΤΕ ΚΑΤ' ΕΛΑΧΙΣΤΟ ΑΠΟΣΤΑΣΗ 1Μ ΜΠΡΟΣΤΑ ΑΠΟ ΤΟΝ ΕΞΟΠΛΙΣΜΟ ΚΑΙ 150ΜΜ ΠΙΣΩ ΑΠΟ ΤΟΝ ΕΞΟΠΛΙΣΜΟ (ΔΗΛΑΔΗ ΒΑΝΕΣ ΕΛΕΓΧΟΥ, ΣΤΗΛΕΣ
ΑΝΟΔΟΥ, ΚΛΠ)
MECHANICAL COUPLINGS, GASKETS AND FITTINGS MUST BE FROM THE SAME MANUFACTURER.
ΟΙ ΜΗΧΑΝΙΚΟΙ ΣΥΝΔΕΣΜΟΙ, ΤΑ ΠΕΡΙΒΛΗΜΑΤΑ ΚΑΙ ΤΑ ΕΞΑΡΤΗΜΑΤΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΑΠΟ ΤΟΝ ΙΔΙΟ ΚΑΤΑΣΚΕΥΑΣΤΗ.
SPRINKLER 2.1 M OR LESS ABOVE FINISHED FLOOR, WHERE SUBJECT TO MECHANICAL DAMAGE, OR WHERE THE SPRINKLER CAN BE REACHED FROM
FLOOR LEVEL, MUST BE PROVIDED WITH UL LISTED SPRINKLER GUARDS.
ΚΑΤΑΙΟΝΗΤΗΡΕΣ 2.1Μ Ή ΛΙΓΟΤΕΡΟ ΠΑΝΩ ΑΠΟ ΤΟ ΤΕΛΕΙΩΜΕΝΟ ΔΑΠΕΔΟ, ΟΠΟΥ ΥΠΟΚΕΙΝΤΑΙ ΣΕ ΜΗΧΑΝΙΚΑ ΠΛΗΓΜΑΤΑ, Ή ΟΠΟΥ ΟΙ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΕΙΝΑΙ ΠΡΟΣΒΑΣΙΜΗ ΑΠΟ ΤΟ ΕΠΙΠΕΔΟ ΤΟΥ ΟΡΟΦΟΥ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΜΕ ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΑΤΑΧΩΡΗΜΕΝΑ ΚΑΤΑ UL.
CLEAN, PRE-TREAT, AND PRIME ALL EXPOSED SPRINKLER PIPING. PAINT EXPOSED SPRINKLER PIPING WITH ONE COAT OF RED ALKYD GLOSS
ENAMEL.
INSTALL LABELS & FLOW ARROWS AFTER PAINT IS DRY. FLOW ARROWS NOT REQUIRED ON LOOP OR GRIDDED SYSTEMS.
ΕΤΟΙΜΑΣΤΕ, ΚΑΘΑΡΙΣΤΕ ΚΑΙ ΕΠΕΞΕΡΓΑΣΤEIΤΕ ΧΗΜΙΚΑ ΟΛΕΣ ΤΙΣ ΕΚΤΕΘΕΙΜΕΝΕΣ ΣΩΛΗΝΩΣΕΙΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ. ΒΑΨΤΕ ΤΙΣ ΕΚΤΕΘΕΙΜΕΝΕΣ ΣΩΛΗΝΕΣ ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΜΕ ΜΙΑ ΣΤΡΩΣΗ ΚΟΚΚΙΝΗΣ ΕΠΙΣΜΑΛΤΩΜΕΝΗΣ ΑΛΚΥΔΙΚΗΣ ΡΗΤΙΝΗΣ. ΤΟΠΟΘΕΤΗΣΤΕ ΕΠΙΓΡΑΦΕΣ ΚΑΙ ΒΕΛΗ ΡΟΗΣ ΜΕΤΑ ΠΟΥ ΘΑ ΣΤΕΓΝΩΣΕΙ Η ΒΑΦΗ. ΔΕΝ ΑΠΑΙΤΟΥΝΤΑΙ ΒΕΛΗ ΡΟΗΣ ΣΤΟΥΣ ΒΡΟΧΟΥΣ Ή ΣΤΑ ΣΥΣΤΗΜΑΤΑ ΕΝΤΟΣ ΣΧΑΡΑΣ.
15.
16. CUTTING STRUCTURAL MEMBERS OR REINFORCING FOR PASSAGE OF PIPES OR FOR PIPE-HANGER FASTENINGS IS PROHIBITED. PIPES THAT MUST PENETRATE CONCRETE WALLS OR CONCRETE FLOORS MUST BE PROVIDED WITH CAST-IN-PLACE PIPE SLEEVES. PIPES THAT MUST PENETRATE MASONRY WALLS MUST BE CORE-DRILLED WITHOUT CUTTING REINFORCING AND PROVIDED WITH PIPE SLEEVES.
Η ΚΟΠΗ ΔΟΜΙΚΩΝ ΣΤΟΙΧΕΙΩΝ 'Η Η ΕΝΙΣΧΥΣΗ ΓΙΑ ΤΗΝ ΔΙΕΛΕΥΣΗ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ Ή ΤΗΝ ΣΤΕΡΕΩΣΗ ΤΩΝ ΣΤΗΡΙΓΜΑΤΩΝ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΔΕΝ ΕΠΙΤΡΕΠΕΤΑΙ. ΟΙ ΣΩΛΗΝΩΣΕΙΣ ΠΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΠΕΡΑΣΟΥΝ ΤΟΙΧΟΥΣ ΑΠΟ ΣΚΥΡΟΔΕΜΑ Ή ΔΑΠΕΔΑ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΜΕ ΜΑΝΔΥΕΣ ΣΩΛΗΝΩΣΕΩΝ ΚΑΤΑΣΚΕΥΑΣΜΕΝΟΥΣ ΕΠΙ ΤΟΠΟΥ. ΓΙΑ ΤΙΣ ΣΩΛΗΝΩΣΕΙΣ ΠΟΥ ΠΡΕΠΕΙ ΝΑ ΔΙΑΠΕΡΑΣΟΥΝ ΠΛΙΝΘΟΚΤΙΣΤΗ ΤΟΙΧΟΠΟΙΙΑ, ΠΡΕΠΕΙ ΝΑ ΓΙΝΕΤΑΙ ΜΕ ΚΑΡΟΤΙΕΡΑ ΔΙΑΤΡΗΣΗΣ ΧΩΡΙΣ NA ΚΟΒΕΤΑΙ Η ΕΝΙΣΧΥΣΗ ΚΑΙ ΝΑ ΠΑΡΕΧΟΝΤΑΙ ΜΕ ΜΑΝΔΥΕΣ ΣΩΛΗΝΩΣΕΩΝ.
CODES AND STANDARDS
ΚΩΔΙΚΕΣ ΚΑΙ ΠΡΟΤΥΠΑ
AT A MINIMUM THE FOLLOWING CODES AND STANDARDS APPLY:
ΚΑΤ' ΕΛΑΧΙΣΤΟ ΙΣΧΥΟΥΝ ΟΙ ΑΚΟΛΟΥΘΟΙ ΚΩΔΙΚΕΣ ΚΑΙ ΠΡΟΤΥΠΑ:
NFPA 1 - 2018 EDITION, FIRE CODE.
NFPA 1 - ΕΚΔΟΣΗ 2018, ΚΩΔΙΚΑΣ ΠΥΡΚΑΓΙΑΣ
NFPA 10 - 2018 EDITION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS.
NFPA 10 - ΕΚΔΟΣΗ 2018, ΠΡΟΤΥΠΟ ΓΙΑ ΦΟΡΗΤΟΥΣ ΠΥΡΟΣΒΕΣΤΗΡΕΣ
NFPA 13 - 2019 EDITION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
NFPA 13 - ΕΚΔΟΣΗ 2019, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ
NFPA 24 - 2019 EDITION, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS
AND THEIR APPURTENANCES.
NFPA 24 - ΕΚΔΟΣΗ 2019, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗΙΔΙΩΤΙΚΩΝ ΚΕΝΤΡΩΝ ΠΥΡΟΣΒΕΣΗΣ
ΚΑΙ ΤΑ ΠΛΕΟΝΕΚΤΗΜΑΤΑ ΤΟΥΣ
NFPA 72 - 2019 EDITION, NATIONAL FIRE ALARM AND SIGNALING CODE.
NFPA 72 - ΕΚΔΟΣΗ 2019, ΑΜΕΡΙΚΑΝΙΚΟΣ ΚΩΔΙΚΑΣΥΝΑΓΕΡΜΟΥ ΠΥΡΚΑΓΙΑΣ ΚΑΙ ΣΗΜΑΝΣΗΣ
ACC
ADJ
AFF
ALT
APPROX
ARCH
BLDG
BOT
CLG
CL -
CMU
CONN
CORR
DET
DIA
DIM
DIV
DN
DWG
EA
ELEV
EQUIP
FACP
FDC
FH
FLG
FLR
ACCESS
ΠΡΟΣΒΑΣΗ
ADJUSTABLE
ΕΥΠΡΟΣΑΡΜΟΣΤΟΣ
ABOVE FINISHED FLOOR
ΠΑΝΩ ΑΠΟ ΤΕΛΕΙΩΜΕΝΟ ΔΑΠΕΔΟ
ALTERNATE
ΕΝΑΛΛΑΚΤΙΚΟ
APPROXIMATE
ΚΑΤΑ ΠΡΟΣΕΓΓΙΣΗ
ARCHITECTURAL
ΑΡΧΙΤΕΚΤΟΝΙΚΟΣ
BUILDING
ΚΤΙΡΙΟ
BOTTOM
ΚΑΤΩ ΜΕΡΟΣ
CENTERLINE
ΓΡΑΜΜΗ ΚΕΝΤΡΟΥ
CEILING
ΟΡΟΦΗ
CONCRETE MASONRY UNIT
ΜΟΝΑΔΑ ΤΟΙΧΟΠΟΙΙΑΣ ΑΠΟ ΣΚΥΡΟΔΕΜΑ
CONNECTION/CONNECT
ΣΥΝΔΕΣΗ/ΣΥΝΔΕΣΤΕ
CORRIDOR
ΔΙΑΔΡΟΜΟΣ
DIAMETER
DETAIL
ΛΕΠΤΟΜΕΡΕΙΑ
ΔΙΑΜΕΤΡΟΣ
DIMENSION
ΔΙΑΣΤΑΣΗ
DIVISION
ΤΜΗΜΑ
DOWN
DRAWING
ΣΧΕΔΙΟ
EACH
ΚΑΘΕ
ELEVATION
ΥΨΟΜΕΤΡΟ - ΟΨΗ
EQUIPMENT
ΕΞΟΠΛΙΣΜΟΣ
FIRE ALARM CONTROL PANEL
ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΝΑΓΕΡΜΟΥ
ΠΥΡΚΑΓΙΑΣ
FIRE DEPARTMENT CONNECTION
ΣΥΝΔΕΣΗ ΤΗΣ ΠΥΡΟΣΒΕΣΤΙΚΗΣ
ΥΠΗΡΕΣΙΑΣ
FIRE HYDRANT
ΠΥΡΟΣΒΕΣΤΙΚΟΣ ΚΡΟΥΝΟΣ
FLANGE
ΦΛΑΝΤΖΑ
FLOOR
ΔΑΠΕΔΟ
LPM
GA
GALV
HVLS
IAW
LTG
MH
MAX
MFR
MIN
MJ
MISC
MTG
MTD
NO
NOM
NPT
NTS
OD
OC
Ø
PRESS
PIV
RAD
REQD
RPM -
LITERS PER MINUTE
GAUGE
SHT
ΛΙΤΡΑ ΑΝΑ ΛΕΠΤΟ
ΤΥΠΟΠΟΙΗΜΕΝΟΣ ΔΕΙΚΤΗΣ
GALVANIZED
ΓΑΛΒΑΝΙΣΜΕΝΟ
HIGH VOLUME LOW SPEED
ΥΨΗΛΟΥ ΟΓΚΟΥ ΧΑΜΗΛΗΣ
ΤΑΧΥΤΗΤΑΣ
IN ACCORDANCE WITH
ΣΥΜΦΩΝΑ ΜΕ
LIGHTING
ΦΩΤΙΣΜΟΣ
TYP
MANHOLE
ΑΝΘΡΩΠΟΘΥΡΙΔΑ
MAXIMUM
ΜΕΓΙΣΤΟ
MANUFACTURER
ΚΑΤΑΣΚΕΥΑΣΤΗΣ
MINIMUM
ΕΛΑΧΙΣΤΟ
MECHANICAL JOINT
ΜΗΧΑΝΙΚΗ ΣΥΝΔΕΣΗ
MOUNTED
MISCELLANEOUS
ΔΙΑΦΟΡΑ
ΣΤΗΡΙΓΜΕΝΟ
MOUNTING
ΣΤΗΡΙΞΗ
NUMBER
ΑΡΙΘΜΟΣ
NOMINAL
ΟΝΟΜΑΣΤΙΚΟΣ
OUTSIDE DIAMETER
PHASE
PRESSURE
NATIONAL PIPE THREAD
NOT TO SCALE
ΑΜΕΡΙΚΑΝΙΚΟ ΣΠΕΙΡΩΜΑ
ΣΩΛΗΝΩΣΕΩΝ
ΧΩΡΙΣ ΚΛΙΜΑΚΑ
ON CENTER
ΣΤΟ ΚΕΝΤΡΟ
ΕΞΩΤΕΡΙΚΗ ΔΙΑΜΕΤΡΟΣ
ΦΑΣΗ
ΠΙΕΣΗ
POST INDICATING VALVE
ΒΑΛΒΙΔΑ ΥΠΟΔΕΙΚΝΥΟΜΕΝΗΣ ΘΕΣΗΣ
RADIUS
ΑΚΤΙΝΑ ΚΥΚΛΟΥ
REQUIRED
ΑΠΑΙΤΕΙΤΑΙ
REVOLUTIONS PER MINUTE
ΣΤΡΟΦΕΣ ΑΝΑ ΛΕΠΤΟ
UNO
VOL
W/
W/O
TYPICAL
ΤΥΠΙΚΟ
UNLESS NOTED
OTHERWISE
ΕΚΤΟΣ ΕΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
VOLUME
ΟΓΚΟΣ
WITH
ΜΕ
WITHOUT
ΧΩΡΙΣ
SPEC
SP
TEMP
SQ
SHEET
ΦΥΛΛΟ/ΣΧΕΔΙΟ
SPECIFICATION
ΠΡΟΔΙΑΓΡΑΦΗ
SQUARE
SPRINKLER
ΚΑΤΑΙΟΝΗΤΗΡΑΣ
ΤΕΤΡΑΓΩΝΟ
TEMPERATURE
ΘΕΡΜΟΚΡΑΣΙΑ
ABBREVIATIONS
ΣΥΝΤΟΜΟΓΡΑΦΙΕΣ
14.
10.
9.
8.
7.
4.
3.
ΚΑΤΩ
1.
KPA - KILOPASCALS
ΚΙΛΟΠΑΣΚΑΛ
CLEAN AGENT FIRE EXTINGUISHING SYSTEM GENERAL NOTES:
ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΩΝ ΠΥΡΟΣΒΕΣΤΙΚΩΝ ΠΑΡΑΓΟΝΤΩΝ
DESIGN AND INSTALLATION OF TOTAL FLOODING CLEAN AGENT FIRE EXTINGUISHING SYSTEM (FK-5-1-12) MUST BE IN ACCORDANCE WITH NFPA 2001, UFC 3-600-01, AND SPECIFICATION 21 22 00.00 40. PROVIDE CLEAN AGENT FIRE EXTINGUISHING SYSTEM THROUGHOUT AREAS INDICATED ON THE DRAWINGS.
Ο ΣΧΕΔΙΑΣΜΟΣ ΚΑΙ Η ΕΓΚΑΤΑΣΤΑΣΗ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΠΥΡΟΣΒΕΣΗΣ ΟΛΙΚΗΣ ΚΑΤΑΚΛΥΣΗΣ ΜΕ ΚΑΘΑΡΟ ΠΥΡΟΣΒΕΣΤΙΚΟ ΠΑΡΑΓΟΝΤΑ (FK-5-1-12) ΠΡΕΠΕΙ ΝΑ ΓΙΝΕΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 2001, TO UFC 3-600-01 KAI ΤΗΝ ΠΡΟΔΙΑΓΡΑΦΗ 21 22 00.00 40. ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΚΑΤΑΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΣΕ ΟΛΟΥΣ
ΤΟΥΣ ΧΩΡΟΥΣ ΠΟΥ ΔΙΝΟΝΤΑΙ ΣΤΑ ΣΧΕΔΙΑ
SIGNAGE THAT STATES OPERATION OF MANUAL DISCHARGE STATION WILL RELEASE FIRE SUPPRESSION AGENT TO BE PROVIDED AT ALL MANUAL RELEASE STATIONS. MANUAL RELEASE STATIONS TO BE
PROVIDED IN A COLOR OTHER THAN RED.
ΣΗΜΑΝΣΗ ΟΤΙ Ο ΣΤΑΘΜΟΣ ΧΕΙΡΟΚΙΝΗΤΗΣ ΛΕΙΤΟΥΡΓΙΑΣ ΕΚΚΕΝΩΣΗΣ ΘΑ ΑΠΕΛΕΥΘΕΡΩΝΕΙ ΠΑΡΑΓΟΝΤΑ ΚΑΤΑΣΒΕΣΗΣ ΠΥΡΚΑΓΙΑΣ ΝΑ ΤΟΠΟΘΕΤΗΘΕΙ ΣΕ ΟΛΟΥΣ ΤΟΥΣ ΧΕΙΡΟΚΙΝΗΤΟΥΣ ΣΤΑΘΜΟΥΣ ΑΠΕΛΕΥΘΕΡΩΣΗΣ.
ENSURE ALL NOZZLES AND PIPING ARE PLUMB. INSTALL 180 DEGREE NOZZLES WITH ORFICES OPPOSITE THE
NEAR WALL. PROVIDE CYLINDER MOUNTING ACCORDING TO MANUFACTURER'S RECOMMENDATION.
ΒΕΒΑΙΩΘΕΙΤΕ ΟΤΙ ΤΑ ΑΚΡΟΦΥΣΙΑ ΚΑΙ ΣΩΛΗΝΩΣΕΙΣ ΕΙΝΑΙ ΚΑΘΕΤΑ. ΤΟΠΟΘΕΤΗΣΤΕ ΑΚΡΟΦΥΣΙΑ 180 ΜΟΙΡΩΝ ΜΕ ΟΠΕΣ ΑΠΕΝΑΝΤΙ ΑΠΟ ΤΟΝ ΚΟΝΤΙΝΟ ΤΟΙΧΟ. ΠΑΡΕΧΕΤΕ ΣΤΗΡΙΞΗ ΠΥΡΟΣΒΕΣΤΗΡΩΝ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΟΔΗΓΙΕΣ
ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
CLEAN AGENT SYSTEM PIPING AND FITTINGS MUST CONFORM WITH NFPA 2001.
ΣΩΛΗΝΩΣΕΙΣ ΚΑΙ ΕΞΑΡΤΗΜΑΤΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΠΡΕΠΕΙ ΝΑ ΣΥΜΜΟΡΦΩΝΟΝΤΑΙ
ΜΕ ΤΟΝ NFPA 2001
UPON COMPLETION OF INSTALLATION, PROVIDE ENCLOSURE INTEGRITY TESTING IN ACCORDANCE WITH NFPA 2001 APPENDIX C. TESTING MUST BE WITNESSED BY THE CONTRACTORS QUALIFIED FIRE PROTECTION ENGINEER AND NAVFAC DESIGNATED FIRE PROTECTION ENGINEER. PROVIDE RELIEF VENTS
AS NECESSARY TO PREVENT OVERPRESSURIZATION DURING SYSTEM DISCHARGE.
ΜΕ ΤΗΝ ΟΛΟΚΛΗΡΩΣΗ ΤΗΣ ΕΓΚΑΤΑΣΤΑΣΗΣ, ΠΑΡΕΧΕΤΕ ΕΛΕΓΧΟΥΣ ΔΟΚΙΜΩΝ ΤΗΣ ΑΚΕΡΑΙΟΤΗΤΑΣ ΤΗΣ ΠΕΡΙΦΡΑΞΗΣ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 2001, ΠΑΡΑΡΤΗΜΑ C. ΣΤΟΥΣ ΕΛΕΓΧΟΥΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΙΣΤΑΝΤΑΙ Ο
ΠΙΣΤΟΠΟΙΗΜΕΝΟΣ ΜΗΧΑΝΙΚΟΣ ΠΥΡΑΣΦΑΛΕΙΑΣ ΤΟΥ ΕΡΓΟΛΑΒΟΥ ΚΑΙ Ο ΚΑΘΟΡΙΣΜΕΝΟΣ ΜΗΧΑΝΙΚΟΣ
ΠΥΡΑΣΦΑΛΕΙΑΣ ΤΟΥ NAVFAC. ΠΑΡΕΧΕΤΕ ΕΚΤΟΝΩΤΕΣ ΟΠΩΣ ΧΡΕΙΑΖΕΤΑΙ ΓΙΑ ΤΗΝ ΑΠΟΦΥΓΗ ΥΠΕΡΣΥΜΠΙΕΣΗΣ
ΚΑΤΑ ΤΗ ΔΙΑΡΚΕΙΑ ΕΚΤΟΝΩΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ.
THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL DESIGN LAYOUT TO BE UTILIZED AS GUIDANCE FOR PLANNING OF CLEAN AGENT FIRE SUPPRESSION SYSTEMS BY THE AWARDED CONTRACTOR. CONTRACTOR MUST PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL BY THE ENGINEER AND AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. SHOP DRAWINGS AND CALCULATIONS SUBMITTALS MUST INCLUDE ANY ADDITIONAL EQUIPMENT NECESSARY TO PROVIDE A COMPLETE INSTALLATION AND COMPLY
WITH BASE STANDARDS.
ΑΥΤΑ ΤΑ ΕΓΓΡΑΦΑ ΠΕΡΙΓΡΑΦΟΥΝ ΕΝΑ ΕΠΙΠΕΔΟ ΑΠΟΔΟΣΗΣ ΣΧΕΔΙΑΣΜΟΥ ΓΙΑ ΝΑ ΧΡΗΣΙΜΟΠΟΙΗΘΕΙ ΓΙΑ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΠΟ ΤΟΝ ΑΝΑΤΕΘΕΙΜΕΝΟ ΕΡΓΟΛΑΒΟ. Ο ΕΡΓΟΛΑΒΟΣ ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΕΙ ΟΛΟΚΛΗΡΩΜΕΝΑ ΕΓΓΡΑΦΑ ΓΙΑ ΕΛΕΓΧΟ ΚΑΙ ΕΓΚΡΙΣΗ ΑΠΟ ΤΟΝ ΜΗΧΑΝΙΚΟ ΚΑΙ ΤΗΝ ΑΡΜΟΔΙΑ ΑΡΧΗ ΠΡΙΝ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ. ΥΠΟΒΟΛΕΣ ΣΧΕΔΙΩΝ ΕΦΑΡΜΟΓΗΣ ΚΑΙ ΥΠΟΛΟΓΙΣΜΩΝ
ΠΡΕΠΕΙ ΝΑ ΠΕΡΙΛΑΜΒΑΝΟΥΝ ΟΠΟΙΟΔΗΠΟΤΕ ΕΠΙΠΡΟΣΘΕΤΟ ΕΞΟΠΛΙΣΜΟ ΑΠΑΡΑΙΤΗΤΟ ΓΙΑ ΜΙΑ
ΟΛΟΚΛΗΡΩΜΕΝΗ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΣΥΜΜΟΡΦΩΣΗ ΜΕ ΤΑ ΠΡΟΤΥΠΑ ΤΗΣ ΒΑΣΗΣ.
1.
3.
4.
5.
6.
7.
8.
REFER TO
ΠΑΡΑΠΟΜΠΗ
DRAWING/DETAIL
NUMBER
ΣΧΕΔΙΟ/ΑΡΙΘΜΟΣ
ΛΕΠΡΟΜΕΡΕΙΑΣ
SHEET NUMBER ON WHICH
CONDITION IS SHOWN
ΑΡΙΘΜΟΣ ΣΧΕΔΙΟΥ ΠΟΥ
ΔΙΝΕΤΑΙ Η ΣΥΝΘΗΚΗ
RE: A1/F-001
DRAWING REFERENCE
GREEK TRANSLATION
A1
ALL DEVICES, EQUIPMENT, AND COMPONENTS MUST BE UL LISTED OR FM APPROVED.
ΟΛΕΣ ΟΙ ΣΥΣΚΕΥΕΣ, O ΕΞΟΠΛΙΣΜΟΣ ΚΑΙ ΤΑ ΕΞΑΡΤΗΜΑΤΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΑΤΑΧΩΡΗΜΕΝΑ ΚΑΤΑ UL Ή
ΕΓΚΕΚΡΙΜΕΝΑ ΚΑΤ FM.
2.
DEVICE LOCATIONS, PIPE AND CONDUIT ROUTINGS ARE CONCEPTUAL. FINAL QUANTITY AND LAYOUT MUST BE IN ACCORDANCE WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS AND EQUIPMENT
LISTINGS. COORDINATE EQUIPMENT LOCATIONS WITH ALL BUILDING TRADES.
ΟΙ ΘΕΣΕΙΣ ΤΩΝ ΣΥΣΚΕΥΩΝ, ΟΙ ΔΙΕΛΕΥΣΕΙΣ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΚΑΙ ΤΩΝ ΣΩΛΗΝΩΣΕΩΝ ΚΑΛΩΔΙΩΝ ΕΙΝΑΙ ΣΕ ΠΡΩΙΜΗ ΦΑΣΗ ΣΧΕΔΙΑΣΜΟΥ. ΟΙ ΤΕΛΙΚΕΣ ΠΟΣΟΤΗΤΕΣ ΚΑΙ Η ΤΕΛΙΚΗ ΔΙΑΤΑΞΗ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΥΜΦΩΝΑ ΜΕ ΤΟΥΣ ΕΦΑΡΜΟΣΙΜΟΥΣ ΚΩΔΙΚΕΣ, ΤΙΣ ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ ΚΑΙ ΤΙΣ ΚΑΤΑΧΩΡΗΣΕΙΣ ΤΟΥ ΕΞΟΠΛΙΣΜΟΥ.
ΣΥΝΤΟΝΙΣΤΕ ΤΙΣ ΘΕΣΕΙΣ ΤΟΥ ΕΞΟΠΛΙΣΜΟΥ ΜΕ ΟΛΕΣ ΤΙΣ ΟΙΚΟΔΟΜΙΚΕΣ ΕΡΓΑΣΙΕΣ.
9. THE MINIMUM DESIGN CONCENTRATION MUST BE 5%. THE DESIGN TEMPERATURE IS 22 DEGREES CELSIUS
AT A RELATIVE HUMIDITY OF 40 - 55%. THE DESIGN ALTITUDE IS 140 METERS.
Η ΕΛΑΧΙΣΤΗ ΣΥΓΚΕΝΤΡΩΣΗ ΣΧΕΔΙΑΣΜΟΥ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ 5%. Η ΘΕΡΜΟΚΡΑΣΙΑ ΣΧΕΔΙΑΣΜΟΥ 22 ΒΑΘΜΟΙ
ΚΕΛΣΙΟΥ ΣΕ ΣΧΕΤΙΚΗ ΥΓΡΑΣΙΑ 40-55%. ΤΟ ΥΨΟΜΕΤΡΟ ΣΧΕΔΙΑΣΜΟΥ ΕΙΝΑΙ 140 ΜΕΤΡΑ.
10.PIPING AND FITTINGS MUST COMPLY WITH NFPA 2001. CLEAN AGENT FIRE EXTINGUISHING SYSTEM COMPONENTS MUST BE PROVIDED WITH EARTHQUAKE PROTECTION IN ACCORDANCE WITH MSS SP-127.
ALL SYSTEM PIPING IN FINISHED AREAS MUST BE CONCEALED FROM VIEW. PROVIDE RELIEF VENTS AS
NECESSARY TO PREVENT OVERPRESSURIZATION DURING SYSTEM DISCHARGE.
ΟΙ ΣΩΛΗΝΩΣΕΙΣ ΚΑΙ ΤΑ ΕΞΑΡΤΗΜΑΤΑ ΠΡΕΠΕΙ ΝΑ ΣΥΜΜΟΡΦΩΝΟΝΤΑΙ ΜΕ ΤΟΝ NFPA 2001. ΤΑ ΜΕΡΗ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ ΠΡΕΠΕΙ ΝΑ ΠΡΟΜΗΘΕΥΟΝΤΑΙ ΜΕ
ΑΝΤΙΣΕΙΣΜΙΚΗ ΠΡΟΣΤΑΣΙΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟ MSS SP-127. ΟΙ ΣΩΛΗΝΩΣΕΙΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΤΟΥΣ ΤΕΛΕΙΩΜΕΝΟΥΣ ΧΩΡΟΥΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΚΡΥΜΜΕΝΟΙ. ΠΑΡΕΧΕΤΕ ΕΚΤΟΝΩΤΕΣ ΟΠΩΣ ΧΡΕΙΑΖΕΤΑΙ ΓΙΑ
ΑΠΟΦΥΓΗ ΥΠΕΡΣΥΜΠΙΕΣΗΣ ΚΑΤΑ ΤΗ ΔΙΑΡΚΕΙΑ ΕΚΚΕΝΩΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ.
11.
NFPA 101 - 2018 EDITION, LIFE SAFETY CODE.
NFPA 101 - ΕΚΔΟΣΗ 2018, ΚΩΔΙΚΑΣ ΑΣΦΑΛΕΙΑΣ ΖΩΗΣ
NFPA 291 - 2019 EDITION, RECOMMENDED PRACTICE FOR FIRE HYDRANT TESTING AND
MARKING OF HYDRANTS.
NFPA 291 - ΕΚΔΟΣΗ 2019,ΣΥΝΙΣΤΩΜΕΝΗ ΠΡΑΚΤΙΚΗ ΓΙΑ ΤΗ ΔΟΚΙΜΗ ΚΑΙ ΤΗΝ ΣΗΜΑΝΣΗ ΤΩΝ
ΣΤΟΜΙΩΝ ΥΔΡΟΛΗΨΙΑΣ
NFPA 2001 - 2018 EDITION, STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS.
NFPA 2001 - ΕΚΔΟΣΗ 2018, ΠΡΟΤΥΠΟ ΓΙΑ ΤΑ ΣΥΣΤΗΜΑΤΑ ΚΑΘΑΡΩΝ ΠΥΡΟΣΒΕΣΤΙΚΩΝ
ΠΑΡΑΓΟΝΤΩΝ
NFPA 76 - 2020 EDITION, STANDARD FOR THE FIRE PROTECTION OF
TELECOMMUNICATIONS FACILITIES.
NFPA 76 - ΕΚΔΟΣΗ 2020, ΠΡΟΤΥΠΟ ΓΙΑ ΤΗΝ ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΕΓΚΑΤΑΣΤΑΣΕΩΝ
ΤΗΛΕΠΙΚΟΙΝΩΝΙΑΣ
SEAL ALL PENETRATIONS INTO THE PROTECTED SPACES. PROVIDE INSPECTION AND TESTING IN ACCORDANCE WITH NFPA 2001 AND SPECIFICATION 21 22 00.00 40. A ROOM INTEGRITY TEST MUST BE
COMPLETED FOR PRELIMINARY AND FINAL ACCEPTANCE TESTING.
ΣΦΡΑΓΙΣΤΕ ΟΛΕΣ ΤΙΣ ΔΙΑΤΡΗΣΕΙΣ ΣΕ ΠΡΟΣΤΑΤΕΥΜΕΝΟΥΣ ΧΩΡΟΥΣ. ΠΑΡΕΧΕΤΕ ΕΠΙΘΕΩΡΗΣΕΙΣ ΚΑΙ ΕΛΕΓΧΟΥΣ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 2001 ΚΑΙ ΤΗΝ ΠΡΟΔΙΑΓΡΑΦΗ 21 22 00.00 40. ΕΝΑΣ ΕΛΕΓΧΟΣ ΑΚΕΡΑΙΟΤΗΤΑΣ
ΔΩΜΑΤΙΟΥ ΠΡΕΠΕΙ ΝΑ ΓΙΝΕΤΑΙ ΓΙΑ ΑΡΧΙΚΗ ΚΑΙ ΤΕΛΙΚΗ ΔΟΚΙΜΗ ΑΠΟΔΟΧΗΣ.
17. PROVIDE HANGERS IN ACCORDANCE WITH NFPA 13 FOR SPRINKLER ARMOVERS GREATER THAN 300 MM.
ΠΑΡΕΧΕΤΕ ΣΤΗΡΙΓΜΑΤΑ ΣΥΜΦΩΝΑ ΜΕ ΤΟΝ NFPA 13 ΓΙΑ ΒΡΑΧΙΟΝΕΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΜΕΓΑΛΥΤΕΡΟΥΣ ΑΠΟ 300ΜΜ.
18. PROVIDE CONCEALED SPRINKLERS IN AREAS WITH CLEAN AGENT FIRE EXTINGUISHING SYSTEMS AND SUSPENDED CEILING SYSTEMS. PROVIDE UPRIGHT SPRINKLERS WITH UL LISTED SPRINKLER GUARDS IN AREAS WITH CLEAN AGENT FIRE EXTINGUISHING SYSTEMS AND NO SUSPENDED CEILINGS. SPRINKLERS MUST NOT BE INSTALLED DIRECTLY ABOVE ELECTRONIC OR SERVER RACKS. CENTER SPRINKLER IN CENTER OF CEILING
TILES.
ΠΑΡΕΧΕΤΕ ΚΡΥΦΟΥΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΣΕ ΠΕΡΙΟΧΕΣ ΜΕ ΣΥΣΤΗΜΑΤΑ ΠΥΡΟΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΣΥΣΤΗΜΑΤΑ ΨΕΥΔΟΡΟΦΩΝ.
ΠΑΡΕΧΕΤΕ ΟΡΘΙΟΥΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΜΕ ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΑΤΑΧΩΡΗΜΕΝΑ ΚΑΤΑ UL ΣΕ ΠΕΡΙΟΧΕΣ ΜΕ ΣΥΣΤΗΜΑΤΑ ΠΥΡΟΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΧΩΡΙΣ ΨΕΥΔΟΡΟΦΕΣ. ΟΙ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΕΓΚΑΘΙΣΤΑΝΤΑΙ ΠΑΝΩ ΑΠΟ ΗΛΕΚΤΡΟΝΙΚΑ ΣΥΣΤΗΜΑΤΑ Ή ΣΕΡΒΕΡ. ΚΕΝΤΡΑΡΕΤΕ ΤΟΝ ΚΑΤΑΙΟΝΗΤΗΡΑ ΣΤΟ ΚΕΝΤΡΟ ΤΟΥ ΠΛΑΚΑΚΙΟΥ ΨΕΥΔΟΡΟΦΗΣ.
WATER SUPPLY
ΠΑΡΟΧΗ ΝΕΡΟΥ
DESIGN WATER SUPPLY: SERVE THE AUTOMATIC FIRE SPRINKLER SYSTEMS FROM THE EXISTING COMBINATION BASE DOMESTIC AND FIRE WATER DISTRIBUTION SYSTEM. THE CONTRACTING OFFICER WILL PROVIDE THE MOST RECENT FIRE PUMP TEST DATA AS A BASIS FOR THE HYDRAULIC CALCULATIONS. HYDRAULIC CALCULATIONS MUST BE BASED UPON OPERATION OF A SINGLE FIRE PUMP RATED FOR 690 KPA AT 5,678 LPM LOCATED IN BUILDING 14. ASSUME 325 METERS OF 280
MM UNDERGROUND CPVC PIPING FROM THE POINT OF CONNECTION THE FIRE PUMP DISCHARGE.
ΣΧΕΔΙΑΣΜΟΣ ΠΑΡΟΧΗΣ ΝΕΡΟΥ: ΤΡΟΦΟΔΟΤΗΣΤΕ ΤΟ ΑΥΤΟΜΑΤΟ ΣΥΣΤΗΜΑ ΚΑΤΑΙΟΝΤΗΡΩΝ ΠΥΡΚΑΓΙΑΣ ΑΠΟ ΤΟ ΥΠΑΡΧΟΝ ΣΥΣΤΗΜΑ ΣΥΝΔΥΑΣΤΙΚΟ ΣΥΣΤΗΜΑ ΝΕΡΟΥ ΥΔΡΕΥΣΗΣ ΚΑΙ ΠΥΡΟΣΒΕΣΗΣ ΤΗΣ ΒΑΣΗΣ. Ο ΑΞΙΩΜΑΤΙΚΟΣ ΕΡΓΟΥ ΘΑ ΠΑΡΕΧΕΙ ΤΑ ΠΙΟ ΠΡΟΣΦΑΤΑ ΔΕΔΟΜΕΝΑ ΔΟΚΙΜΩΝ ΑΝΤΛΙΩΝ ΠΥΡΟΣΒΕΣΗΣ ΣΑΝ ΒΑΣΗ ΓΙΑ ΤΟΥΣ ΥΔΡΑΥΛΙΚΟΥΣ ΥΠΟΛΟΓΙΣΜΟΥΣ. ΟΙ ΥΔΡΑΥΛΙΚΟΙ ΥΠΟΛΟΓΙΣΜΟΙ ΠΡΕΠΕΙ ΝΑ ΒΑΣΙΖΟΝΤΑΙ ΠΑΝΩ ΣΤΗ ΛΕΙΤΟΥΡΓΕΙΑ ΜΙΑΣ ΑΝΤΛΙΑΣ ΠΥΡΟΣΒΕΣΗΣ ΡΥΘΜΙΣΜΕΝΗ ΓΙΑ 690KPA ΣΕ 5,678LPM ΠΟΥ ΒΡΙΣΚΕΤΑΙ ΣΤΟ ΚΤΙΡΙΟ 14. ΥΠΟΘΕΣΤΕ 325 ΜΕΤΡΑ ΜΕ 280ΜΜ ΥΠΟΓΕΙΑΣ CPVC ΣΩΛΗΝΩΣΗΣ ΑΠΟ ΤΟ ΣΗΜΕΙΟ ΣΥΝΔΕΣΗΣ ΜΕ ΤΗΝ ΕΞΟΔΟ ΤΗΣ ΑΝΤΛΙΑΣ
ΠΥΡΟΣΒΕΣΗΣ.
AIR ASPIRATING SMOKE DETECTION SYSTEM
ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΜΕ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ
PROVIDE AIR ASPIRATING SMOKE DETECTION (AASD) SYSTEM IN AREAS PROTECTED BY A CLEAN
AGENT FIRE EXTINGUISHING SYSTEM. DESIGN, INSTALL AND PROGRAM EACH AASD FOR VERY
EARLY WARNING SMOKE DETECTION IN ACCORDANCE WITH NFPA 76. PROGRAM EACH AASD FOR
ALERT, ALARM, AND CLEAN AGENT RELEASE AS SPECIFIED ON THE DRAWINGS. DESIGN AND
INSTALL THE PIPING NETWORK AND SAMPLING PORTS PER MANUFACTURER'S
RECOMMENDATIONS.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΜΕ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ (AASD) ΣΤΟΥΣ ΧΩΡΟΥΣ ΠΟΥ
ΠΡΟΣΤΑΤΕΥΟΝΤΑΙ ΑΠΟ ΣΥΣΤΗΜΑ ΚΑΤΑΣΒΕΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ. ΣΧΕΔΙΑΣΤΕ,
ΕΓΚΑΤΑΣΤΗΣΤΕ ΚΑΙ ΠΡΟΓΡΑΜΜΑΤΙΣΤΕ ΚΑΘΕ AASD ΓΙΑ ΠΟΛΥ ΕΓΚΑΙΡΗ ΕΙΔΟΠΟΙΗΣΗ ΑΝΙΧΝΕΥΣΗΣ
ΚΑΠΝΟΥ ΣΥΜΦΩΝΑ ΜΕ ΤΟ NFPA 76. ΠΡΟΓΡΑΜΜΑΤΙΣΤΕ ΚΑΘΕ AASD ΓΙΑ ΕΙΔΟΠΟΙΗΣΗ, ΣΥΝΑΓΕΡΜΟ
ΚΑΙ ΕΚΤΟΝΩΣΗ ΤΟΥ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΟΠΩΣ ΠΡΟΔΙΑΓΡΑΦΕΤΑΙ ΣΤΑ ΣΧΕΔΙΑ. ΣΧΕΔΙΑΣΤΕ ΚΑΙ
ΕΓΚΑΤΑΣΤΗΣΕ ΤΙΣ ΣΩΛΗΝΩΣΕΙΣ ΤΟΥ ΔΙΚΤΥΟΥ ΚΑΙ ΤΗΣ ΣΩΛΗΝΩΣΕΙΣ ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΣΥΜΦΩΝΑ
ΜΕ ΤΙΣ ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
1.
IN AREAS WITH SUSPENDED CEILINGS, INSTALL AIR- ASPIRATING DETECTION SYSTEM (AASD)
PIPING CONCEALED ABOVE CEILINGS AND UTILIZE MANUFACTURER'S CEILING MOUNTED
SAMPLING PORTS WITH CAPILARY TUBING.
ΣΤΟΥΣ ΧΩΡΟΥΣ ΜΕ ΨΕΥΣΔΟΡΟΦΕΣ ΕΓΚΑΤΑΣΤΗΣΤΕ ΤΙΣ ΣΩΛΗΝΩΣΕΙΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ
ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΜΕ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ (AASD) ΚΡΥΜΜΕΝΕΣ ΠΑΝΩ ΑΠΟ ΤΗΝ ΨΕΥΔΟΡΟΦΗ
ΚΑΙ ΧΡΗΣΙΜΟΠΟΙΗΣΤΕ ΤΙΣ ΣΤΗΡΙΖΟΜΕΝΕΣ ΣΤΗΝ ΟΡΟΦΗ ΣΩΛΗΝΩΣΕΙΣ ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΤΟΥ
ΚΑΤΑΣΚΕΥΑΣΤΗ
2.
IN ROOMS WITH RAISED ACCESS FLOORING THE AREA ABOVE AND BELOW THE RAISED
ACCESS FLOORING MUST BE DESIGNED AS SEPARATE AASD DETECTION ZONES. EACH ZONE
MUST BE PROVIDED WITH A SEPARATE AASD CONTROL PANEL.
ΣΤΑ ΔΩΜΑΤΙΑ ΜΕ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ Ο ΧΩΡΟΣ ΠΑΝΩ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ
ΔΑΠΕΔΟ ΠΡΕΠΕΙ ΝΑ ΣΧΕΔΙΑΖΟΝΤΑΙ ΣΑΝ ΞΕΧΩΡΙΣΤΕΣ AASD ΖΩΝΕΣ ΑΝΙΧΝΕΥΣΗΣ. ΚΑΘΕ ΖΩΝΗ
ΠΡΕΠΕΙ ΝΑ ΠΑΡΕΧΕΤΑΙ ΜΕ ΞΕΧΩΡΙΣΤΟ AASD ΠΙΝΑΚΑ ΕΛΕΓΧΟΥ.
3.
FCVA - FLOOR CONTROL VALVE
ASSEMBLY
ΜΟΝΑΔΑ ΒΑΝΑΣ ΕΛΕΓΧΟΥ
ΔΑΠΕΔΟΥ
BFP - BACKFLOW PREVENTER
ΕΞΑΡΤΗΜΑ
ΑΠΟΤΡΟΠΗΣ
ΑΝΤΙΡΡΟΗΣ
ESTIMATED CLEAN AGENT QUANTITY FK-5-1-12 ABOVE AND UNDERFLOOR PROTECTION
ΕΚΤΙΜΩΜΕΝΗ ΠΟΣΟΣΤΗΤΑ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ FK-5-1-12 ΠΑΝΩ ΚΑΙ ΥΠΟΔΑΠΕΔΙΑΣ ΠΡΟΣΤΑΣΙΑΣ
ROOM NAME
ΟΝΟΜΑΣΙΑ
ΔΩΜΑΤΙΟΥ
AREA
ΕΜΒΑΔΟ
HEIGHT
ΥΨΟΣ
ABOVE FLOOR
VOLUME
ΟΓΚΟΣ ΠΑΝΩ
ΑΠΟ ΔΑΠΕΔΟ
FLOODING FACTOR
ΠΑΡΑΓΟΝΤΑΣ
ΚΑΤΑΚΛΥΣΜΟΥ
MINIMUM REQUIRED AGENT
QUANTITY ABOVE FLOOR
ΕΛΑΧΙΣΤΗ ΠΟΣΟΤΗΤΑ
ΑΠΑΙΤΟΥΜΕΝΟΥ ΠΑΡΑΓΟΝΤΑ
ΠΑΝΩ ΑΠΟ ΔΑΠΕΔΟ
N6 EQUIPMENT
ROOM
Ν6 ΔΩΜΑΤΙΟ
ΕΞΟΠΛΙΣΜΟΥ
90 m² 3.0 m 275 m³
DESIGN
CONCENTRATION
ΣΥΓΚΕΝΤΡΩΣΗ
ΣΧΕΔΙΑΣΜΟΥ
5% 0.7322 kg/m³ 201 kg
147 m² 3.0 m 448 m³ 5% 327 kg
28 m² 3.0 m 85 m³ 5% 61 kg
FLEET-CYBER
EQUIP
ΕΞΟΠΛΙΣΜΟΥ
ΚΥΒΕΡΝΟ-
ΣΤΟΛΟΥ
1.0 m
1.0 m
1.0 m
0.7322 kg/m³
0.7322 kg/m³
NOTES:
ΣΗΜΕΙΩΣΕΙΣ:
NUMBER AND FILL WEIGHT OF CYLINDERS INDICATED IS FOR DIAGRAMATIC PURPOSES ONLY. ACTUAL QUANTITY OF AGENT AND NUMBER OF CYLINDERS, CYLINDER SIZE, AND MIN/MAX CYLINDER FILL
WEIGHT MUST BE BASED ON CONTRACTOR'S DESIGN.
Ο ΑΡΙΘΜΟΣ ΚΑΙ ΤΟ ΒΑΡΟΣ ΠΛΗΡΩΣΗΣ ΤΩΝ ΠΥΡΟΣΒΕΣΤΗΡΩΝ ΠΟΥ ΔΕΙΧΝΕΤΑΙ ΕΙΝΑΙ ΓΙΑ ΔΙΑΓΡΑΜΜΑΤΙΚΟΥΣ ΛΟΓΟΥΣ ΜΟΝΟ. Η ΠΡΑΓΜΑΤΙΚΗ ΠΟΣΟΤΗΤΑ ΤΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ Ο ΑΡΙΘΜΟΣ, ΤΟ ΜΕΓΕΘΟΣ ΚΑΙ ΤΟ ΜΕΓΙΣΤΟ/ΕΛΑΧΙΣΤΟ ΒΑΡΟΣ ΤΩΝ ΠΥΡΟΣΒΕΣΤΗΡΩΝ ΘΑ ΒΑΣΙΣΤΕΙ ΣΤΟΝ ΣΧΕΔΙΑΣΜΟ ΤΟΥ ΕΡΓΟΛΑΒΟΥ.
1.
N9 EQUIPMENT
ROOM
Ν9 ΔΩΜΑΤΙΟ
ΕΞΟΠΛΙΣΜΟΥ
BELOW FLOOR
VOLUME
ΟΓΚΟΣ ΚΑΤΩ
ΑΠΟ ΔΑΠΕΔΟ
MINIMUM REQUIRED AGENT
QUANTITY BELOW FLOOR
ΕΛΑΧΙΣΤΗ ΠΟΣΟΣΤΗΤΑ
ΠΑΡΑΓΟΝΤΑ ΚΑΤΩ
ΑΠΟ ΔΑΠΕΔΟ
88 m³
143 m³
27 m³
64 kg
105 kg
20 kg
ROOM NAME
ΟΝΟΜΑΣΙΑ
ΔΩΜΑΤΙΟΥ AREA
ΕΜΒΑΔΟ
HEIGHT
ΥΨΟΣ
ABOVE FLOOR
VOLUME
ΟΓΚΟΣ ΠΑΝΩ
ΑΠΟ ΔΑΠΕΔΟ
FLOODING FACTOR
ΠΑΡΑΓΟΝΤΑΣ
ΚΑΤΑΚΛΥΣΜΟΥ
MINIMUM REQUIRED AGENT
QUANTITY
ΕΛΑΧΙΣΤΗ ΑΠΑΙΤΟΥΜΕΝΗ
ΠΟΣΟΤΗΤΑ ΠΑΡΑΓΟΝΤΑ
DESIGN
CONCENTRATION
ΣΥΓΚΕΝΤΡΩΣΗ
ΣΧΕΔΙΑΣΜΟΥ
DEMARC 1 50 m² 4.0 m
UNDER FLOOR
DEPTH
ΒΑΘΟΣ ΚΑΤΩ
ΑΠΟ ΔΑΠΕΔΟ
199 m³ 5% 0.7322 kg/m³ 146 kg
DEMARC 2 42 m² 4.0 m 168 m³ 5% 0.7322 kg/m³ 122 kg
ELEC (133)
ΗΛΕΚΤ (133)
59 m² 4.0 m 237 m³ 5% 0.7322 kg/m³ 173 kg
NETWORK DIST
AREA
ΧΩΡΟΣ ΔΙΚΤΥΩΝ
57 m² 4.0 m 227 m³ 5% 0.7322 kg/m³ 173 kg
TR 1-1 17 m² 4.0 m 66.5 m³ 5% 0.7322 kg/m³ 49 kg
TR 1-G 17 m² 4.0 m 66 m³ 5% 0.7322 kg/m³ 49 kg
UPS (132) 28 m² 4.0 m 110 m³ 5% 0.7322 kg/m³ 81 kg
UPS (134) 30 m² 4.0 m 118 m³ 5% 0.7322 kg/m³ 87 kg
ESTIMATED CLEAN AGENT QUANTITY FK-5-1-12 ABOVE FLOOR PROTECTION
ΕΚΤΙΜΩΜΕΝΗ ΠΟΣΟΤΗΤΑ ΠΑΡΑΓΟΝΤΑ FK-5-1-13 ΠΡΟΣΤΑΣΙΑΣ ΠΑΝΩ ΑΠΟ ΔΑΠΕΔΟ
ROOM DIMENSIONS
ΔΙΑΣΤΑΣΕΙΣ ΔΩΜΑΤΙΟΥ
ROOM DIMENSIONS
ΔΙΑΣΤΑΣΕΙΣ ΔΩΜΑΤΙΟΥ
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:5
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-002
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
PR
O
TE
C
TI
O N
SY
M
BO
LS
AN
D
R
EQ
U
IR
EM
EN
TS
14089240
Π
ΥΡ
Ο Π
ΡΟ
ΣΤ
ΑΣ
ΙΑ
ΣΥ
Μ
Β Ο
ΛΑ
Κ
Α
ΙΑ
Π Α
ΙΤ
Η
ΣΕ
ΙΣ
DPS
DPS
FIRE SUPPRESSION SYMBOLS
ΣΥΜΒΟΛΑ ΚΑΤΑΣΤΟΛΗΣ ΠΥΡΚΑΓΙΑΣ
ELBOW UP
ΚΑΜΠΥΛΗ ΠΡΟΣ ΤΑ ΠΑΝΩ
ELBOW DOWN
ΚΑΜΠΥΛΗ ΠΡΟΣ ΤΑ ΚΑΤΩ
TEE UP
ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΠΑΝΩ
TEE DOWN
ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΚΑΤΩ
LATERAL UP
ΠΛΕΥΡΙΚΗ ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΠΑΝΩ
LATERAL DOWN
ΠΛΕΥΡΙΚΗ ΔΙΑΚΛΑΔΩΣΗ ΠΡΟΣ ΤΑ ΚΑΤΩ
CONCENTRIC REDUCER
ΟΜΟΚΕΝΤΡΗ ΑΛΛΑΓΗ ΔΙΑΤΟΜΗΣ
ECCENTRIC REDUCER
ΕΚΚΕΝΤΡΗ ΑΛΛΑΓΗ ΔΙΑΤΟΜΗΣ
UNION
ΣΥΝΔΕΣΜΟΣ
ELBOW, 90 DEGREE
ΚΑΜΠΥΛΗ 90 ΜΟΙΡΩΝ
TEE
ΤΑΥ
ELBOW, 45 DEGREE
ΚΑΜΠΥΛΗ 45 ΜΟΙΡΩΝ
AREAS OF APPLICATION
LIGHT HAZARD
FIRE SUPPRESSION SYSTEM REQUIREMENTS
ΑΠΑΙΤΗΣΕΙΣ ΣΥΣΤΗΜΑΤΟΣ ΚΑΤΑΣΒΕΣΗΣ ΠΥΡΚΑΓΙΑΣ
LH
GATE
ΣΥΡΤΑΡΩΤΗ
OR
BUTTERFLY
ΠΕΤΑΛΟΥΔΑΣ
OR GLOBE
ΕΔΡΑΣ
OR BALL
ΣΦΑΙΡΙΚΗ
OR SWING CHECK
ΕΛΕΓΧΟΥ ΡΟΗΣ
ΧΑΜΗΛΟΣ ΚΙΝΔΥΝΟΣ
CLEAN AGENT CYLINDER
ΠΥΡΟΣΒΕΣΤΗΡΑΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ
ORDINARY HAZARD OH
ΜΕΣΑΙΟΣ ΚΙΝΔΥΝΟΣ
HAZARD
CLASSIFICATION
ΚΑΤΗΓΟΡΙΑ
ΕΠΙΚΙΝΔΥΝΟΤΗΤΑΣ
ΠΕΡΙΟΧΗ ΕΦΑΡΜΟΓΗΣ
