60042047 _Rev03.pdf
PDF 1 MB Posted
- Attached to
- Mechanical Repairs Bldg TT113 CDC
- Solicitation number
- N4008526R9010
About this file
This is an interior finishes specification and floor plan document for mechanical building repairs at a Marine Corps Base facility (Building T113).
The document establishes general notes and finish standards for interior construction work, including requirements for wall paint finishes (PNT-1 standard unless otherwise indicated), hollow metal doors and frames (PNT-4), gypsum wallboard ceilings (PNT-5), resilient base flooring (RB-1), high-density polyethylene toilet partitions (HDPE-1), and interior wood doors (WD-1). Key specifications require that all finish items meet manufacturer installation requirements, with contractor responsibility for timely material ordering to prevent project delays. Thermostat locations must coordinate with mechanical drawings and be positioned at room corners or near light switches, not wall centers. All interior finishes in vertical exit ways, exit lobbies, and exit corridors must meet minimum Class A fire ratings. Electrical panels, access panels, and expansion joints require spray painting to match adjacent wall colors, with brush painting explicitly prohibited. Flooring transitions must comply with ABA guidelines and be centered under doorways. Telecommunications cabling requires marking with designated jack numbers during painting, with full retesting from faceplate to panel upon completion. The document includes a finish plan keyed to room designations (storage, staff areas, public restrooms, infant care rooms, laundry, kitchen, mechanical, and other support spaces) with associated closets and corridors. Revisions to the design are documented with approval dates of February 27, 2026 and March 31, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| Amend 0012.pdf | ||
| M-202-T.pdf | ||
| 60042073_Rev03.pdf | ||
| 60042069_Rev03.pdf | ||
| 60042070_Rev03.pdf | ||
| N4008523B0044 PPI Revision 03.pdf | ||
| 60042049 _Rev03.pdf | ||
| 60042066_Rev03.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010 Enclosure 3 DWGS.pdf | ||
| Amend 0010 Enclosure 1 DWG List.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0004.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002 SECTION 01 31 50 TRANSFER AND ACCEPTANCE OF MILITARY REAL PROPERTY.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| N4008523B0044 Specs.pdf | ||
| 230044 SID Binder.pdf | ||
| 230044 Basis of Design.pdf | ||
| N4008523B0044 Dwgs.pdf | ||
| 230044 Lead and Asbesto Report.pdf | ||
| 230044 APPD.pdf | ||
| 230044 Termite Inspection Report.pdf | ||
| Mech MACC RFP.pdf |
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLOOR FINISH KEY
CPT-1
LVP-1
SC-1
NOT IN
SCOPE
PRETODDLER
PRETODDLER
PRETODDLER
PRETODDLER
PRETODDLER
PRETODDLER
PRETODDLER
PRETODDLER
CORRIDOR
TRAINING
SPECIALIST
STAFF TRAINING
OFFICE
DEPUTY
DIRECTOR
DIRECTOR
VESTIBULE
LOBBY
OFFICE
117A
INFANT
ADMIN
ADMIN
COMM/CCTV
STORAGE
STAFF RR
PUBLIC RR
INFANT
LAUNDRY
BREAK ROOM
JANITOR
INFANT
INFANT
INFANT
INFANT
SCULLERY
KITCHEN
ELETRICAL
MECHANICAL
DRY STORAGE
SPRINKLER
INFANT
PRESCHOOL
TODDLER
TODDLER
PRESCHOOL
PRESCHOOL
TODDLER
TODDLER
PRESCHOOL
TODDLER
CLOSET
102A
CLOSET
103A
CLOSET
104A
CLOSET
101A
CLOSET
105A
CLOSET
108A
CLOSET
107A
CLOSET
106A
CLOSET
119A
CLOSET
126A
CLOSET
134A
CLOSET
132A
CLOSET
142A
CLOSET
135A
CLOSET
133A
CLOSET
143A
CLOSET
146A
CLOSET
147A
CLOSET
150A
CLOSET
151A
CLOSET
149A
CLOSET
148A
CLOSET
145A
CLOSET
144A
CORRIDOR
CORRIDOR
RESTROOM
OFFICE
CORRIDOR
MECHANICAL
BUILDING
109F
MECHANICAL
YARD
109G
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY
STREET
NORFOLK, VA 23510
757.224.0489
W :\2
TT
M ec ha ni ca l R ep ai rs
\R ev it\
_T
T1
W
ID
_R
.rv t
3/
/2
:3 8:
P
M
I-111
DMR
JDK
JDK MECHANICAL REPAIRS
FINISH PLAN
60042047 N40085-23-B-0044
BUILDING TT113
4' 8' 16'0' 1/8" =1'-0"
GRAPHIC SCALE:
GENERAL NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN
TO CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO AVOID
DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER
OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM CLASS
A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS.
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE.
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. CONTRACTOR MUST MARK/TAPE ALL CABLES WITH THEIR
DESIGNATED JACK NUMBER WHEN FACEPLATES ARE
REMOVED FOR PAINTING. ALL CABLING IS REQUIRED TO BE
RETESTED (PER 27 10 00) FROM FACEPLATE TO PANEL.
I. ALL TELECOM MUST BE COVERED WHEN THE COMM/CCTV
ROOM IS PAINTED.
J. BACKBOARD MUST NOT BE PAINTED IN THE COMM/CCTV
ROOM.
K. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1).
L. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES
TO BE PAINTED (PNT-4). ALL GWB CEILINGS TO BE PAINTED
(PNT-5).
M. ALL TOILET PARTITION TO BE HDPE FINISH (HDPE-1).
N. ALL INTERIOR WOOD DOORS TO BE (WD-1).
O. SEE I-601 & I-602 FOR ROOM FINISH SCHEDULE AND FINISH
LEGEND.
P. "-" DESIGNATES "NO FINISH" OR "UNFINISHED".
SCALE: 1/8" = 1'-0"A1 FINISH PLAN
I G
IV
R
FOHT
I
NO
M N
EW
A
OM
L
C
C
A
Cert. 001152
JAMIE D. KISSEL RER
T
IFIED
INTERIOR DES
IG
N E No.
1 PPI #10 02/27/26
3 PPI #29 03/31/26
SCALE: 1/8" = 1'-0"A2 FINISH PLAN - MECHANICAL BLDG
File details come from the government source that posted it. Updated .