ATT H 1615269dwg7of19.pdf
PDF 12 MB Posted
- Attached to
- P131 Communications Center - Souda Bay
- Solicitation number
- N62470-21-R-0005
About this file
This solicitation is for the construction of a communications center facility at Naval Support Activity Souda Bay, Greece. The Navy seeks a firm fixed price contract to construct a three-story concrete structure that will house a communications center, telephone exchange, electronics maintenance shops, and storage for electronics spares and equipment. Electrical utilities to be provided include primary and secondary distribution systems, transformers, telecommunications infrastructure, security systems infrastructure and lighting. The period of performance is approximately 900 days after notice to proceed. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for an unrestricted, full and open competitive procurement. The response deadline is not provided in the document.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING ABBREVIATIONS
ΣΥΝΤΟΜΕΥΣΕΙΣ ΣΧΕΔΙΟΥ
SHEET NUMBERING SYSTEM:
ΣΥΣΤΗΜΑ ΑΡΙΘΜΗΣΗΣ ΣΧΕΔΙΟΥ:
X-100
DISCIPLINE:
ΤΜΗΜΑ:
DISCIPLINE MODIFIER
ΤΡΟΠΟΠΟΙΗΤΗΣ
ΤΜΗΜΑΤΟΣ
SHEET SEQUENCE
NUMBER
ΑΡΙΘΜΟΣ ΑΚΟΛΟΥΘΙΑΣ
ΣΧΕΔΙΟΥ
LEGEND
ΥΠΟΜΝΗΜΑ
A. VERIFY FIELD CONDITIONS PRIOR TO
COMMENCEMENT OF EACH PORTION OF THE WORK.
ΕΠΑΛΗΘΕΥΣΤΕ ΣΥΝΘΗΚΕΣ ΠΕΔΙΟΥ ΠΡΙΝ ΤΗΝ ΕΝΑΡΞΗ
ΚΑΘΕ ΤΜΗΜΑΤΟΣ ΤΗΣ ΕΡΓΑΣΙΑΣ
B. PLAN DIMENSIONS ARE TO THE FACE OF METAL STUD
OR CONCRETE, UNLESS NOTED OTHERWISE.
ΟΙ ΔΙΑΣΤΑΣΕΙΣ ΣΤΙΣ ΚΑΤΟΨΕΙΣ ΕΙΝΑΙ ΣΤΗΝ ΑΚΡΗ ΤΟΥ
ΜΕΤΑΛΛΙΚΟΥ ΟΡΘΟΣΤΑΤΗ Ή ΤΟΥ ΣΚΥΡΟΔΕΜΑΤΟΣ,
ΕΚΤΟΣ ΚΑΙ ΑΝ ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ.
C. FOR DEPRESSED FLOORS AND CURBS, REFER
STRUCTURAL DRAWINGS.
ΓΙΑ ΔΑΠΕΔΑ ΣΕ ΕΣΟΧΗ ΚΑΙ ΚΡΑΣΠΕΔΑ, ΒΛΕΠΕ
ΣΤΑΤΙΚΑ ΣΧΕΔΙΑ.
D. VERIFY ROUGH-IN DIMENSIONS FOR EQUIPMENT
PROVIDED IN THIS CONTRACT OR BY OTHERS.
ΕΠΑΛΗΘΕΥΣΤΕ ΤΙΣ ΑΡΧΙΚΕΣ ΔΙΑΣΤΑΣΕΙΣ ΓΙΑ ΤΟΝ
ΕΞΟΠΛΙΣΜΟ ΠΟΥ ΠΑΡΕΧΕΤΑΙ ΣΕ ΑΥΤΗΝ ΤΗΝ ΣΥΜΒΑΣΗ
Η' ΑΠΟ ΑΛΛΟΥΣ.
E. WHERE COLOR IS SHOWN AS BEING SPECIFIC TO
ONE MANUFACTURER, AN EQUIVALENT COLOR BY
ANOTHER MANUFACTURER MAY BE SUBMITTED FOR
APPROVAL. MANUFACTURERS AND MATERIALS
SPECIFIED ARE NOT INTENDED TO LIMIT THE
SELECTION OF EQUAL COLORS FROM OTHER
MANUFACTURERS.
ΟΠΟΥ ΔΕΙΧΝΕΤΑΙ ΧΡΩΜΑ ΤΟ ΟΠΟΙΟ ΕΙΝΑΙ
ΣΥΓΚΕΚΡΙΜΕΝΟ ΣΕ ΕΝΑ ΚΑΤΑΣΚΕΥΑΣΤΗ, ΕΝΑ
ΙΣΟΔΥΝΑΜΟ ΧΡΩΜΑ ΑΠΟ ΑΛΛΟ ΚΑΤΑΣΚΕΥΑΣΤΗ
ΜΠΟΡΕΙ ΝΑ ΥΠΟΒΛΗΘΕΙ ΓΙΑ ΕΓΚΡΙΣΗ.
ΟΙ ΚΑΤΑΣΚΕΥΑΣΤΕΣ ΚΑΙ ΤΑ ΥΛΙΚΑ ΠΟΥ
ΠΡΟΣΔΙΟΡΙΖΟΝΤΑΙ ΔΕΝ ΕΧΟΥΝ ΣΚΟΠΟ ΝΑ
ΠΕΡΙΟΡΙΣΟΥΝ ΤΗΝ ΕΠΙΛΟΓΗ ΤΩΝ ΙΣΟΔΥΝΑΜΩΝ
ΧΡΩΜΑΤΩΝ ΑΠΟ ΑΛΛΟΥΣ ΚΑΤΑΣΚΕΥΑΣΤΕΣ
F. FLOOR MATERIAL TRANSITIONS TO OCCUR AT
CENTERLINE OF DOOR UNLESS NOTED OTHERWISE.
Η ΜΕΤΑΒΑΣΗ ΥΛΙΚΩΝ ΔΑΠΕΔΟΥ ΝΑ ΓΙΝΕΤΑΙ ΣΤΗ
ΚΕΝΤΡΙΚΗ ΓΡΑΜΜΗ ΤΗΣ ΠΟΡΤΑΣ ΕΚΤΟΣ ΚΑΙ ΑΝ
ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ.
G. PENETRATIONS AND OPENINGS MUST MEET
PARTITION ASSEMBLY FIRE RATINGS AND
ACOUSTICAL RATINGS PER ARCHITECTURAL
FLOOR PLANS.
ΟΙ ΔΙΑΝΟΙΞΕΙΣ ΚΑΙ ΤΑ ΑΝΟΙΓΜΑΤΑ ΠΡΕΠΕΙ ΝΑ
ΤΗΡΟΥΝ ΤΟΝ ΒΑΘΜΟ ΠΥΡΑΝΤΟΧΗΣ ΚΑΙ ΤΟΝ ΒΑΘΜΟ
ΗΧΟΜΟΝΩΣΗΣ ΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΧΩΡΙΣΜΑΤΩΝ
ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΑΡΧΙΤΕΚΤΟΝΙΚΕΣ ΚΑΤΟΨΕΙΣ.
H. PROVIDE METAL STRAPPING WITHIN PARTITIONS AT
CASEWORK, WALL-MOUNTED EQUIPMENT, AND
TOILET ACCESSORIES.
ΠΡΟΜΗΘΕΥΣΤΕ ΜΕΤΑΛΛΙΚΑ ΣΤΗΡΙΓΜΑΤΑ ΜΕΣΑ
ΣΤΑ ΧΩΡΙΣΜΑΤΑ ΤΗΣ ΕΠΙΠΛΩΣΗΣ,ΣΤΟΝ ΕΠΙΤΟΙΧΙΟ
ΕΞΟΠΛΙΣΜΟ ΚΑΙ ΣΤΑ ΕΞΑΡΤΗΜΑΤΑ ΤΟΥΑΛΕΤΑΣ.
J. REFER TO COLOR AND MATERIALS SCHEDULE
FOR MANUFACTURER, COLOR, AND MATERIAL
INFORMATION.
ΑΝΑΤΡΕΞΤΕ ΣΕ ΠΙΝΑΚΑ ΧΡΩΜΑΤΩΝ ΚΑΙ ΥΛΙΚΩΝ
ΓΙΑ ΚΑΤΑΣΚΕΥΑΣΤΗ,ΠΛΗΡΟΦΟΡΙΕΣ ΥΛΙΚΩΝ ΚΑΙ
ΧΡΩΜΑΤΩΝ.
K. REFER TO ROOM FINISH SCHEDULE FOR FLOOR,
BASE, PARTITION, AND CEILING FINISH
DESIGNATIONS.
ΑΝΑΤΡΕΞΤΕ ΣΕ ΠΙΝΑΚΑ ΤΕΛΕΙΩΜΑΤΩΝ ΔΩΜΑΤΙΩΝ
ΓΙΑ ΟΝΟΜΑΣΙΕΣ ΤΕΛΕΙΩΜΑΤΩΝ ΔΑΠΕΔΩΝ,
ΣΟΒΑΤΕΠΙ ΔΑΠΕΔΩΝ, ΧΩΡΙΣΜΑΤΩΝ ΚΑΙ
ΨΕΥΔΟΡΟΦΩΝ.
L. REFER TO ARCHITECTURAL FLOOR PLANS AND
DRAWING A-601 FOR PARTITION TYPE DETAILS.
ΑΝΑΤΡΕΞΤΕ ΣΕ ΑΡΧΙΤΕΚΤΟΝΙΚΕΣ ΚΑΤΟΨΕΙΣ ΚΑΙ
ΣΤΟ ΣΧΕΔΙΟ Α-601 ΓΙΑ ΛΕΠΤΟΜΕΡΕΙΕΣ ΤΥΠΩΝ
ΧΩΡΙΣΜΑΤΩΝ.
M. REFER TO INTERIOR SHEETS FOR STANDARD
MOUNTING HEIGHTS
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΕΣΩΤΕΡΙΚΩΝ ΧΩΡΩΝ ΓΙΑ
ΤΥΠΙΚΑ ΥΨΗ ΤΟΠΟΘΕΤΗΣΗΣ.
N. REFER TO ARCHITECTURAL REFLECTED CEILING
PLANS AND ROOM FINISH SCHEDULE FOR CEILING
HEIGHTS.
ΑΝΑΤΡΕΞΤΕ ΣΕ ΑΡΧΙΤΕΚΤΟΝΙΚΕΣ ΑΝΟΨΕΙΣ
ΨΕΥΔΟΡΟΦΗΣ ΚΑΙ ΣΕ ΠΙΝΑΚΑ ΤΕΛΕΙΩΜΑΤΩΝ
ΔΩΜΑΤΙΩΝ ΓΙΑ ΥΨΗ ΨΕΥΔΟΡΟΦΗΣ.
P. REFER TO ARCHITECTURAL ENLARGED PLANS
FOR TOILET ACCESSORY LOCATIONS.
ΑΝΑΤΡΕΞΤΕ ΣΕ ΑΡΧΙΤΕΚΤΟΝΙΚΕΣ ΚΑΤΟΨΕΙΣ
ΜΕΓΕΝΘΥΝΣΗΣ ΓΙΑ ΘΕΣΕΙΣ ΕΞΑΡΤΗΜΑΤΩΝ
ΤΟΥΑΛΕΤΑΣ
R. REFER TO MECHANICAL / PLUMBING FOR RADON
MITIGATION INFORMATION.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ / ΥΔΡΑΥΛΙΚΑ ΓΙΑ
ΠΛΗΡΟΦΟΡΙΕΣ ΣΧΕΤΙΚΑ ΜΕ ΤΗΝ ΜΕΙΩΣΗ ΤΟΥ
ΡΑΔΟΝΙΟΥ.