RESTROOMS, OFFICES, CORRIDORS,
BREAKROOMS, STAIRS AND SIMILAR
OCCUPANCIES
ΛΟΥΤΡΑ, ΓΡΑΦΕΙΑ, ΔΙΑΔΡΟΜΟΙ,
ΔΩΜΑΤΙΑ ΔΙΑΛΕΙΜΜΑΤΩΝ, ΣΚΑΛΕΣ
ΚΑΙ ΠΑΡΟΜΟΙΕΣ ΧΡΗΣΕΙΣ
COMM ROOMS, MECHANICAL /
ELECTRICAL ROOMS, TR ROOMS,
JANITORS ROOMS, RECEIVING,
LOADING AND SIMILAR
OCCUPANCIES
ΔΩΜΑΤΙΑ ΥΠΟΛΟΓΙΣΤΩΝ,
ΜΗΧΑΝΟΣΤΑΣΙΑ
/ΗΛΕΚΤΡΟΣΤΑΣΙΑ, ΔΩΜΑΤΙΑ ΕΠΙΣΤΑΤΗ
ΥΠΟΔΟΧΗΣ ΚΑΙ ΠΑΡΟΜΟΙΕΣ ΧΡΗΣΕΙΣ
SPRINKLER DESIGN DENSITY
ΠΥΚΝΟΤΗΤΑ ΣΧΕΔΙΑΣΜΟΥ
ΚΑΤΑΙΟΝΗΤΗΡΑ
4 (MM/MIN)/M² 8 (MM/MIN)/M²
DISCHARGE TIME
ΧΡΟΝΟΣ ΕΚΚΕΝΩΣΗΣ
60 MINUTES
60 ΛΕΠΤΑ
60 MINUTES
60 ΛΕΠΤΑ
SPRINKLER TYPE
ΕΙΔΟΣ ΚΑΤΑΙΟΝΗΤΗΡΑ
QUICK RESPONSE
ΑΜΕΣΗΣ ΑΠΟΚΡΙΣΗΣ
QUICK RESPONSE
ΑΜΕΣΗΣ ΑΠΟΚΡΙΣΗΣ
DESCRIPTION
ΠΕΡΙΓΡΑΦΗ
MAXIMUM PROTECTION AREA
PER SPRINKLER
ΜΕΓΙΣΤΗ ΠΕΡΙΟΧΗ ΚΑΛΥΨΗΣ
ΑΝΑ ΚΑΤΑΙΟΝΗΤΗΡΑ
20.9 M² 12.1 M²
HOSE STREAM ALLOWANCE
ΑΝΟΧΗ ΡΟΗΣ ΜΑΝΙΚΑΣ
950 LPM 950 LPM
DESIGN AREA
ΠΕΡΙΟΧΗ ΣΧΕΔΙΑΣΜΟΥ
140 M² 230 M²
TEMPERATURE RATING OF
SPRINKLERS
ΤΑΞΙΝΟΜΗΣΗ ΘΕΡΜΟΚΡΑΣΙΑΣ
ΚΑΤΑΙΟΝΗΤΗΡΑ
ORDINARY (71°C)
ΣΥΝΗΘΗΣ (71°C)
ORDINARY (71°C)
ΣΥΝΗΘΗΣ (71°C)
MAXIMUM SPACING BETWEEN
SPRINKLERS
ΜΕΓΙΣΤΗ ΑΠΟΣΤΑΣΗ ΜΕΤΑΞΥ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ
4.6 M 4.6 M
MAXIMUM PROTECTION AREA
PER RISER
ΜΕΓΙΣΤΗ ΠΕΡΙΟΧΗ ΚΑΛΥΨΗΣ
ΑΝΑ ΚΑΤΑΚΟΡΥΦΟ
4830 M² 4830 M²
SPRINKLER K-FACTOR
ΣΥΝΤΕΛΕΣΤΗΣ Κ
ΚΑΤΑΙΟΝΗΤΗΡΑ
80 115
PIPE "C" FACTOR
ΣΥΝΤΕΛΕΣΤΗΣ C ΣΩΛΗΝΑ
120 120
FIRE HYDRANT FLOW TEST DATA
ΔΕΔΟΜΕΝΑ ΔΟΚΙΜΩΝ ΡΟΗΣ ΠΡΥΣΒΕΣΤΙΚΩΝ ΚΡΟΥΝΩΝ
STATIC PRESSURE
ΣΤΑΤΙΚΗ ΠΙΕΣΗ
450 KPA
RESIDUAL PRESSURE
ΥΠΟΛΕΙΠΟΜΕΝΗ ΠΙΕΣΗ
220 KPA
FLOW AT RESIDUAL
ΡΟΗ ΣΤΗΝ ΥΠΟΛΕΙΠΟΜΕΝΗ
3,300 LPM
FLOW AT 138 KPA
ΡΟΗ ΣΤΑ 138 ΚΡΑ
3,903 LPM
DATE OF TEST
ΗΜΕΡΟΜΗΝΙΑ ΔΟΚΙΜΗΣ
09.10.2019 10/09/2019
TIME OF TEST
ΩΡΑ ΔΟΚΙΜΗΣ
TEST PERFORMED BY
Η ΔΟΚΙΜΗ
ΠΡΑΓΜΑΤΟΠΟΙΗΘΗΚΕ ΑΠΟ
BASE CIVIL ENGINEERING
ΠΟΛΙΤΙΚΟΣ ΜΗΧΑΝΙΚΟΣ ΤΗΣ
ΒΑΣΗΣ
TEST WTINESSED BY
ΣΤΗ ΔΟΚΙΜΗ ΠΑΡΕΥΡΕΘΗΚΕ
JACOBS
PD
D
R
LA
SV
CA
A
CLEAN AGENT PRE-DISCHARGE AUDIO/VISUAL ALARM
ΟΠΤΙΚΟ/ΑΚΟΥΣΤΙΚΟΣ ΣΥΝΑΓΕΡΜΟΣ ΠΡΟ-ΕΚΚΕΝΩΣΗΣ
ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT POST-DISCHARGE AUDIO/VISUAL ALARM
ΟΠΤΙΚΟ/ΑΚΟΥΣΤΙΚΟΣ ΣΥΝΑΓΕΡΜΟΣ ΜΕΤΑ-ΕΚΚΕΝΩΣΗΣ
ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ
RELAY MODULE
ΜΟΝΑΔΑ ΡΕΛΕ
CLEAN AGENT CYLINDER LOW PRESSURE SWITCH
ΔΙΑΚΟΠΤΗΣ ΧΑΜΗΛΗΣ ΠΙΕΣΗΣ ΠΥΡΟΣΒΕΣΤΗΡΑ ΚΑΘΑΡΟΥ
ΠΑΡΑΓΟΝΤΑ
SOLENOID VALVE
ΒΑΝΑ ΣΩΛΗΝΟΕΙΔΟΥΣ ΠΗΝΙΟΥ
CLEAN AGENT MANUAL DISCHARGE
ΧΕΙΡΟΚΙΝΗΤΗ ΕΚΚΕΝΩΣΗ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT ABORT STATION
ΣΤΑΘΜΟΣ ΔΙΑΚΟΠΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ
EPO EMERGENCY POWER OFF BUTTON
ΚΟΥΜΠΙ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗΣ ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ
360 DEGREE NOZZLE
ΑΚΡΟΦΥΣΙΟ 360 ΜΟΙΡΩΝ
180 DEGREE NOZZLE
ΑΚΡΟΦΥΣΙΟ 180 ΜΟΙΡΩΝ
SPD
SURGE PROTECTIVE DEVICE
ΣΥΣΚΕΥΗ ΠΡΟΣΤΑΣΙΑΣ ΥΠΕΡΤΑΣΗΣ
AASD
AIR ASPIRATING SMOKE DETECTION SYSTEM
CONTROL PANEL
ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΣΥΣΤΗΜΑΤΟΣ ΑΝΙΧΝΕΥΣΗΣ
ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗ ΑΕΡΑ
CLEAN AGENT RELEASING PANEL
ΠΙΝΑΚΑΣ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑCARP
IM INPUT MONITOR MODULE
ΜΟΝΑΔΑ ΟΘΟΝΗΣ ΚΑΤΑΧΩΡΗΣΕΩΝ
CM CONTROL MODULE
ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ
A
2 3 4 5 6 7 8
B
C
D
ELEC
UPS
MECH
DEMARC 2
IT LOGISTICS
RECYCLE
RECEIVING
BUNK
QUARTER DECK
ELEV
LOBBY
LH
OH
LH
LH
OH
OH
OH
OH
WOMENS
LH
A1 F-301
STAIR 1
NIPR CAFE
N6 CONF
N6
N6 C3P
113N6 ISSM
114N6 ID
N6 MAINTENANCE
BREAK
N6 EQUIPMENT
ROOM
UPS
MENS
CORRIDOR
VEST
VEST
OH
OH
OH
LH
LH OH
OH
OH
LH
LH
LH
LH
OH
LH
LH
LH
LH
LH
OH
LH
JAN
OH
A
AA
S
D C
A R
P
CA
CLOSET
DEMARC 1
141 SIPR CAFE
TR G-1
N6 STOR
MOTHERS
N6 MAINT
OH
OH
OH
LH
PD
D
LA
LA
LA
SV
SV
A CAAASD CARP PD D
A CA
D
P D
AASDCARP
A CA
AASD CARP
D
P D
A C
A
D
PD
AASDCARP
LASV LASV
LA LASV LASV
A CAPD
AA
S
D C
A R
P
A CA
P D
AASD
CARP
LASV
LA
LA
AA
S
D
D
WP
m
1 m
C M
C M
C M
5 5 5 5
7 7 7 7
88 8 8
C M
C M
C M
C M
C M
C M
C M
C M
CM CM
CMCM
CM
C M
C M
D
9 9
1 1
2 2
OH
FIRE PROT
CLEAN AGENT
CYLINDER
ΠΥΡΟΣΒΕΣΤΗΡΑΣ
ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT
CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑΣ
(ΕΣ) ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΑΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT
CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑΣ
(ΕΣ) ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΑΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT
CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑΣ(ΕΣ)
ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT
CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑΣ(ΕΣ)
ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT
CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑ(Ε)Σ
ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ
CLEAN AGENT CYLINDER(S)
ΠΥΡΟΣΒΕΣΤΗΡΑ(Ε)Σ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
SV IM
IM IM10
SPRINKLER DESIGN CRITERIA
ΚΡΙΤΗΡΙΑ ΣΧΕΔΙΑΣΜΟΥ ΚΑΤΑΙΟΝΗΤΗΡΩΝ
HAZARD
CLASSIFICATION
ΚΑΤΗΓΟΡΙΑ
ΚΙΝΔΥΝΟΥ
DESIGN
REQUIREMENTS
ΑΠΑΙΤΗΣΕΙΣ
ΣΧΕΔΙΑΣΜΟΥ
DURATION
OF SUPPLY
ΔΙΑΡΚΕΙΑ
ΠΑΡΟΧΗΣ
SPRINKLER
SPACING MAX
ΜΕΓΙΣΤΗ ΑΠΟΣΤΑΣΗ
ΚΑΤ/ΡΩΝ
REQUIRED
SPRINKLER
ΑΠΙΤΟΥΜΕΝΟΙ
ΚΑΤΑΙΟΝΗΤΗΡΕΣ
LH LIGHT
ΧΑΜΗΛΟΣ
ORDINARY
ΜΕΣΑΙΟΣ
4 MM/MIN OVER MOST
REMOTE 140 M² PLUS 950
LPM HOSE STREAM
4MM/MIN ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ 140M²
ΣΥΝ 950GPM ΡΟΗ
ΜΑΝΙΚΑΣ
8 MM/MIN OVER MOST
REMOTE 230 M² PLUS 950
LPM HOSE STREAM
8MM/MIN ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ 230M²
ΣΥΝ 950GPM ΡΟΗ ΜΑΝΙΚΑΣ
60 MIN
60 MIN
4.6 M
4.6 M
ORDINARY, QUICK
RESPONSE, K=80
ΣΥΝΗΘΗΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ, Κ=80
ORDINARY, QUICK
RESPONSE, K=115
ΣΥΝΗΘΗΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ, Κ=115
OH
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:0
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-101
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
PR
O
TE
C
TI
O N
PL
AN
-G R
O U
N D
FL
O
O R
14089241
Π
ΥΡ
Ο Π
ΡΟ
ΣΤ
ΑΣ
ΙΑ
-Ι
ΣΟ
ΓΕ
ΙΟ
DPS
DPS
1 : 100A1
FIRE PROTECTION GROUND FLOOR/
ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΙΣΟΓΕΙΟ
PLAN NORTH
1 CONTROL MODULE FOR EPO SHUTDOWN.
ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΓΙΑ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΕΡΟ.
2 PROVIDE CONTROL MODULES FOR CRAHU SHUTDOWN.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ CRAHU.
3 PROVIDE VERY EARLY WARNING SMOKE DETECTION SYSTEM AND
CLEAN AGENT (FK-5-1-12) FIRE EXTINGUISHING SYSTEM ABOVE AND
BELOW THE RAISED ACCESS FLOOR.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΚΑΙ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ (FK-5-1-12) ΠΑΝΩ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟ
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ.
4 PROVIDE CONCEALED PENDENT SPRINKLERS IN ALL ELECTRONIC
EQUIPMENT AREAS WHERE SUSPENDED CEILING SYSTEM IS
INSTALLED. SPRINKLERS MUST NOT BE LOCATED DIRECTLY OVER
ELECTRICAL EQUIPMENT, SERVER RACKS, OR MAJOR ELECTRICAL
COMPONENTS.
ΠΑΡΕΧΕΤΕ ΚΡΕΜΑΣΤΟΥΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΚΡΕΜΑΣΤΟΥ ΤΥΠΟΥ ΣΕ
ΟΛΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ ΜΕ ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ ΟΠΟΥ
ΤΟΠΟΘΕΤΕΙΤΑΙ ΣΥΣΤΗΜΑ ΨΕΥΔΟΡΟΦΗΣ. ΟΙ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ
ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΚΑΤΕΥΘΕΙΑΝ ΠΑΝΩ ΑΠΟ
ΗΛΕΚΤΡΟΛΟΓΙΚΟ ΕΞΟΠΛΙΣΜΟ, ΒΑΣΕΙΣ ΣΕΡΒΕΡ Ή ΜΕΓΑΛΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΕΞΑΡΤΗΜΑΤΑ.
5 PROVIDE UPRIGHT SPRINKLERS WITH LISTED SPRINKLER GUARDS
IN ALL ELECTRONIC EQUIPMENT AREAS WITHOUT FINISHED
CEILINGS. SPRINKLERS MUST NOT BE LOCATED DIRECTLY OVER
ELECTRICAL EQUIPMENT, SERVER RACKS, OR MAJOR ELECTRICAL
COMPONENTS.
ΠΑΡΕΧΕΤΕ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΟΡΘΙΟΥ ΤΥΠΟΥ ΜΕ ΚΑΤΑΧΩΡΗΜΕΝΑ
ΚΑΤΑ UL ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΣΕ ΟΛΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ ΜΕ
ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ ΧΩΡΙΣ ΤΕΛΕΙΩΜΕΝΕΣ ΟΡΟΦΕΣ. ΟΙ
ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΚΑΤΕΥΘΕΙΑΝ
ΠΑΝΩ ΑΠΟ ΗΛΕΚΤΡΙΚΟ ΕΞΟΠΛΙΣΜΟ, ΒΑΣΕΙΣ ΣΕΡΒΕΡ Ή ΜΕΓΑΛΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΕΞΑΡΤΗΜΑΤΑ.
6 PROVIDE AIR-ASPIRATING VERY EARLY WARNING SMOKE
DETECTION SYSTEM FOR THE ACTIVATION OF THE CLEAN AGENT
SYSTEMS PROTECTING THE SPACE ABOVE AND BELOW THE RAISED
ACCESS FLOOR WITHIN THE AREA. PROVIDE A SEPARATE AIR
ASPIRATING DETECTION PANEL FOR ABOVE THE RAISED FLOOR
AND ONE FOR BELOW THE RAISED FLOOR. CONTRACTOR
RESPONSIBLE FOR PIPE NETWORK AND SAMPLING PORT
LOCATIONS TO ENSURE PROPER FUNCTION OF SYSTEM PER
MANUFACTURER'S SPECIFICATIONS.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΠΡΟΕΙΔΟΠΟΙΗΣΗΣ ΓΙΑ ΤΗΝ ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ
ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΠΟΥ ΠΡΟΣΤΑΤΕΥΟΥΝ ΤΟΝ
ΧΩΡΟ ΠΑΝΩ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΕΝΤΟΣ ΤΟΥ
ΧΩΡΟΥ. ΠΑΡΕΧΕΤ ΞΕΧΩΡΙΣΤΟ ΠΙΝΑΚΑ ΑΝΙΧΝΕΥΣΗΣ ΑΝΑΡΡΟΦΗΣΗΣ
ΑΕΡΑ ΓΙΑ ΠΑΝΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΚΑΙ ΕΝΑΝ ΓΙΑ ΚΑΤΩ
ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ. Ο ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ
ΓΙΑ ΤΟ ΔΙΚΤΥΟ ΣΩΛΗΝΩΣΕΩΝ ΚΑΙ ΤΙΣ ΘΕΣΕΣ ΤΩΝ ΣΩΛΗΝΩΝ
ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΓΙΑ ΝΑ ΔΙΑΣΦΑΛΙΣΕΙ ΤΗΝ ΚΑΤΑΛΛΗΛΗ ΛΕΙΤΟΥΡΓΙΑ
ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
7 PROVIDE AIR-ASPIRATING VERY EARLY WARNING SMOKE
DETECTION SYSTEM FOR THE ACTIVATION OF THE CLEAN AGENT
SYSTEM PROTECTING THE SPACE. CONTRACTOR RESPONSIBLE
FOR PIPE NETWORK AND SAMPLING PORT LOCATIONS TO ENSURE
PROPER FUNCTION OF SYSTEM PER MANUFACTURER'S
SPECIFICATIONS.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΓΙΑ ΤΗΝ ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΠΟΥ ΠΡΟΣΤΑΤΕΥΕΙ ΤΟΝ ΧΩΡΟ.
Ο ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΟ ΔΙΚΤΥΟ ΣΩΛΗΝΩΣΕΩΝ ΚΑΙ
ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ ΣΩΛΗΝΩΝ ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΓΙΑ ΝΑ ΔΙΑΣΦΑΛΙΣΕΙ
ΤΗΝ ΚΑΤΑΛΛΗΛΗ ΛΕΙΤΟΥΡΓΙΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ
ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
8 PROVIDE VERY EARLY WARNING SMOKE DETECTION SYSTEM AND
CLEAN AGENT (FK-5-1-12) FIRE EXTINGUISHING SYSTEM IN THE
PROTECTED AREA.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΠΟΛΥ ΕΓΚΑΙΡΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ ΚΑΙ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ
(FK-5-1-12) ΣΤΗΝ ΠΡΟΣΤΑΤΕΥΟΜΕΝΗ ΠΕΡΙΟΧΗ.
9 PROVIDE CONTROL MODULES FOR FIRE/SMOKE DAMPERS.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΤΑ ΔΙΑΦΡΑΓΜΑΤΑ
ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ.
10 MONITOR EPO SHUTDOWN FROM ROOM CONTROL MODULES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗΣ EPO ΑΠΟ ΜΟΝΑΔΕΣ
ΕΛΕΓΧΟΥ ΔΩΜΑΤΙΟΥ
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F-501 KAI F-502 ΓΙΑ ΤΟΝ ΚΑΤΑΚΟΡΥΦΟ
ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
B. REFER TO SHEETS F503 & F504 FOR CLEAN AGENT SYSTEM RISERS
AND DETAILS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F503 & F504 ΓΙΑ ΚΑΤΑΚΟΡΥΦΟΥΣ
ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
C. CONTROL MODULES ASSOCIATED WITH EMEREGENCY POWER OFF
(EPO) MUST BE MONITORED BY THE CLEAN AGENT RELEASING
PANEL. REFER TO ELECTRICAL POWER PLANS FOR COORDINATION.
ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ ΜΕ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ
ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ (EPO) ΠΡΕΠΕΙ ΝΑ ΕΛΕΓΧΟΝΤΑΙ ΑΠΟ ΤΟΝ
ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΘΕΙΤΕ
ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ.
D. REFER TO MECHANICAL PLANS FOR LOCATIONS OF FIRE/SMOKE
DAMPERS AND COMPUTER ROOM AIR CONDITIONING UNITS
(CRAHU).
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ
ΔΙΑΦΡΑΓΜΑΤΑ ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ ΚΑΙ ΤΙΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΤΙΣΜΟΥ
ΤΟΥ ΔΩΜΑΤΙΟΥ Η/Υ (CRAHU)
0 100 200
SCALE 1 : 100
200 MM FIRE LINE
200 ΜΜ ΓΡΑΜΜΗ ΠΥΡΟΣΒΕΣΗΣ
BFPFDC
BFP TEST
HEADER
ΚΕΦΑΛΗ
ΔΟΚΙΜΩΝ BFP
MAIN DRAIN
ΚΕΝΤΡΙΚΗ
ΑΠΟΣΤΡΑΓΓΙΣΗ
FCVA
FCVA
FCVA
FCVA
FCVA FCVA
FCVA
2 3 4 5 6 7 8
B
C
D
N9 MAINTENANCE
STAIR 2
SEC MNGR
MECH
TR 1-1
OH
OH
OH
OH
LH
OHLH LH
LH
LHLHLH
LH
LH
ELEC
N00 COMMAND
TECH DIR
UNCLASS CONF
NETWORK DIST
AREA
STAIR 1
LNSC DIR
SN ENLIST
FIN ANLS
ELEV
LH
LH
LH
LH
WOMENS
MENS
BREAK
JAN
OH
OH
N3 LNSC
LH
OH
N9 OPEN OFFICE
N9 BCO
LNSC ANALYSIS
1 2
STORAGE
A C
A P
D
D
AA
S
D C
A R
P
A CA
CARP
P D
AASD
7CM CM
CM CM
CM
D
8 9
SV
LA
SV
LA 10
SPRINKLER DESIGN CRITERIA
ΚΡΙΤΗΡΙΑ ΣΧΕΔΙΑΣΜΟΥ ΚΑΤΑΙΟΝΗΤΗΤΡΩΝ
HAZARD
CLASSIFICATION
ΚΑΤΗΓΟΡΙΑ
ΚΙΝΔΥΝΟΥ
DESIGN
REQUIREMENTS
ΑΠΑΙΤΗΣΕΙΣ
ΣΧΕΔΙΑΣΜΟΥ
DURATION
OF SUPPLY
ΔΙΑΡΚΕΙΑ
ΠΑΡΟΧΗΣ
SPRINKLER
SPACING MAX
ΜΕΓΙΣΤΗ
ΑΠΟΣΤΑΣΗ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ
REQUIRED
SPRINKLER
ΑΠΑΙΤΟΥΜΕΝΟΙ
ΚΑΤΑΙΟΝΗΤΗΡΕΣ
LH LIGHT
ΧΑΜΗΛΟΣ
ORDINARY
ΜΕΣΑΙΟΣ
4 MM/MIN OVER MOST
REMOTE 140 M² PLUS 950
LPM HOSE STREAM
4ΜΜ/ΜΙΝ ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ ΣΥΝ
950 LPM ΡΟΗ ΜΑΝΙΚΑΣ
8 MM/MIN OVER MOST
REMOTE 230 M² PLUS 950
LPM HOSE STREAM
8 ΜΜ/ΜΙΝ ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ 230 M²
ΣΥΝ 950 LPM ΡΟΗ ΜΑΝΙΚΑΣ
60 MIN
60 MIN
4.6 M
4.6 M
ORDINARY, QUICK
RESPONSE, K=80
ΣΥΝΗΘΕΙΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ Κ=80
ORDINARY, QUICK
RESPONSE, K=115
ΣΥΝΗΘΕΙΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ, Κ=115
OH
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:1
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-102
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
PR
O
TE
C
TI
O N
PL
AN
-F
IR
ST
FL
O O
R
14089242
Π
ΥΡ
Ο Π
ΡΟ
ΣΤ
ΑΣ
ΙΑ
-Π Ρ
Ω
ΤΟ
Σ Ο
Ρ Ο
Φ Ο
Σ
DPS
DPS
1 : 100A1
FIRE PROTECTION FIRST FLOOR /
ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΠΡΩΤΟΣ ΟΡΟΦΟΣ
1 150 MM UP TO SERVE SECOND FLOOR.
150ΜΜ ΠΡΟΣ ΤΑ ΠΑΝΩ ΓΙΑ ΕΞΥΠΗΡΕΤΗΣΗ ΤΟΥ 2ΟΥ ΟΡΟΦΟΥ.
2 150 MM FLOOR CONTROL VALVE FOR FIRST FLOOR.
150ΜΜ ΒΑΝΑ ΕΛΕΓΧΟΥ ΟΡΟΦΟΥ ΓΙΑ ΤΟΝ 1Ο ΟΡΟΦΟ.
