60042049 _Rev03.pdf
PDF 171 KB Posted
- Attached to
- Mechanical Repairs Bldg TT113 CDC
- Solicitation number
- N4008526R9010
About this file
This document is an architectural finish schedule for mechanical repairs to Building T113 at a Marine Corps Base. The schedule specifies interior finishes across multiple rooms, detailing floor finishes, base finishes, wall finishes, and ceiling finishes for each designated space.
The general notes establish critical requirements for finish execution and material selection. Finishes indicated serve as the approved basis of design to convey color, pattern, and texture, with manufacturer information provided as examples only. Products from other manufacturers meeting the specified criteria are acceptable if reviewed by the Interior Designer of Record (IDOR) and NAVFAC Interior Designer and approved by the Contracting Officer. The contractor is responsible for ordering all materials with sufficient lead time to prevent project delays. Key installation requirements include thermostat placement near room corners or light switches rather than wall centers, minimum Class A fire ratings for all interior finishes in vertical exit ways and exit corridors, spray painting (not brush painting) of electrical panels and expansion joints to match adjacent walls, ABA-compliant flooring transitions centered under doorways, and adherence to all manufacturer installation specifications. Additional requirements address telecom cable marking and retesting during painting operations, protection of telecom equipment during communications room painting, and prohibition of backboard painting in the communications/CCTV room. Standard finishes include resilient base (RB-1) on all applicable areas, paint finish (PNT-1) on walls, (PNT-4) on hollow metal doors and frames, and (PNT-5) on gypsum wallboard ceilings, with carpet tile installation specified in vertical ashlar pattern and windows receiving single-layer roller shades.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| M-202-T.pdf | ||
| Amend 0012.pdf | ||
| 60042073_Rev03.pdf | ||
| 60042066_Rev03.pdf | ||
| Amend 0011.pdf | ||
| 60042047 _Rev03.pdf | ||
| 60042070_Rev03.pdf | ||
| N4008523B0044 PPI Revision 03.pdf | ||
| 60042069_Rev03.pdf | ||
| Amend 0010.pdf | ||
| Amend 0010 Enclosure 3 DWGS.pdf | ||
| Amend 0010 Enclosure 1 DWG List.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0004.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002 SECTION 01 31 50 TRANSFER AND ACCEPTANCE OF MILITARY REAL PROPERTY.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| N4008523B0044 Specs.pdf | ||
| 230044 SID Binder.pdf | ||
| 230044 Basis of Design.pdf | ||
| 230044 Termite Inspection Report.pdf | ||
| Mech MACC RFP.pdf | ||
| 230044 Lead and Asbesto Report.pdf | ||
| 230044 APPD.pdf | ||
| N4008523B0044 Dwgs.pdf |
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A B
C D
Fi le
P at h:
P rin t D at e:
E
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091 CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M
BF
A N
O
SPEC.
2 3 4 5 6
A B
C D
E
1 2 3 4 5 6
1008 GRANBY
STREET
NORFOLK, VA 23510
757.224.0489
W :\2
TT
M ec ha ni ca l R ep ai rs
\R ev it\
_T
T1
W
ID
_R
.rv t
3/
/2
:3 9:
P
M
I-601
DMR
JDK
JDK MECHANICAL REPAIRS
SCHEDULES & LEGENDS
60042049 N40085-23-B-0044
BUILDING TT113
ROOM FINISH SCHEDULE
ROOM
FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH NOTESNO. NAME
101 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
101A CLOSET LVP-1 RB-1 PNT-1 ACT-1
102 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
102A CLOSET LVP-1 RB-1 PNT-1 ACT-1
103 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
103A CLOSET LVP-1 RB-1 PNT-1 ACT-1
104 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
104A CLOSET LVP-1 RB-1 PNT-1 ACT-1
105 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
105A CLOSET LVP-1 RB-1 PNT-1 ACT-1
106 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
106A CLOSET LVP-1 RB-1 PNT-1 ACT-1
107 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
107A CLOSET LVP-1 RB-1 PNT-1 ACT-1
108 PRETODDLER LVP-1 RB-1 PNT-1 ACT-1 2
108A CLOSET LVP-1 RB-1 PNT-1 ACT-1
109 CORRIDOR LVP-1 RB-1 PNT-1 ACT-1
109F MECHANICAL BUILDING SC-1 - PNT-1 -
109G MECHANICAL YARD SC-1 - - -
110 TRAINING SPECIALIST CPT-1 RB-1 PNT-1 ACT-1 1
111 STAFF TRAINING CPT-1 RB-1 PNT-1 ACT-1 1
112 OFFICE CPT-1 RB-1 PNT-1 ACT-1 1
113 DEPUTY DIRECTOR CPT-1 RB-1 PNT-1 ACT-1 1,2
114 DIRECTOR CPT-1 RB-1 PNT-1 ACT-1 1,2
115 VESTIBULE LVP-1 RB-1 PNT-1 ACT-1
116 LOBBY LVP-1 RB-1 PNT-1 ACT-1
117 OFFICE LVP-1 RB-1 PNT-1 ACT-1
117A OFFICE LVP-1 RB-1 PNT-1 ACT-1
118 CORRIDOR LVP-1 RB-1 PNT-1 ACT-1
119 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
119A CLOSET LVP-1 RB-1 PNT-1 ACT-1
120 ADMIN CPT-1 RB-1 PNT-1 ACT-1 1
121 ADMIN CPT-1 RB-1 PNT-1 ACT-1 1
122 COMM/CCTV EXISTING EXISTING EXISTING EXISTING
123 STORAGE LVP-1 RB-1 PNT-1 ACT-1
124 STAFF RR EXISTING - EXISTING PNT-5
125 PUBLIC RR EXISTING - EXISTING PNT-5
126 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
126A CLOSET LVP-1 RB-1 PNT-1 ACT-1
128 CORRIDOR LVP-1 RB-1 PNT-1 ACT-1
129 LAUNDRY LVP-1 RB-1 PNT-1 ACT-1
130 BREAK ROOM LVP-1 RB-1 PNT-1 ACT-1
131 JANITOR EXISTING - EXISTING PNT-5
132 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
132A CLOSET LVP-1 RB-1 PNT-1 ACT-1
133 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
133A CLOSET LVP-1 RB-1 PNT-1 ACT-1
134 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
134A CLOSET LVP-1 RB-1 PNT-1 ACT-1
135 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
135A CLOSET LVP-1 RB-1 PNT-1 ACT-1
136 SCULLERY EXISTING - PNT-1 PNT-5
137 KITCHEN EXISTING - PNT-1 PNT-5
138 ELETRICAL SC-1 - PNT-1 PNT-5
139 MECHANICAL SC-1 - PNT-1 PNT-5
140 DRY STORAGE EXISTING - PNT-1 PNT-5
141 SPRINKLER SC-1 - PNT-1 PNT-5
142 INFANT LVP-1 RB-1 PNT-1 ACT-1 2
142A CLOSET LVP-1 RB-1 PNT-1 ACT-1
143 PRESCHOOL LVP-1 RB-1 PNT-1 ACT-1 2
143A CLOSET LVP-1 RB-1 PNT-1 ACT-1
144 TODDLER LVP-1 RB-1 PNT-1 ACT-1 2
144A CLOSET LVP-1 RB-1 PNT-1 ACT-1
145 TODDLER LVP-1 RB-1 PNT-1 ACT-1 2
145A CLOSET LVP-1 RB-1 PNT-1 ACT-1
146 PRESCHOOL LVP-1 RB-1 PNT-1 ACT-1 2
146A CLOSET LVP-1 RB-1 PNT-1 ACT-1
147 PRESCHOOL LVP-1 RB-1 PNT-1 ACT-1 2
147A CLOSET LVP-1 RB-1 PNT-1 ACT-1
148 TODDLER LVP-1 RB-1 PNT-1 ACT-1 2
148A CLOSET LVP-1 RB-1 PNT-1 ACT-1
149 TODDLER LVP-1 RB-1 PNT-1 ACT-1 2
149A CLOSET LVP-1 RB-1 PNT-1 ACT-1
150 PRESCHOOL LVP-1 RB-1 PNT-1 ACT-1 2
150A CLOSET LVP-1 RB-1 PNT-1 ACT-1
151 TODDLER LVP-1 RB-1 PNT-1 ACT-1 2
151A CLOSET LVP-1 RB-1 PNT-1 ACT-1
152 RESTROOM EXISTING - EXISTING PNT-5
153 CORRIDOR LVP-1 RB-1 PNT-1 ACT-1
GENERAL NOTES
A. FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN
TO CONVEY COLOR, PATTERN, TEXTURE AND SALIENT
CHARACTERISTICS ONLY. THE LISTING OF MANUFACTURER
INFORMATION IS NOT INTENDED TO LIMIT THE SELECTION OF
PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED
AND MUST BE REVIEWED BY THE INTERIOR DESIGNER OF
RECORD (IDOR) AND THE NAVFAC INTERIOR DESIGNER AND
APPROVED BY THE CONTRACTING OFFICER.
B. FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO
ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S
RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO AVOID
DELAYS.
C. COORDINATE THERMOSTAT LOCATIONS WITH MECHANICAL
DRAWINGS AND CONSTRUCTION MANAGER. INSTALL
THERMOSTATS NEAR A CORNER OF THE ROOM OR BY LIGHT
SWITCHES. DO NOT INSTALL THERMOSTATS IN THE CENTER
OF A WALL.
D. ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT
LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM CLASS
A RATING.
E. ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURER'S INSTALLATION REQUIREMENTS.
F. SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND
EXPANSION JOINTS TO MATCH THE ADJACENT WALL COLOR.
PANELS PAINTED BY BRUSH ARE NOT ACCEPTABLE.
G. ALL FLOORING TRANSITIONS MUST MEET ABA GUIDELINES.
FLOORING TRANSITIONS OCCURRING UNDER DOORS MUST
BE CENTERED UNDER DOOR.
H. CONTRACTOR MUST MARK/TAPE ALL CABLES WITH THEIR
DESIGNATED JACK NUMBER WHEN FACEPLATES ARE
REMOVED FOR PAINTING. ALL CABLING IS REQUIRED TO BE
RETESTED (PER 27 10 00) FROM FACEPLATE TO PANEL.
I. ALL TELECOM MUST BE COVERED WHEN THE COMM/CCTV
ROOM IS PAINTED.
J. BACKBOARD MUST NOT BE PAINTED IN THE COMM/CCTV
ROOM.
K. ALL AREAS TO RECEIVE RESILIENT BASE (RB-1).
L. ALL WALLS TO BE PAINTED (PNT-1) UNLESS OTHERWISE
INDICATED. ALL HOLLOW METAL DOORS AND DOOR FRAMES
TO BE PAINTED (PNT-4). ALL GWB CEILINGS TO BE PAINTED
(PNT-5).
M. ALL TOILET PARTITION TO BE HDPE FINISH (HDPE-1).
N. ALL INTERIOR WOOD DOORS TO BE (WD-1).
O. SEE I-601 & I-602 FOR ROOM FINISH SCHEDULE AND FINISH
LEGEND.
P. "-" DESIGNATES "NO FINISH" OR "UNFINISHED".
FINISH SCHEDULE KEY NOTES
1. CARPET TILE INSTALLATION TO BE VERTICAL ASHLAR
PATTERN.
2. WINDOWS TO RECEIVE SINGLE LAYER ROLLER SHADE