This document package provides inventory attachments for a facilities maintenance and operations services contract solicitation. The solicitation seeks base operations support services at Marine Corps Base Quantico in Virginia. Services include maintenance and repair of real property, utilities systems, equipment and other assets. Inventories are provided for over 40 categories of facilities equipment and systems across multiple activities and commands. Items include HVAC, electrical, fire protection, vertical transportation, security and other built infrastructure. The document package contains detailed asset listings to inform maintenance requirements for offerors.
J_1502000_Facility_Investment_Revised_Amd_0001.pdf
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION J
DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
TABLE OF CONTENTS
ATTACHMENT
NUMBER
ATTACHMENT TITLE
J-1502000-01 Definitions and Acronyms J-1502000-02 References and Technical Documents J-1502000-03 Facility Inventory J-1502000-04 Historical Service Order Workload J-1502000-05 Historical Project Work Order Workload J-1502000-06 Temperature Standards J-1502000-07 HVAC and Refrigeration Systems Equipment Inventory J-1502000-08 Interior and Exterior Lighting Systems Inventory J-1502000-09 Boilers and Unfired Pressure Vessels (UPVs) Equipment Inventory J-1502000-10 Cathodic Protection Systems Inventory J-1502000-11 Lightning Arrestors and Grounding Device Inventory J-1502000-12 Fire Protection Systems Inventory J-1502000-13 Auxiliary Generators Inventory J-1502000-14 Uninterrupted Power Systems (UPS) Inventory J-1502000-15 Vehicle Barrier and Gate System Inventory J-1502000-16 Weapons Bluing Equipment Inventory J-1502000-17 Emergency and Exit Lighting Systems Inventory J-1502000-18 Vertical Transportation Equipment Inventory J-1502000-19 Airfield Lighting System Inventory J-1502000-20 Roll-Up, Overhead and Automated Doors Inventory J-1502000-21 Emergency Eyewash and Shower Station Inventory J-1502000-22 Lifts and Mobile Scaffolds Inventory J-1502000-23 Rainwater Harvesting Systems Inventory J-1502000-24 Building Control Systems Inventory J-1502000-25 Facility Electrical Systems Inventory J-1502000-26 Pumps Inventory J-1502000-27 Ornamental Fountains Inventory J-1502000-28 Plant Systems Equipment Inventory J-1502000-29 Backflow Prevention Devices Inventory
J-1502000-30 RESERVED
J-1502000-31 Fall Protection Systems Inventory J-1502000-32 Grease Traps Inventory J-1502000-33 Exhaust Hoods and Duct Inventory J-1502000-34 HVAC Water Testing and Treatment Services Inventory J-1502000-35 Boiler Water Testing and Treatment Services Inventory J-1502000-36 Oil Water Separator Inventory J-1502000-37 Drinking Fountains Inventory J-1502000-38 Building Drainage System Inventory J-1502000-39 Solar Panels Inventory J-1502000-40 Compressed Natural Gas System Inventory
J-1502000-40.a Inspection Checklist J-1502000-41 AMI Metering Device Inventory
ATTACHMENT J-1502000-01
DEFINITIONS AND ACRONYMS
DEFINITION DESCRIPTION
CRANE, CATEGORY 1 Portal cranes, Hammerhead cranes, Locomotive cranes, Derricks, Floating cranes (YD), Tower cranes, Container cranes, Mobile cranes (except those indicated as category 4), including truck, cruiser, crawler, warehouse/industrial cranes, and cranes used for dragline, pile driving, clamshell, magnet, bucket work, and Aircraft crash cranes.
CRANE, CATEGORY 2 & 3 Cranes with rated capacities of 20,000 pounds or greater are category 2.
Examples are Overhead traveling cranes, Gantry cranes (rail mounted), Wall cranes, Jib cranes, Pillar cranes, Pillar jib cranes, Monorails and associated hoists, Fixed hoists, including chain falls. Pedestal mounted commercial boom assemblies (fixed length, telescoping, and articulating types) attached to stake trucks, trailers, flatbeds, or railcars, or stationary mounted to piers, etc., with OEM rated capacities less than 2,000 pounds.
CRANE, CATEGORY 4 Commercial truck mounted cranes, Truck mounted articulating boom cranes, Pedestal mounted commercial boom assemblies (fixed length, telescoping, and articulating types) attached to stake trucks, trailers, flatbeds, or railcars, or stationary mounted to piers, etc., with OEM rated capacities of 2,000 pounds and greater. Commercial truck mounted cranes and truck mounted articulating boom cranes with OEM capacities of 2,000 pounds and greater require a licensed operator even if the cranes are down rated below 2,000 pounds capacity for administrative purposes.
EQUIPMENT, COLLATERAL Encompasses built-in and large substantially affixed equipment/property that is normally acquired and installed as part of a facility project.
EQUIPMENT, INSTALLED Encompasses building-type equipment, built-in equipment, and large, substantially affixed equipment/property, and is normally acquired and installed as part of a facility project. Installed equipment is normally required to make a facility useful and operable. Removing such equipment would impair the usefulness, safety, or environment of the facility or the facility restoration work required after its removal, is substantial.
EQUIPMENT, PERSONAL
PROPERTY
Personal property equipment includes all equipment other than collateral equipment. Such equipment, when acquired and used in a facility or a test apparatus, can be severed and removed aster erection or installation without substantial loss of value or damage thereto or to the premises where installed.
FACILITIES LIFE CYCLE A facilities life cycle is divided into four stages, requirements (planning and design), acquisition (construction and acceptance), stewardship (operations, maintenance and repair), and disposal.
FACILITIES MAINTENANCE
MANAGEMENT
The planning, prioritizing, organizing, controlling, reporting, evaluating, and adjusting of facilities maintenance operations to support the CNO/NAVFAC facilities policy and objectives and satisfy customers’ facility needs. Defined by the International Facility Management Association as “the practice of coordinating the physical workplace with the people and work of the organization.”
Integrated Maintenance Program
(IMP)
IMP is a recurring state-of-the-art, reliability-centered inspection, testing, maintenance and repair program that determines best practices for managing the functions and consequences of failures of facilities equipment and system components. IMP encompasses accepted commercial practices, including reactive, preventive, predictive and proactive maintenance, into one optimal program. The IMP approach gives the Contractor full responsibility to maintain systems and equipment and perform repairs whenever necessary to ensure equipment and systems are operational and remain in a constant state of readiness. Service calls will not be issued for accomplishment of repairs on systems and equipment maintained under IMP.
LIFE-CYCLE COSTS A form of economic analysis that considers the total cost of owning, operating, and maintaining a building or system over its useful life.
MAINTENANCE,
PREVENTIVE
Maintenance designed to increase the availability of the facilities/equipment by reducing the number of unexpected breakdowns or service interruptions. It is any planned maintenance activity that improves equipment life and avoid any unplanned maintenance requirements.
MANAGEMENT
INFORMATION SYSTEMS-
MAINTENANCE
A computerized system that will provide sufficient information for management to evaluate differences between budgets and actual costs and evaluate performance.
PROJECT WORK ORDER Any work required to return a facility, system, equipment or component to normal working condition. Project work is intended to allow for the execution of work not defined elsewhere in the contract and is generally issued for work that is not complex in nature and a detailed cost estimate or job plan is not necessary.
PROJECT WORK ORDER,
LEVEL 1
Project work is defined as any work that does not qualify as a service order, but is needed to maintain the agreed upon facility condition.
Maintain means to repair to such a condition that it may be used for its intended purpose and to normal working condition. Includes facility improvements and changes up to $5,000.
PROJECT WORK ORDER,
LEVEL 2
Project work is defined as any work that does not qualify as a service order and exceeds the limits for project work order level 1, but is needed to maintain the agreed upon facility condition. Maintain means to repair to such a condition that it may be used for its intended purpose and to normal working condition. Includes facility improvements and changes up to $10,000.