MATERIALS LEGEND
ΥΠΟΜΝΗΜΑ ΥΛΙΚΩΝ
A --------------------- Α
A/C AIR CONDITION
ΚΛΙΜΑΤΙΣΜΟΣ
A/E ARCHITECT/ENGINEER
ΑΡΧΤΕΚΤΟΝΑΣ/ΜΗΧΑΝΙΚΟΣ
ACC ACCESSIBLE
ΠΡΟΣΒΑΣΙΜΟ
ACT ACOUSTICAL CEILING TILE
ΠΛΑΚΙΔΙΑ ΟΡΥΚΤΩΝ ΙΝΩΝ
ADA AMERICANS WITH DISABILITIES
ACT
ΝΟΜΟΣΧΕΔΙΟ ΓΙΑ
ΑΜΕΡΙΚΑΝΟΥΣ ΜΕ ΑΝΑΠΗΡΙΕΣ
ADMIN ADMINISTRATION
ΔΙΟΙΚΗΣΗ
AFF ABOVE FINISHED FLOOR
ΑΝΩΘΕΝ ΤΕΛΕΙΩΜΕΝΟΥ
ΔΑΠΕΔΟΥ
AHU AIR HANDLING UNIT
ΜΟΝΑΔΑ ΔΙΑΧΕΙΡΙΣΗΣ ΑΕΡΑ
AIB AIR INFILTRATION BARRIER
ΦΡΑΓΜΑ ΔΙΕΙΣΔΥΣΗΣ ΑΕΡΑ
ALT ALTERNATE
ΕΝΑΛΛΑΚΤΙΚΑ
AL, ALUM ALUMINUM
ΑΛΟΥΜΙΝΙΟΥ
ANOD ANODIZE
ΑΝΟΔΙΚΑ
APPROX APPROXIMATE
ΠΕΡΙΠΟΥ
ARCH ARCHITECT
ΑΡΧΙΤΕΚΤΟΝΙΚΑ
ATC ACOUSTICAL TILE CEILING
ΨΕΥΔΟΡΟΦΗ ΟΡΥΚΤΩΝ ΙΝΩΝ
AVG AVERAGE
ΚΑΤΑ ΜΕΣΟ ΟΡΟ
B --------------------- Β
BD BOARD
ΣΑΝΙΔΑ
BLDG BUILDING
ΚΤΙΡΙΟ
BLKG BLOCKING
ΞΥΛΙΝΟΣ ΤΑΚΟΣ
BOS BOTTOM OF STEEL
ΚΑΤΩ ΜΕΡΟΣ ΑΤΣΑΛΙΟΥ
BOT BOTTOM
ΚΑΤΩ ΜΕΡΟΣ
BRKT BRACKET
ΣΥΝΔΕΣΗ
BTWN BETWEEN
ΜΕΤΑΞΥ
C --------------------- C
CD CONSTRUCTION DOCUMENTS
ΕΓΓΡΑΦΑ ΚΑΤΑΣΚΕΥΗΣ
CF CONTRACTOR FURNISHED
ΠΡΟΜΗΘΕΙΑ ΑΠΟ ΕΡΓΟΛΑΒΟ
CF/CI CONTRACTOR FURNISHED
/CONTRACTOR INSTALLED
ΠΡΟΜΗΘΕΙΑ ΚΑΙ ΤΟΠΟΘΕΤΗΣΗ
ΑΠΟ ΤΟΝ ΕΡΓΟΛΑΒΟ
CFE CONTRACTOR FURNISHED
EQUIPMENT
ΠΡΟΜΗΘΕΙΑ ΕΞΟΠΛΙΣΜΟΥ ΑΠΟ
ΕΡΓΟΛΑΒΟ
CFM CUBIC FEET PER MINUTE
ΚΥΒΙΚΟ ΠΟΔΙ ΑΝΑ ΛΕΠΤΟ
CFS CUBIC FEET PER SECOND
ΚΥΒΙΚΟ ΠΟΔΙ ΑΝΑ
ΔΕΥΤΕΡΟΛΕΠΤΟ
CG CORNER GUARD
ΠΡΟΣΤΑΣΙΑ ΓΩΝΙΑΣ
CIP CAST-IN-PLACE
ΕΠΙ ΤΟΠΟΥ
CJ CONTROL JOINT
ΑΝΤΙΣΕΙΣΜΙΚΟΣ ΑΡΜΟΣ
CL CENTER LINE
ΓΡΑΜΜΗ ΚΕΝΤΡΟΥ
CLG CEILING
ΨΕΥΔΟΡΟΦΗ
CLR CLEAR
ΚΑΘΑΡΟ
CR CARD READER
ΜΗΧΑΝΗΜΑ ΑΝΑΓΝΩΣΗΣ ΚΑΡΤΑΣ
CO CLEANOUT
ΤΑΠΑ ΚΑΘΑΡΙΣΜΟΥ
COL COLUMN
ΚΟΛΩΝΑ
COMM COMMUNICATION
ΕΠΙΚΟΙΝΩΝΙΑ
CONC CONCRETE
ΣΚΥΡΟΔΕΜΑ
CONF CONFERENCE
ΣΥΣΚΕΨΗ
CONT CONTINUE
ΣΥΝΕΧΕΙΑ
COORD COORDINATE
ΣΥΝΤΟΝΙΖΩ
CORR CORRIDOR
ΔΙΑΔΡΟΜΟΣ
CPT CARPET
ΜΟΚΕΤΑ
CT CERAMIC TILE
ΚΕΡΑΜΙΚΟ ΠΛΑΚΙΔΙΟ
INSUL INSULATION
ΜΕ ΜΟΝΩΣΗ
INT INTERIOR
ΕΣΩΤΕΡΙΚΟ
J --------------------- J
JAN JANITOR
ΕΠΙΣΤΑΤΗΣ
K --------------------- Κ L --------------------- L
LAM LAMINATE
ΠΟΛΥΣΤΡΩΜΑΤΙΚΟ
LAV LAVATORY
ΝΙΠΤΗΡΑΣ
LBS POUND
ΛΙΒΡΑ
LT LIGHT
ΦΩΤΙΣΤΙΚΟ
LVR LOUVER
ΠΕΡΣΙΔΑ
M --------------------- Μ
MATL MATERIAL
ΥΛΙΚΟ
MAX MAXIMUM
ΜΕΓΙΣΤΟ
MECH MECHANICAL
ΜΗΧΑΝΟΛΟΓΙΚΟ
MFR MANUFACTURER
ΚΑΤΑΣΚΕΥΑΣΤΗΣ
MIL STD MILITARY STANDARD
ΠΡΟΤΥΠΟ ΣΤΡΑΤΟΥ
MIN MINIMUM, MINUTE
ΕΛΑΧΙΣΤΟ,ΛΕΠΤΟ
MISC MISCELLANEOUS
ΔΙΑΦΟΡΑ
MOD MODIFY
ΤΡΟΠΟΠΟΙΩ
MTL METAL
ΜΕΤΑΛΛΙΚΟ
N --------------------- Ν
N NORTH
ΒΟΡΕΙΟ
NA NOT APPLICABLE
MH ΕΦΑΡΜΟΣΙΜΟ
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
ΔΙΕΘΝΗΣ ΟΡΓΑΝΙΣΜΟΣ
ΠΡΟΣΤΑΣΙΑΣ ΑΠΟ ΠΥΡΚΑΓΙΑ
NIC NOT IN CONTRACT
ΔΕ ΣΥΜΠΕΡΙΛΑΜΒΑΝΕΤΑΙ ΣΤΟ
ΣΥΜΒΟΛΑΙΟ
NO NUMBER
ΑΡΙΘΜΟΣ
NOM NOMINAL
ΟΝΟΜΑΣΤΙΚΟΣ
NR NO RATING
ΧΩΡΙΣ ΒΑΘΜΟΛΟΓΙΑ
NRC NOISE REDUCTION
COEFFICIENT
ΣΥΝΤΕΛΕΣΤΗΣ ΜΕΙΩΣΗΣ ΘΟΡΥΒΟΥ
NTS NOT TO SCALE
ΧΩΡΙΣ ΚΛΙΜΑΚΑ
O ------------------- Ο
OC ON CENTER
ΣΤΟ ΚΕΝΤΡΟ
OFD OVERFLOW DRAIN
ΑΠΟΡΡΟΗ ΥΠΕΡΧΕΙΛΙΣΗΣ
OPNG OPENING
ΑΝΟΙΓΜΑ
OPP OPPOSITE
ΑΝΤΙΘΕΤΑ
ORD OVERFLOW ROOF DRAIN
ΑΠΟΡΡΟΗ ΥΠΕΡΧΕΙΛΙΣΗΣ
ΣΤΕΓΗΣ
P -------------------- P
P PAINT
ΒΑΜΜΕΝΟ
PCF POUNDS PER CUBIC FOOT
ΛΙΒΡΕΣ ΑΝΑ ΚΥΒΙΚΑ ΠΟΔΙΑ
PH PHASE
ΦΑΣΗ
PLAM PLASTIC LAMINATE
ΠΛΑΣΤΙΚΟ
ΠΟΛΥΣΤΡΩΜΑΤΙΚΟ
PLYWD PLYWOOD
ΚΟΝΤΡΑ ΠΛΑΚΕ
PSF POUNDS PER SQUARE FOOT
ΛΙΒΡΕΣ ΑΝΑ ΤΕΤΡΑΓΩΝΙΚΑ
ΠΟΔΙΑ
PSI POUNDS PER SQUARE INCH
ΛΙΒΡΕΣ ΑΝΑ ΤΕΤΡΑΓΩΝΙΚΗ
ΙΝΤΣΑ
Q -------------------- Q
QTY QUANTITY
ΠΟΣΟΤΗΤΑ
R -------------------- R
RB RESILIENT BASE
ΑΝΘΕΚΤΙΚΟ ΣΟΒΑΤΕΠΙ
RCP REFLECTED CEILING PLAN
ΑΝΟΨΗ ΨΕΥΔΟΡΟΦΗΣ
RD ROOF DRAIN
ΥΔΡΟΡΡΟΗ ΣΤΕΓΗΣ
REF REFERENCE
ΑΝΑΦΟΡΑ
REQD REQUIRED
ΑΠΑΙΤΕΙΤΑΙ
RM ROOM
ΔΩΜΑΤΙΟ
RO ROUGH OPENING
ΑΝΟΙΓΜΑ ΧΤΙΣΤΟΥ
S -------------------- S
SCHED SCHEDULE
ΠΙΝΑΚΑΣ
SIM SIMILAR
ΠΑΡΟΜΟΙΟ
SM SQUARE METERS
ΤΕΤΡΑΓΩΝΙΚΑ ΜΕΤΡΑ
SPEC SPECIFICATION
ΠΡΟΔΙΑΓΡΑΦΗ
SQ SQUARE
ΤΕΤΡΑΓΩΝΟ
SRC SEMI-RECESSED FIRE
EXTINGUISHER CABINET
ΗΜΙ-ΧΩΝΕΥΤΟ ΕΡΜΑΡΙΟ
ΠΥΡΟΣΒΕΣΤΗΡΑ
SS STAINLESS STEEL
ΑΝΟΞΕΙΔΩΤΟ ΑΤΣΑΛΙ
STD STANDARD
ΣΤΑΘΕΡΟΣ
STOR STORAGE
ΑΠΟΘΗΚΗ
STL STEEL
ΑΤΣΑΛΙ
STRUCT STRUCTURE,
STRUCTURAL
ΚΑΤΑΣΚΕΥΗ,
ΔΟΜΙΚΟΣ
T -------------------- Τ
TEMP TEMPORARY
ΠΡΟΣΩΡΙΝΟ
T.O. TOP OF
ΣΤΕΨΗ
TOPO TOPOGRAPHY
ΤΟΠΟΓΡΑΦΙΑ
TOS TOP OF SLAB
ΣΤΕΨΗ ΤΗΣ ΠΛΑΚΑΣ
TV TELEVISION
ΤΗΛΕΟΡΑΣΗ
TYP TYPICAL
ΤΥΠΙΚΟ
U -------------------- U
UNO UNLESS NOTED OTHERWISE
ΕΚΤΟΣ ΚΑΙ ΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
V -------------------- V W -------------------- W
W/ WITH
ΜΕ
WD WOOD
ΞΥΛΟ
X -------------------- X Y -------------------- Y Z -------------------- Z
CTR CENTER
ΚΕΝΤΡΟ
CU FT CUBIC FEET
ΚΥΒΙΚΟ ΠΟΔΙ
D --------------------- D
DBL DOUBLE
ΔΙΠΛΟ
DEMO DEMOLITION
ΚΑΤΕΔΑΦΙΣΗ
DEPT DEPARTMENT
ΤΜΗΜΑ
DIA DIAMETER
ΔΙΑΜΕΤΡΟΣ
DIST DISTANCE
ΑΠΟΣΤΑΣΗ
DOC DOCUMENT
ΕΓΓΡΑΦΟ
DR DOOR
ΠΟΡΤΑ
DS DOWNSPOUT
ΥΔΡΟΟΡΡΟΗ
E --------------------- Ε
EA EACH
ΚΑΘΕ
EJ EXPANSION JOINT
ΑΡΜΟΣ ΔΙΑΣΤΟΛΗΣ
EL ELEVATION
ΣΤΑΘΜΗ
ELEV ELEVATOR
ΑΝΕΛΚΥΣΤΗΡΑΣ
EQ EQUAL
ΙΣΟΔΥΝΑΜΟ
EWC ELECTRIC WATER COOLER
ΗΛΕΚΤΡΙΚΟΣ ΨΥΚΤΗΣ ΝΕΡΟΥ
EXT EXTERIOR, EXTINGUISHER
ΕΞΩΤΕΡΙΚΟΣ,ΠΥΡΟΣΒΕΣΤΗΡΑΣ
F --------------------- F
FCO FLOOR CLEANOUT
ΤΑΠΑ ΚΑΘΑΡΙΣΜΟΥ
ΔΑΠΕΔΟΥ
FD FLOOR DRAIN
ΣΙΦΩΝΙ ΔΑΠΕΔΟΥ
FE FIRE EXTINGUISHER
ΠΥΡΟΣΒΕΣΤΗΡΑΣ
FEC FIRE EXTINGUISHER CABINET
ΕΡΜΑΡΙΟ ΠΥΡΟΣΒΕΣΤΉΡΑ
FED FEDERAL
ΟΜΟΣΠΟΝΔΙΑΚΟΣ
FF FINISH FACE
ΠΛΕΥΡΑ ΤΕΛΕΙΩΜΑΤΟΣ
FIN FINISH
ΤΕΛΕΙΩΜΑ
FIN FLR FINISH FLOOR
ΤΕΛΕΙΩΜΕΝΟ ΔΑΠΕΔΟ
FIXT FIXTURE
ΕΞΑΡΤΗΜΑ
FLR FLOOR
ΔΑΠΕΔΟ
FRP FIBERGLASS REINFORCED
PLASTIC
ΠΛΑΣΤΙΚΟ ΕΝΙΣΧΥΜΕΝΟ ΜΕ
ΥΑΛΟΒΑΜΒΑΚΑ
FS FEDERAL SPECIFICATION
ΠΡΟΔΙΑΓΡΑΦΗ ΟΜΟΣΠΟΝΔΙΑΣ
G --------------------- G
G NATURAL GAS
ΦΥΣΙΚΟ ΑΕΡΙΟ
GALV GALVANIZED
ΓΑΛΒΑΝΙΣΜΕΝΟ
GB GRAB BAR
ΜΠΑΡΑ ΣΤΗΡΙΞΗΣ
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
ΠΡΟΜΗΘΕΙΑ ΑΠΟ ΚΥΒΕΡΝΗΣΗ
ΤΟΠΟΘΕΤΗΣΗ ΑΠΟ ΕΡΓΟΛΑΒΟ
GFGI GOVERNMENT INSTALLED
FURNISHED INSTALLED BY
GOVERNMENT
ΠΡΟΜΗΘΕΙΑ KAI ΤΟΠΟΘΕΤΗΣΗ ΑΠΟ
ΚΥΒΕΡΝΗΣΗ
