ATT J 1561956dwg02of19.pdf
PDF 2 MB Posted
- Solicitation number
- N6247020R4011
About this file
This document package includes hazardous materials plans and notes for buildings at Naval Station Rota, Spain. The plans identify locations of asbestos-containing materials including pipe insulation, floor tiles, and tar/silver coating. Notes specify the removal of these materials according to EPA regulations. Other hazardous materials like lead paint and fluorescent light tubes containing mercury are also addressed. The solicitation seeks proposals for an Indefinite Delivery Indefinite Quantity Multiple Award Construction Contract for projects primarily at Rota, Spain and worldwide. Offerors should plan to remove 1600 linear feet of pipe insulation, 70 square feet of floor tiles and mastic, and 500 square feet of tar/silver coating for bidding purposes. Proposals are due in response to solicitation number N6247020R4011 issued by the Naval Facilities Engineering Command, Department of the Navy. Awards will be made to multiple awardees under this IDIQ contract vehicle for construction projects over the next five years.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P -8
P
O R
T O
P E
R A
TI
O
N S
F A
C
IL
IT
IE
S
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
4525 Main Street, Suite 1400
Virginia Beach, VA 23462
757.455.5800
HAZARDOUS MATERIALS NOTES
NOTAS DE MATERIALES PELIGROSOS
H-001
PHOTOGRAPH DESCRIPTIONS
A1
A2
A3
KEY TO SYMBOLS
PHOTOGRAPHA1 PHOTOGRAPHA2 PHOTOGRAPHA3
PHOTOGRAPHB1 PHOTOGRAPHB2
DESCRIPCIÓN DE FOTOGRAFÍAS
B1
B2
CLAVE DE SÍMBOLOS
/ FOTOGRAFÍA / FOTOGRAFÍA
/ FOTOGRAFÍA / FOTOGRAFÍA / FOTOGRAFÍA
HUGH N. ADCOCK, JR.
Lic. No. 015231
12/13/19
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
NAVAL STATION
AutoCAD SHX Text
ROTA, SPAIN
AutoCAD SHX Text 1561956
AutoCAD SHX Text
AutoCAD SHX Text
SMS/LKJ
AutoCAD SHX Text
NAVFAC ATLANTIC
AutoCAD SHX Text
NORFOLK, VA
AutoCAD SHX Text
CYNTHIA DE JONG, RA
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
DESIGN DIRECTOR
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
HNA
AutoCAD SHX Text
BTH
AutoCAD SHX Text
HNA
AutoCAD SHX Text
AS INDICATED
AutoCAD SHX Text
AutoCAD SHX Text 14069885
AutoCAD SHX Text
NOTAS GENERALES
AutoCAD SHX Text
1. A HAZARDOUS MATERIALS INSPECTION WAS PERFORMED. THE SURVEY/INSPECTION REPORT IS PROVIDED IN THE SPECIFICATIONS. THE WORK WILL REQUIRE THE REMOVAL OF KNOWN ASBESTOS-CONTAINING MATERIALS (ACM). DESTRUCTIVE ACTIVITIES SUCH AS BREAKING INTO WALLS, CEILINGS AND FLOORS WERE NOT PERFORMED IN ORDER TO LOCATE MATERIALS. THEREFORE, IF DURING THE WORK SUSPECT MATERIALS ARE UNCOVERED, NOTIFY THE CONTRACTING OFFICER AND STOP WORK UNTIL THE MATERIAL IS PROPERLY IDENTIFIED AND ADDRESSED.
AutoCAD SHX Text
TYPICAL VIEW OF BUILDING 189.
AutoCAD SHX Text
TYPICAL VIEW OF ACM PIPE INSULATION FOUND THROUGHOUT BUILDING 189.
AutoCAD SHX Text
TYPICAL VIEW OF ACM FLOOR TILE IN THE THIRD FLOOR SERVER ROOM IN BUILDING 189.
AutoCAD SHX Text X
AutoCAD SHX Text
XXX
AutoCAD SHX Text
PHOTO LOCATION
AutoCAD SHX Text
(SHEET HM101 - HM103)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
HM101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
HM101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
HM101
AutoCAD SHX Text
UBICACIÓN DE FOTO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
HM101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
HM101
AutoCAD SHX Text
7. TOXICITY CHARACTERISTIC LEACHING PROCEDURE (TCLP) TESTING ON EXISTING PAINTED BUILDING MATERIALS, WHEN DEMOLISHED AS COMPONENTS OF AN ASSEMBLY TYPICALLY RETURN RESULTS CLASSIFYING THE WASTE AS NONHAZARDOUS. PAINTED MATERIAL REMOVED IN THE FORM OF STRIPPING, BLASTING, SCRAPING OR OTHER METHODS THAT REMOVE THE PAINT COATING FROM THE EXISTING SUBSTRATE, OR PRODUCES A WASTE RESULTING PRIMARILY OF PAINT MATERIAL, MAY RESULT IN WASTE CLASSIFIED AS HAZARDOUS. THE CONTRACTOR MUST COORDINATE THE WORK PROCEDURES TO CHARACTERIZE THE ANTICIPATED WASTE STREAM. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH CHARACTERIZATION AND DISPOSAL OF WASTE GENERATED FROM THE WORK. INCLUDE LEAD PAINT ABATEMENT EFFORTS FOR ALL WORK ITEMS AS NEEDED FOR THE PROJECT. COORDINATE WASTE DISPOSAL AND ACCUMULATION WITH NAVFAC EV PRIOR TO WASTE GENERATION ACTIVITIES.
AutoCAD SHX Text SE HA REALIZADO UNA INSPECCIÓN DE MATERIALES PELIGROSOS. EL INFORME DE ESA INSPECCIÓN ESTÁ INCLUIDO EN LAS ESPECIFICACIONES. LOS TRABAJOS REQUERIRÁN LA RETIRADA DE MATERIALES QUE SE CONOZCAN QUE CONTIENE AMIANTO. NO SE REALIZARÁN DEMOLICIONES DE PAREDES, TECHOS O SUELOS PARA DESCUBRIR O IDENTIFICAR MATERIALES CON CONTENIDO DE AMIANTO. POR LO TANTO, SI DURANTE LAS DEMOLICIONES SE DESCUBREN MATERIALES SOSPECHOSOS DE CONTENER AMIANTO, SE NOTIFICARÁ AL OFICIAL CONTRATANTE Y SE DETENDRÁN LOS TRABAJOS HASTA QUE ESOS MATERIALES SEAN IDENTIFICADOS DE FORMA ADECUADA Y LAS ACCIONES A REALIZAR IDENTIFICADAS.
AutoCAD SHX Text
2. THE CONTRACT DOCUMENTS REPRESENT CONDITIONS WITHIN THE FACILITY AT THE TIME OF THE INITIAL FIELD INVESTIGATION. REFER TO REPORT TO DETERMINE THOSE CONDITIONS. SHOULD CONDITIONS EXISTS OTHER THAN THOSE INDICATED IN THE REPORT, CONSULT THE ON-SITE PRIVATE QUALIFIED PERSON AND THE DESIGNER OF RECORD FOR VERIFICATION.
AutoCAD SHX Text LOS DOCUMENTOS CONTRACTUALES REPRESENTAN LAS CONDICIONES DENTRO DEL EDIFICIO EN EL MOMENTO DE LA INSPECCIÓN. VER EL INFORME PARA DETERMINAR ESAS CONDICIONES. SI EXISTIERAN CONDICIONES DISTINTAS A LAS INDICADAS, CONSULTAR CON LA PERSONA CUALIFICADA EN OBRA Y CON EL DISEÑADOR DE REFERENCIA PARA VERIFICAR ESTOS EXTREMOS.
AutoCAD SHX Text
3. CONTRACTOR MUST VISIT THE SITE TO ASCERTAIN THE EXACT NATURE AND LOCATION OF THE WORK INCLUDING THE WORK OR COST THEREOF.
AutoCAD SHX Text EL CONTRATISTA DEBERÁ VISITAR LA ZONA DE OBRAS PARA CONOCER EL ALCANCE DE LOS TRABAJOS Y SU COSTE.
AutoCAD SHX Text
4. CONTRACTOR MUST COORDINATE ALL ASPECTS OF THE WORK WITH OTHER TRADES. SEE ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DEMOLITION DRAWINGS.
AutoCAD SHX Text GESTIONAR TODOS LOS DESHECHOS DE ACUERDO CON TODAS LAS REGULACIONES LOCALES, NACIONALES Y REGIONALES, INCLUIDO 40 CFR 261 Y 40 CFR 262. CUMPLIR CON LOS REQUERIMIENTOS DE LA INSTALACIÓN Y NAVFAC.
AutoCAD SHX Text
5. REMOVE ACM IN ACCORDANCE WITH SPECIFICATION SECTION 02 82 00 "ASBESTOS REMEDIATION." FOR BIDDING PURPOSES THE FOLLOWING ACM WILL BE REMOVED: (A) PIPE INSULATION, 1,600 LF, (B) FLOOR TILE AND MASTIC, 70 SF, AND (C) TAR/SILVER COATING ON CORRUGATED METAL 500 SF.
AutoCAD SHX Text RETIRAR MATERIALES CON AMIANTO DE ACUERDO CON LA ESPECIFICACIÓN 02 82 00 "ASBESTOS REMEDIATION". A EFECTOS DE OFERTA, CONSIDERAR QUE SE TENDRÁN QUE RETIRAR: (A) 1500 PIES DE AISLAMIENTO DE TUBERÍAS (B) 70 PIES CUADRADOS DE SOLERÍA CON AMIANTO, Y (C) 500 PIES CUADRADOS DE ASFALTO CON AMIANTO Y RECUBRIMIENTO CON ACABADO CORRUGADO METÁLICO.
AutoCAD SHX Text
6. EXISTING PAINT WITHIN THE STRUCTURE HAS BEEN DETERMINED TO CONTAIN CONCENTRATIONS ABOVE THE LABORATORY'S MINIMUM DETECTION LIMIT OF THE FOLLOWING METALS: LEAD, CADMIUM AND CHROMIUM. PERFORM RENOVATION WORK IN ACCORDANCE WITH SPECIFICATION SECTION 02 83 00 "LEAD REMEDIATION". CONSTRUCTION STANDARDS ESTABLISHED BY OSHA FOR CHROMIUM, CADMIUM AND LEAD ARE; CHROMIUM, 29 CFR 1926.1126; CADMIUM, 29 CFR 1926.1127 AND LEAD, 29 CFR 1926.62
AutoCAD SHX Text SE HAN HALLADO PINTURAS EN LA ESTRUCTURA CON CONTENIDO DE PLOMO, CADMIO Y CROMO, POR ENCIMA DE LOS LÍMITES MÍNIMOS QUE SON DETECTABLES EN LABORATORIO. REALIZAR LOS TRABAJOS DE RENOVACIÓN DE ACUERDO CON LA ESPECIFICACIÓN 02 83 00 "LEAD REMEDIATION". LOS ESTÁNDARES DE CONSTRUCCIÓN ESTABLECIDOS POR OSHA PARA CROMO, CADMIO Y PLOMO SON: 29 CFR 1926.1126, 29CFR 1926.1127 AND 29 CFR 1926.62.
AutoCAD SHX Text EL ENSAYO DE PROCEDIMIENTO PARA DETERMINAR LA TOXICIDAD EN MATERIALES DE PAREDES PINTADAS (TCLP) CUANDO SE DEMUELAN LOS COMPONENTES DEL ENSAMBLAJE DAN RESULTADOS TÍPICOS COMO NO-PELIGROSOS. POR OTRA PARTE, LA RETIRADA DE PINTURA MEDIANTE RASPADO, RASCADO O MEDIOS MECÁNICOS QUE RESULTAN EN RESIDUOS PRIMA- RIAMENTE DE PINTURA SI PUEDEN RESULTAR EN RESIDUOS PELIGROSOS. EL CONTRATISTA DEBERÁ COORDINAR LOS PROCEDIMIENTOS DE LOS TRABAJOS PARA CARACTERIZAR LOS RESIDUOS QUE SE PUEDAN GENERAR EN LOS TRABAJOS DE RETIRADA Y DEMOLICIÓN. EL CONTRATISTA SERÁ RESPONSABLE DE TODOS LOS COSTOS ASOCIADOS CON LA CARACTERIZACIÓN Y RETIRADA A VERTEDERO DE LOS RESIDUOS GENERADOS EN LAS DEMOLICIONES. INCLUIR LA RETIRADA DE PINTURA CON PLOMO EN TODOS LOS ASPECTOS REQUERIDOS EN EL PROYECTO. COORDINAR LA RETIRADA DE RESIDUOS CON NAVFAC EV ANTES DE EMPEZAR ACTIVIDADES QUE GENERAN ESTE TIPO DE RESIDUOS.
AutoCAD SHX Text
8. ALL LIGHT BALLASTS WITHOUT "NON PCB" MARKINGS AND ALL FLUORESCENT LIGHT TUBES MUST BE REMOVED IN ACCORDANCE WITH SPECIFICATION SECTION 02 84 16. FOR BIDDING PURPOSES, ASSUME 5 BALLASTS CONTAIN PCB's AND 200 FLUORESCENT LIGHT TUBES CONTAIN MERCURY VAPOR. COORDINATE WASTE DISPOSAL AND ACCUMULATION WITH NAVFAC EV PRIOR TO WASTE GENERATION ACTIVITIES.
AutoCAD SHX Text TODOS LOS BALASTOS Y REACTANCIAS SIN MARCADO "NON PCB" Y TODAS LAS LUMINARIAS FLUORESCENTES SE RETIRARÁN DE ACUERDO CON LA ESPECIFICACIÓN 02 84 16. A EFECTOS DE OFERTA, ASUMIR QUE 5 BALASTOS CONTIENEN PCB's Y QUE 200 LUMINARIAS FLUORESCENTES CONTIENEN VAPOR DE MERCURIO. COORDINAR LA RETIRADA Y ACUMULACIÓN DE RESIDUOS DE ACUERDO CON NAVFAC ANTES DE EMPEZAR LA RETIRADA DE ESTOS MATERIALES.
AutoCAD SHX Text
9. DISASSEMBLE, REMOVE, AND INSPECT ALL DOORS TO DETERMINE ASBESTOS CONTENT. REMOVE, HANDLE, AND DISPOSE OF ASBESTOS FIRE DOORS IN ACCORDANCE WITH SPECIFICATION SECTION 02 82 00. NON-ASBESTOS FIRE DOORS MUST BE DISPOSED OF AS REGULAR CONSTRUCTION WASTE. FOR BIDDING PURPOSES, ASSUME 10 ASBESTOS-CONTAINING FIRE DOORS EXIST (TOTAL FOR PROJECT).
AutoCAD SHX Text DESMONTAR, RETIRAR E INSPECCIONAR TODAS LAS PUERTAS PARA DETERMINAR CONTENIDO DE AMIANTO. RETIRAR, GESTIONAR Y LLEVAR A VERTEDERO LOS RESTOS DE AMIANTO DE LAS PUERTAS RESISTENTES A FUEGO DE ACUERDO CON LA ESPECIFICACIÓN 02 82 00. LAS PUERTAS CORTAFUEGO SIN CONTENIDO DE AMIANTO PUEDEN LLEVARSE DIRECTAMENTE A VERTEDERO COMO OTROS ESCOMBROS. A EFECTOS DE OFERTA, ASUMIR QUE HAY 10 PUERTAS CON CONTENIDO DE AMIANTO.
AutoCAD SHX Text
10. MANAGE ALL WASTE IN ACCORDANCE WITH ALL LOCAL, STATE AND REGIONAL REGULATIONS INCLUDING 40 CFR 261 AND 40 CFR 262. COMPLY WITH ALL INSTALLATION AND NAVFAC EV REQUIREMENTS.
AutoCAD SHX Text EL CONTRATISTA DEBERÁ COORDINAR LOS TRABAJOS CON OTRAS DISCIPLINAS. VER PLANOS DE DEMOLICIONES DE ARQUITECTURA, FONTANERÍA Y SANEAMIENTO, MECÁNICA Y ELECTRICIDAD.
AutoCAD SHX Text
TYPICAL VIEW OF BUILDING 215.
AutoCAD SHX Text TYPICAL VIEW OF ACM TAR/SILVER COATING FOUND UNDER THE POLYURETHANE FOAM NEAR THE ROLL-UP DOOR ON THE SOUTH END OF BUILDING 215.
AutoCAD SHX Text
VISTA TÍPICA DE EDIFICIO 189.
AutoCAD SHX Text
VISTA TÍPICA DE AISLAMIENTO CON AMIANTO ENCONTRADO A LO LARGO DEL EDIFICIO 189.
