View the file

Other files

File Type Posted
Amendment 0018.pdf PDF
Amendment 0017.pdf PDF
Amendment 0016.pdf PDF
Amendment 0016 Revised Drawings.pdf PDF
Amendment 0016 Revised Specifications.pdf PDF
Amendment 0015.pdf PDF
Amendment 0014.pdf PDF
P702 JA Interior Finishes_redacted.pdf PDF
CU502_revised.pdf PDF
CM102_revised.pdf PDF
Amendment 0013.pdf PDF
Amendment 0012.pdf PDF
08 11 13_revised.pdf PDF
Amendment 0011.pdf PDF
Amendment 0010.pdf PDF
07 42 13 METAL WALL PANELS - Amendment 0010.pdf PDF
41 22 13 15_Rev1.pdf PDF
13 34 19_Rev1.pdf PDF
P702 Structural Drawings.pdf PDF
Attachment E - Price Proposal Form Seed Project revised.docx DOCX document
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Final FFE Package.pdf PDF
CIVIL SHEETS 007.pdf PDF
MECH SHEETS 0007.pdf PDF
P702-1704807-ELEC DWGS.pdf PDF
P702-1704807-CIVIL DWGS.pdf PDF
P702-Geotechnical Data Report.pdf PDF
VNG Natural Gas Line Agreement.pdf PDF
Gate 6 Site Characterization Report.pdf PDF
Amendment 0006.pdf PDF
P702-1704807 MECH DWG.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
23R2562 P702 Site Visit Log.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment H - P702 Drawings.pdf PDF
P702 Specifications Amendment Section 01 50 00.pdf PDF
Attachment I - Approved Identity Proofing Documents.pdf PDF
N4008523R2562 SB MACC HR GEN CONSTR.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment K - SECNAV 5512.pdf PDF
Attachment G - P702 Specifications.pdf PDF
Attachment E - Price Proposal Form Seed Project.docx DOCX document
Attachment J - Criteria for Denying Access to Navy Installations.pdf PDF
Attachment A - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOWNSPOUT SEE PLANS

FOR SIZE

8" M

IN

DOWNSPOUT STRAP

ANCHOR

FACE OF BUILDING

CAST IRON DOWNSPOUT

BOOT

AIR BREAK - DO NOT SEAL

MOUNTING BRACKET PER

BOOT MANUFACTURER

STORM DRAINAGE -

SEE CIVIL DRAWINGS

INSTALL NECESSARY

FITTINGS TO CONNECT

TO UNDERGROUND

STORM LINES

LINE OF FOUNDATION - SEE

STRUCTURAL DRAWINGS

GROUT SEAT

4"

2 1 /2"

3 3 /4"

8 1/2"

SELF ADHEREING AIR

BARRIER (AB-2) TRANSITION

MEMBRANE AT CMU METAL

PANEL TRANSITION

PREFINISHED

METAL FLASHING

4" SPLIT

FACE CMU

RIGID

INSULATION

GLAV METAL

COUNTER FLASHING

8" CMU BLOCK

SEE STRUCT.

2" AIR GAP

METAL

WALL PANEL

AIR BARRIER- PERMEABLE SHEET BY MBS

INSULATION MANUFACTUCER

LINER SYSTEM BY INSULATION MANUFACTER,

CONTINOUS. TERMINATE PER MANUFACTERES

INSTRUCTIONS

FLUID APPLIED

AIR BARRIER (AB-1)

MBS INSULATION

AIR BARRIER (AB-3)

4"

2 1 /2"

3 3 /4"

8 1/2"

METAL

WALL PANEL

FLUID APPLIED AIR

BARRIER TRANSITION

MEMBRANE

PREFINISHED

METAL FLASHING

4" SPLIT

FACE CMU

3" RIGID

INSULATION

GLAV METAL

COUNTER FLASHING

8" CMU BLOCK

2" AIR GAP FLUID APPLIED

AIR BARRIER (AB-1)

4" SPLIT FACE CMU

PARTITION TYPE M1

R12 BOARD INSULATION

LADDER TYPE HORIZ.

JOINT REINF. W/ ADJUSTABLE

BRICK TIES AT 1'-4" OC

VERTICALLY BEGINNING 8" A.F.F.

1'-7 1/4"

2" AIR GAP

FLUID APPLIED AIR BARRIER (AB-1)

PARTITION TYPE M1

R12 BOARD INSULATION

7/8" AIR GAP

METAL WALL PANEL

SEE WALL SECTION

FLUID APPLIED

AIR BARRIER (AB-1)

7/8" HAT CHANNEL; 16 GAUGE

GALVANIZED; INSTALL

HORIZONTALLY; 2'8" OC MAX.

COMPOSITE Z-GIRT; 2 1/2" DEEP +/- ;

INSTALL VERTICALLY; 24" OC;

COORDINATE DEPTH OF Z-GIRT WITH

THICKNESS OF INSULATION

4" SPLIT FACE CMU

3' RIGID INSULATION AIR BARRIER TRANSITION

MEMBRANE, LAP OVER THRU WALL FLASHING

FLUID APPLIED

AIR BARRIER (AB-1)

THROUGH WALL FLASHING, TUCK

FLASHING INTO MORTAR JOINT

2" AIR GAP

CAVITY FILTER MORTAR

COLLECTION DEVICE

WEEPS @ 32" O.C. AND

PREFORMED VIYNL INSERT

GROUT CAVITY SOLID TO

UNDERSIDE OF FLASHING

8" CMU

REINFORCED CONCRETE SLAB,

SEE STRUCTURAL DRAWINGS

CONTINUOUS VAPOR

RETARDER UNDER SLAB

PERIMETER INSULATION

2'- 0"

T

OF

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 5/

:2

5:

P M

P7

-1

-A -R

_d et ac he d.

rv t

AE502

P-

SU

BM

AR

IN

E

LO

G

IS

TI

CS

S

UP

PO

RT

F

AC

IL

IT

IE

S

EX

TE

RI

O

R

DE

TA

IL

S

MGC

12873768

GKC CEW

09/ 08/ 2022

GEOFFREY MOSS, DIRECTOR OF

WARFARE REQUIREMENTS, VIA

EMAIL

WMS/GKC

1704807

N4008522R2577

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

EJA

CGM

DSN

M

ID

LA

N

T D

C C

O R

E

AE

3" = 1' - 0" 0 3" 6" 1'

1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"

GRAPHIC SCALE(S)

SCALE: 1 1/2" = 1'-0"A5 DOWNSPOUT BOOT DETAIL

SCALE: 3" = 1'-0" (AE302)B1 WALL DETAIL @ STUD

SCALE: 3" = 1'-0" (AE302)A1 WALL DETAIL @ CMU

SCALE: 1 1/2" = 1'-0"C1 TYPICAL EXTERIOR WALL DETAIL @ CMU

SCALE: 1 1/2" = 1'-0"C2 TYPICAL EXTERIOR WALL DETAIL @ METAL PANEL

SCALE: 1 1/2" = 1'-0" (AE302)A3 WALL DETAIL @ SLAB

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

W

AL

L P

AN

EL

C

ON

NE

CT

OR

R

EV

IS

IO

N

7/5 /23

Sheets
AE502 - EXTERIOR DETAILS

File details come from the government source that posted it. Updated .