GLZ GLAZING
TZAMI
GYP BD GYPSUM BOARD
ΓΥΨΟΣΑΝΙΔΑ
H --------------------- H
HDW HARDWARE
ΕΞΑΡΤΗΜΑΤΑ
HM HOLLOW METAL
ΚΟΙΛΟΔΟΚΟΣ
HORIZ HORIZONTAL
ΟΡΙΖΟΝΤΙΟ
HT HEIGHT
ΥΨΟΣ
I --------------------- Ι
IBC INTERNATIONAL BUILDING
CODE
ΔΙΕΘΝΗΣ ΚΤΙΡΙΑΚΟΣ
ΚΑΝΟΝΙΣΜΟΣ
ANNOTATION LEGEND / SYMBOLS
ΥΠΟΜΝΗΜΑ ΣΧΟΛΙΩΝ / ΣΥΜΒΟΛΩΝ
REVISION TAG
ΕΤΙΚΕΤΑ
ΕΠΑΛΗΘΕΥΣΗΣ
NORTH ARROW
w/ TRUE NORTH
INDICATION
ΣΗΜΕΙΟ ΒΟΡΡΑ
ΜΕ ΕΝΔΕΙΞΗ
ΠΡΑΓΜΑΤΙΚΟΥ
ΒΟΡΡΑ
ROOM TAG
ΕΤΙΚΕΤΑ
ΔΩΜΑΤΙΟΥ
ELEVATION NUMBER
ΑΡΙΘΜΟΣ ΟΨΗΣ
SECTION
ΤΟΜΗ
ENLARGEMENT,
DETAIL
ΜΕΓΕΘΥΝΣΗ,
ΛΕΠΤΟΜΕΡΕΙΑ
LEVEL NAME
ΟΝΟΜΑ
ΣΤΑΘΜΗΣ
SHEET NUMBER
ΑΡΙΘΜΟΣ
ΣΧΕΔΙΟΥ
SHEET NUMBER
ΑΡΙΘΜΟΣ
ΣΧΕΔΙΟΥ
A SHEET KEYNOTE
ΠΑΡΑΤΗΡΗΣΗ
ΣΧΕΔΙΟΥ
INTERIOR ELEVATION
ΕΣΩΤΕΡΙΚΗ ΟΨΗ
SHEET NUMBER
ΑΡΙΘΜΟΣ ΣΧΕΔΙΟΥ
Name Elevation
Room name
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
A101
SIM
A101
A101
GENERAL NOTES
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ
CONCRETE
ΣΚΥΡΟΔΕΜΑ
SOIL
ΕΔΑΦΟΣ
CAST-IN-PLACE FORM LINER
ΑΝΑΓΛΥΦΟ ΚΑΛΟΥΠΙ ΓΙΑ ΕΠΙΤΟΠΟΥ
ΣΚΥΡΟΔΕΤΗΣΗ
RIGID INSULATION
ΑΚΑΜΠΤΗ ΜΟΝΩΣΗ
BATT INSULATION
ΜΟΝΩΣΗ ΣΕ ΡΟΛΟ
TYPICAL DOOR PLACEMENT
PULL SIDE (UNO)
ΤΥΠΙΚΗ ΤΟΠΟΘΕΤΗΣΗ ΠΟΡΤΑΣ
ΑΠΟ ΤΗΝ ΠΛΕΥΡΑ ΕΛΞΗΣ (UNO)
TYPICAL DOOR
PLACEMENT (UNO)
ΤΥΠΙΚΗ ΤΟΠΟΘΕΤΗΣΗ
ΠΟΡΤΑΣ (UNO)
TYPICAL DOOR PLACEMENT
PUSH SIDE (UNO)
ΤΥΠΙΚΗ ΤΟΠΟΘΕΤΗΣΗ
ΠΟΡΤΑΣ ΑΠΟ ΤΗΝ ΠΛΕΥΡΑ
ΩΘΗΣΗΣ (UNO)
TYPICAL DOOR
PLACEMENT (UNO)
ΤΥΠΙΚΗ ΤΟΠΟΘΕΤΗΣΗ
ΠΟΡΤΑΣ (UNO)
MIN
TYP
MIN
EQ EQ
STANDARD DOOR LOCATIONS
ΠΡΟΤΥΠΕΣ ΘΕΣΕΙΣ ΠΟΡΤΑΣ
A 4 1 A
WALL PARTITION TAG,
REFER SHEET A-601
ΕΤΙΚΕΤΑ ΧΩΡΙΣΜΑΤΟΣ
ΤΟΙΧΟΥ, ΑΝΑΦΕΡΕΤΕ
ΣΤΟ ΣΧΕΔΙΟ Α-601
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
NONE
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:5
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-001
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
G
EN
ER
AL
N O
TE
S
/ A
BB
R
EV
IA
TI
O N
S
14089153
ΓΕ
Ν
ΙΚ
ΕΣ
Π
ΑΡ
ΑΤ
Η
ΡΗ
ΣΕ
ΙΣ
/Σ
ΥΝ
ΤΟ
Μ Ο
ΓΡ
ΑΦ
ΙΕ
Σ
DER
DPS
CRACU-1
C1 C2
HP-1
HPOU-2
HP-2
HP-3
PRAC-B
PRAC-A
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:0
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
AD101
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
D
EM
O
LI
TI
O
N P
LA
N
BU
IL
D
IN
G
14089154
ΣΧ
ΕΔ
ΙΟ
ΚΑ
ΤΕ
Δ
ΑΦ
ΙΣ
Ε Ω Ν
-Κ
ΤΙ
ΡΙ
Ο
DER
DPS
SCALE: 1 : 100A1
DEMOLITION PLAN - BLDG 4
ΣΧΕΔΙΟ ΚΑΤΕΔΑΦΙΣΕΩΝ - ΚΤΙΡΙΟ 4
A FIELD VERIFY CONDITIONS PRIOR TO START OF WORK.
ΝΑ ΓΙΝΕΙ ΕΠΙΤΟΠΟΥ ΕΠΙΒΕΒΑΙΩΣΗ ΤΩΝ ΣΥΝΘΗΚΩΝ ΠΡΙΝ ΤΗΝ
ΕΝΑΡΞΗ ΤΩΝ ΕΡΓΑΣΙΩΝ
B EQUIPMENT THAT CAN BE SALVAGED DURING
DEMOLITION MUST BE UNIQUELY IDENTIFIED AND MUST BE
TURNED OVER AND TRANSPORTED TO ON SITE STORAGE
IDENTIFIED BY OWNER. EQUIPMENT TURNED DOWN BY
OWNER MUST BE DISPOSED OF PROPERLY.
ΕΞΟΠΛΙΣΜΟΣ ΠΟΥ ΔΕΝ ΜΠΟΡΕΙ ΝΑ ΔΙΑΣΩΘΕΙ ΚΑΤΑ ΤΗ
ΔΙΑΡΚΕΙΑ ΤΗΣ ΚΑΤΕΔΑΦΙΣΗΣ ΠΡΕΠΕΙ ΝΑ ΑΝΑΓΝΩΡΙΖΕΤΑΙ ΚΑΙ
ΝΑ ΕΠΙΣΤΡΕΦΕΤΑΙ ΓΙΑ ΜΕΤΑΦΟΡΑ ΣΕ ΧΩΡΟ ΑΠΟΘΗΚΕΥΣΗΣ
ΣΤΟ ΠΕΔΙΟ ΕΓΚΕΚΡΙΜΕΝΟ ΑΠΟ ΤΟΝ ΙΔΙΟΚΤΗΤΗ. Ο
ΕΞΟΠΛΙΣΜΟΣ ΠΡΟΣ ΑΠΟΡΡΙΨΗ ΑΠΟ ΤΟΝ ΙΔΙΟΚΤΗΤΗ ΠΡΕΠΕΙ
ΝΑ ΑΠΟΡΡΙΠΤΕΤΑΙ ΟΡΘΑ.
C MAINTAIN SUPERVISION OF SITE WHENEVER WORK IS BEING
PERFORMED.
ΝΑ ΠΑΡΕΧΕΤΑΙ ΣΥΝΕΧΗΣ ΕΠΙΒΛΕΨΗ ΣΤΟ ΠΕΔΙΟ ΚΑΘΟΛΗ ΤΗ
ΔΙΑΡΚΕΙΑ ΠΟΥ ΕΚΤΕΛΟΥΝΤΑΙ ΕΡΓΑΣΙΕΣ
D KEEP PREMISES FREE FROM ACCUMULATION OF WASTE
MATERIALS DAILY.
ΝΑ ΔΙΑΤΗΡΕΙΤΑΙ Ο ΧΩΡΟΣ ΕΛΕΥΘΕΡΟΣ ΑΠΟ ΣΥΣΣΩΡΕΥΣΗ
ΑΠΟΒΛΗΤΩΝ ΚΑΘΗΜΕΡΗΝΑ
E PROTECT ADJACENT SIDEWALKS, ROADWAYS, AND ADJACENT
STRUCTURES FROM DAMAGE DURING DEMOLITION WORK;
PATCH DAMAGED AREAS TO ORIGINAL CONDITION WITH
MATERIAL. REFER SHEET CD101, 102, & 103
ΝΑ ΠΡΟΣΤΑΤΕΥΤΟΥΝ ΤΑ ΠΑΡΑΚΕΙΜΕΝΑ ΠΕΖΟΔΡΟΜΙΑ, ΟΔΟΙ
ΚΑΙ ΠΑΡΑΚΕΙΜΕΝΕΣ ΚΑΤΑΣΚΕΥΕΣ ΑΠΟ ΚΑΤΑΣΤΡΟΦΗ ΚΑΤΑ ΤΗ
ΔΙΑΡΚΕΙΑ ΤΩΝ ΕΡΓΑΣΙΩΝ ΚΑΤΕΔΑΦΙΣΗΣ, ΝΑ ΣΥΜΠΛΗΡΩΘΟΥΝ
ΠΕΡΙΟΧΕΣ ΜΕ ΤΥΧΩΝ ΖΗΜΙΕΣ ΩΣΤΕ ΝΑ ΕΠΑΝΕΛΘΟΥΝ ΣΤΗΝ
ΑΡΧΙΚΗ ΚΑΤΑΣΤΑΣΗ ΜΕ ΥΛΙΚΟ ΠΛΗΡΩΣΗΣ. ΒΛΕΠΕ ΣΧΕΔΙΑ
CD101, 102 & 103.
F MAINTAIN EXISTING UTILITIES TO REMAIN IN SERVICE AND
PROTECT FROM DAMAGE. SEE SHEET CD101 FOR ADDITIONAL
DETAIL ON REMOVAL OF SITE UTILITIES.
ΝΑ ΔΙΤΗΡΗΘΟΥΝ ΤΑ ΥΦΙΣΤΑΜΕΝΑ ΔΙΚΤΥΑ ΟΦΕΛΕΙΩΝ ΩΣΤΕ ΝΑ
ΠΑΡΑΜΕΙΝΟΥΝ ΣΕ ΛΕΙΤΟΥΡΓΙΑ ΚΑΙ ΝΑ ΠΡΟΣΤΑΤΕΥΤΟΥΝ ΑΠΟ
ΖΗΜΙΕΣ. ΒΛΕΠΕ ΣΧΕΔΙΟ CD101 ΓΙΑ ΕΠΙΠΛΕΟΝ ΛΕΠΤΟΜΕΡΕΙΑ
ΣΤΗΝ ΑΦΑΙΡΕΣΗ ΔΙΚΤΥΩΝ ΟΦΕΛΕΙΩΝ ΤΟΥ ΠΕΔΙΟΥ.
G REQUEST WRITTEN APPROVAL OF CONTRACTING OFFICER
WHEN UTILITIES TO REMAIN IN SERVICE WILL BE TURNED OFF
TO FACILITATE WORK; PROVIDE MINIMUM 30 DAY NOTICE.
ΝΑ ΖΗΤΕΙΤΑΙ ΓΡΑΠΤΗ ΕΓΚΡΙΣΗ ΑΠΟ ΤΟΝ ΑΞΙΩΜΑΤΙΚΟ ΤΟΥ
ΕΡΓΟΥ ΟΤΑΝ ΔΙΚΤΥΑ ΟΦΕΛΕΙΩΝ ΠΟΥ ΘΑ ΠΑΡΑΜΕΙΝΟΥΝ ΣΕ
ΛΕΙΤΟΥΡΓΙΑ ΘΑ ΠΡΕΠΕΙ ΝΑ ΑΠΕΝΕΡΓΟΠΟΙΗΘΟΥΝ ΓΙΑ ΝΑ
ΔΙΕΥΚΟΛΥΝΟΥΝ ΤΙΣ ΕΡΓΑΣΙΕΣ, ΝΑ ΓΙΝΕΤΑΙ ΕΝΗΜΕΡΩΣΗ
ΤΟΥΛΑΧΙΣΤΟΝ 30 ΗΜΕΡΕΣ ΝΩΡΙΤΕΡΑ.
H DEVELOP, IMPLEMENT, AND FOLLOW A CONSTRUCTION /
DEMOLITION WASTE (CDW) MANAGEMENT PLAN
THROUGHOUT PROJECT IN COORDINATION WITH
INSTALLATION WASTE MANAGEMENT SERVICES.
ΝΑ ΑΝΑΠΤΥΧΘΕΙ, ΥΛΟΠΟΙΗΘΕΙ ΚΑΙ ΑΚΟΛΟΥΘΗΘΕΙ ΕΝΑ ΣΧΕΔΙΟ
ΔΙΑΧΕΙΡΙΣΗΣ ΑΠΟΒΛΗΤΩΝ ΚΑΤΑΣΚΕΥΗΣ/ΚΑΤΕΔΑΦΙΣΗΣ (CDW)
ΚΑΘΟΛΗ ΤΗ ΔΙΑΡΚΕΙΑ ΤΟΥ ΕΡΓΟΥ ΣΕ ΣΥΝΤΟΝΙΣΜΟ ΜΕ ΤΙΣ
ΥΠΗΡΕΣΙΕΣ ΕΓΚΑΤΑΣΤΑΣΕΩΝ ΔΙΑΧΕΙΡΙΣΗΣ ΑΠΟΒΛΗΤΩΝ.
I RECYCLE UNCONTAMINATED CONSTRUCTION MATERIALS
INCLUDING CONCRETE, STEEL, ALUMINUM, GYPSUM BOARD,
AND OTHERS AS APPLICABLE, IN ACCORDANCE WITH LOCAL
REGULATIONS, INSTALLATION PROCEDURES, AND CDW
MANAGEMENT PLAN.
ΝΑ ΑΝΑΚΥΚΛΩΝΟΝΤΑΙ ΤΑ ΜΗ ΜΟΛΥΣΜΕΝΑ ΚΑΤΑΣΚΕΥΑΣΤΙΚΑ
ΥΛΙΚΑ ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΤΩΝ ΣΚΥΡΟΔΕΜΑ, ΧΑΛΥΒΑΣ,
ΑΛΟΥΜΙΝΙΟ, ΓΥΨΟΣΑΝΙΔΕΣ, ΚΑΙ ΑΛΛΑ ΟΠΟΥ ΕΦΑΡΜΟΖΕΤΑΙ,
ΣΥΜΦΩΝΑ ΜΑ ΤΟΥΣ ΤΟΠΙΚΟΥΣ ΚΑΝΟΝΙΣΜΟΥΣ, ΤΙΣ ΔΙΑΔΙΚΑΣΙΕΣ
ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΤΟ ΣΧΕΔΙΟ ΔΙΑΧΕΙΡΙΣΗΣ CDW
J ELECTRICAL EQUIPMENT AND DEVICES, INCLUDING BUT NOT
LIMITED TO, LIGHT FIXTURES, LIGHTING DEVICES, PANEL
BOARDS, BATTERY SYSTEMS, RECEPTACLES, COVER PLATES,
AND RACEWAYS WITHIN THE AREA OF DEMOLITION MUST BE
DEENERGIZED AND REMOVED.
