About this file
This reflected ceiling plan drawing and related federal contract opportunity solicitation provide details for renovations to the fitness center at the Defense Supply Center Richmond in Virginia. The reflected ceiling plan drawing shows the existing ceiling layout and proposed changes for Area B of the fitness center, including new ceiling materials, lighting fixtures, ventilation components, and other ceiling-mounted elements. The related solicitation under number 1430 seeks contractors to complete the fitness center renovations, with responses due by April 13, 2020. The Department of the Army Corps of Engineers Engineering District Norfolk will serve as the contracting agency. Renovations are needed to convert existing building space to modernize the fitness center for staff at the Defense Supply Center Richmond.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
C
C
C
C
ET ET
C
C
C
C
C
C
C
C
C
C
C
C
1 2 3 4 5 6 7
H
I
J
EXISTING
TELECOM
F117
JANITOR
F118
LAUNDRY
F119
BREEZEWAY
F100
SAUNA
F116B
WOMEN LOCKER
F116C
MEN LOCKER
F115C
STEAM
F116D
MECH.
F116E
MECH.
F115E
STEAM
F115D
SAUNA
F115B
CORRIDOR
F101A
CORRIDOR
F101B
8' - 0"
8' - 0" 8' - 0"
8' - 0"
10' - 0"
10' - 0"
106 106
WOMEN
RESTROOM
F116AMEN RESTROOM
F115A
MEN SHOWERS
F115F
WOMEN SHOWERS
F116F
10' - 0" 10' - 0"
10' - 0"
10' - 0"
REFLECTED CEILING LEGEND
EXIT LIGHT - CEILING
2' x 2' SUSPENDED
ACOUSTIC CEILING TILES
GYPSUM BOARD CEILING
2 X 4 LIGHT FIXTURE
SUSPENDED LIGHT FIXTURE
RETURN AIR GRILLE
SUPPLY AIR GRILLE
EXHAUST AIR GRILLE
CEILING HEIGHT TAG
SD
S
SMOKE DETECTOR
SPEAKER
8'-0"
2' x 2' SUSPENDED
CEILING CLOUD W/MESH
STROBE
WOOD CEILING
4' X 8' CEMENTITIOUS
WOOD FIBER ACOUSTICAL
CEILING PANELS
1 X 4 LIGHT FIXTURE
RECESSED LIGHT FIXTURE
RECESSED DOWN LIGHT
CERAMIC TILE CEILING
CEILING FAN
4X8 T&G CEILING PANEL
A. CENTER CEILING GRID IN ROOM UNLESS SHOWN
OTHERWISE ON REFLECTED CEILING PLAN.
B. CENTER FIXTURES, MECHANICAL DIFFUSERS,
MECHANICAL GRILLES AND SPRINKLER HEADS IN
SUSPENDED ACOUSTICAL CEILING TILE SYSTEM
PANELS.
C. ALL CEILING MOUNTED ITEMS ARE SHOWN FOR
COORDINATION PURPOSES ONLY.
D. SEE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE
AND SPECIAL SYSTEM TYPES.
E. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND
GRILLE TYPES.
F. SEE FIRE PROTECTION FOR SPRINKLER TYPES.
SEE TELECOMMUNICATION AND FIRE PROTECTION
SYSTEMS FOR ADDITIONAL INFORMATION OF
CEILING MOUNTED DEVICES.
G. ALL RCP DIMENSIONS ARE CLEAR FINISHED
DIMENSIONS, UNLESS OTHERWISE NOTED.
H. REFER TO FINISH SCHEDULE FOR CEILING TYPES
AND HEIGHTS NOT INDICATED ON THE REFLECTED
CEILING PLANS.
I. ALL GYPSUM BOARD CEILING WITHIN 4'-0" OF
PERIMETER SHALL BE MOISTURE RESISTANT.
J. SMOKE AND HEAT DETECTORS TO BE GREATER
THAN 3'-0" FROM MECHANICAL DIFFUSERS.
RCP GENERAL NOTES:
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
A-111B
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B K
.F E
L T
O N
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
SCALE : 1/8" = 1'-0"A1 REFLECTED CEILING PLAN - AREA B
BAY GBAY F
KEY PLAN
B
REFERENCE KEYNOTES:
106 GYPSUM BOARD BULKHEAD, REFER TO CEILING
DETAILS
108 EXPOSED STRUCTURE ABOVE. PAINT ALL EXPOSED
STRUCTURE AND PIPES.
133 2'-0"X 2'-0" ACCESS PANEL. SEE DETAIL A1/A-511
0 8' 16' 32'
GRAPHIC SCALE
PLAN NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .