60042069_Rev03.pdf

PDF 558 KB Posted

Attached to
Mechanical Repairs Bldg TT113 CDC
Solicitation number
N4008526R9010
Issued by

About this file

This document is a mechanical HVAC design drawing for Building TT113 at Marine Corps Base Camp Lejeune, North Carolina. The drawing depicts the First Floor Plan - West Wing - Mechanical HVAC system layout at a scale of 3/16" = 1'-0" and is identified as Sheet B1 of 119 pages within the contract documentation.

The drawing shows the distribution of heating, ventilation, and air conditioning components throughout the first floor west wing of the facility, which contains multiple pretoddler classrooms (101-108), a toddler room (144), training specialist office (110), staff training area (111), administrative office (112), director's office (114), and associated closets and corridor spaces. The mechanical system includes 4-pipe fan coil units positioned above gypsum board ceilings with supply and return ductwork routed down through ceilings to lay-in ceiling grilles, duct-mounted balancing dampers, ventilation ductwork from a dedicated outdoor air system (DOAS) in the attic, and exhaust ductwork routed to sidewall-mounted grilles. Equipment is designated with standardized codes (S1, S2, S3, S4, E5, R2, R3, R4, R5, FCU-1, FCU-2) and duct dimensions ranging from 4 inches to 20 inches. The construction contract number is N40085-24-F-5940, with the drawing prepared under Naval Facilities Engineering Systems Command (NAVFAC) and identified by specification MH104 and MBFA number 60042069.

View the file

Other files

File Type Posted
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
M-202-T.pdf PDF
Amend 0012.pdf PDF
60042049 _Rev03.pdf PDF
60042066_Rev03.pdf PDF
Amend 0011.pdf PDF
60042073_Rev03.pdf PDF
60042047 _Rev03.pdf PDF
60042070_Rev03.pdf PDF
N4008523B0044 PPI Revision 03.pdf PDF
Amend 0010.pdf PDF
Amend 0010 Enclosure 3 DWGS.pdf PDF
Amend 0010 Enclosure 1 DWG List.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0004.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0003.pdf PDF
Amend 0002 SECTION 01 31 50 TRANSFER AND ACCEPTANCE OF MILITARY REAL PROPERTY.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
230044 Termite Inspection Report.pdf PDF
Mech MACC RFP.pdf PDF
N4008523B0044 Specs.pdf PDF
230044 SID Binder.pdf PDF
230044 Basis of Design.pdf PDF
230044 Lead and Asbesto Report.pdf PDF
230044 APPD.pdf PDF
N4008523B0044 Dwgs.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FCU-2-05

