60042047 _Rev03.pdf

PDF 1 MB Posted

Attached to
Mechanical Repairs Bldg TT113 CDC
Solicitation number
N4008526R9010
Issued by

About this file

This is an interior finishes specification and floor plan document for mechanical building repairs at a Marine Corps Base facility (Building T113).

The document establishes general notes and finish standards for interior construction work, including requirements for wall paint finishes (PNT-1 standard unless otherwise indicated), hollow metal doors and frames (PNT-4), gypsum wallboard ceilings (PNT-5), resilient base flooring (RB-1), high-density polyethylene toilet partitions (HDPE-1), and interior wood doors (WD-1). Key specifications require that all finish items meet manufacturer installation requirements, with contractor responsibility for timely material ordering to prevent project delays. Thermostat locations must coordinate with mechanical drawings and be positioned at room corners or near light switches, not wall centers. All interior finishes in vertical exit ways, exit lobbies, and exit corridors must meet minimum Class A fire ratings. Electrical panels, access panels, and expansion joints require spray painting to match adjacent wall colors, with brush painting explicitly prohibited. Flooring transitions must comply with ABA guidelines and be centered under doorways. Telecommunications cabling requires marking with designated jack numbers during painting, with full retesting from faceplate to panel upon completion. The document includes a finish plan keyed to room designations (storage, staff areas, public restrooms, infant care rooms, laundry, kitchen, mechanical, and other support spaces) with associated closets and corridors. Revisions to the design are documented with approval dates of February 27, 2026 and March 31, 2026.

View the file

Other files

File Type Posted
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
Amend 0012.pdf PDF
M-202-T.pdf PDF
60042073_Rev03.pdf PDF
60042069_Rev03.pdf PDF
60042070_Rev03.pdf PDF
N4008523B0044 PPI Revision 03.pdf PDF
60042049 _Rev03.pdf PDF
60042066_Rev03.pdf PDF
Amend 0011.pdf PDF
Amend 0010 Enclosure 3 DWGS.pdf PDF
Amend 0010 Enclosure 1 DWG List.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0004.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0003.pdf PDF
Amend 0002 SECTION 01 31 50 TRANSFER AND ACCEPTANCE OF MILITARY REAL PROPERTY.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
N4008523B0044 Specs.pdf PDF
230044 SID Binder.pdf PDF
230044 Basis of Design.pdf PDF
N4008523B0044 Dwgs.pdf PDF
230044 Lead and Asbesto Report.pdf PDF
230044 APPD.pdf PDF
230044 Termite Inspection Report.pdf PDF
Mech MACC RFP.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FLOOR FINISH KEY

CPT-1

LVP-1

SC-1

NOT IN

SCOPE

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

PRETODDLER

CORRIDOR

TRAINING

SPECIALIST

STAFF TRAINING

OFFICE

DEPUTY

DIRECTOR

DIRECTOR

VESTIBULE

LOBBY

OFFICE

117A

INFANT

ADMIN

ADMIN

COMM/CCTV

STORAGE

STAFF RR

PUBLIC RR

INFANT

LAUNDRY

BREAK ROOM

JANITOR

INFANT

INFANT

INFANT

INFANT

SCULLERY

KITCHEN

ELETRICAL

MECHANICAL

DRY STORAGE

SPRINKLER

INFANT

PRESCHOOL

TODDLER

TODDLER

PRESCHOOL

PRESCHOOL

TODDLER

TODDLER

PRESCHOOL

TODDLER

CLOSET

102A

CLOSET

103A

CLOSET

104A

CLOSET

101A

CLOSET

105A

CLOSET

108A

CLOSET

107A

CLOSET

106A

CLOSET

119A

CLOSET

126A

CLOSET

134A

CLOSET

132A

CLOSET

142A

CLOSET

135A

CLOSET

133A

CLOSET

143A

CLOSET

146A

CLOSET

147A

CLOSET

150A

CLOSET

151A

CLOSET

149A

CLOSET

148A

CLOSET

145A

CLOSET

144A

CORRIDOR

CORRIDOR

RESTROOM

OFFICE

CORRIDOR

MECHANICAL

BUILDING

109F

MECHANICAL

YARD

109G

A B

C D

Fi le

P at h:

P rin t D at e:

E

SYM. DESCRIPTION DATE APP.

REVISIONS

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091 CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M

BF

A N

O

SPEC.

2 3 4 5 6

A B

C D

E

1 2 3 4 5 6

1008 GRANBY

STREET

NORFOLK, VA 23510

757.224.0489

W :\2

TT

M ec ha ni ca l R ep ai rs

\R ev it\

_T

T1

W

ID

_R

.rv t

3/

/2

:3 8:

P

M

I-111

DMR

JDK

JDK MECHANICAL REPAIRS

FINISH PLAN

60042047 N40085-23-B-0044

BUILDING TT113

4' 8' 16'0' 1/8" =1'-0"

GRAPHIC SCALE:

GENERAL NOTES

A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN

TO CONVEY COLOR, PATTERN, TEXTURE AND SALIENT

CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER

INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF

PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED

AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF

RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND

APPROVED BY THE CONTRACTING OFFICER.

B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO AVOID

DELAYS.

C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL

DRAWINGS AND CONSTRUCTION MANAGER. INSTALL

THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT

SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER

OF A WALL.

D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM CLASS

A RATING.

E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.

PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE.

G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.

FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST

BE CENTERED UNDER DOOR.

H. CONTRACTOR MUST MARK/TAPE ALL CABLES WITH THEIR

DESIGNATED JACK NUMBER WHEN FACEPLATES ARE

REMOVED FOR PAINTING. ALL CABLING IS REQUIRED TO BE

RETESTED (PER 27 10 00) FROM FACEPLATE TO PANEL.

I. ALL TELECOM MUST BE COVERED WHEN THE COMM/CCTV

ROOM IS PAINTED.

J. BACKBOARD MUST NOT BE PAINTED IN THE COMM/CCTV

ROOM.

K. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1).

L. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE

INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES

TO BE PAINTED (PNT-4). ALL GWB CEILINGS TO BE PAINTED

(PNT-5).

M. ALL TOILET PARTITION TO BE HDPE FINISH (HDPE-1).

N. ALL INTERIOR WOOD DOORS TO BE (WD-1).

O. SEE I-601 & I-602 FOR ROOM FINISH SCHEDULE AND FINISH

LEGEND.

P. "-" DESIGNATES "NO FINISH" OR "UNFINISHED".

SCALE: 1/8" = 1'-0"A1 FINISH PLAN

I G

IV

R

FOHT

I

NO

M N

EW

A

OM

L

C

C

A

Cert. 001152

JAMIE D. KISSEL RER

T

IFIED

INTERIOR DES

IG

N E No.

1 PPI #10 02/27/26

3 PPI #29 03/31/26

SCALE: 1/8" = 1'-0"A2 FINISH PLAN - MECHANICAL BLDG

File details come from the government source that posted it. Updated .