SECTION J
DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
TABLE OF CONTENTS
ATTACHMENT
NUMBER
ATTACHMENT TITLE
| J-1606000-01 |
| Definitions and Acronyms |
| J-1606000-02 |
| References and Technical Documents |
| J-1606000-03 |
| Water Treatment and Distribution System Description |
| J-1606000-04 |
| Water Treatment and Distribution System Inventory |
| J-1606000-05 |
| Backflow Prevention Devices Inventory |
| J-1606000-06 |
| Water Meter Inventory |
ATTACHMENT J-1606000-01
DEFINITIONS AND ACRONYMS
| Definition/Acronym |
| Description |
| ANSI |
| American National Standards Institute |
| AWWA |
| American Water Works Association |
| DoD FGS |
| Department of Defense Environmental Final Governing Standards |
| DoD OEBGD |
| Overseas Environmental Baseline Guidance Document |
| FFHC |
| Fit For Human Consumption. Water that meets primary drinking water standards as defined by Final Governing Standards, Overseas Environmental Baseline Guidance Documents, and CNICINST 5090.1, and is safe for drinking, cooking, bathing, and other oral hygiene uses. |
| NFPA |
| National Fire Protection Association |
| NPDWR |
| National Primary Drinking Water Regulations |
| NSDWR |
| National Secondary Drinking Water Regulations |
| OMSI |
| Operation And Maintenance Support Information |
| UFC |
| Unified Facilities Criteria |
| USAPHC |
| United States Army Preventive Health Command |
| USEPA |
| US Environmental Protection Agency |
ATTACHMENT J-1606000-02
REFERENCES AND TECHNICAL DOCUMENTS
| Document No. |
| Document Title |
| UFC 3-440-02N |
| Water Conservation Operation and Maintenance |
| UFC 3-430-09 |
| Exterior Mechanical Utility Distribution |
| UFC 3-230-02 |
| Water Supply Systems |
| UFC 3-230-03 |
| Water Supply: Water Treatment |
| CNICINST 5090.1A |
| U.S. Drinking Water Quality Standards for Navy Installations |
| CNICINST 5090.2 |
| Overseas Drinking Water Operation and Operator Requirements |
| CNICINST 5090.3 |
| Navy Overseas Drinking Water Program Ashore |
| OPNAVINST 5090.1 |
| Environmental Readiness Program Manual |
| NAVMED P-5010-5 |
| Water Supply Ashore |
| UG-2029-ENV |
| Cross-Connection Control and Backflow Prevention Program Implementation at Navy Shore Facilities |
| AWWA M14 |
| Manual Cross Connection Control 9th Edition |
ATTACHMENT J-1606000-03
Raw Water, Water Treatment and Distribution Systems Description
Raw water system:
Two redundant well water pumps shall maintain the required amount of water in a water tank and in two fire tanks. Level transmitter shall provide level indication at each tank. A primary selector at the BAS shall allow the operator to select which pump shall start initially. Each well pump shall be supplied with motor starter and h-0-a switch. In the hand position the pump shall start and continue to run until manually stopped. With the switch in the auto position, the BAS shall start the primary well pump when the level in the water tank and/or either fire tank falls below the low level set point. The pump shall run until the level in all tanks reaches high liquid level. If the primary pump fails during operation, the stand by pump shall be energized to start and run. If the water level in either tank exceeds low-low or high-high level setpoint, an alarm shall be annunciated at the BAS. A normally closed motorized valve at the discharge of the well pumps shall provide isolation of the well pumps during shutdown. The valve shall open when the level in the potable water tank falls below low level set point. When the high level setpoint in the potable water tank is reached, the valve shall close. If after an adjustable time delay the valve is not proven open, an alarm shall be annunciated at the BAS. An independent float control valve, located at the inlet to the potable water tank shall stop flow to the tank, when the water reaches 0.25 m below the overflow level. If the well pump continues to run, a high-high pressure switch shall stop the pump. The pressure switch shall reset when the high level alarm resets to normal.
Potable water pressurization:
The pressure in the potable water system shall be maintained with two 50% tanks and two redundant pumps. The pumps shall be supplied in a skid, complete with h-0-a switch, indication lights and audible alarm, magnetic motor contactors, motor overload and lead/lag alternator. The pumps shall be alternated by the ddc at each startup to equalize runtime. The selected lead pump shall start when the pressure at either tank falls to 450 kpa and remain operational until the pressure in both tanks reaches 580 kpa. Each pump shall be provided with an integral controller that modulates the pump's speed to maintain differential pressure. This setpoint shall be manually set by the user at the pump. If running pump trouble is detected, the pump is disabled, an alarm is activated and the lag pump is enabled. If the lead pump is operational and cannot supply enough flow and the system pressure continues to fall, the lag pump shall start and run. Both pumps shall then run until the pressure in both tanks reaches 580 kpa setpoint. If the pressure at the operating pump suction falls below setpoint, a low pressure switch shall shut down the pump and indicate failure.
Pump trouble shall be detected either by general pump signal or system trouble at low and/or high high pressure. If during automatic operation the pump(s) fail to shut down, a high-high pressure switch shall activate an alarm at the BAS and stop the pump(s). A low-low pressure switch shall indicate failure of the pump(s) and activate an alarm at the BAS.
Sodium hypochlorite system:
The potable water shall be treated with sodium hypochlorite in two locations: before the tank to 5 ppm concentration and leaving the building to 2 ppm concentration. The sodium hypochlorite solution shall be stored in a tank and injected to each location with a dedicated metering pump on a fixed ratio. The ratio shall be adjustable and shall be provided by the BAS to the variable speed pump controller. Each pump shall be enabled by a signal from the BAS upon registering minimum water flow with flow meter. Each set point shall be manually set by the user at the pump. The sodium hypochlorite tank shall have a level transmitter to provide level indication at the BAS and permissive to the metering pumps.
Building and tanks heating system:
The building hot water system is designed to provide heating for the building and to protect the fire and potable water storage tanks from freezing. The system is primary, consisting of one electric hot water boiler, two pumps: lead and lag, and a piping loop, unit heaters and tank heaters. The boiler shall be provided with factory installed outdoor reset, leaving water temperature sensing, and capability to maintain temperature output by staging its electric elements.
Unit heaters shall maintain each room indoor temperature at setpoint of 7 deg c (adjustable). A dedicated room thermostat shall modulate the three way valves to all unit heater coils, located in that room. Immersion tank heaters shall maintain the stored water at setpoint of 5.6 deg c (adjustable). For each tank, a temperature transmitter on the return line shall open/close the associated three way valve to the associated heater.
The heating water system shall be controlled by the BAS. The system shall be enabled when either room temperature falls below setpoint and/or the outside air temperature falls to 2 deg c lower than the maximum active setpoint of 14 deg c (adjustable). The heating mode shall be disabled if all temperatures are 2 deg c above setpoint, and the outside air temperature rises above 2 deg c higher than the maximum active setpoint temperature of 14 deg c (adjustable) for a period of more than 5 min.
When the BAS places the system in the heating mode the lead pump shall start and run continuously. Whenever the cumulative run-time of the lead pump exceeds the cumulative run-time of the lag pump by 168 hours, the lead and lag pumps shall alternate function, with the lead becoming the lag pump, and the lag pump becoming the lead pump. During switchover, a time delay of 30 seconds shall be provided between stopping and starting of the pumps. An adjustable current switch shall prove system flow.
Once flow is proven, the BAS system shall start the boiler. When energized, the boiler shall operate under its factory installed internal safeties and controls to maintain the hot water supply temperature in accordance with a linear reset schedule. The boiler sequence controller shall simultaneously adjust capacity staging in order to achieve the heating water supply setpoint. If the boiler fails to start upon request and/or flow cannot be proved, the BAS system shall signal a boiler and/or pump failure alarm and time-stamp and store the event. Boiler temperature and pressure as indicated on the build-in temperature/pressure gauge shall not exceed normal operating limits (94 deg c and 205 kpa).
HWS reset schedule:
| OA temperature | -32 deg c 15 deg c |
| HWA temperature | 70 deg c 60 deg c |
ATTACHMENT J-1606000-04
Raw Water, Water Treatment and Distribution Systems Inventory
| Bldg |
| Location |
| Equipment Description |
| Equipment ID |
| Capacity |
| Qty |
| Remarks |
| Site |
| Raw Water Well |
| Submersible Pump |
| P-3019101 |
| Site |
| Raw Water Well |
| Submersible Pump |
| P-3019202 |
| 30 |
| Exterior |
| Storage Tank Potable Water |
| T-3012001 |
| 106,370 L |
| 1 |
| 30 |
| Mechanical Equipment Room |
| Storage Tank Potable Water |
| T-3012201 |
| 3000 L |
| 1 |
| Potable Water Hydropneumatic Tank |
| 30 |
| Mechanical Equipment Room |
| Storage Tank Potable Water |
| T-3012101 |
| 3000 L |
| 1 |
| Potable Water Hydropneumatic Tank |
| 30 |
| Exterior |
| Storage Tank – Fire System |
| T-3052001 |
| 397,360 L |
| 1 |
| 30 |
| Exterior |
| Storage Tank – Fire System |
| T-3052002 |
| 397,360 L |
| 1 |
| 30 |
| PW Storage Tank |
| Heat Exchanger |
| TWH-3022003 |
Storage Tank Heating - PW
| 30 |
| Fire Storage Tank |
| Heat Exchanger |
| TWH-3022001 |
Storage Tank Heating - Fire
| 30 |
| Fire Storage Tank |
| Heat Exchanger |
| TWH-3022002 |
Storage Tank Heating - fire
| 30 |
| Mechanical Equipment Room |
| Pressurization Pump |
| P-3012101 |
| 11 KW |
| 1 |
| Potable Water Booster Pump |
| 30 |
| Mechanical Equipment Room |
| Pressurization Pump |
| P-3012101 |
| 11 KW |
| 1 |
| Potable Water Booster Pump |
| 30 |
| Mechanical Equipment Room |
| Sodium Hypochlorite Tank |
| T-3007001 |
| 420 L |
| 1 |
| 30 |
| Mechanical Equipment Room |
| Water Treatment Metering Pump |
| P-3007101 |
| 0.14 KW |
| 1 |
| To Distribution Line |
| 30 |
| Mechanical Equipment Room |
| Water Treatment Metering Pump |
| P-3007201 |
| 0.14 KW |
| 1 |
| To Tank Inlet |
| 30 |
| Mechanical Equipment Room |
| Electric Hot Water Boiler |
| B-3022001 |
| 83 L |
| 1 |
| Water Storage Tank Heating, Bldg. 30 Space Heating |
| 30 |
| Mechanical Equipment Room |
| Heating Water Pump |
| P-3022101 |
| 2.2 KW |
| 1 |
| Water Storage Tank Heating, Bldg. 30 Space Heating |
| 30 |
| Mechanical Equipment Room |
| Heating Water Pump |
| P-3022201 |
| 2.2 KW |
| 1 |
| Water Storage Tank Heating, Bldg. 30 Space Heating |
| 30 |
| Mechanical Equipment Room |
| Expansion Tank |
| ET-3022001 |
| 30 L |
| 1 |
| Heating Water |
| 30 |
| Mechanical Equipment Room |
| Air Separator |
| AS-3022001 |
| 1 L |
| 1 |
| Heating Water |
| 30 |
| Mechanical Equipment Room |
| Automatic Backflush Strainer Unit |
| ST-3019001 |
ATTACHMENT J-1606000-05
Backflow Prevention Devices Inventory
| Bldg |
| Location |
| Equipment Description |
| Equipment ID |
| 30 |
| Mechanical Equipment Room |
| Backflow Preventer |
| BFP-3060001 |
| 30 |
| Mechanical Equipment Room |
| Backflow Preventer |
| BFP-3019001 |
ATTACHMENT J-1605000-06
WATER METER INVENTORY
Meter Location (Facility)
| Meter ID |
| Water System |
| Meter Type |
| 22 |
| WM-2212001 |
| Domestic Water Supply |
| Positive Displacement |
| 28 |
| WM-2812001 |
| Domestic Water Supply |
| Positive Displacement |
| 29 |
| WM-2912001 |
| Domestic Water Supply |
| Rotary |
| 30 |
| WM-3012001 |
| Domestic Water Supply |
| Positive Displacement |
| 43 |
| WM-4312001 |
| Domestic Water Supply |
| Electro-Magnetic |
| 44 |
| WM-4412001 |
| Domestic Water Supply |
| Rotary |
| 45 |
| WM-4512001 |
| Domestic Water Supply |
| Rotary |
| 46 |
| WM-4612001 |
| Domestic Water Supply |
| Positive Displacement |
TBD
TBD