A-111A REFLECTED CEILING PLAN -AREA A.pdf
PDF 570 KB Posted
- Attached to
- DLA Fitness Center Renovation Federal contract opportunity
- Solicitation number
- 1430
About this file
This reflected ceiling plan drawing depicts the ceiling layout and design for renovations to the fitness center at the Defense Supply Center Richmond in Virginia. Key details include suspending 2' x 2' acoustic ceiling tiles across most of the facility, installing 4' x 8' cementitious wood fiber panels in specific areas, exposing the existing structure and painting all exposed surfaces and pipes in other areas, and adding large volume fans and access panels in select locations.
The related federal contract opportunity is a solicitation posted on April 13, 2020 by the Department of the Army Corps of Engineers Engineering District Norfolk seeking contractors to complete the fitness center renovation. Solicitation number 1430 describes the project as converting existing Bays F and G into a new fitness center at the Defense Supply Center Richmond location.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
SR
C
C
E T
ET
ET
E T
SS
C
SS
SS
REFLECTED CEILING LEGEND
EXIT LIGHT - CEILING
2' x 2' SUSPENDED
ACOUSTIC CEILING TILES
GYPSUM BOARD CEILING
2 X 4 LIGHT FIXTURE
SUSPENDED LIGHT FIXTURE
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
CEILING HEIGHT TAG
SD
S
SMOKE DETECTOR
SPEAKER
8'-0"
2' x 2' SUSPENDED
CEILING CLOUD W/MESH
STROBE
WOOD CEILING
4' X 8' CEMENTITIOUS
WOOD FIBER ACOUSTICAL
CEILING PANELS
1 X 4 LIGHT FIXTURE
RECESSED LIGHT FIXTURE
RECESSED DOWN LIGHT
CERAMIC TILE CEILING
CEILING FAN
4X8 T&G CEILING PANEL
A. CENTER CEILING GRID IN ROOM UNLESS SHOWN
OTHERWISE ON REFLECTED CEILING PLAN.
B. CENTER FIXTURES, MECHANICAL DIFFUSERS,
MECHANICAL GRILLES AND SPRINKLER HEADS IN
SUSPENDED ACOUSTICAL CEILING TILE SYSTEM
PANELS.
C. ALL CEILING MOUNTED ITEMS ARE SHOWN FOR
COORDINATION PURPOSES ONLY.
D. SEE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE
AND SPECIAL SYSTEM TYPES.
E. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND
GRILLE TYPES.
F. SEE FIRE PROTECTION FOR SPRINKLER TYPES.
SEE TELECOMMUNICATION AND FIRE PROTECTION
SYSTEMS FOR ADDITIONAL INFORMATION OF
CEILING MOUNTED DEVICES.
G. ALL RCP DIMENSIONS ARE CLEAR FINISHED
DIMENSIONS, UNLESS OTHERWISE NOTED.
H. REFER TO FINISH SCHEDULE FOR CEILING TYPES
AND HEIGHTS NOT INDICATED ON THE REFLECTED
CEILING PLANS.
I. ALL GYPSUM BOARD CEILING WITHIN 4'-0" OF
PERIMETER SHALL BE MOISTURE RESISTANT.
J. SMOKE AND HEAT DETECTORS TO BE GREATER
THAN 3'-0" FROM MECHANICAL DIFFUSERS.
RCP GENERAL NOTES:
1 2 3 4 5 6 7
A
B
C
D
E
F
G
EXISTING
MECHANICAL
F108
EXISTING
ELECTRICAL
F107
EXISTING RISER
ROOM
F103
RACQUETBALL
COURT
F114
PROGRAM DIR.
F104
BREAK
F106
STORAGE
F109
FUNCTIONAL
FITNESS
F113CIRCUIT
F112
CARDIO
F111
WEIGHT
F110
BREEZEWAY
F100
STORAGE/ EQUIP.
F105
CONTROL DESK/
SUPPORT STAFF
F102
VIEWING AREA
F114A
CORRIDOR
F109A
CORRIDOR
F107A
CORRIDOR
F101A
ENTRY/ LOBBY
F101
10' - 0"
10' - 0"
10' - 0"
20' - 0"
8' - 0"
10' - 0"
12' - 0"
16' - 0"108
10' - 0"
12' - 0" 10' - 0" 12' - 0"
16' - 0"
16' - 0"
12' - 0" 12' - 0"
112112
112112
112112
123123
A-511
C3
6' - 0" 25' - 9" 6' - 0"
6' - 0" 19' - 0" 6' - 0" 28' - 0" 6' - 0" 7' - 4"
10' - 0"
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
A-111A
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A K
.F E
L T
O N
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
SCALE : 1/8" = 1'-0"A1 REFLECTED CEILING PLAN - AREA A
BAY GBAY F
KEY PLAN
A
0 8' 16' 32'
GRAPHIC SCALE
PLAN NORTH
REFERENCE KEYNOTES:
108 EXPOSED STRUCTURE ABOVE. PAINT ALL EXPOSED
STRUCTURE AND PIPES.
112 BID OPTION: SUSPENDED CEILING CLOUD W/MESH
123 4'-0" X 8'-0" CEMENTITIOUS WOOD FIBER
ACOUSTICAL CEILING PANELS ATTACHED AT
EXISTING STEEL PURLINS. SEE DETAIL C1/A-511
133 2'-0"X 2'-0" ACCESS PANEL. SEE DETAIL A1/A-511
147 LARGE VOLUME FANS. SEE MECHANICAL DWGS.
AND STRUCTURAL DWGS.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .