DOWNSPOUT SEE PLANS
FOR SIZE
8" M
IN
DOWNSPOUT STRAP
ANCHOR
FACE OF BUILDING
CAST IRON DOWNSPOUT
BOOT
AIR BREAK - DO NOT SEAL
MOUNTING BRACKET PER
BOOT MANUFACTURER
STORM DRAINAGE -
SEE CIVIL DRAWINGS
INSTALL NECESSARY
FITTINGS TO CONNECT
TO UNDERGROUND
STORM LINES
LINE OF FOUNDATION - SEE
STRUCTURAL DRAWINGS
GROUT SEAT
4"
2 1 /2"
3 3 /4"
8 1/2"
SELF ADHEREING AIR
BARRIER (AB-2) TRANSITION
MEMBRANE AT CMU METAL
PANEL TRANSITION
PREFINISHED
METAL FLASHING
4" SPLIT
FACE CMU
RIGID
INSULATION
GLAV METAL
COUNTER FLASHING
8" CMU BLOCK
SEE STRUCT.
2" AIR GAP
METAL
WALL PANEL
AIR BARRIER- PERMEABLE SHEET BY MBS
INSULATION MANUFACTUCER
LINER SYSTEM BY INSULATION MANUFACTER,
CONTINOUS. TERMINATE PER MANUFACTERES
INSTRUCTIONS
FLUID APPLIED
AIR BARRIER (AB-1)
MBS INSULATION
AIR BARRIER (AB-3)
4"
2 1 /2"
3 3 /4"
8 1/2"
METAL
WALL PANEL
FLUID APPLIED AIR
BARRIER TRANSITION
MEMBRANE
PREFINISHED
METAL FLASHING
4" SPLIT
FACE CMU
3" RIGID
INSULATION
GLAV METAL
COUNTER FLASHING
8" CMU BLOCK
2" AIR GAP FLUID APPLIED
AIR BARRIER (AB-1)
4" SPLIT FACE CMU
PARTITION TYPE M1
R12 BOARD INSULATION
LADDER TYPE HORIZ.
JOINT REINF. W/ ADJUSTABLE
BRICK TIES AT 1'-4" OC
VERTICALLY BEGINNING 8" A.F.F.
1'-7 1/4"
2" AIR GAP
FLUID APPLIED AIR BARRIER (AB-1)
PARTITION TYPE M1
R12 BOARD INSULATION
7/8" AIR GAP
METAL WALL PANEL
SEE WALL SECTION
FLUID APPLIED
AIR BARRIER (AB-1)
7/8" HAT CHANNEL; 16 GAUGE
GALVANIZED; INSTALL
HORIZONTALLY; 2'8" OC MAX.
COMPOSITE Z-GIRT; 2 1/2" DEEP +/- ;
INSTALL VERTICALLY; 24" OC;
COORDINATE DEPTH OF Z-GIRT WITH
THICKNESS OF INSULATION
4" SPLIT FACE CMU
3' RIGID INSULATION AIR BARRIER TRANSITION
MEMBRANE, LAP OVER THRU WALL FLASHING
FLUID APPLIED
AIR BARRIER (AB-1)
THROUGH WALL FLASHING, TUCK
FLASHING INTO MORTAR JOINT
2" AIR GAP
CAVITY FILTER MORTAR
COLLECTION DEVICE
WEEPS @ 32" O.C. AND
PREFORMED VIYNL INSERT
GROUT CAVITY SOLID TO
UNDERSIDE OF FLASHING
8" CMU
REINFORCED CONCRETE SLAB,
SEE STRUCTURAL DRAWINGS
CONTINUOUS VAPOR
RETARDER UNDER SLAB
PERIMETER INSULATION
2'- 0"
T
OF
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
7/ 5/
:2
5:
P M
P7
-1
-A -R
_d et ac he d.
rv t
AE502
P-
SU
BM
AR
IN
E
LO
G
IS
TI
CS
S
UP
PO
RT
F
AC
IL
IT
IE
S
EX
TE
RI
O
R
DE
TA
IL
S
MGC
12873768
GKC CEW
09/ 08/ 2022
GEOFFREY MOSS, DIRECTOR OF
WARFARE REQUIREMENTS, VIA
WMS/GKC
1704807
N4008522R2577
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
EJA
CGM
DSN
M
ID
LA
N
T D
C C
O R
E
AE
3" = 1' - 0" 0 3" 6" 1'
1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"
GRAPHIC SCALE(S)
SCALE: 1 1/2" = 1'-0"A5 DOWNSPOUT BOOT DETAIL
SCALE: 3" = 1'-0" (AE302)B1 WALL DETAIL @ STUD
SCALE: 3" = 1'-0" (AE302)A1 WALL DETAIL @ CMU
SCALE: 1 1/2" = 1'-0"C1 TYPICAL EXTERIOR WALL DETAIL @ CMU
SCALE: 1 1/2" = 1'-0"C2 TYPICAL EXTERIOR WALL DETAIL @ METAL PANEL
SCALE: 1 1/2" = 1'-0" (AE302)A3 WALL DETAIL @ SLAB
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
W
AL
L P
AN
EL
C
ON
NE
CT
OR
R
EV
IS
IO
N
7/5 /23