This floor plan drawing depicts proposed renovations to the fitness center located at Defense Supply Center Richmond. Key details include layout of new and existing rooms such as men's and women's locker rooms, showers, saunas, and mechanical and storage spaces. Renovations will include new lockers, mirrors, bulletin boards, and fire extinguisher cabinets. The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Norfolk seeking contractors to complete the DLA Fitness Center Renovation project with a solicitation number of 1430 and posted on April 13, 2020.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D1
A-301
D1
A-301
1 2 3 4 5 6 7
H
I
J
89 SF
EXISTING
TELECOM
F117
100 SF
JANITOR
F118
132 SF
LAUNDRY
F1191271 SF
BREEZEWAY
F100
716 SF
WOMEN LOCKER
F116C
993 SF
MEN LOCKER
F115C
48 SF
STEAM
F116D29 SF
MECH.
F116E
34 SF
MECH.
F115E
48 SF
STEAM
F115D
76 SF
SAUNA
F115B
F117
F118
F119
F B
F E
F E
F116AF115A
F
E 288 SF
CORRIDOR
F101B
P2
P2A
P2C
P2AP2A
P2B
P1
P1
F D
F D
9' - 2" 93' - 9" 7' - 2" 9' - 5"
F C
F C
396 SF
MEN RESTROOM
F115A
289 SF
WOMEN
RESTROOM
F116A
182 SF
WOMEN SHOWERS
F116F
346 SF
MEN SHOWERS
F115F
F B
F B
75 SF
SAUNA
F116B
114114 114114
A-404
D3
A-401
D1
DN
DN
DN
P1
A2
A-312
130 130
154154
105105
105105
155155
105105
155155
105105
A.
B.
C.
D.
E.
REFER TO SHEET A-002 FOR PARTITION TYPES
AND TYPICAL DETAILS.
ALL DIMENSIONS ARE FACE OF MASONRY OR FACE
OF METAL STUD.
PAINT ALL EXPOSED STEEL STRUCTURE.
PROVIDE WALL REINFORCING AT ALL WALL HUNG
CASEWORK, FIXTURES, SPECIALTY EQUIPMENT,
BALLET BARRE, MARKER/DISPLAY BOARDS AND
SHELVES, REFER TO TYPICAL PARTITION DETAILS,
BACKING PLATE DETAILS.
ALL INTERIOR DOORS SHALL HAVE HINGE SIDE
DIMENSION FROM INTERSECTING PARTITION TO
DOOR FRAME EDGE OF 4" AT GYPSUM
PARTITIONS, TYP. U.N.O
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
A-101B
F L O
O R
P L A
N
A R
E A
B K
.F E
L T
O N
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
BAY GBAY F
KEY PLAN
B
4'0 8' 16'
GRAPHIC SCALE
PLAN NORTH
REFERENCE KEYNOTES:
GENERAL NOTES:
101 ELECTRIC WATER COOLER
103 WASHER/DRYER N.I.C.
105 TWO TIERED, 12"W X 12"D X 72"H Z-LOCKERS ON 4"
CONCRETE BASE
114 4'-0" X 7'-0" MIRRORS MOUNTED AT 24" A.F.F, SEE
INTERIOR ELEVATIONS AND DETAIL D5/A-521
130 SEMI RECESSED FIRE EXTINGUISHER CABINET,
SEE DETAIL D4/A-521
138 ENCLOSED BULLETIN BOARD. SEE INTERIOR
DWGS.
148 ALIGN FACE OF WALL FINISH TO EXISTING
149 INFILL EXISTING OPENING W/ 4" CMU BACKER AND
SALVAGED BRICK TO MATCH EXISTING.
153 PATCH/REPAIR MTL. STUD FURRING AND GYP. BD.
AROUND COLUMNS AS NECESSARY, TYP.
154 POWER ASSIST PUSH BUTTON. SEE ELECTRICAL
DWGS.
155 SECURE LOCKERS TO CONCRETE BASE W/
UNISTRUT CHANNEL. REFER TO STRUCTURAL
DETAIL A3/S-501
SCALE : 1/8" = 1'-0"A1 FLOOR PLAN - AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .