1701820dwg_Revision_0001_A2-A3-Site.pdf

PDF 19 MB Posted

Attached to
Design-Bid-Build (DBB) SOF Marine Raider Facilities Complex, Marine Corps Base (MCB) Camp Lejeune, North Carolina
Solicitation number
N4008526R0138
Issued by

About this file

This document is a comprehensive set of architectural and engineering drawings for the MARSOC SOF Marine Battalion Company Team Facilities (P-1550) project at Camp Lejeune, North Carolina.

The project encompasses the design of multiple building areas (A, B, C, D, E, and F) featuring team operational spaces, administrative offices, training facilities, storage areas, laundry facilities, maintenance areas, and support infrastructure. Key design elements include flexible team work areas, individual cage storage for equipment, open storage sections, designated mechanical and electrical rooms, and appropriate toilet/sanitary facilities. The drawings specify construction standards including metal stud framing, gypsum board finishes, brick veneer exterior cladding with split-face CMU accents, standing seam metal roofing, and aluminum window systems. Interior finishes include porcelain tile in wet areas, finished concrete floors in operational spaces, and acoustic ceiling systems. Mechanical systems detailed include HVAC handling units with cooling/heating capabilities, hot water heaters, plumbing with floor drains and traps, and fire suppression systems. Electrical infrastructure consists of panelboards, distribution circuits, lighting fixtures, and emergency systems. The drawings also address site logistics including telecommunications ductbank systems, utility routing, drainage design, parking areas, and monument relocation documentation. All construction is designed to comply with Department of Defense facility standards, accessibility requirements, and applicable building codes, with detailed specifications for seismic bracing, moisture barriers, and structural support systems throughout.

View the file

Other files

File Type Posted
AMENDMENT 0011 - N4008526R0138.pdf PDF
P1550 PPI RESPONSES 5.pdf PDF
AMENDMENT 0010 - N4008526R0138.pdf PDF
AMENDMENT 0009 - N4008526R0138.pdf PDF
AMENDMENT 0008 - N4008526R0138.pdf PDF
P1550 PPI RESPONSES 3.pdf PDF
WD NC20260010.pdf PDF
AMENDMENT 0006- 26R0138.pdf PDF
1701820 Continuation Sheet_0004.pdf PDF
1701820dwg_Revision_0004_A2.pdf PDF
P1550 PPI RESPONSES 3.pdf PDF
AMENDMENT 0005 - 26R0138.pdf PDF
13 34 19.pdf PDF
1701820 Continuation Sheet.docx DOCX document
AMENDMENT 0004 - 26R0138.pdf PDF
1701820dwg_Revision_0003_A2.pdf PDF
AMENDMENT 0003 - 26R0138.pdf PDF
1701820dwg01of01.pdf PDF
1701820 Continuation Sheet .docx DOCX document
P1550 PPI RESPONSES 2.pdf PDF
1701820 Continuation Sheet 2026.06.04.docx DOCX document
26 56 00.pdf PDF
03 30 00.pdf PDF
P1550 Site Visit Sign-in Sheet.pdf PDF
26 32 15.00.pdf PDF
08 33 23.pdf PDF
AMENDMENT 0002 - 26R0138.pdf PDF
Construction Site Visit MARSOC Access List.xlsx XLSX spreadsheet
Attachment I - DOD-CUI_Non-Disclosure Agreement.pdf PDF
Attachment C - Price Proposal Form REVISED.docx DOCX document
AMENDMENT 0001 - 26R0138.pdf PDF
P1550 PPI RESPONSES 1.pdf PDF
1701820 A1 - FINAL_1.pdf PDF
1701820 A3 - FINAL_3.pdf PDF
Attachment F - Historical Small Business Utilization.docx DOCX document
1701820 SITE - FINAL_v2_4 Flattened 2 of 2.pdf PDF
1701820 SPC -FINAL.pdf PDF
Attachment G - SPCD.docx DOCX document
Attachment D - Construction and Design Experience Project Data Sheet.docx DOCX document
1701820 A2 - FINAL_2.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment H -Small Business Subcontracting Plan.docx DOCX document
Solicitation - N4008526R0138.pdf PDF
Attachment C - Price Proposal Form.docx DOCX document
Attachment A - Pre-Proposal Inquiry (PPI) Log.xlsx XLSX spreadsheet
1701820 SITE - FINAL_v2_4 Flattened 1 of 2.pdf PDF
Attachment E - Past Performance Questionnaire.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AREA A

AREA B

AREA C AREA E

AREA D AREA F

65432

C.8

D

D.6

D.3

E

G

F

D3

A-301

D3

A-301

C3

A-303

C3

A-303

2A

1A

6A

5A

4A

7A

8A

0A

6A

0A

9A

174A

173A

2A

9A

3A

7A

1A

5A

8A

153A

A-405 D1

A1

F

F

D1

D1

D1

D1

D1 D1

A1

F

F

A1

A1

A1

A1

A1

A1

A1

A1 A1

A1

A1A1

A1A1A1

A1 A1

D1

A1A1

A1

A1

A1

A1

A1 A1

D1

A1

A1

A1A1

D1

A1

A1

A1A1

A1

A1

A1

A2 / A-102

A2

A-

F

A-508 A5

A-508 A5

A-5

B

B

A-5 A-5 A-5 A-5

1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND

2. REFERENCE SHEET A-501 FOR WALL TYPES

3. REFERENCE SHEET A-601 FOR DOOR AND FRAME SCHEDULE

4. REFERENCE SHEET A-605 FOR WINDOW SCHEDULE

5. REFERENCE INTERIOR DESIGN DRAWINGS FOR FINISH SCHEDULE

6. REFERENCE INTERIORS DRAWINGS FOR CASEWORK DIMENSIONS AND DETAILS

7. REFERENCE THE LIFE SAFETY DRAWINGS FOR LOCATIONS OF RATED WALLS

AND SMOKE PARTITIONS

8. DIMENSIONS ARE TAKEN FROM FACE OF METAL STUD AND FACE OF CMU

9. DIMENSIONS TO OPENINGS ARE SHOWN TO CENTER OF OPENING AT METAL

STUDS AND EXTERIOR OF OPENINGS AT CMU WALLS

10. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS ALL

ATTACHED FIXTURES PER MANUFACTURER'S RECOMMENDATIONS

11. PROVIDE STEEL STUD BACKING FOR ALL TV BRACKETS AS SHOWN ON AUDIO

VISUAL DRAWINGS

12. FOR ELECTRICAL BOXES AT STC WALLS, OFFSET ON STUD SPACE AND SEAL

OPENINGS THROUGH PARTITIONS

13. PROVIDE FULL HEIGHT STAINLESS STEEL CORNER GUARDS AT EXPOSED

CORNERS OF GYPSUM PARTITIONS

14. PROVIDE FIRE RATED PLYWOOD BACKBOARD AT COMM ROOMS

15. FOR LOUVERS, WINDOWS AND STOREFRONT TYPES SEE SHEET A-60X

16. PROVIDE HEAVY DUTY IMPACT RESISTANT GYPSUM BOARD AT THE FOLLOWING

ROOMS TO 12'-0" MINIMUM: TEAM STAGING/STORAGE, COMPANY STORAGE,

INDIVIDUAL ISSUE CAGE STORAGE, LAUNDRY, ELECTRICAL CLOSET, ENTRY

VESTIBULE, LOBBY, AND CORRIDOR

LOW PROFILE RAISED ACCESS FLOORING SYSTEM

6'-0" x 10'-0" RECESSED PAN FLOOR MAT

3-3/4" x 5-1/4" DOWNSPOUT TO STORM DRAIN

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C

F ile

P rin t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

0:

:5

A M

F

LO

O R

P

LA

N

A R

E A

B

A-103

1701820

FINAL SUBMITTAL

12903479

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

SCALE: 1/8" = 1'-0"

A2

FLOOR PLAN - AREA B

KEY PLAN

SCALE 1" = 60'

GENERAL CONSTRUCTION NOTES

CONSTRUCTION KEYNOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

James E. Donahue, R.A.

AREA C AREA E

AREA D AREA F

1514131211

C.8

D

D.6

D.3

E

G

F

D3

A-303

D3

A-303

112A

111A

3A

6A

5A

8A

4A

0A

9A

4A

3A

128A

7A

1A

9A

5A

2A

6A

127A

130A

0A

130B

142A

104B

A-405 D1

A2 / A-106

A2

A-

F

F

D1

A1

A1

A-508 A5

A-508 A5

A-5

B

B

A-5 A-5 A-5 A-5

1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND

2. REFERENCE SHEET A-501 FOR WALL TYPES

3. REFERENCE SHEET A-601 FOR DOOR AND FRAME SCHEDULE

4. REFERENCE SHEET A-605 FOR WINDOW SCHEDULE

5. REFERENCE INTERIOR DESIGN DRAWINGS FOR FINISH SCHEDULE

6. REFERENCE INTERIORS DRAWINGS FOR CASEWORK DIMENSIONS AND DETAILS

7. REFERENCE THE LIFE SAFETY DRAWINGS FOR LOCATIONS OF RATED WALLS

AND SMOKE PARTITIONS

8. DIMENSIONS ARE TAKEN FROM FACE OF METAL STUD AND FACE OF CMU

9. DIMENSIONS TO OPENINGS ARE SHOWN TO CENTER OF OPENING AT METAL

STUDS AND EXTERIOR OF OPENINGS AT CMU WALLS

10. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS ALL

ATTACHED FIXTURES PER MANUFACTURER'S RECOMMENDATIONS

11. PROVIDE STEEL STUD BACKING FOR ALL TV BRACKETS AS SHOWN ON AUDIO

VISUAL DRAWINGS

12. FOR ELECTRICAL BOXES AT STC WALLS, OFFSET ON STUD SPACE AND SEAL

OPENINGS THROUGH PARTITIONS

13. PROVIDE FULL HEIGHT STAINLESS STEEL CORNER GUARDS AT EXPOSED

CORNERS OF GYPSUM PARTITIONS

14. PROVIDE FIRE RATED PLYWOOD BACKBOARD AT COMM ROOMS

15. FOR LOUVERS, WINDOWS AND STOREFRONT TYPES SEE SHEET A-60X

16. PROVIDE HEAVY DUTY IMPACT RESISTANT GYPSUM BOARD AT THE FOLLOWING

ROOMS TO 12'-0" MINIMUM: TEAM STAGING/STORAGE, COMPANY STORAGE,

INDIVIDUAL ISSUE CAGE STORAGE, LAUNDRY, ELECTRICAL CLOSET, ENTRY

VESTIBULE, LOBBY, AND CORRIDOR

LOW PROFILE RAISED ACCESS FLOORING SYSTEM

6'-0" x 10'-0" RECESSED PAN FLOOR MAT

3-3/4" x 5-1/4" DOWNSPOUT TO STORM DRAIN

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

0:

:5

A M

F

LO

O R

P

LA

N

A R

E A

F

A-107

1701820

FINAL SUBMITTAL

12903483

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

SCALE: 1/8" = 1'-0"

A2

FLOOR PLAN - AREA F

KEY PLAN

SCALE 1" = 60'

GENERAL CONSTRUCTION NOTES

CONSTRUCTION KEYNOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

AREA C AREA E

AREA D AREA F

6 5 4 3 28 7

D3

A-301

D3

A-301

C3

A-301

C3

A-301

C3

A-302

C3

A-302

8'-0"

2'-0"

14'-0"14'-0"

2'-0"

14'-0"14'-0"

2'-0"

14'-0"14'-0"

2'-0"

14'-0"14'-0"

2'-0"

14'-9"16'-0"12'-11"22'-4"

CJ CJ CJ CJCJCJCJCJCJCJCJCJ

C3 /A

-2

TYP TYP

BA

13'-0" 20'-0" 13'-0 5/8"

CJ CJ

B A

CJCJ

13'-0" 20'-0" 13'-0"

WATERTABLE; SPLIT FACE CMU VENEER

SPLIT FACE CMU VENEER ACCENT BAND

BRICK VENEER

DOOR

OVERHEAD ROLL UP DOOR, COORDINATE HARDWARE

WITH SECURITY SYSTEMS

WINDOW

VERTICAL METAL PANEL

STANDING SEAM METAL ROOF

LOUVER. SEE MECHANICAL

8"x8" GUTTER

FASCIA

3 3/4" x 5 1/4" DOWNSPOUT TO STORM DRAIN

BRICK VENEER SOLDIER COURSE HEADER

MECHANICAL INTAKE/EXHAUST

COLUMN

EXTERIOR LIGHT FIXTURE. SEE ELECTRICAL

BRICK/CMU CONTROL JOINTS

GEAR WASH SINK

WALL CAP FOR DRYERS. SEE MECHANICAL

3 3/4" x 5 1/4" DOWNSPOUT TO STORM DRAIN

1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND

2. REFERENCE SHEET A-606 FOR EXTERIOR FINISHES SCHEDULE

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

0:

:0

A M

E X

T E

R

IO

R E

LE

V

A T

IO

N

S

A-202

1701820

FINAL SUBMITTAL

12903500

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

SCALE: 1" = 60'-0"

A5

KEY PLAN

SCALE: 1/8" = 1'-0"

D3

PARTIAL SOUTH ELEVATION

SCALE: 1/8" = 1'-0"

B3

PARTIAL EXTERIOR ELEVATION

SCALE: 1/8" = 1'-0"

B1

PARTIAL EXTERIOR ELEVATION

CONSTRUCTION KEYNOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

GENERAL CONSTRUCTION NOTES

1 1

138A

MAINTAIN 5'-0" DIAMETER

ACCESSIBLE CLEAR FLOOR

SPACE

MAINTAIN 2'-6" x 4'-0"

ACCESSIBLE CLEAR

FLOOR SPACE

FD

FD

FD

FD

C

B

138A

8 1/4" 13'-2 1/8"

13'-10 3/8"

±4 '-1

±4

'-5

±4 '-5

±4

'-5

±4 '-8

±4

'-1

1'- 0"

'-1

1/

2"

'-0

/8

4'-2" 8'-9" 4'-2"

17'-1"

3'- 0"

C

LE

AR

1'-

1/ 4"

±4 '-1

±4

'-5

±4 '-5

±4

'-5

±4 '-8

3'-

8"

1/ 4"

'-5

/8

5'- 0"

C

LE

AR

3'- 1"

4'-

3/ 8"

5'-

1/ 2"

'-5

1'-2 3/4"

2'-11 5/8" 5'-1 1/4" 3'-10 17/32"

5'-2"

3'-0 1/4"

FD

FD

FD

FD

A1 A1

D1

A1

B1

B1 A1

A1A1

A1

B1

B1

A3

D1 D1

9A

2'-4" 14'-9"

17'-1"

'-3

/4

1'-8 7/8" 4'-1 3/8"

8'-1"

5'-3"

2'- 8"

3'- 8"

5'-

1/ 4"

4'- 1"

6'- 0"

8'-6"

3'- 8"

FD

A3

A3

D1

D1

A1

A1

A1

A3B1

D1

D1

A1

D1

D1

D1

9A

MAINTAIN A 5'-0"

DIAMETER ACCESSIBLE

CLEAR FLOOR SPACE

MAINTAIN 2'-6" x 4'-0"

ACCESSIBLE CLEAR

FLOOR SPACE

FD

AREA A

AREA B

AREA C AREA E

AREA D AREA F

1. FOR SYMBOL LEGEND, SEE SHEET A-001

2. PROVIDE COAT HOOKS ON THE BACK OF ALL TOILET PARTITION DOOR

3. SEE FINISH SCHEDULE ON SHEETS I-601 AND I-602

4. PROVIDE CEMENTITIOUS BOARD AT ALL SHOWER STALLS. PROVIDE GLASS MATT WATER

RESISTIVE BACKING BOARD AS SUBSTRATE TO WALL TILE. PROVIDE MOISTURE RESISTANT

GYPSUM BOARD AT THE FOLLOWING WALL AND CEILINGS THAT DO NOT RECEIVE TILE:

MEN'S TOILET, WOMEN'S TOILET UNISEX TOILET, CO TOILET.

5. PROVIDE SINGLE BASE COURSE FULLY GROUTED 6" CMU AT ALL WALLS WITHIN

DEPRESSED SLAB AREAS - SEE STRUCTURAL FOUNDATION PLAN FOR LOCATIONS AND

DEPTH OF DEPRESSED SLABS.

6. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS WALL ATTACHED

FIXTURES/ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS

7. REFER TO XX/A-XXX FOR CERAMIC TILE OVER CONCRETE SLAB JOINTS

8. SEE SHEET A-401 FOR TOILET ACCESSORIES SCHEDULE

ELEVATION

40" AFF

TYPICAL

PLAN

3'- 6"

3'- 6"

6'- 8"

4'- 0"

6'- 0"

4'- 0"

3" MAX

1'- 6"

4'-

2'-

1'- 6"2'-

3'- 4"

1'- 5" 3'-

0" 1'-

6"

2'-0" 1'-0" 1'-6"

8" 2'- 0"

1'-0" 4'-6"

3'- 4"

1'- 6"

3'-3"

4'- 0"

MOUNTING HEIGHT OF ITDW DETERMINED

BY MOUNTING HEIGHT OF PAPER TOWEL

DISPENSER TYPE PROVIDED

TOILET TISSUE DISPENSER

GRAB BAR: 42"

GRAB BAR: 36"

GRAB BAR: 18"

GRAB BAR: L-SHAPED 24" x 18"

SANITARY NAPKIN DISPOSAL

SANITARY NAPKIN VENDOR

PAPER TOWEL DISPENSER

INTEGRAL TOWEL DISPENSER & WASTE RECEPTACLE

PAPER TOWEL DISPENSER: "C" FOLD TYPE

PAPER TOWEL DISPENSER: ROLL TYPE

ELECTRIC HAND DRYER

SOAP DISPENSER - WALL MOUNTED

WALL MIRROR: 18" x 36"

RECESSED SOLID SURFACE SHOWER SHELF

SOLID SURFACE SHOWER SHELF

DIAPER CHANGING STATION

SHELF / MOP AND BROOM HOLDER

MOP HOOK

TOWEL BAR: 18"

SHOWER CURTAIN ROD

TOILET SEAT COVER DISPENSER

WALL MIRROR (CUSTOM): SEE ELEVATION

ROBE HOOK

FOLDING SHOWER SEAT SOAP DISPENSER - COUNTERTOP MOUNTED

ROBE HOOK - ACCESSIBLE MOUNTING HEIGHT

NOTES:

1. CLEARANCES AND HEIGHTS OF FIXTURES AND ACCESSORIES MUST BE IN COMPLIANCE WITH THE ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS FOR

DEPARTMENT OF DEFENSE FACILITIES AS ADOPTED BY DOD POLICY MEMORANDUM

2. ACCESSORIES SPECIFIED APPEAR ON DESIGNATED PLANS, HOWEVER NOT ALL ACCESSORIES SHOWN HERE MAY BE SPECIFIED. COORDINATE WITH PLAN DESIGNATIONS

3. REFERENCE THE SPECIFICATIONS FOR DETAILED PRODUCT INFORMATION INCLUDING ACCEPTABLE MANUFACTURERS, FINISHES, ETC.

4. MOUNT ACCESSORIES SUCH THAT DISPENSER OR OPERATING MECHANISM IS WITHIN ACCESSIBLE FORWARD REACH RANGES DEFINED BY THE ACCESSIBILITY STANDARDS

IDENTIFIED ABOVE

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

:5 6:

P

M

E N

LA

R

G E

D P

LA

N

S

A-401

1701820

FINAL SUBMITTAL

12903510

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

SCALE: 1/4" = 1'-0"

A2

MEN 138 ACCESSORY PLAN

SCALE: 1/4" = 1'-0"

A1

MEN 138 DIMENSION PLAN

SCALE: 1/4" = 1'-0"

A3

WOMEN 139 DIMENSION PLAN

SCALE: 1/4" = 1'-0"

B4

WOMEN 139 ACCESSORY PLAN

KEY PLAN

SCALE 1" = 60'

GENERAL CONSTRUCTION NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

AREA C AREA E

AREA D AREA F

C

B

145A

±4 '-1

±4

'-5

±4 '-5

±4

'-5

±4 '-5

±3

'-6

6" 4'-

0"

'-4

'-1

1"

'-1

1/

4"

13'-6 3/4" 1'-4 1/4"

15'-5"

3'-8" 8'-9" 4'-2"

16'-7"

'-0

'-1 0"

1'- 0"

±4 '-5

±4

'-5

±4 '-5

±4

'-5

±4 '-5

±4

'-1

1'-7"

4'-0" 5'-0" CLEAR 3'-0"

CL

EA

R

FE

ET

1'-

3'-

1"

CL

EA

R

5'- 0"

5'-6"

3'-0"

FD

FD

FD

FD

A3

D1

B1

B1

D1

A1A1

A1

F

A1A1

A1 A1

A1

D1

145A

MAINTAIN 2'-6" x 4'-0"

ACCESSIBLE CLEAR

FLOOR SPACE

MAINTAIN 5'-0" DIAMETER

ACCESSIBLE CLEAR

FLOOR SPACE

M

AI

NT

AI

N 2'-

6" x

4'- 0"

AC

CE

SS

IB

LE

C

LE

AR

FL

O O

R

SP

AC

E

FD

FD

FD

FD

D

5A

5'- 0"

±3'-2"

3'- 8"

5'-

1/ 4"

4'- 1"

5'- 6"

16'-1"

'-9

/4

2'- 7"

8'-6" 8'-1"

5'-0" CLEAR 6'-2"

'-9

/4

6'-

7"

FD

D1

D1

A3

D1

D1

A3

D1

A1

A1

A1

A1

B1

5A

MAINTAIN 2'-6" x 4'-0"

ACCESSIBLE CLEAR

FLOOR SPACE

MAINTAIN 5'-0" DIAMETER

ACCESSIBLE CLEAR

FLOOR SPACE

FD

1. FOR SYMBOL LEGEND, SEE SHEET A-001

2. PROVIDE COAT HOOKS ON THE BACK OF ALL TOILET PARTITION DOOR

3. SEE FINISH SCHEDULE ON SHEETS I-601 AND I-602

4. PROVIDE CEMENTITIOUS BOARD AT ALL SHOWER STALLS. PROVIDE GLASS MATT WATER

RESISTIVE BACKING BOARD AS SUBSTRATE TO WALL TILE. PROVIDE MOISTURE RESISTANT

GYPSUM BOARD AT THE FOLLOWING WALL AND CEILINGS THAT DO NOT RECEIVE TILE:

MEN'S TOILET, WOMEN'S TOILET UNISEX TOILET, CO TOILET.

5. PROVIDE SINGLE BASE COURSE FULLY GROUTED 6" CMU AT ALL WALLS WITHIN

DEPRESSED SLAB AREAS - SEE STRUCTURAL FOUNDATION PLAN FOR LOCATIONS AND

DEPTH OF DEPRESSED SLABS.

6. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS WALL ATTACHED

FIXTURES/ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS

7. REFER TO XX/A-XXX FOR CERAMIC TILE OVER CONCRETE SLAB JOINTS

8. SEE SHEET A-401 FOR TOILET ACCESSORIES SCHEDULE

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

:5 6:

P

M

E N

LA

R

G E

D P

LA

N

S

A-402

1701820

FINAL SUBMITTAL

12903511

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

KEY PLAN

SCALE 1" = 60'SCALE: 1/4" = 1'-0"

A2

MEN 145 DIMENSION PLAN

SCALE: 1/4" = 1'-0"

MEN 145 ACCESSORY PLAN

SCALE: 1/4" = 1'-0"

A3

WOMEN 155 DIMENSION PLAN

SCALE: 1/4" = 1'-0"

C3

WOMEN 155 ACCESSORY PLAN

GENERAL CONSTRUCTION NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

AREA C AREA E

AREA D AREA F

A

1'-4" 2'-8" 8'-0" 1'-11" 2'-4"

16'-3"

1'- 4"

'-4

/2

2'-6"

6'- 8"

1'-0"

2'- 7"

11'-9"

FD

F

B1

F

A1F

B1

A1

A

6'- 8"

2'-6"

'-4

/2

1'-0" 11'-9"

2'- 7"

1'- 4" 2'-4" 1'-11" 8'-4" 3'-0" 8"

16'-3"

FD

B1

F

B1

F

A1

A1

F

1. FOR SYMBOL LEGEND, SEE SHEET A-001

2. PROVIDE COAT HOOKS ON THE BACK OF ALL TOILET PARTITION DOOR

3. SEE FINISH SCHEDULE ON SHEETS I-601 AND I-602

4. PROVIDE CEMENTITIOUS BOARD AT ALL SHOWER STALLS. PROVIDE GLASS MATT WATER

RESISTIVE BACKING BOARD AS SUBSTRATE TO WALL TILE. PROVIDE MOISTURE RESISTANT

GYPSUM BOARD AT THE FOLLOWING WALL AND CEILINGS THAT DO NOT RECEIVE TILE:

MEN'S TOILET, WOMEN'S TOILET UNISEX TOILET, CO TOILET.

5. PROVIDE SINGLE BASE COURSE FULLY GROUTED 6" CMU AT ALL WALLS WITHIN

DEPRESSED SLAB AREAS - SEE STRUCTURAL FOUNDATION PLAN FOR LOCATIONS AND

DEPTH OF DEPRESSED SLABS.

6. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS WALL ATTACHED

FIXTURES/ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS

7. REFER TO XX/A-XXX FOR CERAMIC TILE OVER CONCRETE SLAB JOINTS

8. SEE SHEET A-401 FOR TOILET ACCESSORIES SCHEDULE

GYPSUM BOARD CEILING

2' x 2' ACOUSTICAL CEILING TILE

RECESSED 2' x 4' LIGHT FIXTURE

RECESSED 1' x 4' LIGHT FIXTURE

4' STRIP LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE

RECESSED CAN LIGHT

SURFACE MOUNTED 1' x 4' LIGHT FIXTURE

MECHANICAL SUPPLY REGISTER

MECHANICAL RETURN REGISTER

MECHANICAL EXHAUST REGISTER

2' x 2' CEILING ACCESS PANEL

ILLUMINATED EXIT SIGN

CEILING MOUNTED COMBINATION SPEAKER/CABLE STROBE

AREA SMOKE DETECTOR

CARBON MONOXIDE DETECTOR

CEILING MOUNTED OCCUPANCY SENSOR

CEILING MOUNTED EMERGENCY LIGHT FIXTURE

ACOUSTIC CEILING TILE GRID AT 9'-0" A.F.F.

OPEN TO STRUCTURE

MAINTAIN 8'-0" MINIMUM CLEAR TO UNDERSIDE OF ALL

SUSPENDED FIXTURES AND EQUIPMENT

LAUNDRY SINK

65 LB COMMERCIAL DRYER

65 LB COMMERCIAL WASHER

COMMERCIAL GRADE DRYER

COMMERCIAL GRADE WASHER

HANGING ROD AND SHELF

3'-0" x 7'-0" CASED OPENING

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

:5 6:

P

M

E N

LA

R

G E

D P

LA

N

S

A-404

1701820

FINAL SUBMITTAL

12903513

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

KEY PLAN

SCALE 1" = 60'SCALE: 1/4" = 1'-0"

A1

LAUNDRY 137 ENLARGED PLAN

SCALE: 1/4" = 1'-0"

A2

LAUNDRY 146 ENLARGED PLAN

SCALE: 1/4" = 1'-0"

C1

LAUNDRY 137 REFLECTED CEILING PLAN

SCALE: 1/4" = 1'-0"

C2

LAUNDRY 146 REFLECTED CEILING PLAN

GENERAL CONSTRUCTION NOTES

REFLECTED CEILING PLAN LEGENDREFLECTED CEILING PLAN KEYNOTES

ENLARGED PLAN KEY NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

1 1

AREA C AREA E

AREA D AREA F

C.8

D

8 9

4A 18

2A

3A

3A

0A

16'-8 5/8" 3'-6" 6'-6" 10'-0" 5'-6" 1'-0"

18'-8"

5'-0" 6'-0" 5'-8" 3'-6" 6'-6" 2'-4 1/2" 7'-7 1/2" 2'-7 3/8" 2'-10 5/8"

1'-0"

8'-2" 5'-6" 5'-0"

4" 4"

61'-10 5/8"

1'- 8"

6'- 5"

1'- 6"

1'- 5"

7'-

A1 A1

A1 A1

A3

A1

A1 A1

A1

A1

A3

A1

A1

A1

B

3'-1 5/8" 3'-1 5/8"

7 5/8" 7 5/8"

FLOOR SINK

BELOW

3'-7" 3'-1"

9'- 8" 6'-

1/

2" 1. FOR SYMBOL LEGEND, SEE SHEET A-001

2. PROVIDE COAT HOOKS ON THE BACK OF ALL TOILET PARTITION DOOR

3. SEE FINISH SCHEDULE ON SHEETS I-601 AND I-602

4. PROVIDE CEMENTITIOUS BOARD AT ALL SHOWER STALLS. PROVIDE GLASS MATT WATER

RESISTIVE BACKING BOARD AS SUBSTRATE TO WALL TILE. PROVIDE MOISTURE RESISTANT

GYPSUM BOARD AT THE FOLLOWING WALL AND CEILINGS THAT DO NOT RECEIVE TILE:

MEN'S TOILET, WOMEN'S TOILET UNISEX TOILET, CO TOILET.

5. PROVIDE SINGLE BASE COURSE FULLY GROUTED 6" CMU AT ALL WALLS WITHIN

DEPRESSED SLAB AREAS - SEE STRUCTURAL FOUNDATION PLAN FOR LOCATIONS AND

DEPTH OF DEPRESSED SLABS.

6. PROVIDE BACKING AS REQUIRED TO SUPPORT AND MOUNT VARIOUS WALL ATTACHED

FIXTURES/ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS

7. REFER TO XX/A-XXX FOR CERAMIC TILE OVER CONCRETE SLAB JOINTS

8. SEE SHEET A-401 FOR TOILET ACCESSORIES SCHEDULE

GYPSUM BOARD CEILING

2' x 2' ACOUSTICAL CEILING TILE

RECESSED 2' x 4' LIGHT FIXTURE

RECESSED 1' x 4' LIGHT FIXTURE

4' STRIP LIGHT FIXTURE

WALL MOUNTED LIGHT FIXTURE

RECESSED CAN LIGHT

SURFACE MOUNTED 1' x 4' LIGHT FIXTURE

MECHANICAL SUPPLY REGISTER

MECHANICAL RETURN REGISTER

MECHANICAL EXHAUST REGISTER

2' x 2' CEILING ACCESS PANEL

ILLUMINATED EXIT SIGN

CEILING MOUNTED COMBINATION SPEAKER/CABLE STROBE

AREA SMOKE DETECTOR

CARBON MONOXIDE DETECTOR

CEILING MOUNTED OCCUPANCY SENSOR

CEILING MOUNTED EMERGENCY LIGHT FIXTURE

ACOUSTIC CEILING TILE GRID AT 9'-0" A.F.F.

OPEN TO STRUCTURE

MAINTAIN 8'-0" MINIMUM CLEAR TO UNDERSIDE OF ALL

SUSPENDED FIXTURES AND EQUIPMENT

FULL SIZE REFRIGERATOR WITH ICE MAKER - FF&E

WALL CABINETS - REFERENCE INTERIOR DESIGN DRAWINGS

BASE CABINETS - REFERENCE INTERIOR DESIGN DRAWINGS

GEAR WASH SINK

MAINTAIN 2'-6" x 4'-0" ACCESSIBLE CLEAR FLOOR SPACE

MAINTAIN 5'-0" DIAMETER ACCESSIBLE CLEAR FLOOR SPACE

2"-8" x 2'-8" TERRAZZO FLOOR MOUNTED MOP SINK

4'-0" x 1'-0" SHELVING UNIT WITH 5 SHELVES

FAUCET SET WITH INTEGRAL STOPS, PAIL HOOK, VACUUM

BREAKER SPOUT AND 3/4" THREADED HOSE SPOUT OUTLET

1'-4" x 1'-4" FRESH AIR INTAKE LOUVRE FOR ELECTRIC WATER

COOLER CHILLER, MOUNTED 12" ABOVE FINISHED FLOOR

FOR SYMBOL LEGEND, SEE SHEET G-003

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

:5 6:

P

M

E N

LA

R

G E

D P

LA

N

S

A-405

1701820

FINAL SUBMITTAL

12903514

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1"=60'

60' 0 120'60'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

KEY PLAN

SCALE 1" = 60'

SCALE: 1/4" = 1'-0"

B1

AREA C ENLARGED PLAN

SCALE: 1/4" = 1'-0"

A1

AREA C ENLARGED PLAN

SCALE: 1/2" = 1'-0"

C1

TYPICAL GEAR WASH PLAN

SCALE: 1/4" = 1'-0"

D1

TYPICAL KITCHENETTE PLAN

GENERAL CONSTRUCTION NOTES

REFLECTED CEILING PLAN LEGEND

REFLECTED CEILING PLAN KEYNOTES

ENLARGED PLAN KEY NOTES

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

PANEL RIB INSIDE

CLOSURE

EAVE STRUT

GUTTER STRAP

ROOF STITCH

EAVE GUTTER

PRE-ENGINEERED

RAFTER

METAL CLOSURE

DOWNSPOUT

FLUSH METAL SOFFIT

PRE-ENGINEERED

COLUMN

SLOPE CONCRETE

1/8" MINIMUM AWAY

FROM COLUMN

TOP OF BRICK

SEE ELEVATIONS

+0'-0" LEVEL 1

SUSPENDED STEEL FRAMING

SYSTEM OF HEAVY DUTY 1 1/2" MAIN

RUNNERS AT 4'-0" ON CENTER AND

7/8" HAT CHANNEL CROSS RUNNERS

AT 1'-4" ON CENTER

DOWNSPOUT SUPPORT

BRICK VENEER

1/2" CMU VENEER OFFSET TO

MATCH BUILDING ELEVATION

CMU VENEER

PVC SLEEVE

DOWNSPOUT

THROUGH

FOUNDATION

1/

2" 5"

2"

2" 7 3/4"

GRID

INTERIOR EXTERIOR

TOP OF BRICK

SEE ELEVATIONS

5/8" GYPSUM BOARD

SHEATHING

3" CONTINUOUS RIGID

INSULATION

PRE-ENGINEERED METAL PANEL

AIR AND MOISTURE BARRIER

METAL STUD

METAL PANEL

CLOSURE

METAL FLASHING

SEALANT

AIR GAP

AIR AND MOISTURE BARRIER

BRICK VENEER

GYPSUM BOARD

FURRED

COLUMN

BEYOND

8".PRE-ENGINEERED

COLUMN BEYOND

HEAD JOINT RELIEF VENTS

GRID

INTERIOR EXTERIOR

5/8" GYPSUM BOARD SHEATHING

3" CONTINUOUS RIGID INSULATION

AIR AND MOISTURE BARRIER

AIR GAP

CMU MASONRY TIES

CMU SPLIT FACE VENEER

MORTAR GUARD WITH INTEGRAL INSECT

SCREEN; WEEP MESH AT 2'-0" ON CENTER

METAL FLASHING, EXTEND 8" ABOVE

DRAINAGE MATERIAL

+0'-0" LEVEL 1

CMU PRECISION VENEER STARTER COURSE

FINISHED GRADE

RIGID INSULATION FILLED

CAVITY BENEATH FLASHING

CONCRETE FOUNDATION

GYPSUM BOARD

FURRED COLUMN

BEYOND

METAL STUD

FRAMING

SEALANT

VAPOR

BARRIER

SUB BASE

.PRE-ENGINEERED

COLUMN BEYOND

6"

8"

6 5/8" 9 1/8"

PRE-ENGINEERED

COLUMN

VEE TYPE MASONRY ANCHORS

AT 1'-4" ON CENTER VERTICALLY.

WELD BRACKET TO FACE OF

STEEL COLUMN

CMU BASE COURSING.

BRICK ABOVE NOT

SHOWN FOR CLARITY

FILL SOLID WITH CONCRETE,

SEE A1/A502 FOR CAP CONDITION

2'-0"

2'- 0"

GRID

INTERIOR EXTERIOR

GYPSUM BOARD

METAL STUD

FRAMING

5/8" GYPSUM BOARD SHEATHING

1" CONTINUOUS RIGID INSULATION

CMU MASONRY TIES, TYPICAL

AIR AND MOISTURE BARRIER

CMU SPLIT FACE VENEER

MORTAR NET IN THE BOTTOM 2'-0" OF CAVITY

WEEP WITH MESH AT 2'-0" ON CENTER

METAL FLASHING, EXTEND 8" ABOVE

DRAINAGE MATERIAL

CMU PRECISION VENEER

STARTER COURSE

DOWNSPOUT

+0'-0" LEVEL 1

VAPOR BARRIER

SUB BASE

FINISHED GRADE

WHERE DOWNSPOUT DRAINS

UNDERGROUND, SEE CIVIL DRAWINGS

RIGID INSULATION FILLED CAVITY

BENEATH FLASHING

CONCRETE FOUNDATION

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

0:

:1

A M

E X

T E

R

IO

R D

E T

A

IL

S

A-505

1701820

FINAL SUBMITTAL

12903523

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

SCALE: 1 1/2" = 1'-0"

A1

BUILDING SECTION - CANOPY

SCALE: 1 1/2" = 1'-0"

A3

BUILDING SECTION - TRANSITION

SCALE: 1 1/2" = 1'-0"

A4

BUILDING SECTION - RAKE - BASE

SCALE: 1 1/2" = 1'-0"

C4

COLUMN AT CANOPY

SCALE: 1 1/2" = 1'-0"

C3

BUILDING SECTION - BASE

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

SLOPE

CURB FLASHING

(SIDE)

CURB FLASHING

(DOWNHILL)

CURB FLASHING

(SIDE)

CURB FLASHING (UPHILL). FOR

CURBS WIDER THAN 3'-0",

A WELDED CRICKET IS REQUIRED

NOTE:

1. INSTALL PER MANUFACTURER RECOMMENDATIONS

VENT PIPE

SEAL AT BASE WITH

GUNNABLE SEALANT

ETHYLENE PROPYLENE

DIENE MONOMER PIPE

FLASHING

BASE FLASHING

STANDING SEAM METAL

ROOF PANEL

NOTE:

1. PENETRATIONS SHOULD BE CENTERED IN PANELS

2. ATTACH ROOF JACK TO STANDING SEAM ROOF PANEL ONLY

3"

MI

N

RIDGE CLOSURE

ROOF SEAM CAP

AIR AND MOISTURE

BARRIER - EXTEND 8"

BUTYL TAPE UNDER

SEAM CAP

THERMAL BREAK

TOP / BOTTOM

METAL ROOF

METAL BUILDING

SYSTEM INSULATION

AND LINER SHEET

1/4" x 2" INSULATION

STRAP

RAKE BEAM

8"8"

SL

OP

E

SLOPE

SLOPE

INSTALL SEALANT IN

ENDS OF VERTICAL

SEAMS

CENTER RIB (1" MINIMUM

HEIGHT)

METAL CLIP APPROXIMATELY

2" WIDE BEND CLIP OVER

FASTENERS

PEEL AND STICK

ROOF PANEL

4" PANEL OVERLAP ONTO

VALLEY METAL FLANGE

STRUCTURAL

FRAMING MEMBER

HEAVY-GAUGE VALLEY

LINER SUPPORT METAL

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

1:

:3

A M

R O

O F

D E

T A

IL

S

A-510

1701820

FINAL SUBMITTAL

12903528

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 3"=1'-0"

0 3" 6" 1"

SCALE: 1/2" = 1'-0"

A2

ROOF CURB DETAIL

SCALE: 3" = 1'-0"

A4

PIPE FLASHING

SCALE: 1 1/2" = 1'-0"

C2

ROOF RIDGE DETAIL

SCALE: 1 1/2" = 1'-0"

C4

ROOF VALLEY DETAIL

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

GRAPHIC SCALE: 1/2"=1'-0"

2' 0 1' 2' 4'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

T T T

T

T

T

T

T TTT

T T

ADHESIVE LOGO

PER INTERIORS

SIGNAGE

LOCATIONS: SEE

B3/A-631

7'- 0"

'-0

2" 2'-

8" 2"

3'- 8"

2" 3'-

0" 2"

18'-8"

2" 2'-11"

2" 2'-11"

2" 6'-0"

2" 2'-11"

2" 2'-11"

2"

'-0

2" 2'-6"

2" 5'-8"

2"

8'-8"

T

T T

T

T T T

T

T T

T

'-0

7'- 0"

2" 2'-

8" 2"

3'- 8"

2" 3'-

0" 2"

2" 2'-11"

2" 2'-11"

2" 6'-0"

2" 2'-11"

2" 2'-11"

2"

18'-8"

3'- 4"

5'- 4"

20'-0"

2"

EQ

2"

EQ

2"

EQ

2"

EQ

2"

EQ

2"

EQ

2"

EQ

2"

T

T

T

T

TT

T T

9'- 8"

2" 2'-

4" 2"

3'- 8"

2" 3'-

0" 2"

8'-4"

2" 10"

2" 2'-11"

2" 2'-11"

2" 10"

2"

120 SF

A B F

TP3

4'-8"

5'- 4"

5'- 4"

2'- 4"

6'-6"

8'-0"

2" 2'-

0" 2"

2" 3'-0"

2" 3'-0"

2"

3/

4" 3'-

1/ 2"2"

1'-

1/ 2"

3/

4"

1 3/4" 1'-9 1/4"

2" 1'-9 1/4"

2" 1'-9 1/4" 2"

1'-9 1/4" 1 3/4"

3/

4"

3'-

1/ 2"

2"

1'-

1/ 2"

3/

4"

1 3/4" 2'-0 1/2"

2" 2'-0 1/2" 1 3/4"

24'-0"

5'- 0"

STEEL FRAMEALUMINUM FRAMEALUMINUM FRAME

ALUMINUM FRAME

1. SEE SPECIFICATIONS FOR HARDWARE GROUPS

2. REFER TO DOOR SCHEDULE FOR STOREFRONT DOOR DETAILS

3. FOR SYMBOL LEGEND, SEE SHEET G-003

AL ALUMINUM

FF FACTORY FINISH

HM HOLLOW METAL

PT FIELD PAINTED

SCWD SOLID CORE WOOD DOOR

ST STAINED

T TEMPERED GLAZING

F F

TTTTTT

2" 2'-

0" 2"

7'- 0"

9'- 4"

2'-6 3/8"

2"

3'-0"

2"

3'-0"

2"

EQ EQ

2"

3'-0"

2"

3'-0"

2"

6'-6"6'-6" 6'-6"

2"

3'-0"

2"

3'-0"

2"

2'-6 3/8"

7'-

0"STEEL FRAMES, TYPICAL

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO BLDG

A2

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

2.

rv t 6/

9/

0:

:1

A M

W

IN

D O

W S

C H

E D

U

LE

S A

N D

D E

T A

IL

S

A-605

1701820

FINAL SUBMITTAL

12903537

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

GRAPHIC SCALE: 1/4"=1'-0"

4' 0 2' 4' 8'

SCALE: 1/4" = 1'-0"

C1

VESTIBULE A-1

SCALE: 1/4" = 1'-0"

C2

VESTIBULE A-2

SCALE: 1/4" = 1'-0"

C3

LOBBY A-3

SCALE: 1/4" = 1'-0"

C4 A-5

SCALE: 1/4" = 1'-0"

B5

LOBBY A-4WINDOW LEGEND

GENERAL CONSTRUCTION NOTES

MATERIAL & FINISHES

SCALE: 1/4" = 1'-0"

B3

TEAM OPS TRANSOM ELEVATION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

1 11

25'-4" 62'-6" 12'-0" 12'-8" 5'-8" 8'-1" 10'-4" 5'-5"

2 3 4 5 6

A

B

E

C

D

1'- 4"

'-0

'-8

'-8

'-0

1'-

5/

27'-4" 26'-0" 28'-0" 28'-0" 28'-0"

29'-8" 3'-4" 3'-4" 12'-0" 54'-8" 3'-4"

33'-4" 3'-4" 39'-4" 3'-4" 5'-8" 3'-4"

B4

A-301

B4

A-301

'-0

/1

6"

D3

A-301

D3

A-301

4'-

5/

6'-

4" 8'-

0" 6'-

4"

'-4

1'-8"1'-4" 1'-8" 1'-8" 1'-8"

1'-8" 1'-8"1'-4"

'-2

'-7

'-2

'-5

/1 6"1'-

8" 1'-

8"

COORDINATE EXACT

CHASE DIMENSIONS WITH

APPROVED DRINKING

FOUNTAIN

1'-8"

9'-

A-401 A4

109A

0A

109B 108C

8D

113A

1G

4A

6A

9A

7A

5A

1A

8B

8A

112A

111A

B

A

-1

FD

FD

FD

FD

FD FD

FDA

C

A

C

C

C

A A

A

A

B B B B

B B

B B

B A1

D

D

D

D

AREA A AREA B

WIRE MESH PARTITION. EXTEND TO THE UNDERSIDE OF

THE STRUCTURE ABOVE

ACCESSIBLE ELECTRIC WATER COOLER

COLUMN ENCLOSURE. SEE DETAIL

BOLLARD

METAL BUILDING CANOPY ABOVE

1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND

2. REFERENCE SHEET A-501 FOR WALL TYPES

3. REFERENCE SHEET A-601 FOR DOOR AND FRAME SCHEDULE

4. REFERENCE SHEET A-60X FOR WINDOW SCHEDULE

5. REFERENCE INTERIOR DESIGN DRAWINGS FOR FINISH SCHEDULE

6. REFERENCE INTERIORS DRAWINGS FOR CASEWORK DIMENSIONS AND DETAILS

7. REFERENCE THE LIFE SAFETY DRAWINGS FOR LOCATIONS OF RATED WALLS

AND SMOKE PARTITIONS

8. REFERENCE SHEET A-104 FOR AIR AND MOISTURE BARRIER PLAN AND DETAILS

9. DIMENSIONS ARE TAKEN FROM FACE OF METAL STUD AND FACE OF CMU

10. PROVIDE TREATED WOOD BLOCKING TO SUPPORT WALL MOUNTED AND

RECESSED FIXTURES, ACCESSORIES, FLAT PANEL DISPLAY MOUNTS, ETC.

FOLLOW MANUFACTURERS RECOMMENDATIONS

11. SLOPE SETTING BED FLOORS 1/8" MINIMUM TO ALL FLOOR DRAINS

12. PROVIDE FULL HEIGHT STAINLESS STEEL CORNER GUARDS AT EXPOSED

CORNERS OF GYPSUM PARTITIONS

13. PROVIDE FIRE RATED PLYWOOD BACKBOARD AT COMM ROOMS

14. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS WHERE

NOT CONNECTED TO STORM DRAIN PIPING

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO STG

A3

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

3.

rv t 6/

9/

1:

:4

A M

F

LO

O R

P

LA

N

A R

E A

A

A-102

1701820

FINAL SUBMITTAL

12903762

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

SCALE: 1/8" = 1'-0"

B1

FLOOR PLAN - AREA A

GRAPHIC SCALE: 1"=40'

40' 0 80'40'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

CONSTRUCTION KEYNOTES

GENERAL CONSTRUCTION NOTES

KEY PLAN 1" = 40'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

AREA A AREA B

7 8 9 10

A

B

E

C

D

28'-0" 28'-0" 26'-0" 2'-0"

3'-4" 55'-4" 12'-0" 2'-8" 3'-4" 4'-4"

3'-4" 74'-8" 3'-4" 8'-0"

B1

A-301

B1

A-301

D3

A-301

D3

A-301

1'-8" 1'-8"1'-8"

1'- 8"

1'- 8"

1'-8" 1'-8" 1'-8"

COORDINATE EXACT

CHASE DIMENSIONS WITH

APPROVED DRINKING

FOUNTAIN

A-401 A3

1F

101E 10 1D

1C

1B

7A

8A

B

A

-1

B B

B

A

A

A

D

D

D

D

ACCESSIBLE ELECTRIC WATER COOLER

COLUMN ENCLOSURE. SEE DETAIL

BOLLARD

1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND

2. REFERENCE SHEET A-501 FOR WALL TYPES

3. REFERENCE SHEET A-601 FOR DOOR AND FRAME SCHEDULE

4. REFERENCE SHEET A-60X FOR WINDOW SCHEDULE

5. REFERENCE INTERIOR DESIGN DRAWINGS FOR FINISH SCHEDULE

6. REFERENCE INTERIORS DRAWINGS FOR CASEWORK DIMENSIONS AND DETAILS

7. REFERENCE THE LIFE SAFETY DRAWINGS FOR LOCATIONS OF RATED WALLS

AND SMOKE PARTITIONS

8. REFERENCE SHEET A-104 FOR AIR AND MOISTURE BARRIER PLAN AND DETAILS

9. DIMENSIONS ARE TAKEN FROM FACE OF METAL STUD AND FACE OF CMU

10. PROVIDE TREATED WOOD BLOCKING TO SUPPORT WALL MOUNTED AND

RECESSED FIXTURES, ACCESSORIES, FLAT PANEL DISPLAY MOUNTS, ETC.

FOLLOW MANUFACTURERS RECOMMENDATIONS

11. SLOPE SETTING BED FLOORS 1/8" MINIMUM TO ALL FLOOR DRAINS

12. PROVIDE FULL HEIGHT STAINLESS STEEL CORNER GUARDS AT EXPOSED

CORNERS OF GYPSUM PARTITIONS

13. PROVIDE FIRE RATED PLYWOOD BACKBOARD AT COMM ROOMS

14. PROVIDE CONCRETE SPLASH BLOCKS AT ALL DOWNSPOUT LOCATIONS WHERE

NOT CONNECTED TO STORM DRAIN PIPING

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO STG

A3

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

3.

rv t 6/

9/

1:

:5

A M

F

LO

O R

P

LA

N

A R

E A

B

A-103

1701820

FINAL SUBMITTAL

12903763

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

GRAPHIC SCALE: 1"=40'

40' 0 80'40'

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

SCALE: 1/8" = 1'-0"

B2

FLOOR PLAN - AREA B

CONSTRUCTION KEYNOTES

GENERAL CONSTRUCTION NOTES

KEY PLAN 1" = 40'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

3 ROWS OF CHANNEL

STIFFENERS, MIN

ACOUSTICAL INSULATION

METAL STUDS AT

1'-4" ON CENTER

3 5/8"

GYPSUM BOARD

NOTES:

1. UTILIZE UL ASSEMBLY U 419 1/2 HOUR AND 1 HOUR

RATED WALL LOCATIONS

WALL TYPE NOTES:

1. WALL TYPES AS INDICATED ON FLOOR PLANS

2. GYPSUM BOARD IS TO BE 5/8",TYPE X, MOISTURE RESISTANT, HIGH IMPACT UNLESS SPECIFICALLY NOTED OTHERWISE

3. PROVIDE 5/8" CEMENTITIOUS BACKER BOARD WHERE CERAMIC TILE IS SCHEDULED ON WALLS

4. SMOKE PARTITIONS AND RATED WALLS MUST BE PROPERLY SEALED TO THE UNDERSIDE OF THE DECK ABOVE. PROVIDE SCHEDULE 40 SLEEVES AT PIPE PENETRATIONS IN RATED PARTITIONS AND SEAL ANNULAR SPACE WITH RATED SEALANT. REFERENCE MECHANICAL DRAWINGS FOR MECHANICAL DUCT DAMPER LOCATIONS. REFERENCE THE LIFE SAFETY DRAWINGS FOR RATED WALL AND SMOKE

PARTITION LOCATIONS

5. WALL FRAMING MUST BE EXTENDED TO THE UNDERSIDE OF THE DECK ABOVE AT ALL LOCATIONS FOR BRACING. EXTEND GYPSUM BOARD

TO FULL HEIGHT OF WALLS

6. WALLS, INCLUDING GYPSUM BOARD WHERE SCHEDULED, AT MECHANICAL ROOMS, ELECTRICAL ROOMS, EQUIPMENT ROOMS, JANITOR CLOSETS, TOILETS AND CORRIDORS MUST BE EXTENDED TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. INSTALL

AIR BARRIER SEALANT PERIMETER OF WALL

BRICK VENEER

MASONRY TIE, 1'-4" ON CENTER

VERTICALLY AND HORIZONTALLY

CAVITY AND AIR SPACE

R-15 RIGID INSULATION TAPE ALL JOINTS

GYPSUM BOARD SHEATHING

STRUCTURAL STEEL STUDS

PER DELEGATED DESIGN

CHANNEL STIFFENERS PER

DELEGATED DESIGN

GYPSUM BOARD

WALL - MID

AIR AND MOISTURE BARRIER

3" 5/8" 6" 5/8"

FLUSH METAL WALL PANELS

GALVANIZED SLOTTED HAT CHANNELS

AT 2'-0" ON CENTER MAX. ATTACH TO

EACH STUD

R-15 RIGID INSULATION TAPE ALL JOINTS

GYPSUM BOARD SHEATHING

STRUCTURAL STEEL STUDS

PER DELEGATED DESIGN

CHANNEL STIFFENERS PER

DELEGATED DESIGN

GYPSUM BOARD

AIR AND MOISTURE BARRIER

3" 5/8" 6" 5/8"

WALL - UPPER

4" ROCKFACE CMU

MASONRY TIE, 1'-4" ON CENTER

VERTICALLY AND HORIZONTALLY

CAVITY AND AIR SPACE

R-15 RIGID INSULATION TAPE ALL JOINTS

GYPSUM BOARD SHEATHING

STRUCTURAL STEEL STUDS

PER DELEGATED DESIGN

CHANNEL STIFFENERS PER

DELEGATED DESIGN

GYPSUM BOARD

WALL - BASE

AIR AND MOISTURE BARRIER

3" 5/8" 6" 5/8"

NOTES:

1. REFERENCE THE BUILDING SECTIONS FOR HEIGHT OF TRANSITION BETWEEN

LOWER AND UPPER WALL CONSTRUCTION

1'-4 5/8"

1'-4 5/8"

3 ROWS OF CHANNEL

STIFFENERS, MIN

ACOUSTICAL INSULATION

METAL STUDS AT

1'-4" ON CENTER

6"

GYPSUM BOARD

NOTES:

1. UTILIZE UL ASSEMBLY U 419 1/2 HOUR AND 1 HOUR

RATED WALL LOCATIONS

3 ROWS OF CHANNEL

STIFFENERS, MIN

3-5/8" METAL STUDS

AT 1'- 4" ON CENTER

GYPSUM BOARD

3 5/8"

CHASE

2'-6"

WALL TYPE A

NOTES:

1. PROVIDE 5/8" CEMENTITIOUS BACKER BOARD IN LIEU OF 5/8"

GYPSUM BOARD AT WALLS TO RECEIVE PORCELAIN WALL TILE.

3 ROWS OF CHANNEL

STIFFENERS, MIN

METAL STUDS AT

1'-4" ON CENTER

GYPSUM BOARD

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO STG

A3

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

3.

rv t 6/

9/

1:

:5

A M

W A

LL

T

Y P

E D

E T

A

IL

S

A-501

1701820

FINAL SUBMITTAL

12903775

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

SCALE: 1 1/2" = 1'-0"

B

3 5/8" INTERIOR PARTITION

SCALE: 1 1/2" = 1'-0"

A

6" METAL STUD EXTERIOR WALL

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

SCALE: 1 1/2" = 1'-0"

C

6" INTERIOR PARTITION

SCALE: 1 1/2" = 1'-0"

A1

EXTERIOR WALL WITH CHASE

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

SCALE: 1 1/2" = 1'-0"

D

3 5/8" CHASE WALL

ROOF SEAM CAP

PEEL AND STICK (AIR BARRIER) -

EXTEND 8"

BUTYL TAPE UNDER

SEAM CAP

RIDGE CLOSURE

THERMAL BLOCK

METAL ROOF

METAL BUILDING

SYSTEM INSULATION

AND LINER SHEET

INSULATION

SYSTEM STRAP

8"8"

VENT PIPE

SEAL AT BASE SEALANT

METAL BUILDING SYSTEM

PANEL FLASHING

BASE FLASHING

METAL BUILDING

SYSTEM ROOF PANEL

NOTE:

1. PENETRATIONS SHOULD BE CENTERED IN PANELS

2. ATTACH ROOF JACK TO STANDING SEAM ROOF PANEL ONLY

3"

MI

N

RAKE TRIM

BOTTOM OF

ROOF PAN

METAL BUILDING

SYSTEM FASTENERS

CONT. RAKE CLIP

ADAPTOR TRIM

METAL BUILDING

SYSTEM WALL

PANEL

METAL BUILDING

SYSTEM FASTENERS

METAL BUILDING

SYSTEM FASTENERS

TAPE MASTIC

2"

1/ 4"

3/

4"

9"

2 3/4" 2 3/4" 1 3/4"

METAL BUILDING SYSTEM

ROOF PURLIN

METAL BUILDING SYSTEM

ROOF PANEL

METAL BUILDING SYSTEM

GUTTER (6" x 6")

METAL BUILDING SYSTEM

DOWNSPOUT

(3 3/4" x 4 3/4")

METAL BUILDING FASCIA

RIGID INSULATION

5/8" GYPSUM BOARD

SHEATHING

AIR AND MOISTURE

BARRIER

METAL BUILDING SYSTEM

WALL PANEL

METAL BUILDING INSULATION

SYSTEM AND LINER SHEET.

EXTEND TO EAVE

INSULATION SYSTEM STRAP

METAL BUILDING FRAME

BEYOND

5/8" GYPSUM BOARD

6" STEEL STUDS

THERMAL ISOLATION BLOCK

METAL WALL PANEL

HAT CHANNEL

METAL WALL PANEL

CLOSURE

METAL COUNTERFLASHING

AND CONTINUOUS CLEAT

NOTES:

1. PREDRILL FASTENERS IN BRICK MASONRY

2. FASTEN CLEAT AT 2'-0" ON CENTER

3. COUNTERFLASHING LAP JOINTS MUST PROVIDE 4"

MINIMUM OVERLAP. PROVIDE CONCEALED SEALANT AT

LAPS

SEE WALL TYPE A

DETAIL

A1/A-501 FOR

COMPLETE

MATERIAL

INFORMATION

9'-4"

AFF

TOB

2"

HEAD JOINT RELIEF VENTS

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

CO STG

A3

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ A

3.

rv t 6/

9/

1:

:5

A M

R O

O F

D E

T A

IL

S

A-506

1701820

FINAL SUBMITTAL

12903780

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

SCALE: 1 1/2" = 1'-0"

C1

ROOF RIDGE DETAIL

SCALE: 3" = 1'-0"

A4

PIPE FLASHING

SCALE: 3" = 1'-0"

C3

RAKE DETAIL

SCALE: 1 1/2" = 1'-0"

A2

TYPICAL EAVE DETAIL

SCALE: 1 1/2" = 1'-0"

C4

COUNTERFLASHING DETAIL

GRAPHIC SCALE: 3"=1'-0"

0 3" 6" 1"

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

BUILDING A66

2D BN MONUMENT

EXISTING MONUMENT

LOCATION AT BUILDING A66

NEW MONUMENT LOCATION AT

P-1550 A1 BUILDING

STONE BAY GATE

MARSOC GATE

SUGGESTED

ROUTE

6"

4'

- 6

/8

± 6" 5' - 0 1/2" ± 6"

±6'-0 1/2"

1'

- 6

/8

3'

- 0

±6" 2' - 0 3/8" ±6"

3' - 0 1/2"

GRANITE

MONUMENT

GRANITE BASE

GRANITE

MONUMENT

GRANITE BASE

GRANITE

MONUMENT

GRANITE BASE

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A.

P.

STCETIHCRA

FB

BERN N.C.NEW

UTCETIHCRA

DERETSI

G E R

NO

IT

AR

OP

RO

C

LAR

CAROLINANORTH

T

T C

E

TI

HCRAD

R E

G I S

ERE

A

NI

LORA

N O

R

T H C

N

DA

R

N

DE

.J UE

ER

III

CNNRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

LA

N

T

IC

AS INDICATED

SITE

S

S :\p ro je ct s\

\2

M

ID

LA

N T

C L

P -1

S O

F M ar in e B at ta lio n

C om pa ny

T ea m F ac ili tie s\

D es ig n\

D w gs \2

A R

C H

3_ P

-1

S ite .r vt 6/

9/

:5 7:

A

M

2D B

N M

O N

U M

E N

T R

E

LO

C A

T

IO

N

A-102

OF

1701820

FINAL SUBMITTAL

12903080

REL ESS DJE,III

SGL/MDM

DJD

JWJ

HPN

08 MAY 2026

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A T

T A

LI

O

N

C O

M P

A N

Y

T E

A M

F A

C

IL

IT

IE

S

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

GRAPHIC SCALE: 3/4"=1'-0"

1' 0 1' 2' 3'

GRAPHIC SCALE: 1/4"=1'-0"

4' 0 2' 4' 8'

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R

E V

IS

IO

N S

.0 6.

SCALE: 1" = 60'-0"

A2

MONUMENT LOCATION

SCALE: 1" = ONE STATUTE MILE

D2

RELOCATION MAP

SCALE: 12" = 1'-0"

D5

PHOTOGRAPHIC DOCUMENTATION

SCALE: 12" = 1'-0"

D3

PHOTOGRAPHIC DOCUMENTATION

SCALE: 12" = 1'-0"

C3

PHOTOGRAPHIC DOCUMENTATION

SCALE: 12" = 1'-0"

C5

PHOTOGRAPHIC DOCUMENTATION

SCALE: 3/4" = 1'-0"

A4

MONUMENT DIMENSIONS

2D MARINE RAIDER BATTALION MONUMENT RELOCATION

1. THE EXISTING MONUMENT IS LOCATED ADJACENT TO

BUILDING A66 AT THE AMPHIBIOUS BASE ARE OF MCB

CAMP LEJEUNE NEAR COURTHOUSE BAY

2. RELOCATE MONUMENT AND BASE TO THE P-1550

PROJECT SITE AT MARSOC

3. LOCATE MONUMENT ADJACENT TO THE ENTRANCE OF

THE A1 BUILDING. EXACT LOCATION MUST BE

COORDINATED WITH MARSOC G-4 CAPITAL

CONSTRUCTION BRANCH

4. PROVIDE 1' DEEP COMPACTED STONE BASE

EVERETT CREEK RD

J

ES104

ES102 ES103

SL1

SL3

ES103

ES104

ES103

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

PLAN NOTES:

PROVIDE UNDERGROUND, MEDIUM VOLTAGE PRIMARY

FEEDER. SEE DUCT BANK DETAILS AND ELECTRICAL

RISER DIAGRAM FOR MORE INFORMATION.

PROVIDE ABOVE-GROUND, MEDIUM VOLTAGE

JUNCTION BOX ON CONCRETE BOXPAD.

3 PROVIDE SITE LIGHTING FIXTURE AT 30 FEET ABOVE

FINISHED GRADE ON ALUMINUM POLE. TYPICAL.

S

IT

E P

LA

N

E

LE

C

TR

IC

A L

ES103

A2 SITE PLAN - ELECTRICAL

SCALE: 1/40" = 1'-0"

0 20' 40' 80'40'

GRAPHIC SCALE: 1/40"=1'-0"

N

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS INDICATED

OF 262

1701820

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

SITE

S

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A

TT

A

LI

O N

C

O M

P A

N Y

TE

A M

F A

C

IL

IT

IE

S

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y N

A V

A L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

M

ID

LA

NT

D C

CO

RE

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V

A

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

A

TL

A N

TI

C

SGL/MDM

FINAL SUBMITTAL

JWJ

WRB

HPN

MKW JTRJTR

12903053

S

IT

E

E

LE

C

TR

IC

A

L R

E V

IS

IO

N

J U

N

BLDG

A1

T CREEK RD

EVERETT CREEK RD

BLDG

A2-1

H

Y D

HY

D

HY

D

H Y D

H Y

D

H Y

D

H Y

D

H Y

D

S

H Y

D

CO

CO

S

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

ES104

SL1

SL1

SL1

SL1

SL1

SL3

SL3

F

F F

SL1

SL1

SL1

SL2

SL2

SL2

SL2

J

T

UGE

UGE

UGE

UGE

UGE

T

J

SL3

ES103

ES104

ES103

SW2

PB4-38,40,42

PC4-38,40,42

L1-38

THRU CONTACTOR

L1-40

THRU CONTACTOR

L1-42

THRU CONTACTOR

LS-2

THRU CONTACTOR

J

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E 1

UG

E

UGE

UGE

UGESL3

SL1

SL2

SL3

SL2

SL2

SL2

SL1

SL1

SL1

ES104

ES105

J

UG

E

UG

E

UG

E

UG

E

UGE

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E1

A1

A1

A1

A1

A1

UGE

UGE

UGE

UGE

UGE

GE

PLAN NOTES:

PROVIDE UNDERGROUND, MEDIUM VOLTAGE PRIMARY

FEEDER. SEE DUCT BANK DETAILS AND ELECTRICAL

RISER DIAGRAM FOR MORE INFORMATION.

PROVIDE SECONDARY ELECTRICAL SERVICE

CONDUCTORS FOR NEW BUILDING. RUN ONE ADDITIONAL

1" CONDUIT WITH PULL WIRE TO PAD-MOUNT

TRANSFORMER FOR CONNECTION TO METER. SEE DUCT

BANK DETAILS AND ELECTRICAL RISER DIAGRAM.

PROVIDE SITE LIGHTING FIXTURE AT 30 FEET ABOVE

FINISHED GRADE ON ALUMINUM POLE. TYPICAL.

PROVIDE ABOVE-GROUND, MEDIUM VOLTAGE

JUNCTION BOX ON CONCRETE BOXPAD.

NEW PAD-MOUNT TRANSFORMER FOR NEW BUILDING

ON CONCRETE BOXPAD. SEE ELECTRICAL RISER

DIAGRAM FOR MORE INFORMATION.

6 PROVIDE 431 DEAD-FRONT, PAD-MOUNTED, MEDIUM

VOLTAGE SWITCH. SWITCH MUST HAVE OVERCURRENT

PROTECTION ON PROTECTED WAY. PROVIDE CONTROLS

FOR PROTECTED WAY THAT ARE COMPATIBLE WITH

CAMP LEJEUNE ELECTRICAL SCADA AND ATO. SEE

ELECTRICAL RISER DIAGRAM FOR MORE INFORMATION.

7 LIFT STATION. SEE SHEET 'ES105' FOR MORE

INFORMATION.

POLE MUST HAVE A PENETRATION AT 12 FEET A.F.G.

FOR FUTURE CCTV CAMERA. PROVIDE (1) 1-1/4"

CONDUIT FROM POLE WITH PULL WIRE TO MAIN

TELECOMM ROOM IN THE NEAREST BUILDING.

COORDINATE LOCATIONS WITH CONTRACTING

OFFICER PRIOR TO BEGINNING WORK.

8 CONNECT VEHICLE ACCESS GATE AND PEDESTRIAN

GATE. PROVIDE 2-2" CONDUITS FOR COMM AND

SECURITY TO EACH GATE. ROUTE BACK TO NEAREST

COMM ROOM IN ADJACENT BUILDING 'A1'. COORDINATE

EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER.

PROVIDE 2-#6, 1-#8 GROUND, 1" CONDUIT FOR ENTIRE

LENGTH OF CIRCUIT.

S

IT

E P

LA

N

E

LE

C

TR

IC

A L

ES104

A2 SITE PLAN - ELECTRICAL

SCALE: 1/40" = 1'-0"

0 20' 40' 80'40'

GRAPHIC SCALE: 1/40"=1'-0"

N

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS INDICATED

OF 262

1701820

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

SITE

S

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A

TT

A

LI

O N

C

O M

P A

N Y

TE

A M

F A

C

IL

IT

IE

S

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y N

A V

A L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

M

ID

LA

NT

D C

CO

RE

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V

A

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

A

TL

A N

TI

C

SGL/MDM

FINAL SUBMITTAL

JWJ

WRB

HPN

MKW JTRJTR

12903054

S

IT

E

E

LE

C

TR

IC

A

L R

E V

IS

IO

N

J U

N

BLDG

A3

BLDG

A2-2

BLDG

A2-1

S

S

H Y

D

CO

S

26.5

CO

CO

CO

T

UG

E

UGE

UGE

UGESL3

SL3

SL2

SL1

T

J 4

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

UGE

UGE J

SL3

ES104

ES105

L1-42

THRU CONTACTOR

L1-40

THRU CONTACTOR

PA4-32,34,36

UG

E

UG

E

UG

E

U G

E

UGE

UGE

UGE

UGE

UGE

UGE

SL3

SL3

SL3

SL3

SL3

SL3

SL1

SL1

SL2

SL2

SL2

SL1

T

J

SL1

SL3

PA4-32,34,36

SL2

L1-40

THRU CONTACTOR

7 L1-42

THRU CONTACTOR

CCTV

ES

ES

A2

A2

A2

A2

A2

A2

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

PLAN NOTES:

PROVIDE UNDERGROUND, MEDIUM VOLTAGE PRIMARY

FEEDER. SEE DUCT BANK DETAILS AND ELECTRICAL

RISER DIAGRAM FOR MORE INFORMATION.

PROVIDE ABOVE-GROUND, MEDIUM VOLTAGE

JUNCTION BOX ON CONCRETE BOXPAD.

PLAN NOTES:

NEW SECONDARY ELECTRICAL SERVICE CONDUCTORS

FOR NEW BUILDING. RUN ONE ADDITIONAL 1" CONDUIT

WITH PULL WIRE TO PAD-MOUNT TRANSFORMER FOR

CONNECTION TO METER. SEE DUCT BANK DETAILS

AND ELECTRICAL RISER DIAGRAM.

PROVIDE SITE LIGHTING FIXTURE AT 30 FEET ABOVE

FINISHED GRADE ON ALUMINUM POLE. TYPICAL.

NEW PAD-MOUNT TRANSFORMER FOR NEW BUILDING

ON CONCRETE BOXPAD. SEE ELECTRICAL RISER

DIAGRAM FOR MORE INFORMATION.

PROVIDE 2-#6, 1-#8 GROUND, 1" CONDUIT FOR ENTIRE

LENGTH OF CIRCUIT.

CONNECT VEHICLE ACCESS GATE AND PEDESTRIAN

GATE. PROVIDE 2-2" CONDUITS FOR COMM AND

SECURITY TO EACH GATE. ROUTE BACK TO NEAREST

COMM ROOM IN ADJACENT BUILDING 'A2'. COORDINATE

EXACT REQUIREMENTS WITH EQUIPMENT SUPPLIER.

PROVIDE CCTV CAMERA POLE WITH PENETRATION AT

12 FEET A.F.F. FOR CCTV CAMERA. PROVIDE (1) 1-1/4"

CONDUIT FROM POLE WITH PULL WIRE TO MAIN

TELECOMM ROOM IN THE NEAREST BUILDING.

COORDINATE LOCATIONS WITH CONTRACTING

OFFICER PRIOR TO BEGINNING WORK.

POLE MUST HAVE A PENETRATION AT 12 FEET A.F.G.

FOR FUTURE CCTV CAMERA. PROVIDE (1) 1-1/4"

CONDUIT FROM POLE WITH PULL WIRE TO MAIN

TELECOMM ROOM IN THE NEAREST BUILDING.

COORDINATE LOCATIONS WITH CONTRACTING

OFFICER PRIOR TO BEGINNING WORK.

NEW SECONDARY ELECTRICAL SERVICE CONDUCTORS

FOR FIRE PUMP. SEE DUCT BANK DETAILS AND

ELECTRICAL RISER DIAGRAM.

S

IT

E P

LA

N

E

LE

C

TR

IC

A L

ES105

A2 SITE PLAN - ELECTRICAL

SCALE: 1/40" = 1'-0"

0 20' 40' 80'40'

GRAPHIC SCALE: 1/40"=1'-0"

N

MKW JTRJTR

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

DRAWFORM REVISION: 25 AUGUST 2020

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

JE

U

N E

, N C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS INDICATED

OF 262

1701820

S Y

M D

E S

C R

IP

TI

O N

D A

TE

A

P P

R

SITE

S

P -1

S O

F M

A R

IN

E

R A

ID

E

R B

A

TT

A

LI

O N

C

O M

P A

N Y

TE

A M

F A

C

IL

IT

IE

S

D E

P A

R

TM

E N

T O

F

TH

E N

A V

Y N

A V

A L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

TE

M

S C

O M

M A

N D

M

ID

LA

NT

D C

CO

RE

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V

A

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D

M

ID

A

TL

A N

TI

C

SGL/MDM

FINAL SUBMITTAL

JWJ

WRB

HPN

12903055

S

IT

E

E

LE

C

TR

IC

A

L R

E V

IS

IO

N

J U

N

R

IFLE

R A

N G

E R

D

COCO

T AC

BUILDING

ACEE

E

EE

GROUND ROD

GROUND ROD

BUILDING

BUILDING

T

T

T T

T

T T

T T

T

T T

T

T T

T T

T

T

T

T T T T T T

T

T

T T

T T

T T

T T

T T

T

T

T

T

T

T

T

T

T

T

EE

E

E E

E E

E E E

E E

E E

EE

W

W

W

W

E E

T G

C C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M C

O M

M

COMM

COMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMC…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .