LRMC Attachment 9_Asbestos Locations.pdf
PDF 206 KB Posted
- Solicitation number
- HT9406-26-R-E006
- Issued by
-
Defense Health Agency
About this file
This document is an Asbestos Containing Material (ACM) Locations and Quantity inventory for Healthcare Environmental Cleaning (HEC) at Landstuhl Regional Medical Center and its outlying buildings. The inventory identifies the presence, status, and locations of asbestos-containing materials across multiple buildings and facilities.
The survey covers 13 primary buildings (3701, 3704, 3705, 3711, 3724, 3725, 3726, 3738, 3757, 3758, 3759, 3761, 3762, 3763, 3764, 3766, 3768, 3769, 3770, 3772, 3773, 3774, 3775, and 3810) with materials categorized as ACM (asbestos-containing material that has been confirmed and removed), PACM (presumed asbestos-containing material requiring long-term re-evaluation within five years), or ACM confirmed (still present and requiring re-evaluation). Materials identified include window sills, pipe flange gaskets, fire doors, floor tiles and mastic, insulation, wood wool tiles, brake pads, and shingles. Most ACM entries show quantities marked as N/A. The document notes that according to German requirements, many materials are assessed at Urgency Level III, requiring re-evaluation within a maximum five-year period. The inventory is signed by Facilities Management Supervisor Richard D. James on May 29, 2026, certifying the accuracy and completeness of the asbestos materials listing.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building # Department/Activity Floor # Room Use Asbestos Containing Material (ACM) Quantity Remarks
3701 Administrative Basement (BO) Heating Room ACM removed
N/A
No access to the room.
According to site personnel the entire building has been renovated. Previously UL II material expected to be removed.
3701 Administrative Basement (BO) Heating Room PACM removed
N/A
According to site personnel the entire building has been renovated. All inspected fire doors have been renewed.
3701 Administrative Third Floor (F3) Office,Hallway ACM removed
N/A
According to site personnel the entire building has been renovated.
The floors have been renewed. It is assumed that the green floor tiles and mastic were removed as part of the renovation work.
3701 Administrative Third Floor (F3) Office,Hallway ACM removed
N/A
According to site personnel the entire building has been renovated.
The floors have been renewed. It is assumed that the green floor tiles and mastic were removed as part of the renovation work.
3701 Administrative Third Floor (F3)
Office,Hallway
ACM removed
N/A
According to site personnel the entire building has been renovated. The floors have been renewed. It is assumed that the green and black floor tiles and mastic were removed as part of the renovation work.
3701 Administrative Third Floor (F3)
Office,Hallway
ACM removed
N/A
According to site personnel the entire building has been renovated.
The floors have been renewed. It is assumed that the green and black floor tiles and mastic were removed as part of the renovation work.
3701 Administrative Third Floor (F3) Office,Hallway PACM removed
N/A
According to site personnel the entire building has been renovated. No cargo lift was found during the inspection. It is assumed that it was removed during the renovation work.
3701 Administrative Third Floor (F3)
Office,Hallway
PACM removed
N/A
According to site personnel the entire building has been renovated. All inspected fire doors have been renewed.
3704 Administrative First Floor (Fl) Office PACM confirmed
N/A
Material inspected through the window.
Window sill considered as presumed asbestos containing material (PACM), requiring long-term re-evaluation {within maximum five years).
3705 Administrative First Floor (Fl) Heating Room PACM confirmed
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level Ill, requiring long-term re-evaluation {within maximum five years).
3705 Administrative First Floor (Fl) Office PACM assumed
N/A
The materials could not be verified during the inspection since not all rooms were accessible, and the room setup (numbering) had been changed.
The materials are considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation {within
3705 Administrative First Floor (Fl) Office PACM assumed
N/A
The material could not be verified during the inspection since not all rooms were accessible, and the room setup (numbering) had been changed.