PROJECT WORK ORDER,
LEVEL 3
Project work is defined as any work that does not qualify as a service order and exceeds the limits for project work order level 2, but is needed to maintain the agreed upon facility condition. Maintain means to repair to such a condition that it may be used for its intended purpose and to normal working condition. Includes facility improvements and changes up to $15,000.
REPAIR Repair is the restoration of facilities or equipment to such a condition that it may be effectively utilized for its designated purposes by overhaul, reconstruction, or replacement of constituent parts or materials which have deteriorated by action of the elements or usage, and which have not been corrected through maintenance. This term also applies to replacement of the entire unit or system if beyond economical repair. The intent of repair is to have the equipment at normal working condition.
REPLACEMENT Replacement, as a distinct work element, is confined to a program of planned replacement of a facility or its components. It may be further limited to major components such as air conditioning compressors, furnaces or hot water heaters. Replacement is performed when the equipment has reached the end of its useful life; when it no longer can perform due to degradation of its internal components and repair is no longer cost effective. Included under the replacement would be the major rebuilding of any component, since rebuilding also restores performance.
RESTORATION Restoration of real property to such a condition that it can be used for its intended purpose. Includes repair or replacement work to restore facilities damaged by inadequate sustainment, excessive age, natural disaster, fire, accident or other causes.
SUSTAINMENT Maintenance and repair activities necessary to keep a typical inventory of facilities in “normal working condition”. Sustainment includes regularly scheduled maintenance as well as cyclical major repairs or replacement of components that occur periodically over the expected service life of the facilities.
SERVICE ORDER Any work required to return a facility, system, equipment or component to normal working condition. Service orders are minor facility problem requests or requests for other non-recurring work that is too small to be planned and estimated.
The purpose of a service order is to provide the Government with a means of issuing work up to a defined liability limit for requirements occurring outside of the specified recurring work. The Government may utilize service orders to accomplish any work up to the respective liability limit based on the service order classification.
SERVICE ORDER CYCLE Count down starts when the customer is notified that the work has been accepted to be accomplished to the time when the work chit is turned in by the craftsmen as complete is one complete cycle period for a service order.
SERVICE ORDER,
EMERGENCY
Emergency is defined as any facility deficiency that immediately compromises the mission or life, health and safety. Always includes, but is not limited to, failure of any utility, fire protection, environmental control, or security alarm systems.
SERVICE ORDER, URGENT Urgent is defined as any deficiency that does not immediately endanger personnel or property, but extended delays of repairs could result in damage to Government property, or soon affect the security, health, or well-being of personnel or the continued operation of a service or system.
SERVICE ORDER, ROUTINE Routine is defined as any work requirement within the defined LOL that does not qualify as emergency or urgent.
WEIGHT HANDLING
EQUIPMENT (WHE)
Weight handling equipment consists of cranes (e.g., portal cranes, jib cranes), rigging gear (e.g., slings, shackles), and associated equipment (e.g., portable hoists, dynamometers). For purposes of this technical sub-annex, WHE does not include mobile or transportable truck, crawler, and railway mounted locomotive cranes covered in 1700000 BSVE.
ACRONYM TITLE
BPVC Boiler and Pressure Vessel Code HVAC Heating, Ventilation, and Air Conditioning NESHAP National Emission Standards of Hazardous Air Pollutants NSPS New Source Performance Standard - EPA RPIE Real Property Inventory Equipment SCADA Supervisory Control And Data Acquisition SRM Sustainment, Restoration and Modernization TJC The Joint Commission UFC Unified Facilities Criteria UPV Unfired Pressure Vessel VTE Vertical Transportation Equipment
ATTACHMENT J-1502000-02
REFERENCES AND TECHNICAL DOCUMENTS
The Contractor shall adhere to the applicable portions of the following publications and directives in performing the services required under this contract. This list shall not be considered all-inclusive and does not release the Contractor from all obligations that must be fulfilled in the observance and execution of this contract.
REFERENCE TITLE
ASME A17.1 Safety Code for Elevators and Escalators ASME A17.2 Guide for Inspection of. Elevators, Escalators, and Moving Walks ASME A18.1 Safety Standard for Platform Lifts and Stairway Chairlifts ASTM E1934 Standard Guide for Examining Electrical and Mechanical Equipment with
Infrared Thermography ANSI A359.1 Fall Protection Code ANSI E1.4-2014 Entertainment Technology - Manual Counterweight Rigging Systems MIL-HDBK-419 Grounding, Bonding, and Shielding for Electronic Equipment and Facilities MIL-STD-188-124B Military Standard: Grounding, Bonding and Shielding for Common Long
Haul/Tactical Communication Systems NFPA Standard 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking
Operations NSPS Subpart IIII Standards of Performance for Stationary Compression Ignition Internal
Combustion Engines NSPS Subpart JJJJ Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines NESHAP Subpart ZZZZ National Emissions Standards for Hazardous Air Pollutants for Stationary
Reciprocating Internal Combustion Engines NAVAIR 51-50AAA-2 General Requirements for Shore-based Airfield Marking and Lighting NAVFACINST 11300.37 Energy and Utilities Policy Manual NAVFAC MO-201 Electric Power Distribution Systems NAVFAC MO-116 Electrical Interior Facilities NAVFAC MO-206 Maintenance and Operation of Air Compressor Plants NAVFAC MO-209 Maintenance of Steam, Hot Water and Compressed Air Distribution Systems NAVFAC MO-912 Maintenance and Operation of Auxiliary Generators NAVFAC P-307 Management of Weight Handling Equipment NAVSEA OP-5 Ammunition and Explosives Safety Ashore OPNAVINST 5090.1 Environmental Readiness Program Manual TM 5-693 Uninterruptible Power Supply System Selection, Installation, and
Maintenance for Command, Control, Communications, Intelligence, Surveillance, and Reconnaissance (C4ISR) Facilities
UFC-3-230-02 O&M: Water Supply Systems UFC 3-410-01 Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02 Direct Digital Control for HVAC and Other Building Control Systems UFC 3-410-06 Central Heating Plants Operation and Maintenance UFC 3-430-07 Operations and Maintenance: Inspection and Certification of Boilers and
Unfired Pressure Vessels UFC 3-460-03 O&M: Maintenance of Petroleum Systems UFC 3-501-01 Electrical Engineering UFC 3-560-01 Operation and Maintenance: Electrical Safety UFC 3-570-06 Cathodic Protection Systems UFC 3-601-02 Operations and Maintenance: Inspection, Testing, and Maintenance of Fire
Protection Systems UFC 4-010-06 Cybersecurity of Facility-Related Control Systems UFC 4-021-01 Design and O&M: Mass Notification Systems UG-2029-ENV Cross-Connection Control and Backflow Prevention Program
ATTACHMENT J-1502000-02
REFERENCES AND TECHNICAL DOCUMENTS
Implementation at Navy Shore Facilities
40 CFR 60 Standards of Performance for New Stationary Sources 40 CFR 63 National Emission Standards for Hazardous Air Pollutants for Source
Categories 40 CFR 89 Control of Emissions From New and In-Use Non-road Compression-Ignition
Engines.
ATTACHMENT J-1502000-03
FACILITY INVENTORY
The Facility Property Inventory I provided as a separate attachment. Refer to Excel attachment “J-1502000-03 Facility Inventory” with the following tabs:
Tab 001 – MCB QUANTICO FACILITY PROPERTY INVENTORY Tab 002 – MCAF FACILITY PROPERTY INVENTORY
ATTACHMENT J-1502000-04
HISTORICAL SERVICE ORDER WORKLOAD
ESTIMATED ANNUAL REQUIREMENTS
Notes: Service orders historical data is intended to provide information relative to probable customer use for pricing purposes. The number of service orders used by any individual customer is not limited to the number displayed in the chart and can be adjusted by a contract modification as per Annex 2, Spec Item 2.16.
Funding Activity Emergency Urgent Routine Total Service Orders
MCBQ 20 25 25 70
NAVHOSP/HMX1 - BUMED 2 10 50 62
NMMC Museum 5 2 221 228
MANPOWER 12 12 12 36
MCAF 6 6 300 312
MCCOG 5 10 20 35
MCIA 15 6 25 46
MCIOC 3 3
MCU 6 96 102
G6 36 36
TOTAL 71 71 788 930
ATTACHMENT J-1502000-05
HISTORICAL PROJECT WORK ORDER WORKLOAD
ESTIMATED ANNUAL REQUIREMENTS
Notes: Work orders historical data is intended to provide information relative to probable customer use for pricing purposes. The number of work orders used by any individual customer is not limited to the number displayed in the chart and can be adjusted by a contract modification as per Annex 2, Spec Item 2.16.
Funding Activity Proj Order Level 1 Proj Order Level
Proj Order Level 3 Total Project Orders
MCBQ 5 3 1 9
NAVHOSP/HMX1 - BUMED
NMMC Museum 2 1 3
MANPOWER
MCAF 5 3 8
MCCOG 1 1 2 4
MCIA
MCIOC
MCU
G6
TOTAL 13 8 3 24
ATTACHMENT J-1502000-06
TEMPERATURE STANDARDS
Area Cooling Season* Heating Season* Living & Admin. Areas (Inactive Employment) 78 68
Working Areas (Active Employment) 78 68
Storage Areas 78 40
Computer Areas 70 68
Training Areas 75 68
*Degrees F. dry bulb
REFRIGERATION SYSTEMS
Type Degrees F.
Frozen Meat 0 to -5
Fresh Meat 30 to 34
Ice Storage 28 to 30
Dairy Products 32 to 34
Ice Cream 0 to -5
Beer 35 to 39
Fruits and Vegetables 36 to 42
Chill Room 35 to 39
ATTACHMENT J-1502000-07
HVAC AND REFRIGERATION SYSTEMS EQUIPMENT INVENTORY
The HVAC and Refrigeration Systems equipment inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-07 HVAC and Refrigeration Systems Inventory” with the following tabs:
Tab 001 – TECOM Tab 002 – NMCL Tab 003 – NMMC Tab 004 – MANPOWER Tab 005 – MCAF Tab 006 – MCCOG Tab 007 – MCIA Tab 008 – MCIOC Tab 009 – MCU Tab 010 – G6
ATTACHMENT J-1502000-08
INTERIOR AND EXTERIOR LIGHTING SYSTEMS INVENTORY
The Interior and Exterior Lighting Systems equipment inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-08 Interior and Exterior Lighting Systems Equipment Inventory” with the following tabs:
Tab 001 – NMCL Tab 002 – NMMC Tab 003 – MCAF Tab 004 – MCU
ATTACHMENT J-1502000-09
BOILERS AND UPVs EQUIPMENT INVENTORY
The Boiler and UPVs inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-09 Boilers and UPVs Inventory” with the following tabs:
Tab 002 – MCAF Tab 003 – MCCOG Tab 004 – MCIOC Tab 005 – MCU
ATTACHMENT J-1502000-10
CATHODIC PROTECTION SYSTEMS INVENTORY
The Cathodic Protection Systems equipment inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-10 Cathodic Protection Systems Inventory” with the following tab:
Tab 001 – MCBQ
ATTACHMENT J-1502000-11
LIGHTNING ARRESTORS AND GROUNDING DEVICES INVENTORY
The Lightning Arrestors and Grounding Devices inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-11 Lighting Arrest and Ground Devices Inventory” with the following tab:
ATTACHMENT J-1502000-12
FIRE PROTECTION SYSTEMS INVENTORY
The Fire Protection Systems equipment inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-12 Fire Protection Systems Inventory” with the following tabs:
Tab 002 – NMCL Tab 003 – NMMC Tab 004 – MCAF Tab 005 - DODEA
ATTACHMENT J-1502000-13
AUXILIARY GENERATORS INVENTORY
The Auxiliary Generators inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-13 Auxiliary Generators Inventory” with the following tabs:
