I101D FLOOR FINISH PLAN -AREA D.pdf
PDF 204 KB Posted
- Attached to
- DLA Fitness Center Renovation Federal contract opportunity
- Solicitation number
- 1430
About this file
This floor finish plan and related federal contract opportunity provide details for renovating the fitness center at the Defense Supply Center Richmond in Virginia. The floor finish plan outlines the proposed flooring, wall, and ceiling materials for each area of the fitness center including 1985 square feet for aerobics, 401 square feet for martial arts, 1537 square feet for spinning, and storage and corridor space. The related solicitation seeks offers for the fitness center renovation project and was posted on April 13, 2020 with solicitation number 1430. The renovation is being conducted by the Department of the Army Corps of Engineers Norfolk District for the Defense Supply Center Richmond facility. Offerors should reference the floor finish plan for details on the proposed interior materials as they develop their responses to the solicitation.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1985 SF
AEROBICS
G105
401 SF
MARTIAL ARTS
G104
1537 SF
SPINNING
G102
632 SF
STORAGE
G106
375 SF
STORAGE
G103
1181 SF
CORRIDOR
G101
46 SF
VEST.
G100A
137 SF
RISER ROOM
G100B
AWP-1
A W
P -1
FLOOR FINISH LEGEND
ART-1
CPT-1
PC-1
SC-1
TRF-1
WDF-3
TS-6A
TS-6A
TS-3
TS-8
TS-3
TS-3
TS-6A
WS-1
V.I.F.
10' - 0"
V.I.F.
10' - 0"
WS-1
1 1
ACCENT WALL LEGEND
P-X ACCENT WALL PAINT LOCATION
WITH PAINT COLOR CODE. SEE
FINISH LEGEND FOR PAINT COLOR
INFORMATION.
A. REFERENCE ARCHITECTURAL FLOOR PLANS FOR FLOOR
RAMP TRANSITIONS. SEE KEYNOTE 128.
B. REFERENCE SHEET I-601 FOR INTERIOR FINISH LEGEND,
SCHEDULE AND DETAILS.
C. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS, &
REGISTERS IN DRYWALL CEILINGS AND WALLS TO ADJACENT
SURFACES.
D. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, OR LABELS.
E. FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF
DOOR, UNLESS NOTED OTHERWISE.
F. RESTROOM SHOWERS ARE PRECAST UNITS. SEE FINISH
LEGEND, I-601.
G. WINDOW SILLS TO BE SS-2.
H. BULLNOSE ALL EXPOSED EDGES AND OUTSIDE CORNERS OF
WALL TILE AND BASE.
I. INSIDE MOUNT WS-1 ON ALL INTERIOR WINDOWS. ALL
WINDOWS SHALL RECEIVE SHADES.
J. SLOPE TILED FLOORS TO FLOOR DRAINS AS REQUIRED.
FINISH PLAN GENERAL NOTES:
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
I101D
F L O
O R
F
IN
IS
H
P L A
N
A R
E A
D K
.B A
R K
E R
C .C
O L E
B .F
O R
E T
B .F
O R
E T
SCALE : 1/8" = 1'-0"A1 FLOOR FINISH PLAN - AREA D
4'0 8' 16'
GRAPHIC SCALE
PLAN NORTH
BAY GBAY F
KEY PLAN
D
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .