FACTORY PRE-
WIRED CONTROL
PANEL WITH
REMOTE ON-OFF
SWITCH ON WALL
NEAR DOOR
INTAKE LOUVERS
MIN. 14 GA. STEEL CABINET
AIR DIRECTION
CONTROL VANES
ROLL UP DOOR
PROVIDE
MANUFACTURERS
MOUNT FOR ATTACHING
AIR CURTAIN FAN. SEE
STRUCTURAL
DRAWINGS FOR MORE
DETAIL.
SECURE UNIT HEATER TO
WALL WITH A MINIMUM
OF TWO BRACKETS IN
ACCORDANCE WITH
MANUFACTURER'S
RECOMMENDATIONS
UNIT HEATER
TWO 5/8"∅ BOLTS, EACH
SIDE OF FRAME WITH
LOCK WASHERS
5/8"∅ EXPANSION
BOLTS TYP. FOR SIX
DUCT
20 GAGE GALVANIZED
STEEL COLLAR (EXPOSED
ONLY). SECURE TO WALL
ON 6 INCH CENTERS
(MINIMUM 4 FASTENERS
PER SIDE).
CMU WALL
GROUT
20 GAGE GALVANIZED
STEEL SLEEVE
OR RIVETED TO SLEEVE
INSULATION
1" CLEARANCE BETWEEN
2"x2"x1/4" TACKWELDED
6"
3"min
COORDINATE WITH
TRAP HEIGHT
WHERE
APPLICABLE
MECHANICAL EQUIPMENT
#4 REBAR, DRILLED & EPOXIED INTO
SLAB, EMBED MIN. 4", PLACE WITHIN 8"
OF SLAB PERIMETER @ MAX 4'-0" O.C.
6x6, W2.9xW2.9
WELDED WIRE FABRIC
@ MIDPOINT OF SLAB
TIE WELDED WIRE
FABRIC TO EACH DOWEL
CHAMFER EDGE 1"
@ 45°, ALL SIDES
45° 4"
45° 4"
45° 4"
BALANCING
DAMPER
BALANCING
DAMPER
BRANCH
MAIN DUCT
BALANCING
DAMPER
BALANCING
DAMPER
MAIN DUCT
BRANCH
MAIN DUCT
BRANCH
INSULATION SHIELD
1/21"ø STAINLESS
STEEL BOLT.
INSULATION WITH HIGH
DENSITY INSERT AT
SUPPORT
OFFSET PIPE CLAMP,
GALVANIZED, SIZE
CLAMP TO SUIT
INSULATION.
AIRFLOW
AIRFLOW
SA
INDOOR UNIT
WALL MOUNTING BRACKET
FURNISHED BY FCU MFGR.
WALL SLEEVE WITH CAPS
FURNISHED BY IDU MFGR.
DRAIN LINE TO FLOOR
DRAIN SEE DETAIL
CONDENSATE DRAIN
PIPING FOR SIZE.
THERMISTOR CABLE
CONNECTION CABLE
TO THERMOSTATREFRIGERANT
LINES; SIZE PER
MANUFACTURERS
GUIDANCE
POWER & HIGH VOLTAGE
CONTROL TO INDOOR UNIT
OUTDOOR UNIT
SECURE TO CONCRETE PAD
CONCRETE PAD
TOP OF UNIT 8' AFF
EXTERIOR WALL
PIPE SLEEVE
FILL WITH NON-
SHRINK GROUT
MINIMUM 1/4" CLEARANCE ALL AROUND
SEALANT BACKING MATERIAL
SEAL WITH WATERPROOF SEALANT
PIPE
PROVIDE 2" CLEARANCE ALL AROUND
FOR SPRINKLER PIPE.
SURFACE MOUNT SUPPLY
DIFFUSER
LAY-IN
90° RIGID ELBOW SIZED TO
MATCH DIFFUSER NECK SIZE
BRANCH
HANG AIR TERMINAL
INDEPENDENTLY OF
CEILING GRID WITH
16 GAUGE WIRE
5'-0" MAX FLEX
DUCT
SEE DETAIL C4,
TYPICAL DUCT
BRANCH DETAIL,
ON SHEET M-501
FOR MORE
INFORMATION.
USE NYLON STRAPS AND SCREWS
FOR ATTACHMENT OF FLEX TO
DUCT
USE NYLON STRAPS AND SCREWS FOR
ATTACHMENT OF FLEX TO ELBOW; PROVIDE
METAL BAND SUPPORT AT ELBOW
ATTACHED TO
BUILDING STEEL
FLEX TIE
SADDLE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/
/2
:2 7:
A
M C
:\U se rs \ra ym on d.
lim pi n\
D oc um en ts \P
2-
7-
M
_r ay m on d.
lim pi n.
rv t
MI501
P-
-S
UB
M
AR
IN
E
LO
G
IS
TI
CS
S
UP
PO
RT
F
AC
IL
IT
IE
S
M
EC
HA
NI
CA
L
DE
TA
IL
S
DGS
12873814
DJM DJM
09/08/2022
GEOFFREY MOSS, DIRECTOR OF
WARFARE REQUIREMENTS, VIA
WMS/GKC
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
EJA
ALG
DSN
M
ID
LA
N
T D
C C
O R
E
M I5
SCALE: NOT TO SCALEC1 DETAIL - AIR CURTAIN FAN
SCALE: NOT TO SCALEA1 DETAIL - ELECTRIC UNIT HEATER
SCALE: NOT TO SCALEB1 DETAIL - DUCT PENETRATION
SCALE: NOT TO SCALEA2 DETAIL - PAD ON SLAB
SCALE: NOT TO SCALEC4 DETAIL - TYPICAL DUCT BRANCH DETAIL
SCALE: NOT TO SCALEB4 DETAIL - VERTICAL PIPE SUPPORT
SCALE: NOT TO SCALEC2 DETAIL - DUCTLESS AC - WALL
SCALE: NOT TO SCALEB2 DETAIL - WALL PIPE SLEEVE - EXTERIOR