View the file

Other files

File Type Posted
Amendment 0018.pdf PDF
Amendment 0017.pdf PDF
Amendment 0016.pdf PDF
Amendment 0016 Revised Drawings.pdf PDF
Amendment 0016 Revised Specifications.pdf PDF
Amendment 0015.pdf PDF
Amendment 0014.pdf PDF
P702 JA Interior Finishes_redacted.pdf PDF
CU502_revised.pdf PDF
CM102_revised.pdf PDF
Amendment 0013.pdf PDF
Amendment 0012.pdf PDF
08 11 13_revised.pdf PDF
Amendment 0011.pdf PDF
Amendment 0010.pdf PDF
07 42 13 METAL WALL PANELS - Amendment 0010.pdf PDF
Arch Sheet - Amendment 0010.pdf PDF
41 22 13 15_Rev1.pdf PDF
13 34 19_Rev1.pdf PDF
P702 Structural Drawings.pdf PDF
Attachment E - Price Proposal Form Seed Project revised.docx DOCX document
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Final FFE Package.pdf PDF
CIVIL SHEETS 007.pdf PDF
MECH SHEETS 0007.pdf PDF
P702-1704807-ELEC DWGS.pdf PDF
P702-1704807-CIVIL DWGS.pdf PDF
P702-Geotechnical Data Report.pdf PDF
VNG Natural Gas Line Agreement.pdf PDF
Gate 6 Site Characterization Report.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
23R2562 P702 Site Visit Log.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment H - P702 Drawings.pdf PDF
P702 Specifications Amendment Section 01 50 00.pdf PDF
Attachment I - Approved Identity Proofing Documents.pdf PDF
N4008523R2562 SB MACC HR GEN CONSTR.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment K - SECNAV 5512.pdf PDF
Attachment G - P702 Specifications.pdf PDF
Attachment E - Price Proposal Form Seed Project.docx DOCX document
Attachment J - Criteria for Denying Access to Navy Installations.pdf PDF
Attachment A - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

E

F

1 2 3 4 5 6 7

CF-1

C1

MI301

AC-1

ODU-3 ODU-4ODU-1ODU-2

1 1 1 1

B

TYP

B

B

B

B

B

2 TYP

B

B

B

B

B

B

B

B

B

B

"ø

S A

"ø

S A

"ø

S A

"ø

S A

CF-2

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

"ø

S A

"ø

S A

"ø

S A

"ø

S A

"ø

S A

"x

" R

A

DOAS-3

DOAS-4

2 TYP 2 TYP

AC-2

"x

" R

A

4 4 4 4

F

F 1240 F

F

C

D

DOAS-1

"ø

R A

"ø

R A

"ø

R A

"ø

R A

5 5 5 5

A1

MI301

101A

106B

100A

MI401

C1

DOAS-2

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/

/2

2:

:3

PM

C :\U se rs

\ra ym on d.

lim pi n\ D oc um en ts

\P

2-

7- M

_r ay m on d.

lim pi n.

rv t

MH101

P-

-S

UB

M

AR

IN

E

LO

G

IS

TI

CS

S

UP

PO

RT

F

AC

IL

IT

IE

S

FL

O

O R

PL

AN

DU

CT

W

O

RK

DGS

12873810

BPD DJM

09/08/2022

GEOFFREY MOSS, DIRECTOR OF

WARFARE REQUIREMENTS, VIA

EMAIL

WMS/GKC

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

EJA

ALG

DSN

M

ID

LA

N

T D

C C

O R

E

M H

SCALE: 1/8" = 1'-0"

FLOOR PLAN - DUCTWORK

ROOM NAMES

100 HALLWAY

100A VESTIBULE

101 STORAGE

101A TEL COM.

102 OFFICE

103 WOMENS RESTROOM

103 WOMENS SHOWER

104 OFFICE

105 MENS RESTROOM

105 MEN SHOWER

106 LOUNGE

106B JAN. CL.

107 MECHANICAL ROOM

108 ELECTRICAL ROOM

109 FIRE PROTECTION ROOM

1 SEE DETAIL A2, PAD ON SLAB, SHEET MI501.

2 SEE DETAIL A1, TYPICAL DRUM LOUVER DETAIL, SHEET MI502.

3 SEE DETAIL C1, AIR CURTAIN FAN, SHEET MI501.

4 RETURN AIR LOUVER, SEE ARCHITECTURAL SHEET AE602 FOR MORE DETAIL.

5 DOAS SERVICE CLEARANCE SHOWN AT 3' FROM EDGES OF UNIT.

6 SEE DETAIL C1, TYPICAL EXTERIOR EQUIPMENT PAD (END VIEW), SHEET CM-501.

GENERAL NOTES KEYNOTES

GRAPHIC SCALE(S)

PLAN

NORTH

1. FOR ALL DUCTWORK EXPOSED TO THE OUTDOORS, PROVIDE

PREFABRICATED DOUBLE-WALL DUCTWORK WITH STAINLESS STEEL OUTER

SHELL (20 GAUGE MINIMUM) AND SOLID GALVANIZED STEEL INNER LINER (IN

ACCORDANCE WITH SMACNA), CONFIGURED AND SEALED FOR WEATHER

PROTECTION. PROVIDE 2 INCHES OF INSULATION BETWEEN THE OUTER

SHELL AND INNER LINER.

2. FOR ALL DUCTWORK INSIDE ROOM 101, PROVIDE PREFABRICATED DOUBLE-

WALL DUCTWORK WITH GALVANIZED STEEL OUTER SHELL AND SOLID

GALVANIZED METAL INNER LINER, IN ACCORDANCE WITH SMACNA.

PROVIDE 2 INCHES OF INSULATION BETWEEN THE OUTER SHELL AND INNER

LINER. PAINT THE OUTER SHELL IN ACCORDANCE WITH THE FINISH

SCHEDULE. COORDINATE WITH THE CONTRACTING OFFICER TO

DETERMINE PAINT COLOR.

3. ALL DUCTWORK AND EQUIPMENT SHOWN IS DIAGRAMMATIC. LOCATE ALL

DUCTWORK AND EQUIPMENT SO AS TO CLEAR ALL OBSTACLES.

4. PERFORM ALL WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE,

AND LOCAL CODES.

5. COORDINATE ALL HVAC INSTALLATIONS WITH ALL APPLICABLE TRADES.

6. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF

INSTALLATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT. BRING

DISCREPANCIES IN THE FIELD WITH CONTRACT DRAWINGS TO THE

ATTENTION OF THE CONTRACTING OFFICER IMMEDIATELY FOR

RESOLUTION.

7. COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR

GOVERNMENT FURNISHED GOVERNMENT INSTALLED EQUIPMENT WITH

THE CONTRACTING OFFICER.

8. LOCATE MANUAL BALANCING DAMPERS 2.5 DUCT DAMPERS AWAY FROM

DIFFUSER OR GRILLE TO ENSURE ACCESSIBILITY FOR O&M PERSONNEL

WITHOUT DAMPER NOISE FOR OCCUPANTS.

1/8" = 1' - 0" 0 5' 10' 15' 30'

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

Am en dm en t 0

/14

/20

BP

D

100102

106B

A

B

E

F

1 2 3 4 5 6 7

IDU-1

ODU-2 ODU-3 ODU-4ODU-1

2 HP-3

HP-2

HP-1

MI401

A4

3TYP.

4TYP.

C

D

T

T

T

T T

RS/RL

101A

HF

DOAS-1

DOAS-3 DOAS-4

CONO2

DOAS-2

5 5 5 5

1 1 /2"

D

1 1 /2"

D

1 1 /2"

D

1 1 /2"

D

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/

/2

2:

:3

PM

C :\U se rs

\ra ym on d.

lim pi n\ D oc um en ts

\P

2-

7- M

_r ay m on d.

lim pi n.

rv t

MP101

P-

-S

UB

M

AR

IN

E

LO

G

IS

TI

CS

S

UP

PO

RT

F

AC

IL

IT

IE

S

FL

O

O R

PL

AN

M

EC

HA

NI

CA

L

PI

PI

NG

DGS

12873811

BPD DJM

09/08/2022

GEOFFREY MOSS, DIRECTOR OF

WARFARE REQUIREMENTS, VIA

EMAIL

WMS/GKC

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

EJA

ALG

DSN

M

ID

LA

N

T D

C C

O R

E

M P1

SCALE: 1/8" = 1'-0"

FLOOR PLAN - MECHANICAL PIPING

ROOM NAMES

100 HALLWAY

100A VESTIBULE

101 STORAGE

101A TEL COM.

102 OFFICE

103 WOMENS RESTROOM

103 WOMENS SHOWER

104 OFFICE

105 MENS RESTROOM

105 MEN SHOWER

106 LOUNGE

106B JAN. CL.

107 MECHANICAL ROOM

108 ELECTRICAL ROOM

109 FIRE PROTECTION ROOM

1 SEE DETAIL B2, WALL PENETRIATION, SHEET MI501.

2 MOUNT IDU TO WALL. RUN CONDENSATE LINE TO MECHANICAL ROOM AND

CONNECT TO HP-1 CONDENSATE LINE. SIZE THE COMBINED LINES ACCORDINLY.

SEE DETAILS C2, DUCTLESS AC, SHEET M-501, AND A3, CONDENSATE DRAIN

PIPING DIAGRAM, SHEET M-502.

3 SEE DETAIL B2, PIPE SUPPORT STAND, SHEET MI502.

4 RS/RL TO INDOOR UNITS. SIZE LINES IN ACCORDANCE WITH MANUFACTURES

INSTRUCTIONS.

5 CONNECT CONDENSATE LINE TO STORM SEWER 4" PVC PIPE. PROVIDE AIR GAP

BETWEEN CONNECTION AT DOAS UNIT AND STORM SEWER PIPE.

PLAN

NORTH

GENERAL NOTES KEYNOTES

GRAPHIC SCALE(S)

1/8" = 1' - 0" 0 5' 10' 15' 30'

1. FOR ALL DUCTWORK EXPOSED TO THE OUTDOORS, PROVIDE

PREFABRICATED DOUBLE-WALL DUCTWORK WITH STAINLESS STEEL OUTER

SHELL (20 GAUGE MINIMUM) AND SOLID GALVANIZED STEEL INNER LINER (IN

ACCORDANCE WITH SMACNA), CONFIGURED AND SEALED FOR WEATHER

PROTECTION. PROVIDE 2 INCHES OF INSULATION BETWEEN THE OUTER

SHELL AND INNER LINER.

2. FOR ALL DUCTWORK INSIDE ROOM 101, PROVIDE PREFABRICATED DOUBLE-

WALL DUCTWORK WITH GALVANIZED STEEL OUTER SHELL AND SOLID

GALVANIZED METAL INNER LINER, IN ACCORDANCE WITH SMACNA.

PROVIDE 2 INCHES OF INSULATION BETWEEN THE OUTER SHELL AND INNER

LINER. PAINT THE OUTER SHELL IN ACCORDANCE WITH THE FINISH

SCHEDULE. COORDINATE WITH THE CONTRACTING OFFICER TO

DETERMINE PAINT COLOR.

3. ALL DUCTWORK AND EQUIPMENT SHOWN IS DIAGRAMMATIC. LOCATE ALL

DUCTWORK AND EQUIPMENT SO AS TO CLEAR ALL OBSTACLES.

4. PERFORM ALL WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE,

AND LOCAL CODES.

5. COORDINATE ALL HVAC INSTALLATIONS WITH ALL APPLICABLE TRADES.

6. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF

INSTALLATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT. BRING

DISCREPANCIES IN THE FIELD WITH CONTRACT DRAWINGS TO THE

ATTENTION OF THE CONTRACTING OFFICER IMMEDIATELY FOR

RESOLUTION.

7. COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR

GOVERNMENT FURNISHED GOVERNMENT INSTALLED EQUIPMENT WITH

THE CONTRACTING OFFICER.

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

Am en dm en t 0

/14

/20

BP

D

1 1 1 1

E

HP-3

HP-2

HP-1

FD-3

107RS/RL

RS/RL

101A

106B

IDU-1

RS/RL

RS/RL

2" D

1 1/4" D

1 1/4" D

E

F

2 3 4 5 6

IDU-1

A

K

A

L

M

I

M

C

C

M 400

TYP

CH-1

CH-2

A

A

HP-1

HP-2

HP-3

UH-1

A

G

UH-3

UH-2

A

C

C 50H

H

C 110C 125G 125

101A

106B

J

G

G

C 125

C

9 9

DDC CONTROL PANEL

"x

" R

A

"x

" R

A

12"ø SA12"ø SA

10"x12" RA

10"ø SA

16"x12" RA

10"ø SA

12"x12" RA

7 5

E

E

D

D

8"ø SA

"ø

S A

"x

" R

A

8" ø

SA

100A

12"x10" RA

10"x10" RA

10"x10" RA

10"x10" RA

10"x10" RA

12"x10" RA

6"ø SA

10"ø SA

12"x10" RA

10"ø SA

8"ø SA

10"ø SA

10"x10" RA

10"x10" RA

8" ø

SA

6"ø SA

8"ø SA

10"x6" RA

10"x6" RA

8"ø SA

8"ø SA

4" ø

12"x12" RA

12"x12" RA

6" ø

SA

10"ø SA 6" ø

SA

8"ø SA

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/

/2

2:

:3

PM

C :\U se rs

\ra ym on d.

lim pi n\ D oc um en ts

\P

2-

7- M

_r ay m on d.

lim pi n.

rv t

MI401

P-

-S

UB

M

AR

IN

E

LO

G

IS

TI

CS

S

UP

PO

RT

F

AC

IL

IT

IE

S

EN

LA

RG

ED

F

LO

O R

PL

AN

S

DGS

12873813

BPD DJM

09/08/2022

GEOFFREY MOSS, DIRECTOR OF

WARFARE REQUIREMENTS, VIA

EMAIL

WMS/GKC

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

EJA

ALG

DSN

M

ID

LA

N

T D

C C

O R

E

M I4

GENERAL NOTES KEYNOTES

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (MP101)A4 ENLARGED FLOOR PLAN - MECHANICAL ROOM - PIPING

1 CONTRACTOR TO SUPPLY FIELD INSTALLED FRAME TO MOUNT UNIT TO THE FLOOR.

2 SEE DETAIL C4, TYPICAL DUCT BRANCH DETAIL, SHEET MI501.

3 SEE DETAIL A4, TYPICAL SUPPLY DIFFUSER INSTALLATION DETAIL, SHEET MI501.

4 SEE DETAIL B1, DUCT PENETRATION DETAIL, SHEET MI501.

5 WALL CAP WITH BIRD SCREEN AND BACKDRAFT DAMPER.

6 SEE DETAIL A1, ELECTRIC UNIT HEATER, SHEET MI501.

7 PROVIDE CLOTHES DRYER EXHAUST DUCT PENETRATION THROUGH EXTERIOR WALL AT HEIGHT OF CLOTHES DRYER EXHAUST DUCT OUTLET TO ENABLE MINIMUM

DUCT LENGTH WITHOUT TURNS IN THE DUCT.

8 SEE DETAIL B1, TRANSFER DUCT ELEVATION VIEW, SHEET MI502.

9 LOCATE THE EDGE OF THE FACE OF THE DIFFUSER OR GRILLE 4” FROM THE ADJACENT WALLS.

10 LOCATE THE EDGE OF THE FACE OF THE DIFFUSER OR GRILLE 18” FROM THE CLOSEST WALL; LOCATE THE CENTER OF THE DIFFUSER OR GRILLE HALF THE DISTANCE

BETWEEN WALLS ADJACENT TO THE CLOSEST WALL.

11 LOCATE THE EDGE OF THE FACE OF THE GRILLE 4” FROM THE EDGE OF THE SHOWER; LOCATE THE CENTER OF THE GRILLE ON THE CENTERLINE OF THE SHOWER.

12 LOCATE THE EDGE OF THE FACE OF THE DIFFUSER OR GRILLE 24” FROM THE CLOSEST WALL; LOCATE THE CENTER OF THE DIFFUSER OR GRILLE HALF THE DISTANCE

BETWEEN WALLS ADJACENT TO THE CLOSEST WALL.

1. ALL DUCTWORK AND EQIUPMENT SHOWN ON THIS DRAWING IS

DIAGRAMMATIC. LOCATE ALL DUCTWORK AND EQUIPMENT SO AS TO CLEAR

ALL OBSTACLES.

2. PERFORM ALL WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE,

AND LOCAL CODES.

3. COORDINATE ALL HVAC INSTALLATIONS WITH ALL APPLICABLE TRADES.

4. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE START OF

INSTALLATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT. BRING ALL

CONSTRUCTION DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE

CONTRACTING OFFICER FOR A RESOLUTION.

5. COORDINATE ALL REQUIRED CONDUIT, PIPING AND CHASES FOR

GOVERNMENT FURNISHED GOVERMENT INSTALLED EQUIPMENT WITH THE

GOVERNMENT.

6. LOCATE MANUAL BALANCING DAMPERS 2.5 DUCT DAMPERS AWAY FROM

DIFFUSER OR GRILLE TO ENSURE ACCESSIBILITY FOR O&M PERSONNEL

WITHOUT DAMPER NOISE FOR OCCUPANTS.

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

Am en dm en t 0

/14

/20

BP

D

SCALE: 1/4" = 1'-0"C1 ENLARGED FLOOR PLAN - DUCTWORK

1/4" = 1' - 0" 0 5' 10' 15'1'

(MH101)

AMENDMENT 0005 MECHANICAL
MH101 - FLOOR PLAN - DUCTWORK
MP101 - FLOOR PLAN - MECHANICAL PIPING
MI401 - ENLARGED FLOOR PLANS

File details come from the government source that posted it. Updated .