Ο ΗΛΕΚΤΟΡΛΟΓΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΚΑΙ ΣΥΣΚΕΥΕΣ,
ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΑΛΛΑ ΟΧΙ ΜΟΝΟ, ΦΩΤΙΣΤΙΚΩΝ,
ΣΥΣΚΕΥΩΝ ΦΩΤΙΣΜΟΥ, ΠΙΝΑΚΩΝ, ΣΥΣΤΗΜΑΤΩΝ ΜΠΑΤΑΡΙΩΝ,
ΔΟΧΕΙΩΝ, ΕΛΑΣΜΑΤΩΝ ΚΑΛΥΨΗΣ ΚΑΙ ΗΛΕΚΤΡΙΚΩΝ ΑΓΩΓΩΝ,
ΜΕΣΑ ΣΤΑ ΟΡΙΑ ΤΗΣ ΚΑΤΕΔΑΦΙΣΗΣ ΠΡΕΠΕΙ ΝΑ
ΑΠΕΝΕΡΓΟΠΟΙΕΙΤΑΙ ΚΑΙ ΝΑ ΑΦΑΙΡΕΙΤΑΙ.
K SALVAGE FIRE CONTROL PANEL, REMOVE AND TURN OVER TO
CONTRACTING OFFICE PRIOR TO COMMENCEMENT OF
DEMOLITION ACTIVITIES.
ΝΑ ΔΙΑΣΩΘΕΙ Ο ΠΙΝΑΚΑΣ ΕΛΕΓΧΟΥ ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ, ΝΑ
ΑΦΑΙΡΕΘΕΙ ΚΑΙ ΝΑ ΕΠΙΣΤΡΑΦΕΙ ΣΤΟΝ ΑΞΙΩΜΑΤΙΚΟ ΤΟΥ ΕΡΓΟΥ
ΠΡΙΝ ΤΗΝ ΕΝΑΡΞΗ ΤΩΝ ΕΡΓΩΝ ΚΑΤΕΔΑΦΙΣΗΣ.
L DEMOLISH BUILDING 4, FOUNDATIONS, ANCILLARY
EQUIPMENT, UTILITY CONNECTIONS, PIV, WALKWAYS,
PORTION OF RETAINING WALL AND SECURITY FENCE.
MAINTAIN FLIGHTLINE SECURITY WITH TEMPORARY FENCING.
ΝΑ ΚΑΤΕΔΑΦΙΣΤΕΙ ΤΟ ΚΤΙΡΙΟ 4, ΤΑ ΘΕΜΕΛΙΑ, Ο ΒΟΗΘΗΤΙΚΟΣ
ΕΞΟΠΛΙΣΜΟΣ, ΟΙ ΣΥΝΔΕΣΕΙΣ ΔΙΚΤΥΩΝ, ΟΙ ΣΤΥΛΙΣΚΟΙ ΜΕ ΒΑΝΑ
ΕΝΔΕΙΞΗΣ, ΟΙ ΠΕΖΟΔΡΟΜΟΙ, ΤΜΗΜΑ ΤΟΥ ΤΟΙΧΟΥ
ΑΝΤΙΣΤΗΡΙΞΗΣ ΚΑΙ Η ΠΕΡΙΦΡΑΞΗ ΑΣΦΑΛΕΙΑΣ. ΝΑ ΔΙΑΤΗΡΗΘΕΙ
Η ΑΣΦΑΛΕΙΑ ΤΩΝ ΑΕΡΟΔΙΑΔΡΟΜΩΝ ΜΕ ΠΡΟΣΩΡΙΝΗ
ΠΕΡΙΦΡΑΞΗ.
M DEMOLISH CONDUIT, CABLE, RACKS/CABINETS, CONTROL
UNITS, FACEPLATES, JACKS AND OTHER HARDWARE AND
EQUIPMENT ASSOCIATED WITH TELECOMMUNICATIONS AND
ESS THAT IS INTERNAL TO BUILDING. FOR CABLING COMING
FROM EXTERNAL OF BUILDING, SEE TELECOMMUNICATIONS
SITE DEMOLITION DRAWINGS.
ΝΑ ΚΑΤΕΔΑΦΙΣΤΟΥΝ ΑΓΩΓΟΙ, ΚΑΛΩΔΙΑ, ΣΧΑΡΕΣ/ΚΟΥΤΙΑ,
ΜΟΝΑΔΕΣ ΕΛΕΓΧΟΥ, ΕΛΑΣΜΑΤΑ ΠΡΟΣΤΑΣΙΑΣ, ΑΝΥΨΩΤΗΡΕΣ
ΚΑΙ ΑΛΛΑ ΑΝΤΙΚΕΙΜΕΝΑ ΚΑΙ ΕΞΟΠΛΙΣΜΟΣ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ
ΜΕ ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ KAI ΕSS ΕΝΤΟΣ ΤΟΥ ΚΤΙΡΙΟΥ. ΓΙΑ
ΚΑΛΩΔΙΩΣΗ ΠΟΥ ΕΡΧΕΤΑΙ ΑΠΟ ΤΟ ΕΞΩΤΕΡΙΚΟ ΤΟΥ ΚΤΙΡΙΟΥ,
ΒΛΕΠΕ ΣΧΕΔΙΑ ΚΑΤΕΔΑΦΙΣΕΩΝ ΠΕΔΙΟΥ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ.
N REMOVE AND DEMOLISH FIRE SUPPRESSION EQUIPMENT
INCLUDING BUT NOT LIMITED TO, PIPING, SPRINKLERS,
FITTINGS, HANGERS, AND OTHER APPURTENANCES.
ΝΑ ΑΦΑΙΡΕΘΕΙ ΚΑΙ ΝΑ ΚΑΤΕΔΑΦΙΣΤΕΙ ΕΞΟΠΛΙΣΜΟΣ
ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΑΛΛΑ ΟΧΙ ΜΟΝΟ,
ΣΩΛΗΝΩΣΕΩΝ, ΚΑΤΑΙΟΝΗΤΗΡΩΝ, ΠΡΟΣΑΡΜΟΓΕΩΝ,
ΣΥΣΤΗΜΑΤΩΝ ΚΡΕΜΑΣΗΣ ΚΑΙ ΑΛΛΩΝ ΣΥΣΚΕΥΩΝ.
3 REMOVE CONCRETE SIDEWALKS, CURBS, LANDINGS,
EQUIPMENT PADS, SCREEN WALLS, PLANTERS, STEPS,
RAMPS AND RAILINGS, AROUND PERIMETER OF BUILDING IN
THEIR ENTIRETY, REFER SHEETS CD101 FOR ADDITIONAL
GUIDANCE ON REMOVAL OF SITE APPURTENANCES
ΝΑ ΑΦΑΙΡΕΘΟΥΝ ΠΕΖΟΔΡΟΜΙΑ ΣΚΥΡΟΔΕΜΑΤΟΣ, ΚΡΑΣΠΕΔΑ,
ΠΛΑΤΥΣΚΑΛΑ, ΠΛΑΚΕΣ ΕΞΟΠΛΙΣΜΟΥ, ΤΟΙΧΟΙ ΕΜΠΟΔΙΣΜΟΥ
ΟΡΑΣΗΣ, ΚΟΥΤΙΑ ΦΥΤΕΥΣΗΣ, ΣΚΑΛΙΑ, ΡΑΜΠΕΣ ΚΑΙ
ΚΙΓΚΛΙΔΩΜΑΤΑ, ΕΞ ΟΛΟΚΛΗΡΟΥ ΣΤΗΝ ΠΕΡΙΟΧΗ ΤΗΣ
ΕΠΕΡΙΜΕΤΡΟΥ ΤΟΥ ΚΤΙΡΙΟΥ, ΒΛΕΠΕ ΣΧΕΔΙΟ CD101 ΓΙΑ
ΕΠΙΠΛΕΟΝ ΚΑΘΟΔΗΓΗΣΗ ΓΙΑ ΑΦΑΙΡΕΣΗ ΕΞΑΡΤΗΜΑΤΩΝ ΣΤΟ
ΠΕΔΙΟ
4 REMOVE ALL HVAC AND PLUMBING EQUIPMENT, CONTROLS,
DUCTWORK, PIPING, FANS IN ITS ENTIRETY. REMOVE
REFRIGERANT FROM ALL AIR CONDITIONING UNITS (PRAC-A,
PRAC-B, CRACU-1, C-1, C-2, HP-1, HP-2, HPOU-2, HP-3) AND
TURN OVER REFRIGERANT TO THE CONTRACTING OFFICER.
ΝΑ ΑΦΑΙΡΕΘΟΥΝ ΟΛΟΣ Ο ΕΞΟΠΛΙΣΜΟΣ HVAC ΚΑΙ ΟΙ ΑΝΤΛΙΕΣ,
ΟΙ ΔΙΑΚΟΠΤΕΣ ΕΛΕΓΧΟΥ, ΑΓΩΓΟΙ, ΣΩΛΗΝΩΣΕΙΣ, ΑΝΕΜΙΣΤΗΡΕΣ,
ΕΞ ΟΛΟΚΛΗΡΟΥ. ΝΑ ΑΦΑΙΡΕΘΟΥΝ ΤΑ ΨΥΚΤΙΚΑ ΑΠΟ ΟΛΕΣ ΤΙΣ
ΜΟΝΑΔΕΣ ΚΛΙΜΑΤΙΣΜΟΥ (PRAC-A, PRAC-B, CRACU-1, C-1, C-2,
HP-1, HP-2, HPOU-2, HP-3) ΚΑΙ ΝΑ ΕΠΙΣΤΡΑΦΟΥΝ ΣΤΟΝ
ΑΞΙΩΜΑΤΙΚΟ ΤΟΥ ΕΡΓΟΥ
1 BUILDING DEMOLITION PROJECT LIMITS, REFER TO CD101
FOR SITE DEMOLITION
ΟΡΙΑ ΕΡΓΟΥ ΚΑΤΕΔΑΦΙΣΗΣ ΚΤΙΡΙΟΥ, ΒΛΕΠΕ CD101 ΓΙΑ
ΚΑΤΕΔΑΦΙΣΕΙΣ ΣΤΟ ΠΕΔΙΟ
2 REMOVE EXISTING STRUCTURE IN ITS ENTIRETY INCLUDING
ROOF, CANOPIES, WALLS PARTITIONS, FIXTURES,
EQUIPMENT, PIPING, CONDUIT, FOUNDATIONS, FOOTINGS,
AND BELOW SLAB STRUCTURES
ΝΑ ΑΦΑΙΡΕΘΟΥΝ ΥΦΙΣΤΑΜΕΝΕΣ ΚΑΤΑΣΚΕΥΕΣ ΕΞ ΟΛΟΚΛΗΡΟΥ
ΣΥΜΠΕΡΙΛΑΜΒΑΝΟΜΕΝΟΥ ΣΚΕΠΩΝ, ΣΤΕΓΑΣΤΡΩΝ,
ΔΙΑΧΩΡΙΣΤΙΚΩΝ ΤΟΙΧΩΝ, ΦΩΤΙΣΤΙΚΩΝ, ΕΞΟΠΛΙΣΜΟΥ,
ΣΩΛΗΝΩΣΕΩΝ, ΑΓΩΓΩΝ, ΘΕΜΕΛΙΩΝ, ΠΕΔΙΛΩΝ ΚΑΙ
ΚΑΤΑΣΚΕΥΩΝ ΚΑΤΩ ΑΠΟ ΠΛΑΚΕΣ
0 5000 10000
MILLIMETRESSCALE 1:100
30001000
PLAN NORTH
ΚΑΤΟΨΗ ΒΟΡΡΑ
UPUP
A
2 3 4 5 6 7 8
450 7300 5025 7085 4595 7350 5525 6670 5285 450
B
C
D
DEMARC 2
DEMARC 1
TR G-1
UPS
ELEC
STAIR 1
MOTHERS
BREAK
RECYCLE
UPS
STAIR 2
MECH
RECEIVING
ELEV
N6 MAINTENANCE
QUARTER DECK
LOBBY
JAN
BUNK
N6 STOR
MENS
WOMENS
N6 EQUIPMENT
ROOM
SIPR CAFE
FIRE PROT
N6 CONF
N6 C3P
N6 ISSM
N6 MAINT
N6 ID
NIPR CAFE
8640 3395 7765 3915 3080 4270 5815 6500 5455
IT LOGISTICS
VEST
VEST
CORRIDOR
N6
5235 3475 7270 3805 6385 5575 3150 6305 2725
5850 7060 3555
885 2655 1740
R .O
R .O
R .O
11 11
865 600 4530 600 5130 4530 600
1045 1010 3080 600 1450 5910 5910 5310 1455
R.O.
1250 1640
R.O.
1250 1185
R.O.
1250 1640
R.O.
1250 1185
R.O.
1250 2030
R.O.
1250 195
4250 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 4250
R.O.
1250 845
R.O.
R.O.
R .O
R.O.
1250 1190
R.O.
1250 860
R.O.
3285 43370 3080
53240
50 TYP
TY
P
49735 3505
TYP
TY
P
TYP
1895 1500
2360 1270 2670 785 275
MIN
MIN
M
IN
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:0
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-101
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
G R
O U
N D
F
LO
O R
D
IM
EN
SI
O
N
AL
14089155
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Ι
ΣΟ
ΓΕ
ΙΟ
-Μ Ε Δ
ΙΑ
ΣΤ
ΑΣ
Ε
ΙΣ
DER
DPS
SCALE: 1 : 100A1
FLOOR PLAN - GROUND FLOOR - DIMENSIONAL
ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΙΣΟΓΕΙΟ - ΜΕ ΔΙΑΣΤΑΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A DOORS NOT DIMENSIONED MUST BE LOCATED 150MM FROM
NEAREST WALL CORNER. DOORS NOT LOCATED IMMEDIATELY
ADJACENT TO WALL CORNER MUST BE CENTERED BETWEEN
ADJACENT WALLS.
ΟΙ ΜΗ ΔΙΑΣΤΑΣΙΟΛΟΓΗΜΕΝΕΣ ΠΟΡΤΕΣ ΠΡΕΠΕΙ ΝΑ
ΤΟΠΟΘΕΤΗΘΟΥΝ 150ΧΙΛ ΑΠΟ ΤΗΝ ΠΛΗΣΙΕΣΤΕΡΗ ΓΩΝΙΑ
ΤΟΙΧΟΥ. ΟΙ ΠΟΡΤΕΣ ΠΟΥ ΔΕΝ ΕΙΝΑΙ ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΑΜΕΣΑ
ΠΡΟΣΑΡΤΗΜΕΝΕΣ ΣΤΗΝ ΓΩΝΙΑ ΤΟΥ ΤΟΙΧΟΥ ΠΡΕΠΕΙ ΝΑ
ΚΕΝΤΡΑΡΙΣΤΟΥΝ ΑΝΑΜΕΣΑ ΣΤΟΥΣ ΠΡΟΣΚΕΙΜΕΝΟΥΣ ΤΟΙΧΟΥΣ.
B DOORS IN ALUMINUM STOREFRONT SYSTEMS ARE LOCATED
PER STOREFRONT ELEVATIONS.
ΟΙ ΠΟΡΤΕΣ ΣΤΑ ΣΥΣΤΗΜΑΤΑ ΤΖΑΜΑΡΙΑΣ ΑΛΟΥΜΙΝΙΟΥ ΕΙΝΑΙ
ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΣΟΨΕΙΣ ΤΖΑΜΑΡΙΑΣ /
ΥΑΛΟΠΕΤΑΣΜΑΤΟΣ.
C REFER A-401 THRU A-403 FOR ENLARGED ROOM PLANS.
REFER A-411 THRU A-423 FOR ENLARGED VERTICAL
CIRCULATION SHEETS.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-401 ΕΩΣ Α-403 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΔΩΜΑΤΙΩΝ.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-411 ΕΩΣ Α-423 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΚΑΘΕΤΗΣ ΚΥΚΛΟΦΟΡΙΑΣ.
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
2 CAST-IN-PLACE CONCRETE PILASTER WITH LIQUID APPLIED
ELASTOMERIC COATING, EX-2
ΔΙΑΚΟΣΜΗΤΙΚΟΣ ΚΙΟΝΑΣ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΜΕ ΕΓΧΥΣΗ ΕΠΙ
ΤΟΠΟΥ ΜΕ ΕΦΑΡΜΟΓΗ ΥΓΡΗΣ ΕΛΑΣΤΟΜΕΡΟΥΣ ΕΠΙΣΤΡΩΣΗΣ, ΕΧ-2
3 CAST-IN-PLACE CONCRETE BASE WITH LIQUID APPLIED
ELASTOMERIC COATING, EX-1
ΣΟΒΑΤΕΠΙ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΜΕ ΕΓΧΥΣΗ ΕΠΙ ΤΟΠΟΥ ΜΕ
ΕΦΑΡΜΟΓΗ ΥΓΡΗΣ ΕΛΑΣΤΟΜΕΡΟΥΣ ΕΠΙΣΤΡΩΣΗΣ, ΕΧ-1
4 CAST-IN-PLACE CONCRETE FORM LINER WITH LIQUID APPLIED
ELASTOMERIC COATING, EX-3
ΑΝΑΓΛΥΦΟ ΚΑΛΟΥΠΙ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΜΕ ΕΓΧΥΣΗ ΕΠΙ ΤΟΠΟΥ ΜΕ
ΕΦΑΡΜΟΓΗ ΥΓΡΗΣ ΕΛΑΣΤΟΜΕΡΟΥΣ ΕΠΙΣΤΡΩΣΗΣ, ΕΧ-3
5 15mm WIDE X 25mm DEEP V SHAPED CONTROL JOINT, REFER
STRUCTURAL
ΑΝΤΙΣΕΙΣΜΙΚΟΣ ΑΡΜΟΣ ΣΧΗΜΑΤΟΣ V 15ΧΙΛ ΠΛΑΤΟΥΣ X 25ΧΙΛ
ΒΑΘΟΥΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΤΑΤΙΚΑ
UP DN
DN UP
A
2 3 4 5 6 7 8
B
C
D
N9 MAINTENANCE
STAIR 1
TR 1-1
UNCLASS CONF
MECH
STAIR 2
BREAK
N3 LNSC
ELEV
LNSC DIR
LNSC ANALYSIS
N9 OPEN OFFICE
N9 BCO
NETWORK DIST
AREA
N00 COMMAND
ELEC
TECH DIR
SN ENLIST
SEC MNGR
FIN ANLS
MENS
WOMENS
CORRIDOR
JAN
53190
400 7300 5025 7085 4595 7350 5525 6670 5285 400
1810 3240 3180 3180 3275 6350 4560 8595
4290 2720 9340 3060 11945 11905
11 11
1570 390
R .O
R .O
4200 600 3915 4515 4515 600 3915 600 3915 4515 4515 4515 600 3915 600 4200
R.O
2570 785
765 600 4530 600 4530 600 4530
7330 600 5910 5910 5310 1355
R .O
R .O
R.O.
R.O.
1250 1640
R.O.
1250 1185
R.O.
1250 1640
R.O.
1250 1185
R.O.
1250 2030
R.O.
1250 195
3335 43170 3130
49635 3555
R.O.
1250 75
R.O.
1250 285
R.O.
1250 2380
R.O.
1250 2320 885
R.O.
1250 845
R.O.
R.O.
1250 845
R.O.
1250 285
R.O.
1250 2380
0 1270 405
STORAGE
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:0
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-102
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
FI
R
ST
F
LO
O
R
D
IM
EN
SI
O N
AL
14089156
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Π
ΡΩ
ΤΟ
Σ Ο Ρ Ο Φ Ο Σ
-Μ Ε Δ
ΙΑ
ΣΤ
Α
ΣΕ
ΙΣ
DER
DPS
SCALE: 1 : 100A1 FLOOR PLAN - FIRST FLOOR - DIMENSIONAL - ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΠΡΩΤΟΣ ΟΡΟΦΟΣ - ΜΕ ΔΙΑΣΤΑΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A DOORS NOT DIMENSIONED MUST BE LOCATED 150MM FROM
NEAREST WALL CORNER. DOORS NOT LOCATED IMMEDIATELY
ADJACENT TO WALL CORNER MUST BE CENTERED BETWEEN
ADJACENT WALLS.
ΟΙ ΜΗ ΔΙΑΣΤΑΣΙΟΛΟΓΗΜΕΝΕΣ ΠΟΡΤΕΣ ΠΡΕΠΕΙ ΝΑ
ΤΟΠΟΘΕΤΗΘΟΥΝ 150ΧΙΛ ΑΠΟ ΤΗΝ ΠΛΗΣΙΕΣΤΕΡΗ ΓΩΝΙΑ
ΤΟΙΧΟΥ. ΟΙ ΠΟΡΤΕΣ ΠΟΥ ΔΕΝ ΕΙΝΑΙ ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΑΜΕΣΑ
ΠΡΟΣΑΡΤΗΜΕΝΕΣ ΣΤΗΝ ΓΩΝΙΑ ΤΟΥ ΤΟΙΧΟΥ ΠΡΕΠΕΙ ΝΑ
ΚΕΝΤΡΑΡΙΣΤΟΥΝ ΑΝΑΜΕΣΑ ΣΤΟΥΣ ΠΡΟΣΚΕΙΜΕΝΟΥΣ ΤΟΙΧΟΥΣ.
B DOORS IN ALUMINUM STOREFRONT SYSTEMS ARE LOCATED
PER STOREFRONT ELEVATIONS.
ΟΙ ΠΟΡΤΕΣ ΣΤΑ ΣΥΣΤΗΜΑΤΑ ΤΖΑΜΑΡΙΑΣ ΑΛΟΥΜΙΝΙΟΥ ΕΙΝΑΙ
ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΣΟΨΕΙΣ ΤΖΑΜΑΡΙΑΣ /
ΥΑΛΟΠΕΤΑΣΜΑΤΟΣ.
C REFER A-401 THRU A-403 FOR ENLARGED ROOM PLANS.
REFER A-411 THRU A-423 FOR ENLARGED VERTICAL
CIRCULATION SHEETS.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-401 ΕΩΣ Α-403 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΔΩΜΑΤΙΩΝ.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-411 ΕΩΣ Α-423 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΚΑΘΕΤΗΣ ΚΥΚΛΟΦΟΡΙΑΣ.
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
2 CAST-IN-PLACE CONCRETE BEAM, REFER STRUCTURAL
ΔΟΚΑΡΙ ΑΠΟ ΣΚΥΡΟΔΕΜΑ ΜΕ ΕΓΧΥΣΗ ΕΠΙ ΤΟΠΟΥ , ΑΝΑΤΡΕΞΤΕ
ΣΤΑ ΣΤΑΤΙΚΑ
DN
A
2 3 4 5 6 7 8
B
C
D
STAIR 1
STAIR 2
MECH
ELEV
CLASSIFIED
CONFERENCE
N9 TECH CONTROL
TR 2-1
N00 STOR
FLEET CYBER -
SECURE
COMM SECURITY
MATERIAL AREA
SSO OFFICE
FLEET CYBER -
EQUIP
ELEC
CORRIDOR
N00C KMI
N3 STOR
BREAK
ISSM
KMI STOR
FLEET CYBER -
CONF
N9 EQUIPMENT
ROOM
VESTIBULE
MENS
WOMENS
JAN
400 7300 5025 7085 4595 7350 5525 6670 5285 400
3530 3410 360 3750 1275 3810 3550 6470 4810 11225
5 75
375 16465 240 10570 3660 3075 7525
3320 1890 5155
NOO
WATCH CENTER
WATCH CMDR
2110 2025
4200 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 3915 600 4200
R.O.
2570 785
765 600 4530 600 4530 600 4530 545 6035 750 600 5310 600 5310 600 5310 600 755
3335 43170 3130
53190
49635 3555
800 2515 1025 950 2380 51
R.O.
1250 855
R.O.
R.O.
1250 1120
R.O.
1250 510
R.O.
585 585 R.O.
1250 2030
R.O.
R .O
R .O
R.O.
1250 1875
1270 2730
STORAGE
VEST
CLOSET
336B
MIN
445 2220 850
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:1
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-103
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
SE
C
O N
D F
LO
O
R
D
IM
EN
SI
O N
AL
14089157
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Δ Ε
ΥΤ
ΕΡ
Ο Σ Ο
ΡΟ
Φ Ο Σ
-Μ Ε
ΔΙ
Α
ΣΤ
ΑΣ
Ε
ΙΣ
DER
DPS
SCALE: 1 : 100A1 FLOOR PLAN - SECOND FLOOR - DIMENSIONAL - ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΔΕΥΤΕΡΟΣ ΟΡΟΦΟΣ - ΜΕ ΔΙΑΣΤΑΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A DOORS NOT DIMENSIONED MUST BE LOCATED 150MM FROM
NEAREST WALL CORNER. DOORS NOT LOCATED IMMEDIATELY
ADJACENT TO WALL CORNER MUST BE CENTERED BETWEEN
ADJACENT WALLS.
ΟΙ ΜΗ ΔΙΑΣΤΑΣΙΟΛΟΓΗΜΕΝΕΣ ΠΟΡΤΕΣ ΠΡΕΠΕΙ ΝΑ
ΤΟΠΟΘΕΤΗΘΟΥΝ 150ΧΙΛ ΑΠΟ ΤΗΝ ΠΛΗΣΙΕΣΤΕΡΗ ΓΩΝΙΑ
ΤΟΙΧΟΥ. ΟΙ ΠΟΡΤΕΣ ΠΟΥ ΔΕΝ ΕΙΝΑΙ ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΑΜΕΣΑ
ΠΡΟΣΑΡΤΗΜΕΝΕΣ ΣΤΗΝ ΓΩΝΙΑ ΤΟΥ ΤΟΙΧΟΥ ΠΡΕΠΕΙ ΝΑ
ΚΕΝΤΡΑΡΙΣΤΟΥΝ ΑΝΑΜΕΣΑ ΣΤΟΥΣ ΠΡΟΣΚΕΙΜΕΝΟΥΣ ΤΟΙΧΟΥΣ.
B DOORS IN ALUMINUM STOREFRONT SYSTEMS ARE LOCATED
PER STOREFRONT ELEVATIONS.
ΟΙ ΠΟΡΤΕΣ ΣΤΑ ΣΥΣΤΗΜΑΤΑ ΤΖΑΜΑΡΙΑΣ ΑΛΟΥΜΙΝΙΟΥ ΕΙΝΑΙ
ΤΟΠΟΘΕΤΗΜΕΝΕΣ ΣΥΜΦΩΝΑ ΜΕ ΤΙΣ ΠΡΟΣΟΨΕΙΣ ΤΖΑΜΑΡΙΑΣ /
ΥΑΛΟΠΕΤΑΣΜΑΤΟΣ.
C REFER A-401 THRU A-403 FOR ENLARGED ROOM PLANS.
REFER A-411 THRU A-423 FOR ENLARGED VERTICAL
CIRCULATION SHEETS.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-401 ΕΩΣ Α-403 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΔΩΜΑΤΙΩΝ.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΑΠΟ Α-411 ΕΩΣ Α-423 ΓΙΑ
ΜΕΓΕΘΥΜΕΝΑ ΣΧΕΔΙΑ ΚΑΘΕΤΗΣ ΚΥΚΛΟΦΟΡΙΑΣ.