F C

U -2

-0

FCU-2-08

F C

U -2

-0

FCU-2-02

FCU-2-03

F

C U

-2 -0

FCU-2-09

FCU-2-11

FCU-2-07

FCU-2-12

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

TRAINING SPECIALIST

STAFF TRAINING

OFFICE

DIRECTOR

CLOSET

101A

CLOSET

102A

CLOSET

103A

CLOSET

104A

CLOSET

105A

CLOSET

108A

CLOSET

107A

CLOSET

106A

PRETODDLER

CORRIDOR

CLOSET

102A

CLOSET

103A

CLOSET

107A

CLOSET

106A

TODDLER

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S4

S4

S2

S2

S2

"ø

"ø

"ø1

"ø

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

"x

8"ø

8"ø8"ø

8"ø

8"ø

"x

8"ø

12"ø

8"ø

"x

"ø

"x

"x

"x

"x

"8"ø

8"ø

"x

8"ø

8"ø

"x

"ø

T T T T

T T T

T

T

T

T

E5

E5

E5

E5

E5

E5

E5

E5

8"ø

S2

S2

S2

S2

R5

R5

8"ø 8"ø

S2

R5

S2

8"ø

8"ø

S2

S2

S2

R5

S2

S2

S2

"ø

8"ø

S2

S2

S2

8"ø

8"ø

"ø

R5

R5

S2

S2

S2

"ø

R5

S2

8"ø

S2

S2

8"ø

S2

S2

S2

8"ø 8"ø

8"ø8"ø 8"ø

"ø

8"ø

"ø

8"ø 8"ø

8"ø

8"ø 8"ø

S3

S3

S2

"x

"ø

"ø

S1

4"ø

8"ø

S2

"ø

FCU-1-02

FCU-1-01

R4

"x

FCU-2-10

12"ø

S2

10"ø R5

R2

R2

R5

R2

8"ø

S2

S2

R5

R3

S2

"ø

"ø

OFFICE

117A

OFFICE

T

T T

"ø

"x

4"ø

14"ø

10"ø

8"ø

8"x12"

"x

"x

8"ø

"x

12"ø

"x

"ø

14"ø

20"x12"

R4

12"ø 10"x12"

"x

"x

14"ø

8"ø

14"ø

"ø

8"ø 8"ø

8"ø

"x

8"ø

8"ø

8"ø

8"ø

8"ø

8"ø

14"ø

"x

8"ø

8"ø

14"ø

"x

8"ø

8"ø

"ø

"ø

"ø

"ø

"ø

3 3

S1

S1

"ø

"ø

"ø

"ø

SYM. DESCRIPTION DATE APP.

REVISIONS

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

MH104

PJR

JDL

JENNI REED

LWM

MECHANICAL REPAIRS

BUILDING TT113

FIRST FLOOR PLAN - WEST WING - MECHANICAL HVAC

60042069 N40085-24-F-5940

GENERAL NOTES:

# PLAN NOTES

1 PROVIDE 4-PIPE FAN COIL UNIT ABOVE SECOND

GYPSUM BOARD CEILING. PROVIDE RETURN

DUCT PLENUM TO MATCH DUCT INLET

CONNECTION. PROVIDE TRANSITION OR TAP AS

SHOWN AND ROUTE SUPPLY AND RETURN

DUCTWORK DOWN THROUGH GYP CEILING TO

LAY-IN CEILING GRILLES. PROVIDE DUCT

MOUNTED BALANCING DAMPER BETWEEN GYP

CEILING AND GRILLE.

2 PROVIDE VENTILATION DUCTWORK DOWN FROM

DOAS MAIN DUCTWORK IN ATTIC, TO LAY-IN

CEILING MOUNTED GRILLES AS SHOWN. SEE

ATTIC PLANS FOR CONTINUATION. (TYPICAL)

3 PROVIDE EXHAUST DUCTWORK DOWN FROM

DOAS MAIN DUCTWORK IN ATTIC. ROUTE TO

VERTICAL EXHAUST DUCTWORK IN CHASE

DOWN TO SIDEWALL MOUNTED GRILLE AS

SHOWN. (TYPICAL)

GRAPHIC SCALE: 3/16"=1'-0"

6' 0 4' 10'

3/16" = 1'-0" B1

FIRST FLOOR PLAN - WEST WING - MECHANICAL HVAC

1. SEE SHEET M-001 FOR GENERAL NOTES,

LEGEND & ABBREVIATIONS

2. PLAN DRAWINGS ARE DIAGRAMMATIC IN

NATURE AND DO NO ILLUSTRATE SPECIFIC

DUCT TAKE-OFF CONFIGURATIONS OR TAPS.

3. FAN COIL UNITS AND ASSOCIATED DUCTWORK

SHOWN IS LOCATED IN ATTIC AND SHOWN ON

FLOOR PLANS FOR COORDINATION PURPOSES

ONLY. SEE ATTIC AND SECTION VIEWS FOR

ELEVATIONS AND LOCATIONS OF EQUIPMENT.

N

NTS

A5

KEY PLAN - WEST WING

2 PPI REVISION 2 03.09.26

3 PPI REVISION 3 03.31.26

File details come from the government source that posted it. Updated .