View the file

Other files

File Type Posted
Amendment 0018.pdf PDF
Amendment 0017.pdf PDF
Amendment 0016.pdf PDF
Amendment 0016 Revised Drawings.pdf PDF
Amendment 0016 Revised Specifications.pdf PDF
Amendment 0015.pdf PDF
Amendment 0014.pdf PDF
P702 JA Interior Finishes_redacted.pdf PDF
CU502_revised.pdf PDF
CM102_revised.pdf PDF
Amendment 0013.pdf PDF
Amendment 0012.pdf PDF
08 11 13_revised.pdf PDF
Amendment 0011.pdf PDF
Amendment 0010.pdf PDF
07 42 13 METAL WALL PANELS - Amendment 0010.pdf PDF
Arch Sheet - Amendment 0010.pdf PDF
41 22 13 15_Rev1.pdf PDF
13 34 19_Rev1.pdf PDF
P702 Structural Drawings.pdf PDF
Attachment E - Price Proposal Form Seed Project revised.docx DOCX document
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Final FFE Package.pdf PDF
CIVIL SHEETS 007.pdf PDF
P702-1704807-ELEC DWGS.pdf PDF
P702-1704807-CIVIL DWGS.pdf PDF
P702-Geotechnical Data Report.pdf PDF
VNG Natural Gas Line Agreement.pdf PDF
Gate 6 Site Characterization Report.pdf PDF
Amendment 0006.pdf PDF
P702-1704807 MECH DWG.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
23R2562 P702 Site Visit Log.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment H - P702 Drawings.pdf PDF
P702 Specifications Amendment Section 01 50 00.pdf PDF
Attachment I - Approved Identity Proofing Documents.pdf PDF
N4008523R2562 SB MACC HR GEN CONSTR.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment K - SECNAV 5512.pdf PDF
Attachment G - P702 Specifications.pdf PDF
Attachment E - Price Proposal Form Seed Project.docx DOCX document
Attachment J - Criteria for Denying Access to Navy Installations.pdf PDF
Attachment A - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FACTORY PRE-

WIRED CONTROL

PANEL WITH

REMOTE ON-OFF

SWITCH ON WALL

NEAR DOOR

INTAKE LOUVERS

MIN. 14 GA. STEEL CABINET

AIR DIRECTION

CONTROL VANES

ROLL UP DOOR

PROVIDE

MANUFACTURERS

MOUNT FOR ATTACHING

AIR CURTAIN FAN. SEE

STRUCTURAL

DRAWINGS FOR MORE

DETAIL.

SECURE UNIT HEATER TO

WALL WITH A MINIMUM

OF TWO BRACKETS IN

ACCORDANCE WITH

MANUFACTURER'S

RECOMMENDATIONS

UNIT HEATER

TWO 5/8"∅ BOLTS, EACH

SIDE OF FRAME WITH

LOCK WASHERS

5/8"∅ EXPANSION

BOLTS TYP. FOR SIX

DUCT

20 GAGE GALVANIZED

STEEL COLLAR (EXPOSED

ONLY). SECURE TO WALL

ON 6 INCH CENTERS

(MINIMUM 4 FASTENERS

PER SIDE).

CMU WALL

GROUT

20 GAGE GALVANIZED

STEEL SLEEVE

OR RIVETED TO SLEEVE

INSULATION

1" CLEARANCE BETWEEN

2"x2"x1/4" TACKWELDED

6"

3"min

COORDINATE WITH

TRAP HEIGHT

WHERE

APPLICABLE

MECHANICAL EQUIPMENT

#4 REBAR, DRILLED & EPOXIED INTO

SLAB, EMBED MIN. 4", PLACE WITHIN 8"

OF SLAB PERIMETER @ MAX 4'-0" O.C.

6x6, W2.9xW2.9

WELDED WIRE FABRIC

@ MIDPOINT OF SLAB

TIE WELDED WIRE

FABRIC TO EACH DOWEL

CHAMFER EDGE 1"

@ 45°, ALL SIDES

45° 4"

45° 4"

45° 4"

BALANCING

DAMPER

BALANCING

DAMPER

BRANCH

MAIN DUCT

BALANCING

DAMPER

BALANCING

DAMPER

MAIN DUCT

BRANCH

MAIN DUCT

BRANCH

INSULATION SHIELD

1/21"ø STAINLESS

STEEL BOLT.

INSULATION WITH HIGH

DENSITY INSERT AT

SUPPORT

OFFSET PIPE CLAMP,

GALVANIZED, SIZE

CLAMP TO SUIT

INSULATION.

AIRFLOW

AIRFLOW

SA

INDOOR UNIT

WALL MOUNTING BRACKET

FURNISHED BY FCU MFGR.

WALL SLEEVE WITH CAPS

FURNISHED BY IDU MFGR.

DRAIN LINE TO FLOOR

DRAIN SEE DETAIL

CONDENSATE DRAIN

PIPING FOR SIZE.

THERMISTOR CABLE

CONNECTION CABLE

TO THERMOSTATREFRIGERANT

LINES; SIZE PER

MANUFACTURERS

GUIDANCE

POWER & HIGH VOLTAGE

CONTROL TO INDOOR UNIT

OUTDOOR UNIT

SECURE TO CONCRETE PAD

CONCRETE PAD

TOP OF UNIT 8' AFF

EXTERIOR WALL

PIPE SLEEVE

FILL WITH NON-

SHRINK GROUT

MINIMUM 1/4" CLEARANCE ALL AROUND

SEALANT BACKING MATERIAL

SEAL WITH WATERPROOF SEALANT

PIPE

PROVIDE 2" CLEARANCE ALL AROUND

FOR SPRINKLER PIPE.

SURFACE MOUNT SUPPLY

DIFFUSER

LAY-IN

90° RIGID ELBOW SIZED TO

MATCH DIFFUSER NECK SIZE

BRANCH

HANG AIR TERMINAL

INDEPENDENTLY OF

CEILING GRID WITH

16 GAUGE WIRE

5'-0" MAX FLEX

DUCT

SEE DETAIL C4,

TYPICAL DUCT

BRANCH DETAIL,

ON SHEET M-501

FOR MORE

INFORMATION.

USE NYLON STRAPS AND SCREWS

FOR ATTACHMENT OF FLEX TO

DUCT

USE NYLON STRAPS AND SCREWS FOR

ATTACHMENT OF FLEX TO ELBOW; PROVIDE

METAL BAND SUPPORT AT ELBOW

ATTACHED TO

BUILDING STEEL

FLEX TIE

SADDLE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/

/2

:2 7:

A

M C

:\U se rs \ra ym on d.

lim pi n\

D oc um en ts \P

2-

7-

M

_r ay m on d.

lim pi n.

rv t

MI501

P-

-S

UB

M

AR

IN

E

LO

G

IS

TI

CS

S

UP

PO

RT

F

AC

IL

IT

IE

S

M

EC

HA

NI

CA

L

DE

TA

IL

S

DGS

12873814

DJM DJM

09/08/2022

GEOFFREY MOSS, DIRECTOR OF

WARFARE REQUIREMENTS, VIA

EMAIL

WMS/GKC

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

EJA

ALG

DSN

M

ID

LA

N

T D

C C

O R

E

M I5

SCALE: NOT TO SCALEC1 DETAIL - AIR CURTAIN FAN

SCALE: NOT TO SCALEA1 DETAIL - ELECTRIC UNIT HEATER

SCALE: NOT TO SCALEB1 DETAIL - DUCT PENETRATION

SCALE: NOT TO SCALEA2 DETAIL - PAD ON SLAB

SCALE: NOT TO SCALEC4 DETAIL - TYPICAL DUCT BRANCH DETAIL

SCALE: NOT TO SCALEB4 DETAIL - VERTICAL PIPE SUPPORT

SCALE: NOT TO SCALEC2 DETAIL - DUCTLESS AC - WALL

SCALE: NOT TO SCALEB2 DETAIL - WALL PIPE SLEEVE - EXTERIOR

SCALE: NOT TO SCALEA4 DETAIL - TYPICAL SUPPLY DIFFUSER INSTALLATION DETAIL

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

AM

EN

DM

EN

T

/20

/20

BP

D

Sheets
MI501 - MECHANICAL DETAILS

File details come from the government source that posted it. Updated .