Tab 003 – MANPOWER Tab 004 – MCAF Tab 005 – MCCOG Tab 006 – MCIA Tab 007 – MCIOC Tab 008 – MCSC
ATTACHMENT J-1502000-14
UNINTERRUPTED POWER SYSTEMS (UPS) INVENTORY
The Uninterrupted Power Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-14 UPS Inventory” with the following tabs:
Tab 001 – NMMC Tab 002 – MANPOWER Tab 003 – MCAF Tab 004 – MCCOG Tab 005 – MCIA Tab 006 – MCIOC Tab 007 – MCU
ATTACHMENT J-1502000-15
VEHICLE BARRIER AND GATE SYSTEM INVENTORY
The Vehicle Barrier and Gate Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-15 Vehicle Barrier and Gate System Inventory” with the following tab:
ATTACHMENT J-1502000-16
WEAPONS BLUING EQUIPMENT INVENTORY
Funding Activity: MCBQ
Bluing System PH Control
Phase-DuLite pH10
The Weapons bluing equipment is located in Building 27250 and is manufactured by Du-Lite Corporation.
There are four systems: one consists of two tanks, one has three tanks and two have four tanks. Each tank holds 30 gallons.
The ventilation system has ducting leading to the roof where the exhaust fan is located. The control panel is located on an adjacent wall.
Tank System with Exhaust System
Controls
Exhaust Fan (located on roof)
Duct Label
ATTACHMENT J-1502000-17
EMERGENCY AND EXIT LIGHTING SYSTEMS INVENTORY
The Emergency and Exit Lighting Systems inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-17 Emergency and Exit Lighting Systems Inventory” with the following tab:
ATTACHMENT J-1502000-18
VERTICAL TRANSPORTATION EQUIPMENT (VTE) INVENTORY
The Vertical Transportation Equipment inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-18 VTE Inventory” with the following tabs:
Tab 002 – MCCOG
ATTACHMENT J-1502000-19
AIRFIELD LIGHTING SYSTEMS INVENTORY
The Airfield Lighting Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-19 Airfield Lighting Systems Inventory” with the following tab:
Tab 001 – MCAF
ATTACHMENT J-1502000-20
ROLL-UP, OVERHEAD AND AUTOMATED DOORS INVENTORY
The Roll-Up, Overhead and Automated Doors inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-20 Roll-Up, Overhead and Auto Doors Inventory” with the following tabs:
Tab 003 – MCCOG Tab 004 - MCSC
ATTACHMENT J-1502000-21
EMERGENCY EYEWASH AND SHOWER STATION INVENTORY
The Emergency Eyewash and Shower Station inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-21 Emergency Eyewash and Shower Station Inventory” with the following tabs:
Tab 002 – MCSC Tab 003 – MCU
ATTACHMENT J-1502000-22
LIFTS AND MOBILE SCAFFOLDS INVENTORY
The Lifts and Mobile Scaffolds inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-22 Lifts and Mobile Scaffolds Inventory” with the following tab:
ATTACHMENT J-1502000-23
RAINWATER HARVESTING SYSTEMS INVENTORY
The Rainwater Harvesting Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-23 Rainwater Harvesting Systems Inventory” with the following tab:
Tab 001 – MCCOG
ATTACHMENT J-1502000-24
BUILDING CONTROL SYSTEMS INVENTORY
The Buildings Control Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-24 Building Control Systems Inventory” with the following tabs:
Tab 003 – MCCOG Tab 004 – MCU Tab 005 – MCIOC Tab 006 - MCIA
ATTACHMENT J-1502000-25
FACILITY ELECTRICAL SYSTEMS INVENTORY
The Facility Electrical Systems Equipment inventory by Funding Activities is provided as a separate attachment.
