About this file

This floor finish plan and related federal contract opportunity document provide details for renovating the fitness center at the Defense Supply Center Richmond in Virginia. The floor finish plan outlines the existing layout and proposed renovations to areas within the fitness center, including new flooring types and finishes.

The related federal contract opportunity is solicitation number 1430 posted on April 13, 2020 by the Department of the Army Corps of Engineers Engineering District Norfolk. The solicitation is for renovating the DLA Fitness Center and will include work such as installing new flooring, as outlined in the floor finish plan. Interested contractors should respond by the dates provided to be considered for this contract award. The renovation work appears focused on upgrading and replacing existing flooring and finishes within the fitness center spaces.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Fitness Center Renovation, newest first.
File Type Posted
A-111B REFLECTED CEILING PLAN -AREA B.pdf PDF
A-101C FLOOR PLAN -AREA C.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
Section 11 66 23 Gymnasium Equipment.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
Section 09 65 00 Resilient Flooring.pdf PDF
H.01.01_Convert B32, Bays F-G for Fitness Center_RTA_Drawings_22Nov19.pdf PDF
Section 09 65 66 Resiliend Athletic Flooring.pdf PDF
Section 09 68 00 Carpet Tiles.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
W91236-20-B-2011 Fitness Center.pdf PDF
A-512 ROOF DETAILS.pdf PDF
A-111A REFLECTED CEILING PLAN -AREA A.pdf PDF
A-121 OVERALL ROOF PLAN.pdf PDF
A-521 MISCELLANEOUS DETAILS.pdf PDF
Section 08 14 00 Wood Doors.pdf PDF
ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111C ELECTRICAL DEMOLITION PLAN -AREA C.pdf PDF
A-111D REFLECTED CEILING PLAN -AREA D.pdf PDF
A-201 BUILDING ELEVATIONS.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
A-111C REFLECTED CEILING PLAN -AREA C.pdf PDF
A-101B FLOOR PLAN -AREA B.pdf PDF
H.01.04_Convert B32, Bays F-G for Fitness Center_RTA_Specifications_22Nov19.pdf PDF
Section 09 51 00 Acoustical Ceiling.pdf PDF
118ECE908 RTA FF and E Binder 22Nov19.pdf PDF
Section 09 64 66 Wood Athletic Flooring.pdf PDF
Section 09 30 10 Porcelain Tiling.pdf PDF
Lead Based Paint Survey Report Building No. 32.pdf PDF
Section 12 66 00 Telescoping Stands.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1779 SF

EXISTING BOILER

ROOM

G113

110 SF

EXISTING

TELECOM

G110

440 SF

EXISTING

MECHANICAL

G108

113 SF

EXISTING

ELECTRICAL

G107

632 SF

STORAGE

G106

7010 SF

GYMNASIUM

G111

260 SF

WOMEN

G116

262 SF

MEN

G118

42 SF

JAN.

G117

698 SF

THERAPY AREA

G121

141 SF

STORAGE

G119

233 SF

RELAXATION

ROOM

G123

118 SF

PERSONAL

TRAINER

G124

230 SF

RELAXATION

ROOM

G122

140 SF

STORAGE

G120

799 SF

MECHANICAL

G114

1751 SF

CORRIDOR

G112

101 SF

VESTIBULE

G115

170 SF

CORR.

G121A

187 SF

STORAGE

G109

45 SF

EXISTING RISER

ROOM

G125

62 SF

EXISTING RISER

ROOM

G126

28 SF

MECH

G127

119' - 5 7/8"

MECH

G128

FLOOR FINISH LEGEND

ART-1

CPT-1

LVT-1

PC-1

PT-1

SC-1

TRF-1

WDF-1

WDF-2

P -4

P -3

P-3

P-3

P -3

P-3

P-3

P-3

TS-13

TS-3 TS-14

I-401

A1

TS-6

TS-6

WS-1WS-1 WS-1 WS-1 WS-1

V.I.F.

3' - 6"

V.I.F.

3' - 6"

V.I.F.

3' - 6"

V.I.F.

3' - 6"

A. REFERENCE ARCHITECTURAL FLOOR PLANS FOR FLOOR

RAMP TRANSITIONS. SEE KEYNOTE 128.

B. REFERENCE SHEET I-601 FOR INTERIOR FINISH LEGEND,

SCHEDULE AND DETAILS.

C. MATCH FINISH OF COVERS FOR RETURN AIR DUCTS, VENTS, &

REGISTERS IN DRYWALL CEILINGS AND WALLS TO ADJACENT

SURFACES.

D. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL

SURFACES, OPERATING PARTS, OR LABELS.

E. FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF

DOOR, UNLESS NOTED OTHERWISE.

F. RESTROOM SHOWERS ARE PRECAST UNITS. SEE FINISH

LEGEND, I-601.

G. WINDOW SILLS TO BE SS-2.

H. BULLNOSE ALL EXPOSED EDGES AND OUTSIDE CORNERS OF

WALL TILE AND BASE.

I. INSIDE MOUNT WS-1 ON ALL INTERIOR WINDOWS. ALL

WINDOWS SHALL RECEIVE SHADES.

J. SLOPE TILED FLOORS TO FLOOR DRAINS AS REQUIRED.

FINISH PLAN GENERAL NOTES:

ACCENT WALL LEGEND

P-X ACCENT WALL PAINT LOCATION

WITH PAINT COLOR CODE. SEE

FINISH LEGEND FOR PAINT COLOR

INFORMATION.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

I101C

F L O

O R

F

IN

IS

H

P L A

N

A R

E A

C K

.B A

R K

E R

C .C

O L E

B .F

O R

E T

B .F

O R

E T

SCALE : 1/8" = 1'-0"A1 FLOOR FINISH PLAN - AREA C

PLAN NORTH

4'0 8' 16'

BAY GBAY F

KEY PLAN

C

TS-5 TS-5TS-10