The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation {within
3705 Administrative First Floor (Fl) Stairwell PACM confirmed
N/A
According to German requirements, intact fire doors are generally assessed as Urgency Level 111, requiring long-term re-evaluation {within maximum five years).
Asbestos Containing Material (ACM) Locations and Quantity
Healthcare Environmental Cleaning (HEC) for Landstuhl Regional Medical Center and its Outlying Buildings
3711 Medical Center Basement (BO) Utility Room PACM confirmed
N/A
Partly removed (renovated on 2018 & 2020)
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as
Urgency Level Ill, requiring long-term re-evaluation
{within maximum five years).
3711 Medical Center Basement (BO) Utility Room PACM confirmed
N/A
The elevator may contain asbestos-containing materials
(e.g. brake pads).
The material is considered as PACM, requiring long-term re-evaluation (within maximum five years).
3711 Medical Center First Floor (Fl) Hallway ACM removed
N/A
According to site personnel the floors have been renovated.
It is assumed that the floor tiles have been removed in the process of renovation work.
3711 Medical Center First Floor (Fl) Hallway ACM assumed
N/A
Restricted access to the facility.
The presence of window sills could not be verified during the inspection. It is assumed that the window sills are still present.
3711 Medical Center First Floor (Fl) Exterior ACM assumed
N/A
Restricted access to the facility.
The presence of shingles could not be verified during the inspection. It is assumed that the shingles are still present
3724 Administrative First Floor (Fl) Heating Room PACM confirmed
N/A
According to German requirements, intact fire doors are generally assessed as Urgency Level 111, requiring long-term re-evaluation {within maximum five years).
3724 Administrative First floor (Fl)
Heating Room
No asbestos detected
N/A
Inorganic fibers detected.
3724 Administrative Roof (RF) Exterior ACM removed
N/A
Renovated
3725 Medical Center First Floor (Fl) Heating Room PACM confirmed
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level
111, requiring long-term re-evaluation (within maximum five years).
3725 Medical Center First Floor (Fl) Heating Room PACM confirmed
N/A
According to German requirements, intact fire doors are generally assessed as Urgency Level 111, requiring long-term re-evaluation {within maximum five years).
3725 Medical Center First Floor (Fl) Office PACM confirmed
N/A
According to German requirements, brake pads in old elevators are generally assessed as Urgency Level 111, requiring long-term re-evaluation
(within maximum five years).
3726 Medical Center First floor (Fl) Heating Room PACM confirmed
N/A
Partly renovated.
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as
Urgency Level Ill, requiring long-term re-evaluation
{within maximum five years).
3726 Medical Center First Floor (Fl) Heating Room PACM removed
N/A
Removed and renovated
3738 Laboratory First Floor (Fl) Heating Room PACM removed
Renovated 2018, Moved to the attic
3757 Medical Center First Floor (Fl) Mechanical Room PACM confirmed
Still present. According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency level 111, requiring long-term re-evaluation (within maximum five years).
3757 Medical Center First Floor (Fl)
Mechanical Room
PACM confirmed
N/A
Window sills may contain asbestos. The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation (within maximum five years).
3757 Medical Center First Floor (Fl) Utility room PACM assumed
N/A
Brown floor tiles could not be verified during the resurvey inspection. The floor tiles might be still present below the PVC flooring.
Therefore, it is considered as PACM.
3758 Medical Center First Floor (Fl) Hallway PACM removed
N/A
Renovated
3758 Medical Center First Floor (Fl) Copy Rooom PACM assumed
N/A
N/A
3758 Medical Center First floor (Fl) Utility Room PACM assumed
N/A
N/A
3758 Medical Center First Floor (Fl) N/A PACM assumed
N/A
N/A
3758 Medical Center First Floor (Fl) Heating Room, Mechanical Room PACM
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level Ill, requiring long-term re-evaluation (within maximum five years).
3758 Medical Center First Floor (Fl)
Heating Room, Mechanical Room
AMF presumed
N/A
Distributed throughout the entire building.
3759 Medical Center First floor (Fl) Mechanical Room PACM confirmed
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level Ill, requiring long-term re-evaluation (within maximum five years).
3759 Medical Center First Floor (Fl) Mechanical Room PACM
N/A
Window sills in the mechanical room and the hallway adjacent to it. Window sills may contain asbestos. The material is considered as presumed asbestos containing material (PACM), requiring long-term re-evaluation (within maximum five years).
3759 Medical Center First Floor (Fl) Hallway, others AMF presumed
N/A
N/A
3761 Medical Center First Floor (Fl) Office PACM confirmed
N/A
Window sills may contain asbestos. The material is considered as presumed asbestos containing material (PACM), requiring long-term re-evaluation (within maximum five years).
3761 Medical Center First Floor (Fl)
Office
AMF presumed
3762 Medical Center First Floor (Fl) Mechanical room PACM confirmed
Partly renovated.
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as
Urgency level 111, requiring long-term re-evaluation
(within maximum five years).
3762 Medical Center First floor (Fl) N/A PACM assumed
N/A
Brown floor tiles 9" - 23 x 23 cm - and associated mastic on the first floor were identified as ACM in the
2009 survey. In the 2014 follow-up, it was noted that, although residents reported complete renovation, the presence of residual material beneath the current floor could not be excluded, and the product was therefore assessed as PACM. During the current survey, no visible residues were observed; however, due to limited access to subfloor layers, the previous PACM assessment remains valid as a precaution.
3762 Medical Center First Floor (Fl) N/A PACM assumed
N/A
Green floor tiles 9" - 23 x 23 cm and mastic in the first floor were identified as ACM in the 2009 survey. In the 2014 follow-up, it was noted that, although residents reported complete renovation, the presence of residual material beneath the current floor could not be excluded, and the product was therefore assessed as PACM. During the current survey, no visible residues were observed; however, due to limited access to subfloor layers, the previous PACM assessment remains valid as a precaution.
3763 Medical Center First Floor (Fl) Entire Section PACM confirmed
N/A
Window sills may contain asbestos. The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation (within maximum five years).
3763 Medical Center First Floor (Fl) Entire Section PACM assumed
N/A
White floor tiles 12" - 30 x 30 cm in building 3763A, Rooms 102, 108, 109, 109, 110, 111 in the first floor were identified as ACM in the 2009 survey. In the 2014 follow-up, it was noted that, although residents reported complete renovation, the presence of residual material beneath the current floor could not be excluded, and the product was therefore assessed as PACM. During the current survey, no visible residues were observed;
however, due to limited access to subfloor layers, the previous
PACM assessment remains valid as a precaution.
3764 Medical Center First Floor (Fl) Mechanical Room PACM confirmed
N/A
Window sills may contain asbestos. The material is considered as presumed asbestos containing material (PACM), requiring long-term re-evaluation (within maximum five years).
3764 Medical Center Second floor (F2) Mechanical Room PACM confirmed
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as
Urgency Level Ill, requiring long-term re-evaluation (within maximum five years).
3766 Medical Center First Floor (Fl) Storage ACM removed
N/A
N/A
3766 Medical Center First Floor (Fl) Storage ACM removed
N/A
N/A
3766 Medical Center First Floor (Fl) Storage PACM assumed
N/A
PACM could not be verified hence assumed to be still present
3768 Medical Center First Floor (Fl) Other ACM confirmed
Gray window sills contain chrysotile asbestos. The material is considered as asbestos containing material
(ACM), requiring long-term re-evaluation
(within maximum five years).
3768 Medical Center First Floor (Fl) Mechanical Room PACM
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level
111, requiring long-term re-evaluation (within maximum five years).
3769 Medical Center First Floor (Fl) Parts of the building PACM confirmed
N/A
Also present on the second floor.
Window sills may contain asbestos. The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation (within maximum five years).
3769 Medical Center Second Floor
(F2) Mechanical Room PACM confirmed
N/A
According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency Level
111, requiring long-term re-evaluation (within maximum five years).