Refer to Excel attachment “J-1502000-25 Facility Electrical Systems Inventory” with the following tabs:
Tab 003 – MCIOC Tab 004 – MCU
ATTACHMENT J-1502000-26
PUMPS INVENTORY
The Pumps inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J- 1502000-26 Pumps Inventory” with the following tab:
Tab 001 – MCU
ATTACHMENT J-1502000-27
ORNAMENTAL FOUNTAINS INVENTORY
The Pumps inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J- 1502000-27 Ornamental Fountains Inventory” with the following tab:
Tab 001 – MCU
ATTACHMENT J-1502000-28
PLANT SYSTEMS EQUIPMENT INVENTORY
The Plant Systems Equipment inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-27 Plant Systems Equipment Inventory” with the following tabs:
ATTACHMENT J-1502000-29
BACKFLOW PREVENTION DEVICES INVENTORY
The Backflow Prevention Devices inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-29 Backflow Prevention Devices Inventory” with the following tabs:
Tab 003 – MCAF Tab 004 – MCCOG Tab 005 – MCIOC Tab 006 – MCU
ATTACHMENT J-1502000-30
RESERVED
This attachment is left intentionally blank.
ATTACHMENT J-1502000-31
FALL PROTECTION SYSTEMS INVENTORY
The Fall Protection Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-31 Fall Protection Systems Inventory” with the following tab:
ATTACHMENT J-1502000-32
GREASE TRAPS INVENTORY
The Grease Traps inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-32 Grease Traps Inventory” with the following tabs:
ATTACHMENT J-1502000-33
EXHAUST HOODS AND DUCT INVENTORY
The Exhaust Hoods and Ducts inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-33 Exhaust Hoods and Duct Inventory” with the following tabs:
Tab 004 – DoDEA
ATTACHMENT J-1502000-34
HVAC WATER TESTING AND TREATMENT SERVICES INVENTORY
The HVAC Water Testing and Treatment Services inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-34 HVAC Water Testing and Treatment Services Inventory” with the following tabs:
• Tab 001 – MCBQ
ATTACHMENT J-1502000-35
BOILER WATER TESTING AND TREATMENT SERVICES INVENTORY
The Boiler Water Testing and Treatment Services inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-35 Boiler Water Testing and Treatment Services Inventory” with the following tabs:
• Tab 001 – MCBQ
ATTACHMENT J-1502000-36
OIL WATER SEPARATORS (OWS) INVENTORY
The Oil Water Separators inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-36 Oil Water Separators Inventory” with the following tabs:
Tab 002 – MCAF
ATTACHMENT J-1502000-37
DRINKING FOUNTAINS INVENTORY
The Drinking Fountains/Water Coolers inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-37 Drinking Fountains Inventory” with the following tabs:
Tab 003 – MCU
ATTACHMENT J-1502000-38
BUILDING DRAINAGE SYSTEMS INVENTORY
The Building Drainage Systems inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-38 Building Drainage Systems Inventory” with the following tabs:
ATTACHMENT J-1502000-39
SOLAR PANELS MAINTENANCE INVENTORY
The Solar Panels inventory by Funding Activities is provided as a separate attachment. Refer to Excel attachment “J-1502000-39 Solar Panels Inventory” with the following tabs:
ATTACHMENT J-1502000-40
COMPRESSED NATURAL GAS SYSTEM INVENTORY
The Compressed Natural Gas System inventory is provided as a separate attachment. Refer to Excel attachment “J- 1502000-40 Compressed Natural Gas System Inventory” with the following tabs:
Tab 001 – Compressed Natural Gas System Inventory
ATTACHMENT J-1502000-40.a
INSPECTION CHECKLIST
The Compressed Natural Gas Inspection Checklist is provided as a separate attachment. Refer to Word Document attachment “J-1502000-40.a Inspection Checklist”.
ATTACHMENT J-1502000-41
ADVANCED METERING INFRASTRUCTURE (AMI) - METERING DEVICE INVENTORY
The AMI Metering Device inventory is provided as a separate attachment. Refer to Excel attachment “J-1502000- 41 AMI Metering Device Inventory” with the following tabs:
Tab 001 – AMI Inventory