230044 Lead and Asbesto Report.pdf
PDF 5 MB Posted
- Attached to
- Mechanical Repairs Bldg TT113 CDC
- Solicitation number
- N4008526R9010
About this file
This is an environmental assessment report documenting the results of an asbestos, lead paint, and mold survey conducted at Tarawa Terrace II Child Development Center (Building TT-113) located at Camp Lejeune, North Carolina. The assessment was performed by ECS Southeast, LLC on August 30, 2024, for MBF Architects PA in preparation for planned interior and exterior renovations to the building.
The survey included collection and analysis of 23 bulk samples from 11 homogeneous areas (31 layers analyzed) for asbestos content using Polarized Light Microscopy per EPA Method 600/R-93/116, 13 paint chip samples for lead concentration via Flame Atomic Absorption Spectroscopy, and a visual inspection for visible mold and moisture. All asbestos bulk samples tested negative for detectable concentrations of asbestos. All 13 paint chip samples tested below laboratory detection limits for lead, with results ranging from <0.0028% to <0.0074% by weight. No visible mold or moisture was observed during the assessment; however, ceiling tiles had been previously replaced due to HVAC condensation. The report notes that unseen asbestos-containing materials may remain hidden in inaccessible areas such as sub-grade walls, structural members, and areas behind exterior walls, and recommends that any suspect materials discovered during construction activities be sampled and tested by a certified asbestos inspector in accordance with 29 CFR 1926.1101. The assessment was completed with certifications from inspectors holding valid North Carolina asbestos and lead certification credentials.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| M-202-T.pdf | ||
| Amend 0012.pdf | ||
| 60042049 _Rev03.pdf | ||
| 60042066_Rev03.pdf | ||
| Amend 0011.pdf | ||
| 60042073_Rev03.pdf | ||
| 60042047 _Rev03.pdf | ||
| 60042070_Rev03.pdf | ||
| N4008523B0044 PPI Revision 03.pdf | ||
| 60042069_Rev03.pdf | ||
| Amend 0010.pdf | ||
| Amend 0010 Enclosure 3 DWGS.pdf | ||
| Amend 0010 Enclosure 1 DWG List.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0004.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002 SECTION 01 31 50 TRANSFER AND ACCEPTANCE OF MILITARY REAL PROPERTY.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 230044 Termite Inspection Report.pdf | ||
| Mech MACC RFP.pdf | ||
| N4008523B0044 Specs.pdf | ||
| 230044 SID Binder.pdf | ||
| 230044 Basis of Design.pdf | ||
| 230044 APPD.pdf | ||
| N4008523B0044 Dwgs.pdf |
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS, LEAD PAINT, AND MOLD
ASSESSMENT
TARAWA TERRACE II CHILD DEVELOPMENT CENTER
BLDG. TT-113 IWO JIMA BOULEVARD
TARAWA TERRACE, NORTH CAROLINA 28547
ECS PROJECT NO. 49:23942
FOR: MBF ARCHITECTS PA
SEPTEMBER 24, 2024
September 24, 2024
Mr. Bill Faulkenberry MBF Architects PA 317-C Pollock Street New Bern, North Carolina 28560
ECS Project No. 49:23942
Reference: Asbestos, Lead Paint, and Mold Assessment, Tarawa Terrace II Child Development Center, Bldg. TT-113 Iwo Jima Boulevard, Tarawa Terrace, North Carolina
Dear Mr. Faulkenberry:
ECS Southeast, LLC (ECS) is pleased to provide MBF Architects PA with the results of the above referenced Asbestos, Lead Paint, and Mold Assessment performed at the Tarawa Terrace II Child Development Center located at Bldg. TT-113 Iwo Jima Boulevard in the Tarawa Terrace subdivision at Camp Lejeune, North Carolina. This report summarizes our observations, analytical results, findings, and recommendations related to the work performed. The work described in this report was performed by ECS in general accordance with the Scope of Services described in ECS Proposal Number 49:43086P and the terms and conditions of the agreement authorizing those services.
ECS appreciates this opportunity to provide MBF Architects PA with our services. If we can be of further assistance to you, please do not hesitate to contact us.
Sincerely, ECS Southeast, LLC
Braxton B. Dawson Lindsey Thompson, REM Environmental Project Manager Environmental Principal bdawson@ecslimited.com lthompson@ecslimited.com 910-686-9114 864-987-1810
6714 Netherlands Drive, Wilmington, North Carolina 28405 • T:910-686-9114 NC Engineering No. F-1519 NC Geology No. C-553 SC Engineering No. 3239
ECS Florida, LLC • ECS Mid-Atlantic LLC • ECS Midwest, LLC • ECS Pacific, Inc. • ECS Southeast, LLC • ECS Southwest, LLP
ECS New York Engineering, PLLC - An Associate of ECS Group of Companies • ecslimited.com
"ONE FIRM. ONE MISSION."
EXECUTIVE SUMMARY
The subject property is improved with Building TT-113 located at Iwo Jima Boulevard in Tarawa Terrace, Camp Lejeune, Onslow County, North Carolina. It is slated for interior and exterior renovations. The structure on the property is a single-story building utilized as the Tarawa Terrace II Child Development Center (CDC). The site features paved access from Iwo Jima Blvd, with a parking area to the north of the building. The building is currently occupied and is slated for interior and exterior renovations. ECS was contracted to perform an asbestos, lead paint, and mold assessment at the building prior to the proposed renovations.
The purpose of the survey was to determine whether asbestos-containing materials (ACMs), lead-containing paint (LCP), and visible mold are present on the subject property. The survey was performed within the interior and exterior areas of the subject building as well as the roof.
Asbestos Survey
On August 30, 2024, Mr. Braxton B. Dawson, a North Carolina state-certified inspector, performed the asbestos assessment. Bulk samples were submitted to Scientific Analytical Institute, Inc. (SAI) in Greensboro, North Carolina for analysis via Polarized Light Microscopy (PLM) in accordance with the current EPA-600 methodology.
A total of twenty-three (23) bulk samples from eleven (11) homogeneous areas were submitted to the laboratory, of which thirty-one (31) layers were analyzed. Based on the laboratory analysis of the bulk samples collected during the survey, none of the materials were reported to contain asbestos.
Due to inaccessibility or the destructive means that asbestos sampling requires, unseen ACMs may remain within the building hidden behind inaccessible areas, which include, but are not limited to, sub-grade walls, structural members, topping slabs, sub-grade sealants, flooring located below underlayments, areas behind exterior walls, pipe trenches, and subsurface utilities.
If suspect materials are discovered during construction activities, they should be presumed to contain asbestos and be treated as ACMs or be sampled immediately upon discovery and prior to disturbance for asbestos content by an accredited or certified asbestos inspector in accordance with 29 Code of Federal Regulations (CFR) 1926.1101.
Lead Paint Survey
The lead paint assessment was conducted by collection of paint chip samples from suspect lead paint materials. The paint chip samples were submitted to a laboratory that participates in the American Industrial Hygiene Association (AIHA) Environmental Lead Proficiency Analytical Testing (ELPAT) Programs for analysis of lead concentration (percent by weight) using Flame Atomic Absorption Spectroscopy.
Based on the laboratory analysis of the paint chips collected during the survey, lead was not detected above the laboratory detection limit.
ii
Paint and surface coatings that contain detectable concentrations of lead are considered “lead-containing paints.” Since OSHA has no specific action level for lead in paint, all paint on the site found to have a measurable concentration of lead should be assumed to be lead-containing. Work performed that may disturb lead-containing paint is regulated under OSHA, as referenced under 29
CFR 1926.62.
Visible Mold Assessment
ECS did not observe evidence of visible mold or moisture during our assessment. However, it was reported that ceiling tiles had been replaced due to HVAC condensation as part of routine maintenance activities. ECS does not recommend additional assessment pertaining to mold at this time.
The executive summary is an integral portion of this report, however, ECS recommends the report be read in its entirety.
iii
PAGETABLE OF CONTENTS
1.0 SITE DESCRIPTION
2.0 PURPOSE
3.0 METHODOLOGY
3.1 Asbestos-Containing Materials
3.2 Lead in Paint and Surface Coatings
3.3 Visible Mold
4.0 RESULTS
4.1 Asbestos Sampling
4.2 Suspect or Assumed Asbestos-Containing Materials
4.3 Lead in Paint and Surface Coatings
4.4 Visible Mold and Moisture
4.4.1 Observations and Findings
5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS
5.1 Asbestos-Containing Materials
5.2 Lead in Paint and Surface Coatings
5.3 Mold and Moisture
6.0 LIMITATIONS
iv
TABLE OF APPENDICES
Appendix I: Figures
Appendix II: Site Photographs
Appendix III: Asbestos Bulk Sample Results
Appendix IV: Lead Laboratory Analytical Results
Appendix V: Certifications/Licenses v
1.0 SITE DESCRIPTION
The subject property is improved with Building TT-113 located at Iwo Jima Boulevard in Tarawa Terrace, Camp Lejeune, Onslow County, North Carolina. It is slated for interior and exterior renovations. The structure on the property is a single-story building utilized as the Tarawa Terrace II Child Development Center (CDC). The site features paved access from Iwo Jima Blvd, with a parking area to the north of the building. The building is currently occupied and is slated for interior and exterior renovations. ECS was contracted to perform an asbestos, lead paint, and visible mold assessment in the building prior to the proposed renovations.
The building construction includes concrete masonry unit (CMU) walls with brick veneer façade, light-gauge steel framing, and a pitched standing seam metal roof system on a concrete slab foundation. Interior finishes include CMU walls, suspended ceiling tiles, gypsum upper ceilings, gypsum recessed skylights, aluminum framed windows, sheet vinyl flooring, and various styles of vinyl composite tiles (VCT).
2.0 PURPOSE
The purpose of the Asbestos, Lead Paint, and Mold Assessment was to identify asbestos-containing materials (ACM), lead-containing paint (LCP), and visible mold which may require special handling and/or disposal if disturbed during construction activities. The identification of ACMs requires trained labor, regulated work practices, and special disposal. The identification of LCP or other lead hazards requires disclosure to contractors and monitoring of lead exposure.
3.0 METHODOLOGY
ECS performed the authorized Scope of Services in general accordance with our proposal, standard industry practice(s) and methods specified by regulation(s) for the identification of ACMs.
3.1 Asbestos-Containing Materials
The asbestos survey was performed by Mr. Braxton B. Dawson (NC Asbestos Inspector No. 12830) on August 30, 2024. The survey consisted of observing the accessible areas of the building for the presence of suspect materials that may contain asbestos. The survey involved detecting both friable materials (materials that can be pulverized or reduced to a powder by hand pressure when dry) and non-friable materials (materials that pose a hazard when sawn, sanded, drilled, or pulverized).
Homogeneous materials (based on material type, color, texture, etc.) were identified during the survey.
The EPA National Emissions Standard for Hazardous Air Pollutants (NESHAP) requires a survey for asbestos before renovation or demolition. Demolition is defined under NESHAP as the removal of a load-bearing structural member, and renovation is an action that disturbs building materials. Based on requirements under NESHAP and North Carolina Asbestos Hazard Management Program (AHMP), administered by the Health Hazards Control Unit (HHCU) for renovation or demolition activities, ECS conducted a limited survey for potential ACM. The ACM survey was limited in that we did not conduct demolition, such as jack/sledgehammering, to expose potentially concealed materials. Samples were
September 24, 2024
ECS Project # 49:23942 collected in general accordance with Environmental Protection Agency (EPA) Standard 40 CFR 763 Subpart E, Asbestos Hazard Emergency Response Act (AHERA), and Occupational Safety and Health Administration (OSHA) Standard 29 CFR 1926.1101 Inspection Protocol.
Representative bulk samples were collected, placed in sealed packages, and submitted to SAI for analysis using the Environmental Protection Agency (EPA) recommended method of Polarized Light Microscopy (PLM) coupled with dispersion staining (Method No. EPA 600/R-93/116). SAI participates in the National Voluntary Laboratory Accreditation Program (NVLAP). Their NVLAP accreditation number is 200664-0. Several of the samples were layered and analyzed as multiple samples. EPA regulations require collecting multiple samples of each homogeneous area for laboratory analysis. The material type, sample location, and analytical results of each bulk sample are also summarized in the attached Asbestos Bulk Analysis report in Appendices.
Samples were analyzed using the “Positive Stop” methodology. If one sample of a homogeneous material is reported to contain asbestos, the remaining samples are not analyzed. If one sample of a material from a homogeneous area is reported to contain greater than 1% asbestos, then by EPA definition, it is characterized as an ACM regardless of additional analysis.
During the survey, ECS attempted to identify suspect ACMs in readily accessible areas. However, due to the destructive means required to identify some materials, certain areas were deemed inaccessible (i.e. behind walls or sub-grade materials) and were not surveyed for suspect ACMs.
3.2 Lead in Paint and Surface Coatings
ECS completed a lead paint screening within the building as part of our assessment activities. The collection of representative paint chip samples was performed throughout the interior and exterior of the building. Samples collected were containerized, labeled, and transported to SAI. Each of the paint chip samples were subsequently analyzed for the presence of lead reported in percent lead by weight via EPA Method SW 846, 7000B (Flame AAS). The chain-of-custody, which includes sample numbers and sample locations, is included in an Appendix of this report.
3.3 Visible Mold
The assessment included a non-invasive visual and olfactory survey for evidence of mold and moisture within the subject property. The assessment focused on the areas of the building to be renovated. The ECS site personnel observed readily accessible areas and selected building materials to evaluate visible suspect fungal growth and/or moisture-impacted materials. A reasonable effort was made to identify water and mold-impacted areas; however, this does not imply a guarantee that all possible reservoirs of mold were identified because mold or water-impacted building materials may be hidden by walls, flooring, partitions, etc.
As is the case with many assessments of this nature, this evaluation was limited to the areas of the property deemed reasonably accessible by ECS. Reasonable effort was made to identify mold and moisture-impacted areas. However, mold/moisture-impacted areas may remain unidentified.
4.0 RESULTS
The following is a summary of laboratory results, findings and observations.
September 24, 2024
4.1 Asbestos Sampling
A total of twenty-three (23) bulk samples from eleven (11) homogeneous areas were submitted to the laboratory, of which thirty-one (31) layers were analyzed.
An ACM is defined as any material containing more than one percent (>1%) asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, PLM. Materials are categorized by the U.S. EPA in the following categories:
• Friable ACMs are defined as any ACM that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable ACMs are defined as any ACM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
• Category I non-friable ACMs include packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than one percent (>1%) asbestos.
• Category II non-friable ACM are listed as any material, excluding Category I non-friable ACM, containing more than one percent (>1%) asbestos.
Regulated Asbestos Containing Materials (RACM) are friable ACM or non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading or has crumbled, been pulverized, or reduced to powder in the course of renovation and/or demolition operations.
SAI submitted a signed final laboratory report to ECS on September 11, 2024. None of the bulk samples submitted for analysis were reported to contain asbestos in detectable concentrations.
A complete list of the sampled materials submitted for analysis and material locations are included below. Sample locations can be found in Appendix I and photographs are located in Appendix II.
Analytical results of each material are also summarized in the attached Asbestos Bulk Analysis report in Appendix III.
Asbestos Bulk Sample Locations and Analysis Results
Sample ID Material Location
Material Description
Analytical Results
Category Estimated Quantity
HA1-1 Mechanical/ Electrical Room
White TSI Sealant
ND (None Detected)
N/A (Not Applicable)
N/A
HA1-2 Mechanical/ Electrical Room
White TSI Sealant
ND N/A N/A
HA2-1 Mechanical/ Electrical Room
Red Firestop Caulk
ND N/A N/A
September 24, 2024
Sample ID Material Location
Material Description
Analytical Results
Category Estimated Quantity
HA2-2 Mechanical/ Electrical Room
Red Firestop Caulk
ND N/A N/A
HA3-1 Mechanical/ Electrical Room
Drywall and Joint Compound
ND N/A N/A
HA3-2 Mechanical/ Electrical Room
Drywall and Joint Compound
ND N/A N/A
HA4-1 Throughout Building Structure
Drywall and Joint Compound Attic Upper Ceiling
ND N/A N/A
HA4-2 Throughout Building Structure
Drywall and Joint Compound Attic Upper Ceiling
ND N/A N/A
HA5-1 Throughout Building Structure
2x2 Smooth CT Lower Ceiling Grid
ND N/A N/A
HA5-2 Throughout Building Structure
2x2 Smooth CT Lower Ceiling Grid
ND N/A N/A
HA6-1-A Toddler Classroom Baths
Beige Sheet Vinyl
ND N/A N/A
HA6-1-B Toddler Classroom Baths
Beige Sheet Vinyl
ND N/A N/A
HA6-2-A Toddler Classroom Baths
Beige Sheet Vinyl
ND N/A N/A
HA6-2-B Toddler Classroom Baths
Beige Sheet Vinyl
ND N/A N/A
September 24, 2024
Location
Material Description
Analytical Results
Category Estimated Quantity
HA7-1-A Throughout Building Flo oring
Grey 12"
VCT&
Mastic
ND N/A N/A
HA7-1-B Throughout Building Flo oring
Grey 12"
VCT&
Mastic
ND N/A N/A
HA7-2-A Throughout Building Flo oring
Grey 12"
VCT&
Mastic
ND N/A N/A
HA7-2-B Throughout Building Flo oring
Grey 12"
VCT&
Mastic
ND N/A N/A
HA8-1-A Throughout Building Structure
Grey CB & Mastic
ND N/A N/A
HA8-1-B Throughout Building Structure
Grey CB & Mastic
ND N/A N/A
HA8-2-A Throughout Building Structure
Grey CB & Mastic
ND N/A N/A
HA8-2-B Throughout Building Structure
Grey CB & Mastic
ND N/A N/A
HA9-1 Laundry Can Vase TSI Pipe Wrap
ND N/A N/A
HA9-2 Laundry Can Vase TSI Pipe Wrap
ND N/A N/A
HA9-3 Laundry Can Vase TSI Pipe Wrap
ND N/A N/A
HA10-1-A Accent (Hallway & Lobby)
Teal 12" VCT & Mastic
ND N/A N/A
September 24, 2024
Location
Material Description
Analytical Results
Category Estimated Quantity
Accent (Hallway & Lobby)
Accent (Hallway & Lobby)
Teal 12" VCT & Mastic
ND N/A N/A
Accent (Hallway & Lobby)
Accent (Hallway & Lobby)
Teal 12" VCT & Mastic
ND N/A N/A
Accent (Hallway & Lobby)
Accent (Hallway & Lobby)
Teal 12" VCT & Mastic
ND N/A N/A
HA11-1 2'x2' Pinhole CT
Laundry (250ft)
ND N/A N/A
HA11-2 2'x2' Pinhole CT
Laundry (250ft)
ND N/A N/A
4.2 Suspect or Assumed Asbestos-Containing Materials
Due to the inaccessibility or the destructive means that asbestos sampling requires, additional suspect ACMs may remain within the building hidden behind inaccessible areas that include, but are not limited to, sub-grade walls, structural members, topping slabs, sub-grade sealants, flooring located below underlayments, areas behind exterior walls, pipe trenches, and subsurface utilities, etc.
These areas were deemed inaccessible and were not assessed.
If these materials are discovered during construction activities, they should be presumed to contain asbestos and be treated as ACMs or be sampled immediately upon discovery and prior to disturbance for asbestos content by a certified asbestos inspector in accordance with 29 CFR 1926.1101.
4.3 Lead in Paint and Surface Coatings
Paint and surface coatings which contain detectable concentrations of lead considered “lead-containing paints” (LCP). Since OSHA has no specific action level for lead in paint, all paint on the site found to have a measurable concentration of lead should be assumed to be lead containing.
Work performed which may disturb lead-containing paint is regulated under OSHA as referenced under 29 CFR 1926.62.
Based on laboratory analysis of the paint chip samples collected and analyzed for lead content, lead was not detected above the method detection limit.
September 24, 2024
Summary Paint Chip Sampling Results
Sample ID Location Substrate Component Color Result
PC-1 Building Interior
Metal Sprinkler Pipes
Red <0.0042%
PC-2 Building Interior
Concrete Wall Beige <0.0074%
PC-3 Building Interior
Metal Door Brown <0.0040%
PC-4 Building Interior
Metal Door Frame Beige <0.0042%
PC-5 Building Interior
Concrete Wall Teal <0.0028%
PC-6 Building Interior
Concrete Wall Blue <0.0047%
PC-7 Building Interior
Concrete Wall Yellow <0.0060%
PC-8 Building Interior
Concrete Wall Pink <0.0071%
PC-9 Building Interior
Concrete Wall Purple <0.0042%
PC-10 Building Interior
Concrete Wall Green <0.0038%
PC-11 Building Interior
Concrete Wall Orange <0.0044%
PC-12 Building Interior
Metal Door Beige <0.0042%
PC-13 Building Interior
Metal Door Frame Beige <0.0029%
4.4 Visible Mold and Moisture
Below is a summary of our visual and olfactory observations collected as part of this evaluation.
4.4.1 Observations and Findings
Based on the visual assessment conducted on August 30, 2024, ECS presents a summary of observations and findings.
September 24, 2024
• ECS did not observe evidence of visible mold or moisture during our assessment. However, it was reported that ceiling tiles had been replaced throughout the building due to HVAC condensation.
• Mold odors were not observed in the building or attic space at the time of our assessment.
Representative photographs of the building are attached to this report.
5.0 RECOMMENDATIONS AND REGULATORY REQUIREMENTS
Based on our understanding of the purpose of the Asbestos, Lead Paint, and Mold Assessment, the results of laboratory analysis, and our findings and observations, ECS presents the following recommendations.
5.1 Asbestos-Containing Materials
None of the bulk samples submitted to Scientific Analytical Institute, Inc. were reported to contain detectable concentrations of asbestos. If additional suspect asbestos-containing materials are uncovered which were not accessible during this sampling event, it is recommended that these materials be sampled or tested immediately upon discovery for asbestos content by an asbestos inspector in accordance with 29 CFR 1926.1101.
5.2 Lead in Paint and Surface Coatings
Based on the results of paint chip sampling, lead was not detected in the samples above the laboratory detection limit.
Paint and surface coatings which contain detectable concentrations of lead considered “lead-containing paints” (LCP). Since OSHA has no specific action level for lead in paint, all paint on the site found to have a measurable concentration of lead should be assumed to be lead containing.
Work performed which may disturb lead-containing paint is regulated under OSHA as referenced under 29 CFR 1926.62.
5.3 Mold and Moisture
ECS did not observe evidence of visible mold or moisture during our assessment. However, it was reported that ceiling tiles had been replaced due to HVAC condensation as part of routine maintenance activities. ECS does not recommend additional assessment pertaining to mold at this time.
Note: The purpose of this survey was to evaluate areas where visible or apparent mold growth and/ or moisture intrusion has occurred and provide findings and recommendations for remedial work efforts. Identification and recommendation(s) for correction of all moisture intrusion concerns were outside of the scope of services for this work.
September 24, 2024
6.0 LIMITATIONS
The conclusions and recommendations presented within this report are based upon a reasonable level of assessment within normal bounds and standards of professional practice for a site in this particular geographic setting. ECS is not responsible or liable for the discovery and elimination of hazards that may potentially cause damage, accidents, or injuries.
The observations, conclusions, and recommendations pertaining to environmental conditions at the subject site are necessarily limited to conditions observed, and/or materials reviewed at the time this study was undertaken. No warranty, expressed or implied, is made with regard to the conclusions and recommendations presented within this report. This report is provided for the exclusive use of the client. This report is not intended to be used or relied upon in connection with other projects or by other unidentified third parties without the written consent of ECS and the client.
Our recommendations are in part based on federal, state, and local regulations and guidelines. ECS does not assume the responsibility of the person(s) in charge of the site, or otherwise undertake responsibility for reporting to any local, state, or federal public agencies, any conditions at the site that may present a potential danger to public health, safety, or the environment. Under this scope of services, ECS assumes no responsibility regarding any response actions initiated as a result of these findings. General compliance with regulations and response actions are the sole responsibility of the Client and should be conducted in accordance with local, state, and/or federal requirements.
September 24, 2024
Appendix I: Figures
Appendix II: Site Photographs
1 - View of front entrance to TT113.
2 - View of the back of the building.
ECS Project No. 49:23942
3 - View of the mechanical areas.
4 - View of the typical mechanical rooms
5 - View of the electrical room.
6 - View of the typical hallways.
7 - View of the kitchen.
8 - View of the nursery.
9 - View of the toddlers rooms.
10 - View of the staff lounge.
11 - View of storage closet.
12 - View of the laundry room.
13 - View of the conference room.
14 - View of the typical classrooms.
15 - View of the typical skylights.
16 - View of the attic space.
17 - View of the gypsum upper ceilings.
18 - View of the typical windows.
19 - View of the sheet vinyl in individual classrooms.
20 - View of the typical staff bathrooms.
Appendix III: Asbestos Bulk Sample Results
Bulk Asbestos Analysis By Polarized Light Microscopy EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10061850Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/11/2024
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
HA1-1
10061850_0001
White Foam TSI Sealant
None Detected 5% Cellulose 95% Other
Non-Fibrous
Ashed
White
Homogeneous
HA1-2
10061850_0002
White Foam TSI Sealant
None Detected 5% Cellulose 95% Other
Non-Fibrous
Ashed
White
Homogeneous
HA2-1
10061850_0003
Red Fire-Stop Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Red
Homogeneous
HA2-2
10061850_0004
Red Fire-Stop Caulk
None Detected 100% Other
Non-Fibrous
Ashed
Red
Homogeneous
HA3-1
10061850_0005
Drywall & Joint Compound
None Detected 5% Cellulose 95% Other
Non-Fibrous
Ashed
White, Gray
Homogeneous drywall: none detected, joint compound: none detected
HA3-2
10061850_0006
Drywall & Joint Compound
None Detected 5% Cellulose 95% Other
Non-Fibrous
Ashed
Gray, White
Homogeneous drywall: none detected, joint compound: none detected
HA4-1
10061850_0007
Drywall & Joint Compound
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
Gray, White
Homogeneous drywall: none detected, joint compound: none detected
HA4-2
10061850_0008
Drywall & Joint Compound
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
White, Gray
Homogeneous drywall: none detected, joint compound: none detected
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Kiersten Smith (31)
Analyst Approved Signatory
Page 1 of 4P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10061850Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/11/2024
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
HA5-1
10061850_0009
2x2 Smooth Ceiling Tiles
None Detected 70% Fiber Glass 30% Perlite
Fibrous
Dissolved
Yellow
Homogeneous
HA5-2
10061850_0010
2x2 Smooth Ceiling Tiles
None Detected 70% Fiber Glass 30% Perlite
Fibrous
Dissolved
Yellow
Homogeneous
HA6-1 - A
10061850_0011
Beige Sheet Vinyl
None Detected 5% 5%
Cellulose Fiber Glass
90% Other
Fibrous
Dissolved
Beige
Homogeneous sheet vinyl
HA6-1 - B
10061850_0024
Beige Sheet Vinyl
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
HA6-2 - A
10061850_0012
Beige Sheet Vinyl
None Detected 5% 5%
Fiber Glass Cellulose
90% Other
Fibrous
Dissolved
Beige
Homogeneous sheet vinyl
HA6-2 - B
10061850_0025
Beige Sheet Vinyl
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
HA7-1 - A
10061850_0013
Grey 12' VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous
VCT
HA7-1 - B
10061850_0026
Grey 12' VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Kiersten Smith (31)
Page 2 of 4P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10061850Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/11/2024
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
HA7-2 - A
10061850_0014
Grey 12' VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous
VCT
HA7-2 - B
10061850_0027
Grey 12' VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
HA8-1 - A
10061850_0015
Grey Cove Base and Mastic
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous cove base
HA8-1 - B
10061850_0028
Grey Cove Base and Mastic
None Detected 100% Other
Non-Fibrous
Ashed
Yellow
Homogeneous mastic
HA8-2 - A
10061850_0016
Grey Cove Base and Mastic
None Detected 100% Other
Non-Fibrous
Ashed
Gray
Homogeneous cove base
HA8-2 - B
10061850_0029
Grey Cove Base and Mastic
None Detected 100% Other
Non-Fibrous
Ashed
Yellow
Homogeneous mastic
HA9-1
10061850_0017
Canvas TSI Pipe Wrap
None Detected 20% Cellulose 80% Other
Fibrous
Ashed
White
Homogeneous
HA9-2
10061850_0018
Canvas TSI Pipe Wrap
None Detected 20% Cellulose 80% Other
Fibrous
Ashed
White
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Kiersten Smith (31)
Page 3 of 4P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10061850Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PLM
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/11/2024
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
HA9-3
10061850_0019
Canvas TSI Pipe Wrap
None Detected 20% Cellulose 80% Other
Fibrous
Ashed
White
Homogeneous
HA10-1 - A
10061850_0020
Teal 12" VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Blue, Green
Homogeneous
VCT
HA10-1 - B
10061850_0030
Teal 12" VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
HA10-2 - A
10061850_0021
Teal 12" VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Blue, Green
Homogeneous
VCT
HA10-2 - B
10061850_0031
Teal 12" VCT and Mastic
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
HA11-1
10061850_0022
2x2 Pinhole Ceiling Tiles
None Detected 70% Fiber Glass 30% Perlite
Fibrous
Dissolved
Gray
Homogeneous
HA11-2
10061850_0023
2x2 Pinhole Ceiling Tiles
None Detected 70% Fiber Glass 30% Perlite
Fibrous
Dissolved
Gray
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Kiersten Smith (31)
Page 4 of 4P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Client: ECS Southeast, LLC Contact: Braxton Dawson Address: 6714 Netherlands Drive
Wilmington, NC 28405 Phone: 910-899-1289 Fax: 910-686-9666 Email: bdawson@ecslimited.com cc:
Project: TT113 - Tarawa Terrace 11- CDC
Camp Lejeune, NC Client Notes:
Date Sampled: 9/3/2024 0:00 P.O. #. 49-23942 Date Submitted: 915/2024 0:00
Analysis: PLM Bulk w/ Positive Stop TurnAroundTlme: 72-hrTAT
Sample Number Notes
HA1-1
HA1-2
HA2-1
HA2-2
HA3-1 Comoosite HA3-2 Composite HA4-1 Comoosite HA4-2 Composite
HA5-1
HA5-2
HA6-1
HA6-2
HA7-1
HA7-2
HA8-1
HA8-2
HA9-1
HA9-2
HA9-3
HA10-1
HA10-2
HA11-1
HA11 -2
*Instructions:
Use Column •a• for your contact info
To See an Example Click the bottom Example Tab.
Enter samples between"<<" and">>" Begin Samples with a "<< "above the first sample and end with a ">>" below the last sample.
Only Enter your data on the first sheet "Sheet1 •
Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you to facilitate your reintegration of the report data.
Sample Description
White Foam TSI Sealant White Foam TSI Sealant Red Fire-Stop Caulk Red Fire-Stop Caulk Drvwall & Joint Comoound Drywall & Joint Compound Drvwall & Joint Comoound Drywall & Joint Compound 2x2 Smooth Ceilina Tiles 2x2 Smooth Ceiling Tiles Beiae Sheet Vinv1 Beige Sheet Vinvt Grey 12' VCT and Mastic Grev 12' VCT and Mastic Grey Cove Base and Mastic Grev Cove Base and Mastic Canvas TSI Pioe Wrao Canvas TSI Pioe Wrao Canvas TSI Pipe Wrap Teal 12" VCT and Mastic Teal 12" VCT and Mastic 2x2 Pinhole Ceilina Tiles 2x2 Pinhole Ceiling Tiles
Scientific • Analytical ~ I ns t itute , ,, 4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888
Fax: 336 .292.331 3 Email: /ab@sailab.com
!Location
Mechanical/ Electrical Rooms Mechanical/ Electrical Rooms Mechanical/ Electrical Rooms Mechanical/ Electrical Rooms Mechanical/ Electrical Rooms Mechanical/ Electrical Rooms UnnAr ceilinas/ Skv1iahts Uooer ceilings/ Skylights Ceilinas Throuahout Ceilings Throughout Bathrooms in Classrooms Bathrooms in Classrooms Primarv Floorina Throuahout Primary Flooring Throughout Classrooms and Hallwavs Classrooms and Hallways laundry Room Laundrv Room laundry Room Accent Halwavs and Lobby Accent Halwavs and Lobbv Laundry Rooms (250ft) Laundrv Rooms (250ft)
Accepted
Rejected dJ
\ Received By q l, < l O'te> o/'yv\
Appendix IV: Lead Laboratory Analytical Results
Analysis for Lead Concentration in Paint Chips by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Lab Order ID:Attn: 10061848Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PBP
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/12/2024
Sample ID
Lab Sample ID
Description
Lab Notes
Concentration (ppm)
Concentration (% by weight)
Mass (g)
PC-1
10061848_0001
Red Metal Sprinkler Pipes <420.0958 <0.0042%
PC-2
10061848_0002
Beige CMU Walls <740.0537 <0.0074%
PC-3
10061848_0003
Brown Metal Door Frames <40.0.0994 <0.0040%
PC-4
10061848_0004
Beige Metal Viewing Window Frames <420.0961 <0.0042%
PC-5
10061848_0005
Teal CMU Walls <280.0722 <0.0028%
PC-6
10061848_0006
Blue CMU Walls <470.0859 <0.0047%
PC-7
10061848_0007
Yellow CMU Walls <60.0.0662 <0.0060%
PC-8
10061848_0008
Pink CMU Walls <710.0564 <0.0071%
Disclaimer: Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 50ml sample is 4µg Total Pb).
Athena Summa (13)
Page 1 of 2L-F-021 r17 2/13/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Analysis for Lead Concentration in Paint Chips by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Lab Order ID:Attn: 10061848Customer: ECS Southeast, LLP 6714 Netherlands Dr Wilmington, NC 28405
Analysis:
Date Received:
Braxton Dawson
PBP
09/06/2024
Project: TT113 - Terawa Terrace II - CDC Camp Lejeune, NC
Date Reported: 09/12/2024
Sample ID
Lab Sample ID
Description
Lab Notes
Concentration (ppm)
Concentration (% by weight)
Mass (g)
PC-9
10061848_0009
Purple CMU Walls <420.0962 <0.0042%
PC-10
10061848_0010
Green CMU Walls <380.1060 <0.0038%
PC-11
10061848_0011
Orange CMU Walls <440.0916 <0.0044%
PC-12
10061848_0012
Beige Metal Doors <420.0950 <0.0042%
PC-13
10061848_0013
Beige Metal Door Frames <290.1359 <0.0029%
Disclaimer: Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with the samples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 50ml sample is 4µg Total Pb).
Athena Summa (13)
Page 2 of 2L-F-021 r17 2/13/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Client: ECS Southeast, LLP Contact: Braxton Dawson Address: 6714 Netherlands Drive
Wilmington, NC 28405 Mobile#: 910-899-1289 Fax: 910-686-9666 Email: bdawson@ecslimited.com cc:
Project: TT113 - Terawa Terrace II - CDC
Camp Lejeune, NC Client Notes:
Date Sampled: 9/3/2024 17:00 P.O.#. 49-23942 Date Submitted: 915/2024 12:00
Analysis: Paint Chips by Flame AA (PBP) TurnAroundTime: 3-day
Sample Number !Notes
PC-1
PC-2
PC-3
PC-4
PC-5
PC-6
PC-7
PC-8
PC-9
PC-10
PC-11
PC-12
PC-13
*Instructions:
Use Column •a• for your contact info
To See an Example Click the bottom Example Tab.
Enter samples between "<<"and">>" Begin Samples with a "<< "above the first sample and end with a ">>" below the last sample.
Only Enter your data on the first sheet "Sheet1 •
Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you to facilitate your reintegration of the report data.
!Sample Description
Red Metal Sorinkler Pioes Beige CMU Walls Brown Metal Door Frames Beiae Metal Viewina Window Frames Teal CMU Walls Blue CMU Walls Yellow CMU Walls Pink CMU Walls Purole CMU Walls Green CMU Walls Orange CMU Walls Beiae Metal Doors Beige Metal Door Frames
Lead Paint Chips
Scientific • Analytical ~ Institute ,, 4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888
Fax: 336.292.3313 Email: lab@sailab.com
Lactation
Fire Sorinklers Primary Wall Coating Classrooms/Hallways Classrooms/Hallways Hallway Accent Walls Hallway Accent Walls Hallway Accent Walls Hallway Accent Walls Hallway Accent Walls Hallway Accent Walls Hallway Accent Walls Emeraency Exits Emergency Exits
Accepted
Rejected r;/J
Received By
Appendix V: Certifications/ Licenses
| Title Page |
| Cover Letter |
| Executive Summary |
| 1.0 Site Description |
| 2.0 Purpose |
| 3.0 Methodology |
| 3.1 Asbestos-Containing Materials |
| 3.2 Lead in Paint and Surface Coatings |
| 3.3 Visible Mold |
| 4.0 Results |
| 4.1 Asbestos Sampling |
| 4.2 Suspect or Assumed Asbestos-Containing Materials |
| 4.3 Lead in Paint and Surface Coatings |
| 4.4 Visible Mold and Moisture |
| 4.4.1 Observations and Findings |
| 5.0 Recommendations and Regulatory Requirements |
| 5.1 Asbestos-Containing Materials |
| 5.2 Lead in Paint and Surface Coatings |
| 5.3 Mold and Moisture |
| 6.0 Limitations |
| Figures |
| Site Photographs |
| Asbestos Bulk Sample Results |
| Lead Laboratory Analytical Results |
| Certifications/Licenses |
File details come from the government source that posted it. Updated .