3 ZONE CONTROL VALVE WITH WATER FLOW SWITCH, CHECK
VALVE, AND BUTTERFLY VALVE TAMPER SWITCH.
ΒΑΝΑ ΕΛΕΓΧΟΥ ΖΩΝΗΣ ΜΕ ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ, ΒΑΝΑ
ΕΛΕΓΧΟΥ ΚΑΙ ΒΑΝΑ ΠΕΤΑΛΟΥΔΑΣ ΜΕ ΑΝΑΓΓΕΛΙΑ ΘΕΣΗΣ ΔΙΑΚΟΠΤΗ
4 PROVIDE CONCEALED PENDENT SPRINKLERS IN ALL ELECTRONIC
EQUIPMENT AREAS WHERE SUSPENDED CEILING SYSTEM IS
INSTALLED. SPRINKLERS MUST NOT BE LOCATED DIRECTLY OVER
ELECTRICAL EQUIPMENT, SERVER RACKS, OR MAJOR ELECTRICAL
COMPONENTS.
ΠΑΡΕΧΕΤΕ ΚΡΕΜΑΣΤΟΥΣ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΚΡΕΜΑΣΤΟΥ ΤΥΠΟΥ ΣΕ
ΟΛΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ ΜΕ ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ ΟΠΟΥ
ΤΟΠΟΘΕΤΕΙΤΑΙ ΣΥΣΤΗΜΑ ΨΕΥΔΟΡΟΦΗΣ. ΟΙ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ
ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΚΑΤΕΥΘΕΙΑΝ ΠΑΝΩ ΑΠΟ
ΗΛΕΚΤΡΟΛΟΓΙΚΟ ΕΞΟΠΛΙΣΜΟ, ΒΑΣΕΙΣ ΣΕΡΒΕΡ Ή ΜΕΓΑΛΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΕΞΑΡΤΗΜΑΤΑ.
5 PROVIDE UPRIGHT SPRINKLERS WITH LISTED SPRINKLER GUARDS
IN ALL ELECTRONIC EQUIPMENT AREAS WITHOUT FINISHED
CEILINGS. SPRINKLERS MUST NOT BE LOCATED DIRECTLY OVER
ELECTRICAL EQUIPMENT, SERVER RACKS, OR MAJOR ELECTRICAL
COMPONENTS.
ΠΑΡΕΧΕΤΕ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΟΡΘΙΟΥ ΤΥΠΟΥ ΜΕ ΚΑΤΑΧΩΡΗΜΕΝΑ
ΚΑΤΑ UL ΠΡΟΣΤΑΤΕΥΤΙΚΑ ΣΕ ΟΛΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ ΜΕ
ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ ΧΩΡΙΣ ΤΕΛΕΙΩΜΕΝΕΣ ΟΡΟΦΕΣ. ΟΙ
ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΔΕΝ ΠΡΕΠΕΙ ΝΑ ΤΟΠΟΘΕΤΟΥΝΤΑΙ ΚΑΤΕΥΘΕΙΑΝ
ΠΑΝΩ ΑΠΟ ΗΛΕΚΤΡΙΚΟ ΕΞΟΠΛΙΣΜΟ, ΒΑΣΕΙΣ ΣΕΡΒΕΡ Ή ΜΕΓΑΛΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΕΞΑΡΤΗΜΑΤΑ.
6 PROVIDE AIR-ASPIRATING VERY EARLY WARNING SMOKE
DETECTION SYSTEM FOR THE ACTIVATION OF THE CLEAN AGENT
SYSTEM PROTECTING THE SPACE. CONTRACTOR RESPONSIBLE
FOR PIPE NETWORK AND SAMPLING PORT LOCATIONS TO ENSURE
PROPER FUNCTION OF SYSTEM PER MANUFACTURER'S
SPECIFICATIONS.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΓΙΑ ΤΗΝ ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΟΥ
ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΠΟΥ ΠΡΟΣΤΑΤΕΥΕΙ ΤΟΝ
ΧΩΡΟ. Ο ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΟ ΔΙΚΤΥΟ
ΣΩΛΗΝΩΣΕΩΝ ΚΑΙ ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ ΣΩΛΗΝΩΝ ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΓΙΑ
ΝΑ ΔΙΑΣΦΑΛΙΣΕΙ ΤΗΝ ΚΑΤΑΛΛΗΛΗ ΛΕΙΤΟΥΡΓΙΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ
ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
7 PROVIDE VERY EARLY WARNING SMOKE DETECTION SYSTEM AND
CLEAN AGENT (FK-5-1-12) FIRE EXTINGUISHING SYSTEM IN THE
PROTECTED AREA.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΠΟΛΥ ΕΓΚΑΙΡΗΣ
ΕΙΔΟΠΟΙΗΣΗΣ ΚΑΙ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ (FK-5-1-12) ΣΤΗΝ ΠΡΟΣΤΑΤΕΥΟΜΕΝΗ ΠΕΡΙΟΧΗ.
8 PROVIDE CONTROL MODULES FOR CRAHU SHUTDOWN.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ CRAHU
9 PROVIDE CONTROL MODULES FOR FIRE/SMOKE DAMPERS.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΤΑ ΔΙΑΦΡΑΓΜΑΤΑ
ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ.
10 LOCATION OF CLEAN AGENT CYLINDER(S).
ΘΕΣΗ ΠΥΡΟΣΒΕΣΤΗΡΑ(ΩΝ) ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ.
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F-501 KAI F-502 ΓΙΑ ΤΟΝ ΚΑΤΑΚΟΡΥΦΟ
ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
B. REFER TO SHEETS F503 & F504 FOR CLEAN AGENT SYSTEM RISERS
AND DETAILS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F503 & F504 ΓΙΑ ΚΑΤΑΚΟΡΥΦΟΥΣ
ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
C. CONTROL MODULES ASSOCIATED WITH EMEREGENCY POWER OFF
(EPO) MUST BE MONITORED BY THE CLEAN AGENT RELEASING
PANEL. REFER TO ELECTRICAL POWER PLANS FOR COORDINATION.
ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ ΜΕ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ
ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ (EPO) ΠΡΕΠΕΙ ΝΑ ΕΛΕΓΧΟΝΤΑΙ ΑΠΟ ΤΟΝ
ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΘΕΙΤΕ
ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ.
D. REFER TO MECHANICAL PLANS FOR LOCATIONS OF FIRE/SMOKE
DAMPERS AND COMPUTER ROOM AIR CONDITIONING UNITS
(CRAHU).
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ
ΔΙΑΦΡΑΓΜΑΤΑ ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ ΚΑΙ ΤΙΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΤΙΣΜΟΥ
ΤΟΥ ΔΩΜΑΤΙΟΥ Η/Υ (CRAHU)
0 100 200
SCALE 1 : 100
PLAN NORTH
2 3 4 5 6 7 8
B
C
D
N9 TECH
CONTROL
N9 EQUIPMENT
ROOM
CLASSIFIED
CONFERENCE
N00 STOR
N00C KMI
MECH
ELEC
FLEET CYBER -
SECURE
FLEET CYBER -
EQUIP
TR 2-1
STAIR 2
OH
OH
OH
OH
OH
OH
OH
OH
LH
LH
LH
LH
LH
LH
LH
A1 F-301
WOMENS
ISSM
BREAK
COMM SECURITY
MATERIAL AREA
KMI STOR
MENS
OH
OH
ELEV
LH
N3 STOR
OH
LH
OH
LH
CA A
AA
S
D C
A R
P
A
CA
AA
S
D C
A R
P
FLEET CYBER -
CONF
NOO
VESTIBULE
SSO OFFICE
WATCH CENTER
WATCH CMDR
2 JAN
PD
LH
LH
LH
STORAGE
SV
LA
LA
SV
D
PD
LA
SV
SV
LA
AA
S
D
AA
S
D
C4 F-301
C M
CM
CM
CM CM
C M
C M
C M
C M
C M
CM
D
IM
IM
SPRINKLER DESIGN CRITERIA
ΚΡΙΤΗΡΙΑ ΣΧΕΔΙΑΣΜΟΥ ΚΑΤΑΙΟΝΗΤΗΡΩΝ
HAZARD
CLASSIFICATION
ΚΑΤΗΓΟΡΙΑ
ΚΙΝΔΥΝΟΥ
DESIGN
REQUIREMENTS
ΑΠΑΙΤΗΣΕΙΣ
ΣΧΕΔΙΑΣΜΟΥ
DURATION
OF SUPPLY
ΔΙΑΡΚΕΙΑ
ΠΑΡΟΧΗΣ
SPRINKLER
SPACING MAX
ΜΕΓΙΣΤΗ
ΑΠΟΣΤΑΣΗ
ΚΑΤΑΙΟΝΗΤΗΡΩΝ
REQUIRED
SPRINKLER
ΑΠΑΙΤΟΥΜΕΝΟΙ
ΚΑΤΑΙΟΝΗΤΗΡΕΣ
LH LIGHT
ΧΑΜΗΛΟΣ
ORDINARY
ΜΕΣΑΙΟΣ
4 MM/MIN OVER MOST
REMOTE 140 M² PLUS 950
LPM HOSE STREAM
4 ΜΜ/ΜΙΝ ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ 140 M²
ΣΥΝ 950GPM ΡΟΗ ΜΑΝΙΚΑΣ
8 MM/MIN OVER MOST
REMOTE 230 M² PLUS 950
LPM HOSE STREAM
8 ΜΜ/ΜΙΝ ΣΤΟ ΠΙΟ
ΑΠΟΜΑΚΡΥΣΜΕΝΟ 230 M²
ΣΥΝ 950GPM ΡΟΗ ΜΑΝΙΚΑΣ
60 MIN
60 MIN
4.6 M
4.6 M
ORDINARY, QUICK
RESPONSE, K=80
ΣΥΝΗΘΕΙΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ, Κ=80
ORDINARY, QUICK
RESPONSE, K=115
ΣΥΝΗΘΕΙΣ, ΑΜΕΣΗΣ
ΑΠΟΚΡΙΣΗΣ, Κ=115
OH
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:1
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-103
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
FI
R
E
PR
O
TE
C
TI
O N
PL
AN
-S
EC
O N
D
FL
O O
R
14089243
Π
ΥΡ
Ο Π
ΡΟ
ΣΤ
Α
ΣΙ
Α
ΔΕ
ΥΤ
Ε
ΡΟ
Σ
Ο Ρ
Ο Φ
Ο Σ
DPS
DPS
1 : 100A1
FIRE PROTECTION SECOND FLOOR
ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΔΕΥΤΕΡΟΣ ΟΡΟΦΟΣ
1 PROVIDE VERY EARLY WARNING SMOKE DETECTION SYSTEM AND
CLEAN AGENT (FK-5-1-12) FIRE EXTINGUISHING SYSTEM ABOVE
AND BELOW THE RAISED ACCESS FLOOR.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΕΙΔΟΠΟΙΗΣΗΣ ΚΑΙ ΣΥΣΤΗΜΑ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ (FK-5-1-12) ΠΑΝΩ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟ
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ.
2 150 MM FLOOR CONTROL VALVE FOR SECOND FLOOR.
150ΜΜ ΒΑΝΑ ΕΛΕΓΧΟΥ ΟΡΟΦΟΥ ΓΙΑ ΤΟΝ 2Ο ΟΡΟΦΟ.
3 LISTED CLEAN AGENT FIRE EXTINGUISHING SYSTEM RELEASING
PANEL. MONITOR STATUS OF CLEAN AGENT RELEASING PANEL AT
THE FMCP.
ΠΙΝΑΚΑΣ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΣΥΣΤΗΜΑΤΟΣ ΚΑΘΑΡΟΥ
ΠΥΡΟΣΒΕΣΤΙΚΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΤΑΧΩΡΗΜΕΝΟΣ ΚΑΤΑ UL.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΚΑΤΑΣΤΑΣΗΣ ΤΟΥ ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ
ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΣΤΟΝ FMCP.
4 PROVIDE UPRIGHT SPRINKLERS WITH LISTED SPRINKLER GUARDS
IN ALL ELECTRONIC EQUIPMENT AREAS WITHOUT FINISHED
CEILINGS. SPRINKLERS MUST NOT BE LOCATED DIRECTLY OVER
ELECTRICAL EQUIPMENT, SERVER RACKS, OR MAJOR ELECTRICAL
COMPONENTS.
ΠΑΡΕΧΕΤΕ ΚΑΤΑΙΟΝΗΤΗΡΕΣ ΟΡΘΙΟΥ ΤΥΠΟΥ ΜΕ ΚΑΤΑΧΩΡΗΜΕΝΑ
ΠΡΟΣΤΑΤΕΥΤΙΚΑ KATA UL ΣΕ ΟΛΟΥΣ ΤΟΥΣ ΧΩΡΟΥΣ ΜΕ
ΗΛΕΚΤΡΟΝΙΚΟ ΕΞΟΠΛΙΣΜΟ, ΒΑΣΕΙΣ ΣΕΡΒΕΡ Ή ΜΕΓΑΛΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΕΞΑΡΤΗΜΑΤΑ.
5 PROVIDE AIR-ASPIRATING VERY EARLY WARNING SMOKE
DETECTION SYSTEM FOR THE ACTIVATION OF THE CLEAN AGENT
SYSTEMS PROTECTING THE SPACE ABOVE AND BELOW THE
RAISED ACCESS FLOOR WITHIN THE AREA. PROVIDE A SEPARATE
AIR ASPIRATING DETECTION PANEL FOR ABOVE THE RAISED
FLOOR AND ONE FOR BELOW THE RAISED FLOOR. CONTRACTOR
RESPONSIBLE FOR PIPE NETWORK AND SAMPLING PORT
LOCATIONS TO ENSURE PROPER FUNCTION OF SYSTEM PER
MANUFACTURER'S SPECIFICATIONS.
ΠΑΡΕΧΕΤΕ ΣΥΣΤΗΜΑ ΑΝΙΧΝΕΥΣΗΣ ΚΑΠΝΟΥ ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ
ΠΟΛΥ ΕΓΚΑΙΡΗΣ ΠΡΟΕΙΔΟΠΟΙΗΣΗΣ ΓΙΑ ΤΗΝ ΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ
ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΠΟΥ ΠΡΟΣΤΑΤΕΥΟΥΝ ΤΟΝ
ΧΩΡΟ ΠΑΝΩ ΚΑΙ ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΕΝΤΟΣ
ΤΟΥ ΧΩΡΟΥ. ΠΑΡΕΧΕΤ ΞΕΧΩΡΙΣΤΟ ΠΙΝΑΚΑ ΑΝΙΧΝΕΥΣΗΣ
ΑΝΑΡΡΟΦΗΣΗΣ ΑΕΡΑ ΓΙΑ ΠΑΝΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ
ΚΑΙ ΕΝΑΝ ΓΙΑ ΚΑΤΩ ΑΠΟ ΤΟ ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ. Ο
ΕΡΓΟΛΑΒΟΣ ΕΙΝΑΙ ΥΠΕΥΘΥΝΟΣ ΓΙΑ ΤΟ ΔΙΚΤΥΟ ΣΩΛΗΝΩΣΕΩΝ ΚΑΙ
ΤΙΣ ΘΕΣΕΣ ΤΩΝ ΣΩΛΗΝΩΝ ΔΕΙΓΜΑΤΟΛΗΨΙΑΣ ΓΙΑ ΝΑ ΔΙΑΣΦΑΛΙΣΕΙ
ΤΗΝ ΚΑΤΑΛΛΗΛΗ ΛΕΙΤΟΥΡΓΙΑ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ
ΟΔΗΓΙΕΣ ΤΟΥ ΚΑΤΑΣΚΕΥΑΣΤΗ.
6 PROVIDE SPRINKLERS WITH UL LISTED SPRINKLER GUARDS IN
ELEVATOR MACHINE ROOM ON THE PENTHOUSE LEVEL.
SPRINKLERS IN ELEVATOR MACHINE ROOM MUST HAVE
INTERMEDIATE TEMPERATURE RATING. THE SUPPLY PIPING TO
ELEVATOR MACHINE ROOM SPRINKLERS MUST BE EQUIPPED WITH
A SUPERVISED SHUT-OFF VALVE, CHECK VALVE, WATERFLOW
SWITCH, TEST VALVE, AND BE LOCATED OUTSIDE OF THE
ELEVATOR MACHINE ROOM. ROUTE TEST VALVE PIPING TO
EXTERIOR.
7 PROVIDE CONTROL MODULES FOR FIRE/SMOKE DAMPERS.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΤΑ ΔΙΑΦΡΑΓΜΑΤΑ
ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ.
8 PROVIDE CONTROL MODULES FOR CRAHU SHUTDOWN.
ΠΑΡΕΧΕΤΕ ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΓΙΑ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΤΩΝ CRAHU
9 CONTROL MODULE FOR EPO SHUTDOWN.
ΜΟΝΑΔΑ ΕΛΕΓΧΟΥ ΓΙΑ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ ΕΡΟ.
10 LOCATION OF CLEAN AGENT CYLINDER(S).
ΘΕΣΗ ΠΥΡΟΣΒΕΣΤΗΡΑ(ΩΝ) ΚΑΘΑΡΟΥ ΠΥΡΟΣΒΕΣΤΙΚΟΥ
ΠΑΡΑΓΟΝΤΑ.
11 ZONE CONTROL VALVE WITH WATER FLOW SWITCH, CHECK
VALVE, AND BUTTERFLY VALVE TAMPER SWITCH.
ΒΑΝΑ ΕΛΕΓΧΟΥ ΖΩΝΗΣ ΜΕ ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ, ΒΑΝΑ
ΕΛΕΓΧΟΥ ΚΑΙ ΒΑΝΑ ΠΕΤΑΛΟΥΔΑΣ ΜΕ ΑΝΑΓΓΕΛΙΑ ΘΕΣΗΣ ΔΙΑΚΟΠΤΗ
12 MONITOR EPO SHUTDOWN FROM ROOM CONTROL MODULES.
ΠΑΡΑΚΟΛΟΥΘΗΣΗ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗΣ EPO ΑΠΟ ΜΟΝΑΔΕΣ
ΕΛΕΓΧΟΥ ΔΩΜΑΤΙΟΥ
A. REFER TO SHEET F-001 FOR GENERAL NOTES AND SYMBOLS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΟ ΣΧΕΔΙΟ F-001 ΓΙΑ ΓΕΝΙΚΕΣ ΣΗΜΕΙΩΣΕΙΣ ΚΑΙ
ΣΥΜΒΟΛΑ
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F-501 KAI F-502 ΓΙΑ ΤΟΝ ΚΑΤΑΚΟΡΥΦΟ
ΤΩΝ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
B. REFER TO SHEETS F503 & F504 FOR CLEAN AGENT SYSTEM RISERS
AND DETAILS.
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΣΧΕΔΙΑ F503 & F504 ΓΙΑ ΚΑΤΑΚΟΡΥΦΟΥΣ
ΣΥΣΤΗΜΑΤΩΝ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ ΚΑΙ ΛΕΠΤΟΜΕΡΕΙΕΣ
C. CONTROL MODULES ASSOCIATED WITH EMEREGENCY POWER OFF
(EPO) MUST BE MONITORED BY THE CLEAN AGENT RELEASING
PANEL. REFER TO ELECTRICAL POWER PLANS FOR COORDINATION.
ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ ΜΕ ΑΠΕΝΕΡΓΟΠΟΙΗΣΗ
ΕΚΤΑΚΤΗΣ ΑΝΑΓΚΗΣ (EPO) ΠΡΕΠΕΙ ΝΑ ΕΛΕΓΧΟΝΤΑΙ ΑΠΟ ΤΟΝ
ΠΙΝΑΚΑ ΑΠΕΛΕΥΘΕΡΩΣΗΣ ΚΑΘΑΡΟΥ ΠΑΡΑΓΟΝΤΑ. ΑΝΑΦΕΡΘΕΙΤΕ
ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΣΥΝΤΟΝΙΣΜΟ.
D. REFER TO MECHANICAL PLANS FOR LOCATIONS OF FIRE/SMOKE
DAMPERS AND COMPUTER ROOM AIR CONDITIONING UNITS
(CRAHU).
ΑΝΑΦΕΡΘΕΙΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΤΙΣ ΘΕΣΕΙΣ ΤΩΝ
ΔΙΑΦΡΑΓΜΑΤΑ ΠΥΡΚΑΓΙΑΣ/ΚΑΠΝΟΥ ΚΑΙ ΤΙΣ ΜΟΝΑΔΕΣ ΚΛΙΜΑΤΙΣΜΟΥ
ΤΟΥ ΔΩΜΑΤΙΟΥ Η/Υ (CRAHU)
0 100 200
SCALE 1 : 100
PLAN NORTH
CD
LEVEL 1
10000
LEVEL 2
14570
LEVEL 3
19100
LEVEL 4
24310
COMM SECURITY
MATERIAL AREA
STAIR 2
STAIR 2
STAIR 2
FIRE PROT
LNSC DIR
LNSC ANALYSIS
PENTHOUSE LEVEL
15120
CORRIDOR
ELEVATOR
MACHINE ROOM
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
S U
PP
AC
T
SO
U D
A
BA
Y
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
N
AV
AL
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
SY
ST
EM
C
O M
M
AN
D D
E P
AR
TM
E N
T O
F
TH
E N
A
VY
N A
V
AL
FA
C
IL
IT
IE
S
E N
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
,V
A A
TL
AN
TI
C
D E
SI
G
N A
N D
C O
N
ST
R U
C
TI
O N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
1:
:2
PM
C :\U se rs
\h ar re lz s\ D oc um en ts
\P
1- D
1-
FP
_R
_z ac ha ry
.h ar re llJ
C
E.
rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
F-301
MN ZH BT
P
C
O M
M U
N
IC
A
TI
O N
C E
N
TE
RS
O
U D
A B
AY
,G
R
EE
C E
BU
IL
D
IN
G
SE
C
TI
O N
14089244
ΤΟ
Μ
Η Κ
ΤΗ
Ρ
ΙΟ
Υ
DPS
DPS
1 : 50A1
FIRE PROTECTION BUILDING
SECTION/ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΤΟΜΗ
ΚΤΗΡΙΟΥ
1 ZONE CONTROL VALVE WITH WATER FLOW SWITCH, CHECK
VALVE, AND BUTTERFLY VALVE TAMPER SWITCH.
ΒΑΝΑ ΕΛΕΓΧΟΥ ΖΩΝΗΣ ΜΕ ΔΙΑΚΟΠΤΗ ΡΟΗΣ ΝΕΡΟΥ, ΒΑΝΑ
ΕΛΕΓΧΟΥ ΚΑΙ ΒΑΝΑ ΠΕΤΑΛΟΥΔΑΣ ΜΕ ΑΝΑΓΓΕΛΙΑ ΘΕΣΗΣ ΔΙΑΚΟΠΤΗ
2 SPRINKLER MAIN SERVING GROUND FLOOR.
ΚΕΝΤΡΙΚΟΣ ΣΩΛΗΝΑΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΟΥ ΕΞΥΠΗΡΕΤΕΙ ΤΟ
ΙΣΟΓΕΙΟ
3 SPRINKLER MAIN SERVING FIRST FLOOR.
ΚΕΝΤΡΙΚΟΣ ΣΩΛΗΝΑΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΟΥ ΕΞΥΠΗΡΕΤΕΙ ΤΟΝ 1Ο
ΟΡΟΦΟ
4 SPRINKLER MAIN SERVING SECOND FLOOR.
ΚΕΝΤΡΙΚΟΣ ΣΩΛΗΝΑΣ ΚΑΤΑΙΟΝΗΤΗΡΩΝ ΠΟΥ ΕΞΥΠΗΡΕΤΕΙ ΤΟ 2Ο
ΟΡΟΦΟ
5 150 MM DOUBLE CHECK BACKFLOW PREVENTER.
150ΜΜ ΒΑΝΑ ΕΠΑΝΕΛΕΓΧΟΥ ΑΝΤΕΠΙΣΤΡΟΦΗΣ
6 THREE (3) 65 MM HOSE VALVE FOR BACKFLOW PREVENTER TEST
HEADER.
ΤΡΕΙΣ (3)65 ΜΜ ΒΑΝΕΣ ΜΑΝΙΚΑΣ ΓΙΑ ΤΗΝ ΑΝΤΕΠΙΣΤΡΟΦΗ ΚΕΦΑΛΗ
ΔΟΚΙΜΩΝ
7 PROVIDE SPRINKLERS WITH UL LISTED SPRINKLER GUARDS IN
ELEVATOR MACHINE ROOM ON THE PENTHOUSE LEVEL.
SPRINKLERS IN ELEVATOR MACHINE ROOM MUST HAVE
INTERMEDIATE TEMPERATURE RATING. THE SUPPLY PIPING TO
ELEVATOR MACHINE ROOM SPRINKLERS MUST BE EQUIPPED WITH
A SUPERVISED SHUT-OFF VALVE, CHECK VALVE, WATERFLOW
SWITCH, TEST VALVE, AND BE LOCATED OUTSIDE OF THE
ELEVATOR MACHINE ROOM. ROUTE TEST VALVE PIPING TO
EXTERIOR.
8 NORMALLY CLOSED BACKFLOW PREVENTER TEST HEADER VALVE
WITH TAMPER SWITCH. PROVIDE VALVE TAMPER SWITCH
INTENDED TO SUPERVISE VALVES IN THE NORMALLY CLOSED
POSITION.
ΚΑΝΟΝΙΚΑ ΚΛΕΙΣΤΗ ΒΑΝΑ ΑΝΤΕΠΙΣΤΡΟΦΗΣ ΚΕΦΑΛΗΣ ΔΟΚΙΜΩΝ
ΜΕ ΔΙΑΚΟΠΤΗ ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ. ΠΑΡΕΧΕΤΕ ΒΑΝΑ ΜΕ ΔΙΑΚΟΠΤΗ
ΕΝΔΕΙΞΗΣ ΘΕΣΗΣ ΓΙΑ ΤΗΝ ΕΠΙΒΛΕΨΗ ΤΩΝ ΒΑΝΩΝ ΣΤΗΝ ΚΑΝΟΝΙΚΑ
ΚΛΕΙΣΤΗ ΘΕΣΗ.
9 PROVIDE PIPE SLEEVES FOR PENETRATIONS.
ΠΑΡΕΧΕΤΕ ΜΑΝΔΥΑ ΣΩΛΗΝΑΣ ΓΙΑ ΤΙΣ ΔΙΑΤΡΗΣΕΙΣ
10 PROVIDE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .