A-101B FLOOR PLAN -AREA B.pdf

PDF 317 KB Posted

Attached to
DLA Fitness Center Renovation Federal contract opportunity
Solicitation number
1430
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This floor plan drawing depicts proposed renovations to the fitness center located at Defense Supply Center Richmond. Key details include layout of new and existing rooms such as men's and women's locker rooms, showers, saunas, and mechanical and storage spaces. Renovations will include new lockers, mirrors, bulletin boards, and fire extinguisher cabinets. The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Norfolk seeking contractors to complete the DLA Fitness Center Renovation project with a solicitation number of 1430 and posted on April 13, 2020.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Fitness Center Renovation, newest first.
File Type Posted
A-111B REFLECTED CEILING PLAN -AREA B.pdf PDF
A-101C FLOOR PLAN -AREA C.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
Section 11 66 23 Gymnasium Equipment.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
Section 09 65 00 Resilient Flooring.pdf PDF
H.01.01_Convert B32, Bays F-G for Fitness Center_RTA_Drawings_22Nov19.pdf PDF
Section 09 65 66 Resiliend Athletic Flooring.pdf PDF
Section 09 68 00 Carpet Tiles.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
W91236-20-B-2011 Fitness Center.pdf PDF
A-512 ROOF DETAILS.pdf PDF
A-111A REFLECTED CEILING PLAN -AREA A.pdf PDF
A-121 OVERALL ROOF PLAN.pdf PDF
A-521 MISCELLANEOUS DETAILS.pdf PDF
Section 08 14 00 Wood Doors.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111C ELECTRICAL DEMOLITION PLAN -AREA C.pdf PDF
A-111D REFLECTED CEILING PLAN -AREA D.pdf PDF
A-201 BUILDING ELEVATIONS.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
A-111C REFLECTED CEILING PLAN -AREA C.pdf PDF
H.01.04_Convert B32, Bays F-G for Fitness Center_RTA_Specifications_22Nov19.pdf PDF
Section 09 51 00 Acoustical Ceiling.pdf PDF
118ECE908 RTA FF and E Binder 22Nov19.pdf PDF
Section 09 64 66 Wood Athletic Flooring.pdf PDF
Section 09 30 10 Porcelain Tiling.pdf PDF
Lead Based Paint Survey Report Building No. 32.pdf PDF
Section 12 66 00 Telescoping Stands.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D1

A-301

D1

A-301

1 2 3 4 5 6 7

H

I

J

89 SF

EXISTING

TELECOM

F117

100 SF

JANITOR

F118

132 SF

LAUNDRY

F1191271 SF

BREEZEWAY

F100

716 SF

WOMEN LOCKER

F116C

993 SF

MEN LOCKER

F115C

48 SF

STEAM

F116D29 SF

MECH.

F116E

34 SF

MECH.

F115E

48 SF

STEAM

F115D

76 SF

SAUNA

F115B

F117

F118

F119

F B

F E

F E

F116AF115A

F

E 288 SF

CORRIDOR

F101B

P2

P2A

P2C

P2AP2A

P2B

P1

P1

F D

F D

9' - 2" 93' - 9" 7' - 2" 9' - 5"

F C

F C

396 SF

MEN RESTROOM

F115A

289 SF

WOMEN

RESTROOM

F116A

182 SF

WOMEN SHOWERS

F116F

346 SF

MEN SHOWERS

F115F

F B

F B

75 SF

SAUNA

F116B

114114 114114

A-404

D3

A-401

D1

DN

DN

DN

P1

A2

A-312

130 130

154154

105105

105105

155155

105105

155155

105105

A.

B.

C.

D.

E.

REFER TO SHEET A-002 FOR PARTITION TYPES

AND TYPICAL DETAILS.

ALL DIMENSIONS ARE FACE OF MASONRY OR FACE

OF METAL STUD.

PAINT ALL EXPOSED STEEL STRUCTURE.

PROVIDE WALL REINFORCING AT ALL WALL HUNG

CASEWORK, FIXTURES, SPECIALTY EQUIPMENT,

BALLET BARRE, MARKER/DISPLAY BOARDS AND

SHELVES, REFER TO TYPICAL PARTITION DETAILS,

BACKING PLATE DETAILS.

ALL INTERIOR DOORS SHALL HAVE HINGE SIDE

DIMENSION FROM INTERSECTING PARTITION TO

DOOR FRAME EDGE OF 4" AT GYPSUM

PARTITIONS, TYP. U.N.O

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

A-101B

F L O

O R

P L A

N

A R

E A

B K

.F E

L T

O N

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

BAY GBAY F

KEY PLAN

B

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

REFERENCE KEYNOTES:

GENERAL NOTES:

101 ELECTRIC WATER COOLER

103 WASHER/DRYER N.I.C.

105 TWO TIERED, 12"W X 12"D X 72"H Z-LOCKERS ON 4"

CONCRETE BASE

114 4'-0" X 7'-0" MIRRORS MOUNTED AT 24" A.F.F, SEE

INTERIOR ELEVATIONS AND DETAIL D5/A-521

130 SEMI RECESSED FIRE EXTINGUISHER CABINET,

SEE DETAIL D4/A-521

138 ENCLOSED BULLETIN BOARD. SEE INTERIOR

DWGS.

148 ALIGN FACE OF WALL FINISH TO EXISTING

149 INFILL EXISTING OPENING W/ 4" CMU BACKER AND

SALVAGED BRICK TO MATCH EXISTING.

153 PATCH/REPAIR MTL. STUD FURRING AND GYP. BD.

AROUND COLUMNS AS NECESSARY, TYP.

154 POWER ASSIST PUSH BUTTON. SEE ELECTRICAL

DWGS.

155 SECURE LOCKERS TO CONCRETE BASE W/

UNISTRUT CHANNEL. REFER TO STRUCTURAL

DETAIL A3/S-501

SCALE : 1/8" = 1'-0"A1 FLOOR PLAN - AREA B