Cat A Items
| CATEGORY “A” ITEMS | |||||||||||||
| GENERAL REQUIREMENT | PRIME Contractor | SUB Contractor | Govt Mandated Tech Rep / Sub | OTHER COSTS | TOTAL PRICE | ||||||||
| ITEM NO. | TITLE CAT A ITEM | PRIME L/H | LABOR PRICE | MATERIAL PRICE | SUB L/H | LABOR PRICE | MATERIAL PRICE | Price | TOTAL LABOR HOURS | TOTAL MATERIAL | CLIN | ||
| CATEGORY "A" | |||||||||||||
| 000 | GENERAL REQUIREMENTS | ||||||||||||
| 001 | Intent, Scope, General Requirements, and Definitions | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 002 | Technical and Manufacturer’s Representatives | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 003 | Approach, Berth, and Mooring Requirements | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 004 | Testing and Quality Assurance | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 005 | Electrical Safety Procedure Requirements | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 006 | Heavy Weather Plan | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 007 | Cold Weather Plan | - 0 | $ - 0 | NSP | 0001 | ||||||||
| 10 | Furnish Office for Overhaul Management Team (OMT) | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 11 | General Services for the Ship | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 12 | Telephone Services | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 13 | Project Planning; Production Status Monitoring Reports; Test Planning and Lessons Learned | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 14 | Preparation of Weight and Moment Report | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 15 | Integrated Logistics and GFM Support Requirements | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 16 | Fire Protection and Ship's Safety Program | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 17 | Handling Ships Stores | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 18 | Delivery and Redelivery | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 19 | Shipboard Access and Security | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 20 | Gas Free Certificates | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 21 | Clean and Gas Free Tanks, Voids, Cofferdams & Spaces | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 22 | Dock Trials and Sea Trials | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 23 | Hazardous Waste Disposal at a Contractor's Facility | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 100 | HULL STRUCTURES | ||||||||||||
| 101 | Tank Inspections (ABS/ USCG) | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 102 | AFT Cable Deck Scuttle Replacement | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 103 | FWD & AFT Climber Ladder and Climber Safety Rail Repair | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 104 | Hatch 2-16-1 Deck Plate and Coaming Renewal | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 105 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 106 | Cone Landing and Grating Replacement | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 107 | Repair and Preserve SSDG Intake Plenums | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 108 | Stack Rail Renewal | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 109 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 110 | Joiner Door Replace | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 111 | Steel Repairs | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 112 | Aircraft Tiedown Testing and Renewal | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 113 | Evap Foundation Renewal | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 114 | Hull Plate Gauging | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 200 | MAIN PROPULSION | ||||||||||||
| 201 | SSDG Overhaul Assistance | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 202 | Automation System Repairs & Grooms | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 203 | Repair Exhaust Leaks in STBD Stack | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 204 | Replace STBD Main Motor LO Sump Heater | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 205 | Inspect Propulsion Motors | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 300 | ELECTRICAL | ||||||||||||
| 301 | Remove, Transport, Reinstall and Load Test NO. 1,2,3,4, &5 SSDG Generators | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 302 | Rewind SSDG NO. 1,2,3,4 &5 Generators, Rotors, and Stators | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 303 | Repair and Groom 44 MC | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 304 | Remove and Overhaul Cable Drum Motors | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 306 | Remove Dead Ended Cables MCC and MMR 1 | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 307 | Switchboard Shipyard Support | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 308 | SSDG Local Control Cabinet Support | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 400 | COMMUNIC ATION & NAV AIDS | ||||||||||||
| 401 | Reserved | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 402 | Replace ECHO Sounder and Digital Display | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 403 | Replace Speedlog | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 404 | SSAS Upgrade | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 405 | Time Standard Replacement | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 406 | Groom Ships Navigational SUITE | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 407 | External Communications SUITE System Maintenance | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 408 | SVDR GMDSS Annual Recertification | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 409 | Antenna Survey and Photographs | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 411 | Gyro Compass and Steering Servicing | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 412 | Magnetic Compass Calibration | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 413 | Service and Groom Dial Telephone System | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 500 | AUXILIARY MACHINERY | ||||||||||||
| 501 | Ballast Valve Actuator Repairs | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 502 | Reserved | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 503 | FWD Cable Deck Door Winch and Motor Repair | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 504 | Replace Shill Water Valves | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 505 | Replace Drain Piping | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 506 | Replace Yale 2 - Ton Trolley Hoist | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 507 | Repair A/C SW System | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 508 | LO Flex Hose Replacement | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 509 | Repair VCHT System | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 510 | Repair and Commision MSD Unit | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 511 | Evacuate and Repair A/C Freon Piping | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 512 | Evacuate and Repair Reefer Piping | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 513 | HVAC Coil Repair | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 514 | Renew BT SW Controller Enclosure | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 515 | Boiler Feed Pumps | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 516 | SIM Pump Repairs | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 517 | FO Storage Tank Piping Repairs | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 518 | Number 1 LPAC Overhaul | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 519 | Pressure Vessel Inspection and Hydrostatic Testing (USCG) | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 520 | FW Control, Combustion Control, Burner Management Inspection | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 521 | Auxiliary Boiler Inspection and Lay Up | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 522 | Oily Water Separator Repair and Annual Testing | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 523 | Fire Detect System; USCG Annual Inspection | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 524 | Halon and CO2 Extinguishing System, USCG Annual Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 525 | Portable Fire Extinguishers Test and Inspect | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 526 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 527 | Forward Crane Rocking, Slewing Bolt, and Weight Testing | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 528 | AFT Crane Rocking, Slewing Bolts, and Weight Testing | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 529 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 530 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 531 | Bilge and Ballast Priming System - Pump and Motor Overhauls | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 532 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 533 | Isolate SW Cooling in AFT Main Space | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 534 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 535 | Boiler Salinity Panels Repair | ||||||||||||
| 536 | Install 16" SW Isolation Valve | ||||||||||||
| 537 | Replace Bow Thruster Cooler Drains and Vent Piping | ||||||||||||
| 538 | Overhaul ASW Pump and Motor | ||||||||||||
| 539 | Renew ASW Suction and Discharge Piping | ||||||||||||
| 600 | HABITABILITY | ||||||||||||
| 601 | Port and STBD Buoy Recovery Sheaves | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 602 | Replace Galley Disposals | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 603 | Hydroblast Deck Drains | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 604 | Renew Grease Traps | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 605 | Install Door Release Magnets on Galley Fire Screen Doors | - 0 | $ - 0 | $0 | 0014 | ||||||||
| 606 | Bridge Window Replacements | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 607 | Overhaul NO. 1 Life Boat Engine Head and Test Hydraulic Start Accumulators | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 608 | Hydrostatic Testing of Fire Hoses | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 609 | Inflatable Liferafts, Annual Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 610 | Lifeboat Davit Annual Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 611 | SCBA Annual Inspection and Repair | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 612 | Cargo Elevator Inspection and Certification | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 613 | Survey and Repair Lathe in FWD Machine Shop | ||||||||||||
| 614 | Survey and Repair Lathe in AFT Machine Shop | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 700 | Mission Equipment | ||||||||||||
| 701 | Reserved | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 702 | Crane Lifts and JLG Support | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 703 | CCTV System Upgrade | ||||||||||||
| 704 | AFT Port Cable Drum Preservation | ||||||||||||
| 705 | BATHY Room MODS | ||||||||||||
| 706 | Transducer Removals | ||||||||||||
| 800 | Heating, Ventilation and Air Conditioning | ||||||||||||
| 801 | Ventilation Ducting Assessments in Compartment 3-18-2 | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 900 | DryDocking | ||||||||||||
| 901 | Docking and Undocking | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 902 | Sea Chests and Strainer Plates | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 903 | Underwater Hull Preservation | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 904 | Anchors and Anchor Chain Inspections | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 905 | Rudder and Bilge Keel Examination | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 906 | Sea Valves Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 907 | Cathodic Protection System Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 908 | Propeller Polishing and Examination | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 909 | Transducer Dome Cleaning and Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 911 | Anchors and Anchor Chain Preservation | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 912 | Propulsion Shaft Bearing Replacement | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 913 | Propulsion Shaft Removal and Inspection | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 914 | Propulsion Shaft Sleeve Replacement | - 0 | $ - 0 | $0 | 0001 | ||||||||
| 915 | Rudder Repairs | - 0 | $ - 0 | $0 | 0001 | ||||||||
| CLIN TOTALS | |||||||||||||
| 0001 | $0 | ||||||||||||
| 0002 | $0 | ||||||||||||
| 0003 | $0 | ||||||||||||
| 0004 | $0 | ||||||||||||
| 0005 | $0 | ||||||||||||
| 0006 | $0 | ||||||||||||
| 0007 | $0 | ||||||||||||
| 0008 | $0 | ||||||||||||
| 0009 | $0 | ||||||||||||
| 0010 | $0 | ||||||||||||
| 0011 | $0 | ||||||||||||
| 0012 | $0 | ||||||||||||
| 0013 | $0 | ||||||||||||
| 0014 | $0 | ||||||||||||
| 0015 | $0 | ||||||||||||
| 0016 | $0 | ||||||||||||
| 0017 | $0 | ||||||||||||
| 0018 | $0 | ||||||||||||
| 0019 | $0 | ||||||||||||
| 0020 | $0 |
&LUSNS ZEUS ROHDD&CCONTRACTOR PRICE BREAKDOWN
&"Arial,Bold"CATEGORY "A" ITEMS&RN00033-13-R-7505
&CATTACHMENT J-2
Cat B Items
| Contractor's price will be broken down for each item of the specification, as follows: | |||||||||||||||||
| CATEGORY “B” ITEMS | |||||||||||||||||
| GENERAL REQUIREMENT | Price / Tank | QTY | UI | Unit Price | Total | PRIME Contractor | SUBCONTRACTOR | OTHER COSTS | |||||||||
| ITEM NO. | TITLE CAT B ITEM | PRIME L/H | LABOR PRICE | MATERIAL PRICE | SUB L/H | LABOR PRICE | MATERIAL PRICE | Total Labor Hours | Total Material | TOTAL PRICE | CLIN | ||||||
| CATEGORY "B" | |||||||||||||||||
| 000 | GENERAL REQUIREMENTS | ||||||||||||||||
| 30 | Continuation of Services | - 0 | $ - 0 | $0 | 0003 | ||||||||||||
| 600 | OUTFIT, FURNISHING & HABITABILITY | ||||||||||||||||
| 612 | Survey and Repair Lathe in FWD Machine Shop | - 0 | $ - 0 | $0 | 0008 | ||||||||||||
| 900 | DRYDOCKING AND UNDOCKING | ||||||||||||||||
| 910 | Dry Dock Extension | - 0 | $ - 0 | $0 | 0009 | ||||||||||||
| 916 | Rudder Stock Sleeve Replacement | - 0 | $ - 0 | $0 | 0010 |