3770 Medical Center First Floor (Fl) Hallway PACM confirmed
N/A
Still present . Window sills may contain asbestos. The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation (within maximum five years).
3772 Medical Center First Floor (Fl) Mechanical room PACM confirmed
N/A
Still present. According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency
Level Ill, requiring long-term re-evaluation (within maximum five years).
3772 Medical Center First Floor (Fl) Hallway,Office PACM confirmed
N/A
Still present . Window sills may contain asbestos. The material is considered as presumed asbestos containing material
(PACM), requiring long-term re-evaluation (within maximum five years).
3772 Medical Center First Floor (Fl)
Hallway,Office
PACM removed
N/A
N/A
3773 Chapel Basement (BO) Chapel PACM assumed
N/A
Previous survey identified 20 pipe flange gaskets in a crawl space at the basement. No access to basement during the 2014 survey, and during current survery however, it is assumed, that the gaskets are still present, therefore assessment as PACM.
3773 Chapel First Floor (Fl)
Chapel
ACM confirmed
N/A
Black floor covering is expected to be still present below the blue carpet.
Black floor covering contains chrysotile asbestos. The material is considered as asbestos containing material
(ACM), requiring long-term re-evaluation (within maximum five years).
3774 Medical Center First Floor (Fl) Mechanical room PACM confirmed
N/A
Renovated in one room and older in a smaller room
(Partly renewed). According to German requirements, pipe flange gaskets in technical equipment are generally assessed as Urgency level 111, requiring long-term re-evaluation (within maximum five years).
3775 Medical Center First Floor (Fl) N/A PACM assumed
N/A
Gray floor tiles 9" - 23 x 23 cm were ACM-identified in previous surveys on the first floor. The building has been renovated, and the floorings have been inspected randomly at several locations.
However, it cannot be excluded that residues of these
3775 Medical Center First Floor (Fl) N/A PACM assumed
N/A
3775 Medical Center First Floor (Fl) N/A PACM assumed
N/A
Beige floor tiles 12" - 30 x 30 cm were ACM-identified in previous surveys on the first floor. The building has been renovated, and the floorings have been inspected randomly at several locations. However, it cannot be excluded that residues of these floor tiles or mastic are still present in some parts below actual floor, therefore this product is assessed as PACM.
Insulation material (foam) was ACM-identified in previous surveys on the first floor. No further data is available. The building has been renovated, and material could not be verified. However, it cannot be
3775 Medical Center First Floor (Fl) N/A PACM assumed
In previous surveys, pipe flange gaskets were identified behind metal jackets in the utilities room and assessed as ACM. These gaskets could not be assessed due to no access to the heating rooms. However, it cannot be excluded that material is still present in some non-accessible areas.
3775 Medical Center First Floor (Fl) N/A ACM confirmed
N/A
Wood wool tiles contain chrysotile asbestos. The material is considered as asbestos containing material
(ACM), requiring medium-term re-evaluation
(within maximum two years).
3775 Medical Center First Floor (Fl) Attic ACM confirmed
N/A
Still present, Wood wool tiles contain chrysotile asbestos. The material is considered as asbestos containing material (ACM), requiring medium-term re-evaluation (within maximum two years).
3775 Medical Center First Floor (Fl)
Attic
PACM
N/A
According to German requirements, intact fire flaps are generally assessed as Urgency Level 111, requiring long-term re-evaluation (within a maximum of five years).
3810 Administrative First Floor (Fl) Office PACM assumed
N/A
Previous surveys identified ACM floor tiles in various areas. Although renovations were carried out and old tiles reportedly removed, residues could not be ruled out, and the areas were assessed as PACM. No visible
ACM tiles were found during the resurvey, but the presence of remnants
Facilities Management Supervisor Signature
I verify the information submitted in this exhibit, to the best of my knowledge, is an accurate and complete listing of locations containing asbestos materials.