P702 Structural Drawings.pdf
PDF 369 KB Posted
- Solicitation number
- N4008523R2562
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W12X26
TOF X' - X"
FRAMING SIZE
X
TOP OF FOUNDATION
COLUMN GRID MARK
WORK KEY NOTE
TOC X' - X" TOP OF CONCRETE
TOS X' - X" TOP OF STEEL
TOM X' - X" TOP OF MASONRY
X" TOP OF SLAB
SPOT ELEVATION
BOS X' - X" BOTTOM OF STEEL
P-X PEDESTAL
MCJ MASONRY CONSTRUCTION JOINT
WFX.X WALL FOOTING
CFX.X COLUMN FOOTING
CMU
CONCRETE
EARTH
STEEL
DESIGN WIND PRESSURES FOR ROOF COMPONENTS (PSF)
COMPONENT TRIBUTARY AREA (SQFT)
1 - 100 101+
ROOF ZONE
(STORAGE)
1,2e
2n,2r,3e
DESIGN WIND PRESSURES FOR WALL COMPONENTS (PSF)
COMPONENT TRIBUTARY AREA (SQFT)
1 - 100 101+WALL ZONE
TABLE NOTES:
1. POSITIVE AND NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARD AND
AWAY FROM THE SURFACES, RESPECTIVELY.
2. BUILDING ZONES ARE DEFINED IN ASCE 7-16 FIGURES 30.3-1, 30.3-2B, AND
30.3-5A.
3. WIND PRESSURES INDICATED ARE AT STRENGTH-LEVEL
(WIND LOAD FACTOR = 1.0).
4. WALL ZONE PRESSURES ARE SHOWN FOR STORAGE AREA. MULTIPLY
VALUES BY .87 TO OBTAIN ADMIN AREA WALL PRESSURES.
5. FOR DESIGN OF DEFLECTION-CONTROLLED COMPONENTS AND CLADDING,
DESIGN WIND PRESSURES MAY BE MULTIPLIED BY .42 TO CONVERT LOADING
TO ASD AND UTILIZE A 10-YEAR MEAN RECURRENCE INTERVAL.
-80 +32 -25 +17
-47
-57
-39
-47
3r -137 +32 -72 +17
-116 +32 -65 +17
13. COMPONENTS AND CLADDING WIND PRESSURES:
A. USE WIND PRESSURES BELOW FOR THE DESIGN OF COMPONENT AND
CLADDING ELEMENTS OR RETAIN A PROFESSIONAL ENGINEER TO
DETERMINE WIND PRESSURES FOR SPECIFIC EFFECTIVE WIND AREAS.
DESIGN WIND PRESSURES FOR ROOF COMPONENTS (PSF)
COMPONENT TRIBUTARY AREA (SQFT)
1 - 100 101+
ROOF ZONE
(ADMIN)
-40 +15 -40 +12
2' -53 -53
-47 -44
3 -62 -44
3' -88 -56
+15 +12
+15 +12
+15 +12
+15 +12
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/
/2
:0 3:
A
M C
:\U se rs \b re tt.
st od de n\
D oc um en ts \P
2-
7-
S- R
_b re tt.
st od de n.
rv t
S-001
P-
SU
BM
AR
IN
E
LO
G
IS
TI
CS
S
UP
PO
RT
F
AC
IL
IT
IE
S
ST
RU
CT
UR
AL
N
O
TE
S
AN
D
PL
AN
L
EG
EN
D
CWJ
12873738
LB/DB MTW
09/ 08/ 2022
GEOFFREY MOSS, DIRECTOR OF
WARFARE REQUIREMENTS, VIA
WMS/GKC
1704807
N4008522R2577
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
EJA
CGM
DSN
M
ID
LA
N
T D
C C
O R
E
S-
GENERAL NOTES
PLAN LEGEND
1. THE 2018 INTERNATIONAL BUILDING CODE (2018 IBC) IS THE CONSENSUS
BUILDING CODE DIRECTED FOR USE BY UNIFIED FACILITIES CRITERIA (UFC)
1-200-01 – DOD BUILDING CODE (DATED 8 OCTOBER 2019 WITH CHANGE 1, 1
OCTOBER 2020). THIS CODE IS THE PRINCIPAL BUILDING CODES OF RECORD
FOR THIS PROJECT. THE STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE
FOLLOWING SPECIFIC UNIFIED FACILITIES CRITERIA (UFC) AND RELATED DESIGN
STANDARDS:
A. UNIFIED FACILITIES CRITERIA:
1. UFC 1-200-01 (8 OCTOBER 2019, CHANGE 1, 1 OCTOBER 2020): DoD BUILDING
CODE.
2. UFC 3-301-01 (1 OCTOBER 2019): STRUCTURAL ENGINEERING
3. UFC 4-440-01 (1 APRIL 2019): WAREHOUSES AND STORAGE FACILITIES
B. SPECIFICATIONS AND STANDARDS:
1. ASCE7-16: AMERICAN SOCIETY OF CIVIL ENGINEERS, MINIMUM DESIGN LOADS
FOR BUILDINGS AND OTHER STRUCTURES
2. THIS PROJECT IS SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF
IBC 2018 AS MODIFIED BY UFC 3-301-01. THE PROJECT SPECIFICATIONS DEFINE
THE SCOPE OF SPECIAL INSPECTIONS BY THE STATEMENT AND SCHEDULE OF
SPECIAL INSPECTIONS.
3. STRUCTURAL OBSERVATIONS ARE REQUIRED FOR STRUCTURES BUT NOT FOR
WIND AND SEISMIC RESISTANCE.
4. THE STRUCTURAL SYSTEM HAS NOT BEEN DESIGNED TO RESIST
PROGRESSIVE COLLAPSE IN ACCORDANCE WITH UFC 4-023-03.
5. THE STRUCTURE MEETS THE OCCUPANCY LEVEL OF LOW OCCUPANCY
BUILDINGS. THEREFORE, THE STRUCTURAL DESIGN IS NOT REQUIRED TO
COMPLY WITH UFC 4-010-01 ANTITERRORISM PROVISIONS.
6. USE STRUCTURAL DRAWINGS IN COMBINATION WITH THE ARCHITECTURAL,
CIVIL, MECHANICAL, PLUMBING, ELECTRICAL DRAWINGS AND SPECIFICATIONS.
VERIFY AND COORDINATE THE REQUIREMENTS OF OTHER TRADES FOR
SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES AND OTHER ITEMS
INCORPORATED IN THE STRUCTURAL WORK.
7. MECHANICAL UNIT WEIGHTS AND LOCATIONS SHOWN ON THE PLANS ARE
APPROXIMATE. VERIFY LOCATIONS AND WEIGHTS, AND REPORT
DISCREPANCIES TO THE CONTRACTING OFFICER.
8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR TEMPORARY SHORING,
ERECTION BRACING, PROPER ALIGNMENT, AND SAFETY AT THE
CONSTRUCTION SITE.
9. STRUCTURAL FRAMING NOT FULLY SHOWN OR NOTED ON THE CONTRACT
DRAWINGS IS THE SAME AS AT SIMILAR FULLY DETAILED LOCATIONS SUBJECT
TO APPROVAL BY THE CONTRACTING OFFICER.
10. REPORT DIMENSIONAL DISCREPANCIES BETWEEN DRAWINGS TO THE
CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AFFECTED AREAS.
11. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND
SUPERVISION OF THE WORK ARE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
DESIGN LOADS AND CRITERIA (CONTINUED) DELEGATED ENGINEERED SYSTEMS BUILDING FOUNDATIONS
1. DESIGN RESPONSIBILITY FOR THE FOLLOWING ENGINEERED
SYSTEMS AND COMPONENT PARTS IS DELEGATED TO A QUALIFIED REGISTERED
PROFESSIONAL ENGINEER SELECTED BY THE CONTRACTOR.
A. STRUCTURAL STEEL MEMBERS AND THEIR CONNECTIONS TO THE METAL
BUILDING SYSTEM WHICH ARE NOT DESIGNED, FABRICATED AND ERECTED
BY THE METAL BUILDING SYSTEM SUPPLIER.
1. WHERE SECTIONS AND DETAILS DO NOT SHOW SPECIFIC CONNECTION
COMPONENT INFORMATION, CONNECTIONS SHOWN ARE SCHEMATIC
REPRESENTATIONS.
2. MEMBER SIZES SHOWN ARE FOR BIDDING PURPOSES ONLY.
B. CRANE RUNWAY BEAMS AND BRIDGE GIRDER FOR UNDER-HUNG CRANES
INCLUDING BEAM SPLICE CONNECTIONS, HANGERS AND LATERAL AND
LONGITUDINAL BRACING.
C. GROUND IMPROVEMENTS ELEMENTS, REFER TO GEOTECHNICAL
DRAWINGS, SHEET B-201
D. METAL BUILDING SYSTEM. REFER TO METAL BUILDING SYSTEM NOTES ON
THIS SHEET.
2. REFER TO S-001 AND S-002 FOR APPLICABLE DESIGN STANDARDS AND
CRITERIA, DESIGN LOADS AND SERVICEABILITY LIMITS.
3. INCLUDE SIGNED SEALS FOR WORK DESIGNED BY THE DELEGATED
ENGINEER.