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
UPUP
A
2 3 4 5 6 7 8
B
C
D
DEMARC 2
DEMARC 1
TR G-1
UPS
ELEC
STAIR 1
MOTHERS
BREAK
RECYCLE
UPS
STAIR 2
MECH
RECEIVING
ELEV
N6 MAINTENANCE
QUARTER DECK
LOBBY
JAN
BUNK
N6 STOR
MENS
WOMENS
N6 EQUIPMENT
ROOM
SIPR CAFE
FIRE PROT
N6 CONF
N6 C3P
N6 ISSM
A-202
A1
A-201
C1
A-202
B1
A-201
A1
A1 A-301
A1 A-301
C1 A-301
C1 A-301
A2 A-311
A1 A-312
A1 A-422
N6
NIPR CAFE
IT LOGISTICS
N6 MAINT
N6 ID
VEST
VEST
107CORRIDOR
A1 A-311
131A
1B
2 13
3B
4 13
130B130A
107B
103B
100B
B 4 1 1B
A 4 1 1A
A 4 1 1A
B 4 1 2B
B 4 1 2B
A 4 1 1A
B 4 1 2B
B 4 1 2B
A 4 1 1A
A 4 1 1A
0C
7A
3A
0A
120B
0A
A 4 2 1A
A-401 B1
A-425 A1
A-423 A1
A1 A-426
C 6 2 A
3A
11 11
B 4 1 1B
A 4 2 A
D 6 1 1A
C 4 1 A
A 4 1 1A
A 4 2 A
S 4 1 1B
A 6 2 A
B 4 1 2B
A 6 1 1A
A 4 1 1A
A 4 1 A
A 4 1 B
C 4 1 A
A 4 1 1A
A 4 1 1A
A 4 1 1A
A 4 2 A
A 4 1 1A A 4 1 1A A 4 1 1A
A-421 B1
A-402 A1
CLOSET
S 4 1 1B
B 4 1 2A B 4 1 2B
B 4 1 2B
W1 W1 W1 W1 W1 W1 W1 W1 W1
W1
W1W1
I-W1I-W1
A-502 C1 _________________________________
A-502 C2
A-501 B1
A-501 C2
A-501 A1
S 4 1 2B
2 33
W3
W4
TYP
S 4 1 1B
S 4 1 B
F 4 1 - F 4 1 -
F 4 1 - F 4 1 -
TYP
TYP
A-503 C1
SIM OH
A-501
A1 SIM OH
A-501 A3
A-501 B2
A-501 B3
A-501 C1
A-502 A1
A-502 A2
A-502 A4 _________________________________
A-502 B1 _________________________________
A-502 B5
A-502 B2 _________________________________
A-502 B3
A-501
C1 SIM
F 1 1 -
C 4
F 2 1 -
C 6
A 6
C 6
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:1
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-111
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
G R
O U
N D
F
LO
O R
AN
N O
TA
TI
VE
14089158
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Ι
ΣΟ
ΓΕ
ΙΟ
-Μ Ε Π
ΑΡ
Α
ΤΗ
ΡΗ
ΣΕ
ΙΣ
DER
DPS
SCALE: 1 : 100A1
FLOOR PLAN - GROUND FLOOR - ANNOTATIVE
ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΙΣΟΓΕΙΟ - ΜΕ ΠΑΡΑΤΗΡΗΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A REFER INTERIOR DESIGN DRAWINGS FOR CASEWORK
ELEVATIONS AND INTERIOR FINISHES.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΕΣΩΤΕΡΙΚΗΣ ΔΙΑΚΟΣΜΗΣΗΣ ΓΙΑ
ΟΨΕΙΣ ΕΠΙΠΛΩΣΗΣ ΚΑΙ ΕΣΩΤΕΡΙΚΑ ΤΕΛΕΙΩΜΑΤΑ.
B REFER SHEET A-601 FOR PARTITION TYPES.
ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601 ΓΙΑ ΤΥΠΟΥΣ ΧΩΡΙΣΜΑΤΩΝ
C WALL PARTITIONS SHALL BE TYPE A4, EXTEND TO
STRUCTURE ABOVE AND HAVE A STC RATING OF 45 UNLESS
NOTED OTHERWISE, REFER SHEET A-601
ΤΑ ΧΩΡΙΣΜΑΤΑ ΤΩΝ ΤΟΙΧΩΝ ΘΑ ΕΙΝΑΙ ΤΥΠΟΣ Α4, ΘΑ
ΕΠΕΚΤΕΙΝΟΝΤΑΙ ΜΕΧΡΙ ΤΗΝ ΚΑΤΑΣΚΕΥΗ ΑΝΩΘΕΝ ΚΑΙ ΘΑ
ΕΧΟΥΝ ΒΑΘΜΟ STC 45 ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601
D PROVIDE ACOUSTIC RATED TOP AND BOTTOM
TERMINATION AND SOUND ATTENUATION BATTS FOR NON-
RATED PARTITIONS, REFER SHEET A-601
ΠΡΟΜΗΘΕΥΣΤΕ ΜΟΝΩΣΗ ΣΕ ΡΟΛΟ ΜΕ ΗΧΗΤΙΚΗ ΑΠΟΣΒΕΣΗ
ΚΑΙ ΑΚΟΥΣΤΙΚΗ ΤΑΞΗ ΑΝΩ ΚΑΙ ΚΑΤΩ ΤΕΡΜΑΤΙΣΜΩΝ ΓΙΑ
ΧΩΡΙΣΜΑΤΑ ΧΩΡΙΣ ΤΑΞΙΝΟΜΗΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ
Α-601
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
2 SEMI-RECESSED FIRE EXTINGUISHER CABINET
ΗΜΙ-ΧΩΝΕΥΤΟ ΕΡΜΑΡΙΟ ΠΥΡΟΣΒΕΣΤΗΡΑ
3 BRACKET MOUNTED FIRE EXTINGUISHER CABINET
ΕΡΜΑΡΙΟ ΠΥΡΟΣΒΕΣΤΗΡΑ ΤΟΠΟΘΕΤΗΜΕΝΟ ΣΕ ΣΤΗΡΙΓΜΑ
4 TELECOMMUNICATIONS CABINET, REFER TELECOM
ΕΡΜΑΡΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ, ΑΝΑΤΡΕΞΤΕ ΣΤΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ
5 MECHANICAL EQUIPMENT, REFER MECHANICAL
ΜΗΧΑΝΟΛΟΓΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ
6 FURNITURE, REFER INTERIORS
ΕΠΙΠΛΩΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΗΝ ΕΣΩΤΕΡΙΚΗ ΔΙΑΚΟΣΜΗΣΗ
7 DUAL ELECTRIC WATER COOLER, REFER PLUMBING
ΔΙΠΛΟΣ ΗΛΕΚΤΡΙΚΟΣ ΨΥΚΤΗΣ ΝΕΡΟΥ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΥΔΡΑΥΛΙΚΑ
UP DN
A
2 3 4 5 6 7 8
B
C
D
N9 MAINTENANCE
STAIR 1
TR 1-1
UNCLASS CONF
MECH
STAIR 2
BREAK
N3 LNSC
ELEV
LNSC DIR
LNSC ANALYSIS
213 N9 OPEN OFFICE
N9 BCO
NETWORK DIST
AREA
N00 COMMAND
223ELEC
TECH DIR
SN ENLIST
SEC MNGR
FIN ANLS
A-202
A1
A-202
B1
A-201
A1
A1 A-301
A1 A-301
C1 A-301
A2 A-311
A1 A-312
A1 A-311
JAN
0B
0A
B 4 1 B
WOMENS
MENS
A-401 B2
A-421 C1
A-423 A2
A-425 A2
C 6 2 A
11 11
B 4 1 B
C 4 1 A
C 4 1 A
D 6 1 1A
B 4 1 B
A 4 2 A
A 4 2 A
A 4 1 1B
A-403 A1
D 6 1 1A D 6 1 1A
D 6 1 1A
D 6 1 1A
C 4 2 A
C 4 2 A
A 4 1 1A A 4 1 1A
W1 W1 W1 W1 W1 W1 W1 W1 W1
W1
W1
W1W1W1W1W1W1W1
W1
W1
L-12
A-503 C1
A-503 B1
A-503 A1
W5
W5
TYP
C1 A-512
F 4 1 - F 4 1 -
TYP
F 4 F 4 1 -
TYP
STORAGE
A-515 B1
A-515 C1
A-515 A1
A-503 C1
SIM OH
A-503 A2
A-503 A4
A-501 C1
SIM
A-501 C1
SIM
A-502 B5
SIM
A-201
C1
C 6C 6
A 6 1 A
C 4 2 - C 4 2 -
C 4 2 -
C 6 2 -
C 4 2 -
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:1
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-112
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
FI
R
ST
F
LO
O
R
AN
N
O
TA
TI
V
E
14089159
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Π
ΡΩ
ΤΟ
Σ Ο Ρ Ο Φ Ο Σ
-Μ Ε Π
ΑΡ
Α
ΤΗ
ΡΗ
ΣΕ
ΙΣ
DER
DPS
SCALE: 1 : 100A1
FLOOR PLAN - FIRST FLOOR - ANNOTATIVE
ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΠΡΩΤΟΣ ΟΡΟΦΟΣ - ΜΕ ΠΑΡΑΤΗΡΗΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A REFER INTERIOR DESIGN DRAWINGS FOR CASEWORK
ELEVATIONS AND INTERIOR FINISHES.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΕΣΩΤΕΡΙΚΗΣ ΔΙΑΚΟΣΜΗΣΗΣ ΓΙΑ
ΟΨΕΙΣ ΕΠΙΠΛΩΣΗΣ ΚΑΙ ΕΣΩΤΕΡΙΚΑ ΤΕΛΕΙΩΜΑΤΑ.
B REFER SHEET A-601 FOR PARTITION TYPES.
ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601 ΓΙΑ ΤΥΠΟΥΣ ΧΩΡΙΣΜΑΤΩΝ
C WALL PARTITIONS SHALL BE TYPE A4, EXTEND TO
STRUCTURE ABOVE AND HAVE A STC RATING OF 45 UNLESS
NOTED OTHERWISE, REFER SHEET A-601
ΤΑ ΧΩΡΙΣΜΑΤΑ ΤΩΝ ΤΟΙΧΩΝ ΘΑ ΕΙΝΑΙ ΤΥΠΟΣ Α4, ΘΑ
ΕΠΕΚΤΕΙΝΟΝΤΑΙ ΜΕΧΡΙ ΤΗΝ ΚΑΤΑΣΚΕΥΗ ΑΝΩΘΕΝ ΚΑΙ ΘΑ
ΕΧΟΥΝ ΒΑΘΜΟ STC 45 ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601
D PROVIDE ACOUSTIC RATED TOP AND BOTTOM
TERMINATION AND SOUND ATTENUATION BATTS FOR NON-
RATED PARTITIONS, REFER SHEET A-601
ΠΡΟΜΗΘΕΥΣΤΕ ΜΟΝΩΣΗ ΣΕ ΡΟΛΟ ΜΕ ΗΧΗΤΙΚΗ ΑΠΟΣΒΕΣΗ
ΚΑΙ ΑΚΟΥΣΤΙΚΗ ΤΑΞΗ ΑΝΩ ΚΑΙ ΚΑΤΩ ΤΕΡΜΑΤΙΣΜΩΝ ΓΙΑ
ΧΩΡΙΣΜΑΤΑ ΧΩΡΙΣ ΤΑΞΙΝΟΜΗΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ
Α-601
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
2 SEMI-RECESSED FIRE EXTINGUISHER CABINET
ΗΜΙ-ΧΩΝΕΥΤΟ ΕΡΜΑΡΙΟ ΠΥΡΟΣΒΕΣΤΗΡΑ
3 MECHANICAL EQUIPMENT, REFER MECHANICAL
ΜΗΧΑΝΟΛΟΓΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ
4 TELECOMMUNICATIONS CABINET, REFER TELECOM
ΕΡΜΑΡΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ, ΑΝΑΤΡΕΞΤΕ ΣΤΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ
5 FURNITURE, REFER INTERIORS
ΕΠΙΠΛΩΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΗΝ ΕΣΩΤΕΡΙΚΗ ΔΙΑΚΟΣΜΗΣΗ
6 PLUMBING EQUIPMENT, REFER PLUMBING
ΕΞΟΠΛΙΣΜΟΣ ΥΔΡΑΥΛΙΚΩΝ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΥΔΡΑΥΛΙΚΑ
7 PROVIDE 1 HOUR FIRE RATED WINDOW
ΠΡΟΜΗΘΕΥΣΤΕ ΠΑΡΑΘΥΡΟ ΜΕ ΠΥΡΑΝΤΙΣΤΑΣΗ ΜΙΑΣ ΩΡΑΣ
DNDN UP
A
2 3 4 5 6 7 8
B
C
D
STAIR 1
STAIR 2
MECH
ELEV
CLASSIFIED
CONFERENCE
304N9 TECH CONTROL
TR 2-1
N00 STOR
FLEET CYBER -
SECURE
COMM SECURITY
MATERIAL AREA
SSO OFFICE
FLEET CYBER -
EQUIP
ELEC
CORRIDOR
N00C KMI
N3 STOR
BREAK
ISSM
KMI STOR
N9 EQUIPMENT
ROOM
A-202
A1
A-201
C1
A-202
B1
A-201
A1
A1 A-301
A1 A-301
C1 A-301
C1 A-301
___________________________________________________________A2 A-311
A1 A-312
FLEET CYBER -
CONF
JAN
WOMENS
MENS
S 4 1 B
B 6 1 B
A 6 1 A
A 6 1 A
A 6 1 A
A 6 1 A
S 4 1 1B
S 4 1 1B
A 6 1 A
A 6 1 1A
A 6 1 A
A1 A-311
9B
9A
336A
4A
304B
VESTIBULE
335 A 6
1 A
A 6 1 A
A-425 C1
A-421 A2
A-423 A3
A 6 1 A
C 6 2 A
D 6 1 1A
D 6 1 1A
B 6 1 B
A 6 1 A
S 4 2 B
A 6 2 A
S 4 2 B
A 6 2 A
S 4 1 B
S 4 1 B
S 4 1 1B
A 6 1 1A
A 6 1 A A 6 1 A
S 4 1 1B
S 4 1 B
S 4 1 B S 4 1 B
A 6 1 A A 6 1 A
A 6 1 A
D 6 1 1A
A-403 A2
A-401
B1 SIM
NOO
D 6 1 1A
D 6 1 1A
S 4 1 B
A 6 1 1A
A 6 1 A
A 6 1 A
S 4 1 B
A 6 2 A A 6 2 A
WATCH CENTER
WATCH CMDR
D 6 1 1A
305B
5A
0A 6
2 A
S 4 1 1B
A 6 1 A
S 4 1 B
S 4 1 B
A 6 1 A
A-503 B2
A-504 B1
A-504 B2
A-504 B4
A-504 C3
A-504 C1
W2
W2
W2
W2 W2 W2W2W2W2 W2
A 6 1 1A
A 6 1 1A
S 4 1 B
A-551A1
F 4 1 - F 4 1 -
TYP
F 4 1 - F 4 1 -
TYP
336B
L-13
A 6 1 A
A-503 B4
A-503 B1
SIM
A-504 A1
A-504 A2 _________________________________
A-504 A4
A 6 1 A A 6 1 A
A-503 B2
SIM
VEST
CLOSET
336B
C 6 2 -
C 6 2 -
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
LEGEND
ΥΠΟΜΝΗΜΑ
RAISED ACCESS FLOORING
ΥΠΕΡΥΨΩΜΕΝΟ ΔΑΠΕΔΟ ΜΕ ΠΡΟΣΒΑΣΗ
WALK OFF MAT FLOORING
ΤΑΠΕΤΟ ΚΥΚΛΟΦΟΡΙΑΣ
PERFORATED FLOOR TILE
ΔΙΑΤΡΗΤΟ ΠΛΑΚΙΔΙΟ ΔΑΠΕΔΟΥ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:2
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-113
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
FL
O
O R
P
LA
N
SE
C
O N
D F
LO
O
R
AN
N
O
TA
TI
V
E
14089160
Κ
ΑΤ
Ο Ψ Η Ο
ΡΟ
Φ Ο Υ
-Δ Ε
ΥΤ
Ε
ΡΟ
Σ Ο
ΡΟ
Φ Ο Σ
-Μ Ε Π
ΑΡ
Α
ΤΗ
ΡΗ
ΣΕ
ΙΣ
DER
DPS
SCALE: 1 : 100A1
FLOOR PLAN - SECOND FLOOR - ANNOTATIVE
ΚΑΤΟΨΗ ΟΡΟΦΟΥ - ΔΕΥΤΕΡΟΣ ΟΡΟΦΟΣ - ΜΕ ΠΑΡΑΤΗΡΗΣΕΙΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A REFER INTERIOR DESIGN DRAWINGS FOR CASEWORK
ELEVATIONS AND INTERIOR FINISHES.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ ΕΣΩΤΕΡΙΚΗΣ ΔΙΑΚΟΣΜΗΣΗΣ ΓΙΑ
ΟΨΕΙΣ ΕΠΙΠΛΩΣΗΣ ΚΑΙ ΕΣΩΤΕΡΙΚΑ ΤΕΛΕΙΩΜΑΤΑ.
B REFER SHEET A-601 FOR PARTITION TYPES.
ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601 ΓΙΑ ΤΥΠΟΥΣ ΧΩΡΙΣΜΑΤΩΝ
C WALL PARTITIONS SHALL BE TYPE A4, EXTEND TO
STRUCTURE ABOVE AND HAVE A STC RATING OF 45 UNLESS
NOTED OTHERWISE, REFER SHEET A-601
ΤΑ ΧΩΡΙΣΜΑΤΑ ΤΩΝ ΤΟΙΧΩΝ ΘΑ ΕΙΝΑΙ ΤΥΠΟΣ Α4, ΘΑ
ΕΠΕΚΤΕΙΝΟΝΤΑΙ ΜΕΧΡΙ ΤΗΝ ΚΑΤΑΣΚΕΥΗ ΑΝΩΘΕΝ ΚΑΙ ΘΑ
ΕΧΟΥΝ ΒΑΘΜΟ STC 45 ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ Α-601
D PROVIDE ACOUSTIC RATED TOP AND BOTTOM
TERMINATION AND SOUND ATTENUATION BATTS FOR NON-
RATED PARTITIONS, REFER SHEET A-601
ΠΡΟΜΗΘΕΥΣΤΕ ΜΟΝΩΣΗ ΣΕ ΡΟΛΟ ΜΕ ΗΧΗΤΙΚΗ ΑΠΟΣΒΕΣΗ
ΚΑΙ ΑΚΟΥΣΤΙΚΗ ΤΑΞΗ ΑΝΩ ΚΑΙ ΚΑΤΩ ΤΕΡΜΑΤΙΣΜΩΝ ΓΙΑ
ΧΩΡΙΣΜΑΤΑ ΧΩΡΙΣ ΤΑΞΙΝΟΜΗΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΟ ΣΧΕΔΙΟ
Α-601
1 FACE OF IN-LINE PARTITIONS TO ALIGN, REFER PARTITION TYPES
FOR RESPECTIVE PARTITION CONSTRUCTION AND WIDTHS
ΤΟ ΠΡΟΣΩΠΟ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ ΠΟΥ ΒΡΙΣΚΟΝΤΑΙ ΣΕ ΣΕΙΡΑ ΝΑ
ΕΙΝΑΙ ΕΥΘΥΓΡΑΜΜΙΣΜΕΝΟ, ΑΝΑΤΡΕΞΤΕ ΣΤΟΥΣ ΤΥΠΟΥΣ
ΧΩΡΙΣΜΑΤΩΝ ΓΙΑ ΤΗΝ ΑΝΤΙΣΤΟΙΧΗ ΚΑΤΑΣΚΕΥΗ ΤΩΝ ΧΩΡΙΣΜΑΤΩΝ
ΚΑΙ ΤΑ ΠΛΑΤΗ ΤΟΥΣ
2 MECHANICAL EQUIPMENT, REFER MECHANICAL
ΜΗΧΑΝΟΛΟΓΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ
3 SEMI-RECESSED FIRE EXTINGUISHER CABINET
ΗΜΙ-ΧΩΝΕΥΤΟ ΕΡΜΑΡΙΟ ΠΥΡΟΣΒΕΣΤΗΡΑ
4 TELECOMMUNICATIONS CABINET, REFER TELECOM
ΕΡΜΑΡΙΟ ΤΗΛΕΠΙΚΟΙΝΩΝΙΩΝ, ΑΝΑΤΡΕΞΤΕ ΣΤΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ
5 DUAL ELECTRIC WATER COOLER, REFER PLUMBING
ΔΙΠΛΟΣ ΗΛΕΚΤΡΙΚΟΣ ΨΥΚΤΗΣ ΝΕΡΟΥ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΥΔΡΑΥΛΙΚΑ
6 FURNITURE, REFER INTERIORS
ΕΠΙΠΛΩΣΗ, ΑΝΑΤΡΕΞΤΕ ΣΤΗΝ ΕΣΩΤΕΡΙΚΗ ΔΙΑΚΟΣΜΗΣΗ
7 PROVIDE 1 HOUR FIRE RATED TRANSLUCENT PANEL
ΠΡΟΜΗΘΕΥΣΤΕ ΗΜΙΔΙΑΦΑΝΟ ΠΑΝΕΛ ΜΕ ΠΥΡΑΝΤΙΣΤΑΣΗ ΜΙΑΣ
ΩΡΑΣ
F
A
2 3 4 5 6 7 8
B
C
D
DEMARC 2
DEMARC 1
TR G-1
UPS
ELEC
STAIR 1
MOTHERS
RECYCLE
UPS
STAIR 2
MECH
RECEIVING
ELEV
N6 MAINTENANCE
QUARTER DECK
LOBBY
JAN
BUNK
N6 STOR
MENS
WOMENS
N6 EQUIPMENT
ROOM
SIPR CAFE
FIRE PROT
N6 CONF
N6 C3P
N6 ISSM
N6 ID
N6
NIPR CAFE
CORRIDOR
IT LOGISTICS
BREAK
N6 MAINT
VEST
VEST
A-402 A3
A-401 A1
CLOSET
A1 A-521
B5 A-521
B5 A-521
C1 A-512
A1 A-521
A1 A-521
B5 A-521
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
DIFFUSER, SEE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
ΣΤΟΜΙΟ ΠΡΟΣΑΓΩΓΗΣ, ΒΛΕΠΕ
ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
RETURN AIR GRILLE, SEE MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION
ΣΤΟΜΙΟ ΕΠΙΣΤΡΟΦΗΣ ΑΕΡΑ, ΒΛΕΠΕ
ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
ELECTRICAL LIGHT FIXTURES, REFER ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION
ΗΛΕΚΤΡΙΚΑ ΦΩΤΙΣΤΙΚΑ ΣΩΜΑΤΑ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
SUSPENDED GRID SYSTEM FOR
ACOUSTICAL PANEL CEILING
ΑΝΑΡΤΟΥΜΕΝΟ ΣΥΣΤΗΜΑ ΚΑΝΑΒΟΥ ΓΙΑ
ΠΑΝΕΛ ΟΡΟΦΗΣ ΟΡΥΚΤΩΝ ΙΝΩΝ
EXIT SIGNAGE, SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL
INFORMATION
ΣΗΜΑΝΣΗ ΕΞΟΔΟΥ, ΒΛΕΠΕ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
GYPSUM BOARD CEILING AS SCHEDULED
ΟΡΟΦΗ ΓΥΨΟΣΑΝΙΔΑΣ ΟΠΩΣ ΣΤΟΝ ΠΙΝΑΚΑ
REMOVABLE LINEAR BAFFLE STYLE
CEILING
ΑΦΑΙΡΟΥΜΕΝΗ ΟΡΟΦΗ ΑΠΟ ΑΝΑΡΤΗΜΕΝΑ
ΓΡΑΜΜΙΚΑ ΣΤΟΙΧΕΙΑ
600 x 600 CEILING ACCESS PANEL 600 x 600 ΠΑΝΕΛ ΠΡΟΣΒΑΣΗΣ ΟΡΟΦΗΣ
SPRINKLERS, REFER TO FIRE PROTECTION
DRAWINGS
ΚΑΤΑΙΟΝΗΤΗΡΕΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ
ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:3
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-121
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
G
R O
U N
D F
LO
O
R
14089161
Α Ν
ΕΣ
ΤΡ
ΑΜ
Μ Ε Ν Η Κ Α
ΤΟ
Ψ Η Ο Ρ Ο Φ Η Σ
-Ι
ΣΟ
ΓΕ
ΙΟ
DER
DPS
SCALE: 1 : 100A1
REFLECTED CEILING PLAN - GROUND FLOOR
ΑΝΕΣΤΡΑΜΜΕΝΗ ΚΑΤΟΨΗ ΟΡΟΦΗΣ - ΙΣΟΓΕΙΟ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A REFER INTERIOR ROOM FINISH SCHEDULES FOR FINISHES
AND HEIGHTS ASSOCIATED WITH CEILINGS.
ΑΝΑΤΡΕΞΤΕ ΣΤΟΝ ΠΙΝΑΚΑ ΤΕΛΕΙΩΜΑΤΩΝ ΕΣΩΤΕΡΙΚΩΝ
ΔΩΜΑΤΙΩΝ ΓΙΑ ΤΕΛΕΙΩΜΑΤΑ ΚΑΙ ΥΨΗ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ ΜΕ
ΤΙΣ ΟΡΟΦΕΣ
B REFER ELECTRICAL DRAWINGS FOR LIGHTING FIXTURE
DESCRIPTIONS.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΠΕΡΙΓΡΑΦΕΣ
ΦΩΤΙΣΤΙΚΩΝ ΣΩΜΑΤΩΝ
C FIRE SPRINKLER HEAD LOCATIONS WILL BE PROVIDED BY
THE CONTRACTOR AND ARE NOT INDICATED ON THE
CEILING PLANS.
ΟΙ ΘΕΣΕΙΣ ΤΩΝ ΚΕΦΑΛΩΝ ΤΩΝ ΚΑΤΑΙΩΝΙΣΤΗΡΩΝ ΦΩΤΙΑΣ ΘΑ
ΠΑΡΑΣΧΕΘΟΥΝ ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΚΑΙ ΔΕΝ
ΥΠΟΔΕΙΚΝΥΟΝΤΑΙ ΣΤΙΣ ΚΑΤΟΨΕΙΣ ΟΡΟΦΗΣ
D PREFINISHED SUPPLY/RETURN DIFFUSERS PAINTED TO
MATCH CEILING FINISH.
ΤΑ ΠΡΟΚΑΤΑΣΚΕΥΑΣΜΕΝΑ ΣΤΟΜΙΑ
ΠΡΟΣΑΓΩΓΗΣ/ΕΠΙΣΤΡΟΦΗΣ ΝΑ ΒΑΦΟΥΝ ΓΙΑ ΝΑ ΤΑΙΡΙΑΖΟΥΝ
ΜΕ ΤΑ ΤΕΛΙΚΑ ΧΡΩΜΑΤΑ ΤΗΣ ΟΡΟΦΗΣ
E MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF
ACOUSTICAL TILES TO BALANCE WIDTHS AT OPPOSITE
PERIMETER EDGES OF EACH CEILING. AVOID USING LESS-
THAN-HALF WIDTH TILES AT PERIMETER.
ΜΕΤΡΗΣΤΕ ΚΑΘΕ ΠΕΡΙΟΧΗ ΟΡΟΦΗΣ ΚΑΙ ΚΑΘΟΡΙΣΤΕ ΤΗ
ΔΙΑΤΑΞΗ ΤΩΝ ΠΛΑΚΙΔΙΩΝ ΟΡΥΚΤΩΝ ΙΝΩΝ ΓΙΑ ΝΑ
ΙΣΟΡΡΟΠΗΣΕΤΕ ΤΑ ΠΛΑΤΗ ΤΩΝ ΑΝΤΙΘΕΤΩΝ ΠΕΡΙΜΕΤΡΙΚΩΝ
ΑΚΡΩΝ ΚΑΘΕ ΟΡΟΦΗΣ. ΑΠΟΦΥΓΕΤΕ ΝΑ ΧΡΗΣΙΜΟΠΟΙΗΤΕ
ΠΛΑΚΙΔΙΑ ΜΕ ΠΛΑΤΟΣ ΛΙΓΟΤΕΡΟ ΑΠΌ ΤΟ ΜΙΣΟ ΣΤΗΝ
ΠΕΡΙΜΕΤΡΟ.
F COORDINATE PLACEMENT OF CEILING MOUNTED FIXTURES
AND ACCESSORIES BETWEEN TRADES. ITEMS SMALLER
THAN ONE (1) CEILING TILE ARE TO BE CENTERED WITHIN
ONE (1) TILE, UNLESS NOTED OTHERWISE.
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΣΩΜΑΤΩΝ ΠΟΥ ΑΝΑΡΤΩΝΤΑΙ
ΣΤΗΝ ΟΡΟΦΗ ΚΑΙ ΕΞΑΡΤΗΜΑΤΩΝ ΜΕΤΑΞΥ ΤΩΝ ΔΙΑΦΟΡΩΝ
ΕΙΔΙΚΟΤΗΤΩΝ. ΑΝΤΙΚΕΙΜΕΝΑ ΜΙΚΡΟΤΕΡΑ ΑΠΟ (1) ΠΛΑΚΙΔΙΟ
ΟΡΟΦΗΣ ΘΑ ΚΕΝΤΡΑΡΟΝΤΑΙ ΜΕΣΑ ΣΕ ΕΝΑ (1) ΠΛΑΚΙΔΙΟ,
ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ
G PROVIDE CONTROL JOINTS (CJ) IN GYPSUM BOARD
CEILINGS AS FOLLOWS: 15200MM MAX. IN CEILINGS WITH
PERIMETER RELIEF, 9100MM MAX. IN CEILINGS WITHOUT
PERIMETER RELIEF UNLESS NOTED OTHERWISE.
ΝΑ ΠΑΡΕΧΕΤΕ ΑΡΜΟΥΣ ΣΥΣΤΟΛΗΣ (CJ) ΣΤΙΣ ΟΡΟΦΕΣ ΑΠΟ
ΓΥΨΟΣΑΝΙΔΑ ΟΠΩΣ ΠΑΡΑΚΑΤΩ: 15200 ΧΙΛΙΟΣΤΑ ΜΕΓΙΣΤΟ ΣΕ
ΟΡΟΦΕΣ ΜΕ ΠΕΡΙΜΕΤΡΙΚΟ ΑΝΑΓΛΥΦΟ, 9100 ΧΙΛΙΟΣΤΑ
ΜΕΓΙΣΤΟ ΣΕ ΟΡΟΦΕΣ ΧΩΡΙΣ ΠΕΡΙΜΕΤΡΙΚΟ ΑΝΑΓΛΥΦΟ,
ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ
H ALL CEILING HEIGHTS TO BE AT 2750MM AFF UNLESS NOTED
OTHERWISE, .
ΟΛΑ ΤΑ ΥΨΗ ΟΡΟΦΗΣ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΤΑ 2750 ΧΙΛΙΟΣΤΑ
ΠΑΝΩ ΑΠΟ ΤΟ ΤΕΛΙΚΟ ΔΑΠΕΔΟ ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ
ΔΙΑΦΟΡΕΤΙΚΑ
J AT CONDITIONS WHERE LIGHTS, SPRINKLERS, OR OTHER
DEVICES ARE COINCIDENT ON PLAN, FIXTURES ARE AT
DIFFERENT VERTICAL LOCATIONS. REFER TO ELECTRICAL
AND FIRE PROTECTION FOR FIXTURE MOUNTING HEIGHTS
ΣΕ ΣΥΝΘΗΚΕΣ ΟΠΟΥ ΦΩΤΑ, ΚΑΤΑΙΩΝΙΣΤΗΡΕΣ Ή ΑΛΛΕΣ
ΣΥΣΚΕΥΕΣ ΣΥΜΠΙΠΤΟΥΝ ΣΤΗΝ ΚΑΤΟΨΗ, ΤΑ ΦΩΤΙΣΤΙΚΑ
ΣΩΜΑΤΑ ΠΡΕΠΕΙ ΝΑ ΕΙΝΑΙ ΣΕ ΔΙΑΦΟΡΕΤΙΚΕΣ ΚΑΤΑΚΟΡΥΦΕΣ
ΘΕΣΕΙΣ. ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΗΛΕΚΤΟΛΟΓΙΚΑ ΚΑΙ
ΠΥΡΟΠΡΟΣΤΑΣΙΑ ΓΙΑ ΤΗΝ ΠΡΟΣΑΡΤΗΣΗ ΤΟΥ ΥΨΟΥΣ ΤΗΣ
ΒΑΣΗΣ
1 OPEN TO STRUCTURE ABOVE
ΑΝΟΙΧΤΟ ΣΤΗΝ ΚΑΤΑΣΚΕΥΗ ΑΝΩΘΕΝ
2 CABLE TRAY, REFER TELECOM
ΣΧΑΡΑ ΚΑΛΩΔΙΩΝ, ΑΝΑΤΡΕΞΤΕ ΣΤΙΣ ΤΗΛΕΠΙΚΟΙΝΩΝΙΕΣ
3 MECHANICAL EQUIPMENT, REFER MECHANICAL
ΜΗΧΑΝΟΛΟΓΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΜΗΧΑΝΟΛΟΓΙΚΑ
RCP LEGEND - ΥΠΟΜΝΗΜΑ RCP
F
A
2 3 4 5 6 7 8
B
C
D
N9 MAINTENANCE
STAIR 1
TR 1-1
UNCLASS CONF
MECH
STAIR 2
BREAK
N3 LNSC
ELEV
LNSC DIR
LNSC ANALYSIS
N9 OPEN OFFICE
N9 BCO
NETWORK DIST
AREA
N00 COMMAND
ELEC
TECH DIR
SN ENLIST
SEC MNGR
FIN ANLS
MENS
WOMENS
CORRIDOR
JAN
A-401 A2
A-404 A1
A1 A-521
A1 A-521
A2
A-521
B5 A-521
GENERAL NOTES:
ΓΕΝΙΚΕΣ ΠΑΡΑΤΗΡΗΣΕΙΣ:
SHEET KEYED NOTES:
ΠΑΡΑΤΗΡΗΣΕΙΣ ΣΧΕΔΙΟΥ:
DIFFUSER, SEE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION
ΣΤΟΜΙΟ ΠΡΟΣΑΓΩΓΗΣ, ΒΛΕΠΕ
ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
RETURN AIR GRILLE, SEE MECHANICAL
DRAWINGS FOR ADDITIONAL INFORMATION
ΣΤΟΜΙΟ ΕΠΙΣΤΡΟΦΗΣ ΑΕΡΑ, ΒΛΕΠΕ
ΜΗΧΑΝΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
ELECTRICAL LIGHT FIXTURES, REFER ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION
ΗΛΕΚΤΡΙΚΑ ΦΩΤΙΣΤΙΚΑ ΣΩΜΑΤΑ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
SUSPENDED GRID SYSTEM FOR
ACOUSTICAL PANEL CEILING
ΑΝΑΡΤΟΥΜΕΝΟ ΣΥΣΤΗΜΑ ΚΑΝΑΒΟΥ ΓΙΑ
ΠΑΝΕΛ ΟΡΟΦΗΣ ΟΡΥΚΤΩΝ ΙΝΩΝ
EXIT SIGNAGE, SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL
INFORMATION
ΣΗΜΑΝΣΗ ΕΞΟΔΟΥ, ΒΛΕΠΕ
ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΕΠΙΠΛΕΟΝ
ΠΛΗΡΟΦΟΡΙΕΣ
GYPSUM BOARD CEILING AS SCHEDULED
ΟΡΟΦΗ ΓΥΨΟΣΑΝΙΔΑΣ ΟΠΩΣ ΣΤΟΝ ΠΙΝΑΚΑ
REMOVABLE LINEAR BAFFLE STYLE
CEILING
ΑΦΑΙΡΟΥΜΕΝΗ ΟΡΟΦΗ ΑΠΟ ΑΝΑΡΤΗΜΕΝΑ
ΓΡΑΜΜΙΚΑ ΣΤΟΙΧΕΙΑ
600 x 600 CEILING ACCESS PANEL 600 x 600 ΠΑΝΕΛ ΠΡΟΣΒΑΣΗΣ ΟΡΟΦΗΣ
SPRINKLERS, REFER TO FIRE PROTECTION
DRAWINGS
ΚΑΤΑΙΟΝΗΤΗΡΕΣ, ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΣΧΕΔΙΑ
ΠΥΡΟΠΡΟΣΤΑΣΙΑΣ
R
EG
IS
TERED ARCH ITEC
T
S
TA T E O F T EXA
S
C H
R
IS
TO PHER M .
S U
R L
E S
23 63 8
D
C
B
1 2 3 4 5
1615269
DWG
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.
SCALE:
N62470-21-C-0005
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
AS NOTED
N
AV
SU
PP
AC
T
SO
U
D A
BA
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
D
EP
AR
TM
E N
T O
F
TH
E N
AV
Y
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
C O
M M
AN
D
A
FIRE PROTECTION
N O
R
FO
LK
, V
A A
TL
AN
TI
C
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
D
C
B
A
1 2 3 4 5
RICHARD STEPHENS
TRUEWORTHY,PE / STELMASZEK,RA
PL
O
T
DA
TE
/T
IM
E:
7/
/ 2
3:
:3
PM
C :\U se rs
\fa ng ue l\D oc um en ts
\R ev it
TE
M P\
P1
-D
1- A_
R
_l uk e.
fa ng ue .rv t
14 JUL 2021
RECEIVED BY JACOBIE TISDALE
AND STEVE PARK VIA EMAIL
A-122
CMS LDF MAH
P1
C O
M M
U N
IC
A
TI
O
N S
C E
N
TE
RS
O
U D
A B
AY
, G
R
EE
C E
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
FI
R
ST
F
LO
O R
14089162
Α Ν
ΕΣ
ΤΡ
ΑΜ
Μ Ε Ν Η Κ Α
ΤΟ
Ψ Η Ο
ΡΟ
Φ Η Σ
-Π
ΡΩ
ΤΟ
Σ Ο Ρ Ο Φ Ο Σ
DER
DPS
SCALE: 1 : 100A1
REFLECTED CEILING PLAN - FIRST FLOOR
ΑΝΕΣΤΡΑΜΜΕΝΗ ΚΑΤΟΨΗ ΟΡΟΦΗΣ - ΠΡΩΤΟΣ ΟΡΟΦΟΣ 0 5000 10000
MILLIMETRESSCALE 1:100
30001000
A REFER INTERIOR ROOM FINISH SCHEDULES FOR FINISHES
AND HEIGHTS ASSOCIATED WITH CEILINGS.
ΑΝΑΤΡΕΞΤΕ ΣΤΟΝ ΠΙΝΑΚΑ ΤΕΛΕΙΩΜΑΤΩΝ ΕΣΩΤΕΡΙΚΩΝ
ΔΩΜΑΤΙΩΝ ΓΙΑ ΤΕΛΕΙΩΜΑΤΑ ΚΑΙ ΥΨΗ ΠΟΥ ΣΧΕΤΙΖΟΝΤΑΙ ΜΕ
ΤΙΣ ΟΡΟΦΕΣ
B REFER ELECTRICAL DRAWINGS FOR LIGHTING FIXTURE
DESCRIPTIONS.
ΑΝΑΤΡΕΞΤΕ ΣΤΑ ΗΛΕΚΤΡΟΛΟΓΙΚΑ ΣΧΕΔΙΑ ΓΙΑ ΠΕΡΙΓΡΑΦΕΣ
ΦΩΤΙΣΤΙΚΩΝ ΣΩΜΑΤΩΝ
C FIRE SPRINKLER HEAD LOCATIONS WILL BE PROVIDED BY
THE CONTRACTOR AND ARE NOT INDICATED ON THE
CEILING PLANS.
ΟΙ ΘΕΣΕΙΣ ΤΩΝ ΚΕΦΑΛΩΝ ΤΩΝ ΚΑΤΑΙΩΝΙΣΤΗΡΩΝ ΦΩΤΙΑΣ ΘΑ
ΠΑΡΑΣΧΕΘΟΥΝ ΑΠΟ ΤΟΝ ΚΑΤΑΣΚΕΥΑΣΤΗ ΚΑΙ ΔΕΝ
ΥΠΟΔΕΙΚΝΥΟΝΤΑΙ ΣΤΙΣ ΚΑΤΟΨΕΙΣ ΟΡΟΦΗΣ
D PREFINISHED SUPPLY/RETURN DIFFUSERS PAINTED TO
MATCH CEILING FINISH.
ΤΑ ΠΡΟΚΑΤΑΣΚΕΥΑΣΜΕΝΑ ΣΤΟΜΙΑ
ΠΡΟΣΑΓΩΓΗΣ/ΕΠΙΣΤΡΟΦΗΣ ΝΑ ΒΑΦΟΥΝ ΓΙΑ ΝΑ ΤΑΙΡΙΑΖΟΥΝ
ΜΕ ΤΑ ΤΕΛΙΚΑ ΧΡΩΜΑΤΑ ΤΗΣ ΟΡΟΦΗΣ
E MEASURE EACH CEILING AREA AND ESTABLISH LAYOUT OF
ACOUSTICAL TILES TO BALANCE WIDTHS AT OPPOSITE
PERIMETER EDGES OF EACH CEILING. AVOID USING LESS-
THAN-HALF WIDTH TILES AT PERIMETER.
ΜΕΤΡΗΣΤΕ ΚΑΘΕ ΠΕΡΙΟΧΗ ΟΡΟΦΗΣ ΚΑΙ ΚΑΘΟΡΙΣΤΕ ΤΗ
ΔΙΑΤΑΞΗ ΤΩΝ ΠΛΑΚΙΔΙΩΝ ΟΡΥΚΤΩΝ ΙΝΩΝ ΓΙΑ ΝΑ
ΙΣΟΡΡΟΠΗΣΕΤΕ ΤΑ ΠΛΑΤΗ ΤΩΝ ΑΝΤΙΘΕΤΩΝ ΠΕΡΙΜΕΤΡΙΚΩΝ
ΑΚΡΩΝ ΚΑΘΕ ΟΡΟΦΗΣ. ΑΠΟΦΥΓΕΤΕ ΝΑ ΧΡΗΣΙΜΟΠΟΙΗΤΕ
ΠΛΑΚΙΔΙΑ ΜΕ ΠΛΑΤΟΣ ΛΙΓΟΤΕΡΟ ΑΠΌ ΤΟ ΜΙΣΟ ΣΤΗΝ
ΠΕΡΙΜΕΤΡΟ.
F COORDINATE PLACEMENT OF CEILING MOUNTED FIXTURES
AND ACCESSORIES BETWEEN TRADES. ITEMS SMALLER
THAN ONE (1) CEILING TILE ARE TO BE CENTERED WITHIN
ONE (1) TILE, UNLESS NOTED OTHERWISE.
ΣΥΝΤΟΝΙΣΤΕ ΤΗΝ ΤΟΠΟΘΕΤΗΣΗ ΣΩΜΑΤΩΝ ΠΟΥ ΑΝΑΡΤΩΝΤΑΙ
ΣΤΗΝ ΟΡΟΦΗ ΚΑΙ ΕΞΑΡΤΗΜΑΤΩΝ ΜΕΤΑΞΥ ΤΩΝ ΔΙΑΦΟΡΩΝ
ΕΙΔΙΚΟΤΗΤΩΝ. ΑΝΤΙΚΕΙΜΕΝΑ ΜΙΚΡΟΤΕΡΑ ΑΠΟ (1) ΠΛΑΚΙΔΙΟ
ΟΡΟΦΗΣ ΘΑ ΚΕΝΤΡΑΡΟΝΤΑΙ ΜΕΣΑ ΣΕ ΕΝΑ (1) ΠΛΑΚΙΔΙΟ,
ΕΚΤΟΣ ΑΝ ΑΝΑΦΕΡΕΤΑΙ ΔΙΑΦΟΡΕΤΙΚΑ
G…
This is the start of the file's text. The full file is on GovTribe.