AutoCAD SHX Text VISTA TÍPICA DE LOSETAS DE SUELO CON AMIANTO EN EL CUARTO DEL SERVIDOR, TERCERA PLANTA DE EDIFICIO 189.
AutoCAD SHX Text VISTA TÍPICA DE ASFALTO CON AMIANTO Y RECUBRIMIENTO DE PLATA QUE SE ENCUENTRA BAJO LA CAPA DE ESPUMA DE POLIURETANO CERCA DE LA PUERTA ENROLLABLE EN EL EXTREMO SUR DEL EDIFICIO 215.
AutoCAD SHX Text
(PLANOS HM101 - HM103)
AutoCAD SHX Text
/ SIN ESCALA
AutoCAD SHX Text
HM101
AutoCAD SHX Text
/ SIN ESCALA
AutoCAD SHX Text
HM101
AutoCAD SHX Text
/ SIN ESCALA
AutoCAD SHX Text
HM101
AutoCAD SHX Text
/ SIN ESCALA
AutoCAD SHX Text
HM101
AutoCAD SHX Text
/ SIN ESCALA
AutoCAD SHX Text
HM101
AutoCAD SHX Text
VISTA TÍPICA DE EDIFICIO 215.
BUILDING 189 - FIRST FLOOR HAZARDOUS MATERIALS PLAN
/ ESCALA GRAFICAGRAPHIC SCALE
BUILDING 189 - SECOND FLOOR HAZARDOUS MATERIALS PLAN
ROOM LEGEND
P -8
P
O R
T O
P E
R A
TI
O
N S
F A
C
IL
IT
IE
S
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
4525 Main Street, Suite 1400
Virginia Beach, VA 23462
757.455.5800
EDIFICIO 189 - PLANTA DE MATERIALES PELIGROSOS- PRIMERA PLANTA
EDIFICIO 189 - PLANTA DE MATERIALES PELIGROSOS- SEGUNDA PLANTA
/ LEYENDA DE HABITACIONES
GENERAL NOTES
HAZARDOUS MATERIALS KEYNOTES
LEGEND/ LEYENDA
/ NOTAS GENERALES
NOTAS DE REF. DE MATERIALES PELIGROSOS
HM101
A1
C1
HUGH N. ADCOCK, JR.
Lic. No. 015231
12/13/19
AutoCAD SHX Text
FACP
AutoCAD SHX Text
TX
AutoCAD SHX Text
AutoCAD SHX Text 103A
AutoCAD SHX Text 103B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 101D
AutoCAD SHX Text 101B
AutoCAD SHX Text 101C
AutoCAD SHX Text 101A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 204A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
AutoCAD SHX Text 1:50
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5m
AutoCAD SHX Text 0.5
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text 101A
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 101B
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 101C
AutoCAD SHX Text 103A
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 101D
AutoCAD SHX Text 103B
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
WORK ROOM
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
AutoCAD SHX Text 204A
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
NAVAL STATION
AutoCAD SHX Text
ROTA, SPAIN
AutoCAD SHX Text 1561956
AutoCAD SHX Text
AutoCAD SHX Text
SMS/LKJ
AutoCAD SHX Text
NAVFAC ATLANTIC
AutoCAD SHX Text
NORFOLK, VA
AutoCAD SHX Text
CYNTHIA DE JONG, RA
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
DESIGN DIRECTOR
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
BUILDING 189 - HAZARDOUS MATERIALS PLANS
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
VESTÍBULO
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
TAQUILLAS
AutoCAD SHX Text
CUARTO DE BAÑO
AutoCAD SHX Text
SALA DE TRABAJO
AutoCAD SHX Text
CUARTO MECÁNICO
AutoCAD SHX Text
VESTÍBULO
AutoCAD SHX Text
SALA DE CONFERENCIAS
AutoCAD SHX Text
TAQUILLAS
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
PASILLO
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
CUARTO DE BAÑO
AutoCAD SHX Text
HNA
AutoCAD SHX Text
HNA
AutoCAD SHX Text
BTH
AutoCAD SHX Text
AS INDICATED
AutoCAD SHX Text
AutoCAD SHX Text 14069886
AutoCAD SHX Text
EDIFICIO 189 - PLANTAS DE MATERIALES PELIGROSOS
AutoCAD SHX Text
1. COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED FOR ADDITIONAL DEMOLITION INFORMATION.
AutoCAD SHX Text
XX
AutoCAD SHX Text COORDINAR LOS TRABAJOS CON LOS PLANOS DE OTRAS DISCIPLINAS INCLUIDAS COMO INFORMACIÓN ADICIONAL PARA LAS DEMOLICIONES.
AutoCAD SHX Text
REMOVE ACM PIPE INSULATION.
AutoCAD SHX Text
AutoCAD SHX Text
RETIRAR AISLAMIENTO DE TUBERÍAS CON AMIANTO.
AutoCAD SHX Text A1
AutoCAD SHX Text H-001
AutoCAD SHX Text A2
H-001
BUILDING 189 - THIRD FLOOR HAZARDOUS MATERIALS PLAN
BUILDING 515 - HAZARDOUS MATERIALS PLAN
/ ESCALA GRAFICAGRAPHIC SCALE
/ LEYENDA DE HABITACIONESROOM LEGEND
P -8
P
O R
T O
P E
R A
TI
O
N S
F A
C
IL
IT
IE
S
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
4525 Main Street, Suite 1400
Virginia Beach, VA 23462
757.455.5800
EDIFICIO 515 - PLANTA DE MATERIALES PELIGROSOS
GENERAL NOTES
LEGEND/ LEYENDA
/ NOTAS GENERALES
BUILDING 1976 - HAZARDOUS MATERIALS PLAN
HM102
C1 C3
A1
HAZARDOUS MATERIALS KEYNOTESEDIFICIO 1976 - PLANTA DE MATERIALES PELIGROSOS
EDIFICIO 189 - PLANTA DE MATERIALES PELIGROSOS - TERCERA PLANTA
NOTAS DE REF. DE MATERIALES PELIGROSOS
HUGH N. ADCOCK, JR.
Lic. No. 015231
12/13/19
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 308A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
AutoCAD SHX Text 1:50
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5m
AutoCAD SHX Text 0.5
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
OPERATIONS ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 308A
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
NAVAL STATION
AutoCAD SHX Text
ROTA, SPAIN
AutoCAD SHX Text 1561956
AutoCAD SHX Text
AutoCAD SHX Text
SMS/LKJ
AutoCAD SHX Text
NAVFAC ATLANTIC
AutoCAD SHX Text
NORFOLK, VA
AutoCAD SHX Text
CYNTHIA DE JONG, RA
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
DESIGN DIRECTOR
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
BUILDINGS 189, 515 & 1976 - HAZARDOUS MATERIALS PLANS
AutoCAD SHX Text
VESTÍBULO
AutoCAD SHX Text
CUARTO DE TELECOMUNICACIONES
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
CUARTO DE OPERACIONES
AutoCAD SHX Text
CUARTO DE BAÑO
AutoCAD SHX Text
PASILLO
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
HNA
AutoCAD SHX Text
HNA
AutoCAD SHX Text
BTH
AutoCAD SHX Text
AS INDICATED
AutoCAD SHX Text
AutoCAD SHX Text 14069887
AutoCAD SHX Text
EDIFICIOS 189, 515 & 1976 - PLANTAS DE MATERIALES PELIGROSOS
AutoCAD SHX Text
1. COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED FOR ADDITIONAL DEMOLITION INFORMATION.
AutoCAD SHX Text
XX
AutoCAD SHX Text
REMOVE ACM PIPE INSULATION.
AutoCAD SHX Text
REMOVE ACM FLOOR TILE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XX
AutoCAD SHX Text A3
AutoCAD SHX Text H-001
AutoCAD SHX Text COORDINAR LOS TRABAJOS CON LOS PLANOS DE OTRAS DISCIPLINAS INCLUIDAS COMO INFORMACIÓN ADICIONAL PARA LAS DEMOLICIONES.
AutoCAD SHX Text
RETIRAR AISLAMIENTO DE TUBERÍAS CON AMIANTO.
RETIRAR LOSAS DE SOLERÍA CON AMIANTO.
