ATT H 1561956spc2of2.pdf
PDF 5 MB Posted
- Solicitation number
- N6247020R4011
About this file
This solicitation seeks proposals for an Indefinite Delivery Indefinite Quantity Multiple Award Construction Contract for projects located primarily at Rota, Spain and worldwide. The Naval Facilities Engineering Command will award multiple IDIQ contracts for design-build and design-bid-build construction services including general building, civil, mechanical and electrical construction. Award is anticipated by September 2020 with a five-year base period of performance and options to extend work for up to 30 months. Offerors must have prior experience with overseas military construction projects. Small businesses are encouraged to compete.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WORK ORDER NO.
At the
PREPARED BY:
Architectural: Mechanical:
Civil: Electrical:
Structural:
APPROVED BY:
Specifications:
For Commander, NAVFAC:
Date:
Submitted By: Date:
UNCLASSIFIED/FOR OFFICIAL USE ONLY
Help Note All fields can be edited. If you have trouble selecting a field, either use the tab key or click "highlight fields" in Acrobat 7. Fields that are not needed can be selected and deleted. Tool tips with "additional field" can be deleted or changed. The contract number can also be deleted or changed.
ashepard Image ashepard Image
P-811 Port Operations Facilities 1561956
PROJECT TABLE OF CONTENTS
DI VI SI ON 00 - PROCUREMENT AND CONTRACTI NG REQUI REMENTS
00 01 15 LIST OF DRAWINGS
00 73 04 SUPPLEMENTARY CONDITIONS FOR PROJECTS IN MEDITERRANEAN
AREA
DI VI SI ON 01 - GENERAL REQUI REMENTS
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 20 00.00 20 PRICE AND PAYMENT PROCEDURES
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 30 01.00 22 DESIGN, PROCUREMENT, AND INSTALLATION OF FURNITURE,
FIXTURES, AND EQUIPMENT
01 32 17.00 20 COST-LOADED NETWORK ANALYSIS SCHEDULES (NAS)
01 33 00 SUBMITTAL PROCEDURES
01 33 29 SUSTAINABILITY REPORTING
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 35 40.00 20 ENVIRONMENTAL MANAGEMENT
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 42 15 METRIC MEASUREMENTS
01 45 00.00 20 QUALITY CONTROL
01 45 35 SPECIAL INSPECTIONS
01 50 00.00 22 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS
01 58 00 PROJECT IDENTIFICATION
01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT
01 78 00 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
01 78 24.00 20 FACILITY ELECTRONIC OPERATION AND MAINTENANCE SUPPORT
INFORMATION (eOMSI)
01 91 00.15 TOTAL BUILDING COMMISSIONING
DI VI SI ON 02 - EXI STI NG CONDI TI ONS
02 41 00 DEMOLITION
02 82 16.00 20 ENGINEERING CONTROL OF ASBESTOS CONTAINING MATERIALS
02 83 13.00 20 LEAD IN CONSTRUCTION
02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs
AND MERCURY
DI VI SI ON 03 - CONCRETE
03 30 00 CAST-IN-PLACE CONCRETE
03 52 16 LIGHTWEIGHT INSULATING CONCRETE
DI VI SI ON 04 - MASONRY
04 20 00 UNIT MASONRY
DI VI SI ON 05 - METALS
05 12 00 STRUCTURAL STEEL
05 30 00 STEEL DECKS
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 33 METAL LADDERS
PROJECT TABLE OF CONTENTS Page 1
05 52 00 METAL RAILINGS
DI VI SI ON 06 - WOOD, PLASTI CS, AND COMPOSI TES
06 10 00 ROUGH CARPENTRY
06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
06 61 16 SOLID SURFACING FABRICATIONS
DI VI SI ON 07 - THERMAL AND MOI STURE PROTECTI ON
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 11 13 BITUMINOUS DAMPPROOFING
07 13 53 ELASTOMERIC SHEET WATERPROOFING
07 16 50 CEMENTITIOUS WATERPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 21 16 MINERAL FIBER BLANKET INSULATION
07 22 00 ROOF AND DECK INSULATION
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 32 13 ROOF TILES
07 54 19 POLYVINYL-CHLORIDE ROOFING
07 60 00 FLASHING AND SHEET METAL
07 81 00 SPRAY-APPLIED FIREPROOFING
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DI VI SI ON 08 - OPENI NGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 31 00 ACCESS DOORS AND PANELS
08 33 23 OVERHEAD COILING DOORS
08 39 54 BLAST RESISTANT DOORS
08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 56 53 BLAST RESISTANT TEMPERED GLASS WINDOWS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL AND DOOR LOUVERS
DI VI SI ON 09 - FI NI SHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 24 23 CEMENT STUCCO
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC, QUARRY, AND GLASS TILING
09 51 00 ACOUSTICAL CEILINGS
09 65 00 RESILIENT FLOORING
09 90 00 PAINTS AND COATINGS
09 96 00 HIGH-PERFORMANCE COATINGS
DI VI SI ON 10 - SPECI ALTI ES
10 11 00 VISUAL DISPLAY UNITS
10 14 00.10 EXTERIOR SIGNAGE
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 13 WIRE MESH PARTITIONS
10 22 39 FOLDING PANEL PARTITIONS
10 28 13 TOILET ACCESSORIES
PROJECT TABLE OF CONTENTS Page 2
10 44 16 FIRE EXTINGUISHERS
10 51 13 METAL LOCKERS
10 51 14 METAL MINI LOCKERS
10 56 13 HEAVY-DUTY STEEL SHELVING
DI VI SI ON 11 - EQUI PMENT
11 53 00 LABORATORY EQUIPMENT AND FUMEHOODS
DI VI SI ON 12 - FURNI SHI NGS
12 24 13 ROLLER WINDOW SHADES
12 36 00 EPOXY RESIN COUNTERTOPS
12 48 13 ENTRANCE FLOOR MATS AND FRAMES
DI VI SI ON 13 - SPECI AL CONSTRUCTI ON
13 48 00 SEISMIC BRACING FOR MISCELLANEOUS EQUIPMENT
DI VI SI ON 14 - CONVEYI NG EQUI PMENT
14 21 23 ELECTRIC TRACTION PASSENGER ELEVATORS
DI VI SI ON 21 - FI RE SUPPRESSI ON
21 13 13.00 20 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 30 00 FIRE PUMPS
DI VI SI ON 22 - PLUMBI NG
22 00 00 PLUMBING, GENERAL PURPOSE
22 07 19.00 40 PLUMBING PIPING INSULATION
22 15 14.00 40 GENERAL SERVICE COMPRESSED-AIR SYSTEMS, LOW PRESSURE
22 33 30.00 10 SOLAR WATER HEATING EQUIPMENT
DI VI SI ON 23 - HEATI NG, VENTI LATI NG, AND AI R CONDI TI ONI NG ( HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING
CONTROL SYSTEMS
23 21 13.00 20 LOW TEMPERATURE WATER (LTW) HEATING SYSTEM
23 23 00 REFRIGERANT PIPING
23 81 00.00 20 UNITARY AIR CONDITIONING EQUIPMENT
23 82 00.00 20 TERMINAL HEATING UNITS
DI VI SI ON 25 - I NTEGRATED AUTOMATI ON
25 05 11.01 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS - HVAC
25 05 11.02 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS -
LIGHTING
25 05 11.03 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS -
ELECTRONIC SECURITY SYSTEMS
25 05 11.04 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS -
ELEVATORS
PROJECT TABLE OF CONTENTS Page 3
25 05 11.05 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS - FIRE
ALARM
25 05 11.06 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS - AMI
25 08 10 UTILITY MONITORING AND CONTROL SYSTEM TESTING
DI VI SI ON 26 - ELECTRI CAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 05 48.00 10 SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT
26 08 00 APPARATUS INSPECTION AND TESTING
26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS
26 13 00 SF6/HIGH-FIREPOINT FLUIDS INSULATED PAD-MOUNTED SWITCHGEAR
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 27 14.00 20 ELECTRICITY METERING
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 32 13.00 20 SINGLE OPERATION GENERATOR SETS
26 35 43 SOLID STATE FREQUENCY CONVERTER
26 36 23.00 20 AUTOMATIC TRANSFER SWITCHES
26 41 00 LIGHTNING PROTECTION SYSTEM
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DI VI SI ON 27 - COMMUNI CATI ONS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
27 21 00.00 20 INTERCOMMUNICATION SYSTEM
27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS
DI VI SI ON 28 - ELECTRONI C SAFETY AND SECURI TY
28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING
28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS)
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
DI VI SI ON 31 - EARTHWORK
31 11 00 CLEARING AND GRUBBING
31 23 00.00 20 EXCAVATION AND FILL
31 31 16.13 CHEMICAL TERMITE CONTROL
DI VI SI ON 32 - EXTERI OR I MPROVEMENTS
32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID
PAVEMENTS
32 05 33 LANDSCAPE ESTABLISHMENT
32 11 23 AGGREGATE BASE COURSES
32 12 13 BITUMINOUS TACK AND PRIME COATS
32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
32 31 13 CHAIN LINK FENCES
32 92 19 SEEDING
32 93 00 EXTERIOR PLANTS
DI VI SI ON 33 - UTI LI TI ES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
PROJECT TABLE OF CONTENTS Page 4
33 30 00 SANITARY SEWERAGE
33 32 16 PACKAGED UTILITY WASTEWATER PUMPING STATIONS
33 40 00 STORM DRAINAGE UTILITIES
33 71 01 OVERHEAD TRANSMISSION AND DISTRIBUTION
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
DI VI SI ON 34 - TRANSPORTATI ON
34 71 13.16 VEHICLE CRASH BARRIERS
DI VI SI ON 41 - MATERI AL PROCESSI NG AND HANDLI NG EQUI PMENT
41 22 13.15 20-TON OVERHEAD ELECTRIC TRAVELING BRIDGE CRANE
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 5
THIS PAGE INTENTIONALLY LEFT BLANK
PROJECT TABLE OF CONTENTS Page 6
SECTION 11 53 00
LABORATORY EQUIPMENT AND FUMEHOODS
05/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH)
ACGIH-2097 (2013) Industrial Ventilation: A Manual of Recommended Practice (Metric)
ASTM INTERNATIONAL (ASTM)
ASTM A1008/A1008M (2016) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
ASTM B221M (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 45 (2015; TIA 15-1) Standard on Fire Protection for Laboratories Using Chemicals
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;
TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;
TIA 17-11; TIA 17-12; TIA 17-13; TIA
17-14) National Electrical Code
1.2 RELATED WORK SPECIFIED IN OTHER SECTIONS
Provide final utility connections and utility service to equipment including waste, under Sections 23 03 00.00 20 BASIC MECHANICAL MATERIALS
AND METHODS; 22 00 00 PLUMBING SYSTEMS; 26 00 00.00 20 BASIC ELECTRICAL
MATERIALS AND METHODS; and 26 20 00 INTERIOR DISTRIBUTION SYSTEM.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
SECTION 11 53 00 Page 1
Laboratory equipment and fume hood layout; G
SD-03 Product Data
Fumehood assembly; G
Include descriptive literature, technical data sheets, and diagrams.
SD-04 Samples
Exterior hood paint; G
SD-06 Test Reports
Fumehood test; G
SD-08 Manufacturer's Instructions
Fumehood assembly
SD-10 Operation and Maintenance Data
Fumehood assembly, Data Package 2; G
Submit in accordance with Section 01 78 23 OPERATION AND
MAINTENANCE DATA.
1.4 SUBMITTAL REQUIREMENTS
1.4.1 Hood Paint
Submit color chips of exterior hood paint. Submit at least five colors which are standard with the manufacturer.
1.4.2 Drawing Requirements
Show pertinent installation layout. Indicate details of construction and rough-in requirements.
1.4.3 Tests
Submit fumehood test reports required by ACGIH-2097 .
PART 2 PRODUCTS
2.1 MATERIALS, COMPONENTS, AND SPECIAL DESIGN REQUIREMENTS
2.1.1 Aluminum Alloy
ASTM B221M equivalent in ultimate tensile, yield, and shear strengths to Alloy 6063-T5 or 6063-T6.
2.1.2 Carbon Steel
ASTM A1008/A1008M , cold rolled sheets, commercial bright finish.
SECTION 11 53 00 Page 2
2.1.3 Stainless Steel
No 4 satin finish including welds and fabricated surfaces. Provide Type 302, 304, or 316 alloy unless otherwise specified. Provide minimum thickness of 1.5 mm, except 1.8 mm thick for working surface.
2.1.4 Fiberglass
Manufacturer standard.
2.1.5 Fumehood Design
Design, calculate face velocities, and test fume hoods in accordance with ACGIH-2097 , Laboratory fume hoods, auxiliary systems, and associated equipment shall meet the requirements of NFPA 70 and NFPA 45 .
2.1.6 Hood Static Pressure Loss
With the sash in full-open position the static pressure loss through the fumehood shall not exceed 13 mm water gage when operating at 23 mpm, 22 mm water gage at 30 mpm, 29 mm water gage at 38 mpm. For hoods equipped with bypass, the static pressure loss and exhaust volume shall remain relatively constant (within 5 percent) regardless of sash position.
2.1.7 Electrical Devices
Prewired at the factory to a common, integral junction box to provide easy exterior connection and disconnection.
2.2 UNITS
2.2.1 Fumehood Assembly, Constant Volume
Constant volume, configuration, enclosed unit mounted on base cabinet;
exterior dimensions maximum 1245 mm wide (across face) by 750 mm deep (front to back by 2400 mm high; interior working area at least 900 mm wide by 600 mm deep by 1195 mm high.
2.2.1.1 Hood Interior, Including Working Surface
Fiberglass, with interior vertical joints and intersections of vertical surface with working surface having an approximate 20 mm radius.
2.2.1.2 Baffle
Adjustable, with moving parts resistant to corrosion, removable for cleaning.
2.2.1.3 Lighting Fixtures
Vapor proof, fluorescent or LED, with cool white lamps and switch, providing 800 lux on working area. Locate switch for fixture on exterior of hood frame, or in recess of base cabinet. Provide sealed safety glass window barrier between interior working and fixture spaces, and access for tube replacement exterior to hood interior working area.
2.2.1.4 Blower Switch
Single-pole, 115-volt, 60-Hz, with pilot light. Locate switch in hood
SECTION 11 53 00 Page 3 frame or in recess of base cabinet.
2.2.1.5 Duct Stub
Collar size suitable for ductwork indicated. Finish of areas that may come in direct contact with fumes shall be same material and finish as hood interior.
PART 3 EXECUTION
3.1 INSTALLATION
Install units at locations indicated. Conform to installation provisions and the ACGIH-2097 including provision for an adequate supply of tempered make-up air to meet the air flow requirements of fume hood(s). Provide interlocks for controls and alarms to maintain the required air balance between hood interiors and the room.
3.2 POSTED OPERATING INSTRUCTIONS
Provide in accordance with the requirements in Section 23 03 00.00 20
BASIC MECHANICAL MATERIALS AND METHODS.
3.3 FIELD QUALITY CONTROL
3.3.1 Inspection
Examine each unit for visual defects, operation and conformance to specifications.
3.3.2 Tests
Test each unit to ensure that the equipment is operational and conforms to specification requirements. Field tests for fume hood operation and performance shall meet the requirements of ACGIH-2097 .
-- End of Section --
SECTION 11 53 00 Page 4
SECTION 12 24 13
ROLLER WINDOW SHADES
08/17
PART 1 GENERAL
1.1 GENERAL REQUIREMENTS
Provide roller window shades, complete with necessary brackets, fittings, and hardware as indicated. Mount and operate equipment in accordance with manufacturer's instructions. Windows to receive a shade must be completely covered.
a. Submit drawings showing plans, elevations, sections, product details, installation details, operational clearances, wiring diagrams and relationship to adjacent work. Include the use of same room designations as indicated on the drawings.
b. Provide manufacturer's data composed of catalog cuts, brochures, product information, and operating and maintenance instructions on each product to be used. Include styles, profiles and features.
c. Furnish samples of each type and color of roller shade fabric and roller shade channel. Shade material shall be minimum 150 by 150 mm in size. Mark face of material to indicate interior faces.
d. Mock up: Install shade in area designated by Contracting Officer. Do not proceed with remaining work until the Contracting Officer approves workmanship and operation. Re-work mock-up as required to produce acceptable work. The approved shade can be used in installation.
e. Submit fire resistance data, flame spread and smoke contribution data.
1.2 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM G21 (2015) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 701 (2015) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS)Indoor Advantage
SECTION 12 24 13 Page 1
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
UL 325 (2017) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES
SD-02 Shop Drawings
Installation; G
SD-03 Product Data
Window Shades; G
SD-04 Samples
Window Shades; G
Shade Materials; G
SD-06 Test Reports
Window Shades
SD-07 Certificates
Indoor Air Quality
SD-08 Manufacturer's Instructions
Window Shades
SD-10 Operation and Maintenance Data
Window Shades
SD-11 Closeout Submittals
Recycled Content for various fiber components; S
Indoor Air Quality for roller window shades; S
Warranty; G
SECTION 12 24 13 Page 2
1.4 CERTIFICATES
1.4.1 Indoor Air Quality Certifications
1.4.1.1 Roller Window Shades
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide validation by other third-party program that products meet the requirements of this paragraph. Provide current product certification documentation from certification body.
1.5 QUALITY ASSURANCE
1.5.1 Qualifications
1.5.1.1 Manufacturer's Qualifications
Obtain motor-controlled roller shades through one source from a single manufacturer with a minimum of twenty years experience and minimum of three projects of similar scope and size in manufacturing products comparable to those specified in this section.
1.5.1.2 Installer's Qualifications
Installer trained and certified by the manufacturer with a minimum of ten years experience in installing products comparable to those specified in this section.
1.5.2 Flammability Requirements
Passes in accordance with NFPA 701 small and large-scale vertical burn.
Materials tested must be identical to products proposed for use.
1.5.3 Electrical Requirements
NFPA Article 100 listed and labeled in accordance with UL 325 or other testing agency acceptable to authorities having jurisdiction, marked for intended use, and tested as a system. Individual testing of components will not be acceptable in lieu of system testing.
1.5.4 Anti-Microbial Requirements
'No Growth' per ASTM G21 results for fungi ATCC9642, ATCC 9644, ATCC9645.
1.6 DELIVERY, STORAGE, AND HANDLING
Deliver components to the jobsite in the manufacturer's original packaging with the brand or company name, item identification, and project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 10 degrees C. Do not open containers until needed for installation unless verification inspection is required.
1.7 WARRANTY
Provide 10 year minimum limited warranty.
SECTION 12 24 13 Page 3
PART 2 PRODUCTS
2.1 WINDOW SHADES
Roller tube must operate smoothly and be of sufficient diameter and thickness to prevent excessive deflection. Provide brackets that are appropriate for outside mount. The shade cloth must meet the performance described in NFPA 701 , small scale test. Treat steel features for corrosion resistance.
Provide Various Fiber Components with a minimum of 60 percent recycled content. Provide data identifying percentage of recycled content for various fiber components.
Provide certification of indoor air quality for roller window shades.
2.1.1 Light Filtering Shades (RS1)
Provide light filtering window shades to conform with the following:
a. Roller tube must be extruded aluminum or steel. Diameter, wall thickness, and material to be selected by the manufacturer to accommodate the shade size. Provide roller idler assembly of molded nylon and zinc-plated steel pin. Sliding pin must allow easy installation and removal of roller. Fabric must be connected to the roller tube with double sided adhesive specifically developed to attach coated textiles to metal to eliminate horizontal impressions in fabric or attached with a spline lock system.
b. Fascia must be L-shaped aluminum extrusion to conceal shade roller without requiring exposed fasteners of any kind. Color and finish to be selected from manufacturer's full range.
c. Provide polyester light filtering fabric with PVC coating with openness factor of 5 percent. Provide color, pattern, and texture for metal and shade as indicated.
d. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component or adjustment of motor without requiring removal of brackets and end or center supports. Provide shade hardware constructed of minimum 3 mm thick plated steel or heavier as required to support 150 percent of the full weight of each shade.
e. Manual Operated Chain Drive Hardware must provide for universal, regular and offset drive capacity, allowing drive chain to fall at front, rear or non-offset for all shade drive end brackets. Universal offset must be adjustable for future change. Provide positive mechanical engagement of drive mechanism to shade roller tube. The drive bracket must be fully integrated with all accessories. Drive chain must be #10 stainless steel chain rated to 33 kg minimum breaking strength.
2.1.2 Motorized Room Darkening Shades (RS2)
Provide combination shade units consisting of one roller with shade type to match light filtering type RS1 and one roller with room darkening (black-out) window shades designed to eliminate all visible light gaps
SECTION 12 24 13 Page 4 when shades are fully closed, and conform with the following:
a. Roller tube must be aluminum, controlled by crank operated gear box with steel rods. Provide shop fabricated light traps, consisting of a head box to house the shade roller, and U-shaped channels to serve as guides for the shade along the sides and to receive the bottom edge of the shade along the sill.
b. Provide light trap made of sheet steel having a minimum thickness of
0.85 mm (22 gauge) or anodized, extruded, aluminum. The legs of the channels must be not less than 44 mm long and separated by the minimum distance that will permit free operation of the shade. Edges of light trap coming into contact with the shade cloth must be smooth pile light seal. The exposed face of the head box must be hinged or removable for access to the shade roller. The interior or unexposed surfaces of the light trap must have a finish coat of flat black enamel. The exposed portions of the light trap must have a factory-applied priming coat of gray paint.
c. Cloth must be of type for blackout purposes. Make the shade from a single piece of canvas duck cloth laminated to vinyl. When not finished with a selvage, the vertical edges of the shade must be bound or hemmed using a high-grade thread. Make needle holes lightproof by applying a suitable filler.
d. Fit the bottom edge of the shade with a steel operating bar. Shades will engage positively with bottom rail through operating bar or chain pull. Paint bars with flat black enamel. Make pull cords of beaded chain having not less than 335 N breaking strength.
2.1.3 Motorized Transparent Plastic Window Shades (RS3)
Provide dual transparent plastic window shades for control tower windows.
Shades must be at least 0.125 mm thick, color as indicated, body dyed, and supported by rollers at constant tension.
a. Shade material #1 (Basis of Design - manufacturer: Plastic View, model #: F72 SR)
1. Visible light transmission equal to 4 percent.
2. Glare reduction equal to 95 percent.
3. Visible light reflection equal to 4 percent.
4. Shading coefficient equal to 0.39.
5. Solar heat gain coefficient equal to 0.34.
6. Solar energy transmission equal to 16 percent.
7. Solar energy reflected equal to 20 percent.
8. Solar energy absorption equal to 64 percent.
9. Solar energy rejection equal to 66 percent.
b. Shade material #2 (Basis of Design - manufacturer: Plastic View, model #: DS 8 SR)
1. Visible light transmission equal to 8 percent.
2. Glare reduction equal to 91 percent.
3. Visible light reflection equal to 8 percent.
4. Shading coefficient equal to 0.41.
5. Solar heat gain coefficient equal to 0.36.
6. Solar energy transmission equal to 19 percent.
7. Solar energy reflected equal to 21 percent.
SECTION 12 24 13 Page 5
8. Solar energy absorption equal to 60 percent.
9. Solar energy rejection equal to 64 percent.
c. Provide shades with a flat bottom bar, dull black with full width metal hemline, minimum of 26 gauge. Black plastic caps will be provided on each end of hemline cover.
d. Shades must be mounted on a minimum of 44.5 mm diameter corrosion resistant metal wrapped roller. The rollers must be spring loaded, single piece barrel with a safety cotter key type retainer installed through both ends with pins and washers to prevent roller from falling out of mounting brackets. Constant tension in shades is required.
The shade roller shall have brushes that remove dust from the shade as it is rolled up but does not hinder up and down operation.
e. Provide mounting brackets with a 57 mm resting ledge. Roll of direction of material must be as directed by the shade manufacturer.
f. Provide lock pulleys consisting of a roller and a spring return side action cam cord grip.
g. Provide cord direction change pulley used to route shade cord around obstructions where they exist. Pulleys must be positioned in direct line with cord outlet on metal hemline.
h. Provide front and back fascia consisting of aluminum extrusion that conceals rollers and operating mechanism and attaches without exposed fasteners. Color and finish to be selected from manufacturer's full range.
i. Motors must be hard-wired, wired into the building electrical system plug-in to standard ac electrical outlets. The position of the motor and electrical connection must be right side of roller, based on the hand of the user facing the shade from inside, unless otherwise indicated on drawings.
j. Activation Controls of Shades:
(1) Wall mounted controls: key pads are able to electronically set and reconfigure shade open and close limits, shade preset positions, system groups and system subgroups at the control without rewiring and without access to the Electronic Drive Unit.
k. Low voltage switching is required.
l. Operating function: Stop and hold shade at any position.
m. Provide the following options: Low Voltage System. Power failure memory for the life of the systems which protects presets.
2.1.4 Motorized Light Filtering Shades (RS4)
Provide light filtering window shades to conform with the following:
a. Roller tube must be extruded aluminum or steel. Diameter, wall thickness, and material to be selected by the manufacturer to accommodate the shade size. Provide roller idler assembly of molded nylon and zinc-plated steel pin. Sliding pin must allow easy installation and removal of roller. Fabric must be connected to the
SECTION 12 24 13 Page 6 roller tube with double sided adhesive specifically developed to attach coated textiles to metal to eliminate horizontal impressions in fabric or attached with a spline lock system.
b. Fascia must be L-shaped aluminum extrusion to conceal shade roller without requiring exposed fasteners of any kind. Color and finish to be selected from manufacturer's full range.
c. Provide polyester light filtering fabric with PVC coating with openness factor of 3 percent. Provide color, pattern, and texture for metal and shade as indicated.
d. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component or adjustment of motor without requiring removal of brackets and end or center supports. Provide shade hardware constructed of minimum 3 mm thick plated steel or heavier as required to support 150 percent of the full weight of each shade.
e. Motors must be hard-wired, wired into the building electrical system plug-in to standard ac electrical outlets. The position of the motor and electrical connection must be right side of roller, based on the hand of the user facing the shade from inside, unless otherwise indicated on drawings.
f. Activation Controls of Shades:
(1) Wall mounted controls: key pads are able to electronically set and reconfigure shade open and close limits, shade preset positions, system groups and system subgroups at the control without rewiring and without access to the Electronic Drive Unit.
g. Low voltage switching is required.
h. Operating function: Stop and hold shade at any position.
i. Provide the following options: Low Voltage System. Power failure memory for the life of the systems which protects presets.
2.2 COLOR
Provide color, pattern and texture for metal and shade materialsas indicated. Color listed is not intended to limit the selection of equal colors from other manufacturers. Openness factor of shade fabric must be as indicated.
PART 3 EXECUTION
3.1 FIELD MEASUREMENTS
After becoming familiar with details of the work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the work.
3.2 INSTALLATION
Do not install building construction materials that show visual evidence of biological growth.
SECTION 12 24 13 Page 7
Perform installation in accordance with the approved detail drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units.
Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installation until completion of room painting and finishing operations.
3.3 CLEAN-UP
Upon completion of the installation, clean window treatments and adjust them for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate metal parts from direct contact with concrete, mortar, or dissimilar metals. Ensure shades installed in recessed pockets can be removed without disturbing the pocket. The entire shade, when retracted, must be contained inside the pocket. For shades installed outside the jambs and mullions, overlap each jamb and mullion 20 mm or more when the jamb and mullion sizes permit. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.
SECTION 12 24 13 Page 8
SECTION 12 36 00
EPOXY RESIN COUNTERTOPS
08/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM D3801 (2010) Standard Test Method for Measuring the Comparative Burning Characteristics of Solid Plastics in a Vertical Position
ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics
ASTM D635 (2014) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position
ASTM D648 (2018) Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position
ASTM D695 (2010) Standard Test Method for Compressive Properties of Rigid Plastics
ASTM D696 (2016) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30 degrees C With a Vitreous Silica Dilatometer
ASTM D785 (2008) Rockwell Hardness of Plastics and Electrical Insulating Materials
ASTM D790 (2017) Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
ASTM D792 (2013) Density and Specific Gravity (Relative Density) of Plastics by Displacement
ASTM E84 (2018) Standard Test Method for Surface Burning Characteristics of Building Materials
SECTION 12 36 00 Page 1
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS)Indoor Advantage
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)
SCAQMD Rule 1168 (2017) Adhesive and Sealant Applications
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Fabrication; G
Installation Drawings; G
SD-03 Product Data
Epoxy Resin; G
Adhesives; G
Fasteners; G
Joint Sealants; G
SD-04 Samples
Countertop; G
Backsplash; G
Manufacturer's Standard Color Charts; G
SD-07 Certificates
Indoor Air Quality
SD-08 Manufacturer's Instructions
SECTION 12 36 00 Page 2
Manufacturer's Instructions
SD-11 Closeout Submittals
Indoor Air Quality for Countertop Products; S
Indoor Air Quality for Joint Sealants; S
1.3 CERTIFICATIONS
1.3.1 Indoor Air Quality Certification
Submit required indoor air quality certifications in one submittal package.
1.3.1.1 Countertop Products
Provide countertop products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide validation by other third-party program that products meet the requirements of this paragraph. Provide current product certification documentation from certification body. Products must meet emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).
1.3.1.2 Adhesives and Sealants
Provide laminate and wood member adhesives, mounting and stone adhesives, and joint sealant products certified to meet either emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type) or VOC content requirements of SCAQMD Rule 1168 . Provide current product certification documentation from certification body.
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver, store, and handle countertops and backsplash in a manner that will prevent damage and disfigurement.
Provide temporary skids under units.
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.1.1 Recycled Content for Countertop Materials
Recycled content is identified for some products in this section; provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT. Other products listed in this section may be available with recycled content; identify those products that meet project requirements for recycled content, and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT.
SECTION 12 36 00 Page 3
2.1.2 Reduce Volatile Organic Compounds (VOC) (LOW EMITTING MATERIALS) for Products
Reduced VOC content is identified for some products in this section;
provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph REDUCE VOLATILE ORGANIC COMPOUNDS (VOC) (LOW EMITTING MATERIALS). Other products listed in this section may be available with reduced VOC content; identify those products that meet project requirements for reduced VOC content, and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph REDUCE
VOLATILE ORGANIC COMPOUNDS (VOC) (LOW EMITTING MATERIALS).
2.2 SYSTEM DESCRIPTION
Provide the manufacturer's standard type countertops or as indicated on the drawings. Accomplish fastenings to permit removal and replacement of individual countertops without affecting the remainder of the installation.
Submit manufacturer's instructions for countertops including special provisions required to install equipment components and system packages.
Include all special notices detailing impedances, hazards and safety precautions.
Submit manufacturer's standard color charts for countertops showing the manufacturer's recommended color and finish selections.
Provide certification of indoor air quality for countertop products.
2.2.1 Design
Sheets cast from modified epoxy resin and non-asbestos inert fillers;
compounded mixture cured and thermoset specifically from formulation to provide exceptional physical and chemical resistance required in medium to heavy duty laboratory environments.
Physical properties; minimum acceptable physical performance in accordance with SEFA 3 testing procedures:
a. Density/specific gravity: Tested to ASTM D792; minimum test rating of
134.8 PSF or 2.16 gcm.
b. Rockwell hardness: Tested to ASTM D785; minimum M scale rating of 110.
c. Fire resistance: tested to ASTM D635; classified as self-extinguishing.
d. Surface burning characteristics: Tested to ASTM E84; flame spread index
7.4 and smoke develop index of 221.2.
e. Surface burning characteristics in vertical position: Tested to
ASTM D3801; maximum flame spread index of 7.4 and smoke developed index of 221.2.
f. Coefficient of linear thermal expansion: Tested to ASTM D696; rating of
2.46 x 10-5.
g. Heat deflection: Tested to ASTM D648; maximum 205 degrees F or 96 degrees C.
h. Flexural strength: Tested to ASTM D790; minimum rating 14.9 KPSI or 103 Mpa.
i. Flexural modulus: Tested to ASTM D790; 2,777,501 PSI or 19.2 Gpa.
j. Water absorption, 24 hours: tested to ASTM D570; maximum 0.008 percent by weight.
k. Compression strength: Tested to ASTM D695; minimum 38.4 kpsi or 265
Mpa.