4. DO NOT START FABRICATION OF THE DELEGATED SYSTEM OR COMPONENT
PART OR FIELD CONSTRUCTION THAT MAY BE AFFECTED BY THE SYSTEM OR
COMPONENT PART WITHOUT SUBMITTAL APPROVAL BY THE STRUCTURAL
ENGINEER OF RECORD.
10. FLOOD DESIGN DATA
A. FLOOD DESIGN CLASS 3 ASSIGNED ACCORDING TO ASCE 24
B. ELEVATION OF THE LOWEST FLOOR = 10.25
11. ROOF RAIN LOAD DATA
A. RAIN INTENSITY: i = 3.5 INCH/HOUR
12. NOTIONAL LOADS FOR GENERAL STRUCTURAL INTEGRITY:
A. LOAD PATH CONNECTIONS: 5% OF THE CONNECTED PORTION'S WEIGHT
B. LATERAL FORCES: DESIGN LATERAL FORCE APPLIED AT A STORY EQUAL
TO 1% OF THE PORTION OF THE TOTAL DEAD LOAD OF THE STRUCTURE
LOCATED OR ASSIGNED TO A LEVEL.
C. CONNECTION TO SUPPORTS: 5% OF THE UNFACTORED DEAD LOAD PLUS
LIVE LOAD REACTION IMPOSED BY THE SUPPORTED MEMBER ON THE
SUPPORTING MEMBER.
D. ANCHORAGE OF STRUCTURAL WALLS: STRENGTH LEVEL HORIZONTAL
FORCE PERPENDICULAR TO THE PLANE OF THE WALL EQUAL TO 20% OF
THE WEIGHT OF THE WALL TRIBUTARY TO THE CONNECTION, BUT NOT
LESS THAN 5 PSF.
5. BRIDGE CRANE: POWERED 5 TON SINGLE GIRDER, UNDER RUNNING, PENDANT-
OPERATED (LIVE LOADS ARE BASED ON RATED LOAD = 10,000 LBS)
A. VERTICAL WHEEL LOADS W/O IMPACT INCREASE:
a. DEAD LOAD: 2600 LBS PER WHEEL
b. LIVE LOAD: 5000 LBS PER WHEEL
B. LATERAL FORCE
a. DEAD LOAD: 300 LB
b. LIVE LOAD: 2000 LB
C. LONGITUDINAL FORCE:
a. DEAD LOAD: 520 LBS PER RAIL
b. LIVE LOAD: 1000 LBS PER RAIL
D. VERTICAL IMPACT FORCE: 10 PERCENT OF VERTICAL WHEEL DEAD PLUS
LIVE LOAD
E. CMAA #74/ MH27.1 SERVICE CLASS: C
6. ROOF SNOW LOAD
A. GROUND SNOW LOAD: Pg = 10 PSF
B. FLAT-ROOF SNOW LOAD: Pf = 7.6 PSF
C. SNOW EXPOSURE FACTOR: Ce = .9 FOR PARTIALLY EXPOSED AT TERRAIN
CATEGORY D
D. SNOW LOAD IMPORTANCE FACTOR: IS = 1.0
E. THERMAL FACTOR: Ct = 1.0
F. SLOPE FACTOR: Cs 1.0
7. WIND DESIGN CRITERIA
A. BASIC DESIGN WIND SPEED: 118 MPH
B. ALLOWABLE STRESS DESIGN WIND SPEED: 91 MPH
C. WIND EXPOSURE CATEGORY: D
D. INTERNAL PRESSURE COEFFICIENT: +/- 0.18
E. ENCLOSURE CLASSIFICATION: ENCLOSED
F. TOPOGRAPHIC FACTOR: 1.0
G. THE MAIN WIND FORCE-RESISTING SYSTEM (MWFRS) IS THE SEISMIC
FORCE-RESISTING SYSTEM (SFRS) DESCRIBED IN THE SEISMIC DESIGN
CRITERIA.
8. OVERHEAD COILING DOOR CRITERIA
A. THE OVERHEAD COILING DOOR MUST BE PRESSURE TESTED FOR THE
COMPONENT AND CLADDING WIND PRESSURE OF 20 PSF (ALLOWABLE
STRESS DESIGN, SERVICE LEVEL) AND SHOWN TO PASS IN ACCORDANCE
WITH ANSI/DASMA 108, STANDARD METHOD FOR TESTING SECTIONAL
GARAGE DOORS AND ROLLING DOORS.
9. SEISMIC DESIGN DATA
A. SEISMIC IMPORTANCE FACTOR: Ie = 1.0
B. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS:
a. SS = .089g, S1 = 0.04g PER WBDG STRUCTURAL LOAD DATA TOOL
C. SITE CLASS: D
D. SHORT-PERIOD SITE COEFFICIENT: Fa = 1.6
E. LONG-PERIOD SITE COEFFICIENT: Fv = 2.4
F. DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS:
a. SDS = 0.095g, SD1 = 0.064g
G. SEISMIC DESIGN CATEGORY: A
H. BASIC SEISMIC FORCE-RESISTING SYSTEM: COMPRISED OF BRACED
FRAMES AND MOMENT FRAMES NOT SPECIFICALLY DETAILED FOR SEISMIC
RESISTANCE
I. SEISMIC RESPONSE COEFFICIENT: Cs = 0.0397
J. RESPONSE MODIFICATION COEFFICIENT: R = 3
K. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE ANALYSIS
L. THE ASCE 7-16 SEISMIC DESIGN REQUIREMENTS FOR BUILDINGS DO NOT
APPLY TO THIS BUILDING SINCE IT HAS BEEN ASSIGNED TO SEISMIC DESIGN
CATEGORY A.
SERVICEABILITY LIMITS
1. DEFLECTION LIMIT FOR STRUCTURAL MEMBERS SUPPORTING ROOFING.
WIND INDUCED DEFLECTION LIMITS FOR ROOF FRAMING MEMBERS BASED ON
0.42 TIMES THE BASIC COMPONENT AND CLADDING LOADS:
A. LIVE LOAD: L/240
B. DEAD LOAD + LIVE LOAD: L/180
C. WIND OR SNOW LOAD: L/240
2. DEFLECTION LIMIT FOR CRANE MEMBERS:
(W/O IMPACT LOADS)
A. VERTICAL
a. CRANE GIRDER: L/600 (BASED ON RATED LOAD + TROLLEY/HOIST DL +
GIRDER SELF WEIGHT)
b. CRANE RUNWAY: L/450 (BASED ON MAXIMUM VERTICAL WHEEL LOADS)
B. LATERAL: L/400 (BASED ON 10% OF MAX VERTICAL WHEEL LOAD)
3. BUILDING LATERAL DRIFT: H/320 BASED ON AN ALLOWABLE STRESS DESIGN
WIND SPEED WITH A 10 YEAR MEAN RECURRENCE INTERVAL.
4. WIND INDUCED DEFLECTION LIMITS FOR FRAMING SUPPORTING EXTERIOR
WALL FINISHES BASED ON 0.42 TIMES THE BASIC COMPONENT AND
CLADDING LOADS:
A. L/240 FOR METAL SIDING
B. L/600 FOR MASONRY
5. SHALLOW FOUNDATION SETTLEMENT MUST NOT EXCEED 1/2-INCH BETWEEN
ADJACENT COLUMN LINES, 1 INCH TOTAL, OR ANGULAR DISTORTION OF 1/500.
6. FLOOR SLAB SETTLEMENT MUST NOT EXCEED 1/2" POST CONSTRUCTION.
1. THE INFORMATION PROVIDED IN THE GEOTECHNICAL DESIGN MEMORANDUM
PREPARED BY NAVFAC MID-ATLANTIC TITLED “P-702 SUBMARINE LOGISTICS
SUPPORT FACILITIES NAVAL STATION NORFOLK, NORFOLK, VA” DATED 08
MARCH 2022 HAS BEEN USED FOR THE DESIGN OF THE FOUNDATIONS.
2. SITE PREPARATION
A. PERFORM GROUND IMPROVEMENTS AND PRELOADING IN ACCORDANCE
WITH SHEET B-201 OF THE CONTRACT DRAWINGS AND SPECIFICATION
SECTION 31 62 50 (GROUND IMPROVEMENT ELEMENTS).
3. SOIL AND SITE CHARACTERISTICS
A. MODULUS OF SUBGRADE REACTION: 150 PCI FOR SLAB ON GRADE BEARING
UPON WELL-COMPACTED STRUCTURAL FILL MATERIAL.
B. FROST PENETRATION: 9 INCHES
4. NET ALLOWABLE SOIL BEARING PRESSURE OF 3000 PSF FOR SHALLOW
FOUNDATIONS AT MBS COLUMNS.
5. NET ALLOWABLE SOIL BEARING PRESSURE OF 1500 PSF FOR SHALLOW
FOUNDATIONS AT SITE RETAINING WALLS.
6. EXCAVATE, FILL, AND BACKFILL IN ACCORDANCE WITH THE CONTRACT
DRAWINGS AND SPECIFICATIONS.
7. COORDINATE FOUNDATION WORK WITH ADJACENT UNDERGROUND UTILITIES
AND STRUCTURES. DO NOT PLACE FOUNDATIONS PRIOR TO SUCH
COORDINATION.
8. PROVIDE UTILITIES PERPENDICULAR TO WALL FOOTINGS. DO NOT PLACE
UTILITIES UNDER COLUMN FOOTINGS.
9. LOWER FOOTINGS TO PASS UNDER UTILITY LINES. ALTERNATIVELY, PROVIDE
PIPE SLEEVES BELOW OR THROUGH CONTINUOUS FOOTINGS IN ACCORDANCE
WITH THE TYPICAL DETAILS ON DRAWING SB501. FOOTING STEPS, WHERE
INDICATED ON PLAN, ARE SCHEMATIC AND MUST BE COORDINATED WITH
OTHER TRADES.
10. PRIOR TO PLACING FOUNDATION REINFORCEMENT AND CONCRETE, THE
FOOTING SUBGRADE MUST BE INSPECTED BY THE SPECIAL INSPECTOR, A
GEOTECHNICAL ENGINEER, FOR LOOSE, SOFT, EXPANSIVE, OR OTHERWISE
UNSUITABLE MATERIALS. WHEN REQUIRED, THE GEOTECHNICAL ENGINEER
MUST PROVIDE DIRECTION FOR CORRECTIVE ACTIONS, SUBJECT TO REVIEW
AND APPROVAL OF THE CONTRACTING OFFICER.
11. DO NOT PLACE UNBALANCED BACKFILL AGAINST MASONRY OR CONCRETE
WALLS UNLESS WALLS ARE SECURELY BRACED AGAINST OVERTURNING BY
PERMANENT OR TEMPORARY CONSTRUCTION BRACING.
12. FACTOR OF SAFETY AGAINST OVERTURNING AND SLIDING ARE 1.5 AND 2.0,
RESPECTIVELY. FACTORS OF SAFETY ARE BASED ON NOMINAL LOADS.
DESIGN LOADS AND CRITERIA
1. RISK CATEGORY: II PER UFC 3-301-01 TABLE 2-2.
2. LIVE LOADS PER UFC 3-301-01 TABLE G-1
A. UNIFORM ROOF LIVE LOAD 20 PSF
B. CONCENTRATED ROOF LOAD 300 LBS
C. GROUND FLOOR SLAB:
STORAGE: 300 PSF
MECHANICAL ROOMS: 150 PSF
ELECTRICAL ROOMS: 150 PSF
FIRE PUMP ROOMS: 150 PSF
ALL OTHER AREAS: 100 PSF
A. CONCENTRATED LOAD: 9,000 LBS UNIFORMLY DISTRIBUTED OVER AN
AREA 2.5 FEET BY 2.5 FEET AT ALL FLOOR AREAS
(UNIFORM AND CONCENTRATED LIVE LOADS HAVE NOT BEEN APPLIED
CONCURRENTLY)
B. FORKLIFT: 7.5 TON CAPACITY PNEUMATIC TIRE FORKLIFT
C. AASHTO TRUCK LOADING: HS20-44
4. DEAD LOADS:
A. SELF WEIGHT OF MATERIALS
B. COLLATERAL DEAD LOAD = 10 PSF
DESIGN LOADS AND CRITERIA (CONTINUED)
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
AM
E N
DM
EN
T
0 0
/29
/23
WALL FOOTING AT UTILITY LINES
UTILITY PERPENDICULAR TO AND BELOW FOOTING
STEPPED CONTINUOUS FOOTING (SF)
M
AX
8"
M
IN
" M
AX
8"
M
IN
8" STEP
16" MIN
16" STEP
32" MIN
3" CLEAR
12" MIN
LAP (TYPICAL)
36 BAR DIAMETER
CONTINUOUS WALL FOOTING
REINFORCEMENT
CONTINUOUS WALL
FOOTING
REINFORCEMENT
'Z' BARS SAME SIZE
AND NUMBER AS
CONTINUOUS FOOTING
REINFORCEMENT,
BEND AS SHOWN
" M
AX
4"
M
IN
(TYPICAL)
12" MIN
" M
IN
1500 PSI LEAN
CONCRETE, WIDTH
EQUAL TO CONTINUOUS
FOOTING WIDTH,
PLACED BEFORE
FOOTING IS PLACED
NON-CORROSIVE
METAL PIPE SLEEVE
(INSIDE Ø = OUTSIDE
PIPE Ø + 2" MIN)
CONTINUOUS
WALL FOOTING
CONTINUOUS
REINFORCEMENT
UTILITY PERPENDICULAR TO AND THROUGH FOOTING
NON-CORROSIVE METAL
PIPE SLEEVE (INSIDE Ø =
OUTSIDE PIPE Ø + 2" MIN)
ADDED BARS SAME SIZE AND NUMBER
AS CONTINUOUS REINFORCEMENT
CONTINUOUS
BOTTOM
REINFORCEMENT,
CUT AT PIPE SLEEVE
AS REQUIRED
6" M
IN
(TYPICAL)2" CLEAR
" M
IN
12" MIN
#4 AT 12" OC
(1) #4
(1) #4
STANDARD 90°
HOOK (TYPICAL)
3" C
LE
AR
(T
YP
IC
AL
2"
C
LE
AR
CONTINUOUS WALL
FOOTING, REFER TO
PLAN
TOP OF SLEEVE WITHIN FOOTING OR LESS
THAN 4" FROM BOTTOM OF FOOTING
9"
MIN
1' - 6"
UTILITY PARALLEL TO FOOTING
BACKFILL
PIPE/CONDUIT IN TRENCH
NO TRENCH EXCAVATION
PARALLEL TO FOOTING BELOW
THIS LINE. STEP FOOTING PER
DETAIL TO ENSURE LINE IS
BELOW EXCAVATION
9"
NO TRENCH EXCAVATION
PARALLEL TO FOOTING BELOW
THIS LINE. STEP FOOTING PER
DETAIL TO ENSURE LINE IS
BELOW EXCAVATION
WHEN PIPE/CONDUIT TRENCH FALLS
BELOW THE 2:1 PLANE BUT IS
ABOVE THE 1:1 PLAN, FILL TRENCH
WITH 1500 PSI LEAN CONCRETE
NOTES:
1. IN LIEU OF THESE DETAILS, FOOTINGS MAY BE LOWERED TO PASS UNDER UTILITY LINES ACCORDING TO THE TYPICAL STEPPED CONTINUOUS FOOTING DETAIL ON THIS SHEET.
2. PERPENDICULAR PIPE SLEEVE THROUGH / BELOW FOOTING MUST EXTEND TO EDGE OF 1:1 BEARING ZONE ON EACH SIDE OF FOOTING UNLESS OTHERWISE NOTED.
3. IF UTILITY LINE IS IN PLACE PRIOR TO PLACING CONCRETE, WRAP UTILITY WITH 1" THICK COMPRESSIBLE MATERIAL BEFORE PLACING CONCRETE IN LIEU OF SLEEVE.
4. FOR UTILITIES BELOW FOOTING WHERE CONCRETE ENCASEMENT IS NOT FEASIBLE, DESIGN PIPE AND PIPE JOINTS TO ADEQUATELY RESIST ALL SUPERIMPOSED LOADS
INCLUDING SOIL SURCHARGE PRESSURES.
2" C
LR
EQ
EQ
3"
3" CLR
VERTICAL DOWELS WITH
STANDARD 90-DEGREE
HOOK TOP AND BOTTOM
COLUMN, BASE PLATE, AND
ANCHOR RODS BY
BUILDING MANUFACTURER
COLUMN FOOTING
CONCRETE PEDESTAL
REFER TO PLAN AND
SCHEDULE
TRANSVERSE TIES
REFER TO
SCHEDULE FOR
SIZE AND SPACING
2" C
LR
COLUMN, BASE PLATE, AND
ANCHOR RODS BY
BUILDING MANUFACTURER
COLUMN FOOTING
(4) #6 DOWELS WITH STD
90-DEGREE HOOK TOP
AND BOTTOM
PIER REINFORCING ANCHOR REINFORCING
3" 1"
6" MAX
A
CONCRETE
PEDESTAL REFER TO
PLAN AND SCHEDULE
A A A
ASSUMED ANCHOR
LOCATIONS
(COORD WITH MBS MFR)
FACE OF BUILDING / STEEL LINE
EM
BE
DM
EN
T = 1
3"
3" C
LR
(T
YP
3"
ADJUST REINFORCING
AS REQUIRED TO AVOID
ANCHOR RODS
NOTE: ANCHOR ROD EMBEDMENT LENGTH = 18". LENGTH MAY BE
ADJUSTED BASED ON REVIEW OF MBS FOUNDATION REACTIONS.
2"
NON-SHRINK GROUT
TYP AT BASE PLATES
SECTION A-A
AT COLUMN FOOTING
REF PLAN
TOF
EXTERIOR WALL 4'
-0
DOME
PIPE6STD (GALV), FILL
BOLLARD WITH 4000
PSI CONCRETE
1/2" PREMOLDED JOINT
FILLER ALL AROUND
SLAB-ON-GRADE,
REINF NOT SHOWN
CONCRETE FOOTINGSECTION B-B
B B
8" 8"
1' - 4" 1/4
TYP EA
STIFFENER
3/8 PJP
PIPE6STD (GALV), FILL
BOLLARD WITH 4000 PSI
CONCRETE
3/8PJP
(8) 3/4"Ø EPOXY
ADHESIVE ANCHORS,
8" MIN EMBEDMENT
IN CONCRETE BASE
MATERIAL
(4) PL3/8X5X2 STIFFENER
PL1-1/2X16X16
1"
8"
6 1 /2"
1/4TYP
CONCRETE BOND BREAK
MATERIAL AROUND
STEEL BOLLARD
ASSEMBLY, TYP
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/
/2
:0 3:
A
M C
:\U se rs \b re tt.
st od de n\
D oc um en ts \P
2-
7-
S- R
_b re tt.
st od de n.
rv t
SB501
P-
SU
BM
AR
IN
E
LO
G
IS
TI
CS
S
UP
PO
RT
F
AC
IL
IT
IE
S
FO
UN
DA
TI
O N
DE
TA
IL
S
CWJ
12873743
LB/DB MTW
09/ 08/ 2022
GEOFFREY MOSS, DIRECTOR OF
WARFARE REQUIREMENTS, VIA
WMS/GKC
1704807
N4008522R2577
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
EJA
CGM
DSN
M
ID
LA
N
T D
C C
O R
E
SB
1" = 1'-0"A1 TYPICAL FOOTING DETAILS
COLUMN FOOTING SCHEDULE
MARK
DIMENSIONS
REINFORCING STEELWIDTH LENGTH DEPTH
CF5.5 5' - 6" 5' - 6" 1' - 4" (6)-#5 EACH DIRECTION TOP AND BOTTOM
CF6.0 6' - 0" 6' - 0" 1' - 4" (7)-#5 EACH DIRECTION TOP AND BOTTOM
CF7.0 7' - 0" 7' - 0" 1' - 4" (8)-#6 EACH DIRECTION TOP AND BOTTOM
CONCRETE PEDESTAL SCHEDULE
MARK
DIMENSIONS REINFORCING
W D VERTICAL TIES
P-1 36" 36" (12) #7 #4 AT 8" ON CENTER,
MAX
P-2 32" 32" (12) #6 #4 AT 8" ON CENTER,
MAX
P-3 32" 26" (12) #7 #4 AT 8" ON CENTER,
MAX
P-4 44" 32" (12) #7 #4 AT 8" ON CENTER,
MAX
1" = 1'-0"C1 TYPICAL COLUMN PIER ON FOOTING
WALL FOOTING SCHEDULE
MARK
DIMENSIONS
REINFORCINGWIDTH DEPTH
WF3.0 3' - 0" 1' - 4" (3)-#5 CONTINUOUS TOP AND BOTTOM WITH #4 SUPPORT BARS AT 4'-0" ON CENTER WF4.0 4' - 0" 1' - 4" (3)-#5 CONTINUOUS TOP AND BOTTOM WITH #4 SUPPORT BARS AT 4'-0" ON CENTER
1" = 1'-0"C4 BOLLARD DETAIL
1' 2'0' 6"
1' 2'0' 6"1' 2'0' 6"
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
AM
E N
DM
EN
T
0 0
/29
FINISHED GRADE
0' - 0"
ROOF
32' - 10"
A E F
45' - 0"
SF301
C3
9' - 6"
CR
AN
E
HO
OK
H
EI
GH
T
CRANE CLEAR LIMIT LINE
(BOTTOM OF RUNWAY BEAM)
4'
- 4
" M
AX
62' - 4"
9' - 6"
21' - 5"
8"
6" M
IN
8' - 0"
CR
AN
E
CL
EA
R
HE
IG
HT
6"
2' - 0"
CRANE STOP (TYP)
COORDINATE CRANE
STOP DETAIL AND
LOCATIONS WITH
HOIST MFR
CRANE STOP (TYP)
10"
MBS STEEL LINE
10"
MBS STEEL LINE
- TOP OF EAVE STRUT
FAN SUPPORT FRAMING
BY HVLS FAN MFR,
REFER TO MECH DWGS
6" MIN FACE OF COLUMN
TO BRIDGE GIRDER
COORDINATE BRIDGE
GIRDER LENGTH WITH MBS
7' - 6"
BRIDGE GIRDER BY
CRANE MFR
RUNWAY HANGER
BY CRANE MFR CRANE RUNWAY BY CRANE MFR
RIGGING (NIC)
WF FAN SUPPORT FRAMING BY MBS MFR
COORD WITH HVLS FAN MFR
10" MINIMUM PURLIN
DEPTH TYP
C4
SB402
HOOK COVERAGE
5' - 8" ±
1' - 6" 5' - 8" ±
4' - 0" MAX
8" 2'
- 0
CR
AN
E
HO
OK
T
RA
VE
L D
IS
TA
NC
E
CRANE SUPPORT HANGER
(RIGID OR FLEXIBLE) LATERAL
AND LONGITUDINAL BRACING
TO STRUCTURE BY CRANE
MANUFACTURER
STIFFENER PLATE BY MBS MFR
COORD W/ CRANE MFR
REFER TO BRIDGE CRANE
NOTES FOR CRANE REACTIONS
TO SUPPORTING STRUCTURE
MA
X
L = L
+ A
MI
N
L = L
- A
NO
MI
NA
L S
PA
N
L
+B
-B
+C
-C
CRANE SPAN
(L)
MEASURED AT CRANE
WHEEL CONTACT
SURFACE
STRAIGHTNESS
(B)
ELEVATION
(C)
A = 3/16" 1/4" IN 20'-0"
1/4" IN 20'-0"B = 3/8"
1/4" IN 20'-0"C = 3/8"
ITEM FIGURE OVERALL
TOLERANCE
MAXIMUM RATE
OF CHANGE
SUPPORT POINTS, TYP
CL WEB
THEORETICAL CL
CL WEB
TOP OF BEAM
SUPPORT POINTS, TYP
THEORETICAL HEIGHT
D
UNDERHUNG
1/4" IN 20'-0"D = 3/8"
BEAM TO BEAM
UNDERHUNG
(D)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/
/2
:0 3:
A
M C
:\U se rs \b re tt.
st od de n\
D oc um en ts \P
2-
7-
S- R
_b re tt.
st od de n.
rv t
SF301
P-
SU
BM
AR
IN
E
LO
G
IS
TI
CS
S
UP
PO
RT
F
AC
IL
IT
IE
S
CR
AN
E
SE
CT
IO
NS
CWJ
12873749
LB/DB MTW
09/ 08/ 2022
GEOFFREY MOSS, DIRECTOR OF
WARFARE REQUIREMENTS, VIA
WMS/GKC
1704807
N4008522R2577
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
EJA
CGM
DSN
M
ID
LA
N
T D
C C
O R
E
SF
0' 4' 8' 12'
0' 1' 2' 3'
3/16" = 1'-0" (SB101)A1 SECTION
3/4" = 1'-0" (SF301)C3 SECTION
NOT TO SCALEC1 BRIDGE CRANE TOLERANCE DIAGRAMS
BRIDGE CRANE NOTES
1. REFER TO SHEET S-001 FOR OVERHEAD BRIDGE CRANE DESIGN LOADS.
2. REFER TO PLAN AND ELEVATIONS FOR LOCATION OF CRANE, CRANE
BEAMS AND CRANE STOPS.
3. AT SPLICES OF RUNWAY SECTIONS, FLAT PLATES MUST BE USED ON BOTH
SIDES OF THE UPPER T-SECTION WEBS. THE LOWER T-SECTION ENDS
MUST BE ALIGNED TO MINIMIZE THE HORIZONTAL GAP ON THE RUNNING
SURFACE TO NOT GREATER THAN 1/16" AND NOT GREATER THAN A
VERTICAL DIFFERENCE OF 1/32" FOR THE WHEEL RUNNING SURFACE
ALIGNMENT FOR A SMOOTH CROSSING BY THE WHEELS.
4. PERFORM A VERTICAL AND HORIZONTAL ALIGNMENT SURVEY OF THE
CRANE RAIL SYSTEM FOLLOWING INSTALLATION PERFORMED BY A
LICENSED SURVEYOR. PROVIDE THE CRANE RAIL SYSTEM PER
TOLERANCES INDICATED IN "BRIDGE CRANE TOLERANCE DIAGRAMS" ON
THIS SHEET. FOLLOWING INSTALLATION AND ADJUSTMENT OF THE CRANE
RAIL SYSTEM, SUBMIT A REPORT TO THE CONTRACTING OFFICER. THE
REPORT (2 COPIES) MUST INCLUDE, DATE OF CRANE RAIL SYSTEM
INSTALLATION, ALL SURVEY NOTES (INITIAL, INTERMEDIATE, AND FINAL).
5. ESTIMATED REACTIONS FROM CRANE SUPPORT HANGER TO MBS MAIN
FRAME BEAM:
VERTICAL DL = 7,400 LB
VERTICAL LL = 10,000 LB
LONGITUDINAL DL = 520 LB
LONGITUDINAL LL = 1000 LB
LATERAL DL = 150 LB
LATERAL LL = 1000 LB
NOTES:
A. LOADS SHOWN DO NOT INCLUDE IMPACT FACTORS
B. LONGITUDINAL LOADS ACT PERPENDICULAR TO MAIN FRAME BEAM
C. LATERAL LOADS ACT PARALLEL TO MAIN FRAME BEAM
D. ACTUAL CRANE DATA, TO INCLUDE CRANE STOP FORCES, HANGER AND
BRACING CONFIGURATION MUST BE OBTAINED FROM CRANE SUPPLIER
AND COORDINATED WITH MBS DESIGNER.
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
AM
E N
DM
EN
T
0 0
/29
| S-001 - STRUCTURAL NOTES AND PLAN LEGEND |
| SB501 - FOUNDATION DETAILS |
| SF301 - CRANE SECTIONS |