BUILDING 215 - HAZARDOUS MATERIALS PLAN
/ ESCALA GRAFICAGRAPHIC SCALE
/ LEYENDA DE HABITACIONESROOM LEGEND
P -8
P
O R
T O
P E
R A
TI
O
N S
F A
C
IL
IT
IE
S
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
4525 Main Street, Suite 1400
Virginia Beach, VA 23462
757.455.5800
EDIFICIO 215 - PLANTA DE MATERIALES PELIGROSOS
GENERAL NOTES LEGEND/ LEYENDA/ NOTAS GENERALES / NOTAS DE REF. DE MATERIALES PELIGROSOS
HM103
B1
HAZARDOUS MATERIALS KEYNOTES
HUGH N. ADCOCK, JR.
Lic. No. 015231
12/13/19
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1:50
AutoCAD SHX Text
AutoCAD SHX Text 1:50
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5m
AutoCAD SHX Text 0.5
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NAME
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
/ NOMBRE
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
TOOL ROOM
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
UNCLASSIFIED
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
OF
AutoCAD SHX Text
EPROJECT NO.:
AutoCAD SHX Text
NAVAL STATION
AutoCAD SHX Text
ROTA, SPAIN
AutoCAD SHX Text 1561956
AutoCAD SHX Text
AutoCAD SHX Text
SMS/LKJ
AutoCAD SHX Text
NAVFAC ATLANTIC
AutoCAD SHX Text
NORFOLK, VA
AutoCAD SHX Text
CYNTHIA DE JONG, RA
AutoCAD SHX Text
PM/DM
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
DESIGN DIRECTOR
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
BUILDING 215 - HAZARDOUS MATERIALS PLAN
AutoCAD SHX Text
ALMACÉN
AutoCAD SHX Text
OFICINA
AutoCAD SHX Text
CUARTO ELÉCTRICO
AutoCAD SHX Text
ALMACÉN
AutoCAD SHX Text
CUARTO DE HERRAMIENTAS
AutoCAD SHX Text
ALMACÉN
AutoCAD SHX Text
ALMACÉN
AutoCAD SHX Text
ALMACÉN
AutoCAD SHX Text
ESCALA
AutoCAD SHX Text
HNA
AutoCAD SHX Text
HNA
AutoCAD SHX Text
BTH
AutoCAD SHX Text
AS INDICATED
AutoCAD SHX Text
AutoCAD SHX Text 14069888
AutoCAD SHX Text
EDIFICIO 215 - PLANTAS DE MATERIALES PELIGROSOS
AutoCAD SHX Text
1. COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED COORDINATE WORK WITH OTHER DISCIPLINE DRAWINGS INCLUDED FOR ADDITIONAL DEMOLITION INFORMATION.
AutoCAD SHX Text
XX
AutoCAD SHX Text
REMOVE ACM TAR AND SILVER COATING.
AutoCAD SHX Text
AutoCAD SHX Text
RETIRAR ASFALTO CON AMIANTO Y RECUBRIMIENTO DE PLATA.
AutoCAD SHX Text
XX
AutoCAD SHX Text B1
AutoCAD SHX Text H-001
AutoCAD SHX Text B2
AutoCAD SHX Text H-001
COORDINAR LOS TRABAJOS CON LOS PLANOS DE OTRAS DISCIPLINAS INCLUIDAS COMO INFORMACIÓN ADICIONAL PARA LAS DEMOLICIONES.
| Sheets and Views |
| H001-H-101 |
| HM101-HM101 |
| HM102-HM102 |
| HM103-HM103 |
| 2019-12-13T10:00:22-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:00:33-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:00:34-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:00:34-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:01:18-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:01:29-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:01:29-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
| 2019-12-13T10:01:30-0500 | |
| Virginia Beach | |
| Hugh N. Adcock, JR. | |
| I, Hugh N. Adcock, JR., am signing to approve this document. |
2020-03-24T09:46:18-0400
2020-03-24T09:47:31-0400
2020-03-24T09:48:17-0400
2020-03-24T09:49:02-0400
2020-03-25T08:07:33-0400
2020-03-25T08:07:46-0400
2020-03-25T08:08:08-0400
2020-03-25T08:08:22-0400
2020-03-26T16:19:42-0400
2020-03-26T16:20:20-0400
2020-03-26T16:20:22-0400
2020-03-26T16:20:24-0400
| 2020-03-27T06:45:09-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
| 2020-03-27T06:45:32-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
| 2020-03-27T06:45:33-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
| 2020-03-27T06:45:34-0400 | |
| Rick Stephens | |
| I, Rick Stephens, am signing to approve this document. |
File details come from the government source that posted it. Updated .