SECTION 12 36 00 Page 4
l. Chemical resistance; minimum acceptable chemical resistance performance in accordance with SEFA 8:
Reagent Tested Method Rating
Amyl Acetone A 0 Ethyl Acetate A 1 Acetic Acid 98% B 0 Acetone A 1 Acid Dichromate 5% B 0 Butyl Alcohol A 0 Ethyl Alcohol A 0 Methyl Alcohol A 0 Ammonium Hydroxide, 28% B 0 Benzene A 1 Carbon Tetrachloride A 0 Chloroform A 1 Chromic Acid 60% B 0 Cresol A 0 Dichloro Acetic Acid A 0 Dimethylformanide A 0 Dioxane A 1 Ethyl Ether A 0 Formaldehyde 37% A 0 Formic Acid 90% B 1 Furfural A 0 Gasoline A 0 Hydrochloric Acid, 37% B 0 Hydroflouric Acid 48% B 3 Hydrogen Peroxide 28% B 0 Tincture of Iodine B 0 Methyl Ethyl Ketone A 1 Methylene Chloride A 1 Mono Chlorobenzene A 1 Napthalene A 0 Nitric Acid, 20% B 0 Nitric Acid, 30% B 0 Nitric Acid, 70% B 0 Phenol 90% A 0 Phosphoric Acid, 85% B 0 Silver Nitrate, Saturated B 0 Sodium Hydroxide, 10% B 0 Sodium Hydroxide, 20% B 1 Sodium Hydroxide, 40% B 1 Sodium Hydroxide, Flake B 0 Sodium Sulfide, Saturated B 0 Sulfuric Acid, 25% B 0 Sulfuric Acid, 85% B 1 Sulfuric Acid, 96% B 3 Sulfuric Acid 85%, and Nitric Acid 70%, equal parts B 1 Toluene A 0 Trichlorethylene A 1 Xylene A 0 Zinc Chloride, Saturated B 0
Testing Method Descriptions:
Method A - Volatile chemicals (organic solvents): Cotton ball saturated
SECTION 12 36 00 Page 5 with test reagent is placed in one-ounce bottle (20 x 75mm test tube or similar container) with reservoir of liquid above ball. Container is inverted on test material for period of 24 hours at standard temperature 23 degrees C plus or minus 2 degrees C (73 degrees F plus or minus 4 degrees F).
Method B - Non Volatile Chemicals: Five drops (1/4 cc) of test reagent are placed on test material surface. Reagent is then covered with watch glass (25 mm) for period of no less than 24 hours at standard temperature of 23 degrees C plus or minus 2 degrees C (73 degrees F plus or minus 4 degrees F).
Result Definitions:
0 - No Effect: No detectible change in material surface.
1 - Good: Slight detectable change in color or gloss but no change to function or life of work surface material.
2 - Fair: Slight surface etching or severer staining. Clearly discernable change in color or gloss but no significant impairment of surface life or function.
3 - Poor: Pitting, cratering or erosion of work surface material; obvious and significant deterioration. Objectionable change in appearance due to surface discoloration.
Color: To be selected from manufacturer’s standard color range.
2.3 ACCESSORIES
Installation Materials: Manufacturer's joint adhesive, panel adhesive, and sealants as required to suit project conditions.
2.4 FABRICATION
2.4.1 Countertop And Backsplash
Fabricated tops and accessories in accordance with manufacturer's recommendations, approved Shop Drawings, and SEFA 8.
Epoxy Resin Worksurfaces:
1. Thickness:
a. 1-1/4 inches (32 mm).
b. Check each sheet at factory for required thickness.
c. Maximum variation in thickness: plus or minus 1/16 inch (1.6 mm) from corner to corner.
2. Warpage:
a. Inspect tops for warpage prior to fabrication by placing on true flat surface.
b. Maximum allowable warpage: 1/16 inch (1.5 mm) in 36 inch (900 mm) span or 3/16 inch (4.5 mm) in 96 inch (2400 mm) span.
3. Fabrication:
a. Shop fabricate in longest practical lengths.
b. Bond joints with highly chemical resistant cement with properties and color similar to base material.
c. Provide 1/8 inch (3 mm) drip groove at underside of exposed edges, set back 1/2 inch (13 mm) from face.
SECTION 12 36 00 Page 6
d. Finish exposed edges.
4. Fabricate tops flat with 1/4 inch (6 mm) raised marine edge and flat with 1/4 inch (6 mm) raised marine edge at epoxy sink locations.
5. Edge treatment: Standard 1/8 inch (2 mm) chamfered edge with drip groove.
6. Corner treatment: exposed corners shall be eased slightly for safety.
7. Back and end splashes:
a. Supplied loose for field installation.
b. Same material and thickness as worksurfaces.
c. 4 inches (100 mm) high unless otherwise indicated.
d. Top-mounted end splash where worksurfaces abut adjacent construction at and locations indicated on Drawings.
8. Joints: Maximum 1/8 inch (2 mm), bonded with epoxy grout.
9. Make joints between two benches level.
10. Locate joints away from sinks and over or near supports.
11. Sink cutouts: As indicated on Drawings.
12. Allowable tolerances:
a. Square: Plus or minus 1/64 inch (0.4 mm) for each 12 inches (300
mm) of length.
b. Location of cutouts and drilled openings: Plus or minus 1/8 inch (3
mm) of design dimension.
c. Size of cutouts and drilled openings: Plus 1/8 inch (3 mm) or minus 0 inches (0 mm).
2.5 MIXES
2.5.1 Adhesives
Provide certification of indoor air quality for adhesives.
2.5.1.1 Mounting Adhesives
Provide structural-grade silicone or epoxy adhesives of type recommended by manufacturer for application and conditions of use.
Provide spacers, if required, of type recommended by adhesive manufacturer.
2.5.2 Joint Sealants
Use clear silicone sealant of type recommended by manufacturer for application and conditions of use. Provide certification of indoor air quality for joint sealants.
PART 3 EXECUTION
3.1 INSTALLATION
Inspect material for defects prior to installation. Ensure materials throughout bear labels with the same batch number. Visually inspect materials used for adjacent pieces to assure acceptable color match.
Inspect in lighting conditions similar to those on the project. Repair or replace damaged materials.
SECTION 12 36 00 Page 7
Install countertops plumb with cabinetry level to within 1 millimeter in 3000 millimeter. Level base cabinets by adjusting leveling screws.
Scribe and fit scribe strips to irregularities of adjacent surfaces. Gap openings exceeding 0.63 millimeter are not acceptable.
Secure countertops to cabinetry and wall construction using 6 millimeter diameter masonry anchors, spaced 760 millimeter maximum on center.
Submit installation drawings for countertops. Ensure drawings include location of cabinets, details of cabinets related and dimensional positions, and locations for roughing in plumbing, including sinks, faucets, strainers and cocks.
3.1.1 Preliminary Installation and Adjustment
Install materials in accordance to manufacturer's recommendations. Lift and place to avoid breakage.
Position materials to verify that materials are correctly sized and prepared. Make necessary adjustments.
If jobsite cutting, grinding, or polishing is required, use water-cooled tools. Protect jobsite and surfaces against dust and water. Perform work away from installation site if possible.
Shim countertop drainage adjacent to sinks and where drainage is required, slightly to insure positive drainage.
3.1.2 Permanent Installation
After verifying fit, remove epoxy resin surfacing from position, clean substrates of dust and contamination, and clean epoxy resin surfacing back side and joints with solvent.
Apply sufficient quantity of mounting adhesive in accordance with adhesive manufacturer's recommendations to provide permanent, secure installation.
Fasteners
Install surfacing plumb, level, and square and flat to within 1.6 mm in 3 meters.
3.1.3 Joints
Ensure joints between adjacent pieces of quartz surfacing are:
a. Flush, tight fitting, level, and neat.
b. Securely joined with stone adhesive. Fill joints level with countertop surfacing.
Clamp or brace countertop surfacing in position until adhesive sets.
Seal joints between backsplashes and countertops with silicone sealer.
3.2 FIELD QUALITY CONTROL
Examine casework grounds and supports for adequate anchorage, foreign
SECTION 12 36 00 Page 8 material, moisture, and unevenness that could prevent quality casework installation.
Ensure that electrical and plumbing rough-ins for casework are complete.
Do not proceed with installation until defects are corrected.
3.3 ADJUSTING AND CLEANING
3.3.1 Solvent
Use a product recommended by adhesive manufacturer to clean surface of countertop surfacing to assure adhesion of adhesives and sealants.
3.3.2 Cleaning Agents
Use non-abrasive, soft-scrub type kitchen cleaners.
3.3.3 Cleaning
On completion of cabinet installation, touch up marred or abraded finished surfaces. Remove crating and packing materials from premises. Wipe down surfaces to remove fingerprints and markings and leave in clean condition.
SECTION 12 36 00 Page 9
THIS PAGE INTENTIONALLY LEFT BLANK
SECTION 12 36 00 Page 10
SECTION 12 48 13
ENTRANCE FLOOR MATS AND FRAMES
08/17
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AENOR - UNA NORMA ESPAÑOLA (UNE)
UNE-EN 755-1 (2016) Aluminium and aluminium alloys - Extruded rod/bar, tube and profiles - Part 1: Technical conditions for inspection and delivery
ASTM INTERNATIONAL (ASTM)
ASTM B221M (2013) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
ASTM D2047 (2011) Static Coefficient of Friction of Polish-Coated Floor Surfaces as Measured by the James Machine
ASTM E648 (2017a) Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUSTAINABILITY REPORTING
Materials in this technical specification may increase contract compliance with sustainability requirements.
1.2.1 EPA Comprehensive Procurement Guidelines
See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with EPA-designated products.
1.2.2 USDA Biobased
See Section 01 33 29 SUSTAINABILITY REPORTING for requirements associated with USDA Biobased products.
SECTION 12 48 13 Page 1
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Installation Drawings; G
Detail Drawings; G
SD-03 Product Data
Entrance Floor Mats and Frames; G
Adhesives and Concrete Primers; G
SD-08 Manufacturer's Instructions
Manufacturer's Instructions
SD-10 Operation and Maintenance Data
Protection, Maintenance, and Repair Information
1.4 QUALITY CONTROL
Comply with 36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines for installed entrance floor mats and frames. Ensure that entrance floor mats and frames are slip-resistant in accordance with ASTM D2047, with a minimum 0.60 coefficient of friction, for accessible routes and are structurally capable of withstanding a rolling load of 1000 lbs/454 kg. Ensure that flammability is in accordance with ASTM E648, Class 1, Critical Radiant Flux, minimum 0.45 watts/square meter.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the project site in their original packages or containers bearing labels clearly identifying the manufacturer, brand name, and quality or grade.
Store materials in their original unbroken packages or containers in the area in which they will be installed. Unwrap, inspect, and place mats at indicated locations. Remove all excess packing materials.
PART 2 PRODUCTS
2.1 MANUFACTURED UNITS
2.1.1 Entrance Floor Mats and Frames
Submit the manufacturer's catalog data. Submit samples of assembled sections of floor mats showing corners, intersections, and other details
SECTION 12 48 13 Page 2 of construction. Submit samples of exposed floor mats, frame finishes and accessories.
2.1.1.1 Floor Grids
Provide a floor grid consisting of a series of aluminum tread rails spaced